Home

ONYX-1722_1922 manual 0310_2nd ED_

image

Contents

1. User Address Description Address 000 01F DMA Controller 1 000 000F 020 03F Interrupt Controller 1 Master 020 021 040 05F System Time 040 043 060 06F 8042 Keyboard Controller 060 064 070 07F Real time Clock NMI non maskable 070 073 Interrupt Mask 080 09F DMA Page Register 080 08F OAO 0BF Interrupt Controller 2 0A0 0A1 0CO 0DF DMA Controller 2 0CO 0DF OFO OFF Math Coprpcessor OFO OFF 170 177 Secondary IDE Channel 170 177 1F0 1F7 Primary IDE Channel 1F0 1F7 2F8 2FF Serial Port 2 2F8 2FF 378 37F Parallel Printer Port 1 378 37F 3B0 3DF EGA VGA card 3B0 3DF 3F8 3FF Serial Port 1 3F8 3FF B 2 Memory Address Map Memory Address Description 00000 9FFFF System memory A0000 BFFFF VGA buffer C0000 CFFFF VGA BIOS E0000 FFFFF System BIOS Appendix B I O Information B 2 Slim Medical Panel PC ONYX 1722 1922 B 3 IRQ Mapping Chart IRQO System Timer IRQ8 System CMOS Real time clock IRQ1 Keyboard IRQ9 Microsoft ACPI Compliant system IRQ2 Cascade to IRQ10 Unused IRQ Controller IRQ3 COM2 IRQ11 Unused IRQ4 COM1 IRQ12 PS 2 mouse IRQ5 Unused IRQ13 FPU IRQ6 Unused IRQ14 Primary IDE IRQ7 Printer IRQ15 Secondary IDE B 4 DMA Channel Assignments DMA Function Channel 0 Available Available Unused Available Direct Memory Access Controller Available Available Availab
2. ONYX 1922SD T Al Version Chapter 2 Hardware Installation 2 4 Slim Medical Panel PC ONYX 1722 1922 ONYX 1922 DT T A3 Version Figure 2 2 Rear view ofthe Slim Medical Panel PC Chapter 2 Hardware Installation 2 5 Slim Medical Panel PC ONYX 1722 1922 2 3 Removing the rear maintenance cover Pull USB cover Unscrew the attachment screws used to hold the rear maintenance cover and remove rear cover 2 4 VESA Mounting Holes VESA Screws M4 x 0 7 x 20mm FE m M HE VESA 100 VESA 75 N 9 ONYX 1722 VESA 75 Pi E MU ii en VESA 100 VESA 75 ONYX 1922 VESA 75 Chapter 2 Hardware Installation 2 6 Smart Hoanncaro y Slim Medical Panel PC ONYX 1722 1922 2 5 Hard Disk Drive HDD Installatio 1 Uns FAZ ar 3 Assemble 2 5 HDD into disk module Slim Medical Panel PC ONYX 1722 1922 Chapter 2 Hardware Installation 2 8 Slim Medical Panel PC ONYX 1722 1922 Chapter Award BIOS Setup Chapter3 Award BIOS Setup 3 1 Slim Medical Panel PC ONYX 1722 1
3. oooo oo 2 2 2 2 A Quick Tour of the ONYX 1722 1922 2 3 2 3 Removing the rear maintenance cover 2 6 2 4 VESA Mounting Holes eene 2 6 2 5 Hard Disk Drive HDD Installation 2 7 Chapter 3 Award BIOS Setup 3 1 System Test and Initialization 3 2 3 2 Award BIOS Setup mma 3 3 Chapter 4 Driver Installation 4 1 Installation oooooooooooo oo Wo 4 3 Appendix A Programming the Watchdog Timer AA PrograMMing aa A 2 A 2 ITE8712 Watchdog Timer Initial Program A 6 Appendix B I O Information B 1 I O Address Map oom ma B 2 Slim Medical Panel PC ONYX 1722 1922 B 2 Memory Address Map e B 2 B 3 IRQ Mapping Chart oooo on B 3 B 4 DMA Channel Assignments e B 3 Appendix C Miscellanea C 1 General Cleaning TipS om C 2 C 2 Cleaning Tools oooooooo Woman C 3 C 3 Scrap Computer Recycling C 5 Slim Medical Panel PC ONYX 1722 1922 Chapter General Information Slim Medical Panel PC ONYX 1722 1922 1 1 Introduction The ONYX 1722 1922 is a Slim Medical Panel PC with Intel CoreTM 2 Duo ULV Celeron M processor based computer that is designed to serve as a point of care station It is a PC
4. 90W max MTBF 100 000 hrs operation at 25 C Environmental Specifications Operating Temperature 0 C to 40 C 32 F 104 F Storage Temperature 20 C to 60 C 4 F 140 F Storage Humidity 5 to 95 40 C non condensing Vibration 0 5G 5 500Hz Random operation Shock 15G peak acceleration 11 msec duration operation Drop 76cm 1 Corner 3 Edge 6 Surface EMI Safety CE FCC Class B UL 60601 1 EN 60601 1 Noise Zero noise Input Power Rating 1 FSP PMP120 14 yyy 100 240 Vac 47 63Hz 1 4 0 6A 2 FSP PMP90 14 yyy 100 240 Vac 47 63 Hz 1 06 0 45A Chapterl General Information 1 5 Slim Medical Panel PC ONYX 1722 1922 TouchScreen Optional Type 5 wire Analog Resistive Interface USB Interface Resolution 2048 x 2048 Light Transmission gt 80 2 Life Time 36 million times Chapterl General Information 1 6 Slim Medical Panel PC ONYX 1722 1922 1 4 Dimension ONYX 1722 A1 Version Ann i rr ee W fo g me TRE E o o E N Unit mm Chapterl General In
5. IO YO write to 2Eh Any other I O transition cycle Is the data 87h Y r Check Pass key YO write to 2Eh N Next Data Last Data Any other I O transition cyck Y MB PnP Mode There are three steps to complete the configuration setup 1 Enter the MB PnP Mode 2 Modify the data of configuration registers 3 Exit the MB PnP Mode Undesired result may Appendix A Programming the Watchdog Timer A 2 Slim Medical Panel PC ONYX 1722 1922 occur if the MB PnP Mode is not exited normally 1 Enter the MB PnP Mode To enter the MB PnP Mode four special I O write operations are to be performed during Wait for Key state To ensure the initial state of the key check logic it is necessary to perform four write opera tions to the Special Address port 2EH Two different enter keys are provided to select configuration ports 2Eh 2Fh of the next step Address Port Data Port 87h 01h 55h 55h 2Eh 2Fh 2 Modify the Data of the Registers All configuration registers can be accessed after entering the MB PnP Mode Before accessing a selected register the content of Index 07h must be changed to the LDN to which the register belongs except some Global registers 3 Exit the MB PnP Mode Set bit 1 of the configure control register Index 02h to 1 to exit the MB PnP Mode WatchDog Timer Configuration Registers LDN Index R W Reset Configuration Register or Action All 02H W N
6. Initial CLC RET Check Chip ENDP Read Configuration Data PROC NEAR Appendix A Programming the Watchdog Timer A 8 ony Slim Medical Panel PC ONYX 1722 1922 MOV DX WORD PTR CS Cfg Port 04h OUT DX AL MOV DX WORD PTR CS Cfg Port 06h IN AL DX RET Read_Configuration_Data ENDP Write_Configuration_Data PROC NEAR MOV DX WORD PTR CS Cfg_Port 04h OUT DX AL XCHG AL AH MOV DX WORD PTR CS Cfg Port 06h OUT DX AL RET Write Configuration Data ENDP Superio Set Reg proc near push ax MOV DX WORD PTR CS Cfg Port 04h mov al cl out dx al pop ax inc dx out dx al Appendix A Programming the Watchdog Timer A 9 ony Slim Medical Panel PC ONYX 1722 1922 ret Superio_Set_Reg endp Set_Logic_Device proc near Set_Logic_Device proc near push ax push cx xchg al cl mov cl 07h call Superio_Set_Reg pop cx pop ax ret Set_Logic_Device endp Select 02Eh gt Index Port 02Fh gt Data Port Cfg_Port DB 087h 001h 055h 055h DW 02Eh 02Fh END Main Note Interrupt level mapping OFh Dh not valid OCh IRQ12 03h IRQ3 Appendix A Programming the Watchdog Timer A 10 ony Slim Medical Panel PC ONYX 1722 1922 02h not valid 01h IRO1 00h no interrupt selected Appendix A Programming the Watchdog Timer A 11 Slim Medical Panel PC ONYX 1722 1922 Appendix I O Information Appendix B I O Information B 1 ony Slim Medical Panel PC ONYX 1722 1922 B 1 I O Address Map
7. PC AT PS 2 are trademarks of International Business Machines Corporation e Microsoft Windows is a registered trademark of Microsoft Corporation e HILisa trademark of Realtek Semi Conductor Co Ltd e C amp T is a trademark of Chips and Technologies Inc e UMC is a trademark of United Microelectronics Corporation e ITE is a trademark of Integrated Technology Express Inc All other product names or trademarks are properties of their respective owners Slim Medical Panel PC ONYX 1722 1922 Packing List Before you begin installing your Medical Station please make sure that the following items have been shipped m ONYX 1722 or ONYX 1922 Medical Station m HDD screws VESA Screws M4 x 0 7 x 20mm m Utility CD ROM Please insert the ONYX 1722 1922 CD ROM into external CD ROM drive which Contains User s Manual in PDF format Drivers and Utilities If any of these items are missing or damaged you should contact your distributor or sales representative immediately Headquarters Onyx Healthcare Inc 2F No 135 Lane 235 Pao Chiao Rd Hsin Tien City Taipei 231 Taiwan R O C TEL 886 2 8919 2188 FAX 886 2 8919 1699 E mail sales onyx healthcare com http www onyx healthcare com Slim Medical Panel PC ONYX 1722 1922 Worldwide Offices Onyx Healthcare USA Inc 2663 Saturn street Brea CA 92821 USA Tel 1 714 996 1800 Fax 1 714 996 1811 Email usasales onyx healthcare com Onyx Hea
8. Value Register Index 73h Default 00h Bit Description 7 0 WDT Time out value 7 0 Appendix A Programming the Watchdog Timer A 5 Slim Medical Panel PC ONYX 1722 1922 A 2 ITE8712 Watchdog Timer Initial Program MODEL SMALL CODE Main CALL Enter Configuration mode CALL Check Chip mov cl 7 call Set Logic Device time setting mov cl 10 10 Sec decal Watch_Dog_Setting Timer setting mov al cl mov cl 73h call Superio_Set_Reg Clear by keyboard or mouse interrupt mov al OfOh mov cl 71h call Superio Set Reg unit is second mov al OCOH mov cl 72h call Superio Set Reg Appendix A Programming the Watchdog Timer A 6 ony Slim Medical Panel PC ONYX 1722 1922 game port enable mov cl 9 call Set_Logic_Device Initial_OK CALL Exit_Configuration_mode MOV AH 4Ch INT 21h Enter Configuration Mode PROC NEAR MOV SI WORD PTR CS Offset Cfg Port MOV DX 02Eh MOV CX 04h Init 1 MOV AL BYTE PTR CSIISIJ OUT DX AL INC SI LOOP Init 1 RET Enter Configuration Mode ENDP Exit Configuration Mode PROC NEAR MOV AX 0202h Appendix A Programming the Watchdog Timer A 7 ony Slim Medical Panel PC ONYX 1722 1922 CALL Write Configuration Data RET Exit Configuration Mode ENDP Check Chip PROC NEAR MOV AL 20h CALL Read Configuration Data CMP AL 87h JNE Not Initial MOV AL 21h CALL Read Configuration Data CMP AL 12h JNE Not Initial Need Initial STC RET Not
9. based system with 17 19 true color TFT LCD display Zero Noise solution integrated multimedia functions make them the perfect platforms to build comprehensive lifestyle computing applications The ONYX 1722 1922 includes all the features of a powerful computer into a slim and attractive chassis Both of the ONYX 1722 has 380 nits and ONYX 1922 has 300 nits TFT displays with 1280 x 1024 resolution and with 17 and 19 LCD respectively Integrating with high brightness LCD is easier to analyze DICOM images These two models support 2 5 Hard Disk Drive storage function and one Mini PCI for WLAN expansion Moreover they feature flexible I O ports such as six USB2 0 one RS 232 one 10 100Base TX one PS 2 keyboard mouse and two speakers Convenient operation Silent compact mobility and highly integrated multimedia system let you to focus on healthcare utility interactive information displays automation control systems general desktop usage multimedia recreation and other medical requirements Chapterl General Information 1 1 Slim Medical Panel PC ONYX 1722 1922 1 2 Features e 17 19 SXGA Color TFT LCD Display e Easy To Use Compact Simple Design e Fanless Zero Noise e 1000 1 Contrast Wide View Angle For X Ray Film ONYX 1722 e 2000 1 Contrast Wide View Angle For X Ray Film ONYX 1922 e X 380 Nits High Brightness For X Ray Film ONYX 1722 e 300 Nits High Brightness For X Ray Film ONYX 1922 e
10. 922 3 1 System Test and Initialization These routines test and initialize board hardware If the routines encounter an error during the tests you will either hear afew short beeps or see an error message on the screen There are two kinds of errors fatal and non fatal The system can usually continue the boot up seguence with non fatal errors Non fatal error messages usually appear on the screen along with the following instructions Press lt F1 gt to RESUME Write down the message and press the F1 key to continue the boot up sequence System configuration verification These routines check the current system configuration against the values stored in the CMOS memory Ifthey do not match the program outputs an error message You will then need to run the BIOS setup program to set the configuration information in memory There are three situations in which you will need to change the CMOS settings 1 You are starting your system for the first time 2 You have changed the hardware attached to your system 3 The CMOS memory has lost power and the configuration information has been erased The ONYX 1722 1922 CMOS memory has an integral lithium battery backup for data retention However you will need to replace the complete unit when it finally runs down Chapter3 Award BIOS Setup 3 2 Slim Medical Panel PC ONYX 1722 1922 3 2 Award BIOS Setup Awards BIOS ROM has a built in Setup program that allows users to m
11. A Configure Control 07H71H RW 00H WatchDog Timer Control Register 07H 72H RW 00H WatchDog Timer Configuration Regis ter 07H 73H RW 00H WatchDog Timer Time out Value Register Appendix A Programming the Watchdog Timer 4 3 Slim Medical Panel PC ONYX 1722 1922 Configure Control Index 02h This register is write only Its values are not sticky that is to say a hardware reset will automatically clear the bits and does not require the software to clear them Bit Description 7 2 Reserved 1 Returns to the Wait for Key state This bit is used when the configuration sequence is completed 0 Resets all logical devices and restores configuration registers to their power on states WatchDog Timer Control Register Index 71h Default 00h Bit Description WDT is reset upon a CIR interrupt WDT is reset upon a KBC mouse interrupt WDT is reset upon a KBC keyboard interrupt WDT is reset upon a read or a write to the Game Port base address 3 2 Reserved 1 Force Time out This bit is self clearing 0 WDT Status 1 WDT value reaches 0 0 WDT value is not 0 WatchDog Timer Configuration Register Index 72h Default 0 Appendix A Programming the Watchdog Timer A 4 Slim Medical Panel PC ONYX 1722 1922 Bit Description 7 WDT Time out value select 1 Second 0 Minute 6 WDT output through KRST pulse enable 5 4 Reserved 3 0 Select the interrupt level for WDT WatchDog Timer Time out
12. Intel Core 2 Duo ULV Processor e Resistive Touchscreen Optional e 802 11a b g n Wireless Antenna Optional e Weight 5 6 Kg Thickness 69 mm ONYX 1722 e Weight 6 0 Kg Thickness 69 5 mm ONYX 1922 Chapterl General Information 1 2 Slim Medical Panel PC ONYX 1722 1922 1 3 Specification Hardware Specifications ONYX 1722 17 SXGA color TFT LCD ONYX 1922 19 SXGA color TFT LCD System 200 pin DDRII SODIMM x 1 Max 2GB Memory CPU Board Intel Core 2 Duo U series Processor A1 Version Display Intel Celeron M 1 86GHz A3 Version Drive Bay 12 5 Hard Disk Drive SATA Expansion Mini PCI x 1 Button Brightness Sound Power SW lo USB 2 0 x 4 RS 232 x 1 1 Isolation RS 232 A1 Version USB 2 0 x 6 RS 232 x 1 A3 Version 10 100 1000 Base TX x 1 PS 2 keyboard mouse x 1 Speaker x 2 2W LCD Specifications Model Name ONYX 1722 series ONYX 1922 series Display Type 17 color TFT LCD 19 color TFT LCD Max Resolution 1280 x 1024 1280 x 1024 Max Colors 16 7M 16 2M Dot Size mm 0 264 x 0 264 0 294 x 0 294 Luminance cd m2 1380 TYP 300 TYP Viewing Angle 170 H 178 H 170 V 178 V Chapterl General Information 1 3 Slim Medical Panel PC ONYX 1722 1922 Contrast Ratio 1000 1 2000 1 Brightness Control Yes Yes Back Light MTBF 50 000 Hr
13. Slim Medical Panel PC ONYX 1722 1922 ONYX 1722 1922 17 19 Intel Core 2 Duo Celeron Processor High Brightness Slim Medical Panel PC ONYX 1722 1922 Manual A1 A3 Version March 2011 Slim Medical Panel PC ONYX 1722 1922 Copyright Notice This document is copyrighted 2011 All rights are reserved The original manufacturer reserves the right to make improvements to the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use nor for any infringements upon the rights of third parties which may result from its use The material in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to assure its accuracy ONYX assumes no liabilities resulting from errors or omissions in this document or from the use of the information contained herein ONYX reserves the right to make changes in the product design without notice to its users Slim Medical Panel PC ONYX 1722 1922 Acknowledgments e _ Intel Core 2 Duo Celeron are registered trademarks of Intel Corporation e IBM
14. dden rush of power can damage sensitive electronic components Always ground yourself to remove any static Caution charge before touching the board Modern electronic devices are very sensitive to static ag electric charges Use a grounding wrist strap at all times Place all electronic components on a static dissipative surface or in a static shielded bag when they are not in the chassis Chapter 2 Hardware Installation 2 2 Slim Medical Panel PC ONYX 1722 1922 2 2 A Quick Tour ofthe ONYX 1722 1922 Before you start to set up the ONYX 1722 1922 take a moment to become familiar with the locations and purposes of the controls drives connections and ports which are illustrated in the figures below When you place the ONYX 1722 1922 upright on the desktop its front panel appears as shown in Picture 2 1 Picture 2 1 Front View of the Slim Medical Panel PC When you turn the Slim Medical Panel PC around and look at its rear cover the sunken I O section is at the bottom of the PC as shown in Picture 2 2 The I O section includes various I O ports including DC in Serial ports VGA PS2 Ethernet USB Only assemble with the Mini PCI capture card The Slim Medical Panel PC integrates with WLAN function by using Mini PCI Chapter 2 Hardware Installation 2 3 Slim Medical Panel PC ONYX 1722 1922 00 o
15. e cleaning your computer or computer peripherals Keep in mind that some components in your computer may only be able to be cleaned using a product designed for cleaning that component if this is the case it will be mentioned in the cleaning tips e Cloth A piece of cloth is the best tool to use when rubbing up a component Although paper towels or tissues can be used on most hardware as well we still recommend you to rub it with a piece of cloth e Water or rubbing alcohol You may moisten a piece of cloth a bit with some water or rubbing alcohol and rub it on the computer Unknown solvents may be harmful to the plastics parts e Vacuum cleaner Absorb the dust dirt hair cigarette particles and other particles out of a computer can be one of the best methods of cleaning a computer Over time these items can restrict the airflow in a computer and cause circuitry to corrode Appendix C Miscellanea C 3 Slim Medical Panel PC ONYX 1722 1922 e Cotton swabs Cotton swaps moistened with rubbing alcohol or water are excellent tools for wiping hard to reach areas in your keyboard mouse and other locations e Foam swabs Whenever possible it is better to use lint free swabs such as foam swabs Note We strongly recommended that you should shut down the system before you start to clean any single components Please follow the steps below Close all application programs Close operating software Turn off powe
16. formation 1 7 Slim Medical Panel PC ONYX 1722 1922 ONYX 1922 A1 Version AT lv O Rb IN h Unit mm n Chapterl General Information 1 8 Slim Medical Panel PC ONYX 1722 1922 ONYX 1722 A3 Version il Unit mm Chapterl General Information 1 9 Slim Medical Panel PC ONYX 1722 1922 ONYX 1922 A3 Version 443 99 210 210 PN 169 88 HA Ill Chapterl General Information 1 10 18012 Unit mm Slim Medical Panel PC ONYX 1722 1922 Chapter Hardware Installation Chapter 2 Hardware Installation 2 1 Onyx Slim Medical Panel PC ONYX 1722 1922 2 1 Safety Precautions Warning Always completely disconnect the power cord from your board whenever you are working on it Do not make connections while the power is on because a su
17. ical equipment with respect to electric ox Ue shock fire and mechanical hazards only in C US accordance with UL 60601 1 and CAN CSA C22 2 NO 601 1 Attention consult ACCOMPANYING DOCUMENTS E Ground wire Protective Ground wire c Aus Medical equipment with respect to electric shock fire and mechanical hazards only in accordance with UL 60601 1 and CAN CSA C22 2 NO 601 1 TYPE B APPLIED PART Slim Medical Panel PC ONYX 1722 1922 Below Table for China RoHS Requirements EMPA BA YAN TAZIONE E ONYX Panel PC Workstation ABHENMARTER EIER 6 K 8 NAS SAE SAZER Pb Hg Cd Cr VI PBB PBDE EL EES AR x O O O O O EGET HEER x O O O O O as RM HR x O O O O O FE x O O O O O BREDERE TER X O O O O O BUE x O O O O O IRR X O O O O O Pa x O O O O O SUR X O O O O O O RAZARA EEE BAHR SUIT 11363 2006 EM EN EERU X KRAFT AMA EAR SAMEN EE SJIT 11363 2006 FRERE E bener ARE AIR JSTERE BEBE T ERAM AR RAS gt EDER ERR CRE BRA Slim Medical Panel PC ONYX 1722 1922 Contents Chapter 1 General Information 1 1 Introduction ban an maen na aa hahaa 1 1 1 2 Features Jin an an an an ana 1 2 1 3 Specification uii iuuininininiainuns 1 3 1 4 Dimension ceteee cece dana cute dana cire ciii dasi 1 6 Chapter 2 Hardware Installation 2 1 Safety Precautions
18. ile AWARD has designated the custom BIOS to maximize performance the factory has the right to change these defaults to meet their needs Set Supervisor User Password Use this menu to set Supervisor User Passwords Save and Exit Setup Save CMOS value changes to CMOS and exit setup Exit Without Saving Abandon all CMOS value changes and exit setup Chapter3 Award BIOS Setup 3 4 Slim Medical Panel PC ONYX 1722 1922 For more detailed information you can refer to the ONYX BIOS Item Description pdf file in the CD for the meaning of each setting in this chapter Chapter3 Award BIOS Setup 3 5 Slim Medical Panel PC ONYX 1722 1922 Chapter Installation Chapter 4 Driver Installation 4 1 Slim Medical Panel PC ONYX 1722 1922 The ONYX 1722 1922 comes with an AutoRun CD ROM that contains all drivers and utilities that can help you to install the driver automatically Insert the driver CD the driver CD title will auto start and show the installation guide If not please follow the seguence below to install the drivers Follow the seguence below to install the drivers Step 1 Install Intel INF Driver Step 2 Install Intel VGA Driver Step 3 Install Intel LAN Driver Step 4 Install Realtek Audio Driver Step 5 Install Touch Driver Optional USB 2 0 Drivers are available for download using Windows Update for both Windows XP and Windows 2000 For additional information regarding USB 2 0 s
19. l electrical systems Eguipment not complying with UL 60601 1 shall be kept outside the patient environment as defined in the standard Caution It may cause the danger of explosion if battery is incorrectly replaced Replace only with same or eguivalent type recommended by the manufacturer Slim Medical Panel PC ONYX 1722 1922 Classification 1 Degree of production against electric shock Not classified TYPE B APPLIED PART for Isolation card function RS 232 2 Degree of protection against the ingress of water IPXO 3 Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide 4 Mode of operation Continuous 5 Type of protection against electric shock Class equipment Slim Medical Panel PC ONYX 1722 1922 FCC This device complies with Part 15 FCC Warning Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Slim Medical Panel PC ONYX 1722 1922 UL Module Description oS ie C US Onyx 1722 1922 AC modules are developed to suitable for the Classification Mark reguirement Slim Medical Panel PC ONYX 1722 1922 Safety Symbol Description The following safety symbols are the further explanations for your reference ss Med
20. le l O O1 o In Appendix B I O Information B 3 Slim Medical Panel PC ONYX 1722 1922 Appendix Miscellanea Appendix C Miscellanea C 1 Slim Medical Panel PC ONYX 1722 1922 C 1 General Cleaning Tips You may need the following precautions before you begin to clean the computer When you clean any single part or component for the computer please read and understand the details below fully 1 Never spray or squirt the liquids directly onto any computer component If you need to clean the device please rub it with a piece of dry cloth 2 Be cautious of the tiny removable components when you use a vacuum cleaner to absorb the dirt on the floor 3 Turn the system off before you start to clean up the component or computer 4 Never drop the components inside the computer or get circuit board damp or wet 5 Be cautious of all kinds of cleaning solvents or chemicals when you use it for the sake of cleaning Some individuals may be allergic to the ingredients 6 Try notto put any food drink or cigarette around the computer Appendix C Miscellanea C 2 Slim Medical Panel PC ONYX 1722 1922 C 2 Cleaning tools Although many companies have created products to help improve the process of cleaning your computer and peripherals users can also use household items to clean their computers and peripherals Below is a listing of items you may need or want to use whil
21. lthcare EUROPE B V Ekkersrijt 4002 5692 DA Son The Netherlands Tel 31 0 499 462020 Fax 31 0 499 462010 Email eusales onyx healthcare com Onyx Healthcare Technology GmbH An der Trift65d 63303 Dreieich Germany TEL 49 0 61033 7479 00 Fax 49 0 61033 7479 49 Email eusales onyx healthcare com Slim Medical Panel PC ONYX 1722 1922 Onyx Healthcare Nanjing INC Room 1318 Metallurgy Building East Zhongshan Road Nanjing China Tel 86 025 58859841 Fax 86 025 85088070 Email Jonwang onyx healthcare com Onyx Healthcare Singapore PTE LTD 57 Genting Lane 07 00 Singapore 349564 Tel 65 67498749 Fax 65 67461595 Email sgsales onyx healthcare com Slim Medical Panel PC ONYX 1722 1922 Safety amp Warranty 10 11 12 13 Read these safety instructions carefully Keep this user s manual for later reference Disconnect this equipment from any AC outlet before cleaning Do not use liquid or spray detergents for cleaning Use a damp cloth For pluggable equipment the power outlet must be installed near the equipment and must be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall could cause damage The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS Make sure the voltage of the power source is correct bef
22. odify the basic system configuration This type of information is stored in battery backed CMOS RAM so that it retains the Setup information when the power is turned off Entering setup Power on the computer and press lt Del gt immediately This will allow you to enter Setup Standard CMOS Features Use this menu for basic system configuration Date time IDE etc Advanced BIOS Features Use this menu to set the advanced features available on your system Advanced Chipset Features Use this menu to change the values in the chipset registers and optimize your system performance Integrated Peripherals Use this menu to specify your settings for integrated peripherals Primary slave secondary slave keyboard mouse etc Power Management Setup Use this menu to specify your settings for power management HDD power down power on by ring etc Chapter3 Award BIOS Setup 3 3 Slim Medical Panel PC ONYX 1722 1922 PnP PCI Configurations This entry appears if your system supports PnP PCI PC Health Status This menu shows you the status of PC Frequency Voltage Control This menu shows you the display of frequency Voltage Control Load Fail Safe Defaults Use this menu to load the BIOS default values for the minimal stable performance for your system to operate Load Optimized Defaults Use this menu to load the BIOS default values that are factory settings for optimal performance system operations Wh
23. or your operating system and double click on Setup exe file 2 Follow the instructions that the window shows 3 The system will help you install the driver automatically Step 5 Install Touch Panel Driver 1 Click on the Touch folder and and select the 2kXP v5 6 0 6806 folder and double click on the setup exe for A1 version 2 Click on the Touch folder and and select the PenMount Windows Universal Driver V2 2 0 283 folder and double click on the setup exe for A3 version Follow the instructions that the window shows The system will help you install the driver automatically Chapter 4 Driver Installation 4 4 Slim Medical Panel PC ONYX 1722 1922 Appendix Programming the Watchdog Timer Appendix A Programming the Watchdog Timer A 1 ony Slim Medical Panel PC ONYX 1722 1922 A 1 Programming ONYX 1722 1922 utilizes ITE 8712 chipset as its watchdog timer controller Below are the procedures to complete its configuration and the ONYX intial watchdog timer program is also attached based on which you can develop customized program to fit your application Configuring Sequence Description After the hardware reset or power on reset the ITE 8712 enters the normal mode with all logical devices disabled except KBC The initial state enable bit of this logical device KBC is determined by the state of pin 121 DTR1 at the falling edge of the system reset during power on reset Hardware Reset Wait for key string
24. ore connecting the equipment to the power outlet Position the power cord so that people cannot step on it Do not place anything over the power cord All cautions and warnings on the equipment should be noted If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient over voltage Never pour any liquid into an opening This could cause fire or electrical shock Never open the equipment For safety reasons only qualified Slim Medical Panel PC ONYX 1722 1922 service personnel should open the equipment 14 If any of the following situations arises get the equipment checked by service personnel The power cord or plug is damaged a b Liquid has penetrated into the equipment 9 The equipment has been exposed to moisture d The equipment does not work well or you cannot get it to work according to the users manual e The equipment has been dropped and damaged f The equipment has obvious signs of breakage 15 DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 C 4 F OR ABOVE 60 C 140 F IT MAY DAMAGE THE EQUIPMENT 16 External equipment intended for connection to signal input output or other connectors shall comply with relevant UL IEC standard e g UL 1950 for IT equipment and UL 60601 1 IEC 60601 series for systems shall comply with the standard IEC 60601 1 1 Safety reguirements for medica
25. r switch Remove all device a FF wn gt Pull out power cable Appendix C Miscellanea C 4 Slim Medical Panel PC ONYX 1722 1922 C 3 Scrap Computer Recycling If the computer equipments need the maintenance or are beyond repair we strongly recommended that you should inform us as soon as possible for the suitable solution For the computers that are no longer useful or work well please contact with worldwide distributors for recycling The worldwide distributors show on the following website http www onyx healthcare com tw Contact php Note Follow the national requirements to dispose unit Appendix C Miscellanea C 5
26. s 50 000 Hrs Note All ONYX s LCD products are manufactured with High precision technology However there are a small number of defective pixels in all LCD panels that are not able to change color This is a normal occurrence for all LCD displays from all manufacturers and should not be noticeable or objectionable under normal operation ONYX LCD panels are qualified for industry standard conditions in the following total 7 dead pixels on a screen or if there are 3 within 1 inch square area of each other on the display Mechanical Specifications Architecture Close frame Front Bezel Plastic bezel with resistive touch screen Color White Mounting Holder VESA 75 100mm Construction 3mm ABS PC TYPE Plastic housing Dimension ONYX 1722 17 4 x 14 9 x 2 8 422mm x 379mm x 69 5mm W x H x D ONYX 1922 13 52 x 14 9 x 2 8 338mm x 383mm x 70mm ONYX 1722 12 32 Ib 5 6 kg ONYX 1922 14 3 Ib 6 5 kg ONYX 1722 15 62 Ib 7 1 kg ONYX 1922 18 4 Ib 8 2 kg Packing Filler PE Net Weight Gross Weight Chapterl General Information 1 4 Slim Medical Panel PC ONYX 1722 1922 Power Supply Specifications Power Requirement DC 9 30V Input Voltage 1 FSP PMP120 14 yyy 100 240 Vac 47 63Hz 1 4 0 6A 2 FSP PMP90 14 yyy 100 240 Vac 47 63 Hz 1 06 0 45A Output Voltages 1 FSP PMP120 14 yyy 24V 5A 120W max 2 FSP PMP90 14 yyy 24V 3 75A
27. upport in Windows XP and Windows 2000 please visit www microsoft com hwdev usb Please read instructions below for further detailed installations Chapter 4 Driver Installation 4 2 Slim Medical Panel PC ONYX 1722 1922 41 Installation Insert the ONYX 1722 1922 CD ROM into the CD ROM drive And install the drivers from Step 1 to Step 5 in order Step 1 Install Intel INF Driver 1 Click on the Step 1 Intel Inf Driver folder and double click on the infins911autol exe 2 Follow the instructions that the window shows 3 The system will help you install the driver automatically Step 2 Install Intel VGA Driver 1 Click on the Step 2 VGA driver folder and select the corresponding folder for your operating system and double click on Setup exe file 2 Follow the instructions that the window shows 3 The system will help you install the driver automatically Step 3 Install Intel LAN Driver 1 Click on the Step 3 LAN driver folder and select the Winx32 folder and double click on exe for x86 32bit OS if the OS is Windows 64bit OS please select the Winx64 folder and double click on exe file 2 Follow the instructions that the window shows Chapter 4 Driver Installation 4 3 Slim Medical Panel PC ONYX 1722 1922 3 The system will help you install the driver automatically Step 4 Install Audio Driver 1 Click on the Step 4 AUDIO driver folder and select the corresponding folder f

Download Pdf Manuals

image

Related Search

Related Contents

Manual de Utilização  MAI - JUIN - Bibliothèque municipale de Lyon  NeoCitran rhume et grippe nuit  Chamberlain 4200 1/2HP Garage Door Opener User Manual  Ask Proxima DP6800 User's Manual  intext:Betriebsanleitung filetype:pdf  Anexo I - Portal Eletrobras Distribuição Roraima  P.O.F. 2014-2015 - Istituto Comprensivo Loiri Porto San Paolo (OT)  NCP Software User`s Manual for L Connection Network  ShelterLogic 90469 Use and Care Manual  