ds-2mlf-av8a-ac8a-ai-200-v10 - Honeywell Process Solutions

image

Contents

1. NIO FIO UIQ AZO w 2 2MLF AC8A 4 20mA O 20mA Description gt Displays the operation status of 2MLF AV8A AC8A On Operation normal Blinks Error occurs Refer to 7 1 for more details Off DC 5V disconnected 2MLF AV8A AC8A module error gt Analog input terminal whose respective channels can be connected with external devices RUN LED Terminal amp xeer 2MLF ACBA 1 2MLF AV8A AC8A 1 Use the cable of 2 core twisted shield AWG 22 is recommended for the cable FEFFE standard 2 2MLF AC8A s input resistance is 250 Q typ Unit mm Pre on or Handling 3 2MLF AV8A s input resistance is 1 MQ min li Z 1 Do not drop or give impact on the product l UOU UUU A 2 Do not detach PCB from the case it may cause malfunction Om O O a o e T 3 During wiring or other work do not allow any wire chips get inside the product 7 1 I O area of A D converted data 4 Switch off the external power before mounting or removing the module and z 7 Device Details RW Sign 7 3 the cable
2. setting gt Respective input ranges can be set based on channels 1 Voltage Type Analog input Digital outpu 1 5V 0 5V 0 10V 10 10V Unsigned Value 0 16000 Signed Value 8000 8000 1000 10000 Precise Value 5000 0 5000 0 10000 10000 Percentile Value 0 10000 Digital output 2 Current Type alog input 9 7 Digital output 4 20 mA U 20 mA Unsigned Value 0 16000 Signed Value 8000 8000 Precise Value 4000 20000 0 20000 Percentile Value 0 10000 gt 16 bit binary value data 14 bits gt Format of digital output data can be set through user program or S W package respectively based on channels Analog input range Resolution 1 16000 Analog input range Resolution 1 16000 The max 4 20mA 1 0 yA resolution I 10V 0625 n 625 m A0 10V 1 250 mV ales ail Ac urac 0 2 or less when ambient temperature is 25 C 5 C y 0 3 or less when ambient temperature is 0 C 55 C Max conversion speed 250 us channel Absolute max HBV 30 mA input H _ Analog 8 channels 1 module input points Insulation method Photo coupler insulation between input terminal and PLC power no insulation between channels Terminal f connected 18 point terminal 9 poins Fixed point assignment 64 Variable point assignment 16 occupied Internal consumed ESV A current Weight 140g 1 When A D conversion module is r
3. 2 2245 1000 Fax 886 2 2245 3241 For Countries SE Asia Listed below call Honeywell Singapore Office Pakistan Cambodia Laos Myanmar Vietnam and East Timor For Countries Listed below call Honeywell India Office Bangladesh Nepal and Sri Lanka Honeywell Safety Precautions gt Safety Precautions is for using the product safe and correct in order to prevent the accidents and danger so always follow the instructions gt The precautions explained here only apply to the 2MLF AV8A and 2MLF AC8A unit For safety precautions on the PLC system refer to the MasterLogic 200 CPU User s manual gt The precautions are divided into 2 sections Warning and Caution Each of the meanings is represented as follows Wa rning If violated instructions it may cause death fatal injury or considerable loss of property If violated instructions it may cause a slight injury or slight loss of Before handling the product Before using the product read the datasheet and the User s manual through to the end carefully in order to use the product efficiently MasterLogic 200 User s Manual Name Code 2MLK CPUH CPUS User s manual 10310000648 3 Performance Specifications Performance specifications of A D conversion module are as specified in Table Item Specification 2MLF AV8A Voltage Type 2MLF AC8A Current Type DC1 5V DCO 5V DC 4 20 ma Analog input DCO
4. assigned direction UXY 00 0 Module ERROR flag UXY 00 F Module READY flag R endl UXY 01 0 CHO Run flag UXY 01 1 CH1 Run flag ee UXY 01 2 CH2 Run flag UXY 01 3 CH3 Run flag UXY 01 4 CH4 Run flag R AD CPU S UXY 01 5 CH5 Run flag UXY 01 6 CH6 Run flag UXY 01 7 CH7 Run flag A UXY 03 CH1 digital output value R CO 6 1 Precautions for wiring UXY 04 CH2 digital output value R L 1 Do not place AC power line near to A D conversion module s external input UXY 05 CH3 digital output value R AID CPU d m ar i ne UXY 06 CH4 digital output value R CET 0 sign line With an enough distance kept away between it will be free from TAT eae donal outu val aD m i igital output value i p 1 E ea in due consideration of ambient temperature and awe CHG digital output value R law 7 es P UXY 09 CH7 digital output value R 98 82 27 allowable current whose size is not less than the max cable standard of UXY 10 0 Flag to detect CHO disconnection 1 5 V or 4 20 mA bai ra es ee AWG22 0 3m UXY 10 1 Flag to detect CH1 disconnection 1 5 V or 4 20 mA 3 Do not place the cable too close to hot device and material or in direct contact UXY 10 2 Flag to detect CH2 disconnection 1 5 V or 4 20 mA with oil for long which will cause damage or abnormal operation due to short ane a i pe ee aen i EA A R AID CPU circuit UXY 10 5 Flag to detect CH5 disconnection 1 5 V or 4 20 mA 4 Check the polarity when wiring the terminal
5. UXY 10 6 Flag to detect CH6 disconnection 1 5 V or 4 20 mA 5 Wiring with high voltage line or power line may produce inductive hindrance UXY 10 7 Flag to detect CH7 disconnection 1 5 V or 4 20 mA causing abnormal operation or defect UXY 11 0 Flag to request error clear Ww CPU A D
6. 10V DC 0 20 ma DC 10 10 V Input Resistance 250 Q A Caution products gt The symbols which are indicated in the PLC and User s Manual mean as follows Gives warnings and cautions to prevent from risk of injury fire or malfunction h Gives warnings and cautions to prevent from risk of electrical shock gt Store this datasheet in a safe place so that you can take out and read whenever necessary Always forward it to the end user Z N Warning gt Do not contact the terminals while the power is applied Risk of electric shock and malfunction gt Do not drop or insert any metallic object into the product Risk of fire electric shock and malfunction gt Do not charge heat short solder and break up the battery Risk of injury and fire by explosion and ignition Z N Caution gt Before wiring the PLC ensure to check the rated voltage and terminal arrangement for the module and observe them correctly Risk of electric shock fire and malfunction Tighten up the terminal screw firmly to defined torque when to wire the PLC Risk of fire and electric shock if the terminal screw looses Use the PLC in an environment that meets the general specifications contained in this datasheet Risk of electrical shock fire erroneous operation and deterioration of the PLC Be sure that external load does not exceed the rating of output module Risk of fire and erroneous operation Do not use the PLC in the enviro
7. Honeywell ATASHEET MasterLogic 200 AD Conver 2MLF AV8A 2MLF AC8A 10310000612 Printed in Korea For more information on MasterLogic PLCs contact your nearest Honeywell office Australia Japan Honeywell Ltd Honeywell Inc Phone 61 2 9353 4500 Phone 81 3 5440 1395 Fax 61 2 9353 7677 Fax 81 3 5440 1368 China South Korea Honeywell Tianjin Ltd Beijing Honeywell Co Ltd Phone 86 10 8458 3280 Phone 82 2 799 6114 Fax 86 10 8458 3102 Fax 82 2 792 9015 Honeywell Tianjin Ltd Shanghai Phone 86 21 6237 0237 Fax 86 21 6237 3102 Malaysia Phone 603 7958 4988 Fax 603 7958 8922 Indonesia PT Honeywell Indonesia Phone 62 21 535 8833 Fax 62 21 5367 1008 New Zealand Honeywell Ltd Phone 64 9 623 5050 Fax 64 9 623 5060 India Honeywell Automation India Ltd Phone 91 20 5603 9400 Fax 91 20 5603 9800 Philippines Honeywell Systems Inc Phone 63 2 633 2830 Fax 63 2 638 4013 Honeywell Co Ltd Honeywell Process Solutions 17F Kukje Center Building 191 Hangangro 2ga Yongsan gu Seoul 140 702 Korea Tel 82 2 799 6114 Fax 82 2 792 9015 Email MasterLogic honeywell com 10310000612 Printed in Korea Honeywell Engineering Sdn Bhd Singapore Honeywell Pte Ltd Phone 65 6355 2828 Fax 65 6445 3033 Thailand Honeywell Systems Ltd Phone 662 693 3099 Fax 662 693 3085 Taiwan Honeywell Taiwan Ltd Phone 886
8. eleased from the factory Offset Gain value is adjusted for respective analog input ranges which is unavailable for user to change 2 Offset Value Analog input value when digitalized value is 0 in case that the range of digitalized value is 0 16000 3 Gain Value Analog input value when digitalized value is 16000 in case that the range of digitalized value is 0 16000 6 2 Wiring Example g P 7 2 A D Setting area of Run parameters Respective designations of the parts are as described below 1 2MLF AV8A 1 2MLF AV8A 2MLF AC8A Memory address Details Remarks Hex Dec Specify channel to use PUT Specify range of input voltage current PUT Specify range of output data PUT Specify filter process PUT Specify CHO filter constant Specify CH1 filter constant Specify CH2 filter constant Specify CH3 filter constant Specify CH4 filter constant Specify CH5 filter constant Specify CH6 filter constant ews Specify CH7 filter constant we 2MLF AVBA Specify average process Specify average processing method 4 2 Specify CHO average value i Specify CH1 average value Specify CH2 average value Specify CH3 average value Specify CH4 average value Specify CH5 average value Specify CH6 average value Specify CH7 average value Error code Co SERE 2MLF AV8A 2MLF AC8A RUN RUN 4 j ojaa jvjinj o O NIO I0 ozo
9. nment of direct vibration Risk of electrical shock fire and erroneous operation Do not disassemble repair or modify the PLC Risk of electrical shock fire and erroneous operation When disposing of PLC and battery treat it as industrial waste Risk of poisonous pollution or explosion Precautions for use gt Do not install in any places other than PLC controlled place gt Ensure that the FG terminal is grounded with class 3 grounding which is dedicated to the PLC Otherwise it may cause disorder or malfunction of PLC gt Connect expansion connector correctly when expansion modules are needed Do not detach PCB from the case of the module and do not modify the module gt Turn off the power when attaching or detaching module gt Cellular phone or walkie talkie should be farther than 30cm from the PLC gt Input signal and communication line should be farther than minimum 100mm from a high tension line and a power line in order not to be affected by noise and magnetic field MasterLogic 200 Basic instruction manual 10310000649 MasterLogic 200 Software manual 10310000650 2MLF AV8A AC8A User s manual 10310000616 adil n A D conversion module designed for MasterLogic 200 series is used to convert analog signal voltage or current input to the digital value of signed 16 bit binary data data 14 bits specified in MasterLogic 200 CPU modules General specifications of MasterLogic 200 se
10. ries are as specified in Table Related Item Specification eee specifications 0c 55 C 25 C 70 C 5 95 RH Non condensing 5 95 RH Non condensing For discontinuous vibration Frequency Acceleration Amplitude 10Sf lt 57Hz 0 075mm 57sfs150HZ 9 8m s2 1G For continuous vibration Frequency Acceleration Amplitude XYZ fos57Hz 0 035mm rections 57 lt f lt 150Hz 4 9m s2 0 5G Operating temp Storage temp Operating humidity Storage humidity Number Each 10 times in Vibration 1EC61131 2 Max impact acceleration 147ms 15G Authorized time 11ms Pulse wave Sign half wave pulse Each 3 times in X Y Z directions Square wave impulse noise Shocks 1EC61131 2 1 500V z Voltage 4kV contact IEC61131 2 discharging IEC61000 4 2 27 500MHz 10 Vim IECEII31 2 IEC61000 4 3 Class Digital Analog I O Transient module communication interface IEC61131 2 burst IEC61000 4 4 noise Voltage 2kV 1kV Electrostatic discharging Radiated electromagnetic field noise Fast Power Ambient conditions Operating height 2000m or less Pollution degree 2 or less No corrosive gas or dust Cooling method Self cooling Input Resistance 1 MQ min Analog input range Analog input range can be selected through user program or Software package

Download Pdf Manuals

image

Related Search

Related Contents

PDF Version - License Dashboard  Sharp AL-2020 Specifications  bureau du comite scientifique homologation des colloques  INSTALLATION COMPLETION CHECKLIST One motor system  529 College Savings Plan Submission Manual  仕様書  Olympus VN-240 Digital Voice Recorder  MALA ILL & Courier Manual. - Mid  Fujitsu ESPRIMO E420 E85+  HP PROCURVE 3400CL-24G User's Manual  