Home
User Manual - JR International
Contents
1. c Press FUNC button to enter Function Mode within 20 seconds while LCD shows DISARM d LCD will display FUNCTIONS then Press Aor F button to search one of your demand mode When LCD display the correct mode you want then press ENTER button Note During re programming process any steps have to be completed within 20 seconds or the status will go back to previous mode You may press CE button if you would like to return to the previous mode during re programming operation How to Re program 6 2 1 ARM 1 Mode gt this mode allows you to program zone 1 8 be activated or bypassed a Press Aor button to search ARM 1 Mode gt and then press ENTER b Press ENTER button and then LCD will display ARM 1 gt 12345678 Preset configuration this means wireless zone 1 2 3 4 5 6 7 8 are in ARM 1 Mode as the activate zone c You may press any figure buttons 1 8 to re set activate bypass zone d Please do remember to Press ENTER button to confirm the setting 6 2 2 ARM 2 Mode gt this mode allows you to program zone 1 8 be activated or bypassed a Press Aor button to search ARM 2 Mode gt and then press ENTER b Press ENTER button and the LCD will display ARM2 gt preset configuration this means wireless zone 1 2 3 4 5 6 7 8 are in ARM 2 Mode as the bypass zone c You may press any figure buttons 1 8 to re set activate bypass zone d Please do remember to Press ENTER button to confirm the setting 6 2 3 Set Code gt This mode pr
2. e Key in correct access code 111 or the new access code you changed e LCD will display DISARM you will hear 2 bi bi sounds e You may press the A V button to read the configuration shows on LCD Display and check the current status of sensors detectors Note in this mode configuration can be read only not re programmed For Example ARM1 12 4 78 zone 1 2 4 7 8 of ARMI are activated the rest is bypassed ARM2 35678 gt zone 3 5 6 7 8 of ARM2 are activated the rest is bypassed NG a ae door window of zone 5 isn t close well LB ee Detector of zone 3 in low battery condition In Delay 30 In Delay Time 30 seconds Out Delay 30 gt Out Delay Time 30 seconds Alarm Time 60 gt Alarm Time 60 seconds WL Zone 3 gt Wireless Zone 3 was triggered and this previous trigger was memorized it will be erased automatically in next ARM status HW Zone _ Hardwire Zone 3 was triggered and this previous trigger was memorized it will be erased automatically in next ARM status Bell gt Enable Doorbell function is enabled Bell gt Disable doorbell function is disabled SYSTEM EXTENSION 8 1 This Wireless Security System can co operate with full alarm accessory line from COP Security such as PIR 15980I wireless PIR detector 15 980MT wireless door window move detector 15 980ST Remote Control 15 980ST wireless shake sensor and glass breaking detector etc for more information please contact ou
3. correctly b No transmission Place the Remote Keypad in Control Unit and re process Learning Code 9 3 15 980C2 a LED no indication Check the AC Power Cable and be sure it is well connected b Rechargeable function failed Check the Battery Switch be sure it is at the ON position 7
4. is available to set transmission code up to 6561 code combination Please make sure all code combinations set for every detector and controller are the same Note Because that all the transmission code must be the same So once you have changed detector s transmission code you have to do Learning Code see paragraph 6 1 2 to change 15 980C2 s transmission code also the 15 980K please refer to paragraph 6 2 3 point A 6 1 2 Change transmission code for Central Control Unit 15 980C2 a Press 15 980K Keypad button 1114 be sure the Keypad is attached on the control unit b Control Unit LCD Display shows DISARM and you will hear 2 bi sounds c Press the Learning Code Button on the side of Control Unit Fig 3 1 2 within 20 seconds while LCD shows DISARM LCD displays Learning you will hear 2 bi bi sounds Press any button of Remote Controller 15 980T within 5 seconds after the bi sound You will hear 4 bi sounds again LCD will display Successful after learning code process is completed If the learning code process was wrong the LCD will display Fail then you have to re program again follow the above steps a g ua man 6 1 3 Please refer Fig 3 6 for setting Detecting Zone 6 2 15 980C2 Function re program Any functions re programming have to be processed in Function Mode How to enter Function Mode a Key in the access code 111 original configuration b The LCD will display DISARM if the access code is correct
5. seconds a Press Aor V button to search Alarm Time gt and then press ENTER b Press the figure button for alarm time setting for example 60 c LCD displays Alarm gt 60 Press ENTER button This means the Alarm time was set as 60 seconds 6 2 6 In Delay Time gt This is for setting In delay alarm time time programmable form 0 225 seconds a Press Aor button to search In Delay Time gt then press ENTER b Press the number button for setting In Delay Time for example 30 c LCD displays In Delay gt 30 press ENTER button This means the In Delay Time was set as 30 seconds 6 2 7 Out Delay Time gt This is for setting out delay alarm time time programmable form 0 225 seconds a Press Aor button to search Out Delay Time gt then press ENTER b Press the number button for setting Out Delay Time e g 30 c LCD displays Out Delay gt 30 press ENTER button This means the Out Delay Time was set as 30 seconds 6 2 8 RESET gt this reset function is for reverting to the original preset configuration Press Aor F button to search RESETS then press ENTER LCD display CODES press ENTER button Key in access code and then press ENTER button You will hear 2 bi bi sounds all configuration except the access code will then be revert to the original setting ao oO 6 2 9 Network Zone gt This is used only with optional software pack Press CE button to exit 7 Checking the configuration At Standby Mode LCD displays COP Security
6. siren will sound and the LCD Display will show HGSW g Door open Signal Test e When you open the door or window which had been installed detector 15 980MT under DISARM condition the Door Window Detector will transmit door open signal to Control Unit You will hear Din Don Door bell function please refer to paragraph 6 2 4 e Every time the Control Unit enters ARM condition you will hear 4 bi sounds LCD displays NG before countdown In delay Time that remind you the door or window has not closed well h Low Battery This system provides low battery warning function If any of detectors are in low battery status when Control Unit enters ARM condition you will hear the 4 bi sounds LCD displays LB before countdown In delay Time 1 After you have completed the above tests the Wireless Security System has been successfully installed RE PROGRAMMING You may also re program the preset configuration to meet your requirement 6 1 Change transmission code and zone code Please follow the below procedure for resetting the codes 6 1 1 Change transmission Code of Remote controller 15 980T Detector 15 9801 and 15 980MT a Open the battery cover of controller and detector You will find a 10 bit DIP switch of detector and 8 bit DIP switch of controller bit bit8 is the 3 levels switch for setting transmission code bit9 bit10 is the 3 levels switch for setting Zone Code Fig 3 2 2 Fig 3 3 1 amp Fig 3 4 3 b Switch bit bit8 any combination
7. temperature object b Place the battery in the Remove Keypad 15 980K and then put it in to the hole at right side of Central Control Panel c Fix the hanger on the wall after that hang up the Central Control Unit 15 980C2 in the hanger Recommend to place this Control Unit at the central of security control kits d Plug AC adaptor cable to 15 980C2 you will hear 2 bi sounds LCD will displays COP Security it means 15 980C2 is in Standby Mode remember to slide the battery switch to the ON position Fig 3 1 2 e Place battery correctly in the battery compartment of Remote Control 15 980T and turn power switcher on Fig 3 4 2 5 4 TEST Note Because of the Pulse Count Feature of PIR detector please refer to paragraph 2 3 point a to avoid miss trigging you have to away from the detecting area over 20 seconds before test Please follows the below test procedure for Function Test a Out Delay Time Test e Press the ARM button of Remote Control 15 980T or ARM1 button of Remote Keypad 15 980K e The Central Control Unit will start Out Delay Time countdown for 30 seconds preprogrammed you will hear the continuous bi sounds during Out delay time e You will hear a beep sound after Out delay time and then the LCD will displays ARM 1 Mode gt The Security Control System will be in ARM condition b In Delay Time Test e Trigger the detector For example open the door or window the red LED of detector will light for 1 second and you will he
8. Wireless Home Security System DIY Kits 15 980PKC2 User Manual 1 KITS CONTENTS a 15 980C2 9 Wireless Zones Central Control Unit b 15 980K Remote Keypad c 15 980 Wireless PIR Detector d 15 980MT Wireless Door Window move Detector e 15 980T Remote Controller 2 FEATURES 2 1 15 980C2 Central Control Unit a 9 wireless Zones Zone 1 8 is programmable for arm disarm Zone 9 is programmed for 24 hours arming b 2 hard wired Alarm trigger input 24 hours 1 DC 12V Alarm output c User can define 2 ARM Modes ARM 1 amp ARM2 each mode has 8 wireless detection zones which can be programmed as activate or bypass randomly Each wireless zone can co operate with unlimited number of COP wireless alarm accessories sensor detector etc d Built in rechargeable battery which allows Central Control Unit to work continuously up to 4 hours when AC power off e Built in 110dB Siren f 16 Character Back light LCD display 2 2 15 980K Remote Keypad a b C d 6 This Remote Keypad is able to set access code and operate all other functions when it is attached to the Central Control Unit This keypad can be apart from the Central Control unit as the remote controller only controls ARM1 ARM2 DISARM and PANIC 20 push buttons 19 programming button and 1 Panic button can control arm ARM1 amp ARM2 disarm Panic Low battery LED indication green light Power LED indication red light 2 3 15 9801 Wireless PIR Detec
9. ar 3 bi sounds the detector will transmit signal to Central Control Unit e Central Control Unit will start In delay Time countdown for 30 seconds preprogrammed e After In delay Time countdown is completed you will hear the alarm sound from the Siren of Control Unit for 60 seconds preprogrammed Alarm time e When the Alarm sound stop the system will be back to ARM condition LCD will displays for example WL Zone 1 if triggered signal was from Wireless Zone 1 c 15 980T 15 980K Disarm Function Test The user may press the DISARM button of 15 980T or buttons 111 of 15 980K 111 1s the preset access code for disarming Note the Remote Keypad 15 980K will be disable for 60 seconds if the user key in wrong access code for 3 times d Panic Alarm Test Before you remove the Remote Keypad as the remote controller you have to key in the access code 111 and apart the keypad within 5 seconds from the time of enter access code Otherwise the Alarm will be triggered LCD shows Panic alarm e 15 9801 15 980MT Vibration Detection Test The detector 15 980I amp 15 980MT has built in vibration detection for self protect So when Vibration Jumper is in ON position see Fig 3 2 2 Fig 3 3 1 the detector will trigger the alarm function once the detector is vibrated or destroyed f 15 980C2 Vibration Detection Test Because the Central Control Unit has built in vibration detection so once the Control Unit was vibrated or destroyed the Control Unit
10. f ma 8 bit 34evel DIP switch 12VDC battery Fig 3 4 1 Fig 3 4 2 Fig 3 4 3 PANIC BARAS vu k gt An 5 granas gu uv YET Ge eo oo m Goasa ToS AR gt ee a j Rear LB LEDilow battery Power LED Fig 3 5 1 Fig 3 5 2 Bit9 Bit 10 HoouououuD ij L a Transmission Code ZoneCode J I MEI iii Fig 3 6 m 4 Baj 5 a 7 Please refer to Fig 3 6 for setting Detecting Zone 4 5 Preset configuration 4 1 15 980C2 a Access code 111 b In delay Time 30 seconds c Out delay Time 30 seconds d Alarm Time 60 seconds e ARMI zone zone 8 activate f ARM2 zone zone 8 bypass g 15 980 4 2 Preset Zone for detector a 15 980MT zone b 15 980I zone 2 INSTALLATION amp TEST 5 1 This Central Control Kits was programmed for ready to use The user may reset the access code if he prefer other access code to instead 5 2 CHECKING Check the DIP switch of all detectors and remote controllers please be sure all the preset configuration are the same Fig 3 2 2 Fig 3 3 1 Fig 3 4 3 5 3 INSTALLATION a Install all detectors on the proper place For example place 15 980MT on the door or window Fig 3 3 2 15 9801 on the wall Fig 3 2 1 After complete installation check battery is in the detector correctly turn the power on Note 15 980I PIR Detector is for indoor use To avoid miss triggering please do not place the detector facing abnormal
11. ovides 2 functions A 15 980K Learning Code a Press Aor V button to search Set Code gt and then press ENTER b Press ENTER button and then LCD displays Code gt the green LED of KeyPad will quick flash for 0 5 second and you will hear 2 bi sounds This means the learning code process is successfully completed c Press CE button to return to previous Mode B 15 980K Changes Access Code a Follow the above process to enter into Code gt b Key in the original programmed access code 111 your will hear 2 bi sounds and then press ENTER c LCD displays Newly gt key in the new access code available for 3 5 digital number then press ENTER button d LCD displays Again gt then key in the new access code again for confirmation e Press ENTER button you will hear 2 bi bi sounds and the changing access code 1s successfully completed 6 2 4 Door Bell gt Only the wireless zone can be set as doorbell in DISARM condition In this mode you may enable or disable the doorbell function Once wireless Zone 1 is triggered Control Unit will sound Din Don a Press Aor button to search Door Dell gt and then press ENTER b Press Aor V button to select Bell gt Enable or Bell gt Disable c If Press ENTER button after LCD displays Bell gt Enable then the doorbell mode is functioned d If Press ENTER button after LCD displays Bell gt Disable then the doorbell function is disabled 6 2 5 Alarm Time gt Alarm time programmable from 0 255
12. r local dealer or visit our web site www cop security com 8 2 Wireless Zone 9 is 24 hours arming which is able to co operate with 15 980MT door window detector gas detector smoke detector etc 8 3 Co operate with 15 980SL Wireless Siren for additional protection Once the Central Control Unit alarm is activated the Siren is triggered at the same time and will flash amp sound continuously until the alarm is stop 8 4 Co operate with 15 9802D Wireless Voice Auto Dialer Once the Alarm is triggered this Dialer will automatically dial the pre set telephone number twice and send the pre set voice message twice 8 5 Co operate with 15 980R Wireless Multi Channel Repeater that can extent detective distance for another 30M 8 6 Co operate with hardwire detector sensor or external Siren please refer to Figure 3 1 3 for installation Trouble Shooting 9 1 15 980I 15 980MT a LED no indication check the battery and power switch Be sure battery is placed well and power switch is at ON position b Wireless Zone has no transmission e Check the Control Unit and all detectors and be sure their transmission code is the same e Check the Control Unit and be sure this wireless zone has been programmed in ARM status e Check and see if the detector was barricaded or exceed the wireless transmission distance In this situation you may try to re place it to a proper location 9 2 15 980K a LED no indication Check the battery be sure it 1s placed
13. tor a Provides Pulse Count Feature to avoid miss triggering Once the Detector was triggered the red LED of detector will flash but PIR Detector will not transmit signal to the Control Unit unless the next trigger was detected within 20 seconds from previous trigger b Detecting Distance 8M Detecting Angle 110 c Built in Vibration Detection for self protect Jumper ON see Fig 3 2 2 d Low Battery Indication 2 4 15 980MT Wireless Door Window move Detector a This detector will transmit different signal for door window close or door window open to Control Unit b This detector can be co operated with other sensors For example gas detector smoke detector etc c Built in Vibration Detection for self protect Jumper ON see Fig 3 3 1 d Low Battery Indication LB LED green light e Power on Indication ON LED red light 2 5 15 980T Remote Controller a 3 key buttons for Arm Disarm Panic wireless remote control key button ON ARM 1 H DISARM T PANIC b Code learning function c ON LED red LED will light while pressing any key of 15 980T 3 Structure Figures 3 1 15 980C 2 Front Side Aa MILES SRMTLED MEMO LED a anil Fig 3 1 2 LEMEE SANTUN LI BAN WG COM BTC DE ITA PER Jhe Fig 3 1 3 a an lm PAHIT BST TOR d IH Frerv REH F are 2 auni Fig 3 2 2 Fig 3 2 1 Ties Sie See Le Cs Lisi lb EEA Dee CaF il CAF vet E Power on of