Home

USER MANUAL - Mega Systems

image

Contents

1. D e LED STROBE RGB USER MANUAL Table of Contents Safety Information VR E RARO RT A 3 SPECIICAO Skoda n ti 4 Main Power Connection 5 DMX 512 Connection ee ceee cece eee eeeeeeeeeeeeeeneeeeneenees 5 Main Control Men e eiai 6 DMX OM aes sed cea te descended a E AE ORR 8 Rigging the FixtUre 10 Cleaning amp Maintenance i 10 Parts List Check that the unit has not been damaged during transport Read all cautions and warnings prior to operation of this equipment Protection Against Fire Fire Maintain a minimum of 1 foot distance from any type of flame Replace fuse only with the specified type and rating Do Not install the unit to close to a heat source Make sure cable are properly secured Maximum surface operating temperature 80 PR Protection Against Fire A Electrical Disconnect power before servicing For connection to main power supply proceed to page 5 This unit must be earthed electronically grounded Do not expose unit to rain or moisture PS Protection Against Mechanical Hazards 1 Use safety chain when hanging unit ak 2 Use quality clamps or bolts when positioning unit 3 Do not open unit while it is on risk of electrical shock Mechanical Technical Information Part Numbers 3011 XS Led Strobe RGB Mechanical Specifications DMX Connectors 5 pin XLR con
2. Slave units Slave On Slave Mode the fixture will copy the functions on the Master unit To Set the Desired operational mode press Enter Use the Down or Up to select the desired mode and press Enter to confirm your setting To set the desired operational channel mode press Enter Use the Down or Up to select the desired DMX profile operational mode from A B C and D and press Enter to confirm your setting Note Operational mode are located on Page of the manual This function will give you access to the Preprogramed Chases Press Enter Use the Down or Up to select the programed chase press Enter to confirm your setting Use the Down or Up to select the desired speed of the Chase from 1 to 15 press Enter to confirm your setting This function will give you access to set strobe rate via display Press Enter Use the Down or Up to select the desired color Press Enter use the Down or Up to select intensity from 0 to 255 You can repeat this process to get any color combination Note once strobe is set you can power up and the last strobe setting will auto matically come on Strobe intensity This function will give you access to set Intensity via display Press Enter Use the Down or Up to select the desired intensity Press Enter use the Down or Up to select intensity from 0 to 255 You can repeat this process to get any color combination Note once intensity is set you can power up and the last Intensity setting will automatic
3. be accompanied by a copy of the original invoice Goods repaired under warranty will be returned to the owner with the freight prepaid by MSI via the most economical means of shipment Repair or replacement as provided for under this warranty is the exclusive remedy of the consumer MEGA SYSTEMS INC makes no warranties express or implied with respect to any product and Mega Systems specifically disclaims any warranty of merchantability or fitness for a particular purpose Mega Systems shall not be liable for any indirect inci dental or consequential damage including lost profit sustained or incurred in connection with any product or caused by product defect or the partial or total failure of any product regardless of the form of action weather in contract tort including negligence strict liability or otherwise and weather or not such damage was foreseen or unforeseen Warranty is void if the product is misused damaged modified in any way or for unauthorized repairs or parts This warranty gives you specific legal rights and you may also have other rights which vary from state to state Mega Lite 5 18 Kenwick St san Antonio TX 78238 Ph 210 684 2600 Fax 210 855 6279 www mega lite com info mega lite com
4. ally come on Tools Display This function will give you access to the Display Control press Enter Use the Mode Down or Up to select the desired display operational Mode from Display On that will leave the display always turned on Or Display Auto that will make the display turn off after no usage for 60 seconds press Enter to confirm your set ting This function will give you information of how long the fixture has been turned on This function gives you information of the fixtures current temperature This function will give you access to lock the menu keys so they are not accident ly moved Press Enter Use the Down or Up to select the desired Key settings from Lock Or Unlock press Enter to confirm your setting You will have to hold the Enter button for 3 seconds to unlock the keys Value If DMX signal is lost The Fixture will hold the last DMX value Hold sent value If DMX signal is lost The fixture will bring dimmer channels to Clear zero Status oO gt lt DMX Profile XS LED RGB 3 Ch A Mode _ da Red intensi 0 255 0 255 Blue intensity 0 255 XS LED RGB 7 Ch B Mode pa i Dimmer 0 255 2 itenety Reames 0266 Strobe No Function 0 5 NoFunction _ XS LED RGB 8 Ch C Mode 2 3 4 0 0 Ramp Up Effect slow to fast Ramp Down Effect slow to fast 43 85 NoFurneetion OA O 3 Segment Macro Macro 10 slow to fast XS LED RGB 9 Ch D Mode 5 5 1 Red Dimme
5. ere must not be any deformations on the housing fixation and installation spots ceiling suspension trussing 3 The electronic power supply cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed Note There is no serviceable parts inside the device except for the LED s Maintenance and service operations are to be carried out by authorized dealers Replacing the fuse Only replace the fuse with the same type and rating Replacing the power cable If the power cable of this device becomes damaged it has to be replaced by author ized dealers or trained professional only Should you have further questions please contact your dealer Parts List 3010 FAN Replacement fan 3010 PCBM Main PCB card 3010 PS Power Supply 10 Warranty Information Warranty Conditions Unless otherwise stated in writing your product is covered by a one year parts and labor limited warranty LEDs are not guaranteed to match in color temperature or output It is the owner s responsibility to furnish receipts or invoices for verification of purchase date and reseller or distributor If purchase date cannot be provided date of manufacture will be used to determine warranty period Goods returned under warranty must follow the proper authorization procedure and must
6. lows This fixture is equipped with an electronic power supply that will let the unit operate from 90V to 240V from 50Hz to 110V 220V Connec Connec DMX 512 Connec The fixture is equipped with 5 pin XLR Sockets for DMX input and output The sockets are wired in parallel Only use a shielded twisted pair cable designed for RS 485 and 5 pin XLR plugs and connectors in order to connect the controller with the fixture or the fixture with another DMX input DMX output Caution At the last fixture the DMX signal needs to be terminated with a terminator Solder a 120 Ohm resistor between the and the signal into a 3 pin XLR plug and plug it in to the last fixture on the signal run Pre manufactured terminator plugs are availa ble for purchase from your Mega Lite dealer P DMXT Display Menu CONTROL BOARD The control board on the fixture base is your interface to access and control all the functions on the unit Its digital display gives you a code Mega Lite view of the options and functions The following will explain each func tion and its options o o ESC DOWN UP ENTER To Set the DMX Start Channel press Enter Use the Down or Up to select the desired DMX Start Channel and press Enter to confirm your setting U DMX 512 This mode will allow you to operate the fixture with a DMX con ork Mod Master This Function Allows you to run the Auto Programs Or Audio Pro grams and send DMX signal out to the
7. nectors in and out 4 Thermal Maximum ambient temperature 104 oo Maximum surface temperature 140 Fastening System Single Mounting Yoke Display Digital CELLES eocosoonoono oe0co0nooo nosso onnogo nt0000000o Lefefefefefefefa te Lefefefefefefafe e ooooooann ooooooann ooooooann uoogooann GEELES I p uecscsconono oesocnnsoono LLELLE nocscsoonno 4 8 Power connection Power Con in amp out 1 12 Eep Size 13 66 x 4 x 7 12 Size 30 5 x 23 x 20 66 Weight 6 5 Ib Weight 60 5 Ib empty Electrical Specifications LED Quantity 324 RGB SMD LEDS LED Angle 140 Power Input Voltage 110V 240 50 60 Hz Fuse 5x20 F5AL250V Ballast Electronic auto switching Power Consumption Watts 165 Amps 2 49 LED Watts 50 LED Lifetime 60 to 100 thousand hours Control amp Programming DMX 512 Protocol DMX Modes Mode 1 3 Channels R G B Mode 2 7 Channels Dimmer R G B Strobe Macro Mode 3 8 Channels Dimmer R G B Strobe Macro 3 Segment Macro Mode 4 9 Channels R G B X3 Control Options Display Control Master Slave Main Power Connec Caution if Do not connect fixture to a dimmer system 2 This unit has Auto switching power supply It will respond to 110V or 220V automatically di This unit must be earthed electronically grounded 4 Replace fuse only with the specified type and rating The occupation of the connection cable is as fol
8. r Segment 3 0 255 Green Dimmer Segment 3 0 255 Blue Dimmer Segment 3 0 255 Rigging the fixture Caution 1 The installations must be carried out by an authorized dealer or trained professional 2 Unit may cause severe injures if you have doubts concerning the safety do not install 3 Unit is to be 24inches away from flammable materials decoration material 4 Use high quality installation equipment to hang unit When rigging a unit it is very important that you follow common safety procedures Rigging requires extensive experi ence including but not limited to calculating working loads material being used and periodic safety inspections If you lack these qualifications do not attempt the installation yourself instead use a professional structural rigger When rigging the unit always be secured with a secondary safety attachment The installation location of the fixture has got to be built in the way that it can hold 10 times the weight for 1 hour with out any harming Installation should be checked at least one time a year by a skilled person Cleaning and maintenance Installation Maintenance The operator has to make sure that the unit is operating safely and has the installa tions and electronics checked by an expert every 2 years The following points have to be considered during the inspection 1 All screws used for installing the device or part of the device have to be tightly connected and must not be corroded 2 Th