Home
S4787_Install Manual
Contents
1. 10 Close the housing 3 US Patent Numbers e 7 154 866 e 7 554 932 e 7 746 804 e Other patents pending 4 Specifications Housing 6 5 x 3 5 x 1 165 mm x 89 mm x 25 mm Weight 7 14 oz 204 g Operating environment All UL installations 32 to 140 F 0 to 60 C 90 relative humidity non condensing all other installations 4 to 140 F 20 to 60 C 90 relative humidity non condensing Power requirement 14 VAC 60 Hz 250 mA Battery capacity 3 6 VDC nominal 2900 mAh Typical back up battery life 24 hours Operating frequency 915 928 MHz Australia 921 928 MHz New Zealand 902 928 MHz USA Battery charger operating environment 32 to 140 F 0 to 60 C 90 relative humidity noncondensing Accessories ACC650 weatherproof plastic enclosure for outdoor installations BAT850 replacement lithium ion battery assembly UL certifications for EN5040 T UL 365 UL 636 UL 1023 ULC ORD C1023 74 UL 1076 UL 1610 UL certifications for EN5040 20T UL 2560 see conditions below Note For UL 2560 installations Inovonics repeaters must have 20 minute check in times Inovonics transmitters must have a minimum of 60 minute check in times Note For UL 2560 installations the EN5040 20T high power repeater may be used with completed emergency call systems for assisted living and independent living facilities For UL 2560 certified system installations the following Inovonics EchoStream devices are approved for ins
2. indoor use e All products should be manually tested weekly 2 2 Select the Frequency Band EchoStream devices are able to use a range of radio frequencies and must be configured for your geographic area This device ships with a default frequency range of 902 928 MHz for use in North America If you are using the device in North America skip to 2 3 Choose Messaging Mode if you are using the device in Australia or New Zealand you will need to configure it 1 Use a small screwdriver to press the top housing release tab and separate the housing Figure 2 2 Place a selection jumper on the frequency band selection pins appropriate to your geographic area Figure 2 e Place the jumper on the left two pins marked AU to set the frequency range to 915 928 MHz for Australia e Place the jumper on the right two pins marked NZ to set the frequency range to 921 928 MHz for New Zealand Note Only devices set for use in North America are configured for UL installations 2 3 Choose Messaging Mode The EchoStream commercial mesh network includes two kind of messaging broadcast messaging and directed messaging The high power repeater includes a messaging selection option to protect the integrity of your system The high power repeater ships with a default setting of broadcast messaging If you are installing the device in a broadcast messaging network skip to section 2 6 Register the High Power Repeater if you are installi
3. ce will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help 6 FCC Part 15 and Industry Canada Compliance This device complies with part 15 of the FCC Rules and Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement 7 Warranty Disclaimer Caution Changes or modifications not expressly approved by the party responsible for compliance co
4. e INOVONICS EN5040 EN5040 T EN5040 20T High Power Repeater with Transformer Installation and Operation Manual 1 Overview The Inovonics high power repeater receives decodes and retransmits signals at enhanced power from Inovonics devices It acts as a range expander for any valid Inovonics transmission including signals from other high power repeaters High power repeaters can be layered as necessary allowing Inovonics systems to scale from small commercial sites to complete campuses consisting of several buildings The high power repeater features AC power loss and jam detection as well as case tamper and wall tamper detection Input power is provided by listed class 2 transformer Good Power Electronics Ltd T48141428V010G or T48141428V020G MPI NEO Co Ltd W48A K1429 2T Note For UL 2560 installations refer to the EN6080 Area Control Gateway User Manual for other UL installations refer to the EN4216MR Installation and Operation Manual the EN4232MR Installation and Operation Manual or the EN7285 Installation Instructions 1 1 Maximum Number of Repeaters for a UL 2560 Installation To achieve the 99 99 alarm message reliability required for UL 2560 compliance system installations must operate within the following limits for end device and repeater counts Repeaters 1 2 Inovonics Contact Information If you have any problems with this procedure contact Inovonics technical services e E mail support inovonics c
5. emoved from metal Metal objects duct work wire mesh screens boxes will reduce RF range Caution In UL 2560 installations the unit must be mounted with the cable opening facing downward as shown in Figure 3 7 Use the provided anchors and screws to mount the high power repeater in a location accessible for future maintenance e In large installations high power repeaters should be mounted so that every transmitter has multiple transmission paths to the EN6080 area control gateway This kind of redundancy preserves system integrity in the event of temporary interruptions of any transmission path in the system e For maximum efficiency high power repeaters should be mounted with as few obstacles as possible between them and the EN6080 area control gateway e Always perform a walk test after mounting activating each transmitter assigned to the high power repeater and ensuring an appropriate response 2 8 Enable the Wall Tamper The wall tamper must be enabled If the high power repeater is removed from the wall the cutout on the back of the housing will detach activating a tamper alarm To enable the wall tamper 8 Attach one of the mounting screws to the wall through the tamper mounting hole Figure 2 2 9 Close the Housing The housing must be closed and the tamper spring in place to ensure the security of your system 9 Check that the tamper spring is in place and makes contact with the high power repeater housing
6. le from the backup battery into the battery connector Figure 2 2 6 Register the High Power Repeater Although the high power repeater is functional upon startup Inovonics strongly recommends you register it using the EN6080 area control gateway Inovonics recommends all high power repeaters be supervised When supervised the EN5040 and EN5040 T will send a check in message to the receiver every three minutes the EN5040 20T will send a check in message every 20 minutes Note In UL 2560 installations the repeater sends a check in message every 20 minutes Note Registration and supervision is required for UL installations Note In UL 2560 installations refer to the EN6080 Area Control Gateway User Manual for registration information in other UL installations refer to the EN4216MR Installation and Operation Manual the EN4232MR Installation and Operation Manual or the EN7285 Installation Instructions Caution The reset bit will not be sent when the high power repeater has a low battery Before registering the high power repeater ensure the battery is fully charged 2 7 Mount the High Power Repeater For best results you will want to mount the high power repeater vertically so that the antennae are oriented as shown in Figure 3 Antenna Antenna Figure 3 High power repeater antenna orientation 1 23 14 O5066N Inovonics 2014 www inovonics com Caution Mount the high power repeater in a location r
7. ng the high power repeater in a directed messaging network you will need to configure it 3 To set the high power repeater to directed messaging remove the selection jumper installed on the messaging mode selection pins 2 4 Connect Power Cabling Power must be connected to the high power repeater To connect power to the high power repeater 4 Use a small screwdriver to press the housing release tab on the top or bottom of the high power repeater Figure 2 separate the housing 5 Connect power cabling Figure 2 e Wire should be two conductor 20AWG or larger stranded tinned copper with PVC insulation rated to 300 volts at 26 C 80 F Wire length should not exceed 100 meters 328 feet Note For all UL installations cabling must be UL Listed or Recognized Class 2 wire suitable for the application Use two conductor 20 AWG or larger stranded tinned copper rated 300 volts 60 C minimum Wire length should not exceed 100 meters e See section 1 Overview on page 1 for approved Class 2 transformers e Route the cable from the transformer to the unit through the left side of the repeater or through the oval knock out section in the rear e Torque screw terminal to 0 25 N m 2 18 lb in Note Do not secure transformer for Canadian installations 2 5 Connect Battery Power The high power repeater is shipped with a fully charged backup battery You will need to connect the battery 6 Plug the connector cab
8. om e Phone 800 782 2709 303 939 9336 1 3 High Power Repeater Front Panel B i A So pa Figure 1 High power repeater front panel A Decode LED B Transmit LED C Low Battery Fault LED D Power LED Operation LEDs lt 5 Iinovonics Decode LED Flashes when any recognizable RF transmission is received Transmit LED Lit when transmitting an RF transmission Low Battery Fault LED Lit when the high power repeater has a low battery Power LED Lit when receiving power The LED lights green when the unit is receiving line power red when receiving battery power Note If mapped to an output the high power repeater will send the AC loss message to the EN6080 area control gateway when receiving power from the backup battery 1 23 14 O5066N Inovonics 2014 www inovonics com 1 4 High Power Repeater Internal Components Figure 2 High power repeater internal components A Housing release B Tamper button C Power D Tamper input tabs spring E Reset button F Backup battery G Battery H Tamper connector mounting hole J Messaging mode Frequency selection pins selection pins 1 5 What s in the Carton e One 14VAC 120VAC 20VA power transformer e Three drywall anchors e Three mounting screws e One frequency band selection jumper 2 Installation and Startup 2 1 Installation Notes e These products are designed to be maintained by professional security technicians e Products are tested for
9. tallation within maximum system configuration limits defined in section 1 1 of this document e EN6080 area control gateway e EN5040 20T high power repeater e End devices transmitters with a minimum 60 minute check in interval as follows Fundamental devices which are subject to UL2560 certification pendant transmitters and OEM products using the Inovonics RF module Supplemental devices which are not subject to UL2560 system certification but which may be used within a UL2560 certified system e g universal transmitters and activity sensors Note Users that have achieved certification and will install UL 2560 certified systems are responsible for labeling all fundamental devices with the UL 2560 system certification mark Compatible receiver for UL 2560 installations EN6080 area control gateway Compatible receiver for all other UL installations EN4216MR EN4232MR EN7285 US patent number 7 746 804 5 Television and Radio Interference This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interferen
10. uld void the user s authority to operate the equipment Inovonics Wireless Corporation Inovonics warrants its products Product or Products to conform to its own specifications and to be free of defects in materials and workmanship under normal use for a period of thirty six 36 months from the date of manufacture Within the warranty period Inovonics will repair or replace at its option all or any part of the warranted Product Inovonics will not be responsible for dismantling and or reinstallation charges To exercise the warranty the User User Installer or Consumer must work directly through their authorized distributor who will be given a Return Material Authorization RMA number by Inovonics Details of shipment will be arranged directly through the authorized distributor This warranty is void in cases of improper installation misuse failure to follow installation and operating instructions alteration accident or tampering and repair by anyone other than Inovonics This warranty is exclusive and expressly in lieu of all other warranties obligations or liabilities whether written oral express or implied There is no warranty by Inovonics that Inovonics product will be merchantable or fit for any particular purpose nor is there any other warranty expressed or implied except as such is expressly set forth herein In no event shall Inovonics be liable for an incidental consequential indirect special or e
11. xemplary damages including but not limited to loss of profit revenue or contract loss of use cost of down time or interruption of business nor any claim made by distributor s customers or any other person or entity This warranty will not be modified or extended Inovonics does not authorize any person to act on its behalf to modify or extend this warranty 1 23 14 05066N Inovonics 2014 www inovonics com This warranty will apply only to Inovonics Products Inovonics will not be liable for any direct incidental or consequential damage or loss whatsoever caused by the malfunction of Product due to products accessories or attachments of other manufacturers including batteries used in conjunction with Inovonics Products Note E mail support inovonics com for a copy of the CE Declaration of Conformity
Download Pdf Manuals
Related Search
Related Contents
OpenCL™ Optimization Guide Acu-Rite Weather Radio 1515 User's Manual LiftMaster, 195LM, 195LMC, montage au plafond, manuel d`installation Handbuch - Opel Schweiz Samsung ProXpress M3325ND Черно бял Лазерен Принтер(33 стр.за мин.) Наръчник за потребителя Windows Manual de instrucciones de red KP235 BENUTZERHANDBUCH KP235 Copyright © All rights reserved.