UVA, UVC Light Meter with Temperature

image

Contents

1. 0 2 1 0 C 0 1F 58 0 to 2012 0 F 58 1 to 148 0 F 0 2 1 0 F 0 2 1 8 F Note Above specifications tested with an RF strenghth less than 3V M and a frequency less than 30MHz Copyright 2014 2015 FLIR Systems Inc Alle Rechte vorbehalten einschlie lich des Rechts der vollst ndigen oder teilweisen Vervielf ltigung in jeder Form ISO 9001 Certified www extech com SDL470 en GB_v1 3 1 15
2. t CF From the t CF parameter screen use the arrow buttons to select the desired unit of measure Press ENTER to confirm setting and to move to the next parameter If desired press and hold the SET button for 2 seconds to exit to the normal operation mode or wait 7 seconds for the meter to automatically exit Set the Thermocouple Type K or J tYPE From the tYPE parameter screen use the arrow buttons to select the desired sensor type Press ENTER to confirm setting and to move to the next parameter If desired press and hold the SET button for 2 seconds to exit to the normal operation mode or wait 7 seconds for the meter to automatically exit System Reset If the meter s keys become inoperable or if the display freezes the Reset button can be used to reset the instrument Use a paper clip or similar item to momentarily press the reset button located on the lower right side of the instrument under the snap off compartment cover After pressing the Reset button switch the instrument ON by pressing and holding the POWER key for at least 2 seconds If using the power adaptor unplug the adaptor and then plug it back in again to power the meter 8 SDL470 en GB_v1 3 1 15 Datalogging and PC Interface Types of Data Recording Manual Datalogging Manually log up to 99 readings onto an SD card via push button press Automatic Datalogging Automatically log data onto an SD memory card where the number o
3. batteries located in the rear battery compartment When the adaptor is used the meter is permanently powered on and the power button will be disabled 11 SDL470 en GB_v1 3 1 15 Battery Replacement When the battery icon appears on the LCD the batteries must be replaced Several hours of test time are possible from when the battery symbol first appears but when critical data is at stake it s always best to start with a fresh set of batteries Remove the two Philips screws above the tilt stand on the rear of the meter Carefully open the battery compartment to access the batteries Remove the existing batteries and replace with six 6 fresh 1 5V AA batteries observing proper polarity 4 Close the compartment and secure with the two screws before attempting to use the meter 5 Note that the time and date must be reset when the batteries are replaced see the SETUP Mode section of this user guide Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever mm batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment Battery Safety Reminders o Please dispose of batteries responsib
4. scale Datalogging 2 With the meter switched OFF remove the SD Card 3 Plug the SD Card directly into a PC SD card reader If the PC does not have an SD card slot use an SD card adaptor available at most outlets where computer accessories are sold 4 Power on the PC and run a spreadsheet software program Open the saved documents in the spreadsheet software program see example spreadsheet data screen below Spreadsheet data example eal B C bu Paal E F i Place Date Time Value Unit 2 i 1 2009 12 11 09 55 5 i JA mWiem 3 2 2009 12 11 4 UVA mWem2 4 j 3 2009 12 11 UVA mWyem2 Si 4 2009 12 11 09 5 UVA mWrem 6 S 2009 12 11 09 56 UYA mWicm2 7 6 2009 12 11 09 9 UVA mWiem2 8 7 2009 12 11 09 UVA mWicm2 9 8 2009 12 11 09 5 3 UYA mW cm2 10 9 2009 12 11 09 56 3 UYA mWiem2Z FLY 10 2009 12 11 09 UVA mWiem 12 11 2009 12 11 09 UVA mWiem 13 12 2009 12 11 09 73 UVA mWiem2 14 13 2009 12 11 99 UVA mWiem 15 14 2009 12 11 09 UYA mW cem2 14 15 2009 12 11 09 UVA mWifem2 17 16 2009 12 11 09 T UVA mWiem2 18 17 2009 12 11 09 UVA mW 19 1 2 f ag UVA mv 20 19 09 UVA mW 21 2 a9 UVA mWVicm2 RS 232 USB PC Interface For streaming of data to a PC via the RS232 Output jack 3 5mm the optional 407001 USB kit RS232 to USB cable and driver CD along with the 407001 software available free at www extech com SDL470 are required AC Power Adaptor This meter is normally powered by six 6 1 5V AA
5. EXTECH USER GUIDE INSTRUMENTS UVA UVC Light Meter with Temperature Model SDL470 UVA UVE Light Meter SDL470 O O O Introduction Thank you for selecting the Extech Instruments Model SDL470 Ultraviolet Light Meter The SDL470 measures UVA and UVC light plus temperature This device is shipped fully tested and calibrated and with proper use will provide years of reliable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates and Customer Support Features e UVA and UVC light measurement in one meter e Long wave 365 nm ultra violet irradiance measurements UVA e Professional UVA meter used to measure the UVA Radiation from UVA light black light e Short wave 254 nm ultra violet irradiance measurements UVC e Professional UVC light meter measures UVC irradiation from UVC light source e Two ranges 2 mW cm42 and 20 mW cm42 e Meter includes two probes UVA probe and UVC probe e UV Sensor with cosine correction filter e UV Zero feature e Applications include Monitoring blue light radiation from welding equipment UV sterilization graphic arts photochemical matching UV EPROM erasure Photo resist exposure ink curing adhesives and coatings e Microprocessor circuit provides high reliability and durability e Separate UV light probe allows the user to measure UV light with optimum positioning e Type K and Type J thermocouple ther
6. X and MIN readings Press the MAX MIN button again to view the current MAX readings MAX icon appears The readings on the display are now the highest readings encountered since the REC icon was switched on when the MAX MIN button was first pressed Press the MAX MIN button again to view the current MIN readings MIN icon appears The readings on the display are now the lowest readings encountered since the REC icon was switched on when the MAX MIN button was first pressed To exit the MAX MIN mode press and hold the MAX MIN button for at least 2 seconds The meter will beep the REC MAX MIN icons will switch off the MAX MIN memory will clear and the meter will return to the normal operating mode 5 SDL470 en GB_v1 3 1 15 Setup Mode Time Date and Datalogger Sample Rate settings at a glance To view the current configuration of the meter with regard to time date and sample rate press the SET button momentarily The meter will now display the configuration in quick succession If the information is missed on the first try simply press the SET button again until all of the information is noted Accessing the Setup mode 1 2 Press and hold the SET button for at least 2 seconds to access the Setup menu In the Setup Mode press the SET button momentarily to step through the available parameters The parameter type is shown on the bottom of the LCD and the current selection for that type is shown above it When a parameter i
7. d is defective the meter will display a CARD error In this case switch the meter OFF and try again with a valid SD card Pause the datalogger by pressing the LOG button momentarily The REC icon will switch OFF To resume logging press the LOG button again momentarily To terminate the Datalogging session press and hold the LOG button for at least 2 seconds When an SD card is used for the first time a folder is created on the card and named UVA01 Up to 99 spreadsheet documents each with 30 000 readings can be stored in this folder When Datalogging begins a new spreadsheet document named UVA01001 xls is created on the SD card in the UVAO1 folder The data recorded will be placed in the UVA01001 xIs document until 30 000 readings are reached If the measurement session exceeds 30 000 readings a new document will be created UVA01002 xIs where another 30 000 readings can be stored This method continues for up to 99 documents after which another folder is created UVAO2 where another 99 spreadsheet documents can be stored This process continues in this same fashion with folders UVAO3 through UVA10 last allowable folder 10 SDL470 en GB_v1 3 1 15 SD Data Card to PC Data Transfer 1 Complete a Datalogging session as detailed above in the previous sections Hint For the first few tests simply record a small amount of test data This is to ensure that the Datalogging process is well understood before committing to critical large
8. e If this is the first time the meter is powered ON or if the batteries have been replaced the meter may display the SET DATE message to remind user to set the date and time see the SETUP MODE section for setting the time and date e Scroll through the three measurement options UVA LIGHT UVC LIGHT or TYPE K J THERMOMETER by pressing and holding the Function button The display icons are A for UVA Light C for UVC Light and tP for Type K J thermometer UVA Light Meter e Insert the UVA Probe Plug into the Probe Input Socket e Switch the meter ON by pressing and holding the Power button for at least 2 seconds e Select the UVA Light Meter option as described above in the Function Measurement Selection section e The display will show the mW cm 2 unit of measure e The meter is now ready to make UVA light measurements e Holding the Sensor Handle face the UVA Sensor toward the source of UVA light e The display will show the measurement reading UVC Light Meter e Insert the UVC Probe Plug into the Probe Input Socket e Switch the meter ON by pressing and holding the Power button for at least 2 seconds e Select the UVC Light Meter option as described above in the Function Measurement Selection section e The display will show the mW cm 2 unit of measure e The meter is now ready to make UVC light measurements e Holding the Sensor Body face the UVC Sensor toward the source of UVC light e The display will show the
9. e next parameter If desired press and hold the SET button for 2 seconds to exit to the normal operation mode or wait 7 seconds for the meter to automatically exit Numerical Format comma or decimal dEC European and USA numerical formats differ The meter defaults to USA mode where a decimal point is used to separate units from tenths i e 20 00 The European format uses a comma i e 20 00 to separate units from tenths To change this setting 1 2 3 From the dEC parameter screen use the arrow buttons to select USA or Euro European Press ENTER to confirm setting and to move to the next parameter If desired press and hold the SET button for 2 seconds to exit to the normal operation mode or wait 7 seconds for the meter to automatically exit 7 SDL470 en GB_v1 3 1 15 SD Card FORMATTING Sd F 1 From the Sd F parameter screen use the arrow buttons to select YES to format the card select NO to abort Note that all data on the card will be lost if formatting is attempted If NO was selected press ENTER to confirm and to move to the next parameter If YES was selected press ENTER and then press ENTER again when ent is shown The meter steps to the next parameter automatically after the SD card is formatted If desired press and hold the SET button for 2 seconds to exit to the normal operation mode or wait 7 seconds for the meter to automatically exit Set the Temperature Units of Measure C or F
10. f data points is virtually limited only by the card size Readings are logged at a rate specified by the user SD Card Information Insert an SD card from 1G size up to 16G however 4GB sized cards or smaller are recommended into the SD card slot at the bottom of the meter The card must be inserted with the front of the card label side facing toward the rear of the meter If the SD card is being used for the first time it is recommended that the card be formatted and the logger s clock set to allow for accurate date time stamping during Datalogging sessions Refer to the Setup Mode section for SD card formatting and time date setting instructions European and USA numerical formats differ The data on the SD card can be formatted for either format The meter defaults to USA mode where a decimal point is used to separate units from tenths i e 20 00 The European format uses a comma i e 20 00 To change this setting refer to the Setup Mode section Manual Datalogging In the manual mode the user can manually log one reading at a time onto the SD card up to 99 readings 1 Set the sampling rate to 0 seconds as described in the Setup Mode section 2 Press and hold the LOGGER button for at least 2 seconds the LOGGER icon will appear 3 Ifan SD card is not installed in the meter the display will show an error message CARD 4 In an SD card is installed the lower portion of the display will show P n n memory positio
11. ly observe local state and national regulations o Never dispose of batteries in a fire batteries may explode or leak o Never mix battery types install new batteries of the same type 12 SDL470 en GB_v1 3 1 15 Specifications General Specifications Display Backlit LCD size 52 mm x 38 mm 2 0 x 1 5 Measurements UV light UVA and UVC Type K or J thermocouple temperature UVA UVC selection Front push button UV Sensor spectrum UVA 390 280nm UVC 280 240nm UV sensor Exclusive photo sensor with cosine correction filter UV light zero adjust Push button Data storage recall Records Max and Min readings with recall Datalogger Auto 1 second to 3600 second sample rate Manual Button press sample rate set to 0 Memory SD card 1G to 16GB SD Card for best results use a 4GB or smaller card Temperature compensation Auto compensation for the Type K J thermocouple thermometer Display sampling rate 1 second approx Data output RS 232 USB PC interface Operating Temperature 0 C to 50 C 32 F to 122 F Operating Humidity Less than 85 RH Power Supply Alkiline 1 5V AA batteries x 6 or 9V AC adaptor UA100 240 Power Consumption Normal operation without SD storing and with display backlight OFF 6 5mA DC approx With SD card storing but display backlight OFF 30mA DC approx With the LCD backligh
12. measurement reading LCD Backlight e Press and hold the HOLD Backlight button for 2 seconds to switch the LCD backlight ON OFF ZERO Adjustment e Cover the light sensor with the protective cover e Ifthe meter display does not read zero press and hold both the up and down arrow buttons simultaneously for at least 3 seconds e The display will automatically zero e Remove the sensor cover to begin taking measurements 4 SDL470 en GB_v1 3 1 15 Type K J Thermometer Measurements Probe is optional Plug a thermocouple not supplied into the temperature probe jack at the top of the meter Switch the meter ON by pressing and holding the Power button for at least 2 seconds Select the Thermocouple function as described in the Function Measurement Selection section The meter display will show the temperature measurement along with the K or J thermocouple indicator The meter defaults to Type K thermocouple refer to the Setup Mode section for instructions on how to change the thermocouple type Data Hold Press the HOLD button momentarily to freeze the displayed reading The HOLD display icon will appear Press the HOLD button again to release the display The HOLD display icon will switch OFF MAX MIN Reading Store Recall For a given measurement session this meter can record the highest MAX and the lowest MIN readings Press the MAX MIN button momentarily REC icon appears The meter is now recording the MA
13. mometer probe not included e Real time SD memory card Datalogger built in calendar clock real time data recording with selectable sampling time rate from 1 second to 3600 seconds e Manual Datalogging set the sampling rate to 0 e Simple innovative operation PC not required to setup Simply use the SD card to transfer data from meter to PC e SD card capacity 1 GB to 16 GB e LCD with green backlight is easy to read e Meter can be set to default on auto power off or manual power off e Includes Data hold Record MA and MIN readings e Powered by AA 1 5 V x 6 batteries or DC 9V adaptor e RS232 USB PC computer interface 2 SDL470 en GB_v1 3 1 15 Meter Description 1 LCD display 2 HOLD and LCD Backlight button 3 Power button 4 Uparrow A and UNITS button 5 Down arrow W and FUNCTION button 6 MAX MIN button 7 Time Date Check and SET button 8 ENTER and LOG button 9 Side compartment detailed below 10 UVA Probe and UVC Probe input plug 11 Type K J thermocouple socket 12 SD Card Slot 2 13 UVC sensor 14 UVA probe handle 15 UVA sensor protective cover not shown 13 Note Battery compartment tilt stand and tripod mount are located on rear of meter 1 DC 9V power adaptor jack 2 Reset button 3 RS 232 output port 3 SDL470 en GB_v1 3 1 15 Operation Function Measurement Selection e Power the meter ON or OFF by pressing and holding the Power button for at least 2 seconds
14. n number 1 99 5 Usethe A and Y buttons to select one of the 99 data memory positions in which to record 6 Momentarily press the LOG button to store the reading the SCAN CARD display icon will show briefly as the reading is stored in the selected location Repeat steps 5 and 6 for up to 99 readings 7 To exit the manual Datalogging mode press and hold the LOG button for at least 2 seconds The Pn and LOGGER icons will switch off 9 SDL470 en GB_v1 3 1 15 Automatic Datalogging In automatic Datalogging mode the meter stores a reading at a user specified sampling rate onto an SD memory card The meter defaults to a sampling rate of one second To change the sampling rate refer to the Setup Mode section the sampling rate cannot be O for automatic Datalogging 1 10 Select the sampling rate in the Setup Mode refer to Setup Mode section to a value other than zero Ensure that a formatted SD card is properly inserted in the meter s SD card slot When inserted the SD card label should be facing the rear of the meter for proper orientation Press and hold the LOG button for two seconds The REC display icon will flash once per second and the LOGGER display icon will flash at the selected sampling rate Note that if the battery is low the BAT icon will flash and Datalogging will not start Replace the batteries at this point refer to the Battery Replacement section If an SD card is not inserted or if the car
15. s displayed that is to be changed use the up down arrow buttons to change the setting Press the ENTER button to confirm a change Press and hold the SET button for at least 2 seconds to exit the Setup mode Note that the meter automatically switches out of the Setup mode if no key is pressed within 7 seconds The available Setup parameters are listed below Additional detailed information is provided below this list dAtE Set the clock Year Month Date Hours Minutes Seconds SP t Set the datalogger sampling rate 1 2 5 10 30 60 120 300 600 1800 3600 seconds PoFF Auto power off management Enable or disable the auto power off function bEEP Set the beeper sound ON OFF dEC Set the numerical format USA decimal 20 00 or European comma 20 00 Sd F Format the SD memory card tCF Units of measure selection for temperature readings C or F tYPE Select the Thermocouple type K or J Setting the Date and Clock dAtE 1 2 3 4 Access the dAtE parameter as described in the Accessing Setup Mode section above Use the ENTER button to step through the YY MM DD HH MM SS selections Use the up down arrow keys to change a value press and hold to scroll quickly Continue through all of the date and time settings in this manner After the last ENTER press the meter will automatically advance to the next setup parameter If desired press and hold the SET button for 2 seconds to exit to the normal operation mode or wait 7 second
16. s for the meter to automatically exit The clock will keep accurate time even when the meter is switched off However if the battery expires the clock will have to be reset after fresh batteries are installed 6 SDL470 en GB_v1 3 1 15 Setting the Datalogger Sampling Time Rate SP t 1 From the SP t parameter the sampling rate can be set to 0 seconds for manual logging or 1 2 5 10 30 60 120 300 600 1800 3600 seconds for auto logging Use the up down arrow buttons to select the sampling rate press and hold for quick scroll Press the ENTER button to confirm the entry and automatically step to the next parameter Press and hold the SET button for 2 seconds to exit to the normal operation mode or wait 7 seconds for the meter to automatically exit Enabling Disabling the Auto Power OFF Feature PoFF 1 From the PoFF parameter screen use the arrow buttons to select ON enable or OFF disable With the Auto Power OFF feature enabled the meter will automatically switch OFF after 5 minutes of inactivity Press ENTER to confirm setting and to step to the next parameter If desired press and hold the SET button for 2 seconds to exit to the normal operation mode or wait 7 seconds for the meter to automatically exit Set the Beeper Sound ON or OFF bEEP 1 From the bEEP parameter window use the arrow buttons to select ON enable or OFF disable Press ENTER to confirm setting and to move to th
17. t ON the power consumption increases by 16mA DC approx Weight Meter 351g 11 3 oz UVA Probe 100g 3 2 oz UVC Probe 103g 3 3 oz Dimensions Meter 177 x 68 x 45mm 7 0 x 2 7 x 1 8 UVA Probe head 45 mm diameter x 32 mm 1 8 dia x 1 3 UVA Probe handle 125 x 24 mm diameter 5 0 x 0 9 dia UVC probe 38mm diameter x 25 mm 1 5 dia x 1 0 Accessories included Instruction manual UVA light sensor UVC light sensor hard shell carrying case batteries 9V AC adapter and user guide Optional Accessories Type K thermocouple probe USB cable 407001 USB and data acquisition software 407001 13 SDL470 en GB_v1 3 1 15 Electrical Specifications UV Light UVA UVC Ranges and Resolution Range 1 1 999 mW cm 2 max Range 2 19 99mW cm 2 max Accuracy 4 FS 2 digits FS Full Scale UVA Calibration executed under UVA light and compared with UVA light meter standard UVA 390 280nm UVC Calibration executed under UVC light and compared with standard UVC light meter standard UVC 280 240nm Type K J Thermocouple Thermometer Sensor type Resolution Range Accuracy Type K 0 1C 50 0 to 1300 0 C 50 1 to 100 0 C 0 2 0 5 C 0 2 1 0 C 0 1F 58 0 to 2372 0 F 58 1 to 148 0 F 0 2 1 0 F 0 2 1 8 F Type J 0 1C 50 0 to 1100 0 C 50 1 to 100 0 C 0 2 0 5 C

Download Pdf Manuals

image

Related Search

Related Contents

トラブルシュート一覧表 - OS Engines  Danby DWC040A2BDB User's Manual  安全上のご注意 「外国為替及び外国貿易法による規制」のご案内  Gardner Bender GVD-3504 Operating Instructions  Manuel d`utilisation Bloc électrique EBL 99 G  Kenroy Home 32424MOB Use and Care Manual  RÉFRIGÉRATEUR À PORTE-FENÊTRE  AT-216F _A1.cdr    LoudenLoudenLouden LoudenLoudenLouden  