1. These inputs can be used for switches float switches water sensors flow sensors etc Switch inputs connected to probe modules will be identified as Swx3_2 Swx5_3 etc The first number in the switch name corresponds to the AquaBus address assigned to the probe module The second number corresponds to the switch input number 1 6 1 WARNING Do not apply voltage to the switch inputs or damage to the AquaController Apex may occur The pin out of the connector is shown in Figure 1 Switch Input Connector Connect switches to the AquaController Apex by connecting one wire from the mechanical switch to the ground pin pin 8 and the other wire from the switch to one of the six digital inputs pin 1 6 Connections can be easily made using a Neptune I O Breakout box available at your local Neptune Retailer The breakout box features spring loaded connectors to make connections easy without tools or soldering AquaController Apex Probe Module 1 Setup Guide Page 6 POS TEE The Apex and accessory inputs are TTL level 5V inputs with internal pull up resistors With nothing connected the switch inputs will indicate OPEN Logic 1 5V When connected to Ground Pin 8 the switch will indicate CLOSED Logic O OV Table 2 Switch Input Connector Pin out Switch Inputs are programmed using the If Switch command For example if you wanted to turn a pump on when a float switch closes you would add this command to the pump out
2. 0 Table 1 Calibration Solutions NOTE For best results use pH calibration solutions in packets as the solution in bottles tend to shift pH after they have been opened To calibrate a pH probe 1 Acquire the proper pH calibration solution packets and place in aquarium water unopened to acclimate them to the system temperature If automatic temperature compensation is to be used place the temperature probe connected to the PM1 in the same aquarium water with the calibration packets From the Apex Display open the pH calibration menu Setup pH Setup pH Calibrate Use the up down arrow keys to choose the probe you wish to calibrate press Select or OK Use the up down arrow keys to select the value of the Low Calibration Solution used push Select Dry the Low Calibration Solution packet off and carefully open the corner of the low solution just enough to get the pH probe inserted in the packet 6 Remove the pH probe to be calibrated from the tank rinse it in probe storage solution or tap water gently shake the excess solution off the probe and place the probe in the Low Calibration Solution Periodically swirl the probe in the solution to ensure an accurate reading Ensure the probe is submerged in calibration solution at all times 7 Wait for the low reading to stop changing This may take a few minutes up to 5 minutes depending on the type and condition of pH probe being calibrated The value of the reading while calib
3. and discard the solution in the cap All new probes should be rinsed in clean tap water before placing in the aquarium Place the pH probe in an area with high flow that is continuously wet not an overflow that may drain dry for example Maintain a drip loop in the wire back to the Probe Module JI WARNING We do not recommend fully submerging the pH probe as this will cause the probe to fail prematurely NOTE Do not let the tip of the pH probe dry out as damage to the probe will result If you are not using your pH probe for an extended period of time make sure the tip is submerged in Probe Storage solution at all times If storage solution is not available tap water can be used RO DI water should not be used To enable the pH probe Apex Display Setup pH Setup pH Enable Use the up down arrow keys to choose the port you wish to configure press Select then use the up down arrow keys to select on off for that port press Save when done or Exit to discard changes Web Interface This option is not available from the Web Interface The pH probe can be configured to automatically adjust the pH to compensate for changes in tank temperature To enable disable this feature Apex Display Setup pH Setup Temp Comp Off Press Select to toggle temperature compensation on and off Web Interface This option is not available from the Web Interface NOTE If temperature compensation is to be used on the PM1 a temperature probe mus
4. Swx4_2 CLOSED Then OFF Please see the Programming Outlets section of the Apex Setup and Programming Guide for more information on programming the AquaController Apex NEPTUNE SYSTEMS LIMITED WARRANTY Neptune Systems warrants this product to be free from defects in material and workmanship for a period of 1 year from the date of purchase Probes carry a 90 day warranty If repair or adjustment is necessary and has not been the result of abuse misuse or accidental damage within the 1 year period please return the product with proof of purchase and correction of the defect will be made without charge For your protection items being returned must be carefully packed to prevent damage in shipment and insured against possible damage or loss Neptune Systems will not be responsible for damage resulting from careless or insufficient packaging Before returning please obtain a return authorization RMA number from Neptune Systems Returned merchandise will not be accepted without a RMA number Except for the warranty set forth above Neptune Systems is not responsible for any damages including but not limited to consequential damage occurring out of or in connection with the delivery use or performance of Neptune Systems products Buyer s remedies for breach of warranty shall be limited to repair or replacement and full or partial adjustment to purchase price 105 Cochrane Circle Suite L Morgan Hill CA 95037 http www neptunesys com S
5. er damage will void your warranty Mount all modules in locations safe from moisture y exposure INITIAL CONNECTIONS Plug one end of the included AquaBus cable into one of the AquaBus ports on the probe module and the other end into an available AquaBus port on your existing Apex system It makes no difference which AquaBus port is used and you do not need to power down the system when connecting AquaBus accessories as the system is plug and play WARNING NEVER plug standard USB devices into any AquaBus connector or AquaBus accessories _ 3 into computer USB ports Damage to the AquaBus accessory and or USB device may result AquaController Apex Probe Module 1 Setup Guide Page 1 Connect the pH or ORP probe must be purchased separately available from your Neptune retailer to the port labeled pH ORP on the Probe Module 1 Push the BNC female connector on to the male connector and turn turn clockwise to lock the connector in place If you are using a temperature probe with the Probe Module 1 must be purchased separately available from your Neptune retailer plug in to the port labeled Temp on the probe module and place the other end of the Temperature Probe in the aquarium water in an area of medium to high flow NOTE The temperature probe needs to be in the same area as the pH probe if temperature compensation is to be used STARTUP As soon as the probe module is connected to an active AquaBus the probe module will powe
6. g This may take a few minutes up to 5 minutes depending on the type and condition of ORP probe being calibrated The value of the reading while calibrating may not match the value of the solution being used this is normal Once the reading has stabilized press Select or OK 8 The Apex system will use the calibration measurements to calibrate the ORP probe 9 The calibration fluid can be used to calibrate more than one probe however the ORP calibration fluid should be discarded after use as they will degrade over time after opening If the calibration measurements were not accurate or were out of range the calibration may fail which will be indicated on the Apex Display In this case the default calibration settings will be used You can attempt the calibration procedure again however this usually indicates that the ORP probe is too far out of range and Should be replaced ORP PROBE MAINTENANCE ORP probes should be periodically cleaned for best performance The period between cleanings is up to the user but typically every 1 3 months is normal To clean the probe gently brush the sides and tip of the probe with a soft brush to remove any debris Rinse the probe in tap water Soaking the probe in acid vinegar or alkali borax solution to remove mineral deposits is not typically needed but can be used to try and bring back an old probe that has stopped working SWITCH INPUTS The PM1 has a Mini DIN8 connector for switch inputs labeled I O
7. let program If Switch1 CLOSED Then ON See the section titled Appendix 3 Programming Reference and Appendix 4 Advanced Programming Examples in the Apex Setup and Programming Guide for more information PROGRAMMING pH probes connected to probe modules will be identified as pHx3 pHx4 and so on The number in the probe name corresponds to the AquaBus address assigned to the probe module ORP probes connected to probe modules will be identified as ORPx3 ORPx4 and so on The number in the probe name corresponds to the AquaBus address assigned to the probe module If a temperature probe is connected to the probe module it is identified as Tmpx3 Tmpx4 etc with the same AquaBus number as the pH ORP probe Switch inputs connected to probe modules will be identified as Swx3_2 Swx5_3 etc The first number in the switch name corresponds to the AquaBus address assigned to the probe module The second number corresponds to the switch input number 1 6 NOTE The pH and ORP readings from the PM1 can be added to the Apex Display and Web Interface Status Screens See the section titled Display Setup in the Apex Setup and Programming Guide for more information AquaController Apex Probe Module 1 Setup Guide Page 7 The following are some valid program statements assumes that probe module is installed and configured on AquaBus address 4 If pHx4 gt 8 20 Then ON If ORPx4 gt 400 Then ON If
8. module to update push Select to update Web Interface Configuration Module Setup in the Module Configure area in the Module box select the Apex module to update from the dropdown list click the Update Firmware radio button click the Submit Module Update button a new browser window will open to display the update status CONFIGURE THE PM1 The PM1 includes one standard Apex temperature probe port temperature probe not included available from your Neptune retailer and a galvanically isolated port that can support either a pH or ORP probe Once the PM1 is connected to the AquaBus of your Apex system the system will automatically add the PM1 to the Apex configuration If you wish to use the PM1 port for a pH probe follow the steps listed in the section AquaController Apex Probe Module 1 Setup Guide Page 2 x titled pH Probe Setup below If you intend to use an ORP probe skip to the section titled ORP Probe Setup later in this manual PH PROBE SETUP pH probes connected to probe modules will be identified as pHx3 pHx4 and so on The number in the probe name corresponds to the AquaBus address assigned to the probe module If not already done connect the pH probe must be purchased separately available from your Neptune retailer to the port labeled pH ORP on the PM1 Push the BNC female connector on to the male connector and turn turn clockwise to lock the connector in place Remove the cap from the pH probe
9. nal quality aquarium controller at hobbyist prices The AquaController Apex is the most flexible expandable system on the market today FEATURES e Monitor pH or ORP e Control outlets based on pH or ORP readings from the probe connected to the PM1 e Automatic temperature compensation for pH with connected temperature probe temperature probe optional e Monitor and control temperature with connected temperature probe temperature probe optional e Galvanic Isolation for accurate and reliable probe readings e 6 digital inputs for float switches water on the floor sensors pressure sensors etc e Full data logging and graphing through the Apex Base Module e The PM1 attaches to and is powered by the Apex system via AquaBus e Automatic Plug N Play for easy setup and configuration e Upgradeable firmware through AquaBus via the Apex Base Module e Multi color LED Status Indicator e 2 AquaBus ports for flexible system connections e Comes with a 3 AquaBus cable e Compatible with Apex and Apex Lite systems PHYSICAL INSTALLATION The AquaController Probe Module 1 should be securely mounted in a location free from moisture Use wood screws through the mounting tabs of the probe module case or if mounting on drywall use drywall anchors mounting hardware not included e Mount all modules above the water line of the aquarium e Be sure to utilize drip loops on all power cords AquaBus cables and probe cables A WARNING Wat
10. nsed in clean tap water before placing in the aquarium Place the ORP probe in an area with high flow that is continuously wet not an overflow that may drain dry for example Maintain a drip loop in the wire back to the Apex Base or Probe Module NOTE New ORP probes typically read low and require a break in period It may take as long as a week to break in the ORP probe During this break in period control functions based upon ORP are not recommended WARNING We do not recommend fully submerging the ORP probe as this will cause the probe to fail prematurely To enable ORP probes Apex Display Setup ORP Setup ORP Enable Use the up down arrow keys to choose the port you wish to configure press Select then use the up down arrow keys to select on off for that port press Save when done or Exit to discard changes Web Interface This option is not available from the Web Interface ORP PROBE CALIBRATION ORP probes do not need to be calibrated to operate properly they should operate normally for the life of the probe without calibration However the AquaController Apex includes the ability to perform a 2 point calibration if desired Special calibration solution must be made from standard pH 4 0 and 7 0 calibration solution by dissolving Quinhydrone powder in the solutions Simply dissolve Quinhydrone powder into the 4 0 and 7 0 solutions until the powder no longer dissolves Adding too much powder does not harm anything it just
11. r up and begin to initialize When first connected to an AquaController Base Module through the AquaBus the probe module will automatically be assigned an AquaBus address and be added to the AquaController configuration The LED Status indicator on the probe module will flash yellow while it is being initialized Once initialized the LED Status indicator will be solid green The LED Status indicator will flash yellow when the probe module is powered on and communication with the AquaController Base Module is lost VERIFY THE INSTALLATION Verify the probe module was initialized and added to the AquaController Apex configuration Apex Display Setup Module Setup Modify Name from this screen you can see all AquaBus modules installed on the system Web Interface Configuration Module Setup Verify the probe module is listed in the Apex Module List UPDATE PROBE MODULE FIRMWARE A new version of firmware for probe modules may be included with Apex Base Module firmware updates You should check the firmware version status when the probe module is first installed and after updating the AquaController Base Module firmware See the section titled Updating Firmware in the AquaController Apex Setup and Programming Guide for instructions to update AquaController Apex Base Module and probe module firmware To check or update an Apex module firmware Apex Display Setup Module Setup Update Module use the up down arrows to highlight the Apex
12. rating may not match the value of the solution being used this is normal Once the reading has stabilized press uBR WN Select or OK 8 Use the up down arrow keys to select the High Calibration Solution used push Select 9 Dry the High Calibration Solution packet off and carefully open the corner of the low solution just enough to get the pH probe inserted in the packet 10 Remove the pH probe from the Low Calibration Solution rinse it in probe storage solution or tap water gently shake the excess solution off the probe and place the probe in the High Calibration Solution Periodically swirl the probe in the solution to ensure an accurate reading Ensure the probe is submerged in calibration solution at all times 11 Wait for the high reading to stop changing This may take a few minutes up to 5 minutes depending on the type and condition of pH probe being calibrated The value of the reading while calibrating may not match the value of the solution being used this is normal Once the reading has stabilized press Select or OK 12 The Apex system will use the calibration measurements to calibrate the pH probe 13 The calibration fluid can be used to calibrate more than one probe however the pH calibration fluid should be discarded after use as they will degrade over time after opening AquaController Apex Probe Module 1 Setup Guide Page 4 N If the calibration measurements were not accurate or were out of range the calib
13. ration may fail which will be indicated on the Apex Display In this case the default calibration settings will be used You can attempt the calibration procedure again however this usually indicates that the pH probe is too far out of range and should be replaced PH PROBE MAINTENANCE pH probes should be periodically cleaned and recalibrated for best performance It is not recommended to clean the probes unless calibration is to be performed The period between cleanings is up to the user but typically every 1 3 months is normal To clean the probe gently brush the sides and tip of the probe with a soft brush to remove any debris Rinse the probe in tap water Soaking the probe in acid vinegar or alkali borax solution to remove mineral deposits is not typically needed but can be used to try and bring back an old probe that cannot be calibrated Typical lifespan for a pH probe in aquarium use is 12 24 months ORP PROBE SETUP ORP probes connected to probe modules will be identified as ORPx3 ORPx4 and so on The number in the probe name corresponds to the AquaBus address assigned to the probe module If not already done The ORP probe is connected to the port labeled pH ORP on the PM1 Push the BNC female connector on to the male connector and turn turn clockwise to lock the connector place To remove the probe turn turn counter clockwise and gently pull the connector straight off the base module All new probes should be ri
14. t be connected and enabled on the PM1 The system temperature probe cannot be use for temperature compensation of a probe connected to a PM1 PH PROBE CALIBRATION pH probes need to be calibrated to perform properly The following procedure should be repeated periodically to keep your pH reading accurate as pH probes tend to drift out of calibration over time As the pH probe ages it will drift out of calibration very quickly or may not be capable of being calibrated at all If this occurs it will be necessary to replace the pH probe NOTE If you wish to use the automatic temperature compensation feature you should enable it before calibrating your pH probes In this case it is important for the calibration solution to be at the same temperature as the temperature probe at calibration time Also a temperature probe must be connected and AquaController Apex Probe Module 1 Setup Guide Page 3 enabled on the PM1 The system temperature probe cannot be use for temperature compensation of a probe connected to a PM1 The Apex system uses a 2 point calibration system which results in very accurate readings between the 2 points and less accurate readings outside the points Choose the calibration solutions based on the range of pH the probe is expected to read See the table below for recommended calibration solutions Expected Low High Fresh Water 6 0 7 5 4 0 7 0 Pr O O Salt Water 7 8 8 5 7 0 10 0 Aquarium Calcium Reactor 6 5 7
15. upport neptunesys com Phone 408 779 4090 Fax 408 762 2042 2013 Neptune Systems All Rights Reserved PM1 Manual V3 AquaController Apex Probe Module 1 Setup Guide Page 8 NEP TUNE SYSTEMS CE DECLARATION OF CONFORMITY Manufacturer Neptune Systems LLC 105 Cochrane Circle Suite L Morgan Hill CA 95037 408 779 4090 Product pH ORP Temperature I O Expansion Module Model No PM1 The undersigned hereby declares on behalf of the Neptune Systems LLC of Morgan Hill California that the above referenced product to which this declaration relates is in conformity with the provisions of e EN 60950 1 A1 2009 e EN 60335 1 2010 The Technical Construction File required by this Directive is maintained at the corporate headquarters of Neptune Systems LLC 105 Cochrane Circle Suite L Morgan Hill California The symbol to the right means that according to local laws and regulations your product should be disposed Curt Pansegrau of separately from household waste When this product reaches its end of life take it to a collection President point designated by local authorities Some collection C points accept products for free The separate collection and recycling of your product at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment AquaController Apex Probe Module 1 Setup Guide Page 9
16. wastes the powder AquaController Apex Probe Module 1 Setup Guide Page 5 To calibrate an ORP probe 1 Create the ORP 4 0 and 7 0 solutions as described above 2 From the Apex Display open the ORP calibration menu Setup ORP Setup ORP Calibrate 3 If you have more than one ORP probe enabled on your system use the up down arrow keys to choose the probe you wish to calibrate press Select or OK 4 Remove the ORP probe to be calibrated from the tank rinse it in tap water gently shake the excess water off the probe and place the probe in the 7 0 Quinhydrone Calibration Solution Periodically swirl the probe in the solution to ensure an accurate reading Ensure the probe is submerged in calibration solution at all times 5 Wait for the 7 0 Quinhydrone reading to stop changing This may take a few minutes up to 5 minutes depending on the type and condition of ORP probe being calibrated The value of the reading while calibrating may not match the value of the solution being used this is normal Once the reading has stabilized press Select or OK 6 Remove the pH probe from the 7 0 Quinhydrone Calibration Solution rinse it in tap water gently Shake the excess water off the probe and place the probe in the 4 0 Quinhydrone Calibration Solution Periodically swirl the probe in the solution to ensure an accurate reading Ensure the probe is submerged in calibration solution at all times 7 Wait for the high reading to stop changin
17. y NEP TUNE SYSTEMS AquaController Apex Probe Module 1 Setup Guide Table of Contents PROBE MODULE 1 INTRODUCTION cccccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeoeeeeeeeeeeeeeeeeeenanees FEATURES ui nce tcsapu enstnsacadsieiu unete a calsseiutungcn wcelsie w wnacaiateisiniwluigcajmcelsie w uiecaiatelsinim u acajmtelsie w wiecaeielsinis e aca wieloie w kiacae eleinls sietniweisie w wisiaieiaie PHYSICAL INSTALLATION oooooccccccococccnnnnnnnoooocorrnn nn nn cnn rrnn nn nn nnnnnnnnnnrrannnanannnnnanss Mtlal EONRECcUONS ca ds ios LAP CUNO eae E N E E A A E E cd eKey VERIFY THE INSTALLATION o ooocccccccocccnnnnnnccoocccrononnnnnnnnnnnnnonoorrrnnnnnnnnnnnnnnnnnnnrrnnnnnnnannnnnnass UPDATE PROBE MODULE FIRMWARE cccccccccccceeeeeeeeeeneneeeoeeeeeeneeeeeeeeeeannooooeeeeeneeeeeeeeas CONFIGURE TH PMiluoi a a A A PH PROBE SETUP cuusinia PIRProDe CalbraO Maso DA Probe Maintenance nta a Geant O ORP PROBE SETUP ssicinn ORP Prope CaliDratl Menea a a aaa aos ORP Prope Maintenance titi iaa AA AA AA ia SWITCH INPUTS A a daa PROGRAMMING isis NEPTUNE SYSTEMS LIMITED WARRANTY ccionn aaa N PROBE MODULE 1 INTRODUCTION Congratulations on your purchase of the AquaController Apex expansion accessory The AquaController Apex Probe Module 1 expands the monitoring and control capabilities of your Apex system by adding pH or ORP and temperature probe ports The AquaController Apex System delivers an expandable professio
Download Pdf Manuals
Related Search
Related Contents
Contrat registraire Annexe 1 Contrat d`interface instrucciones de montaje de tanque Eveready EV2PC2 User's Manual 32GSD3000 - BrandsMart USA Product Manual em-pulse-led-strobe-manual 自走式スクリーン ストラブ・グリップ 316タイプ GINA-Development - ESA Microelectronics Section Prog NoTPulm 15 - Académie Internationale de Pathologie USER MANUAL Copyright © All rights reserved.
Failed to retrieve file