Home
        Fresco-S Multi-viewer Quick Setting-up Manual
         Contents
1.         F    DAYANG    Fresco S Multi viewer Ouick Setting up Manual    DayangTechnology Development Inc 2013 04    Dayang Technology Development Inc     Fresco S Multi viewer Quick Setting up Manual    Contents  System Components anne ALA Aasa aan ea AA  1  Hardware Fresco S chassis front panel                     1       2  Hardware Fresco S chassis rear panel             ooooooooooo oo a  3  EQUIPMENTS connection diagram            oooW oom  Description of equipments connection                     ooWo Woo  1  EQUIPMENTS preparation            o Wo  Wo oo oW WWW mma  2o LAU Se Ona eno maan  3  Start    p test and verification we ama AA  A The setings OKey DAKIMELEN aaa NAALAGAAN GAAN  5  Interaction between control terminal and Fresco eguipment                   oWooooo    Dayang Technology Development Inc     Fresco S Multi viewer Quick Setting up Manual    Fresco S Multi viewer Quick Setting up Manual    System components    1  Hardware Fresco S chassis front panel    F    K H AK    WHY  f    i Ui U M UW       2  Hardware Fresco S chassis rear panel    i Tr pring 3Gbps HD SD I  SD SD1 CVBS  ase  oc    cence      Auto sensing HD SDI output              for monitor i ing power  supply       Analog Audio  HDMI Input  RS422 AES EBU  GPI O   Audio Tally  LTC HDMI Output  Monitoring   speaker or  headphone     3  Eguipments connection diagram               3G HD HD SDI CVBS   utomatically adapt input    control terminal       TCP IP    4 HDMI inputs Fresco S       Dayang Techn
2.   parameter  pixel difference level  and  area tolerance level  can be set to 1  For analog signal  set    above two parameters to 5     3  Audio config    Dayang Technology Development Inc     Fresco S Multi viewer Quick Setting up Manual    di Device Config         Common Comm  Video Config ig Audio Config    Audio silence    Tarn threshold     Error threshold     Audio Overload hudio Low    Harn threshold  Pe KI Warn threshold     Error threshold  Error threshold     Default           The probing thresholds of audio overload and audio too low are related to maximum value  and minimum value  the empirical value of former is  6dBFS  and  20dBFS for later  i e  audio    under  20dBFS is considered to be too low  and audio over  6dBFS is too high     5  Interaction between control terminal and Fresco equipment   1  Start MVDesign software  and login specified Fresco S multi viewer by its IP address  import  proper layout templates according to practical use and based on this to complete quick edit  for layout    2  In the template presets list  choose Template9 3840x2160  and click Apply in right click    menu  this layout template is set to editable     Dayang Technology Development Inc     Fresco S Multi viewer Quick Setting up Manual    3     4     5     6     7      Fresco       After finish edit  save this layout  Use   Synchronism  button BI to upload layout of    control terminal to multi viewer and display it in the screens     Can also use  Reverse Synchronism  button
3.  Lal to download layouts saved in    multi viewer to control terminal    For various layouts produced in software  besides users can upload them to multi viewer  chassis to realize switching between different layouts  can also backup these layouts by use  of export function of MVDesign software    Next  combine with one typical layout  briefly instruct some notes  For example  adopt 2x2  jointing type for 4 HDMI outputs  the resolution can achieve 3840x2160 after jointing of    screens  the effect is shown as following     o     Dayang Technology Development Inc     Fresco S Multi viewer Quick Setting up Manual    Analog Clock    Alarm frame  Volume Meter       FHe  sco    16 9 video   Nf i TT    Uu NG     Metadata Info     Signal UMD Video Background       8  This layout is one of layout templates in Fresco S  including video  volume meter  text  UMD   video background  analog digital clock  metadata and some other frequently used elements   The numbers shown on layout indicate the output seguence of displayers    9     Users are able to overlay video windows on background or not  Volume meters can be  located in double sides of video window or single side  Volume meters can also be    positioned inside the video window in transparency or outside  users can adjust layout by    u      Dayang Technology Development Inc     Fresco S Multi viewer Quick Setting up Manual    their needs to achieve best display effect     1      
4. nc     Fresco S Multi viewer Quick Setting up Manual      Modify Password    Old password     Hew password        When complete modification of IP address and login password  can use new IP and    password to login Fresco S multi viewer     3  Start up test and verification   After successful start up  need to test Fresco S inputs and outputs  In test process at least  need one SDI signal source  traditional device   one HDMI signal source  laptop   one displayer  with HDMI input and one monitor    After start up  system will automatically apply following layout  1920x1080 20   20 signal  sources from first VA module will be displayed  Use HDMI cable to connect HDMI O of first  module with displayer  use BNC cable to connect Out  HD SDI monitoring output  of first VA    module with monitor     HUSTO      Fresco Multiviewer Monitoring System         Dayang Technology Development Inc     Fresco S Multi viewer Quick Setting up Manual    Orderly connect all SDI signal sources to four modules with 16 SDI inputs in all  and orderly  connect all HDMI signal sources to four modules with 4 HDMI inputs in all  verify normality of  each signal by use of displayer  In the meantime  users can also check HDMI outputs and HD SDI  outputs    By this way can quickly judge outputs and inputs of multi viewer are whether normal or not     if there are any problems with VA modules  please contact customer service to change     4  The settings of key parameters   Click  Config  button in main inte
5. ology Development Inc    7 Fresco S Multi viewer Quick Setting up Manual    Description of equipments connection  1  Equipments preparation   gt  2 PCs are control terminal and monitor end    gt  Multiple Fresco S multi viewer chassis  cascading according to real needs     gt  Big screens used to display multi viewer output signals      Signal sources and signal cables which take function of connection between signal  sources and multi viewer chassis  according to real needs     gt  Breakout cable  GPI O  Tally  LTC  Analog audio  AES EBU   Instruction  the interfaces of breakout cables of each module can realize 8 expansions of    GPIO by DB15 slot  the definition of DB15 pins is depicted as follow        2  Start up settings  Before starting up chassis  need to ensure normal network connection between control  terminal and multi viewer chassis  and connect HDMI outputs of each modules to video    terminals     Dayang Technology Development Inc     Fresco S Multi viewer Quick Setting up Manual    inin Tr ba 3Gbps HD SD I SD SD1 CVBS  ase Iioc e  Eiane      Auto sensing HD SDI output kenakan    for mon itor ing power   gt  supply       Analog Audio  HDMI Input  RS422 AES EBU  GPI O   Audio Tally  LTC HDMI Output  Monitoring   speaker or  headphone     Next  plug two power supply cables  take down front panel  and turn on left and right  side power switch  In the process of multi viewer starting up  wait round 1 minute  the  starting up interface will be displayed in output te
6. rface to pop up  Device Config   window  can set a variety  of parameters of VA outputs  as shown in the picture    Users can modify relative parameters according to real requirements  for detailed parameter  settings  please refer to  MVDesign software user manual  chapter 3 5 7  here will not give  unnecessary details      1  Common settings      Device Config    Common    Output Video Standard Dynamic UMD Protocol    fo  1080 50F C  1080 59  94P   o  Dayang    Backer ound    Fi    TEL ial     V  Enable Background Output   TAE pan    SDI Output C  TSL over UDP TIF UDF Port       3G SDI Output    Analog Digital Audio  Audio Group 1     J Digital 0  Analog  Audio Group 2    J Digital   Audio Group 3       Digital    Audio Group 4       Digital                According to practical use  refer to input resolution and refresh frequency  users can set          Dayang Technology Development Inc     Fresco S Multi viewer Quick Setting up Manual    video standard to 1080 50P  default  or 1080 59 94P     Lower is the part of audio config  digital audio input is for default  and Audio Group    represents the sequence of modules     2  Video config      Device Config    Video Config Aui    Black burst Frozen video    Fixel difference level  r Fixel difference level     Area tolerance level  7 Area tolerance level     Yarn threshold  r Tarn threshold     Error threshold    Error threshold        With regard to probing  video frozen  and  video black  of video signal  For digital signal 
7. rminals    At lower right corner of starting up interface  the default IP  subnet nnask and gateway  will be shown in yellow fonts  please recode these information    Instruction  when control terminal software connect to multi viewer chassis  users    need to input IP address of multi viewer chassis        Modify IP address of control terminal PC according to connection information of  Fresco S chassis  make IP addresses of control terminal PC is in same network segment with    Fresco S chassis     d    Dayang Technology Development Inc     Fresco S Multi viewer Quick Setting up Manual    After configuration  open MVDesign software  press connect button Mel in software  window to pop up login window  input IP address in starting up interface of Fresco S chassis     such as 100 0 2 129   the default password is admin  then press login button     IP Address    100 0 2 129    bai    Save Information Remember PassWord       After login  click   Device   menu  choose   Network Setup Ito pop up   Network Setup     window  users are able to modify IP  subnet mask and gateway based on real requirements         Network Config    Use the following IF address     IF address  loo  O  Subnet mask  lala ea ea     Default gateway  100  0    bl            Cancel             Users can also modify default password  Click  Device Jmenu  choosel Modify Password      to pop up  Modify Password  window  new password can be set after old password    verification     Dayang Technology Development I
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
USER MANUAL - University of Warwick    DCR-TRV33E  Diapositive 1  Design and Implementation Process for Controls - e  MAGAZINE N° 51/52/1  InFlight Exchange (IFx) Caterers User Manual:  Optimus H7100 Use and Care Manual  Battery-Biz MUSIC Pro Pro IT User's Manual  Windsor VOYXDU 10086150 User's Manual    Copyright © All rights reserved. 