1. Sets PELES lt Pas RARAS te Always have a qualified electrician do your electrical work Switch off power before starting the installation Please review the instructions and warnings prior to starting the installation gt mee gt eS D4 Pidh gt AVAVAVA D VAVAVA AV Instructions for mounting Schematic steps for removing a fluorescent lamp and inserting a LED Tube Retrofit luminaire with one lamp O Electronic C ex Ballast H i oF x X AC 120 277V Line Hot AC120 277V Neutral LED Tube Line Hot AC120 277V Neutral x X LED Tube AC 120 277V LED Tube Line Hot AC120 277V Neutral LED Tube LED Tube LED Tube LED Tube X Before retrofit please confirm the existing fluorescent luminaire s size is larger than the defined dimensions below Minimum luminaire dimension Length Width mm Fit One Fit Three LED Tube LED Tube LED Tube 622 x 600 622 x 600 622 x 600 1232 x 600 1232 x 600 1232 x 600 1232 x 600 1232 x 600 1232 x 600 Electrical characteristics typical value Fit Four LED Tube 622 x 600 1232 x 600 1232 x 600 Fit Two SI L8x10206Ayz SI L8x19112Ayz GU14H3016x8Ayz Voltage Current Power Rated AC V AC A wW Frequency Hz SI L8x10206Ayz _ Dimension SI L8x191
2. 12Ayz 120 277 0 07 0 16 18 GU14H3016x8Ayz 120 277 0 06 0 15 X x V 3000K U 3500K T 4000K R 5000K yz US CA April 2014 Version 2 1 Packing details User Manual AC Direct LED Tube eLED Tube 1pc e User manual 1pc eLabel 3 pcs Installation instructions 1 Switch off power before starting the installation 2 Remove fixture cover or diffuser and the fluorescent lamps 3 Open Remove wiring compartment cover 4 Cut all remaining wires connected to the ballast 5 Replace lampholders with non shunted G13 bi pin sockets if needed 6 Connect one wire from the socket to branch circuit Hot and on the second socket connect the other wire to the branch circuit Neutral 7 Reinstall wiring compartment cover Take care not to pinch crimp or bind wires 8 Remove any existing labels and apply new labels in the appropriate locations as illustrated below A Label locations RISK OF ELECTRIC SHOCK USE IN DRY AND N ANN DAMP LOCATION ONLY D ee eet USE LED TUBES ONLY REPLACE ONLY WITH SAMSUNG LED TUBES 9 Insert the LED tube into the lampholders 10 Switch on power X The AC input end of the LED Tube is marked with the SAMSUNG mark X Samsung s warranty will be void if the labels UL stickers are not applied to the fixture after the modification and installation Sockets Rapid Start Sockets Instant Start Sockets Non Shunted Shun
3. E F40T12 IS FOR MORE INFORMATION CONTACT SAMSUNG ELECTRONICS e INSTALLERS SHOULD NOT DISCONNECT EXISTING WIRES FROM LAMPHOLDER TERMINALS TO MAKE NEW CONNECTIONS AT LAMPHOLDER TERMINALS INSTEAD INSTALLERS SHOULD CUT EXISTING LAMPHOLDER LEADS AWAY FROM THE LAMPHOLDER AND MAKE NEW ELECTRICAL CONNECTIONS TO LAMPHOLDER LEAD WIRES BY EMPLOYING APPLICABLE CONNECTORS Cautions Do not use with dimmers The luminaires shall be grounded Do not touch this product with wet hands For use in dry and damp locations only Do not look directly at the operating LED Tube Do not disassemble repair or alter discretionally Do not use a series connection when installing this product For use only with UL Listed IC or NON IC Recessed Mount Fluorescent Luminaries with or without Diffuser LED Tubes must be operated within an ambient fixture temperature of 4 F 20 C and 122 F S0 C Risk of electric shock Not for use where exposed to the weather Risk of fire or electric shock The electrical rating of this products is 120 277Vac The installer must determine whether they have 120 277Vac at the luminaries before installation For outdoor usage should be installed in a waterproof fixture This product contains chemicals known to the State of California to cause cancer and reproductive toxicity Warranty Product Life Time Warranty Period Limited Conditions Warranty Terms The warranty perio
4. d starts 3 months after the applicable production date This Warranty only applies under the limited conditions outlined above and does not apply to failures caused by abnormal use The Warranty will not apply if you do not adhere to the instructions in this User Manual Any labor costs for the installation and removal of products are not covered under this Warranty Blackouts or flickering caused by product defects E S Lifetime 25 000 Hr Average usage time 12 Hrs Day April 2014 Version 2 1 Linear Replacement Lamp
5. ted Linear Replacement Lamp Samsung Electronics America Inc 85 Challenger Rd Ridgefield Park NJ 07660 Toll free 1 888 899 7607 www samsung com us Dimension Dimension Warnings e DO NOT INSERT FLUORESCENT LAMPS THEY COULD BREAK CAUSING SERIOUS INJURY USE LED TUBES ONLY e DO NOT USE THIS DEVICE TO ILLUMINATE EMERGENCY EXITS e RISK OF FIRE OR ELECTRIC SHOCK LED RETROFIT KIT INSTALLATION REQUIRES KNOWLEDGE OF LUMINAIRES ELECTRICAL SYSTEMS IF NOT QUALIFIED DO NOT ATTEMPT INSTALLATION CONTACT A QUALIFIED ELECTRICIAN e RISK OF FIRE OR ELECTRIC SHOCK INSTALL THIS KIT ONLY IN THE LUMINAIRES THAT HAVE THE CONSTRUCTION FEATURES AND DIMENSIONS SHOWN IN THE PHOTOGRAPHS AND OR DRAWINGS e DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL COMPONENTS DURING KIT INSTALLATION e TO PREVENT WIRING DAMAGE OR ABRASION DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR OTHER SHARP OBJECTS e TO AVOID POTENTIAL FIRE OR SHOCK HAZARD DO NOT USE THIS RETROFIT KIT IN LUMINAIRES EMPLOYING SHUNTED BI PIN LAMPHOLDERS NOTE SHUNTED LAMPHOLDERS ARE FOUND ONLY IN FLUORESCENT LUMINAIRES WITH INSTANT START BALLASTS INSTANT START BALLASTS CAN BE IDENTIFIED BY THE WORDS INSTANT START OR I S MARKED ON THE BALLAST THIS DESIGNATION MAY BE IN THE FORM OF A STATEMENT PERTAINING TO THE BALLAST ITSELF OR MAY BE COMBINED WITH THE MARKING FOR THE LAMPS WITH WHICH THE BALLAST IS INTENDED TO BE USED FOR EXAMPL