General requirements

image

Contents

1. Class IIl product intended for building in No safety related controls or indicators Class IIl product intended for building in Not directly connected to Mains No such components Class IIl product intended for building in Marked ratings not required 1 7 12 Removable parts No such components 1 7 14 Thermostats and other regulating devices Replaceable batteries ssesssssss Language S rr temp terius Equipment for restricted access locations No such components To be provided in the appropriate language of the country of use Only English language installation has been reviewed Not intended for such location Product Service N A N A N A N A N A N A N A N A N A N A N A N A N A Page 8 of 45 Report Ref No 090 907721 000 Product Service 2 PROTECTION FROM HAZARDS mE 2 1 Protection from electric shock and energy hazards 2 1 1 Protection in operator access areas Class III product intended for N A building in Not directly connected to Mains 2 1 1 1 Access to energized parts Class III product intended for N A building in To be evaluated in the end application Test by inspection EE N A Test with test finger Figure 2A N A Test with test pin Figure 2B Po N A
2. Quantity of liquid I esses Flash point C ssseeee 3 13 lonizing radiation No radiation of any type Measured radiation pA kg Measured high voltage KV Measured focus voltage KV CRT markings DERE edere cens 4 3 13 3 Effect of ultraviolet UV radiation on materials No generavtion of UV Part property retention after test flammability ClASSITIGATION ssis sinian aan aaaea Human exposure to ultraviolet UV radiation No generation of UV 9 13 Laser including LEDs No lasers Laser class cse uere eiui Other types sssssssssseeeee enne i Protection against hazardous moving parts A General No moving parts No radiation of any type Protection in operator access areas Protection in restricted access locations Protection in service access areas Thermal requirements General Considered Temperature tests Conducted with satisfactory results Normal load condition per Annex L o ojo RIRIRIRIR eo w Co eo eo w w wo D KR oO PM oo w w co oo mic o Oo ajA N N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A
3. b EUT whose telecommunication ports have no s to protective earth Electric strength EE 5 3 4 Page 22 of 45 Report Ref No 090 907721 000 Product Service General Refer to appended table 5 2 Model A200 Basic insulation required from TNV 3 to SELV and enclosure verified Abnormal operating and fault conditions gt Protection against overload and abnormal operation Class III product intended for building in Not directly connected to Mains Single fault testing only relevant in the end application Transformers No wire wound transformers N A provided insulation relied on for safety Functional insulation Method c evaluated No testing conducted as PCB is V 0 and condition of acceptability includes a fire enclosure to be provided in the end system N No audio amplifiers Simulation of faults To be evaluated in the end application Unattended equipment To be evaluated in the end application Compliance criteria for abnormal operating and To be evaluated in the end fault conditions application During the tests MEE After the tests Ooo O N N N N A A A A A A N Page 23 of 45 Report Ref No 090 907721 000 Product Service CONNECTION TO TELECOMMUNICATION NETWORKS Protection of telecommunication network service persons and users of other equipment connected to the network from hazards in the equipment
4. 90 AFTBas PCBnearUt7 822 w AFTBae POBmeaJ 266 w AFT Base PCB near C9 o 105 got os T2 enclosure 308 1 T1 enclosure 6 EN Component S9 305 PCI coverplate 260 Model A108 CRE Base PGB nearest AFT Base PCB nero 0 AFT ease PCB nears J AF BmePCBwarc Je Ruermbey Je Teweue Teencoswe J RBmau TE Gaweens 342 PGewmpme i54 Page 43 of 45 Report Ref No 090 907721 000 Product Service Continued OP 3 3Vdc 5 0Vdc La Maximum measured temperature T of part at Allowed Tmax C AFTBase POBnearU2t 388 AFTBase PCBnearUi7 343 J 15 AFTBasePCBmea Co saj 10 J AFTRemore PCBnearR23 289 J 105 AFTRemora PCBnearDi1 306 AFTRemoe PCBmearUi 313 J t0 FX0 5 daughter card S6 9326 FX0 5 daughter card PCB near C37 313 105 FXS daughter card S28 se 105 PXSdeghtrcad L3 fesal t5 POlewepae 265 7 Supplementary information The units were tested inside a desktop computer model Hewlett Packard a6030n while running looping software Mo
5. Report Reference No 090 907721 000 Page 10 of 16 2009 11 12 Attachment No 2 Product Service Model A108 Front External View Main Card Amd E Report Reference No 090 907721 000 Page 11 of 16 2009 11 12 Attachment No 2 C Product Service Model A108 Front External View Daughter Card Report Reference No 090 907721 000 Page 12 of 16 2009 11 12 Attachment No 2 2 Product Service Model A108 Main Card Bottom Daughter Card Top Report Reference No 090 907721 000 Page 13 of 16 2009 11 12 Attachment No 2 C Product Service Model A200 Front External View Main Card J FT am CLLLELEEE EEE EEE EEE C CELTEEEEE sancu 4aG ORA Report Reference No 090 907721 000 Page 14 of 16 2009 11 12 Attachment No 2 TOV Product Service Model A200 Daughter Cards FXS Left FXO 5 Right AFT REMORA MODEL A200 REV Report Reference No 090 907721 000 Page 15 of 16 2009 11 12 Attachment No 2 TOV Product Service Model A200 Main Card Top Daughter Card Bottom AFT REMORA MODEL A200 REV Report Reference No 090 907721 000 Page 16 of 16 2009 11 12 Attachment No 2
6. Sweden Ordinance 1990 944 Add the following NOTE In Sweden switches containing mercury are not permitted In Sweden resistors bridging BASIC Class IIl equipment intended for INSULATION in CLASS I PLUGGABLE building in Not connected directly EQUIPMENT TYPE A must comply with the to Mains requirements in 1 5 7 2 In Sweden the third dashed sentence is No VDR s applicable only to equipment as defined in 6 1 2 2 of this annex National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 21 of 33 uv Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark 1 7 2 1 In Sweden CLASS PLUGGABLE EQUIPMENT Class Ill equipment intended for TYPE A intended for connection to other building in Not connected directly equipment or a network shall if safety relies on to Mains connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts have a marking stating that the equipment must be connected to an earthed mains socket outlet The marking text in the applicable countries shall be as follows Apparaten skall anslutas till jordat uttag annex UL CSA 60950 1 and provide Basic insulation Tested at 1 5kV 2 10 5 13 In Sweden there are additional requirements for No insulating compound relied on as the insulation see 6 1 2 1 and 6 1 2 2 of this
7. e Page 19 of 45 Report Ref No 090 907721 000 Product Service A o C 5 Temperature limits for materials Refer to appended table 4 5 5 Touch temperature limits Refer to appended table 4 5 Resistance to abnormal heat No thermoplastic part supporting hazardous voltages Openings in enclosures 6 Top and side openings To be evaluated in the end application Dimensions mm Constructional design measures BOR ALS o ala SENS A D wo 4 6 2 Dimensions mm Evaluation measures for larger openings Use of metallized parts Adhesives for constructional purposes pl A RS a Om Oo OD A AR TIR oii A Conditioning temperature C time weeks Resistance to fire Reducing the risk of ignition and spread of flame Class III product intended for building in To be evaluated in the end appliction Method 1 selection and application of components Mounted on 94V 0 PCB wiring and materials Method 2 application of all of simulated fault Method 1 applied condition tests Conditions for a fire enclosure Class III product intended for building in Not directly connected to Mains Fire enclosure to be provided in the end application 7 2 Parts requiring a fire enclosure fo oS 7 2 Parts not requiring a fire enclosure Pa
8. Test Result Remark add the following text between the first and Model A200 Bridging Y2 capacitors second paragraph of the compliance clause from TNV to SELV are approved to UL CSA 60950 1 and provide Basic If this insulation is solid including insulation g insulation Tested at 1 5kV forming part of a component it shall at least consist of either two layers of thin sheet material each of which shall pass the electric strength test below or one layer having a distance through insulation of at least 0 4 mm which shall pass the electric strength test below If this insulation forms part of a semiconductor component e g an optocoupler there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing so that CLEARANCES and CREEPAGE DISTANCES do not exist if the component passes the electric strength test in accordance with the compliance clause below and in addition 5 passes the tests and inspection criteria of 2 10 11 with an electric strength test of 1 5 kV multiplied by 1 6 the electric strength test of 2 10 10 shall be performed using 1 5 kV and is subject to ROUTINE TESTING for electric strength during manufacturing using a test voltage of 1 5 kV It is permitted to bridge this insulation with a capacitor complying with EN 132400 1994 subclass Y2 A capacitor classified Y3 according to EN 132400 1994 may bridge thi
9. Test with test probe Figure 2C N A 2 1 1 2 Battery compartments No such compartment N A 2 1 1 3 Access to ELV wiring N A Working voltage Vpeak or Vrms minimum distance through insulation mm 2 1 1 4 Access to hazardous voltage circuit wiring To be evaluated in the end N A application 2 1 1 5 Energy hazards seen No energy hazards present N A 2 1 1 6 Manual controls The equipment has no N A manual controls connected to hazardous voltages 2 1 1 7 Discharge of capacitors in equipment No mains supply voltage N A Measured voltage V time constant s LC b Internal battery connected to the d c mains EE N A SUPPIV 2 1 1 9 Audio amplifiers nn N A SELV circuits General requirements All SELV to be provided by N A separately approved power supply to be provided in the end application Voltages under normal conditions V All voltages are less than N A 42 4Vp or 60Vdc and are classified as SELV with the exception of the TNV3 circuit in Model A200 Page 9 of 45 Report Ref No 090 907721 000 Product Service 2 2 3 Voltages under fault conditions V All SELV to be provided by N A separately approved power supply to be provided in the end application 2 2 4 Connection of SELV circuits to other circuits SELV circuits i
10. Remark In the event of a single fault between TNV and Model A200 Bridging Y2 capacitors SELV circuits the limits of 2 2 3 apply to SELV from TNV to SELV are approved to Circuits and accessible conductive parts UL CSA 60950 1 and provide Basic insulation Tested at 1 5kV Protective bonding conductors of non standard Class IIl equipment intended for protective bonding constructions e g printed building in Not connected directly circuit traces may be subjected to the additional t Mains limited short circuit test conditions specified 4 2 8 1 Enclosures around CRTs with a face diameter No CRT s N of 160 mm or more are required to reduce the risk of injury due to the implosion of the CRT 4 2 11 For equipment intended for mounting on racks Class Ill equipment intended for N and provided with slide rails allowing the building in Not connected directly equipment to slide away from the rack for to Mains Not directly rack installation service and maintenance additional mounted construction performance and marking requirements are applicable to determine the adequacy of the slide rails Equipment with handles is required to comply No handles Equipment intended N with special loading tests for building in Equipment intended to receive Class IIl equipment intended for telecommunication ringing signals is required to building in Not connected directly comply with a special touch current to Mains measurement test
11. Vertically mounted disconnect switches and No vertically mounted disconnect circuit breakers are required to have the on switches or circuit breakers position indicated by the handle in the up For computer room applications equipment with Equipment intended for building in battery systems capable of supplying 750 VA for five minutes are required to have a battery disconnect means that may be connected to the computer room remote power off circuit The maximum quantity of flammable liquid No liquids stored in equipment is required to comply with NFPA 30 4 3 13 5 Equipment with lasers is required to meet the No such lasers Canadian Radiation Emitting Devices Act REDR C1370 and or Code of Federal Regulations 21 CFR 1040 as applicable For computer room applications automated Not an automated information information storage Systems with combustible storage system media greater than 0 76 m 27 cu ft are required to have a provision for connection of either automatic sprinklers or a gaseous agent extinguishing system with an extended discharge For computer room applications enclosures with combustible material measuring greater than 0 9 m 10 sq ft or a single dimension greater than 1 8 m 6 ft are required to have a flame spread rating of 50 or less For other applications enclosures with the same dimensions require a flame spread rating of 200 or less National Differences IEC 60950 1 2nd ed Rev 0
12. Adequate wire bending space and volume of field wiring compartment required to properly make the field connections Equipment solely for installation in Restricted Access Locations using low voltage d c systems may not need provision for connecting and securing a field wiring system when wiring is protected from abuse Field wiring terminals provided for interconnection of units for other then LPS or Class 2 circuits also comply with 3 3 Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended f
13. Equipment for use on a c mains supply systems Class III equipment intended for with a neutral and more than one phase building in Not connected directly conductor e g 120 240 V 3 wire require a to Mains special marking format for electrical ratings A voltage rating that exceeds an attachment plug cap rating is only permitted if it does not exceed the extreme operating conditions in Table 2 of CAN CSA C22 2 No 235 and if it is part of a range that extends into the Table 2 Normal Operating Conditions Likewise a voltage rating shall not be lower than the specified Normal Operating Conditions unless itis part of a range that extends into the Normal Operating Conditions National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 5 of 33 Report Reference No 090 907721 000 Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Wiring terminals intended to supply Class 2 outputs in accordance with CEC Part 1 or NEC shall be marked with the voltage rating and Class 2 or equivalent Marking shall be located adjacent to the terminals and shall be visible during wiring Where a fuse is used to provide Class 2 Limited Power Source or TNV current limiting it shall not be operator accessible unless it is not interchangeable Suitable NEC CEC branch circuit protection rated at the maximum circuit rating is required for all standard supply outlets and receptacles such as supplied in power distribu
14. Protection from hazardous voltages o o uA E gana 6 1 2 Separation of the telecommunication network from earth 6 1 2 1 Requirements Model A200 Bridging Y2 7 capacitors from TNV3 to SELV are approved to UL CSA 60950 1and IEC 60384 14 and are certified by UL and Semko and are considered acceptable to provide Basic insulation Supply voltage V 2 5 Not powered from AC mains Current in the test circuit mA Not powered from AC mains N A 6 1 2 2 6 2 Protection of equipment users from overvoltages on telecommunication networks 6 2 1 Separation requirements Basic insulation provided as P mentioned above Electric strength test procedure 1500Vac 2121Vdc P 6 2 2 1 Impulse test 1500Vrms from ring tip to P enclosure and PCI slots 6 2 2 2 Steady state test 2121Vdc from ring tip to P enclosure and PCI slots 6 2 2 3 Compliance criteria No breakdown P 6 3 Protection of the telecommunication wiring system from overheating Max output current A No wiring system a EX CIUSIONS ete eoe ieee node nn des Current limiting method Page 24 of 45 Report Ref No 090 907721 000 Product Service N A Protection of cable distribution system service N A persons and users of other equipment connected to the system from hazardous voltages in the equipment Protection of equipment users from
15. ho gt M 3 2 Tripping device and monitoring voltage M 3 2 1 Conditions for use of a tripping device or a monitoring voltage M 3 2 2 Tripping device M 3 2 3 Monitoring voltage V sees i w gt Page 29 of 45 Report Ref No 090 907721 000 Product Service N ANNEX N IMPULSE TEST GENERATORS see 1 5 7 2 1 5 7 3 2 10 3 9 6 2 2 1 7 3 2 7 4 3 and Clause G 5 ITU T impulse test generators Equipment Keytek EMC Pro oed Plus ANNEX P NORMATIVE REFERENCES ANNEX Q Voltage dependent resistors VDRs see 1 5 9 1 a Preferred climatic categories NO VDR S b Maximum continuous voltage PN c Pulse current eeeeeeeessssees PN ANNEX R EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL PROGRAMMES R 1 Minimum separation distances for unpopulated Quality system not relied on N A coated printed boards see 2 10 6 2 for reduced creepage and clearances R 2 Reduced clearances see 2 10 3 as S ANNEX S PROCEDURE FOR IMPULSE TESTING see 6 2 2 3 Test equipment Annex S not relied upon N A S 3 Examples of waveforms during impulse testing ERN N A T ANNEX T GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER N A see 1 1 2 ANNEX U INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION see 2 10 5 4 Annex U not relied upon V ANNEX V AC POWER DISTRIBUTION SYSTEMS see
16. 10 Aand up to Mains to and including 13 A National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 16 of 33 uv Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark In the United Kingdom the range of conductor Class IIl equipment intended for sizes of flexible cords to be accepted by terminals building in Not connected directly for equipment with a RATED CURRENT of over to Mains 10 A up to and including 13 A is 1 25 mm to 1 5 mm nominal cross sectional area In the United Kingdom the torque test is Class Ill equipment intended for performed using a socket outlet complying with building in Not connected directly BS 1363 part 1 1995 including Amendment to Mains 1 1997 and Amendment 2 2003 and the plug part of DIRECT PLUG IN EQUIPMENT shall be assessed to BS 1363 Part 1 12 1 12 2 12 3 12 9 12 11 12 12 12 13 12 16 and 12 17 except that the test of 12 17 is performed at not less than 125 C Where the metal earth pin is replaced by an Insulated Shutter Opening Device ISOD the requirements of clauses 22 2 and 23 also apply In Ireland apparatus which is fitted with a flexible Class IIl equipment intended for cable or cord and is designed to be connected to building in Not connected directly a mains socket conforming to I S 411 by means to Mains of that flexible cable or c
17. China CQC CZ Czech Republic Yes EZU Yes DE Germany DIN EN 60950 1 VDE805 1 VDE T V RHEINLAND T V S D PS SLG LGA ETS DK Denmark UL Yes Yes DS EN 60950 1 International Demko A S Yes Yes FI Finland Yes Yes EN 60950 1 SGS FIMKO Yes Yes FR France Yes LCIE Yes GB United Kingdom EN 60950 1 ASTABEAB BSI eneee fe OOO HU Hungary MEEI IL Israel SII IN India STQC IT Italy Yes IMQ S p a Yes National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 3 of 33 TOV Report Reference No 090 907721 000 Date of issue 2009 11 12 Product Service TUV Japan JQA JET UL Apex KR Korea Yes K 60950 1 KTL Yes KETI Yes ERI Yes MY Malaysia SIRIM NL Netherlands Yes KEMA Yes NO Norway Yes Yes EN 60950 1 NEMKO Yes Yes PL Poland PN EN 60950 1 BBJ SEP SE Sweden Yes Yes SS EN 60950 1 2 ed SEMKO Yes Yes SG Singapore PSB Corp SI Slovenia SIQ SK Slovakia EVPU US United States of America UL 60950 1 2007 UL MET ITS TUV RH NA National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 4 of 33 uv Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark Canada and the United States of America have adopted a single bi national standard CAN CSA C22 2 No 60950 1 UL60950 1 Second Edition which is based on IEC 60950 1 Second Edition This bi national standard sh
18. Headphones and earphones associated with portable audio equipment Maximum sound pressure level measurement methodology and limit considerations Part 1 General method for one package equipment and in EN 50332 2 Sound system equipment Headphones and earphones associated with portable audio equipment Maximum sound pressure level measurement methodology and limit considerations Part 2 Guidelines to associate sets with headphones coming from different manufacturers the EU see Directive 2002 95 EC 1 7 2 1 Add the following NOTE NOTE Z1 In addition the instructions shall include as far as applicable a warning that excessive sound pressure from earphones and headphones can cause hearing loss Replace the subclause as follows Basic requirements To protect against excessive current short circuits and earth faults in PRIMARY CIRCUITS protective devices shall be included either as integral parts of the equipment or as parts of the building installation subject to the following a b and c a except as detailed in b and c protective devices necessary to comply with the requirements of 5 3 shall be included as parts of the equipment b for components in series with the mains input to the equipment such as the supply cord appliance coupler r f i filter and switch short circuit and earth fault protection may be provided by protective devices in the building installation Add the following NOTE NOTE Z1 The use of certa
19. Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to Mains National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Product Service Requirement Test Result Remark Page 6 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark 3 3 Wiring terminals and associated spacings for Equipment intended for building in field wiring connections shall comply with CSA C22 2 No 0 3 3 3 Wire binding screws are not permitted to attach conductors larger than 10 AWG 5 3 mm 3 3 4 Terminals for permanent wiring including protective earthing terminals are required to be suitable for Canadian US wire gauge sizes rated 125 percent of the equipment rating and marked when specified 1 7 7 Motor control devices are required for Not a motor control device cord connected equipment with a motor if the equipment is rated more than 12 A or if the motor has a nominal voltage rating greater than 120 V or is rated more than 1 3 hp locked rotor current over 43 A
20. Mains Permitted use for flexible cords and plugs Class III equipment intended for building in Not connected directly to Mains Flexible cords provided with attachment plug Class III equipment intended for rated 125 of equipment current rating building in Not connected directly to Mains Any Class Il equipment provided with 15 or 20 Class III equipment intended for standard supply outlets Edison base building in Not connected directly lampholders or single pole disconnect device to Mains provided with a polarized type attachment plug Equipment intended for connection to DC mains Class III equipment intended for supply power systems complies with special building in Not connected directly wiring requirements to Mains Equipment with one pole of the DC mains supply Class Ill equipment intended for connected to both the equipment mains input building in Not connected directly terminal and the main protective earthing terminal t Mains provided with special instructions and construction provisions for earthing Equipment with means for connecting supply to Class III equipment intended for earthing electrode conductor has no switches or building in Not connected directly protective devices between supply connection to Mains and earthing electrode connection Markings and instructions for equipment with Class III equipment intended for provisions to connect earthed conductor of a DC building in Not connected d
21. Manufacturer sssseeeseeeeeneennnne 2 mue EE Protection from displacement of windings PN ol O ND Page 27 of 45 D Report Ref No 090 907721 000 Product Service ANNEX D MEASURING INSTRUMENTS FOR TOUCH CURRENT TESTS see 5 1 4 D 1 Measuring instrument Class III product intended for N A building in Not directly connected to Mains Single fault testing only relevant in the end application ANNEX E TEMPERATURE RISE OF A WINDING see 1 4 13 N A F ANNEX F MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES N A see 2 10 and Annex G G ANNEX G ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES e ome O M G 1 2 Summary of the procedure for determining N A minimum clearances G 2 Determination of mains ransien wotage y NA G 2 1 AG mains Supply 2 ricette tend restes Po N A G 2 2 Earthed d c mains supplies EN Se N A G 2 3 Unearthed d c mains supplies Pe N A G 2 4 Battery operation PE N A G 3 Determination of telecommunication network N A transient voltage V esee 6 42 Transients rom tetecommunication networks MA G4s Combination of ransiems N G44 Transients trom cable distribution systems MA G5 Measurement ofvansientvolages MA fe Transients from a mais supp MA Foran ae mains supp M
22. No insulating compound relied on as the insulation see 6 1 2 1 and 6 1 2 2 of this solid insulation National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 18 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark In Norway TOUCH CURRENT measurement Class IIl equipment intended for results exceeding 3 5 mA r m s are permitted building in Not connected directly only for the following equipment to Mains STATIONARY PLUGGABLE EQUIPMENT TYPEA that o is intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied for example in a telecommunication centre and e has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and o is provided with instructions for the installation of that conductor by a SERVICE PERSON e STATIONARY PLUGGABLE EQUIPMENT TYPE B STATIONARY PERMANENTLY CONNECTED EQUIPMENT National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 19 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark In Norway add the following text between the first and Model A200 Bridging Y2 capacitors second paragraph of the compliance clause from TNV to SELV are approved to If this insulation is solid including ins
23. S i Sample 3 burning time S Ce p omm 1001 500102 RR T i Sample 1 burning time S NEN EE Sample 2 burning time S OoOo EE ee 3 eer time S treten irre ANN AS Hottamingoitestisee462 NA Asi Mouning otsampls MA Aaa remeare M aas Complance geo NA RE E ANNEX B MOTOR TESTS UNDER ABNORMAL CONDITIONS see 4 7 2 2 and Ds 5 3 2 Page 26 of 45 Report Ref No 090 907721 000 Product Service Ic MM qp Maximum temperatures Running overload test Locked rotor overload test Test duration days sees B 3 B 4 Electric strength test test voltage V Running overload test for d c motors in secondary circuits B 6 2 Test procedure B 6 3 Alternative test procedure B 6 4 Electric strength test test voltage V Locked rotor overload test for d c motors in secondary circuits B 7 4 Electric strength test test voltage V MA Frestiorree phase mors M Operating voltage V sss Te wm ANNEX C TRANSFORMERS see 1 5 4 and 5 3 3 POS OM isis danse unes dan een been cula pese ciae No wire wound transformers providing insulation relied on for safety po B61 Bee B63 B64 B71 B72 B73 B74 B9 Bio
24. TNV3 to SELV are approved to UL CSA 60950 1and IEC 60384 14 and are certified by UL and Semko and are considered acceptable to lt gt gt z z z gt gt gt gt gt Mechanical actuators provide Basic insulation Humidity conditioning Only insulation relied upon for N A safety is the Y2 capacitor Humidity conditioning not relevant Relative humidity 96 temperature C m to ho 2 10 1 2 10 1 4 2 10 1 5 2 10 1 7 2 10 2 1 2 10 3 2 10 3 1 2 10 3 2 Page 12 of 45 Report Ref No 090 907721 000 Product Service Grade of insulation Model A200 Basic TNV3 to SELV Method s used tte Clearances creepage distances and distances through insulation 2 9 4 Separation from hazardous voltages No hazardous voltage on the board except for TNV3 circuit General Minimum Measurement Measured 1 68mm from pins 7 to 10 on J3 to confirm Basic Insulation provided btween TNV3 and SELV FFSQUENCY E Considered Pollution degrees sene PD2 Reduced values for functional insualtion N A Intervening unconnected conductive parts Intervening unconnected N A conductive parts not considered when determining creepage and clearances Insulation with varying dimensions No transformers providing required insualtion that effects safety Special separation requirements N A pulses N A A Cl
25. V 7 capacitors are required to building in Not connected directly be rated for the applicable line to line voltage to Mains 230 V 1 5 9 4 In Norway the third dashed sentence is No VDR s applicable only to equipment as defined in 6 1 2 2 of this annex 1 7 2 1 In Norway CLASS PLUGGABLE EQUIPMENT Class Ill equipment intended for TYPE A intended for connection to other building in Not connected directly equipment or a network shall if safety relies on to Mains connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts have a marking stating that the equipment must be connected to an earthed mains socket outlet The marking text in the applicable countries shall be as follows Apparatet ma tilkoples jordet stikkontakt 2 In Norway for requirements see 1 7 2 1 6 1 2 1 SELV circuits intended to be and 6 1 2 2 of this annex connected to SELV circuits only 2 In Norway there are additional requirements for Model A200 Bridging Y2 capacitors the insulation See 6 1 2 1 and 6 1 2 2 of this from TNV to SELV are approved to annex UL CSA 60950 1 and provide Basic insulation Tested at 1 5kV 2 In Norway for requirements see 1 7 2 1 6 1 2 1 Class IIl equipment intended for and 6 1 2 2 of this annex building in Not connected directly to Mains 5 8 2 4 3 2 3 4 annex 2 10 5 13 In Norway there are additional requirements for
26. a home or home office Pluggable Equipment Type A plug configuration are required to comply with additional requirements including markings instructions protection against inadvertent reactivation of a safety interlock disconnection from the mains supply via provision of an isolating switch and protection against operator access accessibility determined via new accessibility probe amp probe wedge Switzerland Ordinance on environmentally Equipment contains no mercury hazardous substance SR 814 81 Annex 1 7 Mercury Annex 1 7 of SR 814 81 applies for mercury Add the following NOTE In Switzerland switches containing mercury such as thermostats relays and level controllers are not allowed Switzerland Ordinance on chemical hazardous No batteries risk reduction SR 814 81 Annex 2 15 Batteries Annex 2 15 of SR 814 81 applies for batteries In Switzerland supply cords of equipment Class IIl equipment intended for having a RATED CURRENY not exceeding 10 A building in Not connected directly shall be provided with a plug complying with SEV to Mains 1011 or IEC 60884 1 and one of the following dimension sheets SEV 6532 2 1991 Plug Type 15 3P N PE 250 400 V 10 A SEV 6533 2 1991 Plug Type 11 L N 250 V 10A SEV 6534 2 1991 Plug Type 12 L N PE 250 V 10A In general EN 60309 applies for plugs for currents exceeding 10 A However a 16 A plug and socket outlet system is being introduced in Switzerla
27. connection N Overcurrent protection incorporated into No ringing signals generated equipment to provide power over telecommunication wiring system not interchangeable with devices of higher ratings if operator replaceable Additional requirements for equipment connected to a telecommunication network using cable subject to overvoltage from power line failures Where 26 AWG line cord required by Fig 6C Telecommunication cord provided either the cord is provided with the equipment or with equipment described in the safety instructions Equipment associated with the cable distribution Not intended for connection to Cable N system may need to be subjected to applicable Distribution Systems parts of Chapter 8 of the NEC lonizing radiation measurements made under Equipment does not produce ionizing single fault conditions according to 21 CFR 1020 radiation Continuous ringing signals evaluated to Method A No ringing signals generated subjected to special accessibility considerations Special requirements for message waiting and No ringing signals generated N similar telecommunications signals Equipment for use with a generic secondary Class III equipment intended for N protector marked with suitable instructions building in Not connected directly to Mains Equipment marked with suitable instructions if for Class IIl equipment intended for N use with a specific primary or secondary protector building in Not conn
28. less than 125 C Where the metal earth pin is replaced by an Insulated Shutter Opening Device ISOD the requirements of clauses 22 2 and 23 also apply In Ireland DIRECT PLUG IN EQUIPMENT is known as plug similar devices Such devices shall comply with Statutory Instrument 526 1997 National Standards Authority of Ireland Section 28 Electrical plugs plug similar devices and sockets for domestic use Regulations 1997 In Finland Norway and Sweden TOUCH CURRENT measurement results exceeding 3 5 mA r m s are permitted only for the following equipment STATIONARY PLUGGABLE EQUIPMENT TYPE A that is intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied for example in a telecommunication centre and has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON STATIONARY PLUGGABLE EQUIPMENT TYPE B STATIONARY PERMANENTLY CONNECTED EQUIPMENT Page 36 of 45 Report Ref No 090 907721 000 Product Service In Finland Norway and Sweden add the following text between the first and second paragraph of the compliance clause If this insulation is solid including insulation forming part of a component it shall at least consist of either two layers of thin sheet material each of which shall pass the electric strength test below or one layer having a distance through ins
29. normative Normative references to international publications with their corresponding European publications Annex ZB normative Special national conditions Annex ZC informative A deviations General Delete all the country notes in the reference document according to the following list 4 Note 2 1 5 1 Note 2 amp 3 1 5 7 1 Note 5 Note 2 1 5 9 4 Note 1 7 2 1 Note 4 5 amp 6 2 Note 2 2 4 Note 2 3 2 Note 3 2 1 Note 2 2 3 4 Note 2 2 6 3 3 Note 2 amp 3 we Note 2 10 3 2 Note 2 2 10 5 13 Note 3 2 1 1 Note 3 2 4 Note 3 2 5 1 Note 2 3 Note 1 amp 2 4 7 Note 4 4 7 2 2 Note 7 3 1 Note 2 5 1 7 1 Note 3 amp 4 3 Note 1 Note 2 amp 5 6 1 2 1 Note 2 1 2 Note Note 6 2 2 1 Note 2 2 2 Note Note 3 7 2 Note Note 1 amp 2 Note 2 AnnexH Note 2 National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 32 of 33 TV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark 1 3 21 Add the following subclause 1 8 21 Exposure to excessive sound pressure The apparatus shall be so designed and constructed as to present no danger when used for its intended purpose either in normal operating conditions or under fault conditions particularly providing protection against exposure to excessive sound pressures from headphones or earphones NOTE Z1 A new method of measurement is described in EN 50332 1 Sound system equipment
30. overvoltages N A on the cable distribution system Insulation between primary circuits and cable N A distribution systems Voltage surge test N A Impulse test N A Page 25 of 45 Report Ref No 090 907721 000 Product Service ANNEX A TESTS FOR RESISTANCE TO HEAT AND FIRE Flammability test for fire enclosures of movable Annex A not relied upon equipment having a total mass exceeding 18 kg and of stationary equipment see 4 7 3 2 E At SAMPISS MC T EE Wall thickness mm Conditioning of samples temperature C Eg Mounting of Te D O M Flame A B END EE EI Tepo M A18 Gomplange mem M oo Sample 1 burning time S Sample 2 burning time S i Sample 3 burning time S Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg and for material and components located inside fire enclosures see 4 7 3 2 and 4 7 3 4 Samples material pee BENE ii A21 Ls Wall thickness mm eeeeenenes p Res Conditioning of samples temperature C Mounting of ne Te ie TIE mE ET EEE WO Sample 1 burning time S Sample 2 burning time
31. 0 2008 06 Page 7 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark Annex Equipment that produces ionizing radiation is Equipment does not produce H required to comply with the Canadian Radiation ionizing radiation Emitting Devices Act REDR C1370 and or Code of Federal Regulations 21 CFR 1020 as applicable OTHER DIFFERENCES The following key national differences are based on requirements other than national regulatory requirements 1 5 1 Some components and materials associated Critical components are NRTL with the risk of fire electric shock or personal certified where required or have injury are required to have component or been evaluated as part of this material ratings in accordance with the investigation applicable national Canadian and or U S component or material standard requirements These components include attachment plugs battery packs rechargeable type used with transportable equipment cathode ray tubes circuit breakers communication circuit accessories connectors used for current interruption of non LPS circuits cord sets and power supply cords direct plug in equipment enclosures outdoor flexible cords and cables fuses branch circuit fuseholders ground fault current interrupters industrial control equipment insulating tape interconnecting cables lampholders li
32. 1 6 1 Introduction Class III product intended for N A building in Not directly connected to Mains V 2 TN power distribution systems Pa N A ANNEX W SUMMATION OF TOUCH CURRENTS Touch current from electronic circuits Class III product intended for N A building in Not directly connected to Mains gt So ik Page 30 of 45 Report Ref No 090 907721 000 Product Service wari Fomos M wiz femmes M w 2 Interconnection ot sovra equpments NA War emm M Common return comectedtoproteciveeanh ANNEX X MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS see clause E Determination of maximum input current No wire wound transformers providing insulation relied upon for safety i N N i D Co N A X 2 Overload test procedure ANNEX Y ULTRAVIOLET LIGHT CONDITIONING TEST see 4 3 13 3 Test apparatus sssssssssseeee Mounting of test samples sess Carbon arc light exposure apparatus Xenon arc light exposure apparatus ANNEX Z OVERVOLTAGE CATEGORIES see 2 10 3 2 and Clause G 2 ANNEX AA MANDREL TEST see 2 10 5 8 ANNEX BB CHANGES IN THE SECOND EDITION EN General 1 3 21 1 7 2 1 IW Product Service Page 31 of 45 Report Ref No 090 907721 000 EN 60950 1 2006 CENELEC COMMON MODIFICATIONS Add the following annexes Annex ZA normative Normative references to international public
33. 2 Attachment No 2 Product Service Model A101 Front External View Main Card Report Reference No 090 907721 000 Page 2 of 16 2009 11 12 Attachment No 2 amp Product Service Model A101 Rear External View Daughter Card Report Reference No 090 907721 000 Page 3 of 16 2009 11 12 Attachment No 2 Tw Product Service Model A101 Main Card Top Daughter Card Bottom Report Reference No 090 907721 000 Page 4 of 16 2009 11 12 Attachment No 2 Product Service Model A102 Front External View Main Card Report Reference No 090 907721 000 Page 5 of 16 2009 11 12 Attachment No 2 amp Product Service Model A102 Rear External View Daughter Card Report Reference No 090 907721 000 Page 6 of 16 2009 11 12 Attachment No 2 TW Product Service Model A102 Main Card Top Daughter Card Bottom THD Report Reference No 090 907721 000 Page 7 of 16 2009 11 12 Attachment No 2 Product Service Modei A104 Front External View Main Card Report Reference No 090 907721 000 Page 8 of 16 2009 11 12 Attachment No 2 TOV Product Service Model A104 Front External View Daughter Card Report Reference No 090 907721 000 Page 9 of 16 2009 11 12 Attachment No 2 TOV Product Service Model A104 Main Card Bottom Daughter Card Top
34. 3 apply to SELV circuits and accessible conductive parts Enamel coating on signal transformer winding wire allowed as an alternative to Basic insulation in specific telecommunication applications if subject to special construction requirements and testing Overcurrent protection device required for Class 2 and Class 3 limiting according to the NEC or for a Limited Power Source not interchangeable with devices of higher ratings if operator replaceable Equipment having receptacles for output a c power connectors generated from an internal separately derived source have the earthed grounded circuit conductor suitably bonded to For Pluggable Equipment Type A if a b or c are not applicable the current rating of the circuit is taken as 20A Capacity of connection between earthing terminal and parts required to be earthed subject to special conditions based on the current rating of the circuit Field wiring terminals for earthing conductors suitable for wire sizes gauge used in US Data for selection of special external branch circuit overcurrent devices marked on the equipment EE LE Model A200 Bridging Y2 capacitors from TNV to SELV are approved to UL CSA 60950 1 and provide Basic insulation Tested at 1 5kV Exception not relied upon No operator replaceable fuses No receptacles Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not co
35. 4 7 3 1 General Class III product intended for building in Not directly connected to Mains Fire enclosure to be provided in the end application 4 7 3 2 Materials for fire enclosures EE 4 7 2 B BIA B N NON D D a e AB l D ND P P N A N A N A N A N A N A N A Page 20 of 45 Report Ref No 090 907721 000 Product Service 4 7 3 3 Materials for components and other parts outside N A fire enclosures 4 7 3 4 Materials for components and other parts inside fire N A enclosures 4 7 3 5 Materials for air filler assemblies EN N A 4 7 3 6 Materials used in high voltage components EE N A Page 21 of 45 Report Ref No 090 907721 000 Product Service ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS Touch current and protective conductor current 5 1 1 General Class III product intended for building in Not directly connected to Mains Single fault testing only relevant in the end application Configuration of equipment under test EUT 5 1 2 1 Single connection to an a c mains supply 5 1 2 2 Redundant multiple connections to an a c mains supply Touch currents to telecommunication networks and cable distribution systems and from telecommunication networks Limitation of the touch current to a telecommunication network or to a cable distribution system 5 1 8 2 Summation of touch currents from telecommunication networks la EUT with earthed telecommunication ports
36. A For a d c mains supply NA Transients trom atelecommuricaton eme MA G 6 Determination of minimum clearances NA H ANNEX H IONIZING RADIATION see 4 3 13 N A ANNEX J TABLE OF ELECTROCHEMICAL POTENTIALS see 2 6 5 6 Page 28 of 45 Report Ref No 090 907721 000 Product Service Metal s used sse No protective earth Class III unit TNV compliance not reliant on enclosure grounding ANNEX K THERMAL CONTROLS see 1 5 3 and 5 3 8 Making and breaking capacity No thermal controls relied N A upon for safety 1 K 2 Thermostat reliability operating voltage V K 3 Thermostat endurance test operating voltage V Temperature limiter endurance operating voltage N A V i ANNEX L NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL BUSINESS EQUIPMENT see 1 2 2 1 and 4 5 2 Other business equipment Appropriate loading considered K K A T Z bina gt gt L ND ele gt gt gt rir jr OR gt r o 1 L 7 M ANNEX M CRITERIA FOR TELEPHONE RINGING SIGNALS see 2 3 1 Introduction No ringing signals produced Method A Method B M 3 1 Ringing signal M 3 1 1 Frequency Hz esee M 3 1 2 Voltage ma M 3 1 3 Cadence time s voltage V M 3 1 4 Single fault current mA sess T gt
37. A101 A102 A104 A108 A200 Series ePCI PCI Network Cards Analog Voice Card Digital Data and Voice Networking Cards fulfill the requirements of IEC 60950 1 2005 2 Edition During temperature tests the units were tested inside a desktop computer model Hewlett Packard a6030n while running looping software Model A102 test result is representative of A101 due to similar construction and considered worst case of the two models Model A108 test result is representative of A104 due to similar construction and considered worst case of the two models Tests performed name of test and test clause Testing location Equipment has undergone complete testing to T V PRODUCT SERVICE comply with IEC 60950 1 2005 2nd Edition 5 Cherry Hill Drive Danvers MA 01923 USA Summary of compliance with National Differences Refer to Attachment 1 All countries considered Copy of marking plate Class IIl product intended for building in Markings not required Page 3 of 45 Report Ref No 090 907721 000 Product Service Test item particulars Equipment mobility eene Intended for Building In Connection to the mains Not Directly Connected to the Mains Operating condition essseeeeeeees Continuous Access location Intended for Building In with Service Access Only in En
38. CB 1 03 06 Ref Certif No DE 3 58267 SYSTEME CEI D ACCEPTATION MUTUELLE DE CERTIFICATS D ESSAIS DES EQUIPEMENTS ELECTRIQUES IECEE METHODE OC IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT IECEE CB SCHEME CB TEST CERTIFICATE CERTIFICAT D ESSAI OC Product Produit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l usine Rating and principal characteristics Valeurs nominales et caract ristiques principales Trade mark if any Marque de fabrique si elle existe Model type Ref Ref de type Additional information if necessary Information compl mentaire si n cessaire sample of the product was tested and found to be in conformity with Un chantillon de ce produit a t essay et a t consid r conforme la as shown in the Test Report Ref No which form part of this certificate comme indiqu dans le Rapport d essais num ro de r f rence qui constitue une partie de ce certificat Information Technology Equipment ePCI PCI Network Cards Sangoma Technologies Inc 50 McIntosh Drive Suite 120 Markham ON L3R 9T3 CANADA Sangoma Technologies Inc 50 McIntosh Drive Suite 120 Markham ON L3R 913 CANADA Mara Technologies Inc 5680 14th Avenue Markham ON L3S 3K8 CANADA
39. EQUIPMENT provided with socket outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2 1a or DK 2 5a If poly phase equipment and single phase equipment having a RATED CURRENT exceeding 13 A is provided with a supply cord with a plug this plug shall be in accordance with the Heavy Current Regulations Section 107 2 D1 or EN 60309 2 In Spain supply cords of single phase equipment having a rated current not exceeding 10 A shall be provided with a plug according to UNE 20315 1994 Supply cords of single phase equipment having a rated current not exceeding 2 5 A shall be provided with a plug according to UNE EN 50075 1993 CLASS EQUIPMENT provided with socket outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard UNE 20315 1994 If poly phase equipment is provided with a supply cord with a plug this plug shall be in accordance with UNE EN 60309 2 In the United Kingdom apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to BS 1363 by means of that flexible cable or cord and plug shall be fitted with a standard plug in accordance with Statutory I
40. GGABLE EQUIPMENT TYPE B Page 38 of 45 Report Ref No 090 907721 000 Product Service M53 M53 1 TABLE List of critical components Object Part No Manufacturer Type Model Technical Data Standard Mark s Trademark Edition Year SU Fuse Inlet from RJ45 F1 F2 F3 F4 Ti Transformer T1 A101 series Littelfuse 461 Series 1 25A 600V UL 248 14 cURus F1250T Time Delay CSA C22 2 No 248 14 00 Pulse or PE 68678NL 1500Vrms UL 60950 1 UR Certified Isolation Equivalent 105 C Fuse Inlet from RJ45 F1 F2 F3 F4 F5 F6 F7 F8 T1 Transformer T1 T2 A102 series Littelfuse 461 Series 1 25A 600V UL 248 14 F1250T Time delay CSA C22 2 No 248 14 00 Pulse or PE 68678NL 1500Vrms UL 60950 1 UR Certified Isolation Equivalent 105 C Fuse inlet from RJ45 F2 F3 F4 F5 F6 F7 F8 F17 F18 F19 F20 F21 F22 F23 F24 A104 series Littelfuse 461 series 1 25A 600 V UL 248 14 F1250T time delay CSA C22 2 No 248 14 00 105 C Fuse Inlet from RJ45 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F14 F15 F16 F17 F18 F19 F20 F21 F22 F23 F24 F25 F26 F27 F28 F29 F30 F31 F32 A108 series Littelfuse 461 Series 1 25A 600V UL 248 14 F1250T Time Delay CSA C22 2 No 248 14 00 105 C Page 39 of 45 Report Ref No 090 907721 000 Product Service TABLE List of critical components Continued Object Part No M
41. II product intended for building in To be evaluated in end application 3 1 2 Protection against mechanical damage Ale Securing of internal wiring Insulation of conductors Po N A 3 1 5 3 1 6 Beads and ceramic insulators Screws for electrical contact pressure Insulating materials in electrical connections Self tapping and spaced thread screws PNA 3 2 Connection to a mains supply _ Means of connection Class III product intended for N A 3 1 8 3 1 9 3 1 10 building in To be evaluated in end application 3 2 1 1 Connection to an a c mains supply 3 2 1 2 Connection to a d c mains supply N A N A 3 2 2 Multiple supply connections N A 3 2 3 Permanently connected equipment N A Number of conductors diameter of cable and conduits mm N A N A N A 3 2 4 Appliance inlets 3 2 5 Power supply cords 3 2 5 1 AC power supply cords Rated current A cross sectional area mm um PANN Gy ER ae et 3252 _ DC power supply cords NA Cord anchorages and strain relief N A Mass of equipment kg pull N i Po e D ex Longitudinal displacement mm Protection against mechanical damage N A Diameter or minor dimension D mm test mass g Radius of curvature of cord mm e Page 16 of 45 Report Ref No 090 907721 000 Product Service Wiring termi
42. Rated Input Voltage 3 3V DC 5V DC Rated Input Current 1 7 A 1 5A Protection Class Hi see attachment for additional ratings and license conditions SANGOMA A101 Series see attachment for additional model information CBTL Procedure IEC 60950 1 2005 090 907721 000 This CB Test Certificate is issued by the National Certification Body Ce Certificat d essai OC est tabli par l Organisme National de Certification 2009 11 27 CB 09 11 72366 001 T V S D Product Service GmbH Certification Body Ridlerstrasse 65 D 80339 M nchen Joseph Janeliunas Product Service Page 1 of 2 CB 2 03 06 Ref Gertif No DE 3 58267 Additional Model and Rating information Rated Input Current Protection Class 1 7 1 5 A m Rated Input Voltage 2 3 VDC 5 VDC 3 3 V DC 5 V DC 1 7 A 1 5 A MI 3 3 V DC 5 V DC 1 7 A 1 5A I 1 7 A 15A n 1 7 1 5 A 0 7A m 3 3 V DC 5V DC 3 3 V DC 5 V DC 12 V DC License Conditions The unit is evaluated as component of other Information Technology Equipment where the suitability of each combination is to be determined by the accepting NCB Instructions and equipment markings related to safety shall be in a language which is acceptable in the country in which the equipment is to be insta
43. S II EQUIPMENT building in Not connected directly provided with a socket outlet in accordance with to Mains the Heavy Current Regulations Section 107 2 D1 Standard Sheet DK 1 4a CLASS II EQUIPMENT shall not be fitted with socket outlets for providing power to other equipment In Denmark supply cords of single phase Class IIl equipment intended for equipment having a rated current not building in Not connected directly exceeding13 A shall be provided with a plug to Mains according to the Heavy Current Regulations Section 107 2 D1 CLASS EQUIPMENT provided with socket outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2 1a or DK 2 5a If poly phase equipment and single phase equipment having a RATED CURRENT exceeding 13 A is provided with a supply cord with a plug this plug shall be in accordance with the Heavy Current Regulations Section 107 2 D1 or EN 60309 2 Denmark Heavy Current Regulations Chapter Class IIl equipment intended for 707 clause 707 4 building in Not connected directly TOUCH CURRENT measurement results to Mains exceeding 3 5 mA r m s are permitted only for PERMANENTLY CONNECTED EQUIPMENT and PLUGGABLE EQUIPMENT TYPE B National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 12 of 33 TOV Report Referen
44. STEM In the United Kingdom the current rating of the Class IIl equipment intended for circuit shall be taken as 13 A not 16 A building in Not connected directly to Mains In the United Kingdom to protect against Class IIl equipment intended for excessive currents and short circuits in the building in Not connected directly PRIMARY CIRCUIT of DIRECT PLUG IN to Mains EQUIPMENT tests according to 5 3 shall be conducted using an external protective device rated 30 A or 32 A If these tests fail suitable protective devices shall be included as integral parts of the DIRECT PLUG IN EQUIPMENT so that the requirements of 5 3 are met In the United Kingdom apparatus which is fitted Class IIl equipment intended for with a flexible cable or cord and is designed to be building in Not connected directly connected to a mains socket conforming to BS to Mains 1363 by means of that flexible cable or cord and plug shall be fitted with a standard plug in accordance with Statutory Instrument 1768 1994 The Plugs and Sockets etc Safety Regulations 1994 unless exempted by those regulations NOTE Standard plug is defined in SI 1768 1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug In the United Kingdom a power supply cord Class III equipment intended for with conductor of 1 25 mm2 is allowed for building in Not connected directly equipment with a rated current over
45. ame tele E i ATE Factory s name AANE PE Test specification Standard Test procedure Non standard test method Test Report Form No Test Report Form s Originator Master TRF esee 5 Cherry Hill Drive Danvers MA 01923 USA Sangoma Technologies Inc 50 McIntosh Dr Ste 120 Markham ON L3R 9T3 CANADA Sangoma Technologies Inc 50 McIntosh Dr Ste 120 Markham ON L3R 9T3 CANADA Mara Technologies 5680 14 Avenue Markham ON L3S 3K8 CANADA DX IEC 60950 1 2005 2nd Edition and or X EN 60950 1 2006 CB N A IECEN60950 1C SGS Fimko Ltd Dated 2007 06 Copyright 2007 IEC System for Conformity Testing and Certification of Electrical Equipment IECEE Geneva Switzerland All rights reserved This publication may be reproduced in whole or in part for non commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material IECEE takes no responsibility for and will not assume liability for damages resulting from the reader s interpretation of the reproduced material due to its placement and context If this Test Report Form is used by non IECEE members the IECEE IEC logo and the reference to the CB Scheme procedure shall be removed This report is not valid as a CB Test Report unless signed by an ap
46. anceller daughter card RSVLC XXXXX Where X can be any alphanumeric character OEM customer equivalent part number Page 5 of 45 Report Ref No 090 907721 000 Product Service GENERAL 1 Components Comply with IEC 60950 1 or relevant component Refer to appended table standard 1 5 1 Evaluation and testing of components Components not separately certified are used in accordance with their ratings and they comply with applicable parts of IEC EN 60950 and the relevant component Standard Thermal controls No thermal controls Eripe ceo RE Interconnecting cables No interconnecting cables N A Capacitors bridging insulation Model A200 Bridging Y2 capacitors from TNV3 to SELV are approved to UL CSA 60950 1and IEC 60384 14 and are certified by UL and Semko and are considered acceptable to provide Basic insulation 1 5 7 Resistors bridging insulation No such resistors 1 5 7 1 Resistors bridging functional basic or supplementary insulation 1 5 7 2 Resistors bridging double or reinforced insulation between a c mains and other circuits 1 5 7 3 Resistors bridging double or reinforced insulation between a c mains and antenna or coaxial cable 5 5 2 gt Z gt Components in equipment for IT power systems Class IIl product intended for building in Not directly connected to Mains 1 5 9 No surge suppressors 1 5 9 2 No such components 1 5 9 5 Bridging of supplementary double or reinforced in
47. anufacturer Type Model Technical Data Standard um Trademark Edition Year eU A200 series TNV to SELV Samtec MB1 130 01 F Clearance Connector J3 S 02 SL Creepage J21 1 68mm from Pins 7 to 10 minus Thickness of Pins 8 9 Alternate TNV Samtec MB1 130 01 F Clearance to SELV S 02 SL Creepage Connector J3 POLARIZED 2 4mm J21 Pin Position 8 9 12 13 18 19 22 23 Selectively Removed Daughter Card Sangoma FX0 5 Clearance FXO 5 Creepage 2 2mm from Pins Ring Tip to SELV Pins 7 to 10 Isolation Caps Murata GA342A1XGF3 250Vac UL 60950 1 UR Semko C24 C26 30JW31L 1500V Isolation IEC 60384 14 C38 C40 on Y2 the Analog Board FXO 5 UR PCB Material Various Various UL 94 V 0 Min UL 796 105 C Telecommunica Various Various Minimum No tion Line Cord 26AWG An asterisk indicates a mark which assures the agreed level of surveillance Supplementary information Components not certified to IEC standards have been evaluated during this investigation and found to be suitable for the application Page 40 of 45 D Report Ref No 090 907721 000 Product Service TABLE Electrical data in normal conditions L LL IL E Supplementary information Class IIl product intended for building in Measurements not required 2 10 3 and TABLE Clearance and creepage distance measurements 2 10 4 Clearance cl and creepage U peak Ur m s Required cl cl Required cr cr distance cr at of betwe
48. ate only to the object tested This report shall not be reproduced except in full without the written approval of the Issuing testing laboratory See Enclosure refers to additional information appended to the report See appended table refers to a table appended to the report Note This TRF includes EN Group Differences together with National Differences and Special National Conditions if any All Differences are located in the Appendix to the main body of this TRF Throughout this report a point is used as the decimal separator Page 4 of 45 Report Ref No 090 907721 000 Product Serice General product information The units are ePCI PCI cards intended to be installed in a desktop computer The unit is a class III device intended to be powered by a separately certified power supply The EUT model A200 is telephony card to be connected to a telecom network and is subjected to TNV 3 evaluation The A200 has two connectors for daughter cards FXO 5 and FXS to be inserted Only the FXO 5 is subjected to TNV 3 evaluation The daughter card FXS is not intended to be subjected to TNV 3 circuits Conditions of Acceptability T The unit is evaluated as a component of other Information Technology Equipment where the suitability of each combination is to be determined by the accepting NCB 2 Instructions and equipment markings related to safety shall be in a language which is acceptable in the country in which the eq
49. ation which demonstrate compliance with the applicable EU Directive are indicated in the OJEC Replace the last paragraph of this annex by At any point 10 cm from the surface of the OPERATOR ACCESS AREA the dose rate shall not exceed 1 uSv h 0 1 mR h see NOTE Account is taken of the background level Replace the notes as follows NOTE These values appear in Directive 96 29 Euratom Delete NOTE 2 Page 33 of 45 D Report Ref No 090 907721 000 Product Service Biblio Additional EN standards graphy ZA NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR CORRESPONDING EUROPEAN PUBLICATIONS Z SPECIAL NATIONAL CONDITIONS REFER TO ATTACHMENT 1 NATIONAL DEVIATIONS 1 2 4 1 In Denmark certain types of Class appliances see 3 2 1 1 may be provided with a plug not establishing earthing conditions when inserted into Danish socket outlets 1 5 7 1 In Finland Norway and Sweden resistors bridging BASIC INSULATION in CLASS PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in 1 5 7 2 In Norway due to the IT power system used see annex V Figure V 7 capacitors are required to be rated for the applicable line to line voltage 230 V 1 5 9 4 In Finland Norway and Sweden the third dashed sentence is applicable only to 1 equipment as defined in 6 1 2 2 of this annex 1 EQUIPMENT the socket outlet shall be in accordance with Standard Sheet DK 1 1b or DK 1 5a In Denmark socket outlets for pro
50. ations with their corresponding European publications Annex ZB normative Special national conditions Annex ZC informative A deviations Delete all the country notes in the reference document according to the following 1 5 1 Note 2 amp 3 Note Note Note 2 Note 2 Note 3 Note 4 Note 3 amp 4 Note 2 Note 2 1 5 7 1 1 7 2 1 2 3 2 2 6 3 3 2 10 5 13 2 5 1 4 7 2 2 5 3 7 6 1 2 2 6 2 2 2 7 3 Note Note 4 5 amp 6 Note Note 2 amp 3 Note 3 Note 2 Note Note 1 Note Note Note 1 amp 2 Note 2 Note 2 Note Note 2 Note Note Note 1 amp 2 Note 2 Note 2 amp 5 Note 6 Note 3 Note Note 2 AnnexH Note 2 Add the following subclause 1 3 21 Exposure to excessive sound pressure The apparatus shall be so designed and constructed as to present no danger when used for its intended purpose either in normal operating conditions or under fault conditions particularly providing protection against exposure to excessive sound pressures from headphones or earphones NOTE Z1 A new method of measurement is described in EN 50332 1 Sound system equipment Headphones and earphones associated with portable audio equipment Maximum sound pressure level measurement methodology and limit considerations Part 1 General method for one package equipment and in EN 50332 2 Sound system equipment Headphones and earphones associated with portable audio equipment Maximum sound pressure level measurement metho
51. ce No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark In Spain supply cords of single phase equipment Class IIl equipment intended for having a rated current not exceeding 10 A shall building in Not connected directly be provided with a plug according to UNE to Mains 20315 1994 Supply cords of single phase equipment having a rated current not exceeding 2 5 A shall be provided with a plug according to UNE EN 50075 1993 CLASS EQUIPMENT provided with socket outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard UNE 20315 1994 If poly phase equipment is provided with a supply cord with a plug this plug shall be in accordance with UNE EN 60309 2 Resistors bridging BASIC INSULATION in Class Ill equipment intended for CLASS PLUGGABLE EQUIPMENT TYPE A building in Not connected directly must comply with the requirements in 1 5 7 2 to Mains 1 5 9 4 The third dashed sentence is applicable only to No VDR s N equipment as defined in 6 1 2 2 of this annex 1 7 2 1 CLASS PLUGGABLE EQUIPMENT TYPE A Class III equipment intended for intended for connection to other equipment ora building in Not connected directly network shall if safety relies on connection to to Mains pro
52. computer room applications or 200 or less for other applications equivalent 5 1 8 2 Special earthing provisions and instructions for Class IIl equipment intended for N equipment with high touch current due to building in Not connected directly telecommunication network connections to Mains National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 30 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark equipment containing telecommunication network building in Not connected directly leads to Mains 5 3 7 N Overloading of SELV connectors and printed Equipment intended for building in wiring board receptacles accessible to the No SELV circuit connectors or operator printed wiring board connectors that are accessible to the operator repeated two additional times subject to certain conditions N Specialized instructions for telephones that may No telephones that may be be connected to a telecommunications network connected to a telecommunications network Marking identifying function of telecommunication Class Ill equipment intended for N type connectors not used for connection to a building in telecommunication network Equipment remotely powered over Class IIl equipment intended for N telecommunication wiring systems provided with building in specialized markings adjacent to the
53. ction performance and marking requirements are applicable to determine the adequacy of the slide rails support more than 9 kg Equipment complies with UL 1310 building in Not connected directly to Mains The max quantity of flammable liquid stored in equipment per ANSI NFPA 30 Table NAE 6 mm e ry al LEE indicate type of liquid to be used 4 3 13 2 Equipment that produces x radiation and does Equipment produces no X radiation not comply with 4 3 12 under all conditions of servicing marked to indicate the presence of radiation 4 3 13 5 Requirements contained in the applicable No lasers national codes apply to lasers 21 CFR 1040 Automated information storage equipment Not an automated information intended to contain more than 0 76 m of storage system combustible media requires provision for automatic sprinklers or a gaseous agent extinguishing system Equipment for use in environmental air space N other than ducts or plenums provided with metal enclosure or with non metallic enclosure having adequate fire resistance and low smoke producing characteristics according to UL 2043 Equipment for installation in space used for environmental air described in Sec 300 22 c of the NEC provided with instructions indicating suitability for installation Flame spread rating for external surface of N combustible material with exposed area greater than 0 93 m or a single dimension greater than 1 8 m 50 or less for
54. d Product Over voltage category OVC sess OVCI Mains supply tolerance 96 or absolute mains supply VAN OS ei ac cence ttle E E OT E N A Intended for Building In Tested for IT power systems esseere N A Intended for Building In IT testing phase phase voltage V N A Intended for Building In Class of equipment sssssseeeees Class III Considered current rating A ssssssss Models A101 A102 A104 A108 3 3Vdc 1 7A 5Vdc 1 5A Model A200 3 3Vdc 1 7A 5Vdc 1 5A 12Vdc 0 7A Pollution degree PD esses PD2 IP Protection Class 248 eene IPX0 Altitude during operation m s Rated up to 3050m Altitude of test laboratory m sssssss 200m Mass of equipment kg eeeeeess 0 1 kg Possible test case verdicts test case does not apply to the test object N A test object does meet the requirement P Pass test object does not meet the requirement F Fail Testing ooi gne ene o gato ensi etit Date of receipt of test item essssssuss 2009 10 13 Date s of performance of tests ssss 2009 10 15 to 2009 10 23 General remarks The test results presented in this report rel
55. del A102 test result is representative of A101 due to similar construction and considered worst case of the two models Model A108 test result is representative of A104 due to similar construction and considered worst case of the two models T C Allowed Insulation le ae class RE RN nl l Le D DNE NN nn Supplementary information Rise of Resistance method not utilized e Page 44 of 45 Report Ref No 090 907721 000 Product Service TABLE Ball pressure test of thermoplastic parts Allowed impression diameter mm lt 2 mm C Supplementary information No thermoplastic part supporting hazardous voltages Impression diameter mm 14 7 TABLE Resistance to fire Manufacturer of Type of material Thickness Flammability Evidence aE mm EE Supplementary information Class Ill product intended for building in To be evaluated in the end appliction TABLE Electric strength tests impulse tests and voltage surge tests P Test voltage applied between Voltage shape Test voltage Breakdown AC DC Yes No impulse surge Functional Basic supplementary Model A200 TNV3 to Enclosure 2121 No Model A200 TNV3 to SELV 2121 No Reinforced Impulse Model A200 TNV3 to Enclosure 1500 No Model A200 TNV3 to SELV 1500 No Supplementary information Test voltage for Australian deviations Impulse Test conducted as per Clause 6 2 2 10 700uS impusle gene
56. dology and limit considerations Part 2 Guidelines to associate sets with headphones coming from different manufacturers Add the following NOTE NOTE Z1 The use of certain substances in electrical and electronic equipment is restricted within the EU see Directive 2002 95 EC Add the following NOTE NOTE Z1 In addition the instructions shall include as far as applicable a warning that excessive sound pressure from earphones and headphones can cause hearing loss This subclause has been declared void 3 2 3 Delete the NOTE in Table 3A and delete also in this table the conduit sizes in parentheses Replace 60245 IEC 53 by H05 RR F 60227 IEC 52 by H03 VV F or H03 VVH2 F 60227 IEC 53 by H05 VV F or H05 VVH2 F2 In Table 3B replace the first four lines by the following 3 2 5 1 4 3 13 6 Page 32 of 45 Report Ref No 090 907721 000 Product Service Replace the subclause as follows Basic requirements To protect against excessive current short circuits and earth faults in PRIMARY CIRCUITS protective devices shall be included either as integral parts of the equipment or as parts of the building installation subject to the following a b and C a except as detailed in b and c protective devices necessary to comply with the requirements of 5 3 shall be included as parts of the equipment b for components in series with the mains input to the equipment such as the supply cord appl
57. earances Minimum Measurement Measured 1 68mm from pins 7 to 10 on J3 to confirm Basic Insulation provided btween TNV3 and SELV Mains transient voltages Class III product intended for building in Not directly connected to Mains N gt a AC mains supply sseeeeeee b Earthed d c mains supplies Unearthed d c mains supplies gt gt d Battery operation gt Clearances in primary circuits Class IIl product intended for building in Not directly connected to Mains Page 13 of 45 Report Ref No 090 907721 000 Product Service Clearances in secondary circuits Class III product intended for building in Not directly connected to Mains 2 10 3 5 Clearances in circuits having starting pulses No staring pulses 2 10 3 6 Transients from a c mains supply Class III product intended for building in Not directly connected to Mains Transients from d c mains supply Class IIl product intended for building in Not directly connected to Mains Transients from telecommunication networks and Considered N A cable distribution systems Measurement of transient voltage levels Class III product intended for N A building in Not directly connected to Mains 8 Transient
58. ected directly to Mains National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 31 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark NAD Acoustic pressure from an ear piece for short and No earpieces provided long duration disturbances NAD N Equipment connected to a telecommunication No earpieces provided and cable distribution networks and supplied with an earphone intended to be held against or in the ear is required to comply with special acoustic pressure requirements Household Home Office Document Shredders Not a shredder N AF 1 7 Markings and instructions alert the user to key safety considerations related to use of shredders including not intended to be used by children avoid touching document feed opening avoid clothes and hair entanglement and avoid aerosol products NAF 1 NAF 2 8 Safety interlock cannot be inadvertently activated 3 by the articulated accessibility probe SS appropriate markings associated with the switch NAF 4 4 Hazardous moving parts are not accessible as determined using the articulated accessibility AF 3 4 Provided with an isolating switch complying with 3 4 2 including 3 mm contact gap with probe and the accessibility probe wedge EN 60950 1 2006 COMMON MODIFICATIONS Contents Add the following annexes Annex ZA
59. en V V mm mm mm mm Functional Supplementary information e Measured from connector J3 pins 7 10 minus the thickness of pins 8 9 e clearance requirement for rating of 3050m altitude Page 41 of 45 Report Ref No 090 907721 000 Product Service 2 10 5 TABLE Distance through insulation measurements Distance through insulation DTI at of U peak U rms Test Required DTI V V voltage mm V Supplementary information No reliance on Distance Through Insulation TABLE Batteries The tests of 4 3 8 are applicable only when appropriate battery data is not available Is it possible to install the battery in a reverse polarity position Non rechargeable batteries Rechargeable batteries Discharging Un Charging Discharging Reversed intentional charging Meas Manuf Charging Meas Manuf Meas Manuf Meas Manuf Current Specs Current Specs Current Specs Current Specs Max current during normal condition Max current during fault condition Test results Verdict Chemical leaks Explosion of the battery Emission of flame or expulsion of molten metal Electric strength tests of equipment after completion of tests Supplementary information No batteries Page 42 of 45 Report Ref No 090 907721 000 Product Service C rat Allowed Tmax C ature T of part at T C E3 Model A102 CCE AFT Base POB near UP 360
60. en the exclusions are applicable for PERMANENTLY CONNECTED EQUIPMENT PLUGGABLE EQUIPMENT TYPE B and equipment intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied e g in a telecommunication centre and which has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON In Finland Norway and Sweden for requirements see 6 1 2 1 and 6 1 2 2 of this The term TELECOMMUNICATION NETWORK in 6 1 2 being replaced by the term CABLE DISTRIBUTION SYSTEM In Norway and Sweden there are many buildings where the screen of the coaxial cable is normally not connected to the earth in the building installation Add the following NOTE In Sweden switches containing mercury are not permitted Page 37 of 45 Report Ref No 090 907721 000 Product Service Switzerland Ordinance on environmentally hazardous substances SR 814 081 Annex 1 7 Mercury Annex 1 7 of SR 814 81 applies for mercury Add the following NOTE In Switzerland switches containing mercury such as thermostats relays and level controllers are not allowed Denmark Heavy Current Regulations Supply cords of CLASS EQUIPMENT which is delivered without a plug must be provided with a visible tag with the following text Vigtigt Lederen med gren gul isolation ma kun tilsluttes en kemme m rket eller If essential for the sa
61. ent force N Class III product intended for N A building in Design and construction IN D o AB D O A D x o Edges and corners All edges and corners are P judged to be sufficiently well rounded so as not to constitute a hazard Handles and manual controls force N PE N A Adjustable controls No adjustable controls N A Securing of parts The equipment does not have N A any supplementary or reinforced insulation sels NE Go o o o to AJOJN A Co e Connection by plugs and sockets The equipment does not have N A any interchangeable plugs sockets 4 3 6 Direct plug in equipment Not direct plug in equipment N A N A 4 3 7 Heating elements in earthed equipment The equipment does not have N A any heating elements any batteries e Page 18 of 45 Report Ref No 090 907721 000 Product Service Overcharging of a rechargeable battery Unintentional charging of a non rechargeable battery Reverse charging of a rechargeable battery Excessive discharging rate for any battery Oil and grease Not intended to be exposed to oil grease or similar Dust powders liquids and gases The equipment does not produce dust or employ powders liquids or gases Containers for liquids or gases The equipment does not contain liquids The equipment does not use any flammable liquids 4 3 9 Flammable liquids
62. et The marking text in the applicable countries shall be as follows In Finland Laite on liitett v suojamaadoituskoskettimilla varustettuun pistorasiaan In Norway Apparatet m tilkoples jordet stikkontakt In Sweden Apparaten skall anslutas till jordat uttag insulation see 6 1 2 1 and 6 1 2 2 of this annex 3 2 1 1 3 2 1 1 3 2 1 1 3 2 1 1 3 2 1 1 In Switzerland for requirements see 3 2 1 1 of this annex 3 2 5 1 Page 34 of 45 Report Ref No 090 907721 000 Product Service In Switzerland supply cords of equipment having a RATED CURRENT not exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC 60884 1 and one of the following dimension sheets SEV 6532 2 1991 Plug Type 15 3P4N PE 250 400 V 10 A SEV 6533 2 1991 Plug Type 11 L N 250 V 10A SEV 6534 2 1991 Plug Type 12 L N PE 250V 10A In general EN 60309 applies for plugs for currents exceeding 10 A However a 16 A plug and socket outlet system is being introduced in Switzerland the plugs of which are according to the following dimension sheets published in February 1998 SEV 5932 2 1998 Plug Type 25 3L N PE 230 400 V 16 A SEV 5933 2 1998 Plug Type 21 L N 250 V 16A SEV 5934 2 1998 Plug Type 23 L N PE 250V 16A In Denmark supply cords of single phase equipment having a rated current not exceeding13 A shall be provided with a plug according to the Heavy Current Regulations Section 107 2 D1 CLASS
63. fety of the equipment the tag must in addition be provided with a diagram which shows the connection of the other conductors or be provided with the following text For tilslutning af de vrige ledere se medf lgende installationsvejledning Germany Gesetz ber technische Arbeitsmittel und Verbraucherprodukte Ger te und Produktsicherheitsgesetz GPSG Law on technical labour equipment and consumer products of 6th January 2004 Section 2 Article 4 Clause 4 Item 2 If for the assurance of safety and health certain rules during use amending or maintenance of a technical labour equipment or readymade consumer product are to be followed a manual in German language has to be delivered when placing the product on the market Of this requirement rules for use even only by SERVICE PERSONS are not exempted Denmark Heavy Current Regulations With the exception of CLASS Il EQUIPMENT provided with a socket outlet in accordance with the Heavy Current Regulations Section 107 2 D1 Standard Sheet DK 1 4a CLASS Il EQUIPMENT shall not be fitted with socket outlets for providing power to other equipment Switzerland Ordinance on chemical hazardous risk reduction SR 814 81 Annex 2 15 Batteries Annex 2 15 of SR 814 81 applies for batteries Denmark Heavy Current Regulations Chapter 707 clause 707 4 TOUCH CURRENT measurement results exceeding 3 5 mA r m s are permitted only for PERMANENTLY CONNECTED EQUIPMENT and PLU
64. iance coupler r f i filter and switch short circuit and earth fault protection may be provided by protective devices in the building installation C it is permitted for PLUGGABLE EQUIPMENT TYPE B or PERMANENTLY CONNECTED EQUIPMENT to rely on dedicated overcurrent and short circuit protection in the building installation provided that the means of protection e g fuses or circuit breakers is fully specified in the installation instructions If reliance is placed on protection in the building installation the installation instructions shall so state except that for PLUGGABLE EQUIPMENT TYPE A the building installation shall be regarded as providing protection in accordance with the rating of the wall socket outlet Up to and including 6 0 75 9 Over 6 up to and including 10 0 75 b 1 0 Over 10 up to and including 16 1 0 e 1 5 In the conditions applicable to Table 3B delete the words in some countries in condition In NOTE 1 applicable to Table 3B delete the second sentence In Table 3D delete the fourth line conductor sizes for 10 to 13 A and replace with the following Over 10 up to and including 16 1 5 to 2 5 1 5 to 4 Delete the fifth line conductor sizes for 13 to 16 A Add the following NOTE NOTE Z1 Attention is drawn to 1999 519 EC Council Recommendation on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz Standards taking into account this Recommend
65. in substances in electrical and electronic equipment is restricted within C it is permitted for PLUGGABLE EQUIPMENT TYPE B or PERMANENTLY CONNECTED EQUIPMENT to rely on dedicated overcurrent and short circuit protection in the building installation provided that the means of protection e g fuses or circuit breakers is fully specified in the installation instructions If reliance is placed on protection in the building installation the installation instructions shall so state except that for PLUGGABLE EQUIPMENT TYPE A the building installation shall be regarded as providing protection in accordance with the rating of the wall socket outlet This subclause has been declared void 1 5 1 2 7 1 2 7 2 3 2 3 Delete the NOTE in Table 3A and delete also in this table the conduit sizes in N parentheses National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 33 of 33 uv Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark 3 2 5 1 Replace 60245 IEC 53 by H05 RR F 60227 IEC 52 by H03 VV F or H03 VVH2 F 60227 IEC 53 by H05 VV F or H05 VVH2 F2 In Table 3B replace the first four lines by the following Up to and including 6 0 759 Over 6 up to and including 10 0 75 9 1 0 Over 10 up to and including 16 1 0 9 1 5 n the conditions applicable to Table 3B delete the words i
66. ined in EN 60950 1 2006 6 2 2 1 the additional testing shall be performed on all the test specimens as described in EN 132400 the impulse test of 2 5 kV is to be performed before the endurance test in EN 132400 in the sequence of tests as described in EN 132400 National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 20 of 33 TV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark In Norway the exclusions are applicable for Class Ill equipment intended for PERMANENTLY CONNECTED EQUIPMENT building in Not connected directly PLUGGABLE EQUIPMENT TYPE B and to Mains equipment intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied e g in a telecommunication centre and which has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON In Norway for requirements see 6 1 2 1 and Not intended for connection to Cable 6 1 2 2 of this annex Distribution Systems The term TELECOMMUNICATION NETWORK in 6 1 2 being replaced by the term CABLE DISTRIBUTION SYSTEM In Norway there are many buildings where the Not intended for connection to Cable screen of the coaxial cable is normally not Distribution Systems connected to the earth in the building installation
67. ing conductors protective bonding conductors 2 6 5 5 Parts removed during servicing 2 6 5 7 Screws for protective bonding N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A e Page 11 of 45 Report Ref No 090 907721 000 Product Service 2 6 5 8 Reliance on telecommunication network or cable N A distribution system 2 7 Overcurrent and earth fault protection in primary circuits 2 7 1 Basic requirements Class III product intended for N A building in Not directly connected to Mains Instructions when protection relies on building N A installation Faults not simulated in 5 3 7 EE N A Short circuit backup protection N A 2 7 4 Number and location of protective devices Protection by several devices 2 7 6 gt Warning to service personnel 2 8 Safety interlocks 2 8 1 General principles No safety interlocks provided N A or required 2 8 2 Protection requirements 2 8 3 Inadvertent reactivation 2 8 4 Fail safe operation gt zziz gt gt gt 2 8 5 Moving parts 2 8 7 Switches and relays 2 8 7 1 Contact gaps mm sssssseeeeee 2 8 7 2 Overload test 2 8 7 3 Endurance test 2 8 7 4 Electric strength test 2 8 8 2 9 Electrical insulation 2 9 1 Properties of insulating materials Model A200 Bridging Y2 P capacitors from
68. irectly supply circuit to the equipment earthing conductor tg Mains National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 27 of 33 Report Reference No 090 907721 000 Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Special markings and instructions for equipment with earthed conductor of a DC supply circuit connected to the equipment earthing conductor Terminals and leads provided for permanent connection of DC powered equipment to supply marked to indicate polarity if reverse polarity may result in a hazard Permanently connected equipment has provision for connecting and securing a field wiring system i e conduit or leads etc per the NEC Permanently connected equipment may have terminals or leads not smaller than No 18 AWG 0 82 mm and not less than 150 mm in length for connection of field installed wiring If supply wires exceed 60 C marking indicates use of 75 C or 90 C wiring for supply connection as appropriate Equipment compatible with suitable trade sizes of conduits and cables Length of power supply cord limited to between 1 5 and 4 5 m unless shorter length used when intended for a special installation Conductors in power supply cords sized per NEC Power supply cords and cord sets incorporate flexible cords suitable for the particular application Strain relief provided for non detachable interconnecting cables not supplied by a limited power source
69. ke 1 5 5 For other than limited power and TNV circuits the N type of output circuit identified for output connector m iem e length to be types specified in the NEC 1 5 5 Detachable external interconnecting cables 3 05 N m or less in length and provided with equipment marked to identify the responsible organization and the designation for the cable 1 Building wiring and cable for use in ducts plenums and other air handling space subject to special requirements and excluded from scope kaai o a LL comply with UL 1863 1 6 1 2 Equipment intended for connection to a d c Class IIl equipment intended for power mains distribution system subjected to building in Not connected directly special circuit classification requirements e g to Mains TNV 2 1 1 6 1 2 Earthing of d c powered equipment provided DIDI Lamp replacement information indicated on No lamps lampholder in operator access area Pr Equipment voltage rating not higher than rating of D the plug except under special conditions feel Fuse replacement marking for operator accessible fuses Identification of terminal connection of the Class III equipment intended for equipment earthing conductor building in Not connected directly to Mains 1 1 1 1 Connectors and field wiring terminals for external Class III equipment intended for Class 2 or Class 3 circuits provided with marking building in Not connected directly indicating minimum Class of wiri
70. lding in Not connected directly for use outside of computer room and provided to Mains with such instructions Equipment in wire line communication facilities Class Ill equipment intended for serving high voltage electric power stations building in Not connected directly operating at greater than 1kV are excluded to Mains Equipment intended for outdoor use Class Ill equipment intended for building in Not connected directly to Mains in the installation is assumed to be 20 A All IEC standards for components identified in Critical components are NRTL Annex P 1 replaced by the relevant requirements certified where required or have M of UL component standards in Annex P 1 been evaluated as part of this investigation 1 5 1 All IEC standards for components identified in Critical components are NRTL Annex P 2 alternatively satisfied by the relevant certified where required or have requirements of UL component standards been evaluated as part of this investigation National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 24 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark Interconnecting cables acceptable for the Class Ill equipment intended for application regarding voltage current building in No interconnect cables temperature flammability mechanical provided serviceability and the li
71. lled A suitable fire electrical mechanical enclosure shall be provided in the end system application 4 Minimum no 26AWG telecommunication line cord is supplied with the equipment The EUT models A101 A102 A104 and A108 are digital data and voice network cards They are not subjected to TNV evaluation as an approved TELCO provided DMARK device providing isolation from the TNV to the EUT must be provided in the end use application The EUT are rated for a maximum ambient temperature of 50 C Date 2009 11 27 3 CB 09 11 72366 001 Joseph Janeliunas Product Service T V S D Product Service GmbH Certification Body Ridlerstrasse 65 D 80339 M nchen Page 2 of 2 e Product Service Page 1 of 45 Report Ref No 090 907721 000 Test Report issued under the responsibility of NCB T V S D Product Service GmbH Ridlerstr 65 D 80339 M nchen Germany Product Service TEST REPORT IEC 60950 1 2005 2nd Edition and or EN 60950 1 2006 Information technology equipment Safety Part 1 General requirements Report Reference No 090 907721 000 Date of issue 2009 11 12 Total number of pages 44 Pages CB CCA Testing Laboratory T V PRODUCT SERVICE Address el ER Applicant s name Address toe ease ant Manufacturer s n
72. mit controls printed wiring protectors for communications circuits receptacles solid state controls supplementary protectors switches including interlock switches thermal cutoffs thermostats multi layer transformer winding wire transient voltage surge suppressors tubing wire connectors and wire and cables A circuit for connection to the DC Mains Supply Class IIl equipment intended for is classified as either a SELV Circuit TNV 2 building in Not connected directly Circuit or Hazardous Voltage Circuit depending to Mains Approved power supply to on the maximum operating voltage of the be provided at the end installation supply This maximum operating voltage shall include consideration of the battery charging float voltage associated with the intended supply system regardless of the marked power rating of the equipment For TNV 2 and TNV 3 circuits with other than Model A200 TNV 3 No ringing ringing signals and with voltages exceeding 42 4 signals generated Vpeak or 60 Vd c the maximum acceptable current through a 2000 ohm resistor or greater connected across the voltage source with other loads disconnected is 7 1 mA peak or 30 mA d c under normal operating conditions National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 8 of 33 uv Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result
73. n some countries in condition a In NOTE 1 applicable to Table 3B delete the second sentence 3 3 4 In Table 3D delete the fourth line conductor sizes for 10 to 13 A and replace with the following Over 10 up to and including 16 1 5 to 2 5 1 5to4 Delete the fifth line conductor sizes for 13 to 16 A 4 3 13 6 Addthe following NOTE NOTE Z1 Attention is drawn to 1999 519 EC Council Recommendation on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz Standards taking into account this Recommendation which demonstrate compliance with the applicable EU Directive are indicated in the OJEC Ann Replace the last paragraph of this annex by At any point 10 cm from the surface of the OPERATOR ACCESS AREA the dose rate shall not exceed 1 uSv h 0 1 mR h see NOTE Account is taken of the background level Replace the notes as follows NOTE These values appear in Directive 96 29 Euratom Delete NOTE 2 Additional EN standards NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR CORRESPONDING EUROPEAN PUBLICATIONS SPECIAL NATIONAL CONDITIONS SEE INDIVIDUAL COUNTRIES A DEVIATIONS informative SEE INDIVIDUAL COUNTRIES National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Product Service Attachment No 2 PHOTOGRAPHS Attachment Contains Total 16 Pages Cover page 1 Page Photos 15 Pages Report Reference No 090 907721 000 Page 1 of 16 2009 11 1
74. nals for connection of external conductors 3 3 1 Wiring terminals Class III product intended for N A building in To be evaluated in end application Connection of non detachable power supply cords NENNEN N A Conductor sizes to be connected EN N A Rated current A cord cable type cross sectional area m m EET 3 3 5 Wiring terminal sizes a N A Rated current A type nominal thread diameter du RT Wiring terminal design N A Disconnection from the mains supply 3 4 1 General requirement Class III product intended for N A building in To be evaluated in end application 34 41 Multiple power sources EN N A Interconnection of equipment Types of interconnection circuits N A PHYSICAL REQUIREMENTS Page 17 of 45 Report Ref No 090 907721 000 Product Service Stability Test force N 222 vtr Angle of 10 Class III product intended for N A building in 0000 CENA RB D Mechanical strength General Class III product intended for N A building in To be evaluated in end application AR D Steady force test 10 N AR D ND Steady force test 30 N N A Steady force test 250 N N A Faltest M wee OO O OOo m Drop test height mm eeseeeesess PNA Picture tube separately certified PN Wall or ceiling mounted equipm
75. nd the plugs of which are according to the following dimension sheets published in February 1998 SEV 5932 2 1998 Plug Type 25 3L N PE 230 240 V 16 A SEV 5933 2 1998 Plug Type 21 L N 250 V 16A SEV 5934 2 1998 Plug Type 23 L N PE 250 V 16A National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 10 of 33 uv Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark In Switzerland for requirements see 3 2 1 1 of Class Ill equipment intended for this annex building in Not connected directly to Mains Germany Gesetz ber technische Arbeitsmittel Instructions to be provided in the und Verbraucherprodukte Gerate und appropriate language of the Produktsicherheitsgesetz GPSG Law on destination country technical labour equipment and consumer products of 6th January 2004 Section 2 Article 4 Clause 4 Item 2 If for the assurance of safety and health certain rules during use amending or maintenance of a technical labour equipment or readymade consumer product are to be followed a manual in German language has to be delivered when placing the product on the market Of this requirement rules for use even only by SERVICE PERSONS are not exempted In Denmark certain types of Class appliances Class Ill equipment intended for see 3 2 1 1 may be provided with a plug not building in Not co
76. nder stress Supplemetary reinforced insulation MAT Construction of printed boards Separately approved PCB provided Uncoated printed boards 2 10 6 2 10 6 1 2 10 6 2 2 10 6 3 Coated printed boards Insulation between conductors on the same inner surface of a printed board 2 10 6 4 Insulation between conductors on different layers of a printed board Distance through insulation Number of insulation layers pcs o NA Component external terminations No coatings relied upon for increased creepage and clearance Tests on coated printed boards and coated Separately approved PCB components provided Testing not required 2 10 8 1 2 10 8 2 2 10 8 3 2 10 8 4 2 10 9 Sample preparation and preliminary inspection Electric strength test Abrasion resistance test Thermal cycling Thermal cycling not relied upon Test for Pollution Degree 1 environment and PD2 with no reliance on insulating compound insulating compounds Tests for semiconductor devices and cemented DJ joints 2 10 10 2 10 11 N A N A N A N A N A N A N A N A N A N A N A N A N A N A A 2 10 12 Enclosed and sealed parts Page 15 of 45 Report Ref No 090 907721 000 Product Service Co oo olo w o uH a EN ne DE N io A WIRING CONNECTIONS AND SUPPLY General Z gt Current rating and overcurrent protection Class I
77. ng to be used to Mains 1 Marking located adjacent to terminals and visible Class III equipment intended for during wiring building in Not connected directly to Mains 5 5 5 5 7 ol 7 6 7 7 7 7 7 7 2 1 1 1 Bare TNV conductive parts protected by a cover Class III equipment intended for are exempt if instructions include directions for building in disconnection of TNV prior to removal of the cover 1 7 1 Special marking format for equipment intended Class III equipment intended for for use on a supply system with an earthed building in Not connected directly neutral and more than one phase conductor to Mains National Differences IEC 60950 1 2nd ed Rev 00 2008 06 2 3 1 b 2 3 2 1 2 7 1 Page 25 of 33 Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark 2 3 1 b Other telecommunication signaling systems than No ringing signals generated described in 2 3 1 b are subject to M 4 For TNV 2 and TNV 3 circuits with other than ringing signals and with voltages exceeding 42 4 Vp or 60 V d c the max current limit through a resistor 2 2000 Ohm with loads disconnected is 7 1 mA peak or 30 mA d c under normal conditions Limits for measurements across 5000 Ohm resistor in the event of a single fault are replaced after 200 ms with the limits of M 3 1 4 For a single fault the limits of 2 2
78. nnected directly establishing earthing conditions when inserted to Mains into Danish socket outlets Denmark Heavy Current Regulations Class Ill equipment intended for Supply cords of CLASS EQUIPMENT which is c Not connected directly delivered without a plug must be provided with a 9 Vans visible tag with the following text Vigtigt Lederen med gren gul isolation ma kun tilsluttes en kemme m rket eller If essential for the safety of the equipment the tag must in addition be provided with a diagram which shows the connection of the other conductors or be provided with the following text For tilslutning af de vrige ledere se medf lgende installationsvejledning National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 11 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark In Denmark socket outlets for providing power to Class IIl equipment intended for other equipment shall be in accordance with the building in Not connected directly Heavy Current Regulations Section 107 2 D1 to Mains Standard Sheet DK 1 3a DK 1 5a or DK 1 7a when used on Class equipment For STATIONARY EQUIPMENT the socket outlet shall be in accordance with Standard Sheet DK 1 1b or DK 1 5a Denmark Heavy Current Regulations Class Ill equipment intended for With the exception of CLAS
79. nnected directly to Mains Class IIl equipment intended for building in No field wiring connections Class IIl equipment intended for building in Not connected directly to Mains Standard supply outlets protected by overcurrent No outlets N device in accordance with the NEC National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 26 of 33 TV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark that distribute power to other units over branch power circuit wiring PT e e TN apply to equipment provided with panelboards Non motor operated equipment requiring special Class III equipment intended for overcurrent protective device marked with device puyilding in Not connected directly rating to Mains 2 10 5 12 Multi layer winding wire subject to UL component No such windings wire requirements in addition to 2 10 5 12 and Annex U Permissible combinations of internal Class III equipment intended for wiring external cable sizes for overcurrent amp short building in Not connected directly circuit protection to Mains 3 1 1 All interconnecting cables protected against No interconnecting cables N overcurrent and short circuit Wiring methods permit connection of equipment Class III equipment intended for to primary power supply in accordance with the building in Not connected directly NEC to
80. nnection to terminal for equipment earthing building in Not connected directly conductor to Mains Field wiring connections made through the use of Class III equipment intended for suitable pressure connectors including set screw building in Not connected directly type solder lugs or splices to flexible leads to Mains Separate motor control device s required for No motors cord connected equipment rated more than 12 A or with motor rated more than 1 3 hp or more than 120 V SO Up position of handle is on devices 3 4 11 For computer room applications equipment with No batteries battery systems capable of supplying 750 VA for 5 minutes provided with battery disconnect means Special opening restrictions for enclosures around CRTs with face dimension of 160 mm or more Compartment housing high pressure lamp marked to indicate risk of explosion Aluminum conductors not permitted for Class III equipment intended for National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 29 of 33 TV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark For equipment mounted on racks and provided Class IIl equipment intended for with slide rails allowing the equipment to slide building in Not connected directly away from the rack for installation and to Mains Not directly rack mounted maintenance additional constru
81. nstrument 1768 1994 The Plugs and Sockets etc Safety Regulations 1994 unless exempted by those regulations NOTE Standard plug is defined in SI 1768 1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug In Ireland apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to I S 411 by means of that flexible cable or cord and plug shall be fitted with a 13 A plug in accordance with Statutory Instrument 525 1997 National Standards Authority of Ireland section 28 13 A Plugs and Conversion Adaptors for Domestic Use Regulations 1997 In the United Kingdom a power supply cord with conductor of 1 25 mm2 is allowed for equipment with a rated current over 10 A and up to and including 13 A In the United Kingdom the range of conductor sizes of flexible cords to be accepted by terminals for equipment with a RATED CURRENT of over 10 A up to and including 13 A is 1 25 mm to 1 5 mm nominal cross sectional area Page 35 of 45 Report Ref No 090 907721 000 Product Service In the United Kingdom the torque test is performed using a socket outlet complying with BS 1363 part 1 1995 including Amendment 1 1997 and Amendment 2 2003 and the plug part of DIRECT PLUG IN EQUIPMENT shall be assessed to BS 1363 Part 1 12 1 12 2 12 3 12 9 12 11 12 12 12 13 12 16 and 12 17 except that the test of 12 17 is performed at not
82. ntended to be P connected to SELV circuits only with the exception of the TNV3 circuit in Model A200 2 3 TNV circuits Type of TNV circuits Model A200 TNV 3 2 3 2 Separation from other circuits and from accessible Basic insulation provided P parts separately certified Y2 capacitors 2 3 2 1 General requirements Basic insulation provided P 2 3 2 2 Protection by basic insulation Basic insulation provided P 2 3 2 3 Protection by earthing No protective earth Class III N A unit TNV compliance not reliant on enclosure grounding 2 3 2 4 Protection by other constructions fo N A 2 3 3 Separation from hazardous voltages No hazardous voltage on the N A board except for TNV3 circuit Insulation employed 3 4 Connection of TNV circuits to other circuits No primary circuits N A Insulation employed 2 3 5 Test for operating voltages generated externally Not specified according to N A 2 3 2 3 or 2 3 2 4 2 4 Limited current circuits 2 4 1 General requirements No limited current circuits N A Frequency Hz N Measured current MA i Measured voltage V Measured circuit capacitance nF or pF 2 4 3 Connection of limited current circuits to other N A circuits Limited powe
83. or building in Not connected directly to Mains National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Product Service Requirement Test Result Remark Page 28 of 33 TV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark Interconnection of units by LPS or Class 2 No interconnection conductors may have field wiring connectors other than specified in 3 3 if wiring is reliably separated Terminals for the connection of neutral conductor Class III equipment intended for identified by a distinctive white marking or other building in Not connected directly equally effective means to Mains Wire binding screw terminal permitted for Class Ill equipment intended for connection of No 10 AWG 5 3 mm or smaller building in Not connected directly conductor if provided with upturned lugs cupped to Mains washer or equivalent retention Terminals accept US wire sizes gauge Class Ill equipment intended for building in Not connected directly to Mains Terminals accept current carrying conductors Class IIl equipment intended for rated 125 of the equipment current rating building in Not connected directly to Mains Field wiring terminals marked to indicate the Class III equipment intended for 2 9 material s of the conductor for the terminals building in Not connected directly used to Mains co
84. ord and plug shall be fitted with a 13 A plug in accordance with Statutory Instrument 525 1997 National Standards Authority of Ireland section 28 13 A Plugs and Conversion Adaptors for Domestic Use Regulations 1997 In Ireland DIRECT PLUG IN EQUIPMENT is Class IIl equipment intended for known as plug similar devices Such devices building in Not connected directly shall comply with Statutory Instrument 526 1997 to Mains National Standards Authority of Ireland Section 28 Electrical plugs plug similar devices and sockets for domestic use Regulations 1997 Addition Class IIl equipment intended for building in Not connected directly to Mains Plugs for the connection of the apparatus to the supply mains shall comply with the Korean requirement KSC 8305 and 8305 Addition EMC not evaluated The apparatus shall comply with the relevant CISPR standards National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 17 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark 1 5 7 1 In Norway resistors bridging BASIC Class Ill equipment intended for INSULATION in CLASS I PLUGGABLE building in Not connected directly EQUIPMENT TYPE A must comply with the to Mains requirements in 1 5 7 2 1 In Norway due to the IT power system used see Class Ill equipment intended for annex V Figure
85. ould be consulted for further details on the national conditions and differences summarized below SPECIAL NATIONAL CONDITIONS The following is a summary of the key national differences based on national regulatory requirements such as the Canadian Electrical Code CEC Part and the Canadian Building Code which are referenced in legislation and which form the basis for the rules and practices followed in electrical and building installations All equipment is to be designed to allow Considered installation in accordance with the National Electrical Code NEC ANSI NFPA 70 the Canadian Electrical Code CEC Part CAN CSA C22 1 and when applicable the National Electrical Safety Code IEEE C2 Also unless marked or otherwise identified installation is allowed per the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 1 4 14 For Pluggable Equipment Type A the protection Not Pluggable Type A in the installation is assumed to be 20A For lengths exceeding 3 05 m external Class III equipment intended for interconnecting flexible cord and cable building in No interconnect cables assemblies are required to be a suitable cable provided type e g DP CL2 specified in the CEC NEC For lengths 3 05 m or less external interconnecting flexible cord and cable assemblies that are not types specified in the CEC are required to have special construction features and identification markings
86. proved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02 If this Test Report Form is used by non CCA members the CIG logo and the reference to the CCA Procedure shall be removed This report is not valid as a CCA Test Report unless signed by an approved CCA Testing Laboratory and appended to a CCA Test Certificate issued by an NCB in accordance with CCA e Page 2 of 45 Report Ref No 090 907721 000 Product Service Test item description ePCI PCI Network Cards Analog Voice Card Digital Data and Voice Networking Cards Trade Mark SANGOMA Manufacturer Sangoma Technologies Inc 50 McIntosh Dr Ste 120 Markham ON L3R 9T3 CANADA Model Type reference A101 A102 A104 A108 A200 Series RAUNDE ette nana Models A101 A102 A104 A108 3 3Vdc 1 7A 5Vdc 1 5A Model A200 3 3Vdc 1 7A 5Vdc 1 5A 12Vdc 0 7A Class III Equipment Testing procedure and testing location D CB CCA Testing Laboratory Testing location address T V PRODUCT SERVICE 5 Cherry Hill Drive Danvers MA 01923 USA Associated CB Laboratory Testing location address Tested by name signature IR C T David Dorfner amp aed D In ede Approved by signature William Stinson dll TE Summary of testing
87. r Permanently connected equipment 1 7 2 4 IT power distribution systems Class III product intended for N A building in Not directly connected to Mains 1 7 2 5 Operator access with a tool To be evaluated in the end N A product 1 7 3 Short duty cycles Po N A 1 7 4 Supply voltage adjustment Class III product intended for N A building in Not directly connected to Mains Methods and means of adjustment reference to N A installation instructions 1 7 5 Power outlets on the equipment No power outlets N A 1 7 6 Fuse identification marking special fusing Fuse identification provided P characteristics cross reference on all models 1 7 7 Wiring terminals No wiring terminals N A 1 7 7 1 Protective earthing and bonding terminals No protective earth Class III N A unit TNV compliance not reliant on enclosure grounding 1 7 11 Durability Page 7 of 45 Report Ref No 090 907721 000 1 7 7 2 Terminals for a c mains supply conductors 1 7 7 3 Terminals for d c mains supply conductors Controls and indicators Identification location and marking Colours Symbols according to IEC 60417 Markings using figures Isolation of multiple power sources
88. r sources Eu un a Inherently limited output Not a limited power source N A e Page 10 of 45 Report Ref No 090 907721 000 Product Service c Regulating network limited output under normal operating and single fault condition BEEN d Overcurrent protective device limited output EE Max output voltage V max output current A max apparent power VA i Current rating of overcurrent protective device A Po Provisions for earthing and bonding 2 6 1 Protective earthing No protective earth Class Ill unit TNV compliance not reliant on enclosure grounding 2 6 3 Protective earthing and protective bonding conductors 2 6 3 2 Size of protective earthing conductors E Rated current A cross sectional area mm nUUCcE 2 6 3 3 Size of protective bonding conductors Rated current A cross sectional area mm PWG coi vescecensancdccevebedatasdacdecaveatesentancdaadvandedanvencecetvent Protective current rating A cross sectional area mm AWG 2 6 3 4 Resistance of earthing conductors and their terminations resistance Q voltage drop V test current A duration min 2 6 3 5 Colour of insulation seeeeeeeeee 2 6 4 2 Protective earthing and bonding terminals Rated current A type nominal thread diameter IVAN 25 M E 2 6 4 3 Separation of the protective earthing conductor from protective bond
89. rator 1 5kV Dielectric performed immediately afterwards Page 45 of 45 Report Ref No 090 907721 000 Product Service TABLE Fault condition tests Power source for EUT Manufacturer model type output rating Supply Test Fuse Fuse voltage time current Supplementary information Class Ill product intended for building in Not directly connected to Mains Single fault testing only relevant in the end application Page 1 of 33 TOV Report Reference No 090 907721 000 Date of issue 2009 11 12 Product Service Attachment No 1 National Differences and Group Differences for IEC 60950 1 2 edition 2005 as published by IEC 2008 06 30 Originated by TUV Product Service GmbH Explanation for Abbreviations Possible Verdicts P Pass F Fail N Not Applicable Remarks Throughout this report a point is used as the decimal separator Report reference No 090 907721 000 Date of issue seeennee 2009 11 12 National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 2 of 33 TOV Report Reference No 090 907721 000 Date of issue 2009 11 12 Product Service COUNTRIES Country Group differ National differ National standard AT Austria Yes OVE Yes AU Australia AS NZS 60950 1 SAI Global BE Belgium Yes CEBEC Yes CA Canada Yes CAN CSA C22 2 No 60950 1 07 CSA Yes ENTELAC ULC z CH Switzerland Yes Yes ELECTROSUISSE Yes Yes CN
90. s Internal e g card cage SELV circuit Equipment intended for building in connectors and printed wiring board connectors No SELV circuit connectors or that are accessible to the operator and that printed wiring board connectors that deliver power are to be overloaded are accessible to the operator During abnormal operating testing if a circuit is interrupted by the opening of a component the test shall be repeated twice three tests total Equipment intended for connection to Figure 6C employed telecommunication network outside plant cable is required to be protected against overvoltage from power line crosses in accordance with 6 4 and Annex NAC Continuous ringing signals up to 16 mA only are No ringing signals generated N permitted if the equipment is subjected to special installation and performance restrictions Equipment connected to a telecommunication Equipment intended for building in N and cable distribution networks and supplied Equipment not supplied with an with an earphone intended to be held against or earphone in the ear is required to comply with special acoustic pressure requirements National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 9 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark Document paper shredders likely to be used in Not a paper shredder
91. s from a mains suplply For an a c mains supply s es For a d c mains supply b Transients from a telecommunication network Creepage distances Minimum Measurement Measured 1 68mm from pins 7 to 10 on J3 to confirm Basic Insulation provided btween TNV3 and SELV 2 10 42 Material group and caomparative tracking index Material group Illb is assumed to be used GTI testes gc IEEE Testing not required Za 2 10 4 3 Minimum creepage distances Provided as noted above oP 2 10 5 Solid insulation No solid insulation relied upon Number of layers pcs 210 59 _ Thin sheet material standardtest procedure MA Resegne 2105 10 Thin shoot materal ateraive est procedwe NA Bewwewhes a CS Page 14 of 45 Report Ref No 090 907721 000 Product Service Working voltage PNA a Basic insulation not under stress o NA b Basic supplemetary reinforced insulation NA c Compliance with Annex U ssssses Two wires in contact inside wound component angle between 45 and 90 sssuusss 2 10 5 13 Wire with solvent based enamel in wound components Electric strength test Routine test 2 10 5 14 Additional insulation in wound components Working voltage ee Basic insulation not u
92. s insulation under the following conditions the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN 132400 which in addition to the Y3 testing is tested with an impulse test of 2 5 kV defined in EN 60950 1 2006 6 2 2 1 the additional testing shall be performed on all the test specimens as described in EN 132400 the impulse test of 2 5 kV is to be performed before the endurance test in EN 132400 in the sequence of tests as described in ENj33e fDitterences IEC 60950 1 2hd ed Rev 00 2008 06 Page 15 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark The exclusions are applicable for Class Ill equipment intended for PERMANENTLY CONNECTED EQUIPMENT building in Not connected directly PLUGGABLE EQUIPMENT TYPE B and to Mains equipment intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied e g in a telecommunication centre and which has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON For requirements see 6 1 2 1 and 6 1 2 2 of this Not intended for connection to Cable annex Distribution Systems The term TELECOMMUNICATION NETWORK in 6 1 2 being replaced by the term CABLE DISTRIBUTION SY
93. solid insulation 2 3 2 In Sweden there are additional requirements for Model A200 Bridging Y2 capacitors the insulation See 6 1 2 1 and 6 1 2 2 of this from TNV to SELV are approved to annex 5 1 7 1 In Sweden TOUCH CURRENT measurement Class III equipment intended for results exceeding 3 5 mA r m s are permitted building in Not connected directly only for the following equipment to Mains STATIONARY PLUGGABLE EQUIPMENT TYPE A that o is intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied for example in a telecommunication centre and e has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and o is provided with instructions for the installation of that conductor by a SERVICE PERSON e STATIONARY PLUGGABLE EQUIPMENT TYPE B STATIONARY PERMANENTLY CONNECTED EQUIPMENT National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 22 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark In Sweden add the following text between the first Model A200 Bridging Y2 capacitors and second paragraph of the compliance clause from TNV to SELV are approved to If this insulation is solid including insulation forming UL CSA 60950 1 and provide Basic part of a component it shall at least consist of either insulation Tested at 1 5kV
94. sulation by a VDR Power interface 1 6 1 AC power distribution systems Class III product intended for N A building in A 1 6 2 Input current Measurements not required gt gt gt gt iss isa B 1 5 8 iss sat ssa isss mM gt Oo e Page 6 of 45 Report Ref No 090 907721 000 Product Service Voltage limit of hand held equipment Not a hand held device N A 1 6 4 Neutral conductor Class IIl product intended for N A building in 1 Marking and instructions 7 1 7 1 Power rating Class III product intended for N A building in Marked ratings not required Rated voltage s or voltage range s V N A Symbol for nature of supply for d c only PO N A Rated frequency or rated frequency range Hz tO N A Rated current MA or A seessssss Po N A Manufacturer s name or trade mark or identification EE N A uri qe Model identification or type reference Cae N A Symbol for Class Il equipment only EE N A Other markings and symbols Po a N A 1 7 2 Safety instructions and marking User manual provided P 1 7 2 2 Disconnect devices Class IIl product intended for N A building in No such component 1 7 2 3 Overcurrent protective device Class III product intended for N A building in Not Type B o
95. tective earth or if surge suppressors are connected between the network terminals and accessible parts have a marking stating that the equipment must be connected to an earthed mains socket outlet The marking text in the applicable countries shall be as follows Laite on liitettava suojamaadoituskoskettimilla varustettuun pistorasiaan National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 13 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark TOUCH CURRENT measurement results Class Ill equipment intended for exceeding 3 5 mA r m s are permitted only for building in Not connected directly the following equipment to Mains STATIONARY PLUGGABLE EQUIPMENT TYPEA that o is intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied for example in a telecommunication centre and e has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and o is provided with instructions for the installation of that conductor by a SERVICE PERSON e STATIONARY PLUGGABLE EQUIPMENT TYPE B STATIONARY PERMANENTLY CONNECTED EQUIPMENT National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 14 of 33 TOV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement
96. the impulse test of 2 5 kV is to be performed before the endurance test in EN 132400 in the sequence of tests as described in EN 132400 National Differences IEC 60950 1 2nd ed Rev 00 2008 06 Page 23 of 33 TV Report Reference No 090 907721 000 Product Service Date of issue 2009 11 12 NATIONAL DIFFERENCES GROUP DIFFERENCES Requirement Test Result Remark In Sweden the exclusions are applicable for Class Ill equipment intended for PERMANENTLY CONNECTED EQUIPMENT building in Not connected directly PLUGGABLE EQUIPMENT TYPE B and to Mains equipment intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied e g in a telecommunication centre and which has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON In Sweden for requirements see 6 1 2 1 and Not intended for connection to Cable 6 1 2 2 of this annex Distribution Systems The term TELECOMMUNICATION NETWORK in 6 1 2 being replaced by the term CABLE DISTRIBUTION SYSTEM In Sweden there are many buildings where the Not intended for connection to Cable screen of the coaxial cable is normally not Distribution Systems connected to the earth in the building installation Equipment able to be installed in accordance with Class III equipment intended for ANSI NFPA 75 and NEC Art 645 unless intended bui
97. tion units if the supply branch circuit protection is not suitable Power distribution transformers distributing power at 100 volts or more and rated 10 kVA or more require special transformer overcurrent protection Wiring methods terminals leads etc used for the connection of the equipment to the mains shall be in accordance with the NEC CEC Power supply cords are required to have attachment plugs rated not less than 125 percent of the rated current of the equipment Equipment connected to a centralized d c power system and having one pole of the DC mains input terminal connected to the main protective earthing terminal in the equipment is required to comply with special earthing wiring marking and installation instruction requirements Permanent connection of equipment to the mains supply by a power supply cord is not permitted except for certain equipment such as ATMs Power supply cords are required to be no longer than 4 5 m in length Flexible power supply cords are required to be compatible with Tables 11 and 12 of the CEC and Article 400 of the NEC Permanently connected equipment is required to have a suitable wiring compartment and wire bending space Class IIl equipment intended for building in Not connected directly to Mains No such fuse Class IIl equipment intended for building in Not connected directly to Mains Class IIl equipment intended for building in Not connected directly to
98. two layers of thin sheet material each of which shall pass the electric strength test below or one layer having a distance through insulation of at least 0 4 mm which shall pass the electric strength test below If this insulation forms part of a semiconductor component e g an optocoupler there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing so that CLEARANCES and CREEPAGE DISTANCES do not exist if the component passes the electric strength test in accordance with the compliance clause below and in addition passes the tests and inspection criteria of 2 10 11 with an electric strength test of 1 5 kV multiplied by 1 6 the electric strength test of 2 10 10 shall be performed using 1 5 kV and is subject to ROUTINE TESTING for electric strength during manufacturing using a test voltage of 1 5 kV It is permitted to bridge this insulation with a capacitor complying with EN 132400 1994 subclass Y2 A capacitor classified Y3 according to EN 132400 1994 may bridge this insulation under the following conditions the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN 132400 which in addition to the Y3 testing is tested with an impulse test of 2 5 kV defined in EN 60950 1 2006 6 2 2 1 the additional testing shall be performed on all the test specimens as described in EN 132400
99. uipment is to be installed 3 A suitable fire electrical mechanical enclosure shall be provided in the end system application 4 Minimum 26AWG telecommunication line cord is supplied with the equipment The EUT models A101 A102 A104 and A108 are digital data and voice network cards They are not subjected to TNV evaluation as an approved TELCO provided DMARK device providing isolation from the TNV to the EUT must be provided in the end use application The EUT are rated for a maximum ambient temperature of 50 C Model Similarities A101 and A102 are identical in physical dimensions The only difference is model A102 is a dual port while A101 is a single port A104 and A108 are identical in physical dimensions The only difference is model A104 is a 4 digital port while A108 is an eight port configuration The series of model name are as follow A101 A101D A101E A101DE RSVLC 1002A J9487Y where Y can be any letter from A Z A102 A102D A102E A102DE RSVLC 1002A J9488Y where Y can be any letter from A Z A104 A104D A104E A104DE RSVLC 1002B J9489Y where Y can be any letter from A Z A108 A108D A108E A108DE A200 A200D A200E A200DE RSVLC 1002C J9482Y J9516Y J9518Y where Y can be any letter from A Z No suffix PCI card without echo canceller daughter card D PCI card with echo canceller daughter card E PCI express card without echo canceller daughter card DE PCI express card with echo c
100. ulation forming UL CSA 60950 1 and provide Basic part of a component it shall at least consist of either insulation Tested at 1 5kV two layers of thin sheet material each of which shall pass the electric strength test below or one layer having a distance through insulation of at least 0 4 mm which shall pass the electric strength test below If this insulation forms part of a semiconductor component e g an optocoupler there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing so that CLEARANCES and CREEPAGE DISTANCES do not exist if the component passes the electric strength test in accordance with the compliance clause below and in addition passes the tests and inspection criteria of 2 10 11 with an electric strength test of 1 5 kV multiplied by 1 6 the electric strength test of 2 10 10 shall be performed using 1 5 kV and is subject to ROUTINE TESTING for electric strength during manufacturing using a test voltage of 1 5 kV It is permitted to bridge this insulation with a capacitor complying with EN 132400 1994 subclass Y2 A capacitor classified Y3 according to EN 132400 1994 may bridge this insulation under the following conditions the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN 132400 which in addition to the Y3 testing is tested with an impulse test of 2 5 kV def
101. ulation of at least 0 4 mm which shall pass the electric strength test below If this insulation forms part of a semiconductor component e g an optocoupler there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing so that CLEARANCES and CREEPAGE DISTANCES do not exist if the component passes the electric strength test in accordance with the compliance clause below and in addition passes the tests and inspection criteria of 2 10 11 with an electric strength test of 1 5 kV multiplied by 1 6 the electric strength test of 2 10 10 shall be performed using 1 5 kV and is subject to ROUTINE TESTING for electric strength during manufacturing using a test voltage of 1 5 kV It is permitted to bridge this insulation with a capacitor complying with EN 132400 1994 subclass Y2 A capacitor classified Y3 according to EN 132400 1994 may bridge this insulation under the following conditions the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN 132400 which in addition to the Y3 testing is tested with an impulse test of 2 5 kV defined in EN 60950 1 2006 6 2 2 1 the additional testing shall be performed on all the test specimens as described in EN 132400 the impulse test of 2 5 kV is to be performed before the endurance test in EN 132400 in the sequence of tests as described in EN 132400 In Finland Norway and Swed
102. viding power to other equipment shall be in accordance with the Heavy Current Regulations Section 107 2 D1 Standard Sheet DK 1 3a DK 1 5a or DK 1 7a when used on Class equipment For STATIONARY 224 In Norway for requirements see 1 7 2 1 6 1 2 1 and 6 1 2 2 of this annex 2 2 4 2 3 2 In Finland Norway and Sweden there are additional requirements for the insulation See 6 1 2 1 and 6 1 2 2 of this annex In Norway for requirements see 1 7 2 1 6 1 2 1 and 6 1 2 2 of this annex 2 6 3 3 In the United Kingdom the current rating of the circuit shall be taken as 13 A not 16 A 2 B 5 8 7 5 7 1 In the United Kingdom to protect against excessive currents and short circuits in the PRIMARY CIRCUIT of DIRECT PLUG IN EQUIPMENT tests according to 5 3 shall be conducted using an external protective device rated 30 A or 32 A If these tests fail suitable protective devices shall be included as integral parts of the DIRECT PLUG IN EQUIPMENT so that the requirements of 5 3 are met 2 10 5 13 In Finland Norway and Sweden there are additional requirements for the 1 7 2 1 In Finland Norway and Sweden CLASS PLUGGABLE EQUIPMENT TYPE A intended for connection to other equipment or a network shall if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts have a marking stating that the equipment must be connected to an earthed mains socket outl