Home
85062 (Rev. D) 10946 Yellow Jacket SRL small
Contents
1. gt GUARDIAN FALL PROTECTION PERFORMANCE SAFETY GEAR Installation and Use Guardian Fall Protection Yellow Jacket SRLs MUST NEVER be used in Leading Edge LE applications unless possessing an integral shock absorber or used with a compatible shock absorber extension Shock absorber end MUST be connected to harness No free fall is allowed without shock absorber MAXIMUM 2 free fall in LE applications ALWAYS avoid lifeline contact with sharp or abrasive edges and surfaces In Fall Arrest applications anchorage connection point must always be at or above harness dorsal D ring AND at or below anchorage connector For LE applications MAXIMUM 2 below harness dorsal D ring or 2 above anchorage connector 1 All components of the personal fall arrest system must be selected and deemed compatible with Yellow Jacket SRL by a Competent Person 2 Ensure structure to which SRL is to be attached and on which work is to be performed is free of all hazards including but not limited to debris rot rust sharp or abrasive edges and surfaces and hazardous materials 3 Yellow Jacket SRLs may be used in either mobile or stationary applications 4 For mobile applications attach compatible carabiner to Yellow Jacket Carabiner Connection Point then to harness D ring compatible with the application Attach snap hook or rebar hook to compatible anchorage connector NEVER work so that SRL is positioned above anchorage point 5
2. For stationary applications attach compatible carabiner to Yellow Jacket Carabiner Connection Point then to a compatible anchorage connector Attach SRL snap hook to harness D ring compatible with the application NEVER work so that applicable harness D ring is positioned above anchorage point unless using shock absorber extension If using SRL with rebar hook configuration SRL carabiner must ALWAYS be attached to harness dorsal D ring and rebar hook must ALWAYS be connected to compatible structural rebar 6 Ensure 100 tie off will be maintained at all times which may require the use of a back up or supplementary fall protection system GUARDIAN FALL PROTECTION PERFORMANCE SAFETY GEAR LE SRL Additional Use Instructions WARNING ALWAYS adhere to the following warnings and specifications when using LE SRLs When used in combination with a compatible shock absorber extension Yellow Jacket SRLs are tested and certified for horizontal use over a steel edge without burrs Yellow Jacket SRLs may be used over similar surfaces such as metal sheeting or other steel formations The allowable angle of redirection of the lifeline portion of Yellow Jacket SRLs at the leading edge of a fall hazard MUST be at least 90 see Image 1 Anchor point MUST be situated no lower than the leading edge of applicable fall hazard s Prior to use a Competent Person MUST calculate adequate fall clearance see pg 7 ALWAYS attach to anchorage conne
3. Jacket SRL and all fall safety equipment used in combination with the Yellow Jacket SRL GUARDIAN FALL PROTECTION PERFORMANCE SAFETY GEAR User Information Date of First Use Serial Trainer User Applicable Safety Standards When used according to instruction specifications this product meets or exceeds all applicable OSHA 1926 Subpart M OSHA 1910 ANSI Z359 14 2012 and ANSI A10 32 2012 standards for fall protection Applicable standards and regulations depend on the type of work being done and also might include state regulations if applicable Consult regulatory agencies for more information on personal fall arrest systems and associated components Worker Classifications Understand the following definitions of those who work near or who may be exposed to fall hazards Qualified Person A person with an accredited degree or certification and with extensive experience or sufficient professional standing who is considered proficient in planning and reviewing the conformity of fall protection and rescue systems Competent Person A highly trained and experienced person who is ASSIGNED BY THE EMPLOYER to be responsible for all elements of a fall safety program including but not limited to its regulation management and application A person who is proficient in identifying existing and predictable fall hazards and who has the authority to stop work in order to eliminate hazards Authorized Person A person wh
4. gt GUARDIAN FALL PROTECTION PERFORMANGE SAFETY GEAR Product Name Yellow Jacket SRL Part 10946 10950 10952 10956 Instruction Manual Do not throw away these instructions Read and understand these instructions before using equipment www quardianfall com CN ON oe Pe Oo Ne Ne TN Oo oe Ses x lt gu em LA oe AA Ne 1 Ne Ne st NS Oo Oo oe Ses a Oo es an 6305 S 231st St Kent WA 98032 Guardian Fall Protection gt GUARDIAN FALL PROTECTION PERFORMANCE SAFETY GEAR Table of Contents Introduction 0 T2 Applicable Safety Standards 0 0 _ 2 Worker Classifications 2 0 ee ee eek 2 Safety Information 00 3 4 Maintenance Cleaning and Storage _ 5 Inspection 2 222222 LL LLL LLL Lt 5 Product Specific Applications 000 6 bl ee es ee es oy ees een E 1 9 Components and Specifications 2 2222 10 Installation and Use tn a kn a a a at 11 12 Labels ec ee m een ee ee eee a ee 0 13 MVS COT LOG ps re 14 NN 14 Introduction Thank you for purchasing a Guardian Fall Protection Yellow Jacket SRL This manual must be read and understood in its entirety and used as part of an employee training program as required by OSHA or any applicable state agency This and any other included instructions must be made available to the user of the equipment The user must understand how to safely and effectively use the Yellow
5. the leading edge Y the working distance X is 8 in each direction from the perpendicular which translates to a 53 working angle Key X Working Distance Along Roof Edge Y Distance From Leading Edge Total Working Angle gt GUARDIAN FALL PROTECTION PERFORMANCE SAFETY GEAR Components and Specifications Made from aluminum galvanized steel stainless steel zinc coated steel and high strength polycarbonate components K Carabiner Lifeline Connection Point Example Impact Indicator e Green Undeployed e Red Deployed rae l Lifeline Housing lt lt Connector Available with either snap hook or rebar hook Carabiner Installation Location V Shock Absorber 10946 Connector Cable Housing Lifeline 10946 10 Heavy Duty Yellow Jacket Cable SRL w Shock Pack 10952 10 Yellow Jacket Cable SRL w Aluminum Rebar Hook 10956 10 Yellow Jacket Cable SRL w High Strength Indicating Snap Hook www quardianfall com CN ON oe De Oo De Ne Oo Oo oe xr gt DO fo LO oe M Ne I Ne Ne ST Oo Oo oe Ner a Oo S a amp 6305 S 231st St Kent WA 98032 Guardian Fall Protection www quardianfall com CN ON oe ie Oo Ne Ne Damn oe xr gt DO a LA oe M Ne I Ne Ne st Damn Oo Oo oe xr a d an 6305 S 231st St Kent WA 98032 Guardian Fall Protection
6. CTION PERFORMANCE SAFETY GEAR Maintenance Cleaning and Storage Repairs to Yellow Jacket SRLs can only be made by a Guardian Fall Protection representative or an entity authorized by Guardian Contact Guardian for all maintenance and repair needs at 1 800 466 6385 If a Yellow Jacket SRL fails inspection in any way immediately remove it from service and contact Guardian to inquire about its return or repair Cleaning after use is important for maintaining the safety and longevity of Yellow Jacket SRLs Remove all dirt corrosives and contaminants from Yellow Jacket SRLs before and after each use If a Yellow Jacket SRL cannot be cleaned with plain water use mild soap and water then rinse and wipe dry NEVER clean Yellow Jacket SRLs with corrosive substances When not in use store equipment where it will not be affected by heat light excessive moisture chemicals or other degrading elements Inspection KEEP INSTRUCTIONS AVAILABLE FOR REFERENCE Record date of First Use Prior to EACH use inspect SRLs for deficiencies including but not limited to corrosion deformation pits burrs rough surfaces sharp edges cracking rust paint buildup excessive heating alteration fraying bird caging and missing or illegible labels Inspect full length of lifeline IMMEDIATELY remove SRL from service if defects or damage are found Prior to EACH use check lifeline retraction by pulling out a minimum 4 and allowing it to retract un
7. ROTECTION PERFORMANCE SAFETY GEAR Inspection Log User must inspect prior to EACH use Competent Person other than user must complete formal inspection at least every 6 months Competent Person to inspect and initial Date of First Use Product lifetime is indefinite as long as it passes pre use and Competent Person inspections This inspection log must be specific to one Yellow Jacket SRL Separate inspection logs must be used for each Yellow Jacket SRL All inspection records must be made visible and available to all users at all times If equipment fails inspection IMMEDIATELY REMOVE FROM SERVICE Notes www quardianfall com CN ON oe De Oo De Ne Oo Oo oe xr gt DO fo LA oe M Ne I Ne Ne lt AN Oo Oo oe Se a Oo S a amp 6305 S 231st St Kent WA 98032 Guardian Fall Protection
8. ble D ring Dorsal Standard applications No free fall is permitted SRL must always be positioned at or above harness dorsal D ring AND at or below anchor point e Leading Edge LE applications Shock absorber required Maximum 2 free fall SRL may be positioned a maximum 2 below harness dorsal D ring If intending to use Yellow Jacket SRL in LE applications refer to additional LE SRL use instructions pg 12 Restraint Yellow Jacket SRLs may be used in Restraint applications Restraint systems prevent workers from reaching the leading edge of a fall hazard Always account for fully deployed length of SRL Structure must withstand loads applied in the directions permitted by the system of at least 1 000 Ibs No free fall is permitted Restraint systems may only be used on surfaces with slopes up to 4 12 vertical horizontal Applicable D rings Dorsal Chest Side Shoulder For all applications worker weight capacity range including all clothing tools and equipment is 130 310 Ibs or up to 420 Ibs if deemed permissible by a Competent Person and used in combination with equipment explicitly certified for such use www quardianfall com CN ON oe ie Oo De Ne Oo Oo oe xr gt DO fo LA oe AA Ne I Ne Ne ST Oo Oo oe Ner a Oo Sa m 6305 S 231st St Kent WA 98032 Guardian Fall Protection www quardianfall com CN ON oe Pe Oo De Ne TN oe x
9. ctor that will allow for required setback distance see Image 2 Setback distance As determined by product testing Guardian Fall Protection Yellow Jacket SRLs MUST be installed a MINIMUM 6 1 8m from the leading edge of applicable fall hazard s Yellow Jacket SRLs may be used in combination with horizontal lifelines All installation set up and use of horizontal lifelines must be done under the supervision of a Qualified Person NEVER work on the far side of an opening that is opposite the Yellow Jacket SRL anchorage point In the event of a fall over the edge special rescue measures may be necessary Always account for use of Yellow Jacket SRLs in job site rescue plan developed by job site Competent Person Setback Distance image 1 Image 2 www quardianfall com CN ON oe De Oo De Ne Oo Oo oe xr gt DO fo LO oe M Ne I Ne Ne ST Oo Oo oe Ner a Oo S a amp 6305 S 231st St Kent WA 98032 Guardian Fall Protection gt GUARDIAN FALL PROTECTION PERFORMANCE SAFETY GEAR www quardianfall com 10 CABLE HD 10 CABLE HS 10 CABLE 10 CABLE HS SHOCK PACK SWIVEL SH ALUMINUM RH NON INDIC SH CUSTOM 10946 10950 10952 10956 ste maim s salstol n o J Pt tt TG YR phone 800 466 6385 fax 800 670 7892 6305 S 231st St Kent WA 98032 Oo 5 a fr GQ ee pe UO DO D gt GUARDIAN FALL P
10. der light tension lifeline must retract completely Pull lifeline sharply to test braking function brakes must engage Check shock pack for signs of deployment and or fall arrest indicator for signs of activation Fall arrest indicator will display red if activated IMMEDIATELY remove from service if SRL does not function properly or if there exists any evidence of exposure to forces of fall arrest Ensure that applicable work area is free of all damage including but not limited to debris rot rust decay cracking and hazardous materials Ensure that selected work area will support the application specific minimum loads set forth in this instruction manual Work area MUST be stable Competent Person other than the user must inspect SRLs AT LEAST every 6 months Competent Person inspections MUST be recorded in inspection log in instruction manual and on equipment inspection grid label The Competent Person must sign their initials in the box corresponding to the month and year the inspection took place During inspection consider all applications and hazards SRLs have been subjected to GUARDIAN FALL PROTECTION PERFORMANCE SAFETY GEAR Product Specific Applications Personal Fall Arrest Yellow Jacket SRLs may be used in Personal Fall Arrest applications as a component of a MAXIMUM 1 Personal Fall Arrest System PFAS Structure must withstand loads applied in the directions permitted by the system of at least 5 000 Ibs Applica
11. here workers will be performing their duties the routes they will take to reach their work and the potential and existing fall hazards they may be exposed to Fall protection equipment must be chosen by a Competent Person Selections must account for all potential hazardous workplace conditions All fall protection equipment should be purchased new and in an unused condition Fall protection systems must be selected and installed under the supervision of a Competent Person and used in a compliant manner Fall protection systems must be designed in a manner compliant with all federal state and safety regulations Unless explicitly stated otherwise the maximum allowable free fall distance for lanyards must not exceed 6 No free fall allowed for non LE SRLs SRLs must arrest falls within 54 Forces applied to anchors must be calculated by a Competent Person Harnesses and connectors selected must be compliant with manufacturer s instructions and must be of compatible size and configuration A pre planned rescue procedure in the case of a fall is required The rescue plan must be project specific The rescue plan must allow for employees to rescue themselves or provide an alternative means for their prompt rescue Store rescue equipment in an easily accessible and clearly marked area Training of Authorized Persons to correctly erect disassemble inspect maintain store and use equipment must be provided by a Competent Per
12. nce between a hook and the attachment point causes the hook gate to unintentionally open and release All connections must be selected and deemed compatible with Yellow Jacket SRLs by a Competent Person All connector gates must be self closing and self locking and withstand minimum loads of 3 600 Ibs See the following for examples of compatible incompatible connections Connector closed and locked to D ring OK Two or more snap hooks or carabiners connected to each other NO Two connectors to same D ring NO Incompatible or irregular application which may increase risk of roll out NO Connector to integral lanyard NO Connector directly to webbing NO Application that places load on gate NO Connector directly to horizontal lifeline NO www quardianfall com CN ON oe Pe Oo De Ne Oo Oo oe xr gt L oe op Ne I Ne Ne SF N Oo oe Ses a Oo omr amp 6305 S 231st St Kent WA 98032 Guardian Fall Protection GUARDIAN FALL PROTECTION Correct Anchorage Positioning This chart details allowable working zones required to reduce risk of swing falls and improper side loading ALWAYS adhere to information specified by chart Anchor Distance Working Distance Working Angle From Along Roof Edge From Leading Edge Y Either Direction X Perpendicular For example if the anchorage connector is 6 from
13. o is assigned by their employer to work around or be subject to potential or existing fall hazards It is the responsibility of a Qualified or Competent person to supervise the job site and ensure all applicable safety regulations are complied with www quardianfall com CN ON oe De Oo De Ne N e a oe xr gt DO fo LO oe M Ne I Ne Ne ST Oo Oo oe Ner a Oo S a amp 6305 S 231st St Kent WA 98032 Guardian Fall Protection www quardianfall com CN ON oe ne Oo De Ne PN Oo oe xr gt DO Nahe LA oe M Ne I Ne Ne st Damn Oo Oo oe xr a Oo d an 6305 S 231st St Kent WA 98032 Guardian Fall Protection gt GUARDIAN FALL PROTECTION PERFORMANCE SAFETY GEAR Safety Information Failure to understand and comply with safety regulations may result in serious injury or death Regulations included herein are not all inclusive are for reference only and are not intended to replace a Competent Person s judgement or knowledge of federal or state standards Do not alter equipment Do not misuse equipment Workplace conditions including but not limited to flame corrosive chemicals electrical shock sharp objects machinery abrasive substances weather conditions and uneven surfaces must be assessed by a Competent Person before fall protection equipment is selected The analysis of the workplace must anticipate w
14. r x lt em LA oe mm Ne 1 Ne Ne st NS Oo Oo oe Ses a Oo Ma an 6305 S 231st St Kent WA 98032 Guardian Fall Protection gt GUARDIAN FALL PROTECTION PERFORMANCE SAFETY GEAR Limitations Fall Clearance There must be sufficient clearance below the anchorage connector to arrest a fall before the user strikes the ground or an obstruction When calculating fall clearance account for a MINIMUM 3 safety factor deceleration distance user height length of lanyard SRL and all other applicable factors Diagram shown is an example fall clearance calculation ONLY FALL CLEARANCE CALCULATION Lanyard length 6 total Seen fe Deceleration gt q distance 4 total distance from anchorage 19 total Height of harness dorsal D ring from worker s feet 6 total L Safety factor 3 total Swing Falls Prior to installation or use make considerations for eliminating or minimizing all swing fall hazards Swing falls occur when the anchor is not directly above the location where a fall occurs Always work as close to in line with the anchor point as possible Swing falls significantly increase the likelihood of serious injury or death in the event of a fall gt GUARDIAN FALL PROTECTION PERFORMANCE SAFETY GEAR Compatibility When making connections with Yellow Jacket SRLs eliminate all possibility of roll out Roll out occurs when interfere
15. son Training must include the ability to recognize fall hazards minimize the likelihood of fall hazards and the correct use of personal fall arrest systems GUARDIAN FALL PROTECTION PERFORMANCE SAFETY GEAR NEVER use fall protection equipment of any kind to hang lift support or hoist tools or equipment unless explicitly certified for such use Maintenance of equipment must be done according to manufacturer s instructions Equipment instructions must be retained for reference Prior to EACH use all equipment in a fall protection system must be inspected for any potential or existing deficiencies that may result in its failure or reduced functionality IMMEDIATELY remove equipment from service if any deficiencies are found Equipment must be inspected by a Competent Person at least every six months These inspections must be documented in equipment instruction manual and on equipment inspection grid label Equipment must be inspected for defects including but not limited to the absence of required labels or markings improper form fit function evidence of cracks sharp edges deformation corrosion excessive heating alteration excessive wear fraying knotting abrasion and absence of parts Equipment that fails inspection in any way must immediately be removed from use or repaired by an entity approved by the manufacturer No on site repair of equipment unless explicitly permitted by Guardian Fall Protection Equipment s
16. ubjected to forces of fall arrest must immediately be removed from use Snap hooks carabiners and other connectors must be selected and applied in a compatible fashion All risk of disengagement must be eliminated All snap hooks and carabiners must be self locking and self closing and must never be connected to each other Age fitness and health conditions can seriously affect the worker should a fall occur Consult a doctor if there is any reason to doubt a user s ability to withstand and safely absorb fall arrest forces or perform set up of equipment Pregnant women and minors must not use this equipment Physical harm may still occur even if fall safety equipment functions correctly Sustained post fall Suspension may result in serious injury or death Use trauma relief straps to reduce the effects of Suspension trauma Allowable individual worker weight limit including all equipment unless explicitly stated otherwise is 130 310 Ibs www quardianfall com CN ON oe De Oo De Ne Oo Oo oe xr gt DO fo LO oe M Ne I Ne Ne ST Oo Oo oe Ner a Oo S a amp 6305 S 231st St Kent WA 98032 Guardian Fall Protection www quardianfall com CN ON oe ne Oo Ne Ne Damn Oo oe xr gt ae Nahe LA oe M Ne I Ne Ne st Damn Oo Oo oe xr a d an 6305 S 231st St Kent WA 98032 Guardian Fall Protection GUARDIAN FALL PROTE