Back View - DPS Telecom

image

Contents

1. p Unmuted lt 444 5 Call Terminated system normal 1 Unmuted Fig 13 Order of operation in the no privacy mode No Privacy Refer to Fig 13 In the no privacy mode monitor speakers remain on when the system is in use and any station may get on the system at any time A station s monitor speaker mutes only when the station phone is taken off hook UM119789 6 Unmuted Ring pue et Off Hook NOTE Station code does not have to be dialed to enter conversation FDO 1000 11A 0V SWAV November 22 1999 1 Off Hook Hoot n Holler Unmuted Unmuted Hey Joe a y Off Hook par Facility P R Hey Joe Muted os Off Hook Talk A Off Hook z gt i zZ D NOTE Station code does not have to be dialed to enter conversation Off Hook N cad Off Hook Unmuted gt ey i Unmuted R mst 444 Fig 14 Order of operation in the hoot n holler mode Hoot n Holler Refer to Fig 14 A 4 wire telephone and an external speaker can turn the FDO 1000 into a classic hoot n holler order wire The speaker should be lo cated where it can be heard by all parties at a facility The phone is used to announce the desired party over the mon itor speakers When the person answers the speaker is muted All other sites continue to monitor the order wire channel over the speakers This application can use the FDO 1301 phone and FDO 1200 speaker FDO 100
2. der is placed these jumpers will be factory installed In its simplest configuration the SWAV card is avail able in an otherwise unpopulated shelf Blank SWAV Fig 6 Basic SWAV package Order Wire Packages with the SWAV The FDO 1000 Order Wire with SWAV can be com bined with a DPS KDA 864 E2A network element for alarm applications via SONET Figs 5 7 22 and 24 Order Wire SWAV KDA network element Blank Fig 7 SWAV Satellite KDA E2A package FDO 1000 11A 0V SWAV 3 November 22 1999 Order Wire SWAV KDA network element Scan 4 Fig 8 SWAV Satellite KDA E2A Scan 4 package The FDO 1000 Order Wire with SWAV can be com bined with a DPS KDA E2A equipped with a Scan 4 four port TBOS scanner to make a satellite terminal to provide a voice and discrete TBOS alarm E2A VF inter face to SONET Figs 5 8 and 23 Order Wire SWAV Fig 9 SWAV Order Wire expansion package An expansion package is available to add an order wire to a site with an existing KDA network element Fig 9 The FDO 1000 Order Wire with SWAV can be combined with an FDO 3000 Off Net to make a terminal order wire Order Wire SWAV Off Net Blank Fig 10 SWAV Order Wire Off Net package with off net for interfacing voice and a PSTN connection to SONET The expansion card is not used in off net for this appl
3. in a rack 19 or 23 Rack 5 Projection oo 19 or 23 Rack o9 or acl o o Flush Front 5 o o 19 or 23 Rack 5 1 2 Projection o o O oo O o 19 or 23 Rack oo Oo 1 2 Projection o O o e P NOTE Use wide ears for 23 SIDE VIEW Fig 15 Position mounting ears for desired projection UM119789 NOTE Speaker ground SG is at Batt potential Do not ground it to frame or other equipment ea a a ee a ae ih mot paleji EELNE External Speaker DPS INC FDO 1200 10A 00 m SPKR C1 9E To FDO 1000 gF Order Wire terminal Fig 16 Connecting the FDO 1200 Speaker 4 Mount the external speaker and connect to wire wrap block C1 per Fig 16 5 Mount the phone per Fig 17 Connect to RJ 12 jack on the back of the order wire 6 Make sure the fuse is removed from the front panels of both the order wire and the SWAV 7 Remove Order Wire P C board from housing 8 Connect all inputs and outputs per Fig 18 9 Connect power per Fig 18 10 Set station number on rotary switches per Fig 19 Use leading zeroes to set for 1 or 2 digit coding Refer to Table A for code assignments 11 Apply station code numbers to front panel per Fig 19 12 Set DIP switch for operating mode per Fig 19 Factory default is automatic privacy 13 Set speaker trim pot per Fig 19 14 If a package with companion shelves is being in stalled add
4. phone and reverse the handset tab Refer to Lucent user s manual for details Replace directory card E Connect handset cord and place handset on base NOTE This phone has been converted to 4 wire Do not connect it to a POTS line F Connect phone cable to back of order wire b Select either the standard cord provided with the phone or the optional 25 foot accessory cord 4W Phone S Audio to from 202 Modem 7 Auxiliary Port a K SWAV Card port to J h j ili umpers shown Direct Port ae p Vis Auxiliary ly KDA E2A are factory installed when application is Bridge Ports UH OP a Speaker dicts Network Element known A 4 K i or alarm network Order Wire ayy RXNWK Wire Wrap RX g A When used with a KDA 864 E2A Roce DStaIS Ba ac network element Jumper Order Wire i C3 10A to KDA C3 10C 10B to 10C 10C to 10A and 10D to 10B Plug order wire phone in here Power q DB9 Male 5 ae oooof O 6 9 When used with Off Net connect order wire Db9 VF to off net DB9 VF Fig 18 Order wire interfaces network on wire wrap pins at the rear of the housing UM119789 FDO 1000 11A 0V SWAV November 22 1999 These jumpers are installed only when the passive bridge is used J11 amp J12 Preset maximum speaker level with the speaker trim pot at 7 o clock position terminate F 7 If ADPCM is used place all z EE aes pot 2 brid
5. state If any other phone is picked up during the busy state a busy signal will sound in the earpiece Busied stations remain in that state until their station code is dialed from the caller s phone or until the caller hangs up generating an on hook tone Table of Contents Descriptio 6 disis seccaie eres age a a a 1 SWAV Interface cece eee eee e eee eee 2 Applications is 5346 42356 Sede alee alas aoa 8 3 Order wire packages with the SWAV 3 Operation Modes cece cece cece eens 4 Shipping List sses 0 cece ccc cece eee cece eens 8 Installation 2 0 0 0 cece ccc cece cee eee ree e eee 8 Reference Figures 0 cee cece cece ec ec eens 8 Test and Acceptance cc ccc eee eee cece ees 18 Specifications ccc ccc cece cece cece ees 20 Options and Model Numbers 0005 20 UM119789 4 1 2 square b can mount on rack side rail i Speaker with or any flat surface A Je DPS we Level Control Q AT i VF Line Fig 2 Order wire packages include external speaker phone SWAV and rack mount housing Wire Wrap and Connectorized Back Panel All network power and auxiliary connections are made at wire wrap blocks and connectors on the back panel An RJ 12 jack is provided for the phone and screw terminal barriers are provided for the power office battery voice input output bridge port connections fuse alarm external buzzer speaker and M
6. to 3000 Hz Signaling Standard DTMF All Call Programmable option Station Call 1 2 or 3 digit Physical Size 1 3 4 X 19 X 12 case Weight 3 Ibs Voltage Range Option 0 18 to 72 VDC Option 2 18 to 36 VDC Option 4 36 to 72 VDC Current 500 mA Fuse 1 Amp Speaker Amplifier 2 Watts 8 Ohms included FDO 1000 10A OV VF Order Wire w o phone Options V 1 120VAC 2 24VDC 4 48VDC D PC 802 11C 04 Replacement card 48 VDC D PC 806 11C 04 SWAV card 48 VDC Companion Off Net FDO 3000 10A OV Off Net Interface for Order Wire D PC 801 11C 04 Replacement card 48 VDC Accessories FDO 1200 10A 00 External Speaker Wall Mount FDO 1301 10A 00 Trimline Phone w DTMF Dial 4 wire beige FDO 1301 10A 01 Trimline Phone w DTMF Dial 4 wire white FDO 1501 10A 00 Active 4 way 4 wire Bridge DPS Telecom 4955 E Yale Fresno CA 93727 Phone 559 454 1600 800 622 3314 FAX 559 454 1688 Your Partners In Telecom Management Networks e mail sales dpstele com Visit our web site at http www dpstele com UM119789 20 FDO 1000 11A 0V SWAV November 22 1999
7. wire i wrap blocke F I ALM RTN 4 35 36 37 38 C E a S E E E Trire i O O L EERE LIII 4 8 D CS 228 10A 00 mt mt lI iI LE I 54 55 56 67 5 Connect alarm point 1 here Cl onts 41 50 2 Points 11 20 shaded pins A other points are above or in the shaded areas Wire Wrap 202 Modem E2A Port Block C3 Connections Alarm Details points 61 63 Back View ulti Speaker ao KDA 864 E2A SWAV Satellite KDA E2A SWAV E ce D PG 401 11C 00 KDA network element 8 20 99 Fig 22 401 package combines order wire and KDA E2A network element in VF SONET application 7 po T4 R1 Shield Control points Fuse alarm 1 8 To SpectralWave VF ports FDO 1000 11A 0V SWAV 13 UM119789 November 22 1999 4W Phone Auxiliary Port Auxiliary Oe econ Italai Bridge Ports UH o P e Speaker le 222 Modem 23 4RXNWK_ port to Order Wire ayy tn iy KDA E2A Wire Wrap RX l Network Element Block Details TX tor alarm network TX I I External Speaker Plug order wire External Byzzer h phone in here Expansion card wire wrap block 3e zro fees 8 gt NOTE1 Connect alarm point 1 Rae AET 41 os suri areicbons Back View Points 11 20 shaded pins nha shaded orcas Ow O
8. 0 11A 0V SWAV 7 UM119789 November 22 1999 On Off Hook Function The factory default uses and tones for controlling privacy functions In cases where these tones are already in use for other functions switch SW5 3 can be set ON to change control to the fourth column A and C tones The fourth column buttons are not provided on the phone so manual privacy will not work if SW5 3 is ON Off Net Function When an FDO 3000 Off Net is used in the order wire network the automatic privacy mode should be used for best control of off net access In the other modes there is limited control With manual privacy you must press to lock out an outside call and to disconnect an outside caller NOTE If an outside caller presses the call will be terminated With no privacy and hoot n holler modes an outside call can interrupt an on going conver sation and there is no way to force a disconnect Shipping List a SWAV Interface Card D PC 806 11C 04 a Shelf D CS KDATYPEV a Mounting Hardware 1 005 0001 00 a Fuses a Operation Guide UM119789 a Interconnecting cables Below included with Packages 401 404 only a FDO 1000 Order Wire card D PC 802 11C 04 a Speaker FDO 1200 10A 00 a Telephone FDO 1301 10A 01 a 25 foot Handset Cord 1 675 0010 01 Installation 1 Unpack the order wire and all accessories 2 Install mounting ears for 23 or 19 rack Position as required per Fig 15 3 Mount the order wire terminal
9. 7 UM119789 November 22 1999 J14 23db pad J13 OffNet J15 Termination 23db pad Data Termination will Lucent MEOO5A DC DC Power Module IN DC 48V 0 13A OUT DC SV 1A MADE IN USA US Patent asozia AL gt Kod PAD SETTINGS J17 J18 23db pad DPS O W Termination Note Factory Setting pads out and ports terminated Fig 28 Set option jumpers on the SWAV card UM119789 18 WHE THNH mumi umm ammit 7a NE FDO 1000 11A 0V SWAV November 22 1999 Adjust Level to Monitor Equipment CW for loss SWAV DATA PORT DATAPORT gap ow owleap capl RX PWR 1 4 AMP GMT RX TX TX RX LVL Fa O e o o o DPS Telecom Order Wire Equipment Receive Data Drop Order Wir Receive Transmit Equipment Data Drop Transmit Equipment Receive Signal Out Signal going from SONET out of SWAV ANS ppa Signal In Equipment to SONET gt Transmit Signal going into SWAV Fig 29 LEDs on Order Wire and ADPCM show device status Test and Acceptance a Calibrate levels per Table H NOTE If the order wire is equipped with an ADPCM the levels will be pre set at the factory and this step may be skipped a Perform a general test of the order wire by calling a few stations and having a station call back in to the site you are installing FDO 1000 11A 0V SWAV 19 November 22 1999 UM119789 Table H Level set procedure for automatic privac
10. DOD DPS Telecom Your Partners In Telecom Management Networks User Manual SWAV Interface Packages Package Description The SWAV Interface package is available in several configurations for interfacing Order Wire voice and alarm system data to a the VF ports of a SONET network using NEC SpectralWave terminals FDO 1000 Order Wire Description With DPS FDO 1000 Order Wire terminal your ana log or digital network can become your own private phone system with links to the public telephone network The order wire is an economical party line system that requires no central switching An order wire terminal and telephone are located at each facility in your network The order wire system is simple to operate and can signifi cantly reduce your voice communications costs DTMF Selective Signaling The DPS FDO Order Wire uses the on board micro processor to synthesize and decode DTMF signaling tones The FDO can be programmed for automatic pri vacy manual privacy no privacy and hoot n holler oper ating modes LED Indicators Front panel LEDs indicate order wire off hook incom ing call ringing and channel busy Front panel test points and level controls are provided for calibration Addressing The Order Wire responds to one two or three digit ad dressing Leading zeroes in the address will set it for one or two digits Rotary switches on the P C Board allow the address to be easily set The station address is posted on
11. P LINE 2 CH 1 RECEIVE P3 5 P3 6 VF2 1RXB P3 35 VF2 2TXA ILAMP LINE 2 CH 2 TRANSMIT P3 36 VF2 2TXB P3 33 VF2 2RXA ILAMP LINE 2 CH 2 RECEIVE P3 34 VF2 2RXB l ttt woe WIW Block ct Port 2 not used WIW Block c1 External Panel Dial Port not used Direct Port 6 DB9 Male VF To Off Net Wiring on outside of wire wrap block for all sites Block Diagram Order Wire with SWAV Card Batt Gnd P3 27 OWOUT owour fe328 owin E225 OWIN 9 30 99 OFFNET IN OFFNET IN OFFNET OUT OFFNET OUT DATA DROP OUT DATA DROP OUT DATA DROP IN DATA DROP IN 23db pad O W East S p 23db pad O W West 4 Data Private Line DB50 23db pad East 4 lt 23db pad 4 OFFNET Default Out 23db pad Optional Fig 21 Order wire package is pre wired for digital application 12 FDO 1000 11A 0V SWAV November 22 1999 4W Phone Auxiliary Port atoy netted Bridge Ports B 202 Modem a port to Order Wire py tntINC KDA E2A Wire Wrap RX A Network Element Block Details TX IB or alarm network External Speaker Plug order wire _ External Byzzer phone in here GND FRAME DB50 Female 1 DB9 Male 5 04 ON o a EY M A A 2 ear 34 35 36 37 3 ALM RTN i A Expansion I Li card
12. ge jumpers in the open terminate y storage position If passive bridge is used strap in terminations on unused ports Set calling code address on three rotary switches Second Digit Third Digit terminate port 4 Apply station code numbers to front panel Hoot n Holler No Privacy Manual Privacy Automatic Privac OFF OFF Off hook On hook OFF Off hook A On hook C ee Wow Fig 19 Set order wire options before applying power To SpectralWave To Order Wire To Off Net If equipped ADPCM 2 VF o zm lt o gt o gt boc o Section A NETWORK Section B Data Fig 20 When installing an order wire package connect inter shelf cables FDO 1000 11A 0V SWAV 11 UM119789 November 22 1999 WM Block C1 9E oF 9A 9B 9c 9D 2 D L o re a QO 17 UM119789 Aux Port not used Spkr Spkr Com Aux Spkr Out Aux Spkr In A Aux Spkr In B FDO 1000 Aux Spkr In C s Order Wire Fuse Alarm Fuse Alarm Ext Buzzer To 4 W Phone Ext Buzzer Rtn P1 43f Mic Com B P1 45 Mic Fuse Alarm VF1 1TXA ILAMP LINE 1 CH 1 TRANSMIT VF1 1TXB P3 11 P3 12 P3 9 VF1 1RXA ILAMP LINE 1 CH 1 RECEIVE P3 10 vF1 1RXB SWAV P3 23 VF1 2TXA ILAMP LINE 1 CH 2 TRANSMIT P3 24 vF1 27xB VF1 2RXA ILAMP LINE 1 CH 2 RECEIVE P3 22 vF1 2RXB P3 7 P3 21 VF2 1TXA ILAMP LINE 2 CH 1 TRANSMIT P88 f vF2 17xB VF2 1RXA ILAM
13. ication UM119789 1 Off Hook Automatic Privacy Dial Tone Off Sun am ay te y Off Hook Ton N 5 Voice Facility A Muted Busy Tone Busy Muted lt mS e F 0 DTMF Tones side tone 333 gt Voice Facility oe Off Hook Dial Code Muted Busy Tone Busy Tone 2a Alternate dial w page 8 station code D DTMF Tones a side tone Off Hook Dial Code Busy Busy Tone 3 Call Answered 7 Off hook tone Off Hook Off Hook Tone 5 lt a Fig 11 Order of operation in the automatic privacy mode Operation Modes Automatic Privacy Refer to Fig 11 In the automatic privacy mode the FDO order wire performs like a normal private line tele phone The caller hears dial tone when the phone is first taken off hook and an off hook tone is broadcast to busy out the network When the caller dials the three digit code for a station the buzzer at that station sounds and the caller hears a ring back tone When the called party an swers the ring back and buzzer are silenced and conver sation may proceed During the conversation all other sta tions will hear a busy signal in the handset and all monitor UM119789 speakers are muted Either party hanging up generates an on hook tone to clear the busy state In this mode the calling party may page the desired party over the called station s speaker by dialing 8 prior to enter
14. ing the three digit station code NOTE Avoid using station codes starting with 8 The busy state may be manually cleared by pressing the button It can be restored by pressing the button Other parties can be added to the conversation at any time FDO 1000 11A 0V SWAV November 22 1999 1 Off Hook Manual Privacy Dial T ay Bene Off Hook 2 Dial Station Code DTMF Tones side tone p Off Hook 333 a Da Voice ng Fey Unmuted 3 Dial Code 4 444 3 Call Answered Unmuted Muted Off Hook Off Hook Talk ae 5 gt Voice Facility d Unmuted Wey 444 3 Invoking Privac Busy Tone g y i Bus AD g a Press E z Off Hook Cre Off Hook Fig 12 Order of operation in the manual privacy mode An all call code rings all stations Unanswered sta tions will time out in 90 seconds Manual Privacy Refer to Fig 12 The manual privacy mode works like the automatic privacy mode except that the caller must press the key to establish the busy state It is released by dialing a or by hanging up the phone FDO 1000 11A 0V SWAV 5 UM119789 November 22 1999 1 Off Hook No Privacy i Unmuted Muted Dial T a DORO Off Hook Z 2 Dial Station Code DTMF Tones n side tone Off Hook BE 3 Dial Code 3 Call Answered Off Hook Talk we gt Facility d dD Unmuted i we om Talk C Off Hook Facility
15. ion Details 2Ww POTS line To SpectralWave VF ports ll Fuse alarm 45678910 Speaker Jumpers are factory installed for Off Net application 2W POTS Line D PG 404 11C 00 Front View 8 20 99 Fig 26 404 package combines order wire and off net interface in VF SONET application UM119789 FDO 1000 11A 0V SWAV November 22 1999 202 Modem port to KDA E2A Network Element or alarm network Plug order wire phone in here DB50 Female 1 DB9 Male 5 o xr exo Frame Lel sejra rg 34 35 36 37 i A Expansion rt rt card wire oi wrap blocke it F ALM RTN 6 37 tf ot TT LEL ALM tt RTN 5 I I T Li I Li zje o 4 I I T Li I Li 4 of tt ot tf tf rt rt 8 54 55 56 57 58 59 6 C5 C6 C7 Ci D CS 228 10A 00 Connect alarm point 1 here C1 points 41 502 C3 Points 11 20 shaded pins A other points are above or in the shaded areas Wire Wrap 202 Modem E2A Port Block C3 Connections Alarm Details points T 61 63 R T1 R1 Back View Control Shield points Fuse alarm 1 8 OW To SpectralWave VF ports E2A Port KDA 864 E2A SWAV Satellite KDA E2A SWAV R 8 20 99 KDA network element Fig 27 407 package has KDA E2A network element in VF SONET application FDO 1000 11A 0V SWAV 1
16. jumper connections per Fig 20 15 Re install P C board in housing 16 Remove SWAV card from shelf 17 Check jumper settings per Fig 26 18 Re install SWAV card in housing 19 Insert fuses at order wire and SWAV front panels 20 Go to Test and Acceptance on page 17 21 Installation is complete Table A Dial Code Assignments Code Assignment 000 thru 009 Single digit dialing Leading zeroes are not dialed 010 thru 099 Two digit dialing Leading zero is not dialed 100 thru 799 Three digit dialing 900 thru 999 TIL All call 8 three digit Page at a station Not functional with all call code Avoid using codes that start with 8 FDO 1000 11A 0V SWAV November 10 1999 This page intentionally left blank FDO 1000 11A 0V SWAV 9 UM119789 November 22 1999 Ge E Figs 22 26 show the details of the various SWAV Reference Figures order wire packages offered Fig 21 illustrates the shelf wiring diagram A Install duplex adaptor plate B Use the provided mounting on quad box opening studs and screws to install Skip if a duplex box is the phone mounting plate already in place on duplex opening C Connect cable to back of phone Feed cable through opening in mounting plate and thread through duplex or quad box to back of order wire Install phone base on studs projecting from mounting plate Push base down to secure D Remove directory card from
17. lead connections are all provided on a 60 pin wire wrap block FDO1000 Order Wire Order Wire Electronics SWAV To alarm network or element FDO1000 Order Wire SWAV E VF niliy Port EN S ak Order Wire Electronics Speaker To alarm network or element 4 Wire Phone Fig 3 Accessories for Order Wire include active 4w 4w bridge 4 wire DTMF phone and speaker SWAV The SWAV Interface card fits in the expansion card slot of the order wire chassis It joins the order wire terminal to the network with an auxiliary port for an off net con nection It also provides a separate VF channel for alarm system data The SWAV front panel includes test jacks and level controls to monitor equipment Applications The SWAV Interface is available in application packages that include FDO 1000 Order Wire with KDA alarm net work elements and the FDO 3000 Off Net FDO1000 Order Wire Order Wire Electronics SWAV i ion Speaker 4 Wire Phone To alarm network or element FDO1000 Order Wire Order Wire Electronics SWAV Pac ie sal oa Speaker 4 Wire Phone To alarm network or element POTS Line to PSTN lt q_ _ FDO 3000 Off Net Fig 4 A typical analog order wire network provides voice c
18. ommunications between telecom sites and to the Public Switched Telephone Network PSTN via a Plain Old Telephone Service POTS line UM119789 FDO 1000 11A 0V SWAV November 22 1999 Terminal Terminal _y BR J BRE SWAV BR f SWAV FDO 1000 Order Wire FDO 3000 Off Net FDO 1000 Order Wire KDA 864 E2A FDO 1000 Order Wire FDO 3000 Off Net Off net m Phone RT way cil To E2A BR HBR Off net w To E2A Phone Line FDO 1000 Order Wire KDA 864 E2A Polling Unit or Remote FDO 1000 Order Wire Polling Line Unit KDA 864 E2A Fig 5 SWAV packages equipped with the Order Wire interface voice and data to the VF supervisory ports of an NEC SpectralWave SONET terminal Also see Fig 21 DTMF Selective Signaling Fig 2 shows the basic components of the order wire Station call codes are programmed manually with ro tary switches on the order wire P C board Number labels are provided to place on the front panel to indicate the set ting Each site should be equipped with a 4 Wire DTMF phone and external speaker Wire Wrap Jumpers To utilize the order wire s four way bridge or the SWAYV jumpers must be installed at the wire wrap block When the application details are known at the time an or
19. orts VF Alarm Data Port to alarm network Fig 24 403 package interfaces order wire to VF SONET application 4W Phone Auxiliary Port Direct Port Gen Auxiliary Jumpers shown D 202 Modem A are factory installed Bridge Ports u X 234R Order Wire px Wire Wrap RX Block Details TX ee Speaker port to KDA E2A Network Element or alarm network Plug order wire phone in here DB50 Female 1 DB9 Male 17 5 OA o eenaa ennon o vro R289 o 50 34 6 9 Power SWAV Order Wire Expansion Package D PG 406 11C 00 8 20 99 Fig 25 406 package is for use where parallel SWAV systems are already in place Back View VF Alarm Data Port to alarm network To SpectralWave VF ports FDO 1000 11A O0V SWAV 15 UM119789 November 22 1999 4W Phone Auxiliary Port Direct Port Auxiliary on netted Bridge Ports a Speaker 202 Modem R port to Order Wire px NC KDA E2A Wire Wrap Rx tan C lt M Lead Network Element Block Details TX 1B NO 3 or alarm network TX i SWAV oN Fuse alarm External Dial v Plug order wire phone in here External Speaker External Byzzer DB25 Female 1 PCMO O 25 6 9 8 DB15 Female 1 8 1 DB9 Female 5 1 oaeeo opas o o Freee 0 5 9 6 Data 15 9 1 SectionA Network Section B Alternate RJ 12 Wire Wrap jack for POTS Block C3 line connect
20. rder Wire SWAV ALM 4Wie Mfl e Phone Speaker Control points a 1 8 KDA 864 o L Table B LR 24 SR 24 and Scan4 Expansion Card Pinouts Rly 21A Rly 21B Rly 22A NOTE 1 Rly 22B Install jumper between Rly 23A F4 and F5 for Scan 4 Rly 23B Rly 24A Rly 24B N GND GND GND SWAV Satellite KDA E2A GND plus Scan 4 D w Order Wire Package D PG 402 11C 00 GND GND 8 20 99 Wire Wrap 202 Modem E2A Port Block C3 Connections Alarm Details points 61 63 SpectralWave VF ports Alarm Fig 23 402 package combines order wire and KDA E2A network element with Scan 4 in VF SONET application UM119789 14 FDO 1000 11A 0V SWAV November 22 1999 Jumpers shown 4W Phone Auxiliary Port Direct Port we iw are factory installed Bridge Ports Order Wire ayy Wire Wrap RX 123 I D o Auxiliary s Speaker nl NC 1Aa C lt M Lead 202 Modem port to gt KDA E2A Network Element or alarm network e el i 1B NO i Ci l Fuse alarm X External Speaker External Byzzer Block Details TX TX SWAV ONY External Dial y ea Plug order wire phone in here m CaS o gt mm mm DB50 Female Phone Speaker swav SWAV Order Wire Expansion Package D PG 403 11C 00 8 20 99 To SpectralWave VF p
21. the front panel with stick on labels labels are included Four Wire Phone Voice communications and out dialing occur at a 4 wire telephone mounted near the order wire Call Buzzer A buzzer in the order wire announces incoming calls An optional buzzer can be installed in the phone External speaker The FDO 1000 includes a 2 watt speaker amplifier that can be used to drive an external eight ohm speaker A pag ing feature can be activated from any calling station to al Change Notice FDO 1000 11A 0V SWAV November 22 1999 SWAV DATA PORT DATAPORT gop Rx Ow OwlEaP EOP RX 4 Ea l PRO MAMPCMT Rx XK XK RX M ne M cco e e DPS Telecom NET a Fig 1 FDO 1000 Order Wire Terminal with SWAV in terfaces SONET network via NEC SpectralWave low the desired party s name to be announced over the speaker Passive Bridge Optional Active Bridge The FDO 1000 is facility ready with a built in 4 Way passive bridge and level matching pads for 7 16 dBm channel levels The bridge can also be bypassed for direct interface at the order wire s active VF ports An accessory active bridge can be installed on the order wire s P C board for matching levels other than 7 16 dBm Network Control In privacy modes the FDO 1000 uses automatically generated DTMF tones to control access to the order wire network An off hook tone is generated when a caller picks up the phone which causes other stations on the network to assume a busy
22. y mode using the SWAV Results Step Action 1 Set output level at station A station A b Lift handset and press button 1 a Connect meter to the TX test points on the front panel of Measure no signal Measure some level around 10dBm c Adjust TX level pot on front panel Read 10dBm d Remove meter from test points 2 Set input level at all other stations a Connect meter to the RX test points on the front panel of a sta Measure no signal tion b At station A press button 1 on the phone phone is off hook Measure some level around 10 dBm c Adjust RX level pot on front panel d Proceed with step 3 before moving on to another station Read 10 dBm 3 Set output level at all other stations tion b Lift handset and press button 1 c Adjust TX level pot on front panel d Remove meter from test points a Connect meter to the TX test points on the front panel of a sta Measure no signal Measure some level around 10dBm Read 10dBm 4 Go on to other stations and perform steps 2 and 3 As in steps 2 and 3 5 Return to station A and perform step 2 As in step 2 Specifications Options and Model Numbers VF interface levels Direct Port 16 to 7 dBm VF Interface Levels Bridge Ports 16 dBm Transmit 7dBm Receive Bridge Type 4 Way 4 Wire Passive Bridge Return Loss gt 40 dB Bridge Trans Hybrid Loss gt 56 dB Frequency Range 300