Home

User Instruction Manual

image

Contents

1. Battery Information The display showing full battery means that the battery is fully charged and the lift is ready for use The display showing a half empty battery indicates that it is time to charge the battery The empty battery symbol showing on the display indicates that the battery has no capacity left and should be placed on charge immediately AWARNING To avoid possible permanent damage to the battery the battery should be placed on charge as soon as the display indicates the half empty battery symbol Oxford English Smart Monitor 5 Warranty Joerns Healthcare has an established network of reputable distributors and dealers who will be pleased to handle all your purchasing warranty repair and maintenance enquiries This product is guaranteed for a period of twelve months from the date of manufacture or twelve months from the date of purchase if commissioned by an authorised dealer We recommend that all of our products are commissioned by your dealer and are supported by them for future servicing The dealer or distributor operates the warranty programme so it is important to keep a record of their name address and telephone number so they can be contacted should any problem arise If you are in doubt as to where your product was purchased Joerns Healthcare can trace the supplier if you quote the serial number of the lift Contact details can be found on the rear cover of this manual REMEMBER Conta
2. Fig 2 NOTE The Oxford Smart Monitor can only be operated with the User Handset supplied In the event of the User Handset becoming faulty or damaged you may continue to use the lift for a short period of time until the User Handset has been replaced by using the emergency redundant controls located beneath the emergency stop button on the Smart Monitor Fig 3 NOTE If the User Handset becomes faulty or damaged contact your authorised Oxford service provider immediately to arrange a replacement Emergency Stop Button Redundant Control Emergency Raise Redundant Control Emergency Lower Redundant Control Legs Open Model dependent Redundant Control Legs Close Model dependent Fig 3 Oxford Smart Monitor 5 Smart Monitor Display The Oxford Smart Monitor has the option to read out information via the LCD display screen It is possible to read out total lifting cycles total work done overloads and number of days since last service which can be used to quickly and easily evaluate the condition of the lift actuator This information is accessed by a Y second press on the RAISE button on the User Handset or redundant RAISE button on the Smart Monitor 12034 Total Lifting Cycles 1257000 Total Work Done Amps Seconds 7 Number of Overloads 90 180 Number of Days since last service Number of Days between services Service amp Usage Information When it i
3. Joerns Oxford User Instruction Manual Oxford Smart Monitor To avoid injury read user manual prior to use Oxford Smart Monitor SR Contents 1 Introduction About Your Produg ss 3 23 ee Bund A 3 Assembly amp Commissioning Instructions ocoonocccinincccinocccnnnccnconancnnonannnnonannnnanononnana canon 5 4 User Handset Operating Instructions 6 5 Operating Instructions Smart Monitor 7 6 E 7 1 118 EE 9 Oxford English Smart Monitor 1 Introduction About Your Product Please ensure you take time to read this manual thoroughly before using your Oxford Smart Monitor This will help ensure both patient and carer remain safe and free from injury throughout the lifting and transfer process as well as to familiarise yourself with the product s features and functions If you are unsure on the use of this product or any specific element please contact your local authorised service provider or Joerns Healthcare for further advice A WARNING Do not attempt to use the Oxford Smart Monitor without first understanding this manual The CE Mark The Oxford Smart Monitor carries the CE mark and complies with the following EC directives e Medical Device Directive 93 42 EEC C EMC Directive 89 336 EEC Electrics only e Low Voltage Directive 73 23 EEC Electrics only Statement of Intended Use The Oxford Smart Monitor is a control system for Oxford patient lifts It stores
4. ct your distributor for purchases warranty repairs servicing and certified maintenance Your distributor O Joerns Oxford Joerns Healthcare Limited Drakes Broughton Business Park Worcester Road Drakes Broughton Pershore Worcestershire WR10 2AG United Kingdom T 0844 811 1156 F 0844 811 1157 www joerns co uk email info joerns co uk 2014 Joerns Healthcare 294000 10379 Rev C DCO14 0003
5. mponents are included with the Smart Monitor Retro fit Kit 1x Oxford Smart Monitor 1x User Handset 1x M5 x 8mm Long Fixing Screw e 1 x Battery Pack 1x User Manual NOTE The Oxford Smart Monitor can only be operated with the User Handset supplied WARNING The Oxford Smart Monitor requires calibrating prior to use Specific calibration is dependent on lift type and must be performed by an authorised service provider only Failure to do this may result in serious injury to the patient and or caregiver AWARNING The User Handset supplied with the Smart Monitor control box cannot be used in conjunction with a standard control box Oxford Smart Monitor English 4 Operating Instructions The day to day functionality of your lift is not affected by the installation of the Oxford Smart Monitor This section covers the basic lift operations AWARNING Refer to your lift s user guide for full operating instructions safety guidance and daily checks prior to lifting and transferring patients AWARNING DO NOT exceed the safe working load of the lift and or sling To raise or lower the boom following the retro fit of an Oxford Smart Monitor simply press the raise and lower buttons on the User Handset Fig 2 If your lift incorporates powered leg positioning the legs can be opened closed using the appropriate button on the User Handset Fig 2 Legs Open U ww Legs Close Model dependent Model dependent
6. s time for a service the service symbol will appear on the display In addition when the User Handset is activated the Smart Monitor will give an audible signal giving notice to users that a service is required SERVICE The service symbol will be displayed each time the raise or lower keys are depressed on the User Handset When the service symbol is displayed contact your authorised service provider immediately to arrange a service You may continue to use your lift for a short period of time until a service has been carried out If the lift stops because of an overload an attempt to lift more than the safe working load the overload symbol will appear on the LCD display and the lift will cease to operate until the additional load above the SWL has been removed AWARNING If the LCD display screen on your Smart Monitor has recorded an overload Joerns Healthcare recommend that ALL routine daily checks are carried out on the lift prior to further use for a list of daily checks please refer to your lift user manual Joerns Healthcare also recommend that you contact your authorised Oxford service provider for additional guidance MAX Oxford Smart Monitor On Board Redundant Controls On board redundant controls enable the lift to be raised or lowered in Ze the event of an emergency e 0 ch If your lift incorporates powered leg positioning there are redundant controls to both open and close the legs
7. useful servicing information about the lift that can be recalled when required This servicing information includes Number of patient lift cycles Total work done by actuator Number of lift overloads attempted lifts above the safe working load Number of days since last service interval The Smart monitor replaces the existing control box and is fully compatible and retro fitable to the following Oxford patient lifts manufactured post 2003 fitted with a Linak actuator Oxford Mini Oxford Journey Oxford Presence Oxford Midi Oxford Elevate Oxford Calibre Oxford Major Oxford Ascend Oxford Advance e Oxford Maxi Oxford Stature For products not listed above please consult Joerns Healthcare to verify and confirm compatibility AWARNING DO NOT attempt to install a Smart Monitor Control box on a lift that is not listed above without consulting Joerns Healthcare for advice Oxford Smart Monitor English 2 Oxford Smart Monitor Emergency Stop Button Raise amp Lower Buttons Legs Open Close Buttons Emergency Raise 8 Lower Model dependent Redundant Controls User Handset Legs Open Close Redundant Controls Model dependent User Handset Connection Socket LCD Information Screen Actuator Connection User Handset Socket Connection Plug Fig 1 Oxford Smart Monitor Jlish En Q 3 Assembly amp Commissioning Instructions The following co

Download Pdf Manuals

image

Related Search

Related Contents

CONGRATULATIONS!  kpc-ew650u user guide  BIP 49  PCNET - SAS User Guide  取扱説明書 GIVI PLX351  Desktop Messaging User Guide for My CallPilot  NEXAVAR V1_6pat    

Copyright © All rights reserved.