Home

PDF File

image

Contents

1. 42 9 C 89 6 F 109 2 F In Surface Temp mode 0 C 60 C 32 F 104 F 7 Precision 32 C 36 C 89 6 F 96 8 F 40 3 C 0 6 F 36 C 39C 96 8 F 102 2 F 0 2C 0 4 F 39C 42 9C 102 2 F 109 2 F 0 3 C 0 6 F 8 Consumption lt 150mW 9 Measuring distance 3cm 5cm 1 2in 2in 10 Automatic stop 30 sec LONGEVITY USE The SantaMedical RY210 is guaranteed for 40 000 takings X ADVICE The protective glass over the lens is the most important and fragile part of the thermometer please take great care of it Clean the glass with cotton fabric wet with 95 alcohol Do not use other batteries than mentioned batteries do not recharge non rechargeable batteries do not throw in fire Remove the batteries when thermometer is not used for an extended period of time An impact will damage the product XI ACCESSORIES SUPPLIED User manual in English 1 pc AA alkaline battery 2 pcs pouch 1 pc 14 XII TROUBLESHOOTING If you have one of the following problems while using your SantaMedical RY210 please refer to this breakdown service guide to help resolve the problem If the problem persists please contact our customer service The screen displays temperature superior to 95 The temperature is in Fahrenheit change the measurement to Celsius by pressing the Program Setting button to get the F1 function key The screen displays the body temperature inferior to 32 C 89 6 F To take a body temperature the function key F3 must
2. able to measure the temperature of a person by the energy the person emits This measurement can be taken thanks to an external temperature probe on the device which permanently analyses and registers the ambient temperature Therefore as soon as the operator holds the thermometer near the body and activates the radiation sensor the measurement is taken instantly by detection of the infrared heat generated by the arterial blood flow Body heat can therefore be measured without any interference from the heat of the surrounding environment THE DIFFERENT METHODS OF TEMPERATURE MEASUREMENT Core temperature Core temperature is the most precise measurement and involves measuring the temperature in the pulmonary artery by means of a catheter equipped with a thermal probe which can read the temperature in situ The same method is employed for probes measuring the oesophageal temperature However such invasive temperature measurement methods require specific equipment and expertise Rectal thermometry Rectal temperature adjusts slowly in comparison to the evolution of the body s internal temperature It has been demonstrated that rectal temperature remains raised long after the internal temperature of the patient has started to drop and vice versa Furthermore rectal perforations have been known to occur as a result of this method and without appropriate sterilization techniques rectal thermometry can spread germs often found in Faeces Oral t
3. be on Body mode If you re on Surface Temp mode the 32 C 89 6 F temperature displayed is showing the external temperature that your body releases The screen displays the message HI When using the SantaMedical RY210 the message HI can show on the screen The analysis is above the measurement range selected either superior to 42 9C 109 2 F in Body Mode or superior to 60C 140 F in Surface Temp Mode 15 THE SCREEN DISPLAYS THE MESSAGE LO When using the SantaMedical RY210 the message Lo can show on the screen The temperature analyzed is under the measuring range selected either less than 32 C 89 6 F in Body Mode or less than 0C 32 F in Surface Temp Mode This message displays in various cases please find below a list of the main cases Reasons for LO message display Temperature reading hampered by hair perspiration Make sure that there is no obstruction prior to taking a temperature Temperature hampered by an air flux Temperature readings too close together the RY210 did not have the chance to boot itself The measuring distance is too far Make sure there is no air flux as this could interfere with the infrared system Respect the pause of 15 seconds minimum between two readings 3 5 seconds pause is advised Please respect the measuring distance between 3 and 5 cm 1 2in and 2in 16
4. EMPORAL ARTERY TA TEMPERATUERE Infrared arterial temperature can be measured using a device placed on the forehead in the Temporal artery region It has been demonstrated that this relatively new method of measuring temperature is more precise than tympanic thermometry and better tolerated than rectal thermometry The SantaMedical RY210 thermometer has been designed to produce an instant forehead temperature reading without any contact with the temporal artery As artery is quite close to the surface of this skin and therefore accessible and given the blood flow is permanent and regular it allows precise measurement of the temperature This artery is linked to the heart by the carotid artery which is directly linked to the aorta It forms part of the main trunk of the arterial system The efficiency speed and comfort of taking a temperature from this area make it ideal compared with other temperature measurements methods NORMAL TEMPERATURES ACCORDING TO AGE Age ce E 0 2 years 36 4 38 0 97 5 100 4 3 10 years 36 1 7 8 97 0 100 0 11 65 years 35 9 37 6 96 6 99 7 gt 65 years 35 8 37 5 96 4 99 5 PRACTICAL CONSIDERATIONS WHEN TAKING A TEMPERATURE In order to ensure that precise and accurate temperature measurements are obtained it is essential that each user has received adequate information on and training in the temperature measurement technique when using such a device It is essential to remember that although procedures such a
5. SORIES SUPPLIED 222222 14 XII TROUBLESHOOTING 15 User Manual English V 00 I SAFETY PRECAUTIONS Follow the maintenance advice stipulated in this instruction manual This device may be used for professional purposes or for personal home use This device must only be used for the purposes described in this instruction manual This device must only be used at the ambient temperature range of between 10 and 40 This device must always be kept in a clean dry area Do not expose this thermometer to electric shocks Do not expose this thermometer to extreme temperature conditions of 50 C or lt 20 0 Do not use this device in relative humidity higher than 85 The protective glass over the lens is the most fragile part of the thermometer Do not touch the glass of the infrared lens with your fingers Clean the glass with a cotton bud lightly moistened with 95 alcohol Do not expose the thermometer to sunlight or to water Do not use this device outside Never drop the device Should a problem occur with your device please contact your retailer Do not attempt to repair this device yourself THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION TI INTRODUCTION The SantaMedical RY210 Non contact Infrared thermometer has been developed using latest infrared technology This technology allows temporal artery TA temperature to be taken at
6. SantaMedical Non contact Infrared Thermometer Model RY210 CONTENTS I SAFETY PRECAUTIONS sec 22022 a eee eee os i INTRODUCTION lt 2225 eee ae eea as 3 III PRECAUTIONS BEFORE USE 22 2 2 66 eb ere bee oe See eres 3 IV OPERATING PRINCIPLE ocooo oe soscscossrasrscos oss 4 THE DIFFERENT METHEODS OF TEMPERATURE MEASUREMENT 4 NORMAL TEMPERATURES ACCORDING TO MEASUREMENT METHOD 5 ADVANTAGES OF TEMPORAL ARTERY TA TEMPERATURE 6 NORMAL TEMPERATURE ACCORDING TO AGE 6 PRACTICAL CONSIDERATIONS WHEN TAKING A TEMPERATURE 6 HOW TO TAKE A TEMPERATURE lt lt lt 2 cs 7 CONSIRAINTS 0223 lp ia it ta jaa a 7 Y DESCRIPTION OF THE RY210 oa a e aa a 8 VI FUNCTIONS ea a a oe eS 10 VI USAGES 2 re a a et ee e iaa 10 VIH SETTING FUNCTION OF MENU etc ee te eer el ee eee ee 11 1 SWITCH ON THE DEVICE 2 ci tse oe cs iy sin ae Se a ea 11 2 CHOOSING THE TEMPERATURE UNIT F1 MENU 11 3 ALARM SETUP F2 MENU Woon ce eee eee ee oe ae oe Se eee ee 11 4 CHOICE OF DISPLAY MODE BODY OR SURFACE TEMP F3 MENU __ 41 5 TOTAL DIFFERENCE F4 MENU 5 gt gt 252222 is 12 6 BUZZER ON OFF F5 MENU oc Se ee re eee eee ee 13 7 EXITING THE SETTING MODE 222222 13 8 DATA MEMORY 2222 jo e a ens a 13 9 CHANGING THE BATTERIES ooo 13 IX TECHNICAL CHARACTERISTICS amp PRECISION ______z_o o 14 Ko ADVICE 520 sana aa 14 XI ACCES
7. a distance of about 3 5cm away from the forehead Precise Instantaneous and without Contact the RY210 is to date the most suitable thermometer for no risk temperature measurement It has been demonstrated that this method of TA temperature measurement is more precise than tympanic thermometry and better tolerated than rectal thermometry 1 However as with other types of thermometer it is essential to use the SantaMedical RY210 properly in order to obtain reliable and stable results You are therefore advised to read this instruction manual and the safety precautions carefully before use 1 Greenes D Fleisher G Accuracy of a Noninvasive Temporal Artery Thermometer for Use in Infants Arch Pediatr Adolesc Med 2001 155 376 III LPRECAUTIONS BEFORE USE The SantaMedical RY210 is pre set at the factory It is not necessary to calibrate the device when starting it up In order to obtain reliable and stable results you are advised each time there is a significant change in the ambient temperature due to a change in environment to allow the SantaMedical RY210 to acclimatize to this ambient temperature for 15 to 20 minutes before using it It is important to allow 3 5 seconds interval between two measurements IV OPERATING PRINCPLE All objects solid liquid or gas emit energy by radiation The intensity of this energy depends on the temperature of the object The SantaMedical RY210 Non contact infrared thermometer is therefore
8. e ambient temperature due to a change in environment to allow the to acclimatize to this ambient temperature for at least 15 minutes before using it V DESCRIPTION OF THE SantaMedical RY210 Infrared Lens LCD screen a Measuring key Se Battery compartment MENU BUTTON SETTING KEYS 1EC60417 5840 TRADEMARK Type B applied part WEEE VI FUNCTIONS 1 Specially designed to take the body temperature of a person regardless of the room temperature 2 Quick and reliable results as it uses the advantage infrared detection system 3 Sound alarm if temperature is exceeded 4 Memorize 32 measures 5 LCD backlit digital screen 6 Data displayed in Celsius or Fahrenheit 7 Automatic stop 30 seconds energy saver 8 Small convenient easy to use ADDITIONAL USAGE SantaMedical RY210 can also be used to measure the temperature of a baby bottle or bath or room temperature by using the Surface Temp function This function is in accordance with the Directive 89 336 EEC Electromagnetic Compatibility VII USAGE 1 Install battery 2 For the first usage or when inserting new batteries wait between 10 minutes for the warm up of the apparatus and when inserting the new batteries 3 Aim towards the forehead see the diagram below for the RY210 positioning from a distance of 3cm 5cm 1 2in 2in press the measuring key the temperature is displayed in 1 second The temperature can also be taken behind the ear lobe 4 Be
9. fore taking the temperature make sure to remove hair and perspiration from the forehead You can also take the temperature behind the ear lobe 10 VIII SETTING amp FUNCTION OF MENU MENU BUTTON SETTING KEYS 1 SWITCH ON THE DEVICE Press the Measuring key one second after the screen panel in full display it will enter the standby model with the sign C or F When then press the Measuring key again and get the measuring result in 2seconds But if there is no key to press it will turn off in 30 seconds automatically 2 CHOOSING THE TEMPERATURE UNIT F1 FUNCTION Press PROG SETTING button for 3 seconds the screen displays F1 Select for degrees Celsius for degrees Fahrenheit Confirm by pressing PROG SETTING button 3 ALARM SETUP F2 MENU Press PROG SETTING button for 3 seconds the screen displays F1 Press PROG SEETING button to get F2 Select to increase the threshold by 0 1 C 0 1 to reduce it by 0 100 177 Confirm by pressing PROG SETTING button Note The alarm threshold default value is 38 C 100 4 4 CHOICE OF DISPLAY MODE BODY OR SURFACE TEMP F3 MANU The SantaMedical RY210 is specially designed to take the body temperature of a human being FOR this use the BODY mode Measurement range for Body mode 32 C 42 9 C 89 6 109 2T gt 11 You can also use the SantaMedical RY210 to measure the temperature of an area or an object a food a liqu
10. hermometry Oral temperature is easily influenced by recent ingestion of food or drinks and by breathing through the mouth To measure oral temperature the mouth must remain closed and the tongue lowered for three to four minutes which is a difficult task for young children to accomplish Axillary armpit temperature Although it may be easy to measure axillay temperature it has been proven that it does not provide an accurate measurement of the child s internal temperature To take this type of temperature the thermometer must be wedged tightly over the axillary artery Despite the low sensitivity and relative inaccuracy of axillary temperature in detecting fever this method is recommended by The American Academy of Pediatrics as a screening test for fever in Newborns Tympanic thermometry In order to obtain a precise temperature reading good command of the measurement technique is required The thermometer probe must be placed as close as possible to the warmest part of the external ear canal An incorrectly placed probe could lead to a false temperature reading NORMAL TEMPERATURES ACCORDING TO MEASUREMENT METHEOD Measurement Method Normal temp Rectal 36 6 C 38 C Oral 95 5 C 3 5 0 Axillary 47 300 C Auriculay 35 8 C 38 C Temporal 35 8 C 37 8C The temperature of the human body varies throughout the day It can also be influenced by numerous external factors age sex type and thickness of skin ADVANTAGES OF T
11. id or a room temperature For this use the SURFACE TEMP mode Measurement range for Surface TEMP mode 0 C 60 C 32 F 140 F Press PROG SETTING button for 3 seconds the screen displays Fl Press PROG SETTING button twice to get F3 Select O by pressing button to get the BODY mode Select 1 by pressing button to get the SURFACE TEMP mode Confirm by pressing PROG SETTING button Note The SantaMedical RY210 is automatically set to BODY Important The area temperature differs from the internal body temperature To obtain the internal temperature always use the BODY mode Please make sure to select the BODY mode for an internal temperature reading and the SURFACE TEMP mode for an external area reading bottle bath Room 5 TATAL DIFFERENCE F4 MANU To adjust total variation of your SantaMedical RY210 Press PROG SETTING button for 3 seconds the screen displays Fl Press PROG SETTING button three times to get F4 Select to increase the difference by 0 1 C 0 1 to reduce it by 0 1C 0 1F Confirm by pressing PROG SETTING button If in doubt you are advised to leave the total variance at 0 0 C original setting Each time there is a significant change in the ambient temperature due to a change in environment to allow the RY210 to acclimatize to this ambient temperature for at least 15 minutes before using it 12 6 BUZZER ON OFF F5 MENU Press PROG SETTING button fo
12. r 3 seconds the screen displays Fl Press four times PROG SETTING button to get F5 Select to open the buzzer a sound icon is displayed on the LCD screen press to stop it the icon disappear Confirm by pressing PROG SETTING button 7 EXITING THE SETTING MODE Press PROG SETTING button until the screen turns off 8 DATA MEMORY To display the last temperature measurement press simultaneously the and button You will obtain the last temperature measurement To switch on the last measurement press the button The number indicated in interval of two measures corresponds to the number of measurements To exit data memory press the measure key The SantaMedical RY210 switches off in 30 seconds 9 CHANGING THE BATTERIES Display when the LCD screen displays Battery the battery is used Operation Open the lid and change the batteries taking great care with the correct positioning A mistake with could cause damage to the apparatus and compromise the guarantee of your SantaMedical RY210 Never use rechargeable batteries Use only batteries for single usage 13 IX TECHNICAL CHARACTERISTICS 1 Normal conditions of use Operating temperature 10 C 40 C 50 F 104 F Humidity rate lt 85 2 Power DC 3V 2 batteries AA 3 Package Size 200x145x50mm LxWxH 4 Unit Weight 136g without batteries 5 Display Resolution 0 1 C 0 1 F 6 Measuring range In Body mode 32 C
13. s taking a temperature may be simple they must not be trivialised Temperature should be taken in a neutral context The patient must not have undertaken vigorous physical activity prior to taking his her temperature and the room temperature must be moderate Be aware of physiological variations in temperature which must be taken into consideration when evaluating the results temperature increased by 0 5 C between 6am and 3pm Women have a temperature that is higher on average by around 0 2C Their temperature also varies in accordance with their ovarian cycle It rises by 0 5C in the second half of the cycle and at the early stages of pregnancy When sitting temperature is lower by about 0 3 to 0 4C than when standing HOW TO TAKE A TEMPERATURE Aim at the FOREHEAD over the right temporal region from a distance of about 3 5cm 1 2in 2in press the thermometer s measurement button and the temperature is instantly Displayed The reliability of the measurement cannot be guaranteed if the temperature is measured over another part of the body e g arm torso CONSTRAINTS Please observe the following before any temperature measurement to ensure a stable and reliable result Push back hair from the forehead Wipe away any perspiration from the forehead Avoid any drafts e g from nasal specs air conditioning Allow 3 5 seconds interval between two measurements Each time there is a significant change in th

Download Pdf Manuals