Home
Quick Start Guide
Contents
1. Division 2 et conform ment a l autorit comp tente Cet equipement est adapt pour une utilisation en Classe1 Division 2 Groupes A B C et D ou endroits non dangereux seulement AVERTISSEMENT RISQUE D EXPLOSION LA SUBSTITUTION DE TOUT COMPOSANT PEUT NUIRE A LA CONFORMITE DE CLASSE DIVISION 2 AVERTISSEMENT RISQUE D EXPLOSION LORSQUE DANS DES ENDROITS DANGEREUX DEBRANCHEZ LE CORDON D ALIMENTATION AVANT DE REMPLACER OU DE BRANCHER LES MODULES AVERTISSEMENT RISQUE D AVERTISSEMENT NE DEBRANCHEZ PAS L EQUIPEMENT PENDANT QUE LE CIRCUIT EST DIRECT OU A MOINS QUE L ENVIRONNEMENT SOIT CONNU POUR ETRE LIBRE DE CONCENTRATIONS INFLAMMABLES FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference to radio communications in which case the user will be required to correct the interference at their own expense Warning Changes or modifications to this unit not expressly approved
2. signal is stronger OFF Very weak or no signal less than 100dBm WAN OFF Cellular connection is not established ON Cellular connection is established no network data activity FLASH Cellular connection is established with network data activity RS232 ON Link established with serial device but no data activity FLASH Data transmitted received with attached serial device Ethernet ON Link established with Ethernet device FLASH Data transmitted received Red Lion Controls 20 Willow Springs Circle York PA 17406 QUICK START GUIDE IndustrialPro SN 6000 Router GSM CDMA HSPA and LTE INSTALLATION AND HAZARDOUS AREA WARNINGS All power input and output I O wiring must be in accordance with Class Division 2 wiring methods are in accordance with the authority having jurisdiction This equipment is suitable for Use in Class 1 Division 2 Groups A B C and D or Non Hazardous Locations Only WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I DIVISION 2 WARNING EXPLOSION HAZARD WHEN IN HAZARDOUS LOCATIONS DISCONNECT POWER BEFORE REPLACING OR WIRING UNITS WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS AVERTISSEMENTS POUR INSTALLATION ET ENDROITS DANGEREUX Tout pouvoir le cablage d entr e et de sortie I O doivent tre conformes aux m thodes de cablage de Classe
3. IndustrialPro SN 6000 Router GSM CDMA HSPA and LTE 3 QUICK START GUIDE red lon UNPACKING INSTRUCTIONS EJ Please allow 2 4 minutes for the unit to recognize the cellular data card and connect to the cellular network When this has occurred the Signal Strength LEDs should light up see table on back If signal strength is not lit or flashes slowly please refer to the User Manual at www sixnet com FEM Unpack the Red Lion unit and verify the following components are enclosed for the IndustrialPro Router Figure A Figure A Package Contents SN RAM 6XXxX SN RAM 6X00 AC adapter with Connect to the Ethernet RJ45 port for network connectivity either barrel connector AC or Molex ACCESSSING THE GRAPHICAL USER INTERFACE GUI MX or 15ft Molex cable DC can be ordered in a kit ie SN 6600 XX AC EW Connect PC to the IndustrialPro Router DC or MX or ordered separately con eHemoravalanle Connect a CAT 5 Ethernet cable between the local PC and SN RAM 6X01 4 pin plug with screw the unit s Ethernet port Verify the link LED is lit terminals to connect to an external DC power source Available with AC IEJ Setup PC IP Address adapter with barrel connector AC For assistance with configuring your PC see the appropriate SN RAM 6X21 4 pin plug with screw terminals to connect to an external Microsoft Windows support webpage listed at DC power source Available with AC http support mi
4. as GREEN bars populated If you see any RED bars represented under Signal Strength please consult the User Manual Ethernet Eth0 should show Up and show the network issued IP address NOTE For SIM based models if Unavailable and connection Unknown browse to the Network Tab gt Cellular Connection gt Configuration and input the APN in the field labeled Enter APN input username and password in appropriate fields if supplied by your cellular carrier If you are unable to confirm this status on the Main page please refer to the SN 6000 User Guide for troubleshooting steps at www sixnet com For more information on setting up Modbus features please refer to the Software User Guide available at www sixnet com If you are able to confirm this status then your unit is successfully connected to the cellular network RED LION WIRELESS TECHNICAL SUPPORT If you have followed all of the instructions up to this point have verified with your carrier that you are not having an authentication problem have verified that you have adequate cellular signal reception and your unit is still not communicating then it is time to contact Red Lion Wireless Technical Support at support redlion net or 1 877 432 9908 and we will be happy to assist you in getting your unit operational HARDWARE STATUS LEDS LED State Description Power ON Power is applied to the router Signal ON Excellent signal strength FLASH Flashes faster as
5. by the party responsible for compliance could void the user s authority to operate the equipment Information to the user If this equipment causes interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures In order to meet FCC emissions limits this equipment must be used only with cables that comply with IEEE 802 3 If necessary the user should consult the dealer or an experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems www redlion net
6. crosoft com adapter with barrel connector AC d Antennas sold separately PC to Ethernet Interfaces Select Use the following IP address and fill in the blank l l fields with the information below EJ Contact your cellular provider carrier and request a data account For CDMA models SN RAM 66XX give the ESN Ethernet 0 number of the router to the carrier to activate the data IP address 192 163 02 account For GSM HSPA and LTE models SN RAM 64XX Subnet mask 255 255 255 0 SN RAM 68XX amp SN RAM 67xx the carrier should provide Default gateway 192 168 0 1 you with a SIM card to insert into the router along with the Preferred DNS 192 168 0 1 APN username amp password for data connectivity FEB Access Graphical User Interface FEB Insert the SIM card GSM HSPA and LTE models only Open a web browser amp enter the following in the e Locate the SIM slot on the right side of the modem address bar http 192 168 0 1 10000 e Insert the card with its cut side facing forward and on the LOGIN INSTRUCTIONS left e For User Name enter e Using the tip of a pen push it in until it clicks admin lowercase letters e For Password enter last six digits of the unit serial number lowercase Upon successfully logging in you will see the following screen EJ An antenna with an SMA connector should be connected to the router This antenna should meet the specifications listed below Also see Hardware Guide for more informatio
7. n on antennas Figure B GUI e 3G Dual band 800 amp 1900 MHz z e LTE 7OOMHz e Nominal 50 ohm impedance a e Voltage Standing Wave Ratio VSWR less than 2 5 1 Device Senai Numbe 6821 2589530112 installed Firmware Version SN version 4 17 Current System Uptime MM There are 4 methods to provide power to the router j Physical Interface Stat e 4 pin Molex connector available on SN 6X00 ysical Interface Status interface Name Connection State IP Address Link Status e 4 pin screw terminal available on SN 6XX1 EB E e Side mounted 2 5mm barrel connector all models e Power over Ethernet available on SN 6X01EB Cellular Interface Status The modem requires a power source between 8 and 30 VDC to operate Label Color Description GND Black Ground qaam You are now connected to the Management GUI If you should PWR Red Power 8 to 30 VDC 500mA 12VDC see anything other than the GUI screen shown please refer IN White Future feature not supported to the Software User Guide located at www sixnet com OUT Green Future feature not supported Red Lion Controls 20 Willow Springs Circle York PA 17406 www redlion net red lon VERIFY CELLULAR CONNECTIVITY Confirm the following on the GUI see Figure B after logged into the unit Activation Succeeded or Unavailable Connection Enabled IP Address Populated with a network IP address Signal Strength h