1. Use on Dimmer S Auto Programs Y Outdoor Use S Auto ranging Power Supply vA Sound Activated S Replaceable Fuse S DMX Vv User Serviceable S Master Slave Y Duty Cycle S e One COLORdash Accent UV or COLORdash Accent VW e One Quick Reference Guide e One Warranty Card e 1 or 2 channel DMX UV LED wash fixture e Operating modes l channel Dimmer 2 channel Dimmer strobe e High power 1 W 350 mA LEDs 7 UV 395 410 nm e 2 3 or 5 channel DMX VW LED wash fixture e Operating modes 2 channel Warm white cool white 2 channel Dimmer white macros 3 channel Dimmer warm white cool white 5 channel Dimmer warm white cool white white macros strobe e High power 1 W 350 mA LEDs 3 cool white 4 warm white e Master or slave operation e Automatic programs e Static color control without DMX controller e Cast aluminum black housing e Adjustable double bracket e COLOR CON COLORdash Accent UV Order Code COLORDASHACCENTUV COLORdash Accent VW Order Code COLORDASHACCENT VW Page 2 of 8 COLORdash Accent VW DMX Channel Values S1 DS Channel Function Value Percent Setting 1 Dimmer 000 255 0 100 2 Warm White 000 255 0 100 3 Cool White 000 255 0 100 000 010 No Function 011 050 White 1 3 200 K A 051 080 White 2 3 400 K 4 White Macros 981 amp 110 White 3 4 200 K 111 140 White 4 4 900 K 141 255 White 5 5 600 K
2. Use the table below if you need to change the plug or to adapt the power connection to your particular market or installation Connection Wire US Wire Europe Screw Color AC Live Black Brown Yellow Brass AC Neutral White Blue Silver AC Ground Green Yellow Green Yellow Green These products have a DMX cord with a Y splitter on one end which has two 3 pin XLR connectors one male and the other female The other end of the DMX cable is hard wired to the unit The COLORdash Accent UV and VW can operate with either a DMX or a COLOR CON controller Use the standard DMX connection to connect these products to any of those controllers For more information please see the corresponding user s manual The COLORdash Accent UV and VW can work as stand alone units or as masters of a series of other similar units See the corresponding user s manual for more information Page 3 of 8 COLORdash Accent UV amp VW QRG COLORdash Accent UV amp VW QRG Control Options DIP Switch Summary DIP Switch Assignment Operation Modes Table The COLORdash Accent UV and VW can operate in DMX mode AUTO mode STATIC mode and SLAVE mode You can select any of these modes by using the DIP switches on the back of the unit see the Operation Modes Table below When configured for AUTO mode these products become the Master of a Master Slave configuration When configured for SLAVE mode they can work w
3. to ON ON ol 23 45 6 7 8 9 10 1112 b To select AUTO program 9 set DIP switches 1 4 and 12 to ON poe 10 11 12 When selecting the STATIC mode you can set the COLORdash Accent UV and VW fixtures to various luminous intensities without a DMX controller by using DIP switches 1 through 4 as per the table below COLORdash Accent UV amp VW QRG COLORdash Accent gt VW UV Color gt Warm White Cool White Ultra Violet Luminous Intensity DS1 DS2 DS3 DS 4 DS1 DS2 0 OFF OFF OFF OFF OFF OFF 30 ON OFF ON OFF ON OFF 60 OFF ON OFF ON OFF ON 100 ON ON ON ON ON ON 1 Set DIP switches 10 and 12 to ON and DIP switch 11 to OFF to select STATIC Mode 2 Select the color intensity as indicated in the STATIC Mode DIP Switch Values table Page 6 of 8 Mounting Product Mounting Diagram AC Power Power Wiring Power Cord Table DMX Connection DMX and COLOR CON Controllers Master Slave Connection Before mounting any of these products read the safety notes at the beginning of the corresponding user s manual and follow the mounting procedure indicated there These products have an auto ranging power supply that can work with an input voltage range of 100 240 VAC 50 60 Hz These products come with a power cord that has an Edison plug US amp Canada on one end while the other end is hardwired to the unit
4. Modes Table in page 4 2 Select the desired starting address 0 to 512 by setting DIP switches 1 through 9 to ON or OFF until the sum of the value of the DIP switches in the ON position matches the desired address number 3 Refer to the examples below for more information These three examples are for STD D DMX mode Therefore in all three cases DIP switches 10 11 and 12 are set to OFF a To select DMX Address 1 set DIP switch 1 to ON ON i 2345 6 7 8 9 10 1112 b To select DMX Address 64 set DIP switch 7 to ON ON eel 23 45 67 8 9 10 1112 c To select DMX Address 31 set DIP switches 1 2 3 4 and 5 to ON 14 2 4 4 8 4 16 31 ON MERET i m m i m m 2 345 6 7 8 9 10 1112 Page 4 of 8 Page 5 of 8
5. 5 Strobe 000 amp 255 0 100 STD W Channel Function Value Percent Setting 1 Warm White 000 255 0 100 2 Cool White 000 255 0 100 STD D Channel Function Value Percent Setting 1 Dimmer 000 255 0 100 2 Warm White 000 255 0 100 3 Cool White 000 255 0 100 STD 1 Channel Function Value Percent Setting 1 Dimmer 000 255 0 100 000 010 No Function 011 amp 050 White 1 3 200 K R 051 080 White 2 3 400 K 2 White Macros 981 amp 110 White 3 4 200 K 111 140 White 4 4 900 K 141 255 White 5 5 600 K Page 7 of 8 COLORdash Accent UV amp VW QRG AUTO Mode AUTO Mode DIP Switch Values Procedure Auto Mode Examples STATIC Mode STATIC Mode DIP Switch Values Procedure The AUTO mode allows the user to select one of 10 preset programs 0 to 9 for the COLORdash Accent UV or 12 preset auto programs 0 to 11 for the COLORdash Accent VW Select the AUTO program by setting DIP switches 1 through 4 as per the table below DIP Switch 1 2 3 4 Value 1 2 4 8 1 Set DIP switches 10 and 11 to OFF and DIP switch 12 to ON AUTO Mode 2 Select the desired program 0 to 11 by setting DIP switches 1 through 4 to ON or OFF until the sum of the value of the DIP switches in the ON position matches the desired program number 3 Refer to the examples below for more information a To select AUTO program 0 set DIP switches 1 through 5 to OFF and DIP switch 12
6. COLORdash Accent UV amp VW QRG COLORdash Accent UV DMX Channel Values SV 1 Channel Function Value Percent Setting 1 Dimmer 000 255 0 100 SV1 S Channel Function Value Percent Setting 1 Dimmer 000 255 0 100 2 Strobe 000 255 0 100 Contact Us General Information CHAUVET 5200 NW 108 Avenue Sunrise FL 33351 Voice 954 929 1115 Fax 954 929 5560 Toll free 800 762 1084 Technical Support Voice 954 929 1115 Press 4 World Wide Web COLORdash Accent UV amp VW QRG Rev Ole Copyright 2010 CHAUVET All rights reserved Printed in the P R C Fax 954 929 3716 www chauvetlighting com Page 8 of 8 COLORdash De card UV amp VW Quick Reference Guide PROFESSIONAL Co Mit l COLORdash Accent UV amp VW QRG About this Guide The COLORdash Accent UV amp VW Quick Reference Guide QRG only contains the connection and mounting information as well as the menu options and the DMX values for the COLORdash Accent UV and VW COLORdash Accent UV amp VW QRG Disclaimer This QRG does not replace the products user manuals You must download the corresponding user s manual from the CHAUVET Web site www chauvet com to learn about the disclaimers safety notes programming modes and technical information Fixture ata Glance What is Included UV Features VW Features Common Features Options
7. ith a COLOR CON controller instead of a master unit The DIP switches on the back of the unit have two configuration zones a fixed assignment zone for Operation Mode Selection DIP 10 12 and a variable assignment zone DIP 1 9 whose configuration changes depending on the operation mode selected as shown below DIP Switches 1 4 Color Intensity STATIC Mode active DIP Switches 1 4 AUTO Programs Selection AUTO Mode active DIP Switches 1 9 DMX Address Selection DMX Mode active DIP Switches 10 12 Operation Mode Selection See table below DIP 10 DIP 11 DIP 12 COLORdash Accent UV COLORdash Accent VW ON OFF OFF SLAVE COLOR CON SLAVE COLOR CON OFF OFF ON AUTO AUTO ON OFF ON STATIC STATIC OFF ON OFF SV 1 1 channel STD W 2 channels ON ON OFF SV1 S 2 channels S1 DS 5 channels OFF OFF OFF Reserved STD D 3 channels ON ON ON Reserved STD 1 2 channels OFF ON ON Reserved Reserved Starting Address Starting Address DIP Switch Values Procedure Examples for STD D When any of the four DMX modes is active as per the Operation Mode Table you can select the starting DMX address 1 512 by setting DIP switches 1 through 9 as per the table below DIP Switch 1 2 3 4 5 6 7 8 9 Value 1 2 4 8 16 32 64 128 256 1 To select any of the four DMX modes set DIP switches 10 11 and 12 as per the Operation

Download Pdf Manuals

image

Related Search

Related Contents

Hotwire thermo-anemometer VT110 - VT115  Table of Contents Introduction ........................................................  Manuale tecnico - Orsini & Belfatto  MobileView™ Tablet T750  TECNOFLEX  技術機関誌 SINEWS: VOL 56 No.1 (March 2013)  Samsung KNOX Training Enterprise Troubleshooting  Harbor Freight Tools 6.25 gal. Oil Extractor Product manual  Supermicro X7DBI+ motherboard  DeLOCK 2.5” enclosure > USB 2.0  

Copyright © All rights reserved.
Failed to retrieve file