SuperBus 2000 Energy Saver Module Installation
Contents
1. 2 Splice the wire from ESM Terminal 2 to the thermostat terminal where the red wire power was disconnected Connecting a Two wire Thermostat 1 On the thermostat disconnect a wire and reconnect it to ESM terminal 1 2 Connect a wire from ESM terminal 2 to the thermostat where the original wire was disconnected Setting a Module Unit Number Concord v2 0 later Concord 4 and Concord Express v4 Panels For Concord v2 0 later Concord 4 and Concord Express v4 panels unit numbers are automatically learned by the panel after the system receives power If using one module per partition the panel automatically assigns each module a partition number Concord v1 0 1 6 and UltraGard Panels A module can be set to any unit number 0 15 with the module s DIP switches If no other bus modules are installed in a system the default setting 0 can be used If using one module per partition the lower unit number is assigned to Partition 1 the higher unit number is assigned to Partition 2 Note Because unit numbers for Concord RF receivers are factory set to 15 do not use this unit number setting SuperBus 2000 Energy Saver Module Installation Instructions Setting DIP Switches On the module locate the DIP switches see Figure 1 Next set the desired unit number from 0 to 15 see Figure 6 before turning the power on Note Do not change DIP switch settings after the panel is powered e UltraGard UN
2. ESM to a Concord Panel 1 Remove panel AC power and disconnect the backup battery 2 Turn off the thermostat and remove cover 3 Route a four conductor 22 gauge or larger diameter stranded wire from the ESM to the panel 4 Connect terminals 3 6 to the panel see Figure 4 below Figure 4 ESM wiring connections to thermostat and Concord panel 12V BUS BUS Dc A B GND ESM Terminals To Furnace Thermostat Concord Panel 3 Terminals a5 3 GND 12V BUS BUS DC A B 5 Route a two conductor 22 gauge or larger diameter stranded wire from the ESM to the thermostat SuperBus 2000 Energy Saver Module Installation Instructions Wiring the ESM to an UltraGard Panel 1 Set the panel s power switch to OFF Next unplug the AC power transformer and disconnect the backup battery 2 Turn off the thermostat and remove cover 3 Route a four conductor 22 gauge or larger diameter stranded wire from the ESM to the panel 4 Connect terminals 3 6 to the panel see Figure 5 Figure 5 ESM wiring connections to thermostat and Ultragard panel DC BUS BUS Out A B GND ESM Terminals To Furnace Thermostat UltraGard Panel Terminals w d ks da DC BUS BUS GND Out A B 5 Route a two conductor 22 gauge or larger diameter stranded wire from the ESM to the thermostat Connecting a Four wire Thermostat 1 On the thermostat disconnect the red wire power and splice it to the wire connected to ESM Terminal 1
3. the ESM s room temperature setting Troubleshooting If your module does not function properly refer to Table 3 below for a list of troubleshooting solutions Table 3 Troubleshooting Problem Action Solution Bus LED remains 1 Check for proper wiring connections off 2 Ensure the panel s AC power transformer is plugged in and the backup battery is connected For UltraGard panels ensure the panel s power switch is set to ON 3 Verify the panel recognizes the ESM and is located in the correct partition 4 If the LED remains off replace the module Bus LED fails to flash Concord 1 Check for proper wiring connections 2 Ensure each bus device is set with different unit numbers v1 0 1 6 only 3 If the unit number DIP switches are changed disconnect and reconnect panel power v1 0 1 6 only Next enter the panel s Program Mode and delete the previously assigned ESM unit number see specific panel Installation Instructions for more information 4 If the LED fails to flash replace the module UltraGard 1 Set the Run Program switch to RUN and set the panel s power switch to OFF 2 Check for proper wiring connections 3 Ensure each bus device is set with different unit numbers 4 If the unit number DIP switches are changed turn the panel off and turn on again Next enter the panel s program mode and delete the previously assigned ESM unit number see specific panel nstallation Ins
4. IT NUMBER 0 7 e Concord UNIT NUMBER 0 15 Figure 6 ESM unit number DIP switch settings UNIT NUMBER 0 UNIT NUMBER 1 UNIT NUMBER 2 a i a I CBRBRBRR A Pegeeges Pagaggeg 12345 2345678 UNIT NUMBER 3 UNITNUMBER4 UNIT NUMBER 5 mon a PRRBRERE 12345678 M ion BEERRED a PRRREPRE 2345678 12345678 zog UNIT NUMBER 8 1 PBBBEBRRB 12345678 UNIT NUMBER 6 Begggeea a 12345678 gt z gt 5 Nop wie aa woo an Sia oD UNIT NUMBER 9 UNIT NUMBER 10 EQQQRQRE 12 67 8 345 UNIT NUMBER 11 Pegepgng i Seagegne 12345678 12345678 gt z gt z UNIT NUMBER 12 UNIT NUMBER 13 o M PREGEERE 12345678 UNIT NUMBER 14 r BRGQgese 2345678 gt z gt 5 Nea wam az oD o aa oo ED UNIT NUMBER 15 Do not use in Concord RF systems a gt PREREEER 12345678 gt Power Up and Bus Communication When powering the system or verifying bus communications refer to the following procedures For Concord Panels all versions Note To enter panel program mode and verify unit numbers an alphanumeric touchpad must be connected to the Concord panel Refer to the specific panel nstallation Instructions for more information 1 Verify all wiring at the panel and module is correct 2 Connect the panel s backup battery and plug in the AC power transformer 3 Verify that the ESM LED flashes If desired
5. enter panel program mode and verify that unit numbers exist and that the module is in the correct partition see panel Installation Instructions for more information Note If the ESM LED does not flash disconnect the panel s AC power transformer and backup battery If you continue to experience problems refer to Table 3 For UltraGard Panels 1 Verify all wiring at the panel and module is correct 2 Connect the panel s backup battery and plug in the AC power transformer 3 Set the panel s power switch to ON 4 Set the panel s Run Program switch to PROGRAM If the alphanumeric display reads 1 OFF and the 7 flashes you must enter an installer code to place the panel into program mode Refer to specific panel nstallation Instructions for more information The ESM LED continuously flashes to indicate successful panel communication Note If the ESM LED does not continuously flash set the Run Program switch to RUN Next set the panel s power switch to OFF and disconnect the AC power transformer and backup battery If you continue to experience problems refer to Table 3 Additional Information For information on operating programming testing and deleting an ESM please refer to specific panel Installation Instructions or User s Manual Note To ensure consistency between an ESM and home thermostat the ESM must be installed and powered for a minimum of 15 minutes For best results wait one hour to adjust
6. interlogix A UTC Fire amp Security Company SuperBus 2000 Energy Saver Module Installation Instructions Product Summary The SuperBus 2000 Energy Saver Module ESM monitors and controls temperatures By overriding an existing HVAC thermostat the ESM uses low and high temperature limits to save on energy use With the ESM on temperature limits determine when heating or air conditioning units are on When the ESM is off the HVAC thermostat controls heating and air conditioning units For example if the HVAC thermostat is set at 68 F and the ESM high limit is set to 80 F the ESM prevents the air conditioner from turning on until the temperature reaches 80 F ESM limits can be set from 40 F to 90 F If temperatures drop below a set freeze temperature default 42 F a temperature sensor monitors and reports a freeze alarm to the panel If the temperature drops to 45 F 6 F a backup freeze thermostat provides additional protection by activating the furnace Note Depending on the location of the ESM additional freeze sensors may be required to provide adequate freeze protection This device is compatible with Concord and UltraGard panels SuperBus 2000 vs SuperBus SuperBus 2000 panels auto address module unit numbers When the panel is powered a unique device ID number pre programmed at factory is automatically learned by the panel Potential identical unit number conflicts and the need to manual
7. ly set DIP switches are eliminated Older SuperBus panels can communicate with the ESM by manually setting the module s DIP switches SuperBus 2000 Panels Concord v2 0 later Concord 4 Concord Express v4 SuperBus Panels UltraGard Concord v1 0 1 6 Figure 1 ESM component locations SuperBus Device ID Backup Freeze Label Stat ESM Software Version Label Unit Number DIP Switches Temperature Sensor 4 le v e 000000 Terminal Strip Bus LED P N 466 1031 01 REV D 15FEB11 Table 1 ESM component descriptions ESM component Description Backup Freeze Thermostat Activates furnace when temperatures drop below 45 F 6 F SuperBus 2000 Device ID Identifies device ID numbers Number Label ESM Software Version Label Identifies installed software versions Panel and HVAC thermostat connections Terminal Strip Temperature Sensor Monitors temperature Bus LED Indicates panel bus communications Unit Number DIP Switches Used to manually set SuperBus unit numbers Installation Guidelines When installing the ESM consider the following guidelines For Concord and Concord Express v4 systems connect up to 16 bus devices to the panel alphanumeric touchpad HIM ESM For UltraGard systems connect up to eight bus devices to the panel e Assign each bus device a different unit number e For Concord system
8. o communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the affected equipment and the panel receiver to separate outlets on different branch circuits Consult the dealer or an experienced radio TV technician for help Contact information For contact information see www utcfireandsecurity com or www interlogix com For technical support toll free 888 437 3287 in the US including Alaska Hawaii Puerto Rico and Canada Outside the tool free area contact your dealer Copyright 2011 Interlogix a UTC Fire amp Security Company All rights reserved SuperBus 2000 Energy Saver Module Installation Instructions
9. r larger diameter stranded wire Installation Installation requires you to mount the ESM and wire the module to a panel and an existing HVAC thermostat Mounting the ESM 1 Press down on module cover and pull away from base see Figure 2 below Figure 2 Removing the module cover Press down here and pull away from base l Caution You must be free of static electricity while handling electronic components Touch a grounded bare metal surface before touching a circuit board 2 Place the ESM on the wall at the desired location and mark the upper left and lower mounting holes see Figure 3 below Figure 3 Module mounting hole locations Mounting Holes 3 Install anchors and secure the ESM to the wall Wiring While some thermostats control heating and cooling others control only heating A thermostat that controls both heating and cooling uses four wires a heat only thermostat typically has two Table 2 Four wire thermostat color codes Wire Function Red Power feed to thermostat Green Fan control Yellow Cooling White Heating Note If the thermostat wire colors differ from those described contact a qualified HVAC service person for specific thermostat wiring information Be sure to give the service person the thermostat s manufacturer name and model number Wiring the
10. s use one ESM for each partition for UltraGard systems the panel can accommodate one ESM e Maximum current draw for the ESM is 30 mA e When using panel power to supply bus or hardwired devices do not exceed the panel s total power output Refer to specific panel Installation Instructions for further detail e Use four conductor 22 gauge or larger diameter stranded wire to connect the ESM to the panel e Use two conductor 22 gauge or larger diameter stranded wire to connect the ESM to the thermostat e Install the ESM on an inside wall next to or as close as possible to the existing thermostat This helps maintain a minimal temperature difference between the ESM and the thermostat e When the ESM is turned on programmable thermostats that use batteries may lose their programmed settings Because the ESM relay can interrupt the thermostat s main power the thermostat may rely on battery power to maintain programmed settings As a result the thermostat s battery may need to be replaced more often depending how often and how long the ESM is turned on e Refer to the specific panel Installation Instructions for wire length limits Tools and Supplies Screwdrivers Phillips and slotted Screws and anchors included e Digital voltmeter e 3 8 drive drill and drill bits e Hammer e Wire cutters strippers e Four conductor 22 gauge or larger diameter stranded wire e Two conductor 22 gauge o
11. tructions for more information 5 If the module continues to fail replace the module Temperatures are 1 Check for proper wiring connections incorrect OR the 2 Verify the module is learned into the proper wrong furnace AC partition unit is under 3 Ensure the ESM is turned on control Specifications Compatibility Concord Concord 4 Concord Express v4 and UltraGard panels Power Requirements 12V DC 30 mA maximum from panel Storage Temperature 30 to 140 F 34 to 60 C Operating Temperature 32 to 140 F 0 to 60 C Dimensions 2 60 x 2 60 x 0 90 L x W x D Case Material ABS Plastic Installation Wall Mount Color Belgian Gray Regulatory information Manufacturer UTC Fire amp Security Americas Corporation Inc 1275 Red Fox Rd Arden Hills MN 55112 6943 USA FCC compliance FCC Part 15 Information to the User Changes or modifications not expressly approved by UTC Fire amp Security can void the user s authority to operate the equipment FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radi
Download Pdf Manuals
Related Search
Related Contents
Le manuel d`utilisation Comunicacao Beijer com CLPs Altus/Nap120 取扱説明書はこちら F=JーーRYGKー 取扱説明書 Model NTN7209A Charger Instruction Manual - Oppermann 取扱説明書 - Honda FUNAI ZV450TT8 Owner's Manual OM, Zenoah, NSB1510A, バッテリー噴霧機, 2012-06 T1 Fold (2KM) DN 100 RG/2MBZ RG/2MCS - Rólunk Copyright © All rights reserved.