Home
Hydraulic Pumping Unit (HPU)
Contents
1. check traffic lights and replace any burned bulbs or LEDs Check safety devices loop IR etc for proper operation and report any anomalies if applicable Check the PLC for normal operation of all logic and functions Lubricate all pivot points and the clevis pin Inspect the cylinder and report abnormalities if present Check hoses for wear and report any abnormalities D OO O OOO OOOO OCODDUDDUC B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611X Series HPU MAINTENANCE 13 Check the operation of the control panel s Check the control panel s buttons and lights for proper operation and replace if necessary Update the operation and maintenance log 3 3 Six Month Inspections We recommend you perform the following inspections every six months Repeat the visual inspections in the monthly inspection list Turn the master power switch on the control circuit box to the OFF position Inspect the hydraulic system for signs of oil leaks CAUTION The hydraulic system when in operation is under extreme pressure Verify pressure on the barrier is completely relieved prior to removal of any hydraulic fittings Check the hoses for wear or abrasion Check all fittings for tightness Inspect the oil level in the HPU by opening the tank the level should be 1 1 5 inches below the top of the tank Add oil as necessary We re
2. Check pressure gauge Barrier does not open 4 Check overload protector when commanded on 5 Manually open the barrier by depressing the directional control panel control valve to see if problem is mechanical or electrical 6 Check PLC input on pumping unit 7 Check that safeties are clear 8 Check PLC output on pumping unit 9 Check push button operation Check power Check for binding between moving plate and frame Check connection of linkage between frame and plate Check for foreign debris Check pressure gauge Check overload protector Manually close the barrier by depressing the directional control valve to see if problem is mechanical or electrical Check PLC input on pumping unit Check that safeties are clear Check PLC output on pumping unit Check push button operation Check power Check hydraulic fluid level Close pressure relief valve Check power Check motor overload press start Check motor starter Check low level switch par Barrier does not close when commanded on control panel Code 09 COO ON HPU pump will not build up pressure but is running HPU pump will not turn on se ep bcr B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611x Series HPU TROUBLESHOOTING Symptom Actions 5 Check pressure switch Hydraulic unit excessively hot Check that the pres
3. The schematic shown is for a single lane barrier system using a cylinder such as an 820 model B SCHEMATIC CYLINDER CONTROL PRESSURE EFO MANIFOLD FLOW SWITCH PRESSURE coNTROL ia ew La M of gt P B e e _ I E N FZ Jo zi lt FLOW eed 4 sN CONTROL MOTOR A ume N e VALVES im S nd WW ES bo MEE INTERNAL C ACCUMULATOR SYSTEM MANUAL PUMP PRESSURE CYLINDER iid SER Bond hb DIRECTIONAL i 1 VALVE CONTROL VALVE FIELD HOSES Eo t eS RESERVOIR Revision B M D 6 2 Typical Bollard Hydraulic Flow Diagram B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611X Series HPU APPENDIX 18 PRESSURE EFO MANIFOLD SWITCH PRESSURE cylinder 25 DIRECTIONAL CONTROL VAWE 6 3 Electrical Field Wiring Diagram The following figure shows a typical field wiring schematic for a 611X HPU B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 19 APPENDIX Installation and Operations Manual 611X Series HPU tot ames seme eosam co sw rex 193NNOOH3INI v23 0009 ERES M3IMMVB 310IH3A SINIM WVYOVIG 193NNO
4. and Operations Manual 611X Series HPU TABLE OF CONTENTS 6 1 Simplified Standard Hydraulic Diagram eese eene nennen 17 6 2 Typical Bollard Hydraulic Flow Diagram eese esee eere entente tnnt 17 6 3 Electrical Field Wiring Di gram eiecerunt te rite ede Yee Hebe a ee eue dae 18 6 4 Maintenance Log FOYP iiie siete tidie istas trie cea Ee a ER Ee Eee evo Ee ERR CERE RISE 20 1 ORIENTATION 1 1 Overview The model 611X hydraulic pumping unit is designed to operate hydraulic barriers that require medium pressure and high flow The electric motor comes on any time the system pressure drops below the set point and the level of fluid is adequate It is connected directly to a hydraulic pump which operates independently from the signal command The oil from the pump is drawn through a filter and directed into a directional control valve The flow control valve monitors the operational speed of the barrier XENC A24N20ACP ELECTRICAL SIDE PANELS DOORS HOSES AND SOME C NTROLLER FITTINGS REMOVED FOR CLARITY v 6119 2041 BOX A CABINET XHYD FCV N VAL DIRECTIONAL _ CONTROL VALVE SYSTEM RELIEF re pom VALVES _ T XHYD P551553 I T PLI BASE FILTER ASSY 6119 200 i TANK WELOMENTS meti L EFO VALVE amp COIL lt o XHYD CSE CS65 2 19 XIND G610 12AL 771 LM IND G 12 OIL SITE GAUGE 4 y cw
5. ARMR products Spare or replacement parts Custom designs or special installations Equipment upgrades modernize your old equipment with state of the art hydraulics and control systems Ancillary security equipment such as security guard enclosures card readers security lighting and many other security related products Technical support via telephone and possible on site support with advanced scheduling D OOO OO Safety CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611x Series HPU INTRODUCTION lii SYMBOL MEANING The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of non insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instruction in the literature accompanying the product B amp B ARMR does not assume responsibility for injury to persons or property during installation operation or maintenance As the user y
6. Installation and Operations Manual Model 611X HPU Series MODEL 611x SERIES Wedges amp Bollards FRMR Hydraulic Pumping Unit HPU OPERATIONS amp MAINTENANCE MANUAL B amp B ARMR CORPORATE OFFICE amp TECHNICAL SUPPORT 2009 CHENAULT DRIVE SUITE 114 CARROLLTON TX 75006 PHONE 800 367 0387 FAX 972 385 9887 E mail info Gbb armr com techsupport bb armr com MADE IN THE USA B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611x Series HPU INTRODUCTION 11 Your safety is extremely important to us If you have any questions or are in doubt about any aspect of the equipment please contact us INTRODUCTION Welcome Congratulations on your purchase of a B amp B ARMR Hydraulic Pumping Unit HPU In addition to providing detailed operating instructions this manual describes how to install maintain and troubleshoot your HPU If you require additional assistance with any aspect of your installation or operation please contact us We have years of experience in all aspects of perimeter security and related disciplines and our products are used throughout the world to control access and to protect people equipment and facilities We offer a broad range of vehicle barrier and related security services Turnkey installations Routine barrier preventative maintenance or emergency repairs including work on non B amp B
7. O3INI eB GINE dion sexos BRAT ATT S3souz IAH S3UIM 2 OVAIOQA v92 04 v OVAOZ S3MUIM Z GALSIML S39IM Z OVA OQA 92 01 S3HIM 2 OVAOCL p OVAOZL dWNd dNNS 33d SIYM OGArZ 2143 JO S3HIM 6 OQAvZ 2I3JVNL JO S33IM 6 Sd33MS lt 9 ON Sd33MS 1VOI4 10313 TWOIMLOI13 LINGNOD TWNOILdO gt 1 5 WHY 31V9 TYNOIS N3MOd WHY 31V9 1VNSIS ISOH Ola vHOAH HOLIMS ALSIVS QIYYY 4NI M31V3H 313H89NOO Q30038Wl WOLO3130 dOO1 3OMnOS LHOM WY38 AL34VS O3HVHJNI 1H9N Odd VY dWns q13NYd 1ONINOO 915 T3NVd N31S VN S3MOd Qariddns YAWOLSND QN39311 1H9I1OI33VHl LHONM Wv38 AL33VS Q3H VHJNI 31V9 1VNOSIS Y0193130 W3AI3O3H WV38 A3L3VS Q3SVHJNI LINN 9NId Wd On vauAaH dNNS TANVd T1OHLNOO 8hS TANVd TONINOO N31S VW en N M ea 8 2 gt N 1 S E H S 9 d 3 a 2 9 v OL 6 8 9 9 t L A Division of B amp B Roadway and Security Solutions B amp B ARMR Installation and Operations Manual 611X Series HPU APPENDIX 20 6 4 Maintenance Log Form Equipment Maintenance Log oo BS Tel 800 367 0387 703 335 6006 email servicedept bb armr com Location Checklist Perfomed By complete Anomolies Annu
8. afety inputs are ignored during EFO operation 1 1 14 Base Filter Assembly The filter assembly is used to filter contaminants from the hydraulic oil during operation Routine maintenance is required to replace the filter and ensure system is kept free of contamination The strainer and spin on filter should be replaced as part of normal maintenance whenever the oil is serviced B amp B ARMR recommends the use of environment friendly oil such as Mobil EAL 224 in all of our hydraulic systems B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611X Series HPU ORIENTATION 1 1 15 Directional Control Valve The directional control valve operates the unit in the normal operation mode It changes to allow fluid to pass to the barrier for deployment 1 1 16 Cabinet The pump cabinet houses the pumping unit components The hydraulic pump enclosure is weather tight and lockable Typical environmental operation is between 0 F and 110 F Typical enclosure is designed to provide a NEMA level 3R rating 1 1 17 Options The 611X series HPU s are available with a broad array of options and field installed kits Consult your ordering documentation to determine whether your system has the optional equipment Multiple manifolds to drive multi lane solutions Multi loop detection components for a variety of programmable modes of operation A traffic control gate ar
9. al Annual YES B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2
10. commend using environmentally safe oil such as Mobil EAL 224 Measure the resistance in any traffic loops and log the measurements and report anomalies if applicable Open the hydraulic oil tank in the HPU and inspect the oil for dirt or water When the inspection is complete turn the power on and test cycle the barrier to verify operation and control OO O D OOO 3 4 Annual Maintenance Inspections We recommend you perform the following inspections annually Perform all quarterly maintenance steps Replace the hydraulic fluid B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611X Series HPU MAINTENANCE 14 4 TROUBLESHOOTING The table below provides a general guidance on identifying and correcting any problems with your 611X Series HPU If you encounter problems that you cannot fix contact B amp B ARMR and we will gladly work with you to correct them 611x Series HPU Troubleshooting Guide The table below provides guidance on identifying and correcting any problems with your 611X series HPU Please refer to the barrier manual for more detailed troubleshooting guides If you encounter problems that you cannot fix contact B amp B ARMR and we will gladly work with you to correct them Symptom Actions 1 Check power 2 Check for binding between moving plate and frame Check connection of linkage between frame and plate Check for foreign debris 3
11. d D S XMTR Damas XMAN ADO3PO L 3 PH 3 HP XMAN AD03P02 LC OTs i XMTR 114615 00 XMAN ADO3PO3 1 PH 3 HP 003 04 XMTR 121060 00 MANIFOLD BLOCK lls v my N XPUMP G1220E SWi PSW PUMP PRESSURE 1 __ N XHYD 6 7AL 20 ACCUMULATOR XPUMP ow HAND PUM XH YO GAUGE Y PRESSURE GAUG Figure 1 Orients you to the basic components of the 6118 amp 6119 series HPU B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611X Series HPU ORIENTATION The HPU contains HIGH VOLTAGE components that can cause serious injury or death Only trained service technicians should attempt any repair Ensure at all times that proper safety lock outs barrier safety braces and all other safety systems are in place prior to any maintenance or service The HPU is a hydraulic system that can be under extreme pressure Caution should be used when working in and around unit without proper covers in place 1 1 1 Electrical Control Box The control box houses the electronic controls in the HPU The program installed in the PLC varies based on the barrier style and application The power switch should be turned off any time the unit is serviced Do not restore power to the unit until all traffic and pedestrians have been cleared from harm s way 1 1 2 Flow Control Valve The flow control valve s are located
12. ek ent EN 8 1 1 12 Electric Motori chon coh eh E A ip ips pene ERE 8 1 1 13 EFO Valve and Coil eee RE AR ee ees eI ee ae 8 1 1 14 Base Filter Assembly nieron etia ien DRM eee 8 1 1 15 Directional Control Valve sees ener nennen trennen rennen 9 1 1 16 dae a d etm dion ttes 9 1 1 17 Options caeco eto a eden iae RUN 9 2 OPERATION eR 9 24 Introduction beu net eed i ee tete die ded n dte ees 9 2 2 Control Signals i nen etn e n OR RE RE EE ERIT EI esd overs SEKE eles eee 9 2 3 Emergency Fast Operation EFO esses etre rennen tnne nene tree trente entren enne 9 2 4 Manual Operation p a RI E EO PER D ND E EO Pes 10 3 MATNTENA NCE eene eee eee ea Fe ege toan 11 AN 12 3 2 Monthly Inspections eom er e ERE RC ERR FERENT 12 3 9 Six Month InSpeCtiOnss e he epe di e i t dd qu etes 13 3 4 Annual Maintenance Inspections eese 13 4 TROUBLESHOOTING 14 41 61Ix Series Troubleshooting Guide essere nennen eene 14 5 WARRANT Y eoe beu sensus ue 16 6 APPENDIX sy snc RS QES tuaas tua Uveageveduasysvedudessxedvens 17 B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation
13. lectrical failure a manual hand pump is provided to enable the system to be pressurized to operate the unit once the directional control valve is shifted The valve should be shifted and then manually stroke the hand pump until the barrier has closed the roadway NOTE the manual pump is used in case of power loss when the barrier must be moved 1 1 9 Pressure gauge The pressure gauge shows the actual HPU system pressure Standard operations should be less than 2000 PSI If higher pressure is required please verify operation with B amp B ARMR technical support 1 1 10 Accumulator The accumulator acts as a pressure reservoir to store pressurized fluid The electric pump pressurizes the accumulator and the accumulator provides a high volume of pressurized fluid in a short period of time 1 1 11 Pump The pump is mechanically connected to the electric motor and provides the required pumping pressure to charge the accumulator The pump typically provides fluid at a rate of 2 GPM 1 1 12 Electric Motor The electric motor drives the hydraulic pump The 611x series HPUs are provided with a variety of motor voltages Ensure correct voltages prior to initial operation 1 1 13 EFO Valve and Coil The Emergency Fast Operation EFO valve bypasses the flow control circuit and allows the system to provide full flow at highest system pressure This operation is intended to move the barrier in the deployed position in a short amount of time All s
14. luding but not limited to unauthorized repairs improper installation installation not performed by BBRSS authorized personnel incoming supply power is outside the tolerance for the product failure to perform manufacturer s suggested preventative maintenance modifications misuse accident catastrophe neglect natural disaster are not under warranty The exclusive remedy for breach of any warranty by BBRSS shall be the repair or replacement at BBRSS s option of any defects in the equipment IN NO EVENT SHALL BBRSS BE LIABLE FOR CONSEQUENTIAL OR SPECIAL DAMAGES OR ANY KIND OF PERSONAL DAMAGES Except as provided herein BBRSS makes no warranties or representations to consumer or to anyone else and consumer hereby waives all liability against BBRSS as well as any other person for the design manufacture sale installation and or servicing of the Products THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE NO OTHER WARRANTIES EXIST Any modification or alteration by anyone other than BBRSS will render the warranty herein as null and void B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611x Series HPU WARRANTY 6 APPENDIX 6 1 Simplified Standard Hydraulic Diagram The following figure shows a typical hydraulic schematic for a 611 X HPU
15. m to warn the vehicle operator This arm is positioned in front of the gate and does not rise until the gate is fully open and it closes before the gate starts to close Red amber traffic lights The light remains red if the gate is in any position except fully open Infrared safety beams to detect pedestrian traffic or as an additional vehicle sensing device 2 OPERATION 2 1 Introduction The HPU is controlled via a variety of dry contact closures into the Programmable Logic Controller PLC Most common systems use a B amp B ARMR supplied control panel Please reference control panel user manual for specific control options 2 2 Control Signals The dry contact control signals are field connected based on optional equipment ordered per installation For a detailed point to point connection please refer to the site submittal prepared for the specific installation site 2 3 Emergency Fast Operation EFO Optional emergency fast operation enables the pump to provide all pressure and flow possible in the shortest amount of time EFO operation normally requires the user to provide a reset signal to the HPU to enable normal operation to continue B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611X Series HPU OPERATION 10 During EFO operation is it common for ALL safety signals to be bypassed to enable the barrier to close regardless of such safe
16. o make sure there is no hidden damage that will compromise safety or effectiveness and help you determine which components should be replaced 3 2 Monthly Inspections We recommend you perform the following visual inspections monthly on the barrier system An equipment maintenance log is supplied in the appendix to assist in the logging Inspect the condition of the finish If rust is present wire brush and sand the area then paint with a primer and a matching color Vacuum and clean the pumping unit area Check paint and touch up if required Check oil for level pressure and condition in the HPU Recommended oil Mobil EAL 224 If oil is contaminated report and recommend replacement immediately Recommended oil Mobil EAL 224 Replacement requires authorization Check barrier for operation through normal cycles Adjust barrier speed to ensure proper operation Check original submittal documents for normal operating speed for up and down During the opening and closing cycles verify the barrier operates smoothly and does not bind Also verify that the barrier does not hit with excessive force when it contacts its full open or full closed positions If necessary adjust the barrier s speed Check the hydraulic pumping unit for leaks at all points Visually inspect the operation and electrical contacts Tighten electrical contacts if required Check adjust and tighten all sensors limit switches proximity switches If applicable
17. on the manifold and are used to control the amount of flow of hydraulic fluid both to and from the barrier under control This in turn sets the speed of operation of the barrier The lower flow control valve controls how fast the gate travels while the upper control valve restricts how fast the barrier is opened 1 1 3 System relief Valve The system relief valve enables the system to be de pressurized during maintenance and service operations 1 1 4 Tank Weldment The tank reservoir holds the hydraulic fluid that is not under pressure The nominal capacity of the tank is 20 gallons 40 gallons on the 6117 B amp B ARMR recommends the use of environment friendly oil such as Mobil EAL 224 in all of our hydraulic systems 1 1 5 Oil Site Gauge The oil site gauge gives an easy indication of the fluid level in the reservoir tank without requiring the removal of the top cover 1 1 6 Manifold Block The main manifold block routes the pressurized hydraulic fluid to the various locations in the hydraulic system via control valves B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611X Series HPU ORIENTATION 1 1 7 Pressure Switch Adjustment of the pressure switch determines the system pressure This switch controls the motor to maintain the system pressure See pressure switch adjustment process to ensure proper system pressure 1 1 8 Hand Pump In case of e
18. ou are responsible for correct and safe installation operation and maintenance of this equipment Users must follow the specific instructions and safety precautions located in this manual In addition they must Follow the safety standards of the Occupational Safety and Health Administration OSHA as well as other applicable federal state and local safety regulations and industry standards and procedures For installation outside the United States users must also follow applicable international regional and local safety standards Engage only trained and experienced staff to install operate and maintain the equipment Ensure that all repairs are performed correctly using properly trained technicians and the correct tools and equipment This HPU comes with a power ON OFF switch Although this switch does cut the power to the motor and various other devices always use correct lock out and safety procedures when servicing the unit This unit is designed to be operated with the covers in place Extreme caution should be used when operating without covers Additional system safety devices may be included with this barrier system o Vehicle loop detector s Safety loop Traffic arms Traffic lights IR beams Safety edges O OO 0 B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611x Series HPU INTRODUCTION iv How to Contact Us If you have an
19. pressure reaches the desired level 6 Manually shift desired control valve by placing a small screwdriver or other pointed instrument on the solenoid end and push The B side of the valve deploys raises the barrier The A side of the valve stows lowers the barrier Figure 3 Model 6119 HPU without EFO Manifold 7 Multiple operations may require additional hand pumping to increase accumulator pressure 8 After power is restored turn pumping unit power back to the on position No additional changes are required 3 MAINTENANCE B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611X Series HPU MAINTENANCE 12 Do not attempt repairs unless you are trained and qualified This vehicle barrier can cause equipment damage and severe injury if it is operated or maintained improperly 3 1 Introduction The 611X Series HPUs are designed to be largely maintenance free As with any complex electromechanical device however they must be regularly inspected to ensure they are operating correctly We recommend a simple monthly visual inspection and a more thorough biannual inspection as described below Please contact B amp B ARMR Technical Service Support for assistance with inspections maintenance or repairs if needed Component damage is likely if a vehicle strikes the barrier If this occurs contact B amp B ARMR We can help you assess the damage t
20. sure relief valve is closed fully clockwise Check that the pressure switch is adjusted to shut the motor off before 1900 PSI Check for correct voltages Barrier moves too slowly Check for mechanical binds Check flow control valve In extreme cold temperatures a higher grade hydraulic fluid may be required to keep viscosity constant Traffic indicator light does not change N Check proper limit switch operation Check bulbs Check PLC outputs B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611x Series HPU WARRANTY 5 WARRANTY BBRSS warranties for a period of one 1 year FOB manufacturing facility unless otherwise specified by BBRSS in writing from defects due to faulty material or workmanship Damage due to handling during shipment and installation are not covered under warranty BBRSS assumes no responsibility for service at customer site BBRSS is in no event responsible for any labor costs under the warranty Subject to the above limitation all service parts and replacements necessary to maintain the equipment as warranted shall be furnished by others BBRSS shall not have any liability under these specifications other than for repair or replacement as described above for faulty product material or workmanship Equipment malfunction or equipment failure of any kind caused for any reason inc
21. ty devices EFO is recommended to be used in emergency situations only 2 4 Manual Operation The Model 611X series pumps are equipped with a manual hand pump to pressurize the accumulator and operate the barriers in case of power failure The following lists out the recommended sequence to operate the pump in a manual mode 1 Open door to HPU cabinet and identify the power switch pressure gauge manual hand pump and control valve s Your pumping unit may vary slightly from these illustrations Consult technical assistance if unsure of locations of these components HPU Power Switch L i ET Control Valve a Figure 2 Model 6119 HPU without EFO Manifold 2 Turn the power switch off to the unit to ensure pump system does not inadvertently turn on without warning on power restore 3 Verify area surrounding the barrier is clear of pedestrian traffic or other obstacles B amp B ARMR A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611X Series HPU OPERATION 11 Manual operation of the pump to raise and lower the barrier by pass all safety lockouts and switches Use extreme care when operating any barrier in the manual mode 4 Check pressure gauge on pump to determine if accumulator system has adequate pressure to raise the barrier 1500 1900 psi or greater 5 If pressure is less than barrier requirements operate the manual hand pump until
22. y questions or experience any problems with your vehicle barrier or if we can help you with any other facility security issues please contact us directly at B amp B ARMR Corporate Tech Support B amp B ARMR 2009 Chenault Drive Suite 114 Carrollton TX 75006 USA Telephone 972 385 7899 Toll Free 800 367 0387 Fax 972 385 9887 E mail info bb armr com techsupport bb armr com A Division of B amp B Roadway and Security Solutions 611XWB 9001 Revision B2 Installation and Operations Manual 611X Series HPU TABLE OF CONTENTS Table of Contents INTRODUCTION wissesivcsiccstecsassatvcatccitectsceniucaiecstnccacssancadcesticdanseacdvavestuccansusedsivceevedeueasd ii SAL OY ict paste RM NI ii Howto Contact US TT iv 1 6 1 1 1 Electrical Control Boxs sis sonde DB re pH RR eret eere 7 1 1 2 Flow Control VaVe nosep gene ieee GRON OD OI Oen oq eee 7 1 10 3 Systemrehet Valve eoo seseoososese ocn D BODIE ROO DRIED petet ee 7 114 Tank Weldent ean eese eb 7 LES OusSite Gauges eemper OEP EID DN 7 1 16 Blocks si cu seine cheetah OG meses elu EEG 7 1 1 Pressure Switch sospes A ap nt ata at NS 8 LS etl eg i ete iG en e ebd eiua REIS 8 LES Pressure gauge sped mop DS 8 1 1 10 Accumulator 5i mtesthen sue REUS ipse pe a ee 8 1 1 11 Pump Rien IeCDP Pee ets hs S