1. s upper flow limit In the event of excessive flow detection the controller turns off the faulty station advances the program to the next station condemns the station from any future watering times and triggers audible if enabled and visual alarm indicators Automatic Detection of station s no flow condition When flow is expected and the controller measures a zero flow the controller turns off the faulty station advances the program to the next station condemns the station from any future watering times and triggers audible if enabled and visual alarm indicators Alarms that create a no watering condition will be bypassed until the alarms are cleared All non irrigation programs will continue to operate as scheduled Special Two wire diagnostics e The SINGLE station test function allows the user to test that a specific station has a programmed decoder and has a corresponding solenoid connected to it The solenoid current is automatically range checked for validity If valid the current is displayed at the controller if not valid the user is notified of an Open Circuit No Solenoid Connected or Over Current condition e The ALL PROGRAMMED test function tests all stations that currently appear in one or more user programs The test indicates the total number of programmed decoders that have a corresponding solenoid connected to it The solenoid current is automatically range checked for validity If valid the current is displayed
2. 1 5 Regional Settings e The date may be displayed in MM DD YY default or DD MM YY format e The time may be displayed in 12 or 24 hour clock format 1 6 Diagnostic and Fault Detection The Rain Master Eagle Plus controller supports extensive diagnostics and fault detection capability e The display reports the fault conditions The visual Alarm LED indicator illuminates and an audible chirp enabled disabled in setup is also generated until all faults are cleared e The controller automatically maintains a historical list of up to 220 alarms in chronological order e Automatic field wire fault detection enables the controller to sense a short in the field wire and instantly turn off that station The controller will automatically advance past the faulty station to the next programmed station 3 Online Only RAIN MASTER CENTRAL CONTROL Automatic detection of main line water breaks In the event of a main line break the controller shutdown all active irrigation de energizes a normally closed master valve or energizes a normally open master valve condemns any future start times triggers audible if enabled and visual alarm indicators Automatic detection of unscheduled water flow In the event of an unscheduled flow exceeds the user defined allowable flow the controller activates the normally open master valve condemns any future start times triggers audible if enabled and visual alarm indicators Automatic detection of station
3. of flow sensors 1 and 2 Configurable flow sensor pipe sizes for standard Rain Master flow sensors as well as the ability to configure non Rain Master flow sensors o Brass 1 0 1 25 1 5 2 0 2 5 inch sizes o PVC 1 5 2 0 3 0 4 0 inch sizes Configurable main line flow limit from 0 5000 GPM defines the maximum allowable flow during scheduled irrigation Configurable unscheduled flow limit from 0 999 GPM defines the maximum amount of flow that will be permitted during unscheduled irrigation periods Configurable station upper flow limits from 0 999 GPM Configurable flow check delay between 1 and 6 minutes 1 minute increments This delay permits stations to stabilize before limit checks are applied Automatic monitoring and display of measured station flow from 0 to 999 GPM Configurable station flow limits station flow limits can be configured based on auto learned nominal flow or can also be configured by entering limits manually o In LEARN mode a global percentage adjustment from 5 to 80 is used to automatically factor upper flow limits for all stations once the nominal values have been measured Intelligent upper limit processing for simultaneous station operation A water usage meter indicates total water used by the controller on a per month basis 12 month period The water usage totalizer function measures the total flow over a period of time The user may elect to reset the flow total at any time EVAPOTRANSPI RATION
4. that the sensor is active This feature allows non irrigation programs such as lighting controls to execute independent of these devices e A water usage reading indicates total water used by the controller on a per month basis Up to one years worth of data shall be maintained 2 Online Only RAIN MASTER CENTRAL CONTROL 1 4 Convenience Features The Rain Master Eagle Plus controller features an intuitive keyboard layout that provides ease of use RAIN MASTER EAGLE PLUS mam memanas A ea a irritrol e 20 character x 4 line LCD backlit display and 3 embedded LEDs Alarms Irrigation active and Water off Rain shutdown modes e An intuitive user interface utilizing an optical encoder with integrated entry function that allows the user to select options that are presented in the LCD display e During program execution the controller displays the active program number the flow in GPM and the station runtime countdown in hours minutes and seconds Flow sensor required to display flow e Multi Level 4 Digit Controller Security Access code can be used to prevent unauthorized use or modifications of the controller s programs e Restricted No Program or Setup changes without entering the access code but permits manual operation as well as Review and Water Off functions e No Access The user cannot perform any operation without entering the access code Review key to display current controller operations
5. ET FEATURES Ability to enable or disable ET adjustments on a per program basis The ability to use any one of four different ET sources as the basis for its ET calculations e Historical ET values e Manually entered ET value e Rain Master ET measurement device or equivalent e Downloaded ET data from the internet requires iCentral option The ability to input and store Historical ET values for a 12 month period Historical ET values can be obtained from www rainmaster com under the Literature Menu Historic ET Data The controller re calculates station runtimes prior to the start of irrigation utilizing the current day s ET value and up to 3 days prior if programs were not executed The ability to store an ET reference value This value is used during the adjusted station runtime ET calculations 5 Online Only RAIN MASTER CENTRAL CONTROL User may enter a manual ET value which overrides previously entered or accumulated ET data for 7 days At the end of the 7 day period the controller automatically reverts to utilizing Historic Device or Internet provided daily ET data Connectivity to an ET measuring device such as a Rain Master Weather Center The ability to display the last 14 days of daily ET values Ability to display the current ET percent adjustment for all ET enabled programs 4 0 KEY HARDWARE FEATURES The key features offered by the Rain Master Rain Master Eagle Plus controller hardware are 4 1 No b
6. RAIN MAIER CONTROL SYSTEMS Rain Master Eagle Plus Irrigation Controller Product Specification 1 0 BASIC RAIN MASTER EAGLE PLUS FEATURES The Rain Master Eagle Plus controller is available in two configurations Conventional and Two Wire Conventional Configuration e Modular station design that allows station counts from 8 stations up to 48 stations in increments of 8 stations e 8 independently controllable irrigation programs Two Wire Configuration e Serial Two Wire connection for up to 200 stations 100 decoders Maximum e 16 independently controllable irrigation programs e Cycle and Soak capability allows virtually unlimited start times allowing stations to start pause restart independently until their designated runtimes have been fulfilled 1 1 Standard Programming Capability The key features offered by the Rain Master Eagle Plus controller are e Programmable Runtimes for each station can be set from 1 minute to 23 hrs 59 minutes e Programmable delay time between station execution The programmed delay time can be from 0 to 19 minutes and 59 seconds e Programmable Total runtime Maximum Cycle runtime and Soak time on a per station basis e Programmable pump activation independent of the master valve on a per program basis e Programmable stacking or non stacking operation on a per program basis e Provides the ability to select either ODD or EVEN day watering on a per program basis e Water Days for each progr
7. am can be based on a 14 day cycle or a skip by day cycle The Water Days can be further restricted with the selection of ODD EVEN calendar days e Programmable water window setup option to ensure watering takes place only in a pre defined watering period e Selectable cycle and soak irrigation programming or conventional programming on a per program basis e Cycle and Soak capability allows virtually unlimited cycle times allowing stations to start pause and restart independently until their designated runtimes have been fulfilled e The Cycle and Soak feature intelligently displays the total runtime of the program e Displays the total runtime of a program The controller considers all soak delays water budget percentage daily ET percentage adjustments and inter station delays 1 Online Only RAIN MASTER CENTRAL CONTROL e Acopy function permitting an entire program to be copied to another program or an individual runtime to be copied to any station or any sequential block of stations within any program e Each program can be individually configured as an irrigation or non irrigation program 1 2 Manual Watering e Manual Water Offfeature provides a means to quickly turn off all irrigation programs without disturbing the stored programs Programs that are setup as non irrigation programs will continue to operate as scheduled e Manually activated system check test cycle to sequentially run each station for a user defined time peri
8. at the controller if not valid the user is notified of an Open Circuit No Solenoid Connected or Over Current condition e The FIND DECODERS test function allows the user to find all programmed decoders that are currently connected to the two wire bus The test indicates the total number of programmed decoders that have a corresponding solenoid connected to it The solenoid current is automatically range checked for validity If valid the current is displayed at the controller if not valid the user is notified of an Open Circuit No Solenoid Connected or Over Current condition e The ALL STATIONS test function tests stations 1 thru 200 master valves and pump The test indicates all the decoders that are currently connected to the two wire bus irrespective if their corresponding station appears in one or more of the controller s programs The test indicates the total number of decoders that are addressable and that have a corresponding solenoid connected to it The solenoid current is automatically range checked for validity If valid the current is displayed at the controller if not valid the user is notified of an Open Circuit No Solenoid Connected or Over Current condition 4 Online Only RAIN MASTER CENTRAL CONTROL 2 0 FLOW CONTROL AND MONITORING CAPABI LI I TES The Rain Master Eagle Plus controller has 3 0 Inputs for connectivity up to two flow sensors Ability to enable flow sensor 1 flow sensor 2 or a combination
9. attery is required Non volatile memory to retain the programs and controller setup information during power outages or seasonal shutdowns This information is maintained indefinitely A real time clock with non volatile backup to maintain the current date and time during power outages without the need of batteries e Clock maintains time for a minimum of 30 continuous days without power Advanced circuitry to automatically monitor internal voltages and reset on board microprocessor circuitry during electrical disturbances Automatic electronic fuse which resets intelligently based upon need no fuses or circuit breakers to reset or replace When a power outage occurs and power is restored the controller resumes its programmed real time irrigation schedule Output and Master Valve boards are equipped with quick connect terminals for ease of wiring Automatically detects board failures and generates an alarm Output Modules Master Valve Pump Station and Sensor I nputs Each station output module has e 8 stations e Quick connect terminals connectivity of up to 2 14 gauge wires e 2 quick connect common terminals capable of connecting up to 4 14 gauge commons per output module e Green LED diagnostic indicator when the station is powered on e Station outputs black vs commons green are differentiated via color coded terminal blocks Output modules can be added in the field The controller will re configure itself on power up to determin
10. e the maximum station count conventional configuration only Note Power must be disconnected during installation Each controller has a master valve sensor board with connectivity for each of the following e Flow sensor 1 e Flow sensor 2 e ET device e g Rain Master Weather Center e Sensor input capable of connecting to either a Rain Freeze Rain Freeze Moisture Wind or tipping bucket sensor device e g Rain Master Weather Center e Auxiliary 24 VAC terminal rated at 100 milliamps e Master Valve quick connect terminal with connectivity of up to 2 14 gauge wires e Common quick connect terminal with connectivity of up to 2 14 gauge wires 6 Online Only RAIN MASTER CENTRAL CONTROL e Pump Station quick connect terminal with connectivity of up to 2 14 gauge wires e Master Valve type can be configured to either a Normally Open Master Valve or a normally closed master valve e Master Valve control is assigned on a per program basis e Pump Station control is assigned on a per program basis 5 0 AVAILABLE RAIN MASTER EAGLE PLUS OPTIONS The Rain Master Eagle Plus controller has e Controller can be purchased as either a 200 station two wire or conventional up to 48 station Two Wire and Conventional configurations are mutually exclusive e Ability to connect to a Rain Master iCentral communication card iCard to provide connectivity to the iCentral Internet based central control software e Ability to interface to a Ra
11. in Master Weather Station for local ET data e Ability to connect to a Rain Master Flow sensor or other flow sensor device e Built in remote control capability and compatibility with Rain Mastere Pro Max remote control system e Connectivity for any one of the following dry contact sensors rain freeze rain freeze moisture or wind sensor devices The enabling of this device can be performed on a per program basis This feature allows non irrigation programs to execute independent of this device e Availability in a variety of enclosure options standard painted cold rolled steel wall mount stainless steel wall mount stainless steel security pedestals See dimensions below 6 0 MECHANICAL SPECI FI CATIONS e Standard size enclosure 18 gauge jet coat cold rolled steel enclosure with power coat paint or stainless steel models suitable for either indoor or outdoor environments e Wall Mount 11 W x 16 H x 5 625 D 27 9cm W x 40 6cm H x 14 29cm D e Pedestal Mount e PSB Heavy Duty 14 gauge stainless steel Strongbox enclosure 16 5 W x 38 H x 17 25 D 41 9cm W x 96 5cm H x 43 8cm D e SPED Heavy Duty 14 gauge stainless steel security enclosure SPED 16 W x 34 H x 16 D 40 6cm W x 86 4cm H x 40 6cm D e Temperature Range Operating 14 F to 140 F 10 C to 60 C Storage 22 F to 149 F 30 C to 65 C 7 0 ELECTRICAL SPECI FI CATIONS Internal Transformer Class 2 UL Listed CSA Certified o
12. od from 1 to 59 minutes e Manually activated program to execute a program independently of its programmed start time and water days e Manually activate up to 6 stations simultaneously for a user defined time period from 1 minute to 23 hours 59 minutes 1 3 Water Conservation Features Automatic Watering The Rain Master Eagle Plus controller features the following water conservation features e Evapotranspiration ET based scheduling selectable on a per program basis e Percentage adjustment on a per program basis to allow an increase or decrease of all station runtimes within that program The percentage allows adjustment from 0 to 300 in 1 increments this percent adjustment is applied to the run time e Re calculated station run times are executed to the nearest second e Programmable rain shut off in order to delay the start of irrigation after a rainstorm The controller does not water during the programmed delay period from 1 to 9 days After the delay period has expired the controller returns to the automatic mode of operation e Automatic minimization of the water window by intelligently scheduling station starts when other stations are satisfying their Soak Times e Automatic monitoring and display of measured station flow e Ability to intelligently monitor any dry contact sensor such as rain freeze rain freeze moisture and wind on a per program basis When the sensor is active irrigation stops and the display indicates
13. r equivalent e Input 120 VAC 10 50 60 Hz e Output 24 VAC 10 50 60 Hz 50 VA e Total Maximum Load 1 5A 24 VAC Output Surge Protection excluding 2 wire decoder models 6KV common 1KV normal e Conventional Configuration e Maximum Load Per Station 0 54 24 VAC 77 25 C e Maximum Load Per Master Valve 0 5A 24 VAC 77 F 25 C e Maximum Load Per Pump Output 0 54 24 VAC 77 F 25 C 7 Online Only RAIN MASTER CENTRAL CONTROL e Two Wire Configuration e Drive current to a decoder is 100 to 250 milliamps depending on the solenoid e Supports up to 100 decoders on the two wire path 8 0 DOCUMENTATION RAIN MASTER EAGLE Plus User s Manual RAIN MASTER EAGLE Plus Quick Reference Guide English and Spanish RAIN MASTER EAGLE Plus Installation Guide RAIN MASTER EAGLE Plus Product Brochure RAIN MASTER EAGLE Plus Product Specification 9 0 CERTIFI CATION AND WARRANTY e UL C UL and FCC approved e Limited 5 year warranty Irritrol 2013 Online Only
Download Pdf Manuals
Related Search
Related Contents
Samsung PS-42P4A1 Bruksanvisning Manual de utilização da aplicação web “Gestão de Handler 120/150 y antorcha Piecemaker 14A Betriebs- und Installationsanleitung Philips AZ7182 User's Manual qui Multi-Media Solutions Digital Signage Platform NDiS 127 User Manual Installation Instructions Samsung AR09JSPFBWKNEU Užívateľská príručka 4 - Saint-Max Copyright © All rights reserved.