RP-985, RP-1005 User`s Manual RP-985, RP
Contents
1. ccccccsecccseeeceeeeseeeseneessaees Disconnecting Hoses siecicadssswodaandvnccinapainen diay laniaesaresadseeideeseuteinae tat Hose CMG UNS seaseencascetstea lt accdesaaeence meee tancieecteranteasecleensaedoeniaeaneaaneses Filling amp Maintenance We St amp FINNO sorer n ai a Adding Coolers amp Maintenance ccccccecccceeeeeeeeeeeeeeeeeeeeees Troubleshooting aicsicec cece scan candenencecet eaacteenccennasancseoeanneatenedeteenanees Limited Warranty x 2sdee nce ctanee acc niamnscccertsntuesepsweapescecietsedsasienetestceat Kawase User Manual Included Hardware Temperature Sensors x3 ATX Pass Thru Wire Mounting screws ATX Jumper Wire User Manual Required Tools During installation you may need the following tools C a a pte r flat head screw driver ea S phillips head screw driver pliers long nose pliers Rp iii scissors _ iV pnra urme User Manual System Features Unit Diagram Reservoir Control Buttons Display Control Board Reservoir amp Pump The coolant tank is transparent for easy liquid level monitoring through the front window It is filled through a metal fill port on top The reservoir is illuminated by internal blue LEDs Control Board Behind the reservoir the Control Board is responsible for a number of tasks including powering the pump display radiator fans if attached and operating
2. ISO 9001 Printed in Korea This User Manual is updated regularly Please be sure to check our support page for a newer version of this guide www koolance com support GENERAL PRECAUTION Please read this manual carefully before beginning the installation of your Koolance system This manual assumes the user has basic experience in building and configuring computer systems Information referring to traditional hardware assembly is intentionally brief ABOUT SIGNS Throughout this document critical information is highlighted in gray colored boxes The following symbols are intended to help prevent any situation which may cause personal injury and or damage to equipment WARNING Indicates a potentially hazardous situation which if not avoided could result in personal injury or be life threatening CAUTION Indicates a potentially hazardous situation which if not avoided may result in damage to equipment or property PROHIBITED Indicates a prohibited action PROHIBITED USE This product is designed developed and manufactured as contemplated for general use including without limitation general office use personal use and household use but is not designed developed and manufactured as contemplated for use accompanying fatal risks or dangers that unless extremely high safety is secured could lead directly to death personal injury severe physical damage or other loss including without limitation nuclear power core co
3. To reset all temperature alarms to their default 55 C 131 F setting press and hold the C F button until dEF flashes in the display NOTE This will also reset the fan speed mode to auto and pump power to 100 If any sensor reaches 3 C 5 F above the alarm temperature the unit will trigger the ATX pass through wire relay For a computer this is equivalent to holding in the power button for several seconds to force shut down With default alarm settings this means the shutdown signal is sent if any sensor reaches 58 C 136 F block which is typically 5 10 C 9 18 F lower than the actual heat source This difference must be considered if adjusting alarm shut down temperatures Activating alarm shutdown modes at too high of temperature may be unsafe See Temperature Sensor Placement for information on attaching sensors CAUTION Generally sensors report liquid temperature at the water Mrawawee User Manual 5 Positioning the Unit The cooling unit is designed to operate in one orientation In other directions the pump and reservoir may not bleed properly and could lead to cavitation Chapter 2 p Installation Reservoir amp Pump Connections The rear of the unit accepts various connections to integrate with your cooling system IN OUT Liquid nozzle sockets Designed in the USA Made in Korma F Lee POWER E r m s i i L AP 1005 201251 l PUMP
4. POWER Connection from Internal pump connection power supply 12VDC ATX Wire lead for safety shutdown relay For FAN Radiator fan connections computer use leave the 2 pin wire connected 2 0A max per plug 3 0A total to NO Normally Open pins If this unit s relay feature see Alarm and TEMP Temperature sensors Shutdown Settings pg 4 will be used for an TONK on the front display application requiring a Normally Closed circuit move wire lead to NC Installation Koowance User Manual 7 Fan Connection This unit has two connections to power radiator fans Multiple fans can be combined into a single plug A fan wiring harness is optionally available from Koolance Power Connection The temperature sensors and ATX lead may come pre connected to your unit If not connect them per the diagram on page 7 Connect a 12 Volt 4 pin Molex plug from the power supply to the power connection on the rear of the unit CAUTION The total combined amperage of all fans connected to the unit can not exceed 3A The maximum load on a single fan header is 2 0A Installation ATX Pass Through Lead To Motherboard The ATX pass through lead is responsible for sending the shut down signal if any sensor reaches the preset shutdown temperature See Display Panel for configuration There is no polarity direction with the ATX lead Connect the male ATX power lead from the cooling unit to your computer
5. s main chassis power button From Cooling Unit Connect the female ATX power lead from the Slot Adapter to the motherboard s power switch connection often marked PWRSW PWSW or PWBT This is the connection that would normally receive the chassis power button directly CAUTION The auto shutdown safety feature of this product will not function without properly connecting the ATX pass through lead Temperature Sensor Placement Three surface temperature sensors are included with this product for monitoring Generally sensors are affixed blocks with metal tape Liquid temperature sensors are also available optionally from Koolance Sensors should never be placed directly between a heat source and its water block This will interfere with contact and can damage the sensor or heat source apm amre User Manual to water Nozzles Install the G 1 4 BSP threaded nozzles you purchased for your unit It s recommended to hand tighten all fittings to avoid damaging the unit will need to connect each to the rear nozzles y a Cut tubing into two segments You Each hose connection will use a threaded compression ring or hose clamp to keep it secure Be sure to thread the compression ring or hose clamp onto the hose before attaching it Squeeze the tube while pushing it firmly over the nozzle Tubing should completely cover the nozzle Wetting the end of the hose with war
6. the audio alarm and shutdown modes 9 System Features Display Panel safety settings such as audio alarm shutdown and pump speed Please be sure to configure your LED Display Panel properly or dam age to your computer data and or equipment could result f CAUTION This cooling system allows full user control of hardware Increase Setting Current Mode Value Decrease Setting Mode Select Display in C or F Modes There are seven display options All are reached by continually pressing the SET mode select button 1 Temperature sensor 1 is displayed 2 Temperature sensor 2 is displayed 3 Temperature sensor 3 is displayed 4 All temperature sensors are cycled automatically 5 Fan setting is displayed mode F is shown 6 Pump setting is displayed mode P is shown 7 All temperatures fan and pump settings are cycled automatically Temperature Sensors This cooling system can monitor up to 3 included temperature sensors The first LED digit indicates which sensor channel is currently displayed in the temperature reading To cycle through sensors press SET Fan Speed This option adjusts the radiator fan speed Higher speeds can improve performance but will produce more noise There is 1 automatic and 10 manual fan settings 1 10 From the fan F or any cycle mode press the Y or A buttons to adjust fan settings or hold down an arrow to skip to the lowest or highest mode dire
7. the most temperature critical Chipset a Block Video Cooling System Block Radiator Pump Reservoir Video CPU Block Block Parallel Loops Parallel loops are normally used to help accommodate water blocks with significantly disproportionate flow restriction They can become quite complicated and if not well planned may lower performance through added bottlenecks and pressure drop One suggestion for parallel loops is to reduce tubing size when splitting Ideally the hose area going into the splitter will be roughly equal to or slightly lower than the combined hose area coming out For example 3 8 10mm tubing split into two 3 8 10mm paths would lose more pressure than splitting from 3 8 10mm into two or three 1 4 6mm paths If you are considering a parallel flow path we would encourage you to experiment with different setups There may be more optimal configurations than the example shown below Cooling System Radiator Pump Reservoir 0 Q op Splitter 6mm RAM Block roe mm om es HD oc Block 12 Installation Disconnecting Hoses Nozzles are designed to attach tightly If you need to remove a hose for any reason it may not pull off easily even after unscrewing the compression fitting Usually a connection will come free by squeezing the hose on top of the nozzle and twisting pulling away If this fails cutting a small incision lengthwise parall
8. arranty service contact our RMA department for information The product must be shipped postage prepaid to an authorized Koolance service location It is suggested that for your protection you return shipments of product by insured mail insurance prepaid Damage occurring during shipment is not covered by this warranty Shipping costs are non refundable No other warranty written or oral is authorized by Koolance Incorporated Disclaimer INNO EVENT SHALL KOOLANCE INCORPORATED OR ITS EMPLOYEES AGENTS SUPPLIERS MANUFACTURERS OR CONTRACTORS BE LIABLE FOR ANY DAMAGES OF ANY KIND OR CHARACTER INCLUDING WITHOUT LIMITATION ANY COMPENSATORY INCIDENTAL DIRECT INDIRECT SPECIAL PUNITIVE OR CONSEQUENTIAL DAMAGES LOSS OF USE LOSS OF DATA LOSS OF INCOME OR PROFIT LOSS OF OR DAMAGE TO PERSONS OR PROPERTY CLAIMS OF THIRD PARTIES OR OTHER LOSSES OF ANY KIND OR CHARACTER AND WHETHER OR NOT THE POSSIBILITY OF SUCH LOSS OR DAMAGE HAS BEEN NOTIFIED TO KOOLANCE INCORPORATED 22
9. ctly Automatic mode will adjust the fans for you based on temperature values from sensor 1 This mode is reached by lowering the fan setting to 0 Aut A will be displayed Pump Speed There are 10 manual pump settings 1 10 From the pump P mode press apm amre User Manual 3 the V or A buttons to adjust pump settings or hold down an arrow to skip to the lowest or highest mode directly There is no automatic mode for the pump RP 1005 Manual Auto Mode Temperature Fan Duty Fan Power Pump Pump Mode REU Us Voltage Power 1 36 37 C 97 99 F 1 0 35 C 32 95 F 5 7 68 5 6 oae 040 8 44 45 C 111 113 F f WM ETAUE Auto Mode Temperature Duty Fan Power Range 0 35 C 32 95 F us o5 O7 2 ae ae ae te 2 20 24 28 36 44 52 Z 7 aa Alarm amp Shutdown Settings By default the Koolance audio alarm will sound if any sensor reaches 55 C 131 F When the system alarm sounds the appropriate LED temperature will flash in the display and the radiator fans and pump will increase to 100 power To change this setting for an individual sensor choose the desired channel with SET and press and hold V A together for 3 seconds The alarm temperature will begin flashing You may change this value from 0 C 32 F up to 99 C 210 F The normal temperature reading will resume if you do not press any buttons for 4 seconds System Features
10. e faulty or electrically bypassed If the sensor is listed with an S S status the cooling system alarm will sound The sensor should be replaced Please visit our support web page This page is intentionally left blank apm amre User Manual 21 Limited Warranty Koolance Incorporated Koolance warrants each new Koolance liquid cooled system the system against defects in materials or workmanship for a period of one year from the date of purchase and agrees to repair or replace any defective Koolance system without charge Shipping costs are non refundable This warranty is non transferable All warranty claims must be accompanied by the original proof of purchase THIS WARRANTY DOES NOT COVER DAMAGE RESULTING FROM ACCIDENT MISUSE OR ABUSE LACK OF REASONABLE CARE SHIPPING DAMAGE MODIFICATIONS THE AFFIXING OF ANY ATTACHMENT NOT PROVIDED WITH THE PRODUCT LOSS OF PARTS OR OPERATING COMPONENTS AT SPEEDS OR FUNCTIONS OTHER THAN THOSE SPECIFIED BY THEIR MANUFACTURERS Use of unauthorized replacement parts or liquids will void this warranty Koolance Incorporated will not pay for warranty service performed by a non authorized repair or diagnostic service and will not reimburse the consumer for damage resulting from warranty service performed by a non authorized repair service No responsibility is assumed for any special incidental or consequential damages due to a defective Koolance product In order to obtain w
11. el along the nozzle will free it When a hose has been removed it may be distorted This last portion about 1cm 7 16 should be trimmed to ensure a perfect fit with the next connection The tip should always be re cut if you needed to remove the tubing with an incision Hose Lengths appropriate lengths of tubing must be cut sei nie Before installing your liquid coolers l to connect each device For computer cooling its generally easier to estimate the required amounts with hardware already mounted On the rear of the unit the inlet and outlet locations will be labeled Generally the outlet will connect first with your CPU Cooler or the most temperature sensitive device pnamre User Manual 13 QQ With the connected outlet hose roughly estimate the length you will need to your first cooler and cut it Cut the second hose with enough length to reach the last water block that will be in your system Using the leftover tubing cut shorter pieces to link between each individual cooler 3 amp tess TTA NOTE When filling the reservoir later it will need to be pulled out from the front chassis drive bay by about 2 75 7cm Be sure to leave enough tubing between the reservoir unit and connected components to do this Continue connecting all of your coolers in the system until there are no longer any open tube ends Installation Liquid Coolers You should now install the liq
12. fluid It is possible a connection was not properly sealed however unlikely If you can see liquid somewhere on the tubing or at the bottom of the chassis computer components may need to be removed for a system test see Testing amp Filling If liquid should get onto another computer component shut down the system and remove the component In many cases the hardware will be fine after allowing it to dry However the system should not be operated until you have discovered where the leak is coming from and can repair the problem Should the leak be situated somewhere where it can not be easily repaired please contact our Technical Department for further assistance 7 My computer s BIOS gives me errors that there is no cooling fan attached Some motherboards will not boot or may generate an error or alarm if no cooling fan is attached to the CPU or motherboard chipset power connectors There is typically an option to disable this warning in BIOS but you may need to boot with a fan attached initially to disable this setting If the system is not booting due to this problem clear the CMOS and try configuring BIOS again 8 The LED Display Panel shows 5 0 or 5 5 20 5 0 S O Sensor open This indicates a temperature sensor was not found for the specified channel If there is no sensor connected to that channel this is its normal status 5 5 S S Sensor short This indicates that the sensor may b
13. ighten the fill port The cooling system should be powered on to assist in the filling process This also allows you to check hose connections and make sure there are no tubing folds leaks or blockages If cooling a computer this can be done without powering on other hardware for extra safety see below CAUTION Jumping the incorrect ATX power supply pins can cause permanent damage to the power supply Make sure the AC power cord is attached to the power supply If the power supply has a rear switch it must be set to the ON position Using the included green Jumper Wire insert the metal prongs into the fourth and sixth holes on the 20 24 pin ATX motherboard power supply plug as labeled below usually green and a black ground wire See diagram l EPS 24pin If your pump has a speed control option set it to the lowest level during v this time Allow the pump to run until the liquid noise subsides During this process cooling systems often need to be tilted gently to allow air to escape from the pump and radiator Until the pump is burped in this manner it can cavitate and there will be no circulation This does NOT indicate a problem with the pump The reservoir level will decrease during this procedure Remove the fill port cap and add more liquid when needed If you frequently hear this rushing noise in the future it usually indicates the need for more coolant That s it Replace the ATX motherboard connect
14. ion and boot up the computer Mpoasece User Manual 17 Adding Coolers amp Maintenance With normal use Koolance s liquid coolant should be replaced every 2 3 years If it ever becomes contaminated unclear or significantly changes color it should be replaced immediately A Koolance drain valve sold separately is recommended to make that process easier If you are upgrading or removing a cooling block in your system please follow the instructions below CAUTION Any time a hose is disconnected with coolant still inside leaking will occur It is highly recommended to empty your cooling system of coolant before disconnecting any hoses Working on a liquid cooling system is much easier and safer when liquid coolant is removed beforehand However certain procedures can be done without removing the coolant A binder clamp available at office supply stores is helpful for keeping a hose folded while removing or adding coolers Even so pressure within the cooling system is such that liquid will not easily flow out unless relieved elsewhere for example by opening the reservoir fill port Bend the hose directly before and after the section to be worked on Place a binder clamp on both bends or tie them in this position to help avoid fluid loss There will be some liquid exposed do not operate on the cooling system in this manner near or above electronic hardware Radiator Performance Over time dust will accumulate o
15. m water can make installation much easier Tighten the connection by sliding the compression fitting down over the nozzle and screwing securely For hose barbs use pliers to move it into the proper position 10 Installation Cooler amp Tubing Configuration There are a vast number of methods for configuring a liquid cooling system serial parallel combinations alternating components etc There is no single correct way As long as coolant is flowing and you are satisfied with your device temperatures it s an acceptable configuration Similarly the maximum number of water blocks allowed in a system will depend upon your own configuration and thermal requirements It s common to see five or more coolers in a Koolance system but the limit is at wnat temperature you are comfortable with Serial Loops A basic serial loop is recommended for almost every situation Provided your cooling system has a radiator of sufficient size for your total heat load expect only a minor difference between outlet and inlet temperatures In computer cooling a delta of less than 1 to 3 C 1 8 to 5 4 F is typical for the heat exchanger This means for most loops you don t need to worry about hot water moving from one block to the next It gets only a little warmer throughout the entire loop Generally series is the simplest and most effective configuration Each device is daisy chained to the next usually starting with
16. n the radiator While the cooling system may continue to operate in this condition performance can decrease To keep the system clean check the radiator periodically through the top fan grill and use a can of electronics air cleaner if necessary Troubleshooting We hope your Koolance system will provide you with years of reliable cooling performance To help avoid unnecessary RMA issues we have prepared this list of possible operational problems and their most common solutions 1 The pump does not appear to be operating properly Pumps need to be burped during the initial bleeding process to avoid this situation Reduce pump speed but not low enough to stop the pump While the pump is running gently tilt the system in various directions until coolant begins moving Open the fill port to relieve excess air 2 My temperatures seem too high Verify that the liquid coolers are making sufficient contact with each component Ensure thermal paste has been applied but not excessively that the block s protective bottom film has been removed and that the water block is positioned correctly see the cooler s manual Also check there are no blocks twists or crimps in the tubing Finally a dusty Radiator can result in higher temperatures Please see Draining and Maintenance for more information 3 When adjust the temperature alarm settings it skips number increments This is normal operation if your LED is se
17. ntrol airplane control air traffic control mass transport operation control life support or weapon launching control If these products are used in such hazardous environments Koolance Incorporated does not warrant them TRADEMARKS The Koolance name and logo are trademarks or registered trademarks of Koolance Inc Other company and product names used in this publication are for identification purposes only and may be trademarks or registered trademarks of their respective companies COPYRIGHT All rights reserved Copyright C Koolance Incorporated A WARNING The Koolance liquid amp coolant pack contain chemicals which may be harmful or fatal if swallowed KEEP THIS AND ALL DANGEROUS CHEMICALS OUT OF THE REACH OF CHILDREN If ingestion has occurred seek medical attention immediately Give two glasses of water Do not induce vomiting In the case of eye contact flush eyes immediately with water for 15 minutes Remove contact lenses Call a physician if irritation persists Some individuals may have an allergic skin reaction with the solution although generally mild Avoid contact as much as possible and wash exposed area with soap and water for at least 15 minutes If irritation persists or if contact has been prolonged get medical help For further information please visit our website at www koolance com CAUTION Installation of third party cooling products is done at the user s own risk Koolance Inc assumes no respon
18. sibility for damage or loss due to the installation or use of this product Additionally adding liquid coolers and other components to computer hardware may void the hardware manufacturer s original warranty If you have any specific questions on warranty coverage please contact your component or computer manufacturer If there is any point of installation that you do not understand please contact our Technical Support Staff at tech koolance com or visit our website at www koolance com support KOOLANCE CONTACT INFORMATION Koolance Incorporated USA Address Telephone Fax Sales Ema 2840 W Valley Hwy N Auburn WA USA 98001 01 253 893 7551 01 253 893 7573 il sales koolance com Tech Email tech koolance com Table of Contents System Features UAE DIAO A sasinen arinei priania EIS OA Paneles sisne iai a leaden RAE E a Ea Installation Positioning the A MN eee ee nttieemecrccete intone see tcinaseceg inneieeiaetabe lt ddeneae Reservoir amp PUMP CONNECTIONS ccccceccceeeeeeeeeeeeeeeseeeesees Fan OFS CO ea tecots os See eenhecesecenme dace aceadtesicenuastaivecanttestceeensae Power CONnNeCtiONn cccccesecceeseccceesecceeeecseseecsegeessegeessseeenes ATX Pass Through Lead ccccssccceeeseseceseeeeseceeseeesaeeeseeens Temperature Sensor Placement cccceececeeeeseeeeseeeesseeeees PONS Syne et ieee ete he ment dayne ene acne Cooler amp Tubing Configuration
19. t to display in Fahrenheit because the temperature program is based on units Celsius Some C values convert to decimal temperatures in F or skip over them and these can not be set by the program 4 After the system has been on for awhile the temperature alarm sounds Make sure the LED temperature is at or above your preset alarm temperature default is 55 C 131 F If not the audio alarm may be emanating from another location such as your motherboard s BIOS alarm or video card The Koolance LED temperature will flash whenever the cooling system alarm sounds If the alarm is produced by the Koolance unit and the LED temperature has not reached the alarm preset please contact our technical department Also verify that the pump is operating see Troubleshooting 1 and that liquid movement is present in the reservoir If the reservoir has been over filled apm amre User Manual 19 this procedure may not be possible since there will be no visible air gap 5 My system has boot up problems or does not turn on Make sure the AT X wire lead is connected to NO Normally Open on the rear of the unit See Reservoir and Pump Connections for details If this does not solve the issue it is unrelated to the Koolance unit In a computer a problem with the RAM motherboard power supply video card processor or monitor can cause the system to appear not to boot up properly 6 My system appears to be leaking
20. uid coolers CPU GPU Hard Drive etc to your hardware before continuing this User Manual Please refer to your cooler kit s individual installation instructions then continue on to the next section Chapter Filling amp Maintenance period of time Never power on the computer or cooling system without sufficient liquid in the reservoir Dry running and thereby damaging the pump is not covered under the Koolance product warranty WARNING The cooling system s pump can not be run dry for any ppa User Manual 15 Testing amp Filling ces Once all the water blocks have been connected the system can be filled with coolant The fill port is located on top of the reservoir Free this component by removing its side drive screws Slowly pull it out just enough to expose the refill plug about 2 75 7cm when filling the system and keep all liquids away from electronics and power cables In case of emergency during installation immediately unplug the primary AC power cable Dry the system thoroughly before proceeding WARNING Most coolants are electrically conductive Use caution Slowly fill the system To maintain the product warranty use only Koolance approved coolant Many alternative liquids and additives can cause permanent damage to the cooling unit through chemical reaction corrosion biological growth thermal expansion viscosity etc e Replace the fill port on the reservoir Do not overt