Home

InfiniiVision 3000 X-Series Oscilloscopes

image

Contents

1. F Th 3 Notice that the Agilent 3000 X Series allows you to see more of your signals and captures the infrequent glitch and jitter that you are unable to see on other oscilloscopes in this class Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget See more of your signal more of the time Deeper memory for longer time capture Agilent With up to 4 Mpts of MegaZoom V deep memory you can capture long non repeating signals while maintaining a high sample rate then quickly zoom in on areas of interest The InfiniiVision X Series optimizes your deep memory oscilloscope measurements by using MegaZoom V technology to make the most effective trade offs in sample rate memory depth and waveform update rate Although you may think deeper memory is always better using deep memory means making tradeoffs for many other scopes on the market today Scopes with deep memory are typically priced higher and require additional waveform processing time to acquire deep memory waveforms This typically means waveform update rates will be reduced sometimes significantly For this reason most other scopes have manual memory depth selections and the typical default memory depth setting is usually relatively shallow 10 to 100 kpts If you want to use deep memory in these other scopes you must manually turn it on and deal with the update rate tradeoff So you have to know when it is impo
2. front and real panel Supports memory devices and printers One USB 2 0 hi speed device port on rear panel 10 100Base T requires DSOXLAN module Connect oscilloscope display to an external monitor or projector requires DSOXLAN module To allow easy migration into existing test systems requires DSOXGPIB Square wave 2 5 Vpp 1 kHz Rear panel security slot connects to standard Kensington style lock Front Panel BNC Connector Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Performance characteristics WaveGen Built in function generator Waveforms Sine Square wave pulse Ramp triangle wave Noise Frequency Amplitude DC offset Trigger output Sine square pulse triangle ramp noise DC Frequency range 0 1 Hz to 20 MHz Amplitude flatness 0 5 dB relative to 1 kHz Harmonic distortion 40 dBc Spurious non harmonics 40 dBc Total harmonic distortion 1 SNR 50 ohm load 500 MHz BW 40 dB Vpp gt 0 1 V 30 dB Vpp lt 0 1V Frequency range 0 1 Hz to 10 MHz Duty cycle 20 to 80 Duty cycle resolution Larger of 1 or 10 ns Pulse width 20 ns minimum Rise fall time 18 ns 10 to 90 Pulse width resolution 10 ns or 5 digits whichever is larger Overshoot lt 2 Asymmetry at 50 DC 1 5 ns Jitter TIE RMS 500 ps Frequency range 0 1 Hz to 100 kHz Linearity 1 Variable symmetry 0 to 100 Symmetry resolution 1
3. 2 mV div is a magnification of 4 mV div setting For vertical accuracy calculations use full scale of 32 mV for 2 mV div sensitivity setting Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Performance characteristics Vertical system digital channels All MSO 3000 X Series models and on all DSO 3000 X Series models with after purchase upgrade Characteristics Digital input channels 16 digital DO to D15 Thresholds Threshold per set of 8 channels Threshold selections TTL 1 4 V 5 V CMOS 2 5 V ECL 1 3 V User definable selectable by pod User defined threshold range 8 0 V in 10 mV steps Maximum input voltage 40 V peak CAT transient overvoltage 800 Vpk Threshold accuracy 100 mV 3 of threshold setting Maximum input dynamic range 10 V about threshold Minimum voltage swing 500 mVpp Input impedance 100 kQ 2 at probe tip Probe loading 8 pF Vertical resolution 1 bit Horizontal system analog channels All 3000 X Series models Characteristics Maximum sample rate 2 GSa sec 4 GSa s half channel interleaved Maximum record length 2 Mpts per channel 4 Mpts half channel interleaved Maximum duration of time captured 1ms at highest sample rate all channels DSOX3012A DSOX3014A DSOX3024A DSOX3032A DSOX3034A DSOX3052A DSOX3054A MSOX38012A MS0X3014A MS0X3024A MSO0X38032A MSOX38034A MS0X3052A MSOX38004A Time base range 5ns div to 5 ns div to 2 ns div to 2 ns div to 2 ns d
4. 3 4 3 4 3x4 f t 1 2 1 2 1x2 3 4 3 4 3x4 FFT g t differentiate d dt g t integrate g t dt square root Vg t Where 1 2 3 4 represent analog input channels 1 2 3 and 4 Note Channels 3 and 4 only available on MSO DSOX3xx4A models FFT Up to 64 kpts resolution Set FFT Window to Hanning Flat Top Rectangular Blackman Harris Denotes warranted specifications all others are typical Specifications are valid after a 30 minute warm up period and 10 C from firmware calibration temperature 2 mV div is a magnification of 4 mV div setting For vertical accuracy calculations use full scale of 32 mV for 2 mV div sensitivity setting 21 Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Performance characteristics Display characteristics Characteristics Display Resolution Graticules Format Maximum waveform update rate Persistence Intensity gradation All 3000 X Series models 8 5 inch WVGA 800 H x 480 V pixel format screen area 8 vertical divisions by 10 horizontal divisions with intensity controls YT and XY gt 1 000 000 wfms s Off infinite variable persistence 100 ms 60 s 64 intensity levels Input output ports Port USB 2 0 hi speed host port USB 2 0 hi speed device port LAN port Video out port GPIB port Probe compensator output Kensington style lock WaveGen out All 3000 X Series models Two USB 2 0 hi speed host ports
5. Bandwidth 20 MHz typical Sine wave and ramp accuracy o 130 ppm frequency lt 10 kHz o gt 50 ppm frequency gt 10 kHz Square wave and pulse accuracy o gt 50 frequency 200 ppm frequency lt 25 kHz 50 ppm frequency 25 kHz Resolution 0 1 Hz or 4 digits whichever is larger Range o 20 mVpp to 5 Vpp into Hi Z o 10 mVpp to 2 5 Vpp into 50 ohms Resolution 100 uV or 3 digits whichever is higher Accuracy 2 frequency 1 kHz Range o 2 5 V into Hi Z o 1 25 V into 50 ohms Resolution 100 uV or 3 digits whichever is higher Accuracy 1 5 of offset setting 1 5 of amplitude 1 mV Trigger output available on Trig out BNC 23 Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget InfiniiVision X Series physical characteristics Instrument Dimensions Width Height Depth Weight Instrument only With accessories Instrument shipping package dimensions Width Height Depth Rack mount Width Height Depth mm Inches 380 6 14 98 204 4 8 05 141 5 5 57 kg Ib 3 85 8 5 4 08 9 0 mm Inches 450 17 7 250 9 84 360 14 17 mm Inches 481 6 18 961 7715 8 72 189 34 7 454 Environmental Characteristic Temperature Humidity Altitude Electromagnetic compatibility Safety Vibration Shock Operating 0 to 55 C Nonoperating 40 to 71 C Operating Up to 80 RH at or below 40 C up to 45 RH up to 50 C Non operating Up t
6. UART e Automotive and industrial serial triggering and analysis CAN LIN e Audio serial triggering and analysis I S Agilent Agilent s InfiniiVision Series oscilloscopes are the industry s only scopes to use hardware based serial protocol decoding Other vendors scopes use software post processing techniques to decode serial packets frames With these software techniques waveform and decode update rates tend to be slow sometimes seconds per update That s especially true when using deep memory which is often required to capture multiple packetized serial bus signals And when analyzing multiple serial buses simultaneously decode update rates can be even slower Faster decoding with hardware based tech nology enhances scope usability and more importantly the probability of capturing infrequent serial communication errors After capturing a long record of serial bus com munication using the InfiniiVision scope s MegaZoom V deep memory you can easily perform a search operation based on specific criteria and then quickly navigate to bytes frames of serial data that satisfy that search criteria Sometimes it may be necessary to correlate data from one serial bus to another Agilent s InfintiVision 3000 X Series oscilloscope can decode two serial buses simultaneously using hardware based decoding Plus it is the only scope on the market that can also display the captured data in a time interleave
7. an oscilloscope is and how to perform basic measurements with the Educator s Oscilloscope Training Kit DSOXEDK It includes training tools created specifically for electrical engineering and physics undergraduate students and professors It contains an array of built in training signals a comprehensive oscil loscope lab guide and tutorial written specifically for the undergraduate student and an oscilloscope fundamentals PowerPoint slide set for professors and lab assistants For more information refer to www agilent com find EDK Also available are DreamCatcher s full semester applica tion specific courseware written around Agilent test and measurement equipment www dreamcatcher asia cw Get your students to quickly put the scope to work Intuitive localized front panel design with pushable knobs for quick access to commonly used oscilloscope functions help students spend more time learning the concepts and less time learning how to use the oscilloscope Enable your students to answer their own questions with the localized built in help system that provides quick access by simply pressing and holding any button DSOXEDK Educator s Oscilloscope Training Kit Stretch your budget over the long term Save money with an industry exclusive built in 20 MHz WaveGen instead of buying a separate function generator 2 7 Buy what you need today and protect your investment in d yen the future with the only oscilloscopes in this cla
8. connectivity if you need it as well as the ability to connect to an external monitor An optional GPIB module is also available Only one module may be used at a time Keep accessories with the scope A built in storage compartment allows you to easily keep your probes power cords and other accessories with the oscilloscope Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Designed with research and development in mind Find more glitches and infrequent events quickly Debugging and fixing designs is one of the most important tasks of R amp D engineers so that they can ship reliable prod ucts to their customers Finding the infrequent and random circuit problem is often like looking for a needle in a hay stack In addition to fast waveform updates which improve a scope s probability of capturing infrequent anomalies it is often necessary to search waveform records and or trigger on specific pulse parametric violation conditions Agilent s InfinitVision 3000 X Series oscilloscope provide the most comprehensive set of Search amp Navigation capabilities as well as the most advanced set of pulse parameter triggering selections of any oscilloscope in its class Search and Navigation ma When capturing long complex waveforms using the scopes deep acquisition memory manually scrolling through stored waveform data to find specific events of interest can be slow and cumbersome But with t
9. from composite video or broadcast standards NTSC PAL SECAM PAM M Trigger on start of packet end of packet reset complete enter suspend or exit suspend Support USB low speed and full speed Trigger on 2 s complement data of audio left channel or right channel 4 lt gt gt lt lt gt increasing value or decreasing value Trigger on IC Inter IC bus serial protocol at a start stop condition or user defined frame with address and or data values Also trigger on missing acknowledge address with no accq restart EEPROM read and 10 bit write Trigger on SPI Serial Protocol Interface data pattern during a specific framing period Supports positive and negative Chip Select framing as well as clock Idle framing and user specified number of bits per frame Trigger on CAN controller area network version 2 0A and 2 0B signals Trigger on the start of frame SOF bit standard Remote frame ID RTR data frame ID RTR remote or data frame ID data frame ID and data error frame all errors acknowledge error and overload frame Trigger on LIN Local Interconnect Network sync break sync frame ID or frame ID and data Trigger on Rx or Tx start bit stop bit or data content 20 Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Performance characteristics Acquisition modes All 3000 X Series models Characteristics Normal Peak detect Capture glitches as narrow a
10. resolution A ee wide screen display FF 02 mm reveals subtle details i that most scopes of TT of ITY of ee ee Sener eeeninaeS S don t show you pa CT x i i i j se i UN gt j en A Tja AN gy MOS UZ MISO LIV 1 3 CS H n an oh ET 1 Lister Menu WaveGen uN l Built in USB port Industry first aa ae en makes it easy to M Ers integrated digital channels save your work and generator update your system software quickly Autoscale lets you Search and Navigat I ch and Navigate quickly display any front panel controls Quickly pan and a analog or digital make it easy to find zoom for analysis e Aa and view specific with MegaZoom V s jij 9 ma os automatically signal activity quickly instant response and play stop rewind and pee optimum resolution g Sering the vertical 1 MESA oom Rt horizontal and trigger fast forward through none D F M o a waveforms mers a or the best display while optimizing memory Agilent amp Acquisition Dedicated 4 GSa s een a keys for Lf rks quick access to serial digital Quick summary channels display of math sample rate functions channel and settings and reference measurements waMetorms All front panel knobs are pushable Push to Push to Zero Demo and training signals Oscilloscopes redefined Breakthrough technolog
11. InfintiVision 3000 X Series e Oscilloscopes x ro gt o o c 0 ee Data Sheet ad Ti k E A ia L Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Agg Agilent Technologies Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Breakthrough technology for budget conscious customers Agilent Technologies is the fastest growing scope vendor your existing budgets Whether you are looking for a basic in the market for good reason we deploy our investments entry level oscilloscope or a more sophisticated model to in technology to solve your measurement problems get your job done you want the most you can get for your This commitment to superior technology brings you the money The full line of InfiniiVision X Series oscilloscopes InfiniiVision X Series oscilloscopes engineered to deliver 26 models ensure that you get exactly what you need value functionality and flexibility at prices that fit into today with room to grow in the future Overview of the Agilent InfiniiVision X Series oscilloscopes InfiniiVision 2000 X Series InfiniiVision 3000 X Series Analog channels 2 and 4 analog channels Bandwidth upgradable 70 100 200 MHz 100 200 350 500 MHz Sample rate 1 GSa s per channel 2 GSa s per channel 2 GSa s half channel interleaved mode 4 GSa s half channel interleaved mode Memory depth 100 kpts 2 Mpts standard 4 Mpts op
12. annel whose time duration is less than a value greater than a value or inside a time range e Minimum duration setting 2 ns 10 ns depends on bandwidth e Maximum duration setting 10 s Trigger on a position runt pulse that fails to exceed a high level threshold Trigger on a negative runt pulse that fails to exceed a low level threshold Trigger on either polarity runt pulse based on two threshold settings Runt triggering can also be time qualified lt or gt with a minimum time setting of 4 ns and maximum timesetting of 10 s Trigger and clock data setup and or hold time violation from lt 0 0 to 10 s Trigger on rise time or fall time edge speed violations lt or gt based on user selectable threshold Time settings range from lt or gt or 2 ns to 10 s Trigger on the N edge of a burst that occurs after a specified idle time Trigger when a specified pattern of high low and don t care levels on any combination of analog digital or trigger channels is entered exited Pattern must have stabilized for a minimum of 2 ns to qualify as a valid trigger condition Trigger on a multi channel pattern whose time duration is less than a value greater than a value greater than a time value with a timeout or inside or outside of a set of time values e Minimum duration setting 2 ns 10 ns depends on bandwidth e Maximum duration setting 10 s Video Trigger on all lines or individual lines odd even or all fields
13. blication type Publication number Serial Bus Applications for Agilent InfiniiVision 3000 X Series Oscilloscopes Data sheet 5990 6677EN 25
14. d Lister display Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Get more investment protection with the industry s only fully upgradable oscilloscope Upgradability Project needs change but traditional oscilloscopes are fixed you get what you pay for at the time of purchase With the 3000 X Series your investment is protected If you need more bandwidth up to 500 MHz digital chan nels WaveGen or measurement applications in the future you can easily add them all after the fact Mask testing Whether performing pass fail tests to specified standards in manufacturing or testing for infrequent signal anomalies in R amp D debug the mask test option can be a valuable productivity tool The 3000 X Series features the industry s only hardware based mask testing and can perform up to 280 000 tests per second Segmented memory When capturing low duty cycle pulses or data bursts you can use segmented memory acquisition to optimize acquisition memory Segmented memory acquisition lets you selectively capture and store important segments of signals without capturing unimportant signal idle dead time Segmented memory acquisition Is ideal for applica tions including packetized serial buses pulsed laser radar bursts and high energy physics experiments Up to 1000 segments can be captured on the 3000 X Series models with a minimum re arm time under 1 us Add at the time
15. e again for scope to find another trigger event or press Run to trigger continuously in either Auto or Normal mode e Force front panel button that forces a trigger Trigger coupling DC DC coupled trigger AC AC coupled trigger cutoff frequency lt 10 Hz internal lt 50 Hz external HF Reject High frequency reject cutoff frequency 50 kHz LF Reject Low frequency reject cutoff frequency 50 kHz Noise Reject Selectable OFF or ON decreases sensitivity 2x Trigger holdoff range 40 ns to 10 00 s Trigger sentivity Internal lt 10 mV div greater of 1 div or 5 mV 10 mV div 0 6 div External 200 mVpp from DC to 100 MHz 350 mVpp 100 MHz to 200 MHz Trigger level range Any channel 6 div from center screen External 8V Denotes warranted specifications all others are typical Specifications are valid after a 30 minute warm up period and 10 C from firmware calibration temperature Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Performance characteristics Trigger type selections Characteristics Edge Pulse width Runt Setup and hold Rise fall time N edge bust Pattern Time qualified pattern Video USB I S optional I C optional SPI optional CAN optional LIN optional RS 232 422 485 UART optional All 3000 X Series models Trigger on a rising falling alternating or either edge of any source Trigger on a pulse on a selected ch
16. e 250 MHz 100 1 attenuation N2771B passive probe 50 MHz 1000 1 attenuation N2795A single ended active probe 1 GHz 8 V with AutoProbe interface N2790A differential active probe 100 MHz 1 4 kV with AutoProbe interface N2792A differential active probe 200 MHz 20 V N2793A differential active probe 800 MHz 15 V 1146A AC DC current probe 100 kHz 100A 1147A AC DC current probe 50 MHz 15 A with AutoProbe interface N2893A AC DC current probe 100 MHz 15 A with AutoProbe interface Step 4 Add the final touches 1 per channel included 100 MHz models 1 per channel included 200 MHz models 1 per channel included 350 500 MHz models 1 per scope included on all MSO models and DSOX3MSO upgrades Optional Optional Optional Optional Optional Optional Optional Optional Optional Optional 3000 X Series Recommended accessories LAN VGA connection module GPIB connection module Rack mount kit Soft carrying case and front panel cover Hard copy manual DSOXLAN DSOXGPIB N6456A N6457A N6458A Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Performance characteristics DS0X3000 Series digital signal oscilloscope MS0X3000 Series mixed signal oscilloscope DS0X3012A DS0X3014A DS0X3024A DS0X3032A DS0X3034A DS0X3052A DS0X3054A MS0X3012A MS0X3014A MS0X3024A MS0X3032A MS0X3034A MS0X3052A MSOX3004A Characteristics Analog 100 MHz bandwidth 3dB Analog input 2 channels Calcu
17. es is the first instrument in its class to offer an integrated and upgradable logic timing analyzer Digital content is everywhere in today s designs and tradi tional 2 and 4 channel oscilloscopes do not always provide enough channels for the job at hand With an additional 16 integrated digital timing channels you now have up to 20 channels of time correlated triggering acquisition and viewing on the same instrument Buy a 2 or 4 channel DSO and at anytime upgrade it yourself to an MSO with a license to turn on those integrated 16 digital timing chan nels Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Do more with the power of 4 instruments in 1 Industry exclusive WaveGen built in function generator lt gt Agilent An industry first the 3000 X Series offers an integrated 20 MHz function generator Ideal for educational or design labs where bench space and budget are at a premium the integrated function generator provides stimulus output of sine square ramp pulse DC and noise waveforms to your device under test No need to buy a separate function generator when you can get one integrated in your new oscilloscope Turn on WaveGen at any time by ordering the DSOXWaveGen option and install the license yourself Hardware based serial protocol decode and triggering e Embedded serial triggering and analysis 1 C SPI e Computer serial triggering and analysis RS232 422 485
18. he InfiniiVision 3000 X Series scope s automatic Search amp Navigation capability you can easily set up specific search criteria and then quickly navigate to found and marked events using the scope s front panel forward and back navigation keys Available search criteria include Edges Pulse Width time qualitied Rise Fall Times time quali fied Runt Pulses time and level qualified and Serial In the example shown in the screen image on the right the scope was set up to capture a 1 millisecond time span of a complex digital data stream Using the scope s Search amp Navigation capability the scope was able to find mark white triangles shows location of each runt and then quickly navigate to 20 occurrences of runt pulses Advanced Parametric and Serial Bus Triggering With today s more complex signals it is also often neces sary to trigger on complex signal conditions in order to synchronize the scope s acquisition on specific events of interest Agilent s InfiniiVision 3000 X Series scopes can trigger on the following conditions Edge Pulse Width time qualified Pattern Rise Fall Time Nth Edge Burst Runt Setup amp Hold Video USB Seriall and Serial2 y Trager SEI ip and Hold Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Designed with education in mind Quickly and easily set up or upgrade a teaching lab Teach your students what
19. iv to 1 ns div to 1 ns div to s div 50 s div 50 s div 50 s div 50 s div 50 s div 50 s div 50 s div All 3000 X Series models Time base delay time range Pre trigger Greater of 1 screen width or 200 us Post trigger 1 s to 500s Channel to channel deskew range 100 ns Time base accuracy 25 ppm 5 ppm per year aging A Time accuracy using cursors timebase acc x reading 0 0016 x screen width 100 ps Modes Main zoom roll XY XY On channels 1 and 2 only Z Blanking on Ext Trigger Input 1 4 V threshold Bandwidth Maximum bandwidth Phase error at 1 MHz lt 0 5 degree Denotes warranted specifications all others are typical Specifications are valid after a 30 minute warm up period and 10 C from firmware calibration temperature 18 Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Performance characteristics Horizontal system digital channels All MSO models and DSO models with MSO upgrade Characteristics Maximum sample rate 1 GSa s Maximum record length 2 Mpts digital only 500 kpts analog and digital channels Minimum detectable pulse width 5 ns Channel to channel skew 2 ns typical 3 ns maximum Trigger system All 3000 X Series models Characteristics Trigger modes e Normal triggered requires trigger event for scope to trigger e Auto triggers automatically in absence of trigger event e Single triggers only once on a trigger event press Singl
20. lated rise lt 3 5 ns time Hardware bandwidth limits Input coupling Input impedance Input sensitivity range Sample rate on each channel Memory depth record length Display Waveform update rate max Vertical resolution Horizontal resolution Maximum input voltage DC vertical accuracy DC gain accuracy Channel to channel isolation Offset range DC vertical offset accuracy 100 MHz 200 MHz 350 MHz 350 MHz 500 MHz 500 MHz 4 2 4 2 4 lt 3 5ns lt 1 75 ns lt 1ns lt 1ns lt 800 ps lt 800 ps All 3000 X Series models 20 MHz selectable AC DC GND Selectable 1 MQ 1 50 0 1 5 2 mV div to 5 V div 2 GSa s per channel 4 GSa s interleaved Up to 4 Mpts 8 5 inch WVGA with 64 levels of intensity grading 1 000 000 waveforms s 8 bits 2 5 ps CAT 300 Vrms 400 Vpk transient overvoltage 1 6 kVpk CAT II 300 Vrms 400 Vpk With 10073C 10 1 probe CAT 500 Vpk CAT II 400 Vpk With N2862A or N2863A 10 1 probe 300 Vrms DC vertical gain accuracy DC vertical offset accuracy 0 25 full scale 2 full scale gt 100 1 from DC to maximum specified bandwidth of each model measured with same V div and coupling on channels 2 V 2 mV div to 200 mV div 50 V gt 200 mV div to 5 V div 0 1div 2mV 1 of offset setting Denotes warranted specifications all others are typical Specifications are valid after a 30 minute warm up period and 10 C from firmware calibration temperature
21. o 95 RH up to 40 C up to 45 RH up to 50 C Operating and non operating up to 4 000 m Meets EMC Directive 2004 108 EC meets or exceeds IEC 61326 1 2005 EN 61326 1 2006 Group 1 Class A requirement CISPR 11 EN 55011 IEC 61000 4 2 EN 61000 4 2 IEC 61000 4 3 EN 61000 4 3 IEC 61000 4 4 EN 61000 4 4 IEC 61000 4 5 EN 61000 4 5 IEC 61000 4 6 EN 61000 4 6 IEC 61000 4 11 EN 61000 4 11 Canada ICES 001 2004 Australia New Zealand AS NZS UL61010 1 2nd edition CAN CSA22 2 No 61010 1 04 Meets IEC60068 2 6 and MIL PRF 28800 class 3 random Meets IEC 60068 2 27 and MIL PRF 28800 class 3 random operating 30g 2 sine 11 ms duration 3 shocks axis along major axis total of 18 shocks 24 Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget InfiniiVision X Series physical characteristics Connectivity Standard ports One USB 2 0 high speed device port on rear panel Two USB 2 0 high speed host ports front and rear panel Supports memory devices and printers Optional ports GPIB LAN VGA Nonvolatile storage Reference waveform display 2 internal waveforms or USB thumb drive Waveform storage Setup bmp png csv ASCII XY reference waveforms alb bin lister mask Max USB flash drive size Supports industry standard flash drives Set ups without USB flash drive 10 internal setups Set ups with USB flash drive Limited by size of USB drive Related literature Publication tetle Pu
22. of your purchase or upgrade later Bandwidth Digital channels MSO WaveGen Measurement applications o Serial protocol analysis o Mask testing Segmented memory o Educators lab kit gt Agilent eee iit Say ia Agilent sament 7f t Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Other productivity tools Reference waveforms gt Agilent Store up to two waveforms in the scope s non volatile reference waveform memory locations Compare these reference waveforms with live waveforms and perform post analysis and measurements on stored data You can also store waveforms on a removable USB memory device in hb format and recall them back into scope s reference waveform memory later Save and or transfer waveforms to a PC as XY data pairs in a comma separated values format csv or store bitmap images and transfer them to a PC for documentation purposes in a variety of image formats including 8 bit bitmaps bmp 24 bit bitmaps bmp and PNG 24 bit images png Localized GUI and help Operate the scope in the language most familiar to you The graphical user interface built in help system front panel overlays and user s manual are available in 11 languages Choose from English Japanese simplified Chinese traditional Chinese Korean German French Spanish Russian Portuguese and Italian During operation access the built in help system j
23. re with the power of 4 instruments in 1 oscilloscope logic timing analyzer WaveGen built in function generator optional and protocol analyzer optional Get more investment protection with the industry s only fully upgradable scope including bandwidth re ot Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget See more of your signal more of the time Largest display Fastest update rate Engineering for the best signal visibility starts with the With Agilent designed MegaZoom IV custom ASIC technol largest display Our 8 5 inch WVGA display offers 50 ogy the 3000 X Series delivers up to 1 million waveforms more viewing area with 3 4 times the resolution WVGA per second If an oscilloscope updates waveforms slowly 800x480 versus WQVGA 480x234 it can make using the oscilloscope very frustrating Fast waveform update rates can improve oscilloscope display quality to show subtle waveform details such as noise and jitter with display intensity modulation Most importantly fast waveform update rates improve the probability of capturing random and infrequent events that would not be captured using an oscilloscope with a lower waveform update rate APTF INERI Em orim jas ral arn Hiii i m f f i l E T paha a Bese e o o 5920 Qs 5 AaS He amp Qi gt 38 a a SS Snn To mm a yh oF _ a ir y oe M i
24. rtant to use deep memory and when it Is not Agilent s exclusive MegaZoom V technology automatically selects deeper memory when needed in order to maintain fast sample rates while also updating fast How does Agilent do that Agilent designed MegaZoom V custom ASIC technology combines the capabilities of an oscilloscope logic analyzer protocol analyzer and WaveGen built in function generator in a compact form factor at an affordable price 4 genera tion MegaZoom technology enables the industry s fastest waveform update rate with responsive deep memory acquisitions Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Do more with the power of 4 instruments in 1 Best in class oscilloscope aro The InfiniiVision 3000 X Series features the deepest memory in its class with up to 4 Mpts of Agilent s patented MegaZoom WV technology that is always enabled and always responsive providing the industry s fastest update rate at up to 1 million waveforms per second with no compromise if you turn on measurements or add digital channels i aq gr A In addition the 3000 X Series offers 33 automated mea surements nine parametric triggers six serial protocol triggers as well as seven waveform math functions including FFT All of this at a comparable price to the Tektronix DP02000 oscilloscope Industry s only upgradable integrated mixed signal oscilloscope MSO Agilent The 3000 X Seri
25. s 250 ps at all timebase settings Averaging Selectable from 2 4 8 16 64 to 65 536 High Resolution Mode 12 bits of resolution when 210 us div at 4 GSa s or 20 us div at 2 GSa s Segmented optional Re arm time 1 us minimum time between trigger events Waveform measurements All 3000 X Series models Characteristics Cursors e Single cursor accuracy DC vertical gain accuracy DC vertical offset accuracy 0 25 full scale e Dual cursor accuracy DC vertical gain accuracy 0 5 full scale Automatic measurements Measurements continuously updated with statistics Cursors track last selected measurement Select up to four measurements from the list below e Voltage peak to peak maximum minimum amplitude top base overshoot pre shoot average N cycles average full screen DC RMS N cycles DC RMS full screen AC RMS N cycles AC RMS full screen standard deviation ratio RMS1 RMS2 e Time period frequency counter width width burst width duty cycle rise time fall time delay phase X at min Y X at Max Y e Count positive pulse count negative pulse count rising edge count falling edge count e Mixed area N cycles area full screen Counter Built in frequency counter e Source on any analog or digital channel e Resolution 5 digits e Maximum frequency bandwidth of scope Waveform math All 3000 X Series models Characteristics Arithmetic f g t g t 1 2 3 4 1 2 1 2 1x2
26. scilloscope functions allow technicians to spend more time testing and less time learning where the menus are on the oscilloscope Enable your technicians to answer their own questions with the localized built in help system that provides quick access by simply pressing and holding any button Faster low failed device escape test throughput With the fastest architecture in its class featuring up to 1 000 000 waveforms sec you will capture more of those elusive problems you worry about and ensure they don t ship to customers With the mask limit testing measure ment application you can quickly test up to 280 000 waveforms per second to a known good waveform with a quick go no go test results saving you valuable test time while having more certainty Optimize test bench space With 4 instruments in 1 you will save on precious line bench space by getting an oscilloscope logic timing ana lyzer protocol analyzer and WaveGen function generator all in one innovative instrument with a footprint that is only 5 57 inches deep With the large 8 5 inch WVGA display you can easily view all signals on one screen even when the scope is sitting far away from the operator Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget MSO X 3054A 500 MHz ay Agilent Technologies InfiniiVision Mixed Signal Oscilloscope 4 GSa s 1 280V 2 5 60V a 0 0s 500 047 Stop Time Serial 2 VART a Mee 8 5 inch high
27. ss with upgradable bandwidth 16 digital channels MSO Lab Guide and Tutorial for upgradable WaveGen and measurement applications Get a Undergraduate Electrical Engineering and Physics long scope life and keep repair costs to a minimum with a Students standard 3 year warranty and an instrument reliability you ve come to expect from the leader in test and measurement equipment lt Agilent Technologies Optimize lab bench space With 4 instruments in 1 you will save on precious lab bench space by getting an oscilloscope logic timing ana lyzer protocol analyzer and WaveGen function generator all in one innovative instrument with a footprint that is only 5 57 inches deep With the large 8 5 inch WVGA display you can easily view all signals on one screen with enough viewing area for more than one student to view Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Designed with manufacturing in mind Stretch a limited budget Project needs change but traditional oscilloscopes are fixed you get what you pay for at time of purchase With the 3000 X Series your investment is protected If you need more bandwidth up to 500 MHz or measurement applications like mask testing in the future you can easily add them all when you need it Get your technicians to quickly put the scope to work Intuitive localized front panel design and pushable knobs for quick access to commonly used o
28. tional Option DSOX3MemUp Waveform update rate 50 000 waveforms per second 1 000 000 waveforms per second Digital timing channels 8 on MSO models or with 16 on MSO models or with DSOX2MSO upgrade DSOX3MSO upgrade WaveGen built in 20 MHz Yes Option DSOX2WAVEGEN Yes Option DSOX3WAVEGEN function generator Search and navigate No Yes Serial protocol analysis No Yes multiple options Segmented memory Yes Option DSOX2SGM Yes Option DSOX3SGM Mask limit testing Yes Option DSOX2MASK Yes Option DSOX3MASK AutoProbe interface No Yes Need more memory or bandwidth See the InfiniiVision 000B Series oscilloscopes e 2 or 4 analog channels plus an optional 16 digital channels e 100 MHz 1 GHz bandwidth e 8 Mpts memory standard e Search and navigate capability e Serial protocol analysis application available e FPGA dynamic probe application available See www agilent com find 7000 for more details Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget More scope The InfiniiVision 3000 X Series offers entry level price points to fit your budget with superior performance and optional capabilities that are not available in any other See more of your signal more of the time with the oscilloscope in its class Our breakthrough technology largest screen in its class the deepest memory and delivers more scope for the same budget the fastest waveform update rates With more scope you can Do mo
29. ust by pressing and hold ing any button Probe solutions and compatibility Get the most out of your 3000 X Series scope by using the right probes and accessories for your application Agilent offers a complete family of innovative probes and accessories for the InfiniiVision 3000 X Series scopes For the most up to date and complete information about Agilent s probes and accessories visit our Web site at www agilent com find scope_probes Also available is the N2744A T2A Tektronix TekProbe interface to Agilent AutoProbe probe interface adapter This adapter allows users of Tektronix TekProbe active probes to connect directly to the InfintiVision 3000 X Series AutoProbe interface BNC input Protect your previ ous probe investment while taking advantage to the InfiniiVision 3000 X Series unique capabilities and value Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Other productivity tools Autoscale Quickly display any active signals and automatically set the vertical horizontal and trigger controls for optimal viewing with the press of the autoscale button This feature can be disabled or enabled for the education environment Connectivity Built in USB host on front one back and USB device ports make PC connectivity easy Operate the scope from your PC and save and recall stored waveforms as well as set up files via LAN An optional LAN VGA module gives you network
30. y delivers more scope for the same budget Configuring your InfiniiVision X Series oscilloscope Step 1 Choose your bandwidth number of channels and memory depth InfiniiVision 3000 X Series scopes DSOX3012A DSOX3014A DSOX3024A DSOX3032A DSOX3034A DSOX3052A DSOX3054A MS0X3012A MSOX3014A MSOX3024A MSOX3032A MSOX3034A MSOX3052A MSOX3054A Bandwidth 100 MHz 100 MHz 200 MHz 350 MHz 350 MHz 500 MHz 500 MHz upgradable Analog 2 4 4 2 4 2 4 channels Digital channels 16 integrated digital channels optional MSO Memory 2 Mpts half channel standard or 4 Mpts half channel DSOX3MEMUP Step 2 Tailor your scope with measurement applications to save time and money Application 3000 X Series WaveGen built in function generator DSOX3WAVEGEN Educator s kit DSOXEDK Mask testing DSOX3MASK Segmented memory DSOX3SGM Embedded serial triggering and analysis I C SPI DSOX3EMBD Computer serial triggering and analysis RS232 422 485 UART DSOX3COMP Automotive serial triggering and analysis CAN LIN DSOX3AUTO Audio serial triggering and analysis IS DSOX3AUDIO Power measurement and analysis U1881A PC offline viewing B4610A Step 3 Choose your probes Probes 3000 X Series N2862B Passive probe 150 MHz 10 1 attenuation N2863B Passive probe 300 MHz 10 1 attenuation N2890A Passive probe 500 MHz 10 1 attenuation N6450 60001 16 digital channel MSO cable N2889A passive probe 350 MHz 10 1 1 1 switchable attenuation 10076B passive prob

Download Pdf Manuals

image

Related Search

Related Contents

  Easylon USB Interface User Manual  Télécharger    Règlement intérieur Service expérimental Lila+ - Lila Loire  Craftsman 272 Lawn Mower User Manual  Central Hydraulics 66593 User's Manual  Guia de instalação  Préparer un salon - fiche 2 Mode d`emploi  

Copyright © All rights reserved.
Failed to retrieve file