Home

Superplex User Manual draft

image

Contents

1. Superplex s User s Manual Draft CONTENTS 1 Getting to know your Superplex Package Listin a a e Basic PECHINA dd da APPLE Ct A A eee AAA a E 2 Setting Up Your Superplex gt Power OO OM ica tdaids e Battery Charging tn A A ais e Interface Port Connection to External DeViC S cescscsssessceseeteeseeeescescescseceeceeeeseeseesaeeaes 3 Exploring Quick Button Access Functions e O Md iaa View Events HiStO Vii Aedes fest ZOMG SEMSOMS ii a A A dadas e Panel Armand Disarm ineaca EAN EONA E aS AEAEE RAAKAA SE TES 4 Exploring Menu Functions e Device Memory Delete aci a Events History Memory Delete ninani di e Zone Sensor Bypassing arene a a A dia e New Remote Controller Enrolling ccccsssssssssecssssecsecsscsecssceesesaesaesesscessescaeceesseseessseseeees e Enrolled Remote Controller ROMOVING cccccsccscssssscesssscessesseseessesseecassaeceeseeseessseeeassasenees e New Zone Sensor En rOlling cccssccccsessecsscsscsecsscesesssesasssesescaesescassecseseesesesaaesassaesaesanseeseaeses e Enrolled Zone Passive REMOVING c cccssssesssesssseessecescseseecessescessesaesaeecessessaeseesasseeseesesaesasens Date Tim ConfigurationS ci alterna daha ne dea kasi Mines oD Thank you for purchasing this device SUPERPLEX High Performance simplified home security controller 1 Getting to Know Your Superplex Package List Ensure the below list of items is packed
2. WN button Decrement the selected parameter value SELECT button Accept the set parameter value and advance to the next CANCEL BACK button Abort and return to previous menu page Follow the above instructions to set the next parameter and press SELECT button to save and exit setup To setup date navigate to the menu page as below IDLE MENU gt MAIN gt Settings gt Date Time Set gt Set Date Date in DD MM YY configuration will be displayed The settable date parameter is indicated by a continuous digit flash The user buttons are used to set these parameters UP button Increment the selected parameter value DOWN button Decrement the selected parameter value SELECT button Accept the set parameter value and advance to the next CANCEL BACK button Abort and return to previous menu page Follow the above instructions to set the next parameters When the last parameter value has been set press SELECT button to save and exit setup
3. e See below the process to enrol new sensors IDLE MENU gt MAIN gt Settings gt Program Sensors At this point the SENSORS menu page is displayed to allow user to select a zone to enrol a new zone sensor Zones are entities in Superplex s memory to hold an enrolled zone sensor s information UP button Scroll up the zone selection DOWN button Scroll down the zone selection SELECT button Select the pointed zone and advance to next menu page see below CANCEL BACK button Abort and return to previous menu page Upon zone selection of user s choice the menu will advance to the next page as below IDLE MENU gt MAIN gt Settings gt Program Sensors gt Zone n This level of the menu will display zone s information its status and options to either delete or load new zone sensor If the zone is available for storing new a zone sensor the status message gt EMPTY lt is displayed and If the zone has stored contents the name of the stored zone sensor is displayed rather UP button Scroll up the menu options DOWN button Scroll down the menu options SELECT button Select the pointed option and advance to next menu page see below CANCEL BACK button Abort and return to previous menu page If the zone is not in use select the Load New option to advance to the next menu page as below or else follow the instructions in Enrolled Zone Sens
4. hould indicate charging in progress by horizontal lines across the icon When charging is complete the battery level icon will display one solid bar Thus four battery level status bars Tip Always allow full charging of the battery to maximise system s active time and battery lifespan Interface Port Connection to External Devices The Superplex is equipped with five outputs to interface to external devices All five outputs are open collectors designed to sink 500mA max and rated to function with up to 13 8V See below diagram Port Number Port Type Configuration Function 1 Output Open Collector Siren 2 Output Open Collector Alarm 3 Output Open Collector Panic 4 Output Open Collector Tamper Trouble 5 Output Open Collector Status 6 Common Ground Common GND Siren Output Interface to siren control input of an external device Its signals are as below e Superplex arming 1 x pulse e Superplex disarming 2 x pulses e Superplex disarming while alarm had triggered 3 x pulses e Detected Alarm Tamper Panic Latch for 15sec or until alarm is silenced by user Alarm Output Connect to external device to trigger when alarm detected Signals are shown below e Alarm detection Latch for 15sec or until alarm is silenced by user Panic Output Interface to external device to trigger when Panic alarm is detected Signals described below e Panic alarm detection latch for 15sec or unt
5. il alarm is silenced by user Tamper Trouble output Connect to external device to trigger when zone sensors are being tampered with or when their health status is faulted Signals are described below e Tamper alarm detection Latch for 15sec or until alarm is silenced by user e Trouble signal detection Latch for 15sec or until alarm is silenced by user Status Output This port alerts the external device interfaced to it of the Superplex s armed or disarmed status Signals a described below e Superplex armed Output is latched high e Superplex disarmed Output is latched low e Superplex armed and has received alarm Output pulsing until system disarm GND Ground Connection Connect to the external device s ground for a return path Tip Care must be taken to limit the sink current of outputs Minimal current sinking is advised to yield minimised thermal intensification 3 Exploring Quick Button Access Functions The Superplex s user s buttons are designed to have more than one function command thus a user can access multiple options depending on which level of the menu tree they re viewing Quick Button Access functions are only accessible on system s idle menu and are described below together with their alternating functions Note Ensure your Superplex is in idle menu display prior to practicing the below instructions Open Menu The SELECT Quick Menu Entry button is used to enter the Superp
6. in your Superplex packaging box 1 Oh oP 0 oS 1 x Superplex Security Controller unit 2 x Qtron Robo remote controllers 1 x AC DC wall charger 1 x Superplex User s Manual Booklet 1 x Interface Port I O Loom Basic Specifications e Size 105mm L x 65mm W x 21mm H e Weight 146g e Max Standby time ap prox 72 hours e Max RF link range insight 250 meters e Display 128 x 64 pixel graphical Blue backlight e Interface Port 5 x Open Collector Outputs and 1 x Common Ground 500mA max sink current 13 8V max Voltage Appearance Superplex Security Controller Outline sketch 20 907 990100 JE UP Quick Entry Zone Test Down Quick Entry Arm Disarm Select Quick Entry Main Menu entry Cancel or Back Quick Entry Events History view Antenna Display Charge Port Interface Port 2 Setting up Your Superplex Power On Off Power on Press any of the four buttons Power Off Press CANCE BACK button and hold The power down countdown timer will be visible on the display and the system will shut down when it times out Tip Power down can be aborted by pressing the SELECT button while countdown timer active Battery Charging Plug the supplied AC DC wall charger to AC mains and insert the charger s pin into the Superplex s charging port System charging graphical message is displayed Observe the battery level icon on display it s
7. lex s Main Menu when in idle menu level The Main Menu is the initial page of the menu tree to allow user to access features of the Superplex Press SELECT Quick Menu Entry button to enter Main Menu IDLE MENU gt Main Menu gt Settings Arm Disarm System Bypass Options VVV V Memory Management View Events History The Superplex is capable of logging real time events into its event history memory These events are accessible to the user using the Quick Events Entry button One event s information is displayed at the time and scrolling up or down leads to viewing a previous or next event respectively Event view wrapping is possible after viewing the last or first event Press CANCEL or BACK Quick Events Entry button to enter Events View IDLE MENU gt History gt gt Event number Event Date Event Time Event Type Originator s Name Test Zone Sensors To test if enrolled zone sensors are discoverable by the Superplex a zone test can be performed Enter the zone test menu and walk pass the enrolled sensor to trigger intrusion alarm NOT TAMPER If enrolled sensor is functional and discoverable its designated zone number and origin name will be displayed as detected Press UP Quick Zone Test Entry button to enter Zone Test page IDLE MENU gt Zone Test gt gt Searching Or Detected Zone number Originator s Name To exit and
8. lots are entities in Superplex s memory to hold an enrolled remote controller s information UP button Scroll up the slot selection DOWN button Scroll down the slot selection SELECT button Select the pointed slot and advance to next menu page see below CANCEL BACK button Abort and return to previous menu page Upon Slot selection of user s choice the menu will advance to the next page as below IDLE MENU gt MAIN gt Settings gt Program Remotes gt Slot n This level of the menu will display Slot s information its status and options to either delete Slot or load new remote controller If the Slot is available for storing new remote controller the status message gt EMPTY lt is displayed and If the Slot has stored contents the name of the stored remote controller is displayed rather UP button Scroll up the menu options DOWN button Scroll down the menu options SELECT button Select the pointed option and advance to next menu page see below CANCEL BACK button Abort and return to previous menu page If Slot is not in use select the Load New option to advance to the next menu page as below or else follow the instructions in Enrolled Remote Controller Removing to clear Slot IDLE MENU gt MAIN gt Settings gt Program Remotes gt Slot n gt Load New A Press gt OK lt to Start prompt message is displayed to allow user time for
9. n the selected slot 7 To abort process at remote naming stage press and hold CANCEL BACK button until cancel message is displayed Enrolled Remote Controller Removing Enrolled user s remote controllers are contained in Slots and can be deleted or removed individually thus clearing the Slot IDLE MENU gt MAIN gt Settings gt Program Remotes gt Slot n This level of the menu will display Slot s information its status and options to either delete Slot or load new remote controller If the Slot is available for storing new remote controller the status message gt EMPTY lt is displayed and If the Slot has stored contents the name of the stored remote controller is displayed rather UP button Scroll up the menu options DOWN button Scroll down the menu options SELECT button Select the pointed option and advance to next menu page see below CANCEL BACK button Abort and return to previous menu page If the Slot contains the desired remote controller to delete select the Erase option to advance to the next menu page as below IDLE MENU gt MAIN gt Settings gt Program Remotes gt Slot n gt Erase A prompt message will be displayed in order to ascertain remote controller delete operation Follow the displayed instructions New Zone Sensor Enrolling Up to 32 zone sensors can be enrolled by the Superplex Each zone sensor can be allocated a user defined nam
10. or Removing to clear zone IDLE MENU gt MAIN gt Settings gt Program Sensors gt Zone n gt Load New A Press gt OK lt to Start prompt message is displayed to allow user time for preparation of enrolment process Follow the instruction steps as displayed and note that the process can be aborted by pressing the CANCEL BACK button Press SELECT button to initialize process Display Awaiting Tamper Code Trigger a tamper alarm on the sensor to be enrolled The system will advance to the next step Note Superplex will only advance to the next step if it has received a valid Robo sensor s Tamper code only 3 Atthis stage the zone sensor naming menu page is displayed Use UP or DOWN buttons to scroll through the characters The character pointers indicate the pointed character and the selection is through the SELECT button Selected characters are displayed on text show area on display as they re chosen 4 With the zone name in place completion of the new zone sensor enrolment is done by pressing the SELECT button and holding it down until a Loading done message is displayed The new zone sensor is stored in the selected zone 5 To abort process at zone sensor naming stage press and hold CANCEL BACK button until cancel message is displayed Enrolled Zone Passive Removing Enrolled user s zone sensors are contained in zones and can be deleted or removed indi
11. preparation of enrolment process Follow the instruction steps as displayed and note that the process can be aborted by pressing the CANCEL BACK button Press SELECT button to initialize process Display Waiting for Button 1 Press the first button on remote controller to configure its function Note Superplex will only advance to the next step if it has received a valid Robo remote controller s button data 3 Select desired button function from the four displayed options Use the UP or DOWN buttons to scroll through the options and the SELECT button to accept pointed selection 4 Follow the instruction displayed Repeat process in 2 And 3 For all four buttons Note Less than four buttons can be loaded if desired This is done by pressing the SELECT button while the system prompts you to load a button 5 Upon the last button being loaded or skipped as mentioned above the system will advance to the remote naming menu page Use UP or DOWN buttons to scroll through the characters The character pointers indicate the pointed character and the selection is through the SELECT button Selected characters are displayed on text show area on display as they re chosen 6 With the remote name in place completion of the new remote controller enrolment is done by pressing the SELECT button and holding it down until a Loading done message is displayed The new remote is stored i
12. return to Idle Menu page press UP Quick Zone Test Entry or CANCEL button Panel Arm and Disarm This function enables arming and disarming from the Superplex Press DOWN Quick Arm Disarm Entry button to arm system if it s disarmed Press the same button to disarm system if armed IDLE MENU gt System Armed gt gt Superplex is armed IDLE MENU gt System Disarmed gt gt Superplex is disarmed 4 Exploring Menu Functions From the Idle Menu the Main Menu is accessed by pressing the Quick Main Menu button This leads to the menu tree as below To navigate the menu the primary functions of the buttons are instated over the alternative This means UP and DOWN buttons allows user to either scroll up or down in the menu respectively The SELECT button is therefore used to accept enter or confirm pointed option Finally the CANCEL BACK button is used to revert to previous menu page cancel or exit process IDLE MENU gt MAIN gt Settings Arm Disarm Bypass Options VVVV Memory Management Device Memory Delete This clears the entire memory of the Superplex thus all events history and enrolled devices IDLE MENU gt MAIN gt MEMORY MANAGEMENT gt Erase All Memory A prompt message will be displayed in order to ascertain memory clearing operation Follow the displayed instructions Tip The Superplex prompt messages will of
13. ten refer to CANCEL button as C and SELECT button as OK Events History Memory Delete This option will only clear all stored events and reset events counter to zero IDLE MENU gt MAIN gt MEMORY MANAGEMENT gt Erase Event History Follow prompt message to perform operation Zone Sensor Bypassing The Superplex is equipped with the zone bypassing feature All alarm signals from the bypassed zone sensors are ignored when system is armed The bypass option can be individually set or cleared for each of the 32 zones Inactive zone bypassing is prohibited IDLE MENU gt MAIN gt Bypass Options This page displays the zone number and name to be configured including ts current state UP button Scroll up to the next zone DOWN button Scroll down to the previous zone SELECT button Set displayed zone sensor s bypass or clear displayed zone sensor s bypass CANCEL BACK button Abort and return to previous menu page New Remote Controller Enrolling The Superplex is capable of enrolling up to eight Robo compatible remote controllers with up to four buttons All four buttons on remote are user configurable and each remote can be granted a user s choice name during the enrolling process IDLE MENU gt MAIN gt Settings gt Program Remotes At this point the REMOTES page is displayed to allow user to select a slot to enrol a new remote controller S
14. vidually thus clearing the zone IDLE MENU gt MAIN gt Settings gt Program Sensors gt Zone n This level of the menu will display zone s information its status and options to either delete or load new zone sensors If the zone is available for storing new zone sensors the status message gt EMPTY lt is displayed and If the zone has stored contents the name of the stored zone sensor is displayed rather UP button Scroll up the menu options DOWN button Scroll down the menu options SELECT button Select the pointed option and advance to next menu page see below CANCEL BACK button Abort and return to previous menu page If the zone contains the desired zone sensor to delete select the Erase option to advance to the next menu page as below IDLE MENU gt MAIN gt Settings gt Program Sensors gt Zone n gt Erase A prompt message will be displayed in order to ascertain zone sensor delete operation Follow the displayed instructions Date Time Configurations Date and time can be setup by user as guided below To setup time navigate to the menu page as below IDLE MENU gt MAIN gt Settings gt Date Time Set gt Set Time Time in hours and minutes will be displayed The settable time parameter is indicated by a continuous digit flash The user buttons are used to set these parameters UP button Increment the selected parameter value DO

Download Pdf Manuals

image

Related Search

Related Contents

  Manual de operação - Pivo 5000  Hampton Bay VFB25ACLED2 Instructions / Assembly  INSTALLATION MANUAL MANUEL D`INSTALLATION  EP135-ESC Troyes-2 - Studyrama Grandes Ecoles  to download. - Intrepid Astrology Software  PDFファイル - 医薬品医療機器総合機構  User Manual - designFARM  Ouvrages  HP vp6311 Quick Setup Guide  

Copyright © All rights reserved.
Failed to retrieve file