1/8 DIN Digital Input Panel Meter Installation

image

Contents

1. o INPUT B on INPUTA o INPUTB gt INPUT B Y Switch or Isolated Transistor Current Sink Switch or Isolated Transistor Current Source Input A Input A 18VouT i gt Quad Current Sink Output Dual Quad Count Current Sink Output Dual Quad Quad Current Sink Output Counter A amp Counter B el o _ a INPUTA SZ gt INPUT B Counter A amp Rate B Single Counter A o USER 1 Count A NPN O C Count 4 o inputs De If using single Counter B then wire signal to 6 and Quad Direction to 9 Set switches as shown Shaded areas not recommended for counting applications USER INPUT WIRING If User Input and or 2 are wired for quadrature or directional counting an additional switching device should not be connected to that User Input terminal User Input terminal does not need to be wired in order to remain in inactive state V SUPPLY 30V max inki in it reouan 1 i ic ii ig USER INPUTS Sinking Logic USrALE L0 USER INPUTS Sourcing Logic U5rALE Hi When the USrALE parameter is programmed to When the USACE parameter is programmed toH Ss Nm LQ the user inputs of the meter are internally 2E z He the user inputs of the mete
2. Prepare the panel cutout to the dimensions shown Remove the panel latch from the unit Slide the panel gasket over the rear of the unit to the back of the bezel The unit should be installed fully assembled Insert the unit into the panel cutout While holding the unit in place push the panel latch over the rear of the unit so that the tabs of the panel latch engage in the slots on the case The panel latch should be engaged in the farthest forward slot possible To achieve a proper seal tighten the latch screws evenly until the unit is snug in the panel Torque to approximately 7 in lbs 79N cm Do not over tighten the screws LATCHING SLOTS PANEL LATCH Y i PANEL GASKET LATCHING TABS PANEL MOUNTING SCREWS Installation Environment The unit should be installed in a location that does not exceed the operating temperature and provides good air circulation Placing the unit near devices that generate excessive heat should be avoided PANEL CUT OUT SETTING THE DIP SWITCHES To access the switches remove the meter base from the case by firmly squeezing and pulling back on the side rear finger tabs This should lower the latch below the case slot which is located just in front of the finger tabs It is recommended to release the latch on one side then start the other side latch power to the meter and load circuits before accessing inside of the Warning Exposed line voltage exists on the circu
3. debounced externally The user input may only be selected for sink source by the User Jumper placement SENSOR POWER 18 VDC 5 60 mA max short circuit protected Note Recommended minimum clearance behind the pane installation is 2 1 53 4 H x 5 5 140 W 44 45 Cj 1 75 H 4 14 105 for mounting clip DIMENSIONS In inches mm REREH HOGRBRABE 33 3 80 96 52 3 60 91 44 SAFETY SUMMARY All safety related regulations local codes and instructions that appear in this literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Do not use this unit to directly command motors valves or other actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event of a fault to the unit CAUTION CAUTION Risk of Danger Risk of electric shock Read complete instructions prior to installation and operation of the unit METER INSTALLATION The PAX2D meets NEMA 4X IP65 requirements when properly installed The unit is intended to be mounted into an enclosed panel
4. extend only to the repair or replacement of a defective product at The Company s option The Company disclaims all liability for any affirmation promise or representation with respect to the products The customer agrees to hold Red Lion Controls harmless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those expressly contained herein The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations 20 Willow Springs Circle York PA 17406 USA 1 717 767 6511 info redlion net www redlion net 4
5. V UL AG Power DC Power approved fuse for DC input It shall be easily accessible and AC DC 1 AC DC marked as a disconnecting device to the installed unit This device A is not directly intended for connection to the mains without a 2 AC DC 2 AC DC 2 AC DC reliable means to reduce transient over voltages to 1500 V AC DC INPUT SIGNAL WIRING CAUTION Sensor input common is NOT isolated from user input common In order to preserve the safety of the meter application the sensor input common must be suitably isolated from hazardous live earth referenced voltage or input common must be at protective earth ground potential If not hazardous voltage may be present at the User Inputs and User Input Common terminals Appropriate considerations must then be given to the potential of the user input common with respect to earth ground and the common of the isolated plug in cards with respect to input common If you are wiring Input B connect signal to Terminal 6 instead of 5 and set DIP switches 4 5 and 6 to the positions shown for 1 2 and 3 Magnetic Pickup AC Inputs From Tach Generators Etc Two Wire Proximity Current Source A Input A Input A 5 13 MAGNETIC PICKUP Resistor to limit current to 2 5 mA MAX Current Sinking Output Current Sourcing Output COMM Ls ox ineur gt INPUT B INPU
6. it boards Remove all meter FRONT DISPLAY Circuit Board USB Connector INPUT SET UP i DIP SWITCHES 5 Finger Finger IIIS REAR TERMINALS SETTING THE INPUT DIP SWITCHES The meter has six DIP switches for Input A and Input B terminal set up that must be set before applying power Input B LO Freq W 6 HI Freq Input B SRC E 5 SNK Input B MAG E 4 Logic Input A LO Freq 3 HI Freq Input A SRC mi 2 SNK Input A MAG ON E 1 Logic W Factory Setting SWITCHES 1 and 4 LOGIC Input trigger levels Vy 1 5 V max Viy 3 75 V min MAG 200 mV peak input sensitivity 100 mV hysteresis maximum voltage 40 V peak 28 Vrms Input impedance 3 9 KQ 60 Hz Must also have SRC switch ON Not recommended with counting applications SWITCHES 2 and 5 SNK Adds internal 7 8 KQ pull up resistor to 5 VDC Imax 0 7 mA SRC Adds internal 3 9 KQ pull down resistor 7 3 mA max 28 VDC Vmax 30 VDC SWITCHES 3 and 6 HI Frequency Removes damping capacitor and allows max frequency LO Frequency Adds a damping capacitor for switch contact bounce Also limits input frequency to maximum 50 Hz and input pulse widths to minimum 10 msec POWER WIRING The power supplied to the meter shall employ a 15 Amp UL approved circuit breaker for AC input and a 1 Amp 250
7. r are internally pulled Ss y E amp pulled up to 3 3 V with 20 KQ resistance The E wo w down to 0 V with 20 KQ resistance The input Q woa a input is active when it is pulled low lt 1 1 V V D D D i is active when a voltage greater than 2 2 VDC 7 8 9 ho i is applied 7 8 9 110 i 5 5 het 3 af PRESCALER OUTPUT WIRING NPN O C COMM PS OUT SETPOINT ALARMS WIRING SERIAL COMMUNICATION WIRING oe A Se ANALOG OUTPUT WIRING 3 i ORDERING INFORMATION DESCRIPTION PART NUMBER Digital Input Panel Meter PAX2D000 Dual Setpoint Relay Output Card PAXCDS10 Quad Setpoint Relay Output Card PAXCDS20 Quad Setpoint Sinking Open Collector Output Card PAXCDS30 Quad Setpoint Sourcing Open Collector Output Card PAXCDS40 RS485 Serial Communications Card with Terminal Block PAXCDC10 Extended RS485 Serial Communications Card with Dual RJ11 Connector PAXCDC1C RS232 Serial Communications Card with Terminal Block PAXCDC20 Extended RS232 Serial Communications Card with 9 Pin D Connector PAXCDC2C DeviceNet Communications Card PAXCDC30 Profibus DP Communications Card PAXCDC50 Analog Output Card PAXCDL10 LIMITED WARRANTY The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment provided the products have been stored handled installed and used under proper conditions The Company s liability under this limited warranty shall
8. r inputs Max Continuous Input 30 VDC Drawing No LP0901A Effective 04 13 Isolation To Sensor Input Common Not isolated PRESCALER OUTPUT NPN Open Collector Igyx 100 mA max Vor 1 VDC max Voy 30 VDC max Duty cycle 25 min and 50 max ENVIRONMENTAL CONDITIONS Operating Temperature Range 0 to 50 C Storage Temperature Range 40 to 60 C Vibration to IEC 68 2 6 Operational 5 150 Hz 2 g Shock to IEC 68 2 27 Operational 25 g 10 g relay Operating and Storage Humidity 0 to 85 max Altitude Up to 2000 meters CERTIFICATIONS AND COMPLIANCES CE Approved EN 61326 1 Immunity to Industrial Locations Emission CISPR 11 Class A IEC EN 61010 1 RoHS Compliant UL Listed File E179259 Type 4X Indoor Enclosure rating Face only IP65 Enclosure rating Face only IP20 Enclosure rating Rear of unit RH non condensing CONNECTIONS High compression cage clamp terminal block Wire Strip Length 0 3 7 5 mm Wire Gauge Capacity One 14 AWG 2 55 mm solid two 18 AWG 1 02 mm or four 20 AWG 0 6 1 mm CONSTRUCTION This unit is rated NEMA 4X IP65 for indoor use only IP20 Touch safe Installation Category I Pollution Degree 2 One piece bezel case Flame resistant Synthetic rubber keypad Panel gasket and mounting clip included WEIGHT 8 oz 226 8 g inputs are inherently a logic input with no low frequency filtering Any mechanical contacts used for these inputs in a dual count mode must be
9. red lit n Tel 1 717 767 6511 Fax 1 717 764 0839 www redlion net PAX2D 1 8 DIN Digital Input Panel Meter Installation Guide c UL US LISTED 3RSD PROCESS CONTROL EQUIPMENT See the Red Lion website at www redlion net or the enclosed USB thumbdrive for a complete user manual SPECIFICATIONS POWER AC Power 40 to 250 VAC 50 60 Hz 20 VA DC Power 21 6 to 250 VDC 8 W Isolation 2300 Vrms for 1 min to all inputs and outputs INPUTS A and B DIP switch selectable to accept pulses from a variety of sources including switch contacts TTL outputs magnetic pickups and all standard RLC sensors LOGIC Input trigger levels Vj 1 5 V max Vy 3 75 V min Current sinking Internal 7 8 KQ pull up to 5 VDC Imax 0 7 mA Current sourcing Internal 3 9 KO pull down 7 3 mA max 28 VDC Vmax 30 VDC Filter Damping capacitor provided for switch contact bounce Limits input frequency to 50 Hz and input pulse widths to 10 msec minimum MAGNETIC PICKUP Sensitivity 200 mV peak Hysteresis 100 mV Input impedance 3 9 KQ 60 Hz Must also have SRC switch ON Not recommended with counting applications Maximum input voltage 40 V peak 28 Vrms DUAL COUNT MODES When any dual count mode is used then User Inputs and or 2 will accept the second signal of each signal pair The user inputs do not have the Logic Mag HI LO Freq and Sink Source input setup switches The user CE USER INPUTS Three programmable use