Home
11196_System57_EIS Install Guide_MAN0445_Issue9_06
Contents
1. 10 The installation has completed successfully click OK MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 4 RUNNING THE ENGINEERING INTERFACE SOFTWARE To run the Engineering Interface Software proceed as follows 1 From the Program Manager display select Sieger Applications and then double click the System 57 EIS_vx y icon or Click on Start select Programs Sieger Applications and then the System 57 EIS_vx y SYSTEM 57 Engineering Interface Software 2 Check that the display shows Pa Syilem 57 Fngineciing InlerGice Sofware lt Untilled gt Ele Mon Gstionc S2 elkumbers Comm Helo Main Menu H slcger A SL e Ts t 1 ie ENG 5 mn img iaag si lsri fas 3 S DERVENI eal Wea E E HEH e orua bsa oc Ki brul bzul bul brul bsn Tow gt gt gt Canfigure Rack aor View j Print Channel Details Read Hack Program Hack Program Cards 10 MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 5 HELP MENUS 5 1 GENERAL The System 57 EIS has a comprehensive on line help facility available for the operator to use thus eliminating the need for an additional manual The help facility is available from the pull down menu on the Main Menu Configure Rack and View Print Channel Details screens The following options are available Search for help on How to
2. A03132 21 22 5 HELP MENUS Most changes to the control cards are implemented once the programming is complete by an automatic software reset of the card s that were reprogrammed Certain changes however require the control cards to have a power on reset before the changes are implemented These type of changes are indicated in the highlighted box of the EIS display after reprogramming is complete To reset these control card changes either switch off the power supply to the whole system or undo the two control card front panel securing screws and using the extraction tool partially pull the card s out of the rack and then reinsert the card Secure the control card s back in the rack with the two front panel securing screws Reconfiguration is now complete MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 USER NOTES MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 USER NOTES MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 USER NOTES Find out more www honeywellanalytics com Contact Honeywell Analytics Europe Middle East Africa India Life Safety Distribution AG Weiherallee 11a CH 8610 Uster Switzerland Tel 41 0 44 943 4300 Fax 41 0 44 943 4398 gasdetection honeywell com Americas Honeywell Analytics Inc 405 Barclay Blvd Lincolnshire IL 60069 USA Tel 1 847 955 8200 Toll free 1 800 538 0363 Fa
3. following actions From the main menu select Configure Rack Highlight the control card that requires the configuration change by clicking the left mouse button once with the mouse pointer over the required control card and then selecting Configure Selected Card or Click the right mouse button once with the pointer over the required card 13 MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 5 HELP MENUS 9 A series of screens are available which are selectable from the titles shown on the right hand side of the screen Clicking the left mouse button once with the pointer on a title will cause that tiltles parameters that may be modified by the EIS to be displayed H sieger ses Oa eee ta CardTppa Slot No Lenn gure carat CNN S Output Made 5704 1 CIRAlim amp Current Inap 1020354 420m4 Currcnt Loap I Fnshle Filler T Filles Falur 0 between 90mA and 915mA Faull Hulpat evel Genernl Bridge Currant fe Enabled ees 200 mA Alarms fee zat Inhih luput evel nf E Penn 2 0 ma Curmplex Alr 4 20m4 Senser Dive Sonticuvation chen 1 Lanp Inbihd I ewed Max 2 0 u edat T Loop Inhibit Enabled A Lanp Inhih I evel Min 1a E Limits _Cancel_ 10 The required parameters can now be changed 11 If other control cards require changes these can SE CardType Slot No accessed using the up lt and down V buttons at the 5704 to
4. 11 5 3 How to Use System 57 EIS 12 5 4 Context Sensitive Help F1 12 6 Operation Overview 13 MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 1 INTRODUCTION The System 57 Engineering Interface Software EIS is used to set the System 57 Control System rack configuration and operating parameters The Setup Procedures are carried out on a PC which provides serial data communication with the rack The software allows the rack configuration and parameters to be set using either a mouse and keyboard or direct from a prerecorded data file The necessary EIS required to run these procedures is provided on a USB flash drive and should be installed as indicated in the following sections Before the installation of the EIS however ensure the computer meets the minimum requirements and that the EIS package contains the required information Once installed the configuration software is ready for use To help the user to learn how to use the software a comprehensive on line HELP system has been incorporated therfore no separate user manual has been written WARNING The operation of the whole system depends on the configuration made using the EIS Inappropriate settings may affect the safety critical operation of control cards or the whole system The software shall only be used by persons familiar with the operation of gas detection devices and in particular with the operation of System 57 Default setting
5. ADME FILE Where there have been changes to the software since publication of the manual these changes are listed in a separate README file MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 3 INSTALLING THE ENGINEERING INTERFACE SOFTWARE Check the disk for a README file and if one is present read the file for any new information before installing the software To start SETUP proceed as follows Insert the USB Flash drive into any available USB port For Windows XP operating systems Autoplay will be initiated Select Run System 57 EIS setup from the menu then click OK If for any reason the steps above fail or you are using an Operating System other than Windows XP then the setup application can be run manually Goto My computer select and open Removable disk by double clicking it with the left mouse button Navigate through the directories EIS_5v4 Setup exe and run the setup application The following window will be displayed ENGINEERING INTERFACE SOFTWARE User Name Company Name Serial Number Install Exit MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 3 INSTALLING THE ENGINEERING INTERFACE SOFTWARE 6 Enter USER NAME COMPANY NAME and SERIAL NUMBER Note The serial number can be found on a sticker attached to the USB Flash Drive If installing a software upgrade version use the same seria
6. Installation Instructions SYSTEM 57 Engineering Interface Software System 57 Engineering Interface Software EIS MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 HELP US TO HELP YOU COPYRIGHT This software is the copyright of Honeywell Analytics Limited Users must not copy or distribute reverse engineer or otherwise misuse the software Users are granted licence to use it only for the purposes for which it was intended 2 HELP US TO HELP YOU Every effort has been made to ensure the accuracy in the contents of our documents however Honeywell Analytics Limited can assume no responsibility for any errors or omissions in our documents or their consequences Honeywell Analytics Limited would greatly appreciate being informed of any errors or omissions that may be found in the contents of any of our documents and to this end we include the form opposite for you to photocopy complete and return to us so that we may take the appropriate action MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 CONTENTS Section Page 1 INTRODUCTION 5 2 PERSONAL COMPUTER REQUIREMENTS 6 2 1 Hardware and System Requirement Check 6 2 2 Package Contents 6 2 3 Backup Copies Of Disk 6 2 4 Read the README File 6 3 Installing the Engineering Interface Software 7 4 RUNNING THE ENGINEERING INTERFACE SOFTWARE 10 5 HELP MENUS 11 5 1 General 11 5 2 Search For Help On
7. ion for a particular configuration parameter can also be accessed directly by selecting the area of the screen where the parameter is displayed and then pressing the F1 function key Note For the configuration menu screens this is the only method of entering the help faculities 12 MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 6 OPERATION OVERVIEW The following text is a brief overview of the procedure for reprogramming an existing configured rack of System 57 control cards This is typical for changing a particular setup facility A more comprehensive guide is given in the help facility with the EIS Start the System 57 EIS Connect the supplied cable to the PC and to the System 57 rack that requires reprogramming From the main menu selecty Read Rack The System 57 details will be read by the program and once completed the main menu virtual rack display will reflect the actual rack layout From the pull down File menu at the top of the screen select the Save rack As function Enter the name you wish to identify the rack configuration by maintaining the rck file extension and click on OK This saved file will be useful if difficulties are encountered while carrying out the following procedures and will enable the rack to be returned to its original configuration condition If reqired the PC can now be disconnected from the System 57 rack and moved to a more convenient area for the
8. l number that was supplied with the original installation disk o System 57 EIS Setup X Begin the installation by clicking the button below Click this button to install System 57 EIS software to the specified destination directory Directory C Program Files System 57 EIS Change Directory Exit Setup 7 Click the button to accept the default directory path or select an alternative by clicking the Change Directory button ic _ System 57 EIS Setup E Welcome to the System 57 EIS installation program T Setup cannot install system files or update shared files if they are in use Before proceeding we recommend that you close any applications you may be running Exit Setup MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 3 INSTALLING THE ENGINEERING INTERFACE SOFTWARE 8 Click OK to continue or Exit set up to abort installation Fi System 57 EIS Choose Program Group Setup will add items to the group shown in the Program Group box You can enter a new group name or select one from the Existing Groups list Program Group System 57 Els Existing Groups Accessories Administrative Tools Burm Electronics Workbench Startup System 57 EIS ce 9 Itis recommended that the default Program Group is accepted System 57 EIS Setup System 57 EIS Setup was completed successfully
9. p right of the screen O1O203 04 12 Once all changes have been completed click OK and the screen will return to the Configure Rack screen 14 MANO0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 13 14 15 16 17 18 19 20 5 HELP MENUS At this point additional control cards can be added to the rack The easiest way to configure these control cards is to copy an existing card configuration as follows a Highlight the control card to be copied b Select Copy Card Cc Highlight the free slot that the new card is to be fitted to d Select OK e Specific channels on 5704 control cards can be copied in a similar manner Once all changes have been completed click on Back and this will cause the display to return the the Main Menu screen From the pull down File menu at the top of the screen select the Save rack As function Enter a different name to identify the new rack configuration from the one used previously maintaining the rck file extension and click on OK Select Program Cards Click on each card that needs to be reconfigured One or a number of cards may be selected together Ensure that the PC is connected to the rack by the cable or reconnect the PC to the rack if disconnected at Step 6 Select OK This will start the reprogramming of the rack control cards MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003
10. s of sensor specific parameters should only be changed in exceptional justified circumstances Do not change any parameter unless its meaning is clearly understood Please contact Honeywell Analytics Limited if in doubt If the system is used according to the EC type examination certificate BVS 04 ATEX G 001 X observe the Special conditions for safe use as described in chapter 10 of the system manuals part numbers 05701 M 5001 for the 5701 control system and 05704 M 5001 for the 5704 control system MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 2 PERSONAL COMPUTER REQUIREMENTS 2 1 HARDWARE AND SYSTEM REQUIREMENT CHECK The software must be installed on a PC with the following recommended minimum requirements a 80486 33 MHz processor or better b Hard Disk with 3Mb free space C VGA or compatible screen d 8Mb RAM e Mouse f One unused communications port to allow the Engineering Card Serial Port of the System 57 Control System Rack to be connected to the computer g Microsoft Windows 95 2000 and XP 2 2 PACKAGE CONTENTS The following items are contained in the package a This Manual b PC to Rack Connecting Cable C EIS Software supplied on a USB Flash Drive Note The EIS software upgrade package does not include the PC to rack cable 2 3 BACKUP COPIES OF DISK Before installation it is recommended that a backup copy is made of the master disk 2 4 READ THE RE
11. use System 5 EIS About System 5 EIS 5 2 SEARCH FOR HELP ON Selecting Search for help on will cause cause a screen similar to the following to be displayed Help Topics Syslem 67 Fnginecting Inleriic BEA der Fre Zp tre lis fom lzttzre ol tre wor Soule bolig or 2 Lik Ihe index erty yan wanl nm Fen ies Dia ley S701 C a rial Cur igara wn a 5701 C arnel Co figuia ion AD avelaze E Arlon on arrer otic un Evert C esting clizn on Nee Even Aclive high Engineciicg Cad 3zrole inpul Alara evel ala ns Andoque Andogue Ou pul Mozuc MAN0445 Issue 09 06 09 Engineering Interface Software 05701 M 5003 A03132 5 HELP MENUS By typing a search word into the upper selection box or selecting a topic from the lower selection box and then selecting Display Show Topic the help titles for that subject will be highlighted A particular topic can then be highlighted and the Display Go To button operated Detailed help information on the selected subject will now be displayed 5 3 HOW TO USE SYSTEM 57 EIS SYSTEM 57 Engineering Interface Software BUT Cena puei WEI Looky reader Selecting will cause the following screen to be displayed Clicking on any of the displayed topics will display information relating to that topic with links that take the user into more detailed information and other related topics 5 4 CONTEXT SENSITIVE HELP F1 The help informat
12. x 1 847 955 8210 detectgas honeywell com Asia Pacific Honeywell Analytics Asia Pacific 508 Kolon Science Valley I 187 10 Guro Dong Guro Gu Seoul 152 050 Korea Tel 82 0 2 2025 0300 Fax 82 0 2 2025 0329 analytics ap honeywell com Technical Services EMEAI HAexpert honeywell com US ha us service honeywell com AP ha ap service honeywell com www honeywell com Please Note While every effort has been made to ensure accuracy in this publication no responsibility can be accepted for errors or omissions Data may change as well as legislation and you are strongly advised to obtain copies of the most recently issued regulations standards and guidelines This publication is not intended to form the basis of a contract Issue 9 06 2009 05701 M 5003_A03132 H_MANO445_EMEAI 2009 Honeywell Analytics Honeywell 11196
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 TI- 500E UG 30 ASUS RT-N16 HUG7709 User's Manual LAGOON 450 CT800 Treadmill Owner`s Manual Beta Test Site License - ExpORL 警告 注意 注意 - Azbil Corporation 第 11 自動火災報知設備 Notice du vélo TDK 4GB SDHC Copyright © All rights reserved.