USER MANUAL MODEL 552 Series High Speed Telco Surge
Contents
1.
2. Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technical Service at 301 975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepted Patton Electronics technical staff is also available to answer any questions about the installation or use of your Model 552 Technical Service hours are 8AM to 5PM EST Monday through Friday 1 2 CE NOTICE The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility EMC directive and the Low Voltage Directive LVD of the Union European EU A Certificate of Compliance is available by contacting Technical Support 1 3 FCC COMPLIANCE The 552 Series of surge protectors have been tested and found to comply with FCC Parts 15 and 68 A label on the device bears the Part 68 registration number 1 This equipment complies with Part 68 of the Federal Communications Commission Rules On the outside surface of this equipment is a label that contains among other information the FCC registration number This information must be provided to the telephone company 2 If this equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice is not practical the telephone company will notify the custom
3. 1 975 1007 2 1 FEATURES Uses a multi stage hybrid circuit for the best possible protection Handles surge energy up to 1 5 kW Conforms to the UL497A telco specification except E1 versions Available for ISDN U 8 wire ISDN ST 4 wire T1 E1 ISDN PRI DDS leased line and dial up configurations Diverts surges directly to chassis ground through braided metal ground strap Equipped with two RJ 45 jacks or four BNC connectors Easy to install Made in the U S A 2 2 DESCRIPTION The potential threats to ISDN and Telco hardware are vast lightning AC power induction electrostatic discharge ground potential differences EMI RFI interference and more The Patton Model 552 has been designed to greatly reduce these risks Just attach one unit to each of your telco ports and rest easy The Model 552 connects directly between twisted pair telco cables and their respective I O ports Grounding is accomplished using an external ground strap that provides a separate unit ground to chassis ground connection By shunting threatening voltages directly to chassis ground the Model 552 insures data integrity and protects connected equipment from damage The Model 552 uses a solid state design and sophisticated multistage hybrid circuits to achieve maximum protection without performance loss Eight versions are available Model 552 ST 552 D8 and 552 L8 protect all 8 pins Model 552 D6 protects six pins Models 552 DDS 552 D4 552 U 552 L4
4. 552 E1 552 E1 CX and 552 T1 protect four pins and Model 552 D2 protects two pins All versions provide up to 1500 Watts of data line protection NOTE Model 552 L8 may be used to protect Leased Line DDS T1 E1 ISDN PRI and ISDN BRI U and ST interfaces WARNING This product will not provide complete protection should your equipment or building be subject to a direct lightning hit 4 3 0 INSTALLATION Patton s Model 552 is easy to install and should give you years of trouble free service Here are a few simple instructions to help you get things hooked up right 1 2 ze TX and RX from Unplug disconnect the existing connection between the network cable and the equipment s I O port Install the Model 552 between the incoming network cable and the protected equipment using the 6 inch 15 2cm modular patch cable supplied Place the surge protector as close as possible to the device being protected NOTE To ensure proper operation of the Model 552 make sure that your equipment is connected to the protected side of the Model 552 See Figure 1 below NOTE The Model 552 E1 CX has two pairs of BNC jacks that connect one to one through the device See Figure 2 below Connect the braided ground strap directly to a chassis ground connection on the protected device If you are not sure where to locate a chassis ground connection on your equipment consult the equipment s user manual or contact the manufac
5. USER MANUAL MODEL 552 Series High Speed Telco Surge Protectors MODEL 552 ISDN ST intertace Surge Protect SN 123456789 PE PATTON Ms ElecironicsTo ISO Part 07M552 E SALES OFFICE ar 301 975 1000 Al Revised 06 24 09 TECHNICAL SUPPORT 301 975 1007 An 150 9001 http www patton com Certified Company p p 1 0 WARRANTY INFORMATION Patton Electronics warrants all Model 552 components to be free from defects and will at our option repair or replace the product should it fail within one year from the first date of shipment This warranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modification If this product fails or does not perform as warranted your sole recourse shall be repair or replacement as described above Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product These damages include but are not limited to the following lost profits lost savings and incidental or consequential damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materials
6. ec 1500 Watts for 1 msec 400A with an 8 20 usec pulse Common Mode Center Pins and Shield to shielding braids Center Pins to Shields Pins Protected Clamping Voltage Surge Capacity Protection Mode Differential Mode Pins Protected Clamping Voltage Surge Capacity Protection Mode Differential Mode Model 552 L4 and 552 U Pins 3 4 5 6 62 Volts in 500 nsec 1500 Watts for 1 msec 400A with an 8 20 psec pulse Common Mode pins 3 4 5 6 to shielding braid Pins 3 4 5 and 6 Model 552 L8 and 552 ST Pins 1 2 3 4 5 6 7 8 62 Volts in 500 nsec 1500 Watts for 1 msec 400 A with an 8 20 usec pulse Common Mode pins 1 2 3 4 5 6 7 8 to shielding braid Pins 1 2 3 4 5 6 7 8 NOTE In addition to protecting leased line modem interfaces the Model 552 L8 may also be used to protect DDS T1 E1 ISDN PRI and ISDN BRI U and ST interfaces Pins Protected Clamping Voltage Surge Capacity Protection Mode Differential Mode Model 555 GS2 and 552 GS4 552 GS2 Pins 4 5 552 GS4 Pins 3 4 5 6 18 Volts in 500 nsec 600 Watts for 1 msec 400A with an 8 20 usec pulse Common Mode Pins 4 5 GS2 Pins 3 4 5 6 GS4 to shielding braid Pins 4 5 GS2 Pins 3 4 5 6 GS4 Copyright O 1997 2001 2009 Patton Electronics Company All Rights Reserved Notes Notes
7. er as soon as possible Also you will be advised of your right to file a compliant with the FCC if you believe it is necessary 3 The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications in order to maintain uninterrupted service 4 If trouble is experienced with any of the Model 552 Series please contact Patton Electronics Company at 301 975 1000 If the equipment is causing harm to the network the telephone company may request you to remove the equipment from the network until the problem is resolved 5 Repairs are to be made only by Patton Electronics Company or its licenses Unauthorized repairs void registration and warranty 6 This equipment cannot be used on public coin service provided by the telephone company Connection to Party Line Service is subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information 1 4 INDUSTRY CANADA NOTICE NOTICE The Industry Canada label identifies certified equipment This certification means that the equipment meets telecommunications network protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document s The Department does not guarantee the eq
8. for 1 msec 250A with an 8 20 usec pulse Common Mode Pins 4 5 to shielding braid Pins 4 5 Model 552 D4 Pins 3 4 5 6 on the RJ 45 Interface Pins 2 3 4 5 on the RJ 11 Interface 310 Volts in 500 nsec 1500 Watts for 1 msec 250A with an 8 20 psec pulse Common Mode Pins 3 4 5 6 to shielding braid Pins 3 4 5 6 Pins Protected Clamping Voltage Surge Capacity Protection Mode Differential Mode Pins Protected Clamping Voltage Surge Capacity Protection Mode Differential Mode Pins Protected Clamping Voltage Surge Capacity Protection Mode Differential Mode Pins Protected Clamping Voltage Surge Capacity Protection Mode Differential Mode Model 552 D6 Pins 2 3 4 5 6 7 on the RJ 45 Interface Pins 1 2 3 4 5 6 on the RJ 11 Interface 310 Volts in 500 nsec 1500 Watts for 1 msec 250A with an 8 20 usec pulse Common Mode Pins 2 3 4 5 6 7 to shielding braid Pins 2 3 4 5 6 7 Model 552 D8 Pins 1 2 3 4 5 6 7 8 310 Volts in 500 nsec 1500 Watts for 1 msec 250A with an 8 20 psec pulse Common Mode Pins 1 2 3 4 5 6 7 8 to shielding braid Pins 1 2 3 4 5 6 7 8 Model 552 T1 and 552 E1 Pins 1 2 4 5 62 Volts in 500 nsec 1500 Watts for 1 msec 400A with an 8 20 psec pulse Common Mode Pins 1 2 4 5 to shielding braid Pins 1 2 4 5 Model 552 E1 CX All shields and center pins 62 Volts in 500 ns
9. turer Correct ground connection is critical for proper operation of the Model 552 Connection to frame ground Input from ee eee Output to protected network equipment eee UNPROTECTED d3193104d TX and RX to network a feeb eee Hm protected 4 e equipment Bu SE R E ee Figure 2 Model 552 E1CX One to One Connection 5 Series Resistance In Line Fuse Rating Approvals Connectors Pins Protected Clamping Voltage Surge Capacity Protection Mode Differential Mode Pins Protected Clamping Voltage Surge Capacity Protection Mode Differential Mode Pins Protected Clamping Voltage Surge Capacity Protection Mode Differential Mode APPENDIX A MODEL 552 SPECIFICATIONS General 0 340 Ohms 250V 3 4A 2 95 A sec Nominal Melting Point UL497A Telco Specification except E1 versions CE EMC Directive EN 50082 1 Two female RJ 45 or 4 BNC jacks Model 552 DDS Pins 1 2 7 8 62 Volts in 500 nsec 1500 Watts for 1 msec 400A with an 8 20 usec pulse Common Mode Pins 1 2 7 8 to shielding braid Pins 1 2 7 8 Model 552 D2 Pins 4 5 on the RJ 45 Interface Pins 3 4 on the RJ 11 Interface 310 Volts in 500 nsec 1500 Watts
10. uipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations 2 Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate 2 0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product This product has been thoroughly inspected and tested and is warranted for One Year parts and labor If you have any questions while installing or using this product please do not hesitate to contact Patton Electronics Technical Support at 30