1. MP 204D Digital Analog Stereo Monitor Panel Videoquip Research Limited 595 Middlefield Road Unit 4 Scarborough Ontario Canada MIV 3S2 416 293 1042 1 888 293 1071 www videoquip com Videoquip MP 204D User Manual The MP 204D is a digital analog monitoring panel allowing either analog or using an optional plug in board digital audio AES EBU stereo signals to be monitored via internal speakers or headphones Front panel metering is provided with a bar graph type LED display for both analog and digital signals As described above the digital audio board is available as an optional plug in device If it is installed the MP 204D will sense the board and the front panel input selection switch labelled DIGITAL will allow the board to be used If the board is not installed the MP 204D will function as a stereo analog monitor and the DIGITAL switch will be inactive When the red LED indicator associated with the DIGITAL switch is illuminated as the switch is being pressed the MP 204D has found the digital audio board This will allow either digital audio input labelled A or B to be monitored Two stereo analog signals or two stereo digital audio signals may be connected via the rear panel and front panel switching allows either set of inputs to be selected In addition a line output is available on the rear panel via balanced XLR connectors for left and right This allows the selected input signal to be connected to a line
2. lt 0OBH gt lt 5FH gt with checksum enabled To select Analog Input A send the following lt OxAAH gt lt 02H gt lt 00H gt no checksum sent as don t care lt OxAAH gt lt 02H gt lt 58H gt with checksum enabled Note that for test purposes the Windows 95 98 Calculator Accessory will support hexadecimal and logical operations and arithmetic functions and can be used to quickly determine a two s complement value checksum An application program written to control the MP 204D would perform this checksum calculation as part of the transmission to the unit in real time The MP 204D will echo the command string sent to it for the message types defined above Reception of any other undefined message types will cause the MP 204D to ignore the transmission and return nothing to the host Note that on board EEPROM is used to store checksum required not required status as well as to save mode analog level settings and restore power up saved settings MP 204D Specifications Power Requirements Analog Audio Inputs Input Impedance Input Signal Level Maximum Input Level Input Connectors Common Mode Rejection Analog Audio Outputs Output Impedance Output Signal Level Output Connectors Digital Audio Inputs AES3 Input Impedance Input Connectors AES3 ID Input Impedance Input Connectors Amplifier Power Output Frequency Response THD Noise Hum and Noise Speakers Standard Magnetically Shielded Remot
3. LED indicator associated with either A B or DIGITAL switches will flash as a reminder of that state If Analog A was selected for example the LED indicator for Analog A will flash for the duration of the mute The mute condition is sustained for the duration that the mute input pin 9 is grounded and is released when the mute input is removed from ground 10 Warranty Videoquip Research Limited VRL warrants the MP 204D for a period of 2 two years from the date of shipment from the factory to be free of defects in workmanship and material under normal use and service This warranty is void if failure is due to abnormal use or modification or if serial numbers have been tampered with VRL s liability is limited to the repair or replacement of this unit or to a sales credit and the warranty action taken is at the sole discretion of VRL Any warranty claims must be received in writing by VRL before the expiration of the two year period Warranty coverage does not include shipping costs This warranty is in lieu of all other warranties expressed or implied and all other obligations or liabilities of Videoquip Research Limited 11
4. Videoquip Research VP 2D Since internal electronic switching is performed the firmware of the MP 204D will not allow the operating level of a digital input signal to be varied in the same way that an analog signal level may be varied This ensures that the 0 dB LED will always represent a 0 dBFS full scale static signal The meter is based on analog signal processing circuitry and approximates a PPM ballistic response Under dynamic conditions with musical content it is possible for occasional illumination of the 1 dB LED to be observed This usually indicates that a high crest factor for that musical phrase will cause the meter circuitry to slightly over range although the MP 204D cannot accurately process a true digital over condition For a full digital meter incorporating digital signal processing circuitry DSP the over condition would usually be considered a given number of consecutive full scale samples This could possibly indicate that the signal was slightly clipped in a manner similar to analog clipping In digital audio however once saturation has been reached no more codes exist to fully represent that input sample amplitude for a given digital word length A consecutive number of such samples are generally considered an over condition which the DSP can easily accumulate and report to the user via a dedicated over indicator In addition the front panel meter gain only may be trimmed with recesse
5. alive status Checksum Byte If message type 01H has been sent to the MP 204D in a previous transmission it is necessary for a correct checksum byte to be sent as the last byte in all other transmissions until it is disabled by sending message type 00H The MP 204D has an internal EEPROM device to store switching settings as well as the checksum required status This makes it possible to retain the need for checksum processing even after a new power up cycle The status is updated in EEPROM after receipt of message types either OOH or 01H The checksum is calculated as the two s complement XOR sum of the first 2 bytes of the transmission not including byte 3 the actual checksum byte Example1 If checksum processing has been enabled using message type 01H then the following would describe the switch update messages from 0x02H to 0x09H Byte 1 Byte 2 Byte 3 lt OxAAH gt lt 0x02H gt to lt 0x09 gt lt valid checksum gt This will update the switches as defined previously The checksum can be sent as any value from 00H to OFFH if checksum processing has been disabled Example2 To disable checksum processing send the following command lt 0xAAH gt lt 00H gt lt 00H gt no checksum To enable checksum processing send the following command lt OxAAH gt lt 01H gt lt 00H gt no checksum The Alive Inquiry is selected as follows lt 0xAAH gt lt 0BH gt lt 00H gt no checksum sent as don t care lt 0xAAH gt
6. level input device such as a power amplifier if desired The MP 204D supports four output mode selections as monitoring choices They are STEREO LEFT ONLY RIGHT ONLY and MONO Four mode switches located on the front panel with associated LED indicators allow each mode to be selected easily for monitoring convenience Further each pair of inputs either analog or digital may have a unique output mode The firmware of the MP 204D retains the mode associated with that input unless it has been modified For example Analog Input A may be set to monitor in STEREO and Analog Input B may be set to monitor in MONO Switching between A and B will retain that selection until it has been changed The digital audio inputs function accordingly as well Upon power down of the unit the last monitored input with its associated output mode selection and level if it is an analog input will be restored upon power up A stereo headphone jack is available on the front panel allowing the signal to be monitored via a suitable pair of headphones In normal operation the front panel speakers are disabled when headphones are inserted It is also possible to install a set of internal jumpers J9 J11 on the main circuit board just above the external speaker connector which prevents the internal speakers from being disabled when headphones are inserted A front panel volume control is also available which affects only the headphone speaker volume The front pane
7. alibrated This is a direct result of the fact that operating levels are interpreted differently in analog and digital audio Consequently they require a somewhat different metering methodology The 0 dB LED represents the nominal operating level when monitoring an analog signal where the choices available are 10 dBu 0 dBu 4 dBu and 8 dBu As described the two analog inputs may be set to one of these four standard operating levels independently The digital inputs are calibrated by connecting a 1 KHz 0 dBFS sinewave from an AES EBU digital audio test generator to either Digital Input A or B and selecting the chosen input from the front panel The DIGITAL indicator LED should be illuminated and the appropriate A or B indicator LED should therefore be illuminated according the source of the digital audio input signal On the main board are two rotary potentiometers R97 and R98 labelled Digital Left and Digital Right Adjust The analog line outputs of the MP 204D should be connected to the analog line inputs of a test device capable of reading and displaying the level in dBu of an analog sine wave signal Adjust the potentiometers with a screwdriver until the 0 dB LED is illuminated and the analog output level is 0 dBu The output mode select switches are used to indicate the operating level and incorporate dual color indicators red and green The red LED indicates the current output mode and the green LED indicates the current operat
8. d potentiometers just to the left of each LED array for left and right channel To calibrate the meter for 0 dB with a known analog input source 1 Connect a balanced analog audio sinewave source set to 1 KHz 0 dBu to the left and right inputs of either Input A or Input B 2 Select the Analog A Input Source via the front panel pushbuttons 3 Ensure that the operating level is set to 0 dBu for that input This procedure is discussed on the previous page 4 of this manual 4 Using a small flat blade screwdriver adjust the recessed front panel potentiometers for left and right channel until the 0 dB LED indicator is illuminated MP 204D Control Scheme The parallel remote control and serial remote control protocol for host computer communications with the MP 204D is described The monitor panel can be remotely controlled with either of the following 1 Local Parallel Control which parallels the front panel switch array and provides the same features as the front panel including input selection and output mode selection Note that operating level selections are not available by remote control for either parallel or serial control This was done as a safety precaution The pin configuration is shown on page 10 Additionally a mute input is available as a momentary closure which mutes the active input and flashes the led of the corresponding input switch LED when it is activated This is available only on the rear panel DB 9F parall
9. e Control Parallel Remote Serial Remote 115 VAC 60 Hz or 230 VAC 50Hz 12W 40 Kohms balanced 20 Kohms unbalanced 10 0 4 or 8 dBu front panel selected 24 dBu front panel CLIP indicator at 21 dBu XLR 3F and TRS x 4 60 dB 60Hz 66 Ohms balanced 0 dBu nominal 24 dBu max XLR 3M x 2 switch selectable rear panel 110 Ohms transformer isolated XLR 3F x 2 switch selectable rear panel 75 Ohms BNC Panel Mount Female x 2 4 Watts RMS per channel into 8 Ohms 20 Hz to 20 KHz 1 dB 0 1 or less full bandwidth 70 dBu 3 x 5 inch oval 4 Watts 8 Ohms 3 x 5 inch oval 4 Watts 8 Ohms DB 9F pull down to ground RS 422 DB 9F 9600 Baud No Parity 8 Data 1 Stop Checksum Enabled or Disabled RS 422 DB 9F Remote Control Connector Pin Configuration Pin Number Function N C TXD RXD GND N C GND TXD RXD N C 00 N O 01 Oo PO Parallel DB 9F Remote Control Connector Pin Configuration Pin Number Function MONO SUM LEFT ONLY DIGITAL A INPUT GND RIGHT ONLY STEREO B INPUT MUTE 00 Ni Od 01 Go PO All parallel remote functions are implemented by a momentary connection of that pin to ground pin 5 which is recognized by the MP 204D immediately The mute input is available only on the rear panel remote connector Note that when the mute input is active the
10. el remote connector 2 The RS 422 serial remote control input at 9600 Baud No Parity 8 Data 1 Stop Bit When RS 422 remote control is desired this is available as a rear panel DB 9F connector MP204 AD Serial Remote Protocol Description The MP 204D does not include any provision for a logical address as would be found in a daisy chained multi drop environment The protocol consists of a header byte a message byte and an optional checksum byte The MP 204D provides host communications at 9600 Baud no parity 8 data bits and 1 stop bit The protocol is a constant length 3 bytes protocol with all bytes required although don t care data the value can be from anything from 00h to OFFh can be sent for each unnecessary checksum data value All message types except type OAH Get Digital Card Status will echo the three bytes as sent to it as confirmation that it is connected to the host and that communications has been established A special message type can be used as an Alive Inquiry lt OBH gt which simply returns or echoes the received bytes with no internal processing to test communications with the MP 204D Protocol Format Header Message Type Checksum lt AAH gt 00H to OBH Optional or 00H to OFFH Defined Message types for the MP 204D are as follows in hexadecimal notation 0x00H Disable checksum processing This message type forces the MP 204D to ignore checksum data as received although a dummy chec
11. ing level selection for the selected input In order to prevent inadvertent changes to the operating level for Analog Input A or Input B the selection of either level is accomplished via a recessed front panel switch labelled SET LEVEL To set the operating level of either Analog Input A or Input B 1 Ensure that the DIGITAL indicator is OFF by selecting the pushbutton alternately until the LED is off Note that if the digital audio board is not installed the analog inputs only will be available by default Y Select the Analog A Input via the pushbutton The indicator will be illuminated oo The selection of a standard monitoring level is accomplished by inserting a small thin screwdriver or similar object in the access hole labelled SET LEVEL Push and hold the internal recessed switch with the screwdriver while at the same time pressing the desired level pushbutton The green indicator shows which level is being selected and the selected level will be saved automatically 4 Repeat as needed for the Analog B input Ensure that the Analog B indicator is illuminated for that input before changing the level This procedure applies only to the analog inputs Additionally a CLIP LED will illuminate when the analog signal level exceeds 20 dBu When monitoring a digital audio signal however the 0 dB LED is calibrated to represent a full scale 0 dBFS digital audio input signal similar to most digital audio meters including the
12. ksum must be sent as a don t care value since the protocol is constant length 0x01H Enable checksum processing This message type forces the MP 204D to receive a correct checksum of the received data before updating the switch settings This serves to minimize the effect of communication line errors that would affect the data The received checksum must match the checksum calculated by the MP 204D before the new setting is updated If the received and calculated checksum values do not agree then that transmission is ignored as far as an update is concerned however the command is echoed to the host 0x02H Select analog input A 0x03H Select analog input B 0x04H Select digital input A If the digital card is not installed the switch settings will not update 0x05H Select digital input B If the digital card is not installed the switch settings will not update Ox06H Select stereo output mode 0x07H Select left only output mode 0x08H Select right only output mode 0x09H Select mono sum output mode Ox0AH Get Digital Card Status Determine the status of the digital card i e installed or not installed The firmware will respond with the following data after receipt of this message AA 0A 00 Digital Card is installed AA 0A FF Digital Card is not installed 0x0BH Alive Inquiry This message type will simply return echo the message with no internal action on the part of the MP 204D as confirmation of
13. l meter and line out are independent of the internal monitor power amplifier and will function normally with the volume control set to minimum Each digital audio input A and B supports both AES3 XLR balanced inputs and AES3 ID BNC unbalanced inputs for maximum versatility without requiring external switching Both input types are considered professional with regard to channel status information which is of no concern to the MP 204D since it recovers and monitors only audio signals It is therefore possible to connect an S PDIF consumer source as well with a BNC to Phono RCA adapter since AES3 ID and S PDIF both support a 75 Ohm transmission line impedance A slide switch associated with each digital audio input is provided to select the incoming format To monitor an S PDIF digital audio signal simply connect the correct BNC to RCA adapter and set the slide switch to the AES3 ID position for that input As described two stereo analog inputs are available Inputs A and B The sensitivity of these analog inputs can be adjusted via the front panel and saved in on board EEPROM Analog Input A can be set for example to 0 dBu and Analog Input B could be set to 8 dBu When switching back and forth between inputs the gain will be electronically altered for each one to accommodate the desired sensitivity The digital audio inputs however default to the equivalent of 0 dBu or 0 dBFS to ensure that the front panel metering is always c