Home

LMP-0600 Series

image

Contents

1. 22 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 5 1 ERPS Status Below Figure 5 18 shows the network redundancy ring status with the Ethernet Ring Protection Switch ERPS protocol ERPS Status ERPS Status Protocol Disable Ring ID 1 Ring State Mormal Mode State INITIAL STATE Channel 1000 Revertiwe Enable Figure 5 18 Redundant Ring Network ERPS Status 5 5 2 ERPS Configuration Below Figure 5 19 shows the ERPS configuration interface ERPS Configuration ERPS Configure Protocol Ring Port 0 Role Ring Port 1 Role Ring ID Channel Revertive Figure 5 19 ERPS Configuration Interface 23 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Value Description Enable or Disable ERPS protocol ERPS ring port 0 it could be map to real switch port 1 port 6 Ring Port 0 Do not set the same as Ring port 1 Ring Port1 ERPS ring port 1 it could be map to real switch port 1 port 6 Do not set the same as Ring port 0 Set the ERPS role as Owner Neighbor or Normal Owner In charge of blocking one side of RPL link It will prevent the packet flow from its blocked port Neighbor In charge of blocking one side of RPL link It will prevent the packet flow from its blocked port Normal Besides Owner and Neighbor node the rest of nodes are defined as Normal node All node roles have the ability to bl
2. www antaira com support antaira com www antaira eu info antaira eu www antaira com tw info antaira com tw 72
3. 6 N Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 show snmp trap host show snmp trap version show snmp trap community show snmp trap inform retry show snmp trap v3 user show snmp trap v3 level show snmp trap v3 engine ID show snmp trap v3 auth show snmp trap v3 encryption LD 2 O LD 2 3 O tr Ta Di O 3 ha O 3 3 D O c mE Q O O lt wa c ech ech Q O o e G mi c Ke Q O 2 FILE O O O lt o e Q m C O O O gt zm C gt O O both port_list 3 O 3 a O A o D 0 ct 5 G ct O 5 Q D 0 e O O 3 3 o D c PORT MIRROR show monitor enable show monitor source qos map cos priority type to tx queue queue s map dscp priority type to tx queue queue qos trust cos dscp type type show qos queue schedule show qos map cos priority type show qos map dscp priority type 313 O o 2 2 m e O o om lo OI c Q el EI oO 0 x SE S lt Ss Ps 5 1 O ojo sic 1 O IO IO IOIO Q O O zi O IO o o la lalalo ololololola al Z 2 2 ololo o oi coc cls E Sem OQ C33 29 9 T o ELE olcia EIE o ls O lolo o9 4 oo 9 ze Q 0 01 6 Ol DI Ol gt 5 n o 5 lo n IC Io O 9 joj D o E T o ES os o Ol sI lo woe 5 Ps D O et O lt S 5 lt a o c em ES Ss S a E O show qos trust
4. Endspan MDI X Alternative A Port Interface RS232 Serial 1 RS232 in RJ45 connector with console cable 115 2Kbps Console 8 N 1 Configuration Backup 1 USB 2 0 72 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Power Reverse Polarity Present the unit will not be on if power reverse 10Base T 2 pair UTP STP Cat 3 4 5 cable 100Base TX 2 Network Cable pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m Per Unit Power 1 Green Power 2 Green Fault Red PoE Feeding Power Green LED Indicator Mechanical Metal IP30 protection uid A sewer 1 removable 6 contact terminal block 25W 48VDC per PoE port 30W 51 55VDC per PoE ort Power Consumption 10 Watts no PD included 130 Watts Fully loaded Operating STD 10 to 70 C 14 to 158 F EOT 40 to 75 C 40 to Temperature 167 F Storage Temperature 40 C 85 C 40 F 185 F Ambient Relative Requirement PoE Power Output Environmental Limits Humidity 5 to 95 non condensing CE EN6100 4 2 3 4 5 6 8 CE EN6100 6 2 EN6100 6 4 Regulatory IEC60068 2 32 Free fall Stability Testing IEC60068 2 27 Shock IEC60068 2 6 Vibration Table 7 1 LMP 0600 Series Technical Specification Approvals Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira
5. JE 3181813 21212 3135 O o S m m is I o lo lo lld O O O O O gt 5 5 S l Sl l al ee oO Oo LS eal 0 0 03 S oh 2130 3 3 35 2 E 3 l3 23 E EIS I zs c Es o Sys E See o0 39 on m 3 53 5 CHE Sic SR z a je ja Sig S 2 D amp G G ct o MES 2 213 3 t O ole a 3 Po DIN ae oO lt o ioja on zy O c O lt Z O 3 a S Nal E O C Ge lt D m O o 2 c o D spanning tree priority priority value g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 interface interface interface interface interface interface interface configure configure interface interface interface interface interface interface interface configure configure configure configure configure configure OD N Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 spanning tree forward time forward time spanning tree hello time hello_time zu spanning tree max age max age spanning tree cost link cost value spanning tree port priority port priority spanning tree link type point to point point to multiple spanning tree auto edge off spanning tree admin edge on spanning tree stp disable no spanning tree enable no spanning tree mode no spanning tree priority no spanning tree forward time no spanning tree hello time no spanning tree max age STP no spanning tree mst instance ID priority no spanning tree cost no spanning tree port prior
6. MAC Table Mask Maintenance Gateway gt Configuration DNS Server gt Logout Speed Duplex Tx Byte PoE Rx Byte Figure 5 2 Web Console Main Status Page 5 2 Basic Setting 5 2 1 System Information Below Figure 5 3 shows the switch system setting information System SWITCH SETTING System Name System Description 6 port Managed PoE Ethernet Switch EA AA System Location System Contact Figure 5 3 Switch Settings Status Page 14 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Factory Default Switch User can assign any name label to identify this managed node By convention a domain name is a text string drawn from the System Name alphabet A Z a z digits 0 9 minus sign No space characters are permitted as part of a name The first character must be an alpha character And the first or last character must not be a minus sign The allowed string length is O to 255 Factory Default 6 port Managed PoE Ethernet Switch System Description User can assign any new name label to describe this PoE Managed Switch Factory Default blank User can use this field to insert The physical location of this System Location switch e g telephone closet 3rd floor The maximum allowed string length is O to 255 and the allowed content is the ASCII characters from 32 to 126 Factory Default blank User can insert this field with the administrator
7. Normal T Ring ID Channel Revertive lt D i a Figure 5 26 Non Configured Architecture Setup 5 6 Spanning Tree The Spanning Tree Protocol STP defined in the IEEE Standard 802 1d can be created within a mesh network of connected layer 2 switches The Rapid Spanning Tree Protocol RSTP defined in the IEEE 802 1w RSTP is an enhanced solution of STP It shares most of its basic operation characteristics and essentially creates a cascading effect away from the root bridge where each designated bridge proposes to its neighbors to determine if it can make a rapid transition Another extension of RSTP is the Multiple Spanning Tree protocol MSTP defined in the IEEE802 1s It allows different VLANs to travel along separate instances of spanning tree Unlike STP and RSTP MSTP eliminates the needs for having different STP for each VLAN Therefore in a large networking environment that employs many VLANs MSTP can be more useful than legacy STP 30 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 6 1 RSTP Status Figure 5 27 shows the RSTP algorithm results RSTP CIST Status Root Status Bridge ID 8 000 7C CB 0D AD DC 14 Path State Port Cost Ce Oper Edge Figure 5 27 RSTP Information Interface 5 6 2 RSTP Configuration Users can enable disable the RSTP function and set the parameters for each port RSTP CIST Configuration Mode Root Priority R
8. event syslog cold start enable event syslog warm start enable o o DE mox O O z z D D lt lt OD OD gt gt m em o o 3 3 m em LO OH D a S i A 3 Q O D O T DI e O gt m D gt O D CH Z gt Z m T O o O z 3 h o E pmj D D 2 Di EE D D lt D 5 tr o lt Si O O o C tr 3 D 5 O oi ct O 3 event syslog erps change enable D lt D o lt ux O O zi D D O O z m JJ TI gt O m Z 2 lt m fe oO o O z 2 2 O O D D lt lt D D E eme cr o o lt lt Glo O O Q Q O o O O zz D D CS N 2 O lt to 2 mE o lt e O O Q o EN o e D a o p Q ba O D lt er o lt D O O o ER 3 h E D 2 O D lt D 3 tr GC lt o O Q o C mn gt D 5 O A ct O 5 2 O ad lt Lem o lt o O O D wa o ys my D 2 bd show event syslog power Event show event syslog power2 show event syslog cold start show event syslog warm start show event syslog erps change event alarm power1 enable event alarm power2 enable show event alarm power show event alarm power2 show event alarm interface INTERFACE NAME up down event apply J 15 o iq o 09 D 9191012 2 2 Oo 29 2 3 2 SX AE uge D D 2 o lv lo 3 5 wn S lalai SE
9. 2 O O Q O 0 e OQ O 0 e lt Y ALA e D D 3 o mt o e D 2 O D g CH O O Si O mt lt y gt O gt t lt t D D 3 LI F D 3 D 5 O o O QD 2 5 Q STP gt gt D D olololo o 09 o 09 O lololo oOicoio o D D mD 2 gt 2 2 2 gt gt gt D IO lalala rt e e F o lo lio lo o lo lolo 3 3 3 3 o o 09 o e e e gt D D a lt NETTE 3131319 9 90 3 U O 0O ld ham D O o oO o a 3 2 0 Lo l o LI gt lt lt G gt D D 3j o ech Q 3 D D D 3 o ech D lt o O 2 o o o 2 2 o O O O 3 3 o o o OO OH D Q D 2 2 2 a ela 2 2 2 O Q Q D D 3 o 5 o Q 2 O D zi o D D O D AZ lt D 5 olo Su O O 2 oio LO LO Q Q 51 5 212 5 25 O O D D D D 3 3 o 0 m em dJ oo m em D D 3 CS O o A G MU CH OH O x Me C lt o 2 O o O D 2 2 2 d D D 3 o rmt 3 o e D 2 O D 5 CH O I O m O Si mt lt D D lt lt D D 2 2 e em o o 33 e al OD oo oO oo O O zz D D En N D D 2 2 D D Oc D D Se lt to 2 E o 3 e 5 Q o e o e S a 2 D e D D lt D 2 o 3 O Q 3 1 o Q ba D ems Q e D Sl s ololo
10. BE 47 542 9 SMTP Sets 48 Sed Event eN leidos 49 9 12 5 FUA EE 49 DIS MAC Ke EE EEN 50 5 1941 MAGO Address E iii Ai 50 5 13 2 MAC Table CGontguraton eese 50 MEDIE Eege o1 9 14 1 Elie e EEN 51 E ROD 52 SN RE lloc Un 52 SS ele le 61 10 EE 52 oW jes ci AR Po er ee 53 5 1512 Ele le OO sida 53 Delo AUTO Ee LEE GE 54 neie E NO 54 6 Command Line Interface Management 55 6 1 About GLI Management eret edet edet dex 55 7 Technical Specifications e nenen enen 72 vi Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 1 Introduction All Antaira industrial managed switches come with a pre installed user friendly web console interface which allows users to easily configure and manage the units whether one is using a serial console and command line interface CLI commands like Telnet SSH HTTP Web GUI or simple network management protocols SNMP 1 1 Product Overview Antaira s LMP 0600 series is a 6 port industrial POE managed Ethernet switch that is IEEE 802 3at complaint power over Ethernet plus and is embedded with four 10 100Tx Ethernet ports that support either IEEE802 3af or IEEE802 3at for a maximum of 30 watts per port and two 10 100Tx Fast Ethernet ports It is a fully manageable industrial Ethernet switch that supports the standard Layer 2 Ethernet configurable settings This product series i
11. Ee e 24V dc 14 Resistance Figure 2 8 Wiring the Fault Alarm Contact Note e The wire gauge for the terminal block should range between 12 24AWG Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 3 Mounting Installation 3 1 DIN Rail Mounting The DIN Rail is pre installed on the Rear Panel ofthe switch industrial Ethernet switch from the factory If the DIN Rail is not on the industrial Ethernet switch please see Figure 3 1 to DIN Rail learn how to install the DIN Rail on the switch The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch 1 Use the screws to install the DIN Hal bracket on the rear side of the industrial Ethernet switch 2 Toremove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure 3 2 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 Check if the bracket is mounted tightly on the rail To remove the industrial Ethernet switch from the rail do the opposite from the above steps Figure 3 2 Figure 3 3 Insert the Switch on the DIN Hai Stable the Switch on DIN Rail Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 3 2 Wall Mounting Follow the steps below to mount the industrial
12. Reg om o 2 S919192 lt lt ke Ss o a 8 S o a O O a ta 2 vo zzsg D 0 5 D D pL Qjo LO O l Ml sch IF D gt D bo gt O D kd a 5 z m E 3 JU E e Z 3 m TI gt Z O m D a 3 o ZU O m Z 2 E m gt Z O D gt m m lt lt Ee Z m 2 T E i S m E E c 2 3 iz o z o E 2 3 gt syslog server IP address configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure O O1 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 SYSLOG no syslog mode show syslog server show syslog mode show syslog log smtp enable smtp sender E MAIL_ADDR smtp subject subject text JE O 1 o w O n O o3 alo N IQ MO O lt oO 06 m 5 D 3 O e D o O v o O o D lt D RV o e D o o zZ gt E COD Z U OD TI JJ lt TI E 0 o Io SSS SS zs 77 0 2 3 3 O o jo lio jolo O O 3 3 3 2 2 oo loloa lolo o o s s O J Legs e 3 o o o D D O O O O OI O O S C D S 2 gt gt Iio Io lo io no o
13. Ts ne occas sciatic Ra RE 10 SNB DE HR Oe de Le E 10 S22 VV GI e tt elsa lolas 11 4 Hardware InsStallatlO E 12 A stallauonm les EE 12 5 Web Management eee 13 5 1 Web Console Configuration eee eee eee eee eee 13 5 1 1 About Web based Management 13 5 2 DasiG MMM 14 32 OY SIM NO IMAN AS 14 9 22 o Tl EN Se o 15 SS PNE 16 SS o o T T ent 17 5 3 Port Management 18 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 dl en dr iaa 18 30 2 PORN CONNU Neee a tddi 18 5 4 PoE Power over Ethernet sees eee eee ee eee 19 SA d POE ee le Teran TT 19 e WAC AIT EE 20 549 POE SCN COUN C oca 21 Seen 22 A n cae ecu ee aaro Lee UMS uU 23 o5 2 ERPS GOODIIgUIallOl iia 23 Ee Ein ulee 30 ASA A oo HA 31 5 6 2 RSTP Configuration sees eee nennen pn nem enne erase Earn ds 31 A 33 5 6 4 MS T GontigurallOfis esto 34 SW OLI MAN Em 36 b V802 TO VLAN SAS ioca achete Dam do e E UA UIS 36 5 7 2 902 10 VLAN SEINO uan Eos 37 5 8 GIMP SNOODING iei tette oe AS 37 Se MIRAS AOS ros 38 5 8 2 IGMP Snooping status Table E 39 59005 Trafic Prorntizatoi teclea 39 59 E Ee ME E 40 9x OS EE 41 599 TOS E ee e E 42 SAN AAA PP rhc cantielgaiateisGnnele Guinean 43 AS A IA 44 V Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 NEIE sta Ee 44 5 1 1 2 SNMP Frap Seting stat tds 45 A ne DE 46 9 12 RT Tele SC linia daran 46 5 12 2 System EVENT LOO
14. developing new functions and features for specific application requirements for the industrial managed switches Users can download the latest firmware from Antaira s website and store it within their local PC server or USB drive Upgrade FIRMWARE UPGRADE Image Choose File Mo file chosen USB FIRMWARE UPGRADE Image Figure 5 62 Firmware Upgrade Interface Users can click the Choose File button to select the latest FIRMWARE UPGRADE firmware from the local PC or Server then click the Upgrade button to have the switch be updated USB FIRMWARE Fill in the folder and filename and click the button of UPGRADE Upgrade If the folder or filename does not exist system will return error If it succeeds system will reboot Ex file1 folder file2 Figure 5 63 Firmware Upgrade Setting Terms amp Value Description 91 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 14 2 Reboot Users can click the Apply button under the Reboot interface to reboot the switch Reboot Reboots the operating system of your device Figure 5 64 Switch Reboot Interface 5 14 3 Default Users can reset the switch to Factory Default by clicking the Apply button under the default interface Reset Factory Default Reset factory default of your device Figure 5 65 Reset Factory Default Interface 5 15 Configuration Under the Configuration section
15. first managed switch and set it up as the RPL neighbor node For configuration users should login to the switch s second managed ERPS configuration interface and choose a specific port number under Ring Port 0 and set it as the Normal node by clicking the dropdown box of Role then set another specific port number under Ring Port 1 as the Neighbor node as shown below in Figure 5 23 So the link between neighbor port and owner port forms the ring protection link RPL After the configurations press the Apply button on the bottom right corner to save the settings Note The port number of Ring Port 0 and Ring Port 1 cannot be duplicated 26 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 ERPS Configuration ERPS Configure Protocol Ring Port 0 Role Normal Ring Port 1 Role Ring ID Channel Revertive Figure 5 28 RPL Neighbor Node Setup Example Normal Node Then user should setup the rest of the managed switches Role of both Ring Port O and 1 as Normal Node as shown above in Figure 5 23 Please be sure no duplicate port number has been chosen within a managed switch s ERPS ring setting the incorrect configurations may lead to unexpected errors 27 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 ERPS Configuration ERPS Configure Protocol Ring Port 0 Role Ring Port 1 Role Ring ID Ch
16. for wall mounting installation To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section Power on the industrial Ethernet switch and then the power LED light will turn on e f you need help on how to wire power please refer to the Wiring the Power Inputs section e Please refer to the LED Indicators section for LED light indication Prepare the twisted pair straight through category 5 cable for Ethernet connection Insert one side of the RJ 45 cable into switch s Ethernet port and on the other side into the networking device s Ethernet port e g switch PC or server The Ethernet port s RJ 45 LED on the industrial Ethernet switch will turn on when the cable is connected to the networking device e Please refer to the LED Indicators section for LED light indication When all connections are set and the LED lights all show normal the installation is complete 12 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 Web Management 5 1 Web Console Configuration This section introduces the configuration by web browser 5 1 1 About Web Based Management All of Antaira s industrial managed switches are embedded with HTML web console interfaces that have a flash memory on the CPU board It is a user friendly design with advanced management features that allow users to manage the switch from anywhere on the network through any Internet browser such as Inter
17. network performance find and solve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP 5 11 1 SNMP Agent SNMP Agent SNIMP Enable SNMP Read Only Community Read and Write Community Appl Figure 5 49 SNMP Agent Setup Interface Terms Value Description Enable SNMP Enable SNMP function by check the box Read only Community User can release the SNMP to public for read only Apply Click Apply button to save changes Figure 5 50 SNMP Agent Interface Terms amp Value Description 44 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 11 2 SNMP Trap setting Trap Setting SNMP Enable SMMP Trap Trap Destination IP Community public Figure 5 51 SNMP Trap Setting Enable SNMP Trap Enable SNMP Trap function by check the box User could insert the Server IP address as Trap Trap Destination IP Destination IP info User can release the SNMP to public for read only Appl Click Apply button to save changes Figure 5 52 SNMP Trap Settings Terms amp Value Description 45 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 12 System Warning System warning function is very important for managing a switch Users can manage the switch by Syslog System Event Log and Email
18. saha o c m d Q e D o lt O c md D addr string oO 3 D LI D lt D zR G 2 O JO O O tr D O o rb o O Lo 2 O O Q D y G E e e Sp e D RV lt 2 O o gt D 3 D o D lt my show boot host dhcp show ip address LI 2 O 2 oO o D j D e Q e D o lt show ip name server show ip mode addr_string Time no ntp sync day lia ria la ee a li E e eee SS al E 0 SO O EE eI I 2 2 2 2 2 2 0 o o o o o Rl Rola SSS S S 328 8 5 55 S S S 2l0 7 7 3 lt A A EE ER 1 OO ee A EE 2 3 31333 00 3 3 2 3713290 gt lo S cojas o 312 2 a a 8 2 1 gt 1 8 3 53 8 3 2 3 2 8 lt lo 2L 2 2 2 0 23 5 0 2 9 o SO O 3 a2a mi 2 sziu o 0 0 2 E lem 5 e Em ECKE EE rt o o 5 Q0 0 96 U 3Z3 S373 0 23 73 0 2 5 2 GE 010 3 2 end ECH EA EA EECH m 3 a 2 e 371 5 D A Io 112 3 o S o MES d D 3 O e lt b configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure C1 CLO Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V
19. users can save all the settings that have been configured backed up and stored to a local PC Server or a USB storage device through the built in USB port Users can use the USB port feature to execute the Auto Load function to boot the switch s configuration that has been saved within the USB storage device or users can utilize this function to Auto Load the configuration to other switches and those switches would require the same configuration settings Users can keep the USB storage device plugged in with the switch to enable the USB Auto Backup function to allow the switch s configuration settings to backup to the USB storage device whenever users makes and save configuration settings 92 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 15 1 Save Users can click the Save button under the SAVE CONFIGURATION interface once all the settings have been configured Save SAWE CONFIGURATION Save Configuration Figure 5 66 Save Setting Interface 5 15 2 Backup amp Store Backup amp Restore CONFIGURATION MANAGEMENT Backup Configuration Backup Upload Configuration Choose File No file chosen USB MANAGEMENT Save Running Config To USE 1 1 1 1 1 1 4 Save Startup Config To USB 11 11 1 11 Upload Config From USB Fe Figure 5 67 Backup amp Restore Setting Interface Terms Value Description CONFIGURATION MANAGEMNET By c
20. 1 0 flowcontrol lt receive gt on off desired interface name string interface shutdown interface no speed interface no duplex interface interface no name interface no shutdown interface show speed interface show duplex interface interface interface show name interface interface interface interface show duplex interface show link rx interface show link tx interface interface interface vlan J 10 o o IO O o o 2 G 2 2O 2 2 2 2 35 O 3 090 0 O IOIO O IO Si o IS IS ZS lt lt i O UN 7 L h sg 2 2 2 8 2 8 DO 2 l 1 0 G loi o 23 13 o fe O I ae gt Oo 51 10 o 2 9 a 5 O D 0 23 Dio lt de Sp 3 Q gr G o 25 2 L Kb DIS 3 D o O D lt D member member_portlist lt untag_portlist gt vlan O gt O Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 vlan mode port tag ging configure vlan group group num group portlist configure switchport pvid vlan id interface interface switchport provider interface o i I e O Sg a gt D CS D O O D es 2 P S O O D Q interface o ech O O O m D y D m lt O D 0 3 D lt O Dd no name vlan no member vlan no vlan mode configure no vlan group configure interface VLAN interface interface interface show name vlan show member vlan show vlan mode configure show vl
21. 3 F D o GEMENG 5 D D D D lagi SE l3 les Z lt oO lo lt SIS co 0o0 o o oc Or E e o a gt o FNAS legs SI D 9 Ka D D O D T ct D 53 15 2 O0 OQ QO O Q O O lt os V VZJ 5 5 o VS D o m a ob a M oe dl ie eh Q 3 Q O O wlo c o P 3 ela 5l9 p S ol C 3 a S 2 3 3 O c S IE Sele O oio alo C x 3 lt O gt c Es U 2 a O DD e Lo smtp server port GMAIL SMPT SERVER smtp authentication username GMAIL ACCOUNT smtp receive 1 2 3 4 e mail address SMTP no smtp subject show smtp state show smtp sender show smtp subject show smtp server address show smtp server port show smtp receive 1 2 3 4 snmp server enable lt v1 v2c only v3 only gt snmp server community ro rw community_name configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure OD O Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 snmp server v3 auth admin user md5 sha PWD snmp server v3 encryption admin user des aes no snm
22. 4 3 PoE Schedule For energy saving or power recycle powered devices the PoE managed switch s PoE schedule interface allows users to appoint any date and time to enable or disable PoE functions for each POE port PoE SCHEDULE Porti Monday Enable Start time hour End time hour Tuesday Enable Start time hour End time hour Wednesday Enable Start time hour End time hour Thursday Enable Start time hour Power over Ethernet Ch X CH kb Figure 5 17 PoE Schedule Interface 21 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 5 ERPS In any industrial automation application designing the redundant ring network paths can protect networks from unexpected failovers is extremely important in mission critical networks that need to provide uninterrupted services In practice several loop protection methods are implemented to ensure that network functions normally without loops and recovers as soon as possible when a point of failure occurs The most popular ones are RSTP 802 1w and MSTP 802 1s For industrial applications the ERPS G 8032 are highly recommended since they can achieve faster recovery time than any STP protocol Due to different manufacturers who provide their own proprietary redundant ring protocol and users facing inconvenient situations with compatible issues when they are planning to design or upgrade their ring network for future proof Antaira is p
23. Assignments Note and signs represent the polarity of the wires that make up each wire pair All ports on this industrial Ethernet switch support automatic MDI MDI X operation Users can use straight through cables see figure below for all network connections to PCs servers other switches or hubs With straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below Table 2 3 shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Signal Name MDI Signal Name Receive Data plus RD Transmit Data plus TD Receive Data minus RD Transmit Data minus TD Transmit Data plus TD Receive Data plus RD Transmit Data minus TD Receive Data minus RD Table 2 3 Ethernet Signal Pin Outs The following figures show the cabling schematics for straight through and crossover Switch Router or PC Switch Switch 3 TD4 3 RD 3 TD 3 TD 6 TD 6 RD 6 TD 6 TD Mra Th l RDF 1 Ki 2 RD 2 TD 2 RD 2 RD Figure 2 4 Figure 2 5 otraight Through Cable Schematic Crossover Cable Schematic Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 2 6 Cabling El Twisted pair segments can be connected with an unshielded twisted pair UTP or shielded twisted pair STP cable The cable must comply with the IEEE 802 3u 100Base TX stand
24. DC power inputs 48 55VDC FNRE 2 Fam PWR EN Frame Ground Figure2 3 Top Panel View of LMP 0600 Series Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 2 4 LED Indicators There are LED light indicators located on the front panel of the industrial Ethernet switch that display the power status and network status Each LED indicator has a different color and has its own specific meaning see below in Table 2 f Powerinput1is active P1 Green EE X Powerinput1isinactive 2 Powerinput2is active Green of Powerinput2isinactive Eu System is ready System is booting Green Fault Fault Alarm ER System is in normal state Green Connected to network 10 100Mbps p ai 6 E Networking is active e Off Not connected to network po 1 on me port is supplying power to the powered device PoE Indicators Nr No powered device attached or power supplying fails Table 2 1 LED Indicators for LMP 0600 Series 2 5 Ethernet Ports B RJ 45 Ports RJ 45 Ports Auto MDI MDIX The RJ 45 ports are auto sensing for 10Base T 100Base TX connections Auto MDI MDIX means that the switch can connect to another switch or workstation without changing the straight through or crossover cabling See the figures below for straight through and crossover cabling schematics Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 pa RJ 45 Pin Assignments Table 2 2 Table 2 2 RJ45 Pin
25. Ethernet switch using the wall mounting bracket as shown below in Figure 3 4 l 2 9 4 Remove the DIN Rail bracket from the industrial Ethernet switch by loosening the screws Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall To remove the wall mount bracket do the opposite from the steps above Figure 3 4 Remove DIN Rail Bracket from the Switch Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounting Bracket Dimensions 11 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 4 Hardware Installation 4 1 Installation Steps This section will explain how to install Antaira s LMP 0600 series 6 port industrial POE managed Ethernet switch with 4 10 100Tx 30W Port RJ45 ports and 2 10 100Tx RJ45 ports Installation Steps 1 2 Unpack the industrial Ethernet switch from the original packing box Check if the DIN Rail bracket is screwed onto the industrial Ethernet switch e If the DIN Rail is not screwed on the industrial Ethernet switch please refer to the DIN Rail Mounting section for DIN Rail installation e f you want to wall mount the industrial Ethernet switch please refer to the Wall Mounting section
26. Owner Node Node Normal Normal Node node Normal Normal node Node Figure 5 21 RPL Configured Architecture RPL Owner Node There is only one RPL owner node that is required to be setup within a redundant ring network Users have to decide on one managed switch as the ring protection link RPL owner then login to the ERPS configuration interface and choose a specific port number under Ring Port 0 and set it as Owner node by clicking the dropdown box of Role Then users can set another specific port number under Ring Port 1 as Normal node The configurations are shown below in Figure 5 22 Note The port number of Ring Port 0 and Ring Port 1 cannot be duplicated 25 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 ERPS Configuration ERPS Configure Protocol Enable Ring Port 0 Port1 Role Owner Ring Port 1 H x E Role Normal Ring ID Channel 1000 Revertive lt Im tn EI Figure 5 22 RPL Owner Node Setup Example By selecting Yes under the Revertive mode the ring will recover the ring s state from ABNORMAL to NORMAL within 5 minutes Otherwise the blocked port will remain blocked permanently until the user re configures it After the configurations press the Apply button on the bottom right corner to save the settings RPL Neighbor Node Users should choose a second managed switch that is adjacent to the
27. S F 8 Oo lo Sisi 2 o lo lo gt D I E 9 a o50 ol o 2121 el olv Lad e 3 O O l et l a l C TES l S512172 SI IE D O vo lm ie SS US M l ka l a o e ES r ES gt mio gt ba o O Iz gt lolsS O D m D 5 z Q gt o Z D m C O o O gt 2 O D lt D e o 3 mon o Q Q S o em ni 2 O D lt D o 3 O D 3 1 o D Event o y O D lt D 2 o 3 O O o Ke o Q ba o DE O D lt D 2 o 3 O D 3 1 o Q m Q loiilo5i5il25 ee e Ie se Dico qc dd 2 4E 0 9 15151 o i 7 5 la 1V o o a od E A 3 oio 3 3 090 0 0 gt I gt 3 019 C o ela ls elel i2 3 zz 9 0 5 x VOD Io le N 2 23 90 FIOS 3 9 3 m a JJ f gt 3 O O Ke Z gt lt JI C LO o O gt configure configure configure configure interface interface configure configure configure interface interface configure configure configure configure interface interface configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure O ER Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 show event smtp erps change event syslog power1 enable event syslog power2 enable
28. Server setup for Advanced Notice in any event type Event Type Selection and Fault Alarm setting By setting up all these system warning features users will receive the in advanced warning message through email whenever any event occurs It definitely increases the flexibility and capability for the user to monitor the remote site network and device statuses 5 12 1 Syslog Setting The SYSLOG is a protocol to transmit event notification messages across networks Syslog Setting SYSLOG SYSLOG Mode Disable Y SYSLOG Server IP Address Disable Local Only Remote Only USB Only All Figure 5 53 Syslog Setting Disable Disable SYSLOG Local Only Log to local system Remote Only Log to a remote SYSLOG server USB Only Log and store SYSLOG data and warning file to USB storage device through built SYSLOG Mode in USB Port and the file name is message All Log to all local server USB port and remote SYSLOG server at the same time Notice that there is one log in local server or USB port If USB presented it will log to USB storage Otherwise it logs to local server Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 SYSLOG Server IP Address Insert remote SYSLOG server IP address Click Apply button to save changes Figure 5 54 SYSLOG Setting Terms amp Value Description 5 12 2 System Event Log Users can view and display the syste
29. an group configure show switchport pvid interface interface interface interface g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 98032 enable disable aps channel channel ID revertive clear portO interface interface name port1 interface interface name o 2 3 ow 5 o d r o gt D gt o 5 a ololo O Io lollo E o dr N o a 2 S lt lt lt lt 3 lt ae 3 o d r o ech ek gt D e E esse S ISI DES em e geb O 010 10 O lo lolo o O FoS ee O o IOJO o Oo O Oo lei Isi B S S IS 2 g a gt O oco Ki O ct a Ee A S Dei lt lo D o O Is lt 10 D Eu KE gt D O 2 o O Sen o timer hold off time timer guard time O Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 timer wtr time no portO no port1 no ring id 5 3 3 O O O 312 3 lt o ILZ D O lE 1 kee DIS oO e A G OD O Se wesch 5 O 3 D s o q O gt power inline auto power inline never power inline delay power inline apply power inline max watts power inline status power inline power supply watts show power inline show power inline priority show power inline max show power inline status show power inline power supply spanning tree enable spanning tree mode rstp mst olco 3is3l3 Te O oloioi535 l5 38 SE 31313123 e cr
30. annel Revertive Figure 5 24 RPL Normal Node Setup Example 5 5 2 2 Scenario B Non Configured Architecture In some situations users can choose not to configure the RPL owner and neighbor node the ERPS could still work well under the mechanism by blocking one of the ring ports in the ERPS ring topology 28 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Blocked port Normal Node Normal Node Normal Normal Node Node Normal vreg Node Figure 5 25 Non Configured Architecture As shown above in Figure 5 25 the ERPS is blocked at one of the ring node ports The blocked port is chosen by an election mechanism that is decided by the MAC address Because the MAC address is unique the ERPS will just choose the biggest MAC as the blocking node However the user is still required to enable the RRPS protocol and assign a dedicated port number for each uplink port under Ring Port O and 1 but there is no requirement to setting the role Figure 5 26 below shows the configurations as a reference After the configurations press the Apply button on the bottom right corner to save the settings Note The port number of Ring Port 0 and Ring Port 1 cannot be duplicated 29 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 ERPS Configuration ERPS Confi jure Protocol Enable Ring Port 0 Don Role Normal M Ring Port 1 Port Role
31. antalra LMP 0600 Series 6 Port Industrial PoE Managed Ethernet Switches 4 10 100Tx 30W Port 2 10 100Tx 48 55VDC Power Input oa deae User Manual Version 1 0 Antara www antaira com Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Copyright 2014 Antaira Technologies LLC All Rights Reserved This document contains information which is protected by copyright Reproduction adaptation or translation without prior permission is prohibited except as allowed under the copyright laws Trademark Information Antaira is a registered trademark of Antaira Technologies LLC Microsoft Windows and the Windows logo are the trademarks of Microsoft Corp NetWare is the registered trademark of Novell Inc WMM and WPA are the registered trademarks of Wi Fi Alliance All other brand and product names are trademarks or registered trademarks of their respective owners Notice Copyrights O 2014 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Antaira Technologies LLC may make improvements and or changes to the product and or specific
32. ard e g Category 5 5e or 6 The cable between the equipment and the link partner switch hub workstation etc must be less than 100 meters 328 ft long E Fiber segments using a single mode connector type must use a 9 125um single mode fiber cable E Fiber segments using a multi mode connector type must use a 50 or 62 5 125 um multi mode fiber cable 2 7 Wiring the Power Inputs Please follow the steps below to insert the power wire 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 6 V1 V1 V2 V2 Figure 2 6 Power Terminal Block 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 7 Figure 2 7 Power Terminal Block Note e Only use copper conductors 60 75 C tighten to 5Ibs e The wire gauge for the terminal block should range between 18 20 AWG Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 2 8 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as the picture shows below in Figure 2 8 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and forma normally open circuit An application example for the fault alarm contact is shown below in Figure 2 8 INL SH Sg PWR2 p fee a la Te
33. ations of the product described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are periodically made to the information contained herein and will be incorporated into later versions of the manual The information contained is subject to change without prior notice Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy lt may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Heorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the rec
34. b or all E Telnet 192168 2 198 User Access Verification Username admin Password SWES gt en SWESH configure terminal SHES lt config syslog mode all remote local ush SWES conf ig syslog mode all SUES Cconfigd syslog mode usb SHEStconfigH Select USB or ALL it can auto save waning file to USB And the file name is message 6 CLl enable configure terminal gt usb auto load enable 7 CLI enable gt configure terminal gt usb auto load enable 71 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 7 Technical Specifications Table 7 1 below has the technical specifications for Antaira s LMP 0600 series 6 port industrial PoE managed Ethernet switch with 4 10 100Tx 30W Port RJ45 ports and 2 10 100Tx RJ45 ports 10Base T 10Mbit s Ethernet ITU TG 8032 Y 1344 ERPS Ethernet Ring Protection Switch QoS CoS Protocol for Traffic Prioritization CSMA CD IGMPv1 v2 SNMPv1 v2 TFTP SNTP SMTP RARP Protocol Syslog 14 880 pps for 10Base T Ethernet port Transfer Rate 148 800 pps for 100Base TX Fast Ethernet port Packet Buffer 1Mbits Jumbo Frame IEEE 802 3x for full duplex mode back pressure for half duplex Flow Control mode VLAN Groups 0 4094 IGMP Groups Up to 256 6 10 100Tx 4 PSE 30W Port auto negotiation speed Full Half Ethernet RJ45 Port duplex mode and auto MDI MDI X connection PoE Pin Assignment V V V V for pin 1 2 3 6
35. configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure interface interface configure configure configure interface interface configure configure configure interface O 00 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 igmp snooping enable igmp snooping query max respond time second igmp snooping last member count time igmp snooping query interval second igmp snooping last member interval second Save and Load Configuration File to from USB 1 CLI enable gt configure terminal gt copy running config usb path EN Telnet 192 168 2 19 User Access Verification Username admin Password SWES 3 en SWESH configure terminal SWES config copy running config startup config usb SWES Cconfig gt copy running conf iy startup config usb SWES Cconfig gt copy running config usb filel SWES Cconfigd copy running config usb testrfileZ SWESiconfigH Fill in the folder and filename behind the copy running config usb command Ex file1 folder file2 69 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 2 CLl enable gt configure terminal gt copy startup config usb path EN Telnet 192 168 219 User Access Verification User
36. e Querier Enable Query Interval s 125 OOOO Query Max Response Time s Figure 5 38 IGMP Snooping Settings Interface IGMP Protocol Check the box to enable or disable IGMP Snooping Switch will be IGMP querier or not There should have the existing one and only one IGMP querier in an IGMP application up to 256 Groups The frequency at which the querier sends query Query Interval messages Query Max Response Time The maximum response time advertised Click Apply button to save changes Figure 5 39 IGMP Snooping Settings Terms amp Value Description 38 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 8 2 IGMP Snooping Status Table Multicast filtering is the system by which end stations only receive multicast traffic if they register to join specific multicast groups With multicast filtering network devices only forward multicast traffic to the ports that are connected to registered end stations IGMP Snooping Table IGMP SNOOPING TABLE oos MERE 239 0 0 1 239 0 0 2 el EE Figure 5 40 IGMP Snooping Status Table 5 9 QoS Traffic Prioritization Network traffic is always unpredictable and the only basic assurance that can be offered is the best effort traffic delivery To overcome this challenge Quality of Service QoS is applied throughout the network This ensures that network traffic is prioritized according to specified criteria and receives preferen
37. e network is using If DHCP client function is enabling user does not require assigning the IP address The network DHCP server will assign the IP address for the switch and it will be display in this column 16 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Assign the subnet mask of the IP address If DHCP client function is enabling user does not require to assign the subnet mask Gateway Assign the network gateway for the switch If DHCP client function is enabling user does not require to assign the Gateway DNS Assign the DNS IP address Click Apply button to save changes Figure 5 8 IP Setting Information Description 5 2 4 System Time System Time NTP Local Time Sat Feb 26 02 22 48 2000 Select Your Time Zone UTC Enable NTP Client Time Server Figure 5 9 System Time Settings l User can define the switch s local time or click Sync with Local Time browser button to have local time setup automatically User can use dropdown box to setup the switch location time Select Your Time Zone zone Enable or disable NTP function to get the time from the SNTP Enable NTP Client server User can define the time server info Click Apply button to save changes Figure 5 10 System Time Settings Description 17 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 3 Port Management 5 3 1 Port Status The following inf
38. eiver is connected e Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications not expressly approved by the grantee of this device could void the user s authority to operate the equipment CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Industrial Ethernet Switches Industrial Grade Gigabit Unmanaged Ethernet Switches User Manual Version 1 0 September 2014 This manual supports the following models e LMP 0600 e LMP 0600 T This document is the current official release manual Please check our website www antaira com for any updated manual or contact us by e mail supportWantaira com Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Table of Contents LES Tu de Sro e errar 1 AA EE 1 1 2 Product Software Features siria 1 1 3 Product Hardware Features 2 1 4 Package COnientS a nan ance 2 to Sale Precaution ida 3 2 Hardware Description css sssssssssssss sss esssssses enesenn ennenen nenen eee d 2 1 PNysical DIMENSION L 4 2 2 FIOM D La 5 2 9 TOP Mito 5 2 4 D RE te ee TE 6 Z 481 5 9 5 Ol gt OPERA PROPER E PRE EE ED a cem tam EEUU 6 A 8 2 7 Wiring the Power INputs oocccocccoccoccnccocccncnonanononnonononanonanonnnos 8 2 8 Wiring the Fault Alarm Contact 9 3 MOUNUNG B
39. from USB to Switch And the file name is switch MAC ADDRESS cfg if the file didn t exist it will find switch config cfg If all of them didn t USB Auto Load exist it does not work Select USB Auto Backup it can auto Backup running config file USB Auto Backup from Switch to USB And the file name is startup config Figure 5 70 USB Auto Load amp Backup Setting Terms amp Value Description 5 16 Logout Users can logout of the web console interface by pointing at and clicking logout from the menu 94 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 6 Command Line Interface Management 6 1 About CLI Management Besides WEB based management LMP 0600 series also supports CLI management Users can use console or telnet to manage the switch by CLI CLI Management by RS 232 Serial Console 115200 8 none 1 none Before configuring by an RS 232 serial console use an RJ45 to DB9 F cable to connect the switches RS 232 console port to the PC s COM port Follow the steps below to access the console via RS 232 serial cable Step 1 From the Windows desktop click on Start gt Programs gt Accessories gt Communications gt Hyper Terminal amp Accessibility im Communications d HyperTerminal Le Network Time Protocol Network and Dial up Connections Le System Tools d amp HyperTerminal A Acrobat Reader 5 0 Address Book E Calculator EN C
40. ftware Upgrade via TFTP and HTTP Configuration Backup USB Port 1 3 Product Hardware Features B System Interface and Performance e All RJ 45 ports support auto MDI MDI X function e Embedded 4 10 100Tx PSE 30W Port RJ45 Ports and 2 10 100Tx Fast Ethernet ports e Store and forward switching architecture e 8K MAC address table e Power line EFT protection 2 000VDC Ethernet ESD protection 6 000VDC B Power Input e DC 48 55V redundant with a 6 pin removal terminal block e One user programmable alarm relay contact B Operating Temperature e Standard operating temperature models 10 C to 70 C e Extended operating temperature models 40 C to 75 C NW Case Installation e P 30 protection metal housing e Installation in pollution degree to environment e DIN Rail and wall mount design 1 4 Package Contents B 1 LMP 0600 series 6 port industrial PoE managed Ethernet switch with 4 10 100Tx 30W Port RJ45 Ports and 2 10 100Tx Fast Ethernet ports B 1 Product CD 2 W all mounting brackets and screws M 1 RJ45 to DB9 Serial Console Cable Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 M 1 DC cable 18 AWG DC jack 5 5x2 1mm 1 5 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this
41. ial Ethernet Switches LMP 0600 Series User Manual V1 0 Apply Click Apply button to save changes Figure 5 32 MSTI Configuration Terms amp Value Description MSTI PORT Figure 5 33 MSTI Port Configuration Interface Users can select Instance Tab 1 15 to configure each Instance Tabs o MSTI port Cost amp Priority value Users can define the path cost value from 1 through 200000000 to the other bridge from this transmitting bridge at the specified port Users can decide which port should be blocked by priority in LAN by select the value from 0 to 240 from the dropdown box Click Apply button to save changes Figure 5 34 MSTI Port Configuration Terms amp Value Description 35 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 7 802 1Q VLAN A Virtual LAN VLAN is a logical network grouping that limits the broadcast domain which allows user to isolate network traffic Only the members of the VLAN will receive traffic from the same members of VLAN Basically creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still plugged into the same switch physically The switch supports port based and 802 1Q tagged based VLAN The default configuration of VLAN operation mode is at 802 1Q 5 7 1 802 1Q VLAN Settings Tagged based VLAN is an IEEE 802 1Q s
42. iority in LAN The value of priority must be the multiple of 16 Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only be connected to exactly one other switch i e It is served by a point to point LAN segment Admin P2P or it can be connected to two or more switches i e It is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True means P2P enabling False means P2P disabling The port is directly connected to end stations and it Auto Edge cannot create bridging loop in the network To configure the port as an edge port set the port to True 32 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 The port includes the STP mathematic calculation Admin Non STP True is not including STP mathematic calculation False is including the STP mathematic calculation Click Apply button to save changes Figure 5 29 RSTP Configuration Terms amp Value Description MSTP Multiple Spanning Tree Protocol It is defined in IEEE 802 1s it can map a group of VLAN s into a single multiple spanning tree instance MSTI In fact the spanning tree protocol is applied separately for a set of VLAN s instead of the whole network Different root switches and different STP parameters can be individually configured for each MSTI So one link can be active for one MSTI a
43. ity no spanning tree link type no spanning tree auto edge no spanning tree admin edge no spanning tree admin edge no spanning tree stp show spanning tree mode show spanning tree priority show spanning tree forward time show spanning tree hello time show spanning tree max age show spanning tree cost show spanning tree port priority show spanning tree link type show spanning tree auto edge show spanning tree admin edge show spanning tree stp spanning tree mst instance ID priority priority configure configure configure interface interface interface interface interface interface configure configure configure configure configure configure configure interface interface interface interface interface interface interface configure configure configure configure configure interface interface interface interface interface interface configure 6 CO Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 N Wn O oO D 2 5 ux EA 2 DS SE dE SE D o zj 3 om a 3 2 1 0 O dd irs Il S m lt lt m GE O Z 77 O D gt 5 2 Q t D D 0 e 5 G e G gt O D 5 gl e Di 2 O D lt D 5 lt Y 3 _9rp ity number o O Q D 2 D D 3 o ech o D 2 O D Ke O O Em ech lt O E O I o o O O og gt 3 3 3 gt a do t D D 3 0 e dE 0 e
44. licking the Backup button it allows users to back Backup Configuration up the switch configuration setting to local PC or Server User can click the Choose File button to select the Upload Configuration mE saved configuration file from local PC or server then 53 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 MA click the Upload the settings to the switch USB Management Fill in the folder and filename and click the button of Save Running Config to USB Backup If the folder or filename does not exist system will generate it automatically Ex file1 folder file2 Fill in the folder and filename and click the button of Backup Because startup file didn t exist in default it Save Startup Config to USB will be error to save in default If the folder or filename does not exist system will generate it automatically Ex file1 folder file2 Fill in the folder and filename and click the button of Upload If the folder or filename does not exist system Upload Config from USB will return error If it succeeds system will reboot Ex file1 folder file2 Figure 5 68 Backup amp Restore Setting Terms amp Value Description 5 15 3 Auto Load amp Backup USB Auto Load and Backup Auto Load and Backup USB Auto Load USB Auto Backup Figure 5 69 USB Auto Load amp Backup Setting Interface Select USB Auto Load it can auto load startup file
45. lue Description 5 8 IGMP Snooping The Internet Group Management Protocol IGMP is a communications protocol used to manage the membership of Internet Protocol multicast groups IGMP is used by IP hosts and adjacent multicast routers to establish multicast group memberships When IGMP snooping is enabled in a switch it analyzes all the IGMP packets between hosts connected to the switch and multicast routers in the network When a switch receives an IGMP report for a given multicast group from a host the switch adds the host s port number to the multicast list for that group When the switch hears an IGMP leave it removes the host s port from the table entry IGMP snooping can reduce multicast traffic from streaming and other bandwidth intensive IP applications more effectively A switch using IGMP snooping will only forward multicast traffic to 37 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 the hosts in that traffic This reduction of multicast traffic reduces the packet processing at the switch at the cost of needing additional memory to handle the multicast tables and also decreases the workload at the end hosts since their network cards or operating system will not receive and filter all the multicast traffic generated in the network IGMP has 3 versions IGMP v1 v2 and v3 and support query group up to 256 groups 5 8 1 IGMP Settings ing Configuration IGMP SNOOPING IGMP Snooping Enabl
46. m event log by clicking the Apply button on the right bottom corner of the interface Then the system event logs will display within the SYSLOG LIST window The SYSLOG LIST will contain up to 5 pages of system event log information Users also can click the Refresh button to have the most updated system event logs information to display System Event Log SYSLOG LIST Refresh Figure 5 55 System Event Logs Interface 47 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 12 3 SMTP Setting The Simple Mail Transfer Protocol SMTP is for e mail transmission across the Internet SMTP Setting SMTP E mail Alert Disable T SMTP Server Address Sender E mail Address Mail Subject Authentication Username Password Recipient E mail Address 2 Recipient E mail Address 3 tC bo bo bo Recipient E mail Address 1 Ir E L L L Recipient E mail Address 4 Figure 5 56 SMTP Setting Interface E mail Aen Enable Disable transmission system warning events by e mail SMTP Server Address Setting up the mail server IP address Sender E mail oet up the email account to send the alert Address Mail Subject The subject of the mail Check the box to enable the Authentication function Authentication Username the authentication username Password the authentication password Recipient E mail User can setup up to 4 recipient E mail addresses to receive Add
47. name admin Password SWES gt en SWESH configure terminal MES config copy running config startup config usb SuESCconfig i copy startup conf ig runningy config usb SHESiconfig copy startup config usb filel SHES lt config copy startup config usb testrfileZ SuUESCconfig H m Fill in the folder and filename behind the copy startup config usb command Ex file1 folder file2 3 CLl enable gt configure terminal gt copy usb startup config path E Telnet 192168 2 18 User Access Verification Username admin Password SHES gt en SHESH configure terminal SWES Cconfig copy running config startup config usb SWES Cconfig gt copy usb startup config firmware SHES lt config copy usb startup conf ig destination file firmare destination file SHES config copy usb startup config filel Fill in the folder and filename behind the copy usb startup config command Ex file1 folder file2 70 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 4 CLI enable gt configure terminal gt copy usb firmware path ER Telnet 192 168 219 User Access Verification Username admin Password GUEST en SWESH configure terminal SHES Cconfig gt H copy usb firmware file Fill in the folder and filename behind the copy usb startup config command Ex file1 folder file2 5 CLI enable gt configure terminal gt Syslog mode us
48. nd the other link active for the second MSTI This enables some degree of load balancing and generally two MSTI s are used in the network for easier implementation 5 6 3 MSTI Status Users can display the MSTI root status and port status by selecting the instance ID number from 1 to 15 by clicking on the dropdown box from the MSTI Status interface MSTI Status Instance ID 1 v Root Status Figure 5 30 MSTI Status Interface 33 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 6 4 MSTI Configuration Users can display the MSTI root status and port status by selecting the Instance ID number from 1 to 15 by clicking on the dropdown box from the MSTI Status interface MSTI Configuration Revision 0 65535 Instance Instance Priority 32788 Figure 5 31 MSTI Configuration Interface Users can insert the unique MAC address of the bridge switch Revision Users can insert the value from 0 65535 MTSI Instance Instance No amp VLAN There are 1 15 instance number user can insert which Group VLAN Group info into the belonging Instance number A value used to identify the root bridge The bridge with the lowest value has the highest priority and is selected as the root Priority 0 61440 The switch is required to reboot when there s any value change The value must be multiple of 4096 according to the protocol standard rule 34 Antaira Industr
49. ne z Restore Defaults Disconnected Auto detect Auto detect E ICAPS MIN otep 5 The console login screen will appear Use the keyboard to enter the Username and Password and then press Enter User Access Verification Username admin Password SWES gt en SWESH configure terminal CLI Management by Telnet Users can use TELNET to configure the switches The default value is as below B IP Address 192 168 1 254 Subnet Mask 255 255 255 0 B Default Gateway none B User Name admin B Password admin 57 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Follow the steps below to access the console via Telnet Step 1 Telnet to the IP address of the switch from the Windows Run command as shown below PS EE Type the name of a program folder document or Internet resource and Windows will open it For vou Open telnet 192 168 10 1 Cancel Browse Step 2 The login screen will appear Use the keyboard to enter the Username and Password and then press Enter User Access Verification sername admin Password SWES gt en SWESH configure terminal Commander Groups eme mmm Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 show environment power 2 show environment temperature admin username admin admin password admin boot host dhcp ip address ip addr ip mask oO o D
50. net Explorer version 9 0 or above is recommended Firefox Chrome and many others Preparing for Web Console Configuration Antaira s industrial managed switches come with a factory default value as below M Default IP Address 192 168 1 254 NW Default User Name admin NW Default Password admin System Login 1 Launch any Internet browser 2 Type in factory default IP address http 192 168 1 254 of the switch Press Enter Sa http 192 168 1 254 cgi bin luci D G switch Gantalra making connectivity simple Model name LMX 0600 IP Address 192 168 1 254 MAC 7C CB 0D B2 9A DD Firmware Version 2 2 3 Authorization Required Please enter your username and password Figure 5 1 Web Console Login 13 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 The login screen appears Key in the default username admin and password admin Click Login button then the main status page of the web console will appear as below in Figure 5 2 The online image of the switch will display the real time ports connection status cR proa G Status Switch w Model name LMX 0600 IP Address 192 168 1 254 MAC 7C CB 0D B2 9A DD Firmware Version 2 2 3 Status antaira Basic Settings gt Port Management gt Status Spanning Tree IGMP Snooping Ip gt 802 1Q VLAN EE kii MAC gt O irroring gt SNMP geg gt System Warning pm gt
51. ock the port if the link attach to the port is failed and disconnected ERPS ring ID ranges from 1 to 239 Ring ID distinguishes different Ring topology ERPS Channel ID ranges from 1 to 4094 It s a channel to send PDUs of ERPS Revertive Set to Revertive yes or Non revertive no The revertive mode works only under the scenario A atthe RPL Owner node Revertive While the revertive mode is set the RPL link will be blocked in 5 minutes after recovery form link failure situation Otherwise it will remain unchanged of the blocking state That is the failed link port will block permanently until the next event happen Non Revertive The failed ring link the port attached to it will remain blocked even the situation is eliminated Click Apply button to save changes Figure 5 20 ERPS Configuration Terms amp Description Below there are two scenarios describing how to configure the ERPS in the managed switches Users can configure the redundant ring network either as the RPL configured architecture Figure 5 21 or as a non configured architecture Figure 5 22 24 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 5 2 1 Scenario A RPL configured Architecture Under this scenario A there are three major roles that are required in order to be configured within the ERPS configuration RPL ring port neighbor RPL ring port owner RPL Ring Protection Link RPL Neighbor
52. of this switch System Contact together with information on how to contact this person The maximum allowed string length is O to 255 and the allowed content is the ASCII characters from 32 to 126 Click Apply button to save changes Figure 5 4 Switch Settings Description 5 2 2 Admin amp Password Below describes how to configure the system s user name and password for the web console login Admin Password ADMINISTRATIVE ACCOUNT Figure 5 5 Administrative Account 15 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 New Password User can assign a New Password and the maximum allow string length is O to 31 characters Re type the new password Apply Click Apply to save changes Figure 5 6 Admin amp Password description 5 2 3 IP Setting Configure the managed switch IP setting information IP Setting IP CONFIGURATION DHCP Client IP Address Subnet Mask Gateway DNS Figure 5 7 IP Setting information Terms Value Description DHCP Client Enable the DHCP client by checking this box If DHCP fails and the configured IP address is zero DHCP will retry If DHCP fails and the configured IP address is non zero DHCP will stop and the configured IP settings will be used The DHCP client will announce the configured System Name as hostname to provide DNS lookup IP Address The unit default IP is 192 168 1 254 Assign the IP address that th
53. ommand Prompt CH NetTime a Notepad ki Paint y Windows Explorer Ka Accessories IEY WordPad 5 Network Associates gt LS Startup K Z Internet Explorer d Outlook Express 55 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Step 2 Input a name for the new connection Ts New Connection HyperTerminal Bl x File Edit View Call Transfer Help Dias ela ol e SS Connection Description 2 xi w New Connection Enter a name and choose an icon for the connection Name ha Disconnected Auto detect Auto detect SCROLL CAPS NUM Capture Print echo A Step 3 Select to use a certain COM port number termnial HyperTerminal R z D xj File Edit View Cal Transfer Help Dis ez ola l B termnial Enter details for the phone number that you want to dial Country region Taiwan 888 y Area code Pp Phone number O Connect using Cancel See Disconnected Auto detect Auto detect SCROLL CAPS NUM Capture Print echo 96 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Step 4 The COM port properties settings should be as follows 115200 for Bits per second 8 for Data bits none for Parity 1 for Stop bits and none for Flow control prm ioj x L Port Settings Bits per second ux0 y Data bits sl Parity None D Stop bits 1 Flow control No
54. oot Hello Time Root Forward Delay Root MHaxinium Age Admin Non STP Admin P2P Auto Edge 31 Figure 5 28 RSTP Configuration Interface Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 User can select RSTP or MSTP function to be enabled or ae A value used to identify the root bridge The bridge with the lowest value has the highest priority and is selected as Root Priority 0 61440 the root lf any change of the value the switch is required to be reboot The value must be multiple of 4096 according to the protocol standard rule Enter a value between 1 through 10 for the time to control Root Hello Time 1 10 the switch to send out the BPDU packet for RSTP current status checking Enter a value between 4 through 30 as the number of Root Forward Delay 4 30 seconds for a port to wait before changing from its RSTP learning and listening states to the forwarding state Enter a value between 6 through 40 as the number of Root Maximum Age seconds a bridge waits without receiving STP 6 40 configuration messages before attempting a reconfiguration Enter a value from 1 through 200000000 to define the path cost for the other switch from this transmitting switch Path Cost 0 200000000 7 at the specified port When path cost insert in 0 the switches will be setup as automatic data transmitting Enter a number 0 through 240 to decide which port should Priority 0 240 be blocked by pr
55. ormation provides the current port status _ Speed Duplex Rx Byte Tx Byte PoE I 0 NoSupply ful 31913127 640601 NoSupply H H NOSU Zei 28784 1596 Nosupply P 2 e Figure 5 11 Port Status Interface 5 3 2 Port Configuration Users can assign or insert a value label for each port under each Port Name box enable or disable each port function state the speed duplex of each port and enable or disable the flow control of the port Port Configuration PORT Port name Status Speed Duplex SE Enable y Enable y REECH Enable y Enable y Enable Y Figure 5 12 Port Configuration Interface 18 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Pont No It shows each port status Up for link active and down for link inactive Status Enable or disable a port User can set the bandwidth of each port as auto negotiation 100 full 100 Speed Duplex half 10 full 10 half mode Support symmetric and asymmetric mode to avoid packet loss when Flow Control congestion occurred Apply Click Apply button to save changes Value Description User can create or insert a value or label for each port s identification Click to undo any changes made locally and revert to previously saved values Figure 5 13 Port Configuration Description 5 4 PoE Power over Ethernet LMP 0600 series is one of Antaira s industrial PoE managed switches tha
56. p server enable no snmp server community ro rw no snmp server v3 level admin user no snmp server v3 auth admin user no snmp server v3 encryption admin user show snmp server enable show snmp server community ro rw show snmp server v3 level admin user show snmp server v3 auth admin user show snmp server v3 encryption admin user snmp trap enable snmp trap host DESTINATION IP snmp trap version 1 2c 3 traps inform snmp trap community trap community name snmp trap inform retry retry time snmp trap inform timeout retry interval snmp trap v3 user user ID snmp trap v3 level auth noauth priv snmp trap v3 engine ID enginelD snmp trap v3 auth md5 sha PASSWORD snmp trap v3 encryption des aes PASSWORD no snmp trap enable no snmp trap host no snmp trap version no snmp trap community no snmp trap inform retry no snmp trap inform timeout no snmp trap v3 user no snmp trap v3 level no snmp trap v3 engine ID no snmp trap v3 auth no snmp trap v3 encryption show snmp trap enable PWD configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure
57. pecification standard and it is possible to create a VLAN across devices from different switch venders IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frames Tag contains a VLAN Identifier VID that indicates the VLAN numbers Ports in a port based VLAN are referred to as untagged ports and the frames received on the ports as untagged frames The names derive from the fact that the frames received on a port do not contain any information that indicates VLAN membership and that VLAN membership is determined solely by a port s PVID All of Antaira s industrial managed switches have a default VLAN setting set to none for each port so the users can login to the VLAN setting interface to create a VLAN Group name and choose Tag or Untag for each port 802 10 VLAN 802 10 VLAN Figure 5 35 802 1Q VLAN Settings Interface 36 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 7 2 802 1Q VLAN Settings 802 10 VLAN Port 802 10 VLAN Port Filter Figure 5 36 802 1Q VLAN Settings Interface PVID User can assign a Port VLAN ID for each port User can choose any port be Tagged or Untagged Tagged VLAN set the tagged PVIDs to carry different VLAN frames to other switch Untagged VLAN set the port PVID for untagged devices that connect to the port The range of PVID is 1 to 4094 Figure 5 37 802 1Q VLAN Settings Terms amp Va
58. priority value is supported Oto7COS value map to 4 priority queues Highest SecHigh SecLow and Lowest 40 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Users can set each port s priority queue from O to 7 by Default Cost clicking from dropdown box of which 0 is the Highest and 7 is the Lowest Apply Click Apply button to save changes Figure 5 42 QoS Classification Terms amp Value Description 5 9 2 CoS Mapping CoS Mapping Priority kl E a ad a a a a Figure 5 43 CoS Mapping Interface Users can assign each port a CoS value from 0 to 7 According to the IEEE 802 1p user can define each CoS Cos Value 0 7 value in 4 priority queues from Low to Normal Medium and High Click Apply button to save changes Figure 5 44 QoS Mapping Terms amp Value Description 41 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 9 3 ToS Mapping ToS is an acronym for Type of Service It is implemented as the IPv4 ToS priority control It is fully decoded to determine the priority from the 6 bit ToS field in the IP header The most significant 6 bits of the ToS field are fully decoded into 64 possibilities and the singular code that results is compared against the corresponding bit in the IPv4 ToS priority control bit 0 63 3 HigF Higr T 3 HigF Users can assign each ToS value with 4 priority queues fo
59. queries by the forwarding process as to whether a frame received by a given port with a given destination MAC address is to be forwarded through a given potential transmission port 5 13 1 MAC Address Table MAC Address Table MAC Address Table 00 00 21 ff ff ff 00 20 4a ea 70 d3 00 30 ab 26 cb 04 00 50 7f 47 22 8a 01 00 5e 00 01 3c 01 00 5e 7f ff fa 10 bf 48 5a b4 0d lc af f7 7c 5b f6 30 85 a9 a7 9d 63 30 85 a9 a8 05 bb 44 6d 57 47 27 04 48 5b 39 d1 1f 06 54 53 ed af 5c bd Foreb 0d 08 01 5e ed 3f 49 07 44102 ec 43 16 6f 30 fd f rce d6 c8 01 9f learning learning learning learning static static learning learning learning learning learning learning learning learning learning learning Figure 5 60 MAC Address Table Interface 5 13 2 MAC Table Configuration Users can check the checked box of each port and insert the port s VID and MAC address of the device that is connected to that port then click the Add button to continue adding other ports information Click the Apply button to save all the settings MAC Table Configuration MAC Table Configuration Figure 5 61 MAC Table Setting Interface 50 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 14 Maintenance Under the maintenance section users can execute updated firmware upgrade system reboot and reset the system to factory default 5 14 1 Upgrade Antaira is continuously
60. ress es any system warning message Click Apply button to save changes Figure 5 57 SMTP Setting Terms amp Value Description 48 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 12 4 Event Selection Users can select any event type through the Event Selection interface such as System Cold Start any ports Link Up Link Down Link Up Link Down and send the system warning massage to either SYSLOG or SMTP or both at the same time After the event selection users can click the Apply button to save changes Event Selection EVENT SELECTION Event Figure 5 58 Event Selection Setting Interface 5 12 5 Fault Alarm When any selected fault event has occurred the fault LED of the switch s front panel will light up and the electric relay will signal at the same time Users can check the checkbox of any Fault Alarm type such as power failure port link down or broken through the Fault Alarm setting interface to trigger this function Fault Alarm FAULT ALARIM Powerl Failure Power2 Failure Porti Link Down Broken Port Link Down Broken Port3 Link Down Broken Port4 Link Dovwn Broken Port5 Link Down Broken Port Link Down Broken Figure 5 59 Event Selection Setting Interface 49 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 13 MAC Table The MAC address table is the filtering database that supports
61. rm O Low to 1 Normal 2 Medium and 3 High Click Apply button to save changes Figure 5 46 ToS Mapping Terms amp Value Description 42 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 9 10 Port Mirroring Enable or disable mirroring feature When enabled a copy of matched frames will be mirrored to the destination port specified in the port mirroring interface Port Mirroring PORT MIRRORING Port Mirror Mode Go To Interface Monitor Direction Source Port Porti Port2 Port3 Port4 Ports Port6 Figure 5 47 Port Mirroring Configuration Interface Port Mirror Mode Enable Port Mirroring function by check the box Users can use the dropdown box to choose the Go To Interface NN l destination port as Port to mirror on feature l l Users can select the monitor direction from the dropdown Monitor Direction box by Tx Rx or Tx Rx Users can decide any particular port as the source port s will require port mirroring Source Port Cl e Click Apply button to save changes Figure 5 48 Port Mirroring Terms amp Value Description 43 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 11 SNMP Simple Network Management Protocol SNMP is the protocol developed to manage nodes servers workstations routers switches and hubs etc on an IP network SNMP enables network administrators to manage
62. roud to introduce and implement Ethernet Ring Protection Switching ERPS protocol as a standard ring solution for network redundancy with all new industrial managed Ethernet switches In order to provide users with the flexibility and compatibility when there are any existing switches that contains the standard ERPS protocol Ethernet Ring Protection Switching ERPS defined in ITU T G8032 implements a protection switching mechanism for Ethernet traffic in a ring topology By performing the ERPS function potential loops in a network can be avoided by blocking traffic to flow to the ring protection link RPL to protect the entire Ethernet ring In a network with ring topology that runs ERPS only one switch is assigned as an owner that is responsible for blocking traffic in RPL so as to avoid loops The switch adjacent to the RPL owner is called the RPL neighbor node that is responsible for blocking its end of the RPL under normal condition Other participating switches adjacent to the RPL owner or neighbor in a ring are members or RPL next neighbor nodes to this topology and normally forward receive traffic ERPS like STP provides a loop free network by using polling packets to detect faults When a fault occurs ERPS heals itself by sending traffic over a protected reverse path less than 50ms and recover quickly to forward traffic Because of this fault detection mechanism the network broadcast storm problem could be avoided as well
63. s IP30 rated and DIN rail mountable that provides a standard operating temperature range 10 C to 70 C and an extended operating temperature range 40 C to 75 C It also designed with high EFT and ESD protection to prevent any unregulated voltage for industrial networking applications in process control automation intelligent transportation systems ITS power utility water wastewater treatment plants any outdoor or harsh environment 1 2 Product Software Features py Network Redundancy e STP RSTP MSTP ITU T G 8032 Ethernet Ring Protection Switch ERPS for network redundancy E Network Management e Web UI based management SNMP v1 v2 serial console e Qos traffic classification QoS Cos bandwidth control for Ingress and Egress broadcast storm control Diffserv e IEEE802 1q VLAN port based VLAN support e IGMP snooping v1 v2 IGMP filtering throttling IGMP query up to 256 group e Supports RMON MIB II port mirroring event syslog DNS NTP SNTP SSH SSL TFTP R Advanced PoE Ports Management Auto Ping Check e Auto powered device PD detection Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Auto reset cycle power to unresponsive PD H POE ports weekly power scheduling B Port Configuration e Status statistics mirroring rate limiting event syslog B Event Handling e Event notification by email cold warm start power failure authentication SNMP trap and fault alarm relay output So
64. t has four built in IEEE802 3at complaint ports and each PoE port can support PoE output power up to a maximum of 30W per port It is also backward compatible with IEEE 802 af to support any standard PoE powered devices PD 5 4 1 PoE Configuration Status Mode Consumption No PD Detected Enable T 0 00 Figure 5 14 PoE Port Configuration Interface 19 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 Value Description PoE Port Number Any PoE port will automatically detect any powered device that is connected and will display the situation Users can use the dropdown box to enable or disable any PoE port function Set the PoE power output limit value The maximum value must be less than 30 0W Click Apply button to save changes Figure 5 15 PoE Port Configuration Description 5 4 2 Ping Alarm The PoE ping alarm function is using the ping command to turn on or off any PoE power output port Users can insert any particular powered device s IP address and set the interval time for a power recycle timing the particular PoE port Power over Ethernet PoE KEEPALIVE PD IP Address Cycle Time s m m oa mo A UN Gm GEB UN UD GS UND UD gp CDD CHO SW SG Sg GB Wm GUB Wm GG R 9 R WW Wm Wm Sr SG Wm SG Wm Sp Wm Gm CD CHO SES SS m sm m oam BOW eee Figure 5 16 PoE Ping Alarm Interface 20 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5
65. tial treatments Traffic Prioritization includes three modes port base 802 1p COS and TOS DSCP By traffic prioritization function users can classify the traffic into four classes for differential network application All of Antaira s industrial managed switches support four priority queues 39 Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 5 9 1 QoS Classification Qos Classification Choas Classification Queue Scheduling Weighted bl Trust Mode Port 1 n d d Port 2 Port 3 Port 4 Port 5 Port 6 S gg u pa a 4 3 A la Default Cos Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Figure 5 41 QoS Classification Interface Users can set it as Weighted or Strict Weighted mode An 8 4 2 1 weighting is applied to each round robin priority queue Queue Scheduling l Strict mode It gives egress queues with higher priority to be transmitted first before lower priority queues are serviced Users can select the trust mode with either DSCP or Cos When select DSCP only trusted DSCP Differentiated Services Code Point values are mapped to a specific QoS class and drop precedence level DPL Frames with untrusted DSCP values are treated as non IP Trust mode frames Cos Class Of Service is well known as 802 1p It describes that the output priority of a packet is determined by user priority field in 802 1Q VLAN tag The
66. user manual Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMP 0600 series 6 port industrial PoE managed Ethernet switch with 4 10 100Tx 30W Port RJ45 ports and 2 10 100Tx RJ45 ports W x D x H is 46mm x 99mm x 142mm 42 O 5000055000050000D09000 9006560000600 0006000050050 00006500000060000 900000000000 900090 005900090009000900 a Oo po Oo Dao po pO Oo DO oO Do a eoo oe oo Oe oo oe o a oo po o op Oo o po o op Oo o 9 o 2 o 9 2 23 9 o 3 23 9 EI 9 2 Figure2 1 LMP 0600 Series Physical Dimensions Antaira Industrial Ethernet Switches LMP 0600 Series User Manual V1 0 2 2 Front Panel The front panel of the LMP 0600 series industrial PoE managed Ethernet switch is shown below in Figure 2 2 6 Pin Removal Terminal Block Power Input LED for PWR1 LED for PWR2 LED for FAULT LED for OWNER Ring Master LED for RING Ring Status RESET Button 10 100Tx Ethernet Port 10 100 Tx Ethernet Port RJ45 for Serial Console RS232 USB for Configuration backup LED for Ethernet Port Status 10 100 Tx Ethernet Fort LED for PoE Power Status Figure2 2 The Front Panel of LMP 0600 Series 2 3 Top View Figure 2 3 below shows the top panel of the LMP 0600 series switch that is equipped with one 6 pin removal terminal block connector for dual

Download Pdf Manuals