1. Readout of the present value With the command ZUGR the access settings on the configuration menues with an activated password protection can be read out There are two possibilities the direct request on the access for the different menues or a general request for access settings Direct request on the access of a menu Host sends lt Address gt sr lt STX gt ZUGR P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P2 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Access levels GRUND gt Basic menu ESSP gt Measurement program RE gt Statistics reset KANAL gt Channel settings SV Measurement mode BEWER gt Evaluation SCHAL gt Switch points EINRI gt Teach in mode P2 Access for User 0 gt Access denied 1 gt Access allowed 31 BA_9310 Vxxx0_EN_2015 03 05 doc um General request for Access authorization Host sends lt Address gt sr lt STX gt ZUGR lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P4 P5 P6 P7 P8 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn
2. Parameter Meaning Wert P1 Access on menu General Settings 0 Access denied for User 1 gt Access allowed P2 Access on menu Measurement 0 gt Access denied program for User 1 gt Access allowed P3 Access on menu Statics Reset for 0 gt Access denied User 1 gt Access allowed P4 Access on menu Cannel Settings for 0 gt Access denied User 1 gt Access allowed P5 Access on menu Measurement 0 gt Access denied Mode for User 1 gt Access allowed P6 Access on menu Evaluation for User 0 gt Access denied 1 gt Access allowed P7 Access on menu Switch points for 0 gt Access denied User 1 gt Access allowed P8 Access on configuration mode for 0 gt Access denied User 1 gt Access allowed 32 BA_9310 Vxxx0_EN_2015 03 05 doc um 3 2 2 INFO 3 2 2 1 INFO Info line With the command INFO the info line of the device can be read out It contains the number of the software version the Serial number and the last date of adjustment Host sends lt Address gt sr lt STX gt INFO lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Info line e g V200101 SN123456 09 03 2001 3 2 2 2 STAN Station number Input of a new value With the command STAN
3. Parameter Meaning Value P1 Unit Y channel 0 gt user defined 19 N 2 gt kN 32 Nm 67 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 3 3 XPOT Channel setting X Potentiometer Input of a new value With the command XPOT the sensor channel X can be set to potentiometer This input is valid only in the present measurement program Host sends lt Address gt sr lt STX gt XPOT lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Readout of the present value With the command XPOT the present channel setting of X channel resp potentiometer can be read out Host sends lt Address gt sr lt STX gt XPOT lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Potentiometer yes or no 1 gt Potentiometer 0 gt no Potentiometer but standard signal 68 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 3 4 Input of a new value XNOR Channel setting X standard signal With the command XNOR the sensor channel X can be set to standard signal This input is valid only for the present measurement program Host sends DIGIFORCE answers Host sends Meaning of parameter Pn lt Address gt sr lt STX gt XNOR P1 lt ETX gt
4. DIGIFORCE answers lt STX gt dif2 dif 49 LF lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt The command KURY can be used to delete any data still in the output buffer if the KURY command has been interrupted Parameter P1 is optional no parameter means the curve will not be reduced prior to transfer Parameter 0 means the curve will not be reduced prior to transfer Parameter 1 means the curve is reduced prior to transfer corresponding to the reducing factor 1 to 20 which can be set using the MRED command Parameter 2 means the curve is transferred with minus optimization Parameter 3 means the curve is reduced and transferred with the minus optimization Example Reducing factor 4 means only every 4th value is transferred although the first and last values of the measurement curve are always transferred 148 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 4 2 Envelope 3 4 2 1 KXWE optimized transfer of the X values of the reference curve KXWE Transfer values from host to unit in an optimized manner With this command the X values normalized integer values only corrected by the zero point without taking into account the gradient of the reference curve can be transferred from the host to the unit in a time optimized manner The values are transferred in hexadecimal format without 0 termination to save time The first value is transferred as an absolute value all other va
5. Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Inverting Y channel 1 gt Inverting switched on 0 gt Inverting switched off 77 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 3 13 SKAX Scalar values X Input of a new value With the command SKAX the scalar values for the X channel can be transferred The entered values however are only taken over after a new calibration for this channel has been calculated DOKX DOKY This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt SKAX P1 P2 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 lower scalar value X channel Floating point number P2 upper scalar value X channel Floating point number Readout of the present value With the command SKAX the present scalar values can be read out Host sends lt Address gt sr lt STX gt SKAX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning
6. Valid range 2 to 4000 132 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 10 3 5 RSTA reference curve status Readout of present value With the RSTA command the different states of the reference curve can be queried Host sends lt Address gt sr lt STX gt RSTA lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P4 P5 P6 P7 P8 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Status of Y values of the reference curve for creating the envelope 0 gt no reference curve 1 gt values already retrieved 2 gt new values Status of X values of the reference curve 0 no reference curve 1 gt values already retrieved 2 gt new values P3 Status of Ymin values of the reference curve 0 gt no reference curve 1 gt values already retrieved 2 new values Status of Ymax values of the reference curve 0 no reference curve 1 gt values already retrieved 2 new values Status of Y values of the reference curve for creating the trend curve 0 gt no reference curve 1 gt values already retrieved 2 new values Status of Y cumulative values of the reference curve for creating the 0 gt no reference curve trend curve 1 gt values already retrieved 2 new values Reserved Reserved 133
7. lt Address gt sr lt STX gt MKLX P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Type of calibration value UNTEN gt Measure lower cal val OBEN gt Measure upper cal val 3 3 3 18 MKLY Measure calibration value Y channel With the command MKLY the calibration values for the Y channel can be measured It must be indicated which calibration value is to be measured The entered values however are only taken over after a new calibration for this channel has been calculated DOKX DOKY This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt MKLY P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Type of calibration value UNTEN gt Measure lower cal val OBEN Measure upper cal val 3 3 3 19 DOKX Execute calibration on X channel With the command DOKX a calculation of calibration data for the X channel is started Only then the calibration data is taken over During calculation the data is being checked If this check has a negative outcome the device sends a NAK and does not take over the calibration The command has no further parameters This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt DOKX lt ETX gt l
8. lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Testmode 1 gt Testmode on 0 gt Testmode off 165 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 7 2 BERX Setting of the X channel range This command is only vaild if the Test mode is active Input of a new value With the commmand BERX the X channel range can be set for test reason Host sends lt Address gt sr lt STX gt BERX P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 X channel range 0 gt 5V 1 gt 10V Readout of present value With the commmand BERX the current X channel range can be read out Host sends lt Address gt sr lt STX gt BERX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 X channel range 0 gt 5V 1 gt 10V 166 BA_9310 Vxxx0_EN_2015 03 05 doc 3 7 3 DMSY Setting of Y channel range DMS type This command is only vaild if the Test mode is active Input of a new value With the command DMSY the Y channel range can be set for test reason Host sen
9. End sign ETX 0x03 or ENQ 0x05 with fragmentation Block Check 1 Byte Checksum all Bytes after STX including ETX ENQ are XOR combined Example Host sends INFO command to DIGIFORCE 9310 Host sends lt STX gt 0 1 INFO lt ETX gt lt 179 gt DIGIFORCE 9310 answers lt 2 gt 0 1 0 0 V200606 298043 15 11 2006 lt 3 gt lt 242 gt BA_9310 Vxxx0_EN_2015 03 05 doc MR 2 4 General instructions 2 4 1 Interface watchdog timer 2 4 1 1 Timer A response timer Timer A is used by the DIGIFORCE 9310 to protect itself from an invalid response or no response e Start Timer A is started after data transfer has been terminated with lt ETX gt The instrument waits for an acknowledgement by the master e Stop Timer A is stopped if a valid response lt ACK gt has been received e Timeout If a timeout occurs the DIGIFORCE 9310 sends an lt EOT gt and returns to its initial state ready for a new command The timeout for Timer A is set to 5 seconds 2 4 1 2 Timer B receive timer Timer B is used by the receive station to protect itself against non recognition of the lt ETX gt character e Start Timer B is started after receiving the lt STX gt character e Restart Timer B is restarted as long as data is being received in order to allow variable data block lengths to be received e Stop Timer B is stopped when the ETX character has been received e Timeout If a timeout occurs the received data command is discarde
10. Generalinstructions cdf e e ae a a aa aaae ea araa e Aa a aE E Kae aeaa 22 2 4 1 Interface watchdog timer oeiee ra denen UT asian 22 2 4 1 1 Timer A response timer useiisiseieines e einsenden d ann deine 22 2 4 1 2 Timer B recelve timet 1d ended ee D eg e ciel ei n dit 22 2 4 2 Information about the command descriptions esssssssssseeeeeme 23 3 INTERFACE COMMANDOD eie eene ea ae a EORR eS 24 3 1 COMMAN GOMANGS ESL 24 3 1 1 Detault Calibrationz a neo oh Ee eme rere ient Reed e Ue Re RE Eee E Ree EROR RE 24 3 1 1 1 LGRK Load default calibration sssssssssssssee eee 24 3 1 2 Informationen for PC software DIGICONTROL sese eene 25 3 1 2 1 DIGI DIGICONTROL specific device properties ssssssssssssseee 25 3 1 2 2 IDEN Serial number and device information ssssssse 26 3 2 General Settings sisan riria AEE iE EEEE Rin tenerae niger YN E ERR RR ae RReEa gen 28 3 2 1 Access authorlZation oc om eee D RR Lee PO EE eed nee tide 28 3 2 1 1 MPAS Master paS SVOTA e a a a e e aara a Kaa aae a aa tentent 28 3 2 1 2 UPAS User password a e pr ee eee da 29 3 22123 PASP Activate password idee eddie d ee rd edat ede lds dei rade ha 30 3 2 1 4 ZUGRAcCceSS levels de en ceo edid stage vedo aee i RR ge ne dd RR dees 31 3 2 lassen E 33 Se2
11. Host sends lt Address gt sr lt STX gt MPAS lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Master password 0 9999 28 BA_9310 Vxxx0_EN_2015 03 05 doc um 3 2 1 2 UPAs User password Input of a new value With the command UPAS you can set a new user password Host sends lt Address gt sr lt STX gt UPAS P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 User password 0 9999 Readout the present value With the command UPAS you can read out the present user password Host sends lt Address gt sr lt STX gt UPAS lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 User password 0 9999 29 BA_9310 Vxxx0_EN_2015 03 05 doc MR 3 2 1 3 PASP Activate password Input of a new value With the command PASP the password protection can be activated deactivated Host sends lt Address gt sr lt STX gt PASP P1 lt E
12. P4 P5 P7 10 Bit3 reserved 26 BA_9310 Vxxx0_EN_2015 03 05 doc Mun Bit4 reserved Bit5 reserved Bit6 reserved Bit7 reserved Identifier of specific software version BitO0 Channel settings locked third Byte Bit1 Measuring mode locked Bit2 Sendor test locked Bit3 Evaluation locked Bit4 Switch points locked Bit5 Display locked Bit6 Envelope locked Bit7 reserved hex unsigned short Identifier of specific software version BitO reserved fourth Byte Bit1 reserved Bit2 reserved Bit3 reserved Bit4 reserved Bit5 reserved Bit6 reserved Bit7 reserved hex unsigned short IP 1 access restriction 0 gt access not possible 1 gt access possible Host IP address 1 Long 32 Bit HEXFORMAT IP 2 access restriction Host IP address 2 IP 3 access restriction 0 gt access not possible 1 gt access possible P23 Host IP address 3 Long 32 Bit HEXFORMAT 27 BA_9310 Vxxx0_EN_2015 03 05 doc 3 2 General settings 3 2 1 Access authorization 3 2 1 1 MPAS Master password Input of a new value With the command MPAS ia new master password can be set Host sends DIGIFORCE answers Host sends Meaning of parameter Pn lt Address gt sr lt STX gt MPAS P1 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Parameter Meaning Value P1 Master password 0 9999 Readout of the present value With the command MPAS the present master password can be read out
13. The last block of 40 is padded with dummies There may be up to 4000 values Thus there may be up to 100 blocks The host must previously have retrieved the number of values using the RANZ command Host sends lt Address gt sr lt STX gt R YMA lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P40 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt STX gt P41 P42 P43 P80 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter P1 P4000 Delta Y maximum values of the reference Hex values without 0 curve termination 138 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 10 3 11 RYTR Y mean values of the reference curve non tracked values If trend is activated this relates to the non tracked values RYTR Values from host to unit With this command the Y mean values normalized value values corrected by the zero point of the reference curve can be transferred from the host to the unit The Y mean values are transferred in blocks of up to 20 values parameters 2 to 21 Parameter 1 is the block number With a maximum of 4000 values there is thus a maximum of 200 blocks The block number therefore gives the number of blocks which each contain 20 values Full 20 value containing blocks must always be transferred However the unit only cons
14. dull 3 3 1 Co Co Oo Ne Co 9 Q9 O0 CQ Q0 Q9 C0 0 Q0 Q0 Q0 Q0 C0 O9 t0 O o 00 00 0 ww C WWW CO CO w Uw w w C0 CO CO CO WWWWW Qo C0 WW WW CO CO WWW CO Ww ji v2 PPR RP FP 2 THO Of 8 PRNR Program numb6r ei cet ebrei ca e ee pet t ane ber ee i s PRAW Program name ime toni v nr nde e DRE sad ORE I te EXE toed ei eee NAME Program name on each measurement program sseeeee BDEX User defined unit X channel sssssessseeeeeenm nennen BDEY User defined unit Y channel esses emen AUSC Switch on off of Auto Scaling esseeeeene enne SCAL Manual Scaling of Measurement curve ssssssssee eee NIOA NOk display in percent absolute sssssssssssseeeeeeneees Measurement menu release cisssssssssseeee eene ehe nnhenn nr eresnn tens d nasi seda d sa sanas ddl ne d MFRE Measurement Menus sessi nnn rana nana Connection of Sensors ee e eo od te e ee ee DUE dns zI YA OF WN 10 11 12 413 RINGAN A ntt mutant nmn mt EXINYc pl Y essei a iei doe bdo XPOT Channel setting X Potentiometer ssssssee eem XNOR Channel setting X standard signal ssssssseee en YNOR Channel setting Y standard signal sssssseseeeee YDMS Channel setting Y strain gage emen YPIE Set the range for Pie
15. lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P20 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt STX gt P21 P22 P23 P40 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 P4000 Y difference values of the reference Hex values without 0 curve termination 152 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 4 2 3 KYSU optimized transfer of the Y cumulative values of the reference curve KYSU Transfer values from host to unit in an optimized manner With this command the Y cumulative values normalized value values corrected by the zero point without taking into account the gradient of the reference curve can be transferred from the host to the unit The values are transferred in hexadecimal format without 0 termination to save time The first value is transferred as an absolute value all other values are transferred as a difference from the preceding value The difference values are transferred in blocks of up to 20 values parameters 2 to 21 Parameter 1 is the block number With a maximum of 4000 values there is thus a maximum of 200 blocks The block number therefore gives the number of blocks which each contain 20 values Full 20 value containing blocks must always be transferred However the unit only considers values up until the number of values has been reached In the last block any of the 20 values which rem
16. lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Standard signal yes or no 1 gt Standard signal 0 gt not a standard signal but potentiometer 70 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 3 6 YDMS Channel setting Y strain gage Input of a new value With the command YDMS the sensor channel Y can be set to strain gage input This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt YDMS P1 P2 P3 P4 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn P1 Input terminal voltage 2 5V gt 2 5V input voltage 5V 5V input voltage P2 Sensitivity in mV V Positive Floating point numbers e g 1 498 P3 End value of sensor Floating point numbers e g 150 0 P4 Used range of sensor how great are Floating point numbers e g 125 0 the maximum sensor forces that occur in the given application Readout of present value With the command YDMS the present channel setting for channel Y resp strain gage signal can be read out Host sends lt Address gt sr lt STX gt YDMS lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Ad
17. measurement function depending on displacement or time As a result of this difference the value limits for the parameters change and in case these limits are passed the device answers with NAK This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt RAST P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn for measurement function Y F X Parameter Meaning Value P1 Sampling rate 0 001 1000 0 for measurement function Y F XT oder Y F T Parameter Meaning Value P1 Sampling grid ms 0 2 500 0 Readout of the present value With the command RAST the present value of the sampling raster can be read out Host sends lt Address gt sr lt STX gt RAST lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Sampling grid Floating point numbers with unit e g 1 23ms 92 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 6 3 BZUG Reference Input of a new value With the command BZUG the curve reference can be selected This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt
18. 05 doc lian 3 3 7 2 SCHB Switch point 2 Input of a new value With the command SCHB the second Online switch point can be defined In case of Absolute reference or Block reference of the measurement curve the switch point refers to the absolute zero point with an active Trigger reference it refers to the trigger value This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt SCHB P1 P2 P3 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Channel X gt X channel Y gt Y channel P2 Switch point value Floating point number without unit P3 Reference ABS gt Reference Absolute TRIG gt Reference Trigger Only channel X and if Trigger is active Readout of present value With the command SCHB the settings for the second switch point can be read out Host sends lt Address gt sr lt STX gt SCHB lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Channel X gt X channel Y gt Y channel P2 Switch point value Floating point number without unit P3 Reference ABS gt Reference Absol
19. 148 3 4 2 Envelope recedente rae ee Dept od HERR ER THEN PER AER de EUER EPA NERA R ae Paes anne 149 3 4 2 1 KXWE_ optimized transfer of the X values of the reference curve 149 3 4 2 2 KYWE optimized transfer of the Y mean values of the reference curve tracked values 151 3 4 2 3 KYSU optimized transfer of the Y cumulative values of the reference curve 153 3 4 2 4 KYTR optimized transfer of the Y mean value values of the reference curve non tracked values sc et o ecu ee ted eedem uae cu P R 155 BA_9310 Vxxx0_EN_2015 03 05 doc an 3 4 2 5 KYMI optimized transfer of the delta Y minimum values of the reference curve 157 3 4 2 6 KYMA optimized transfer of the delta Y maximum values of the reference curve 159 3 5 9310 V2xxx specific commands Black box module eene 161 3 5 1 TRAX Transmitter supply X channel sss eene 161 3 5 2 TRAY Transmitter supply Y channel sss eee 162 OL EMECUIEJ OCC 163 346b ESTA Error Status eee eT fe e ti eb e fe RE Pe ea s 163 3 6 2 ERRO Read out of device error status sssssssssseeen enm 164 3 Testmode coeno ng eee nee et E FREI REEF EKA EN KARTENN 165 3 7 1 TEST Testmode Or Off ote ere er redit e AAE neenon de ea Poe ER REA EE n tease 165 3 7 2 BERX Setting of the X channel range ssssssesssseeeeen menm 166 3 7 3 DMSY Setting of Y channe
20. BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 10 3 6 RYWE Y mean values of the reference curve tracked values If trend is activated this relates to the tracked values RYWE Values from host to unit With this command the Y mean values normalized values values corrected by the zero point of the reference curve can be transferred from the host to the unit The Y mean values are transferred in blocks of up to 20 values parameters 2 to 21 Parameter 1 is the block number With a maximum of 4000 values there is thus a maximum of 200 blocks The block number therefore gives the number of blocks which each contain 20 values Full 20 value containing blocks must always be transferred However the unit only considers values up until the number of values has been reached In the last block any of the 20 values which remain unfilled can be padded with dummies The number of values must therefore be transferred prior to this command using the command RANZ Host sends lt Address gt sr lt STX gt RYWE P1 P2 P21 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Meaning Block number Integer value 1 to 200 P2 P21 Y mean values of the reference Hex values without 0 curve termination RYWE Values from unit to host With this command the Y mean values normalized values values corrected by the zero point of the reference curve can be transferred from the unit to the host 40
21. BZUG P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Curve reference ABS gt Absolute reference TRI gt Trigger reference END gt Block reference BLF Block window Readout of the present value With the command RDYM the present curve reference can be read out Host sends lt Address gt sr lt STX gt BZUG lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Curve reference ABS gt Absolute reference TRI gt Trigger reference END gt Block reference BLF Block window 93 BA_9310 Vxxx0_EN_2015 03 05 doc ian 3 3 6 4 TRGP Trigger point Input of a new value With the command TRGP the trigger point can be entered This command makes sense only if the trigger reference has been chosen If this is not the case then the entered value has no effect This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt TRGP P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 trigger point Floating p
22. Bit HEXFORMAT 40 BA_9310 Vxxx0_EN_2015 03 05 doc um 3 2 6 6 BUID 9310 device identifiers Readout of the present value With the command BUID Device specific identifiers can be read out Host sends lt Address gt sr lt STX gt BUID lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 P16 P17 P18 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn ASCII String 9310 P1 Devi P2 Serial number ASCIIStrng P3 Devicename ASCIIString P1 P2 P3 P4 Status if the device is reserved from a host 0 gt device not reserved pem Address IP Address of the host long 32Bit HEXFORMAT P5 P6 Counter on software changes of the On every change of the Ethernet modul software this Ethernet modul value is incremented The value start at version V200604 with 0 unsigned short MAC address P7 Long 32 Bit HEXFORMAT Gateway address i Version of the sensor hardware BitO 0 DMS standard Bito 1 Piezo hex unsigned short P13 Version of the communikation hardware 0x0 standard RS232 485 BitO 1 PROFIBUS available Bit1 0 RS485 Bit1 1 Ethernet Bit2 0 display device Bit2 1 Blackbox unsigned short Counter an software changes with influence On every change of the 9310 software with influence
23. Characters REM STX Start of text 0x02 STX CHRS 2 REM ETX End of text 0x03 ETX CHR 3 REM EOT End of transmission 0x04 EOT CHR 4 REM ENQ Enquiry 0x05 ENQS CHR 5 REM ACK Acknowledge 0x06 ACKS CHR 6 REM LF line feed 0x0a LFS CHR 10 REM CR carriage return 0Ox0d RES CHR 13 EM NAK not acknowledge 0x15 REM FALHEEEEEEEEE AEE EEE EEE EEEE EEE EEE EEE EEE EEE FEE EEE PEE PEE PE ET REM Dialog Selection and opening initialisation of PC Interface REM EEEEEEELE ELEAF EEE EE EEE E EEE CLS INPUT Which interface do you want to use 1 gt COM1 2 gt COM2 a F a lt gt 1 AND a lt gt 2 THEN PRINT illegal Interface END F a 1 THEN com COMI F a 2 THEN com COM2 openstr com 9600 N 8 1 PRINT REM rs232 initialisation OPEN openstr FOR RANDOM AS 43 REM FEEEHEEEEE HELE ELEAF EEE EEF EEE EEEE EEE EEE EEE EEF EEE EEE HEE PH ET REM Ask Device adr 0 for ID String with Mode selection with response REM one of the two communication modes REM 4 HET TETTE REEEBERYA B BA SRM B 4 PH ET PRINT gt gt gt gt gt Connecting Device with adress 1 REM Sending selection supervisory sequence and pick up answer send EOT first to end other probably unanswered enquiries PRINT 3 EOTS 00 sr ENQS REM clear answer string ants mn REM read characters from serial interface ant IN
24. Meaning of parameter Pn Parameter Meaning Value P1 Window display in the envelopes setup 0 gt windows are not displayed menu 1 gt windows are displayed Readout of present value With the AEHF command it can be queried whether window display in the envelopes setup menu is switched on or off Host sends lt Address gt sr lt STX gt AEHF lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 Window display in the envelopes setup 0 gt windows are not displayed menu 1 gt windows are displayed 142 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 10 4 3 AEHK display selection in the window setup menu Input of a new value With the AEFK command the display selection when setting up the window can be set If trend is not activated then display of the trend limits is not possible If envelope is not active then display of reference curve and trend limits is not possible Current curve reference curve trend limits Host sends lt Address gt sr lt STX gt AEFK P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn P1 What is displayed in the window setup menu MESS gt display of the current measurement curve REF gt display of the reference
25. P1 lt ETX gt lt BCC gt lt ACK gt lt EOT gt meaning value P1 Software version Ethernet modul String 38 BA_9310 Vxxx0_EN_2015 03 05 doc 3 2 6 4 COMM coded uncoded Ethernet communication Input of a new value With the command COMM the UDP communication is set coded or uncoded Host sends lt Address gt sr lt STX gt COMM P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn P1 Code style of UDP communication 0 gt only coded 1 coded and uncoded Readout of the present value With the command COMM the UDP communication style coded or coded and uncoded can be read Host sends lt Address gt sr lt STX gt COMM lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter meaning value P1 Code style of UDP communication 0 gt only coded 1 gt coded and uncoded 39 BA_9310 Vxxx0_EN_2015 03 05 doc 3 2 6 5 Input of a new value HOST Host IP addresses access restriction With the command HOST It is possible to set up to three Host IP addresses which are only allowed to communicate with the DIGIFORCE 9310 Ift he restriction of all addresses is set to 0 access not possible there is
26. Value P1 lower scalar value X channel Floating point number P2 upper scalar value X channel Floating point number 78 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 3 14 SKAY Scalar value Y Input of a new value With the command SK AY the scalar values for the Y channel can be transferred The entered values however are only taken over after a new calibration for this channel has been calculated DOKX DOKY This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt SKAY P1 P2 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 lower scalar value Y channel Floating point number P2 upper scalar value Y channel Floating point number Readout of the present value With the command SKAY the present scalar values for the Y channel can be read out Host sends lt Address gt sr lt STX gt SKAY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 lower scalar value Y channel Floating point number P2 upper scalar value Y channel Floating point number 79 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 3 15 KALX Calibration val
27. a station number is transferred and saved for identifying the instrument in the interface mode Host sends lt Address gt sr lt STX gt STAN P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Station number Figure chain with length 10 e g 1234567890 Readout of present value With the command STAN the station number of the instrument can be read out Host sends lt Address gt sr lt STX gt STAN lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Station number Figure chain with length 10 e g 1234567890 33 BA_9310 Vxxx0_EN_2015 03 05 doc 3 2 3 LCD contrast 3 2 3 1 LCDK LCD contrast Input of a new value With the command LCDK a new value for the LCD contrast can be set Host sends DIGIFORCE answers Host sends Meaning of parameter Pn Parameter lt Address gt sr lt STX gt LCDK P1 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Meaning Value P1 LCD contrast Number from 0 min to 10 max Readout of present value With the command LCDK the present value of the LCD contrast can be read out Host se
28. and backup The P100 version supports an additional automatized data recording 2 1 Serial communication during measurement access During measurement of the DIGIFORCE 9310 there is no communication possible The device does not answer to a commad 2 2 Interface parameter of the serial RS232 485 interface The settings have to be defines in the general settings menue Baudrate 300 600 1200 2400 4800 96000 19200 38400 56000 57600 Data bits 7 or g Stop bits 4 or 2 Parity no even odd Blockcheck OFF ON no hardware handshake gt default setting after initialisation BA_9310 Vxxx0_EN_2015 03 05 doc an 23 Communication protocol Kontrollzeichen lt STX gt 0x02 gt start of Text lt ETX gt 0x03 gt end of Text lt ENQ gt 0x05 gt anquiry lt ACK gt 0x06 gt acknowlege S 0x20 gt space lt NAK gt 0x15 gt not Acknowlege lt LF gt Ox0A gt line feed lt EOT gt 0x04 gt end of transmission lt NUL gt 0x00 gt NUL sign ANSII standard X3 28 1976 Subcategory 2 5 A4 is used as the communications protocol This standard is used in systems in which a number of secondary stations exist in a non switched multipoint connection and all commands are sent by a control station Only one transmitter master and one receiver slave are ever active on the bus at one time One station is the control station The control station is given master status and sends commands to a selected slave stat
29. and trend switched on Host sends lt Address gt sr lt STX gt TNIO lt ET X gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 X coordinate of the point where the trend limit has Floating point number been crossed with X unit P2 Y coordinate of the point where the trend limit has Floating point number been crossed with Y unit 121 BA_9310 Vxxx0_EN_2015 03 05 doc Ww 3 3 10 2 Configuration of the envelope 3 3 10 2 1 HKRV Envelope switch ON OFF Input of a new value With the HKRV command the envelope can be switched on or off Host sends lt Address gt sr lt STX gt HKRV P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn P1 Switch envelope on off 0 gt Envelope is switched off 1 Envelope is switched on Readout of present value With the HKRV command it can be queried whether envelope is switched on or off Host sends lt Address gt sr lt STX gt HKRV lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 Switch envelope on of
30. can be used to delete any data still in the output buffer if the KURX command has been interrupted Parameter P1 is optional no parameter means the curve will not be reduced prior to transfer Parameter 0 means the curve will not be reduced prior to transfer Parameter 1 means the curve is reduced prior to transfer corresponding to the reducing factor 1 to 20 which can be set using the MRED command Parameter 2 means the curve is transferred with minus optimization Parameter 3 means the curve is reduced and transferred with the minus optimization Example Reducing factor 4 means only every 4th value is transferred although the first and last values of the measurement curve are always transferred 147 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 4 1 3 KURY optimized transfer of the Y values of the measurement curve With the KURY command the Y values of the measurement curve can be read in a time optimized manner The measurements are transferred in hexadecimal format without 0 termination to save time The first value is transferred as an absolute value all other values are transferred as a difference from the preceding value If more that two sequential difference values are the same then these are no transferred individually but rather in the following form M lt factor gt lt difference value gt M is the marker that indicates that this is not a single difference value It is followed by a factor that indicates the num
31. evaluation MESS5 gt Menu 5 General curve data P2 Display 0 gt do not show menu 1 gt show menu 64 BA_9310 Vxxx0_EN_2015 03 05 doc General request for menu release Host sends DIGIFORCE answers Host sends Host sends DIGIFORCE answers Host sends DIGIFORCE answers Meaning of parameter Pn lt Address gt sr lt STX gt MFRE lt ETX gt lt BCC gt lt ACK gt lt EOT gt lt Address gt po lt ENQ gt lt STX gt P1 P2 P3 P4 P5 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Parameter Meaning Wert P1 Display Measurement menu 1 0 gt do not show menu 1 gt show menu P2 Display Measurement menu 2 0 gt do not show menu 1 gt show menu P3 Display Measurement menu 3 0 do not show menu 1 gt show menu P4 Display Measurement menu 4 0 gt do not show menu 1 gt show menu P5 Display Measurement menu 5 0 gt do not show menu 1 show menu 65 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 3 Connection of sensors 3 3 3 1 Input of a new value EINX Unit X With the command EINX the unit for Measurement channel X can be entered This setting is valid only for the present measurement program Host sends DIGIFORCE answers Host sends Meaning of parameter Pn lt Address gt sr lt STX gt EINX P1 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Parameter Meaning Value P1 Unit X channel 0 gt user defined 12 mm 2
32. g the default address the Digicontrol 9310 softwaree uses the device serial number Host sends lt Address gt sr lt STX gt IDEN lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 P16 P17 P18 P19 P20 P21 P22 P23 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn 9310 Device options Bito 0 DMS standard BitO 1 Piezo Bit1 0 Anzeigegerat Bit1 1 Blackbox Pi pz P3 P4 P5 9310 device communication interfaces 0x0 Standard RS232 485 BitO 1 PROFIBUS available Bit1 0 RS485 Bit1 1 Ethernet hex unsigned short Counter an software changes with influence on serial On every change of the 9310 software communication with influence on serial communication this value is incremented The value starts on version V200208 with 0 decimally unsigned short Identifier of specific software version BitO 0 standard 1 specific software first Byte Bit1 PC software totally locked Bit2 reserved Bit3 reserved Bit4 Upload locked Bit5 Download locked Bit6 reserved Bit7 Laboratory operation mode locked hex unsigned short P Identifier of specific software version Bit0 General settings locked second Byte Bit1 Access authorization locked Bit2 Program access locked P1 P2 P3
33. gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Measurement display curve Meas display single window evaluation Meas display NOK statistics of windows Meas display total result Meas display general curve data 53 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 2 14 LCD update 3 2 14 4 UPDA Control LCD update Input of a new value With the command UPDA the LCD update can be switched on and off After power up of the device the update is switched on automatically Host sends lt Address gt sr lt STX gt UPDA P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 LCD update 1 gt Switch on update 0 gt Switch off update Readout of the present value With the command UPDA the present status of LCD update can be read out Host sends lt Address gt sr lt STX gt UPDA lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 LCD update 1 gt Switch on update 0 Switch off update 54 BA_9310 Vxxx0_EN_2015 03 05 doc 3 2 15 Burster Logo activation 3 2 15 1 Input of a new value LOGO Burster Logo With the command LOG
34. gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 User defined unit X channel Character chain of max 4 figures Readout of present value With the command BDEX the user defined unit of the X channel can be read out Host sends lt Address gt sr lt STX gt BDEX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 User defined unit X channel Character chain of max 4 figures 59 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 1 5 BDEY User defined unit Y channel Input of a new value With the command BDEY a string as user defined unit for Measurement channel Y can be configured This input is valid only for the present Measurement program Host sends lt Address gt sr lt STX gt BDEY P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 User defined unit Y channel Character chain of max 4 figures Readout of the present value With the command BDEY the user defined unit of the Y channel can be read out Host sends lt Address gt sr lt STX gt BDEY lt ETX gt lt BCC gt DIGIFOR
35. gt AEHK P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn P1 What is displayed in the envelopes setup menu MESS gt display of the current measurement curve REF gt display of the reference curve TREND gt display of the trend curve with reference curve Readout of present value With the AEHK command the display selection when setting up the envelope can be queried Current curve reference curve trend curve Host sends lt Address gt sr lt STX gt AEHK lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 What is displayed in the envelopes setup menu MESS gt display of the current measurement curve REF gt display of the reference curve TREND gt display of the trend curve with reference curve 141 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 10 4 2 AEHF switch on off window display in the envelopes setup menu Input of a new value With the AEHF command window display in the envelopes setup menu can be switched on or off If trend curve is switched on then window display cannot be switched on Host sends lt Address gt sr lt STX gt AEHF P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt
36. gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Bedeutung P1 Zero signal channel Y Float value 84 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 5 Sensor test 3 3 5 1 SETX Teach in sensor test X Input of a new value With the command SETX the value for the X channel is measured which later on functions as a reference value for the sensor test X During the sensor test this value must be met within the indicated tolerances This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt SETX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Readout of the present value With the command SETX the presently measured sensor test value for X channel can be read out Host sends lt Address gt sr lt STX gt SETX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Value for sensor test X Floating point number with unit e g 11 2345mm 85 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 5 2 SETY Teach in sensor test Y Input of a new value With the command SETY the value for the Y channel is measured which later on functions as a reference value f
37. in their respective units Floating point value Normalized absolute value gradient Host sends lt Address gt sr lt STX gt K X WE lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P2 0 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt STX gt P21 P22 P23 P40 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 P4000 Normalized X difference values Hex values without 0 of the reference curve termination 150 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 4 2 2 KYWE optimized transfer of the Y mean values of the reference curve tracked values If trend is activated this relates to the tracked values KYWE Transfer values from host to unit in an optimized manner With this command the Y mean values normalized integer values values corrected by the zero point without taking into account the gradient of the reference curve can be transferred from the host to the unit The values are transferred in hexadecimal format without 0 termination to save time The first value is transferred as an absolute value all other values are transferred as a difference from the preceding value The difference values are transferred in blocks of up to 20 values parameters 2 to 21 Parameter 1 is the block number With a maximum of 4000 values ther
38. of parameter Pn Parameter Meaning Value P1 Activation of measurement menu AUTO gt 9310 goes into measurement mode if the AUTO bit is during Proifibus access set STD 9310 goes into measurement mode as soon as Profibus access is active Readout of the present value With the command PMEM the status how the 9310 goes into measurement mode during Profibus access can be read out Host sends lt Address gt sr lt STX gt PMEM lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 Activation of measurement menu AUTO gt 9310 goes into measurement mode if the AUTO bit is during Proifibus access set STD gt 9310 goes into measurement mode as soon as Profibus access is active 47 BA_9310 Vxxx0_EN_2015 03 05 doc 3 2 8 Reset 3 2 8 1 RSET Start Reset With the command RSET the Statistics Reset can be started Host sends lt Address gt sr lt STX gt RSET lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt 48 BA_9310 Vxxx0_EN_2015 03 05 doc um 3 2 9 Block Measurement 3 2 9 1 MEFR Block Measurement Input of a new value With the command MEFR the start of a new measurement can be blocked Host sends lt Address gt sr lt STX gt MEFR P1 lt ETX gt lt BCC gt DI
39. on serial communication on serial communication this value is incremented The value starts on version V200208 with O Identifier of specific software version BitO 0 standard 1 specific software first Byte Bit1 PC software totally locked Bit2 reserved Bit3 reserved Bit4 Upload locked Bit5 Download locked Bit6 reserved Bit7 Laboratory operation mode locked hex unsigned short Identifier of specific software version BitO0 General settings locked second Byte Bit1 Access authorization locked Bit2 Program access locked Bit3 reserved Bit4 reserved Bit5 reserved 41 BA_9310 Vxxx0_EN_2015 03 05 doc burster Bit6 reserved Bit7 reserved hex unsigned short Identifier of specific software version BitO0 Channel settings locked third Byte Bit1 Measuring mode locked Bit2 Sendor test locked Bit3 Evaluation locked Bit4 Switch points locked Bit5 Display locked Bit6 Envelope locked Bit7 reserved hex unsigned short Identifier of specific software version BitO reserved fourth Byte Bit1 reserved Bit2 reserved Bit3 reserved Bit4 reserved Bit5 reserved Bit6 reserved Bit7 reserved hex unsigned short 42 BA_9310 Vxxx0_EN_2015 03 05 doc hen 3 2 6 7 MAST Ethernet host can reserve a DIGIFORCE 9310 This command can also used durin a running measurement Input of a new value With the command MUST The Ethernet host can temporary reserve an DIGIFORCE 9310 to block communicatin
40. range 1 to 99 i Readout of present value With the HARE command the number of reference curves used when setting up the envelope can be queried Host sends lt Address gt sr lt STX gt HARE lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Number of reference curves when setting up the envelope Valid range 1 to 99 131 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 10 3 4 RANZ number or reference curve points Input of a new value With the RANZ command the number of reference curve points can be set Host sends lt Address gt sr lt STX gt RANZ P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn P1 Number of reference curve points Valid range 1 to 4000 1 means no reference curve Readout of present value With the RANZ command the number of reference curve points can be queried Host sends lt Address gt sr lt STX gt RANZ lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value Number of reference curve points
41. sends lt EOT gt Meaning of parameter Pn lt Address gt sr lt STX gt DEFP P1 lt ETX gt lt BCC gt Parameter Meaning Value P1 Program number 0 7 3 2 11 3 CMPR Copy a Measurement program With the command CMPR a single Measurement program source program number can be copied to a group of Measurement program memory cells limited by TARGET START program number and TARGET END program number The necessary condition is that the TARGET END program number is greater or equal to the TARGET START program number Host sends DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn lt Address gt sr lt STX gt CMPR P1 P2 P3 lt ETX gt lt BCC gt Parameter Meaning Value P1 Source program number 0 7 P2 Target START program number 0 Target END program number P3 Target END program number Target START program number 7 51 BA_9310 Vxxx0_EN_2015 03 05 doc um 3 2 12 OK NOK graphical display 3 2 12 4 rNGR Selection OK NOK graphical display Input of a new value With the command INGR the symbol for display of an OK or NOK measurement in the relative Measurement menu can be chosen Host sends lt Address gt sr lt STX gt INGR P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Choose the graphical TEXT gt display OK NO
42. short P4 Identifier of specific software version BitO 0 standard 1 specific first Byte software Bit1 PC software totally locked Bit2 reserved Bit3 reserved Bit4 Upload locked Bit5 Download locked Bit6 reserved Bit7 Laboratory operation mode locked hex unsigned short P5 Identifier of specific software version BitO General settings locked second Byte Bit1 Access authorization locked Bit2 Program access locked Bit3 reserved Bit4 reserved Bit5 reserved Bit6 reserved Bit7 reserved hex unsigned short P6 Identifier of specific software version Bit0 Channel settings locked third Byte Bit1 Measuring mode locked Bit2 Sendor test locked Bit3 Evaluation locked Bit4 Switch points locked Bit5 Darstellung gesperrt Bit6 Envelope locked Bit7 reserved hex unsigned short 25 BA_9310 Vxxx0_EN_2015 03 05 doc um P7 Identifier of specific software version Bit0 reserved fourth Byte Bit1 reserved Bit2 reserved Bit3 reserved Bit4 reserved Bit5 reserved Bit6 reserved Bit7 reserved hex unsigned short 3 1 2 2 IDEN Serial number and device information Readout of the present value With the command IDEN device specific settings and informations can be read out The PC software Digicontrol 9310 use this command while searching 9310 devices on Ethernet network To differentiate several devices with the same IP address e
43. the command PBIN it can be determined if the control signals are read in via the PLC inputs or the PROFIBUS inputs Host sends lt Adress gt sr lt STX gt PBIN P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Source of control signals SPS 2 use PLC input signals PRO gt use PROFIBUS signals Readout of the present value With the command PBIN the present source of control signals can be read out Host sends lt Address gt sr lt STX gt PBIN lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Source of control signals SPS gt use PLC input signals PRO 2 use PROFIBUS signals 46 BA_9310 Vxxx0_EN_2015 03 05 doc MR 3 2 7 4 PMEM Einstellen der Messmen Anwahl bei Profibusverkehr The command PMEM is only active if the Pfofibus hardware is available device option Otherwise DIGIFORCE answers with NAK Input of a new value With the command PMEM can be specified how the 9310 goes into measurement mode during Profibus access Host sends lt Address gt sr lt STX gt PMEM P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning
44. values are always transferred at the same time After polling these first 40 values are transferred Once the host has confirmed receipt with lt ACK gt the next 40 values are transferred This continues until all values have been transferred When all values have been transferred the unit answers with lt EOT gt following the lt ACK gt Full 40 value containing blocks are always transferred The last block of 40 is padded with dummies There may be up to 4000 values Thus there may be up to 100 blocks The host must previously have retrieved the number of values using the RANZ command Host sends lt Address gt sr lt ST X gt R Y WE lt ET X gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P40 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt STX gt P41 P42 P43 P80 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 P4000 Y mean values of the reference Hex values without 0 curve termination 134 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 10 3 7 RYSU Y cumulative values of the reference curve RYSU Values from host to unit With this command the Y cumulative values normalized values values corrected by the zero point of the reference curve can be transferred from the host to the unit The Y cumulative values are transferred in bl
45. values using the RANZ command The host must calculate the absolute values from the difference values with the exception of the 1st value Absolute value n absolute value n 1 difference value n The transferred difference values and the absolute values calculated from them are normalized integer values 16 bit These values are used with the gradient values which are retrieved using the KRVA command to calculate the floating point values in their respective units Floating point value Normalized absolute value gradient Host sends lt Address gt sr lt STX gt K Y MI lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P20 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt STX gt P21 P22 P23 P40 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 P4000 Difference values of the delta Y minimum values of the Hex values without 0 reference curve termination 158 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 4 2 6 KYMA optimized transfer of the delta Y maximum values of the reference curve KYMA Transfer values from host to unit in an optimized manner With this command the delta Y maximum values normalized integer values values corrected by the zero point without taking into account the gradient of the reference curve can be
46. with unit for block window block value Y P15 Reslt window 3 NOK gt Window was not in specs OK gt Window was in specs OFF gt Window was not activated P16 Statistics window 3 Floating point number with unit P17 Window 3 entry X coordinate Floating point number with unit P18 Window 3 entry Y coordinate Floating point number with unit P19 Window 3 exit X coordinate Floating point number with unit for block window block value X P20 Window 3 exit Y coordinate Floating point number with unit for block window block value Y 113 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 9 3 Statistics 3 3 9 3 4 FSTX Window statistics With the command FSTX the window statistics can be read out The window statistics informs how strong each window is engaged in a total NOK result All data is given in percent of the NOK counter For Window type OFF and no measurement since last reset 0 is transferred Host sends lt Address gt sr lt STX gt FSTX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Statistics window 1 Floating point number with unit 76 P2 Statistics window 2 Floating point number with unit 96 P3 Statistics window 3 Floating point num
47. 10 2 6 TGEW trend weighting Input of a new value With the TGEW command the trend weighting can be set Host sends DIGIFORCE answers Host sends Meaning of parameter Pn lt Address gt sr lt STX gt TGEW P1 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Weighting for trend tracking Valid range 1 to 20 Readout of present value With the TGEW command the trend weighting can be queried Host sends DIGIFORCE answers Host sends Host sends DIGIFORCE answers Host sends DIGIFORCE answers Meaning of parameter Pn lt Address gt sr lt STX gt TGEW lt ETX gt lt BCC gt lt ACK gt lt EOT gt lt Address gt po lt ENQ gt lt STX gt P1 lt ETX gt lt BCC gt lt ACK gt lt EOT gt P1 Weighting for trend tracking Valid range 1 to 20 127 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 10 2 7 HSTA envelope available or not With the HSTA command it can be queried whether an envelope is available or not Host sends lt Address gt sr lt STX gt HSTA lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Envelopes available status 0 gt there is no envelope 1 gt an envelope is available 3 3 10 2 8 RESH reset envelope With the RESH command the envel
48. CE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 User defined unit Y channel Character chain of max 4 figures 60 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 1 6 AUSC Switch on off of Auto Scaling Input of a new value With the command AUSC the Auto Scaling of the graphical display can be switched on and off In case of a switched on Auto Scaling the device will look always for the optimal scale range When this feature is switched off the scaling is done by the manually configurable scale data This input is valid only for the present Measurement program Host sends lt Address gt sr lt STX gt AUSC P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Auto Scaling 1 gt Switch on Auto Scaling 0 gt Switch off Auto Scaling Readout of the present value With the command AUSC the present status of Auto Scaling can be read out Host sends lt Address gt sr lt STX gt AUSC lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT
49. DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 Switch trend on off 0 gt Trend env c off trend online window off trend block window off 1 gt Trend env c on trend online window on trend block window on 2 gt Trend env c on trend online window on trend block window off 3 Trend env c on trend online window off trend block window on 4 gt Trend env c on trend online window off trend block window off 125 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 10 2 5 TDEY trend delta Y value Input of a new value With the TDEY command the delta Y value of the trend can be set Host sends DIGIFORCE answers Host sends Meaning of parameter Pn lt Address gt sr lt STX gt TDEY P1 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Trend delta Y value Floating point number without unit Readout of present value With the TDEY command the delta Y value of the trend can be queried Host sends DIGIFORCE answers Host sends Host sends DIGIFORCE answers Host sends DIGIFORCE answers Meaning of parameter Pn lt Address gt sr lt STX gt TDEY lt ETX gt lt BCC gt lt ACK gt lt EOT gt lt Address gt po lt ENQ gt lt STX gt P1 lt ETX gt lt BCC gt lt ACK gt lt EOT gt P1 Current delta Y value of the trend Floating point number with Y unit 126 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3
50. ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Turning point XMAX gt Turning point at maximum displacement YMAX gt Turning point at maximum force 95 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 6 6 STMD Start mode Input of a new value With the command STMD the Start Stop mode can be defined It is determined if the measurement is controlled externally or internally after reaching a certain value limit This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt STMD P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Start mode EXTERN gt Start Stop controlled by PLC Field bus INTERNX gt Start Stop controlled by internal threshold value X channel Readout of the present value With the command STMD the present Start Stop mode can be read out Host sends lt Address gt sr lt STX gt STMD lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Start mode EXTERN gt Start Stop controlled by PLC Fi
51. GIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter 1 Meaing X Value y P1 Block Measurement 0 Measurement blocked 1 gt Measurement released Readout of the present value With the command MEFR the present status of the block on measurement can be read out Host sends lt Address gt sr lt STX gt MEFR lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Paramter 1 Meaing X Value _ P1 Block Measurement 0 Measurement blocked 1 gt Measurement released 49 BA_9310 Vxxx0_EN_2015 03 05 doc Me 3 2 10 READY Mode 3 2 10 1 RDYM Activate READY Mode Input of a new value With the command RDYM the Ready Mode can be switched on and off In READY Mode PC controlled the device waits for the PC to release the signal before setting the READY signal after a measurement Host sends lt Address gt sr lt STX gt RDYM P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Ready Mode 0 gt READY Mode normal 1 gt READY Mode PC controlled Readout of present value With the command RDYM the p
52. Host sends lt Address gt sr lt STX gt AEFH lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Envelope display in window setup menu 0 gt envelope is not displayed 1 gt envelope is displayed 144 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 11 Remaining blade thickness RBD Plate pack thickness BPD Commands on this optional function are on request Pleae call burster prazisionsmesstechnik gmbh amp co kg Gernsbach Germany 49 7224 6450 145 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 4 Commands optimized in respect of transfer time 3 4 1 Transfer of the measurement curve 3 4 1 1 MRED Command Input of a new value With the MRED command the reducing factor can be set with which the curve is transferred using the KURX and KURY commands The values 1 to 20 can be set 1 means no reduction Example a reducing factor of 4 means that when the KURX and KURY commands are applied only every 4th value is transferred The first and last values of the measurement curve are always transferred independent of the set reducing factor Host sends lt Address gt sr lt STX gt MRED P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of para
53. IFORCE answers lt STX gt P41 P42 P43 P80 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter P1 P4000 X values of the reference curve Hex values without 0 termination 136 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 10 3 9 RYMI delta Y minimum values of the reference curve RYMI Values from host to unit With this command the delta Y minimum values of the reference curve are transferred from the host to the unit The delta Y minimum values are transferred in blocks of up to 20 values parameters 2 to 21 Parameter 1 is the block number With a maximum of 4000 values there is thus a maximum of 200 blocks The block number therefore gives the number of blocks which each contain 20 values Full 20 value containing blocks must always be transferred However the unit only considers values up until the number of values has been reached In the last block any of the 20 values which remain unfilled can be padded with dummies The number of values must therefore be transferred prior to this command using the command RANZ Host sends lt Address gt sr lt STX gt RYMI P1 P2 P21 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Block number Integer value 1 to 200 P2 P21 Delta Y minimum values of the reference Hex values without 0 curve termination RYMI Values from unit to host With this command th
54. K text symbol SMILEY display a round Smiley Readout of the present value With the command INGR the presently chosen graphical symbol can be read out Host sends lt Address gt sr lt STX gt INGR lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Choose the graphical TEXT display OK NOK text symbol SMILEY gt display a round Smiley 52 BA_9310 Vxxx0_EN_2015 03 05 doc 3 2 13 Choose Measurement menu 3 2 13 1 MENU Choose Measurement menu With the command MENU the Measurement menu can be chosen Host sends lt Address gt sr lt STX gt MENU P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value Measurement display curve Meas display single window evaluation Meas display NOK statistics of windows Meas display total result Meas display general curve data With the command MENU the presently configured Measurement menu can be read out Host sends lt Address gt sr lt STX gt MENU lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC
55. MAT Gateway Address Long 32 Bit HEXFORMAT UDP Port number Integer 16bit decimally 36 BA_9310 Vxxx0_EN_2015 03 05 doc a 3 2 6 2 PORT UDP port number Input of a new value With the command PORT the UDP port number can be set Host sends lt Address gt sr lt STX gt PORT P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter P1 meaning Port number value Short 16 Bit Readout of the present value With the command PORT the UDP port number can be read out Host sends lt Address gt sr lt STX gt PORT lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers Meaning of parameter Pn lt EOT gt Parameter P1 meaning Port number value Short 16 Bit 37 BA_9310 Vxxx0_EN_2015 03 05 doc 3 2 6 3 IPVE Software version of the Ethernet modul Readout of the present value With the command IPVE the software version of the Ethernet modul can be read Host sends DIGIFORCE antswers Host sends Host sends DIGIFORCE answers Host sends DIGIFORCE answers Meaning of parameter Pn Parameter lt Address gt sr lt STX gt IPVE lt ETX gt lt BCC gt lt ACK gt lt EOT gt lt Address gt po lt ENQ gt lt STX gt
56. Measurement menu release 3 3 2 1 MFRE Measurement menues Input of a new value With the command MFRE the display of the separate measurement menues can be activated This setting depends on the measurement program Host sends lt Address gt sr lt STX gt MFRE P1 P2 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Measurement menu MESS1 gt Menu 1 Curve display MESS2 gt Menu 2 Window evaluation MESS3 gt Menu 3 Window statistics MESSA gt Menu 4 Total evaluation MESS5 gt Menu 5 General curve data P2 Display 0 gt do not show menu 1 gt show menu Readout of the present value With the command MFRE the display of the separate measurement menues can be read out There are two possibilities the direct request for release of a single menu or the general request for menu release Direct request for release of a single menu Host sends lt Address gt sr lt STX gt MFRE P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P2 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Measurement menu MESS1 gt Menu 1 Curve display MESS2 gt Menu 2 Window evaluation MESS3 gt Menu 3 Window statistics MESSA gt Menu 4 Total
57. O the burster Logo in the start up menue can bei switched ON OFF Host sends DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn lt Address gt sr lt STX gt LOGO P1 lt ETX gt lt BCC gt Parameter Meaning value P1 Burster Logo during start up menue 1 gt Logo appears 0 gt Logo does not appear Readout of the present value With the command LOGO the status of the burster Logo during start up menue can bei read out Host sends lt Address gt sr lt STX gt LOGO lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE antswers lt EOT gt Meaning of parameter Pn Parameter Meaning value P1 Burster Logo during start up menue 1 gt Logo appears 0 gt Logo does not appear 55 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 Program specific setup 3 3 1 General programm settings 3 3 1 1 PRNR Program number Input of a new value With the command PRNR a new Measurement program can be chosen Host sends lt Address gt sr lt STX gt PRNR P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value Readout of the present value With the command PRNR the number of the presently configured Measure
58. OTS THEN PRINT Comunication error not EOT received but ant RINT Program has ended successfully END 17 burster BA_9310 Vxxx0_EN_2015 03 05 doc burster 2 3 9 2 Communication with Fast Selection REM ck ck Ck ck kk kk Ck kk ck kk kk kk ck Sk Sk ck kk Sk ck Sk ck ck ck kk ck Sk ck kk kk ck Sk ck kk ck ck ck kk ck ck kk kk Sk ko Sk ko Sk ko Sk kv ko ko ko REM k k k REM 9310_2 bas Developped by MN Li KK REM Prog language Qbasic 4 5 OK REM Communication exe File created with QB 4 5 d REM with fast selection date 13 03 2000 Mk REM example ask for ID string with fast selection RE Rem Ck ck Ck ck kk kk kk Sk ck kk Ck kk ck Sk ck kk kk ck Sk ck Sk ck ck ck kk ck Sk ck kk kk ck Sk ck ck ck ck ck ck Sk ck kk kk ko ko ck ko Sk ko Sk ko ko kv ko ko ko REM Definition of ASCII Control Characters REM STX Start of text 0x02 STXS CHRS 2 REM ETX End of text 0x03 ETXS CHRS 3 REM EOT End of transmission 0x04 EOTS CHRS 4 2 3 Ss ial z 10 E Enquiry 0x05 R 5 ti Z 10 in ll Q I REM ACK Acknowledge 0x06 ACKS CHR 6 M LF line feed 0x0a CHR 10 M CR carriage return 0Ox0d ES CHRS 13 REM NAK not acknowledge 0x15 NAKS CHRS 21 REM HERE TTE RE REEBERERBERBEBRERBYM BA AMAA GAY REM Dialog Selection and opening initialisation of PC Interface REM 4 F HEFT ECTRETTTTTTTETTREETETTTBRERETBBTR AB BB BBBEYAY CLS IN
59. PUT 1 3 REM new char should be an ACK 16 BA_9310 Vxxx0_EN_2015 03 05 doc ono Ww Uw A Fl gt H J td zx D w De W i P R I wv cd ME ot F ant lt gt ACKS THEN PRINT Comunication error not ACK received but ant RINT selection supervisory string sent EM press enter to proceed NPUT ENTER TO GO ON a a M Sending command INFO to 9310 enclosed with STX and ETX INT 3 STXS INFO ETXS BI M clear answer string t 2 M read characters from serial interface t INPUTS 1 3 gt Gl M new char should be an ACK ant lt gt ACKS THEN PRINT Comunication error not ACK received but ant M IMPORTANT de adress before start polling INT 3 EOTS INT ID Enquiry sent M press enter to proceed PUT ENTER TO GO ON a aS z Gl M 9310 wants to answer now and waits for polling M start polling INT 3 00 po ENQS A GI Gl M clear answer string t u ie M initialize variable char to anything but ETX ar STXS M read from serial interface until ETX and add to answer string HILE char lt gt ETXS char INPUTS 1 3 ant ant chars BI oco D END EM ID string received send ACK RINT 3 ACK EM Printing Dev 0 INFO on PC sreen RINT DEVICE 0 answers ant EM Reading EOT from 9310 nt nt INPUTS 1 3 EM new char should be an EOT F ant lt gt E
60. PUT Which interface do you want to use 1 gt COMI 2 gt COM2 a F a lt gt 1 AND a lt gt 2 THEN PRINT illegal Interface END F a 1 THEN com COMI F a 2 THEN com COM2 openstr com 9600 N 8 1 PRINT REM rs232 initialisation OPEN openstr FOR RANDOM AS 3 PRINT Please set up the 9310 with PRINT baudrate 9600 Data bits 8 PRINT Stopp bits 1 No parity no blockcheck PRINT adress 0 PRINT REM 4 HERRERA TERT EE A O O FEF E AE FEE FEE EEE BBAAAAY REM Ask Device adr 0 for ID String with Mode fast selection REM one of the two communication modes REM All commands in the user manual are described in this mode REM FAEEELEEEE ELEAF ELEAF EEE o o ELEAF ELE EEF EEF EEE EEE EEE o EEE E ET PRINT gt gt gt gt gt Connecting Device with adress 0 REM send EOT first to end other probably un answered enquiries strongly recommended PRINT 3 EOTS REM Create and send command PRINT 3 00 sr STXS INFO ETXS es REM clear answer string ant REM read characters from serial interface ant INPUTS 1 3 18 BA_9310 Vxxx0_EN_2015 03 05 doc M new char should be an ACK ant lt gt ACKS THEN PRINT Comunication error not ACK received but ant PUR EM press enter to proceed NPUT ENTER TO GO ON aS aS EM IMPORTANT de adress before start polling RINT 3 EOTS Gl M 9310 wants to answer now an
61. Parameter Meaning Value P1 Address for PROFIBUS interface 0 127 44 BA_9310 Vxxx0_EN_2015 03 05 doc WE 3 2 7 2 PBUE PROFIBUS Control This command only exists in the instrument if the option PROFIBUS DP is installed If this is not the case the request will be answered by NAK Input of a new value With the command PBAD the present PROFIBUS control can be activated Host sends lt Address gt sr lt STX gt PBUE P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Internal PROFIBUS control 0 Control deactivated 1 gt Control activated Readout of the present value With the command PBUE the status of the PROFIBUS control can be read out Host sends Address sr STX PBUE ETX sBCC DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Internal PROFIBUS control 0 gt Control deactivated 1 gt Control activated 45 BA_9310 Vxxx0_EN_2015 03 05 doc un 3 2 7 3 PBIN Digital Inputs This command only exists in the instrument if the option PROFIBUS DP is installed If this is not the case the request will be answered by NAK Input of a new value With
62. R command the delta Y value of the envelope can be queried Host sends lt Address gt sr lt STX gt HXGR lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P4 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value with X unit with X unit with X unit with X unit 124 BA_9310 Vxxx0_EN_2015 03 05 doc m 3 3 10 2 4 TREN switch trend on off Input of a new value With the TREN command the envelope can be switched on or off Host sends lt Address gt sr lt STX gt TREN P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn P1 Switch trend on off 0 gt Trend env c off trend online window off trend block window off 1 gt Trend env c on trend online window on trend block window on 2 gt Trend env c on trend online window on trend block window off 3 Trend env c on trend online window off trend block window on 4 gt Trend env c on trend online window off trend block window off Readout of present value With the TREN command it can be queried whether trend is switched on or off Host sends lt Address gt sr lt STX gt TREN lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt
63. TR P1 P2 P21 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Block number Integer value 1 to 200 P2 P21 Y difference values of the reference Hex values without 0 curve termination 155 BA_9310 Vxxx0_EN_2015 03 05 doc fen KYTR Transfer values from unit to host in an optimized manner With this command the Y mean values normalized integer values values corrected by the zero point without taking into account the gradient of the reference curve can be transferred from the unit to the host The first value is transferred as an absolute value all other values are transferred as a difference from the preceding value If more that two sequential difference values are the same then these are no transferred individually but rather in the following form M lt factor gt lt difference value gt M is the marker that indicates that this is not a single difference value It is followed by a factor that indicates the number of sequential difference values that are the same The character separates factor and difference value It is followed by the difference value The parameter separator between the individual values is the comma 20 values are always transferred then a LF is transferred After host acknowledgement with ACK the next 20 value pairs are transferred and so on Querying continues until there are no more available measurements If the last block has le
64. TX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Password protection 0 deactivate password protection 1 gt activate password protection Readout of the present value With the command PASP the present status of password protection can be read out Host sends lt Address gt sr lt STX gt PASP lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Password protection 0 deactivate password protection 1 gt activate password protection 30 BA_9310 Vxxx0_EN_2015 03 05 doc WR 3 2 1 4 ZUGR Access levels Input of a new value With the command ZUGR the access to the configuration menues with an activated password protection can be defined Host sends lt Address gt sr lt STX gt ZUGR P1 P2 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Access levels GRUND Basic menu ESSP gt Measurement program RE gt Statistics reset KANAL gt Channel settings SV gt Measurement mode BEWER gt Evaluation SCHAL gt Switch points EINRI gt Teach in mode P2 Access for User 0 gt Access denied 1 gt Access allowed
65. a commad name 4 ASCII characters B command type read out l set S space 0x20 P1 P2 Px Parameter 1 x separated by comma lt LF gt Line Feed Ox0A 2 3 7 3 Strukture of an answer on a aaaa command Command aaaa lt LF gt aaaa commad name 4 ASCII characters B command type read out set lt LF gt Line Feed 0x0A DIGIFORCE 9310 answers example with three parameters P1 lt NUL gt P2 lt NUL gt P3 lt NUL gt lt LF gt Px Parameter x lt NUL gt NUL sign ASCII code 0x00 lt LF gt Line Feed 0x0A Note One exception forms the KURV Command with no lt NUL gt sign within the answer 13 BA_9310 Vxxx0_EN_2015 03 05 doc ad 2 3 8 Examples of the communication sequence The following sequence illustrates the DIGIFORCE 9310 communicating with a host controller in the two communications modes selection with response and fast selection In the example the INFO query command is used the 9310 has address 00 and block check is disabled in one example the block check is also shown for the given command the given data 2 3 8 1 Communication Selection with response sample Host sends lt EOT gt to make sure that any open connections are terminated and the 9310 receive buffer is cleared Host sends O0sr ENQ Selection DIGIFORCE 9310 with address 0 is addressed 9310 answers lt ACK gt Acknowledge from 9310 Host sends Blockcheck OFF lt STX gt info lt LF gt lt ETX
66. acter chain of max 12 figures 57 BA_9310 Vxxx0_EN_2015 03 05 doc s 3 3 1 3 NAME Program name on each measurement program Input of a new value With the command NAME a name for any measurement program can be set The command does not choise a measure program Host sends lt Address gt sr lt STX gt NAME P1 P2 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of paramter Pn Parameter Meaning value P1 Measurement prog number 0 7 P2 Measurement prog name String max 12 character Readout of the present value With the command NAME the name for any measurement program can be read out Host sends lt Address gt sr lt STX gt NAME P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P2 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of paramter Pn Parameter Meaning value P1 Measurement prog number 0 7 P2 Measurement prog name String max 12 character 58 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 1 4 BDEX User defined unit X channel Input of a new value With the command BDEX a string as user defined unit for Measurement channel X can be configured This input is valid only for the present Measurement program Host sends lt Address gt sr lt STX gt BDEX P1 lt ETX
67. ad out of all window evaluation values Host sends lt Address gt sr lt STX gt FALL lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P20 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning value P1 X unit String P2 Y unit String P3 Reslt window 1 NOK gt Window was not in specs OK gt Window was in specs OFF gt Window was not activated P4 Statistics window 1 Floating point number with unit 96 P5 Window 1 entry X coordinate Floating point number with unit P6 Window 1 entry Y coordinate Floating point number with unit P7 Window 1 exit X coordinate Floating point number with unit for block window block value X P8 Window 1 exit Y coordinate Floating point number with unit for block window block value Y P9 Reslt window 2 NOK gt Window was not in specs OK gt Window was in specs OFF gt Window was not activated P10 Statistics window 2 Floating point number with unit 96 P11 Window 2 entry X coordinate Floating point number with unit P12 Window 2 entry Y coordinate Floating point number with unit P13 Window 2 exit X coordinate Floating point number with unit for block window block value X P14 Window 2 exit Y coordinate Floating point number
68. ain unfilled can be padded with dummies The number of values must therefore be transferred prior to this command using the command RANZ Host sends lt Address gt sr lt STX gt KYSU P1 P2 P21 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Block number Integer value 1 to 200 P2 P21 Difference Y cumulative values of the Hex values without 0 reference curve termination 153 BA_9310 Vxxx0_EN_2015 03 05 doc lian KYSU Transfer values from unit to host in an optimized manner With this command the Y cumulative values normalized value values corrected by the zero point without taking into account the gradient of the reference curve can be transferred from the unit to the host The first value is transferred as an absolute value all other values are transferred as a difference from the preceding value If more that two sequential difference values are the same then these are no transferred individually but rather in the following form M lt factor gt lt difference value gt M is the marker that indicates that this is not a single difference value It is followed by a factor that indicates the number of sequential difference values that are the same The character separates factor and difference value It is followed by the difference value The parameter separator between the individual values is the comma 10 values are alway
69. ameter Meaning Value P1 Tolerance value for sensor test Y Floating point numbers without unit 88 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 5 5 STST Execute sensor test With the command STST the sensor test is executed and the result is transferred Host sends lt Address gt sr lt STX gt STST lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Result of sensor test 10 gt Sensor is within the specs NIOX gt X Sensor is out of tolerance NIOY gt Y Sensor is out of tolerance NIOXY gt X und Y Sensor are out of tolerance 3 3 5 6 STWX Reference value for sensor test channel X Input of a new value With the command STW X the reference value for sensor test X can be entered The value is given in the present X unit This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt STWX P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Reference value for sensor test X Floating point numbers without unit Readout of the present value With the command STWX the present reference value for senso
70. ameter separator between the discrete values is the comma 10 value pairs are always transferred then an LF follows After confirmation of receipt of the host with ACK the next 10 value pairs are being transferred etc The readout repeats again and again until no more measurement values are available The transfer always consists of a group of 10 value pairs If at the end there are less than 10 value pairs left the transfer of the last value pair is repeated until the block of 10 is filled up The measurement value arise from e g Yn MY KY unit Y Axis This information need to be read out first of all with the KRVA command Host sends lt Address gt sr lt STX gt KURV lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt X1 Y1 X2 Y2 X3 V3 X4 Y 4 X5 Y Xo Yo X7 Y 7 Xa Y a Xo Y o X40 Y 40 LF lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt STX gt X11 Y11 X20 Yo LF lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Whereas X1 Y1 are the coordinates for the first point of the curve With the command KURV data in the output buffer arosen from an interrupted KURV command could be erased 116 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 10 Envelope 3 3 10 1 Evaluation result 3 3 10 1 1 HERG Envelope evaluation result With the command HERG The evalua
71. ansferred difference values and the absolute values calculated from them are normalized integer values 16 bit These values are used with the gradient values which are retrieved using the KRVA command to calculate the floating point values in their respective units Floating point value Normalized absolute value gradient Host sends lt Address gt sr lt STX gt K YMA lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P20 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt STX gt P21 P22 P23 P40 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 P4000 Y difference values of the delta Y maximum values of the Hex values without 0 reference curve termination 160 BA_9310 Vxxx0_EN_2015 03 05 doc 3 5 9310 V2xxx specific commands Black box module 3 5 1 TRAX Transmitter supply X channel Input of a new value With the command TRAX The transmitter supply of chaanel X can be switched Host sends lt Address gt sr lt STX gt TRAX P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Transmitter supply for channel X 0 gt OFF 1 gt ON Readout of present value With the command TRAX the present status of the transmitter supply can be r
72. arameter separator between the individual values is the comma 20 values are always transferred then a LF is transferred After host acknowledgement with ACK the next 20 value pairs are transferred and so on Querying continues until there are no more available measurements If the last block has less than 20 difference values then transfer is terminated early If there are no more available measurements then an EOT is sent in response to the ACK acknowledgement The host must calculate the absolute values from the difference values with the exception of the 1st value Absolute value n absolute value n 1 difference value n The transferred difference values and the absolute values calculated from them are integer values 16 bit These values are used with the zero point and gradient values which are retrieved using the KRVA command to calculate the floating point values in their respective units Floating point value absolute value zero point gradient Host sends lt Address gt sr lt STX gt KURX P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt absi dif 2 difs dif 4 difs dif dif difg dif 2 LF lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt STX gt dif2 dif 49 LF lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt The command KURX
73. arning LED can be tested Host sends lt Address gt sr lt STX gt ALED P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Switch warning LED on off 0 gt warning LED on 1 gt warning LED off There is no xxx Form of this command 3 7 11 RESE Test of the RESET button Readout of present value With the command RESE The status of the reset button can be read out Host sends lt Address gt sr lt STX gt RESE lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Status of the reset button 0 gt RESET button is pressed 1 gt RESET button is not pressed 174
74. ation begins the transfer with lt STX gt Then the corresponding data is sent The data block is terminated with lt ETX gt The lt ETX gt character is followed by the optional block check character lt BCC gt This is formed from all the bytes that come after lt STX gt including lt ETX gt The lt BCC gt is generated by performing an exclusive OR operation on all these bytes 80hex is also XOR ed with the result of this operation in order to prevent any possible mix up with control characters The slave station sends one of two possible responses after detecting the lt BCC gt e f the data has been accepted and the station is ready to receive new data it sends lt ACK gt On receiving this the master station either sends new data or terminates the data transfer e Ifthe data was not accepted and the slave station is ready to receive new data it sends lt NAK gt On receiving this the master station may send other data or terminate the connection 2 3 6 Terminating a connection The master station sends lt EOT gt to indicate that it has no more data to transfer lt EOT gt returns the master status to the control station 12 BA_9310 Vxxx0_EN_2015 03 05 doc 2 3 7 Command structure 2 3 7 1 Commands without parameters aaaaB lt LF gt aaaa commad name 4 ASCII characters B command type read out set lt LF gt Line Feed 0Ox0A 2 3 7 2 Commands with parameters aaaaB lt S gt P1 P2 Px lt LF gt aaa
75. ber of sequential difference values that are the same The character separates factor and difference value It is followed by the difference value The parameter separator between the individual values is the comma 20 values are always transferred then a LF is transferred After host acknowledgement with ACK the next 20 value pairs are transferred and so on Querying continues until there are no more available measurements If the last block has less than 20 difference values then transfer is terminated early If there are no more available measurements then an EOT is sent in response to the ACK acknowledgement The host must calculate the absolute values from the difference values with the exception of the 1st value Absolute value n absolute value n 1 difference value n The transferred difference values and the absolute values calculated from them are integer values 16 bit These values are used with the zero point and gradient values which are retrieved using the KRVA command to calculate the floating point values in their respective units Floating point value absolute value zero point gradient Host sends lt Address gt sr lt STX gt KURY P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt absi dif 2 dif 3 dif 4 dif 5 dif dif difg dif 2 LF lt ETX gt lt BCC gt Host sends lt ACK gt
76. ber with unit 96 114 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 9 4 Measurement curve 3 3 9 4 1 KRVA General Measurement curve data With the command KRVA all general information that are necessary for reading and interpreting the curve can be read out With the help of the M and K values the numbers transferred with the curve can be converted into floating point values Host sends DIGIFORCE answers Host sends Host sends DIGIFORCE answers Host sends DIGIFORCE answers lt Address gt sr lt STX gt KRVA lt ETX gt lt BCC gt lt ACK gt lt EOT gt lt Address gt po lt ENQ gt lt STX gt P1 P2 P3 P4 P5 P6 P7 P8 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Unit X Axis Character chain with 4 figures P2 Unit Y Axis Character chain with 4 figures P3 M X Axis Floating point number P4 M Y Axis Floating point number P5 K X Axis Floating point number P6 K Y Axis Floating point number P7 Number of measurement 0 4000 values P8 Status 0 gt max numeber not reached Max number of values 1 gt max number is reached reached 115 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 9 4 2 KURV Measurement curve With the command KURV the complete Measurement curve can be read out The Measurement data are transferred in hexadecimal data format and without 0 termination for time reasons Par
77. burster DIGIFORCE 9310 Interface Commands RS232 485 Ethernet valid as of software version V2006 01 Status 28 February 2007 2015 burster Manufacturer prazisionsmeRtechnik gmbH amp co kg burster pr zisionsmefstechnik gmbh amp co kg All rights reserved TalstraRe 1 5 P O Box 1432 76593 Gernsbach 76587 Gernsbach 49 0 7224 645 0 Note The following information may be amended without prior notice No part of this document may be reproduced or processed using electronic system without prior consent in writing burster provides no warranty of any kind respect to this material including the implied warranty of merchantable quality and fitness for purpose burster is not liable under any circumstances for errors incidental damage or consequential loss sustained in connection with the function or use of this material 1821 BA9310Vxxx0EN 5170 031518 BA_9310 Vxxx0_EN_2015 03 05 doc burster BA_9310 Vxxx0_EN_2015 03 05 doc DIGIFORCE 9310 External Interface Commands RS232 485 Ethernet BA_9310 Vxxx0_EN_2015 03 05 doc an Table of Content T REVISION HISTORY eccl eee roce ean ea aioe es 8 2 SERIAL COMMUNICATION eeeeeee enne nnne nnn nnn n nnn nnn n nhan nnn nnn nnn 9 2 4 Serial communication during measurement access eee 9 2 2 Interface parameter of the serial RS232 485 interface eeseeeeeeeses 9 2 3 Communicat
78. ch point can be defined In case of Absolute reference or Block reference of the measurement curve the switch point refers to the absolute zero point with an active Trigger reference it refers to the trigger value This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt SCHA P1 P2 P3 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Channel X gt X channel Y gt Y channel P2 Switch point value Floating point number without unit P3 Reference ABS gt Reference Absolute TRIG gt Reference Trigger Only channel X and if Trigger is active Readout of the present value With the command SCHA the settings for the first switch point can be read out Host sends lt Address gt sr lt STX gt SCHA lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Channel X gt X channel Y gt Y channel P2 Switch point value Floating point number without unit P3 Reference ABS gt Reference Absolute TRIG gt Reference Trigger Only channel X and if Trigger is active 103 BA_9310 Vxxx0_EN_2015 03
79. channel sse 84 3 3 5 Sensortest rst etn niue NE E E 85 3 3531 SETX Leachein s nsor test X 2 onn egenis ise 85 32352 SETY Teach in sensor test Y 5 nnt eat es 86 35 3 53 STTX Tolerance sensor test X i o tn ctc ce ex detta edem eta et RS 87 3 3 5 4 STIY Tolerance sensor test Y oi neu d eite ett een 88 3 532565 SESE Exec te sensor test sce t pt epe er t Een 89 3 3 5 6 STWX Reference value for sensor test channel X esses 89 3 3 5 7 SsTWY Reference value for sensor test channel Y eese 90 3 3 6 Setting of measurement function sss nennen nnn nnns 91 3 3 6 1 MFKT Measurement function esses enne rina 91 3 9 6 2 RAST Sampling rate teen eed eee dci pde etre de tee ce dev NTEN 92 3 8 267 3 YvBAUG Reference ette eee bietet E E 93 9eouod TREE Tigger POM 2 nitide mI Deu 94 3 926 5 URET TUNING POMS ze enean tet hme ex de eee osten da 95 35 346 2 6 STIMD otart mode o i ef et tem et bar i c Lt ee f ere 96 3 3 6 7 STSP Start Stopintermnaln enaa ara ee a eka aaa a aa aaa ener 97 3s 3 08 STAR PLG Tare funtion riina ume Tae AEE aa aTe DIN aE Ae DEEE aaa AT 98 3 3 6 9 TARA Start Function via interface esses 98 3 3 7 Evaltuatioft iu dede eigen ierunt us divitis deii 99 3 3 7 1 WIDOW estear einn tar a beets das E Eaa Eer dads Eria EA er seg etvidek Ta Ea iia E a a 99 3 3 7 2 SwWitch Dolrits ahea e iaaa a
80. command UINT device internal voltage signals can be read out Host sends lt Address gt sr lt STX gt UINT lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P4 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 Supply X channel Float value in V approx 5 V not for Piezo interface approx 2 5 V or 5 V Kurzschluss Nullpunkt Float approx 0 V 171 BA_9310 Vxxx0_EN_2015 03 05 doc 3 7 8 ROHW A D converter and voltage values Readout of present value With the command ROHW A D converter and voltage values can be read out Host sends lt Address gt sr lt STX gt ROHW lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P4 P5 P6 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 A D converter X channel Integer Voltage value X channel Unit of X channel voltage value A D converter Y channel Voltage value X channel DMS type Float Charge of Y channel Piezo type Unit of Y Kanal voltage or charge 172 BA_9310 Vxxx0_EN_2015 03 05 doc 3 7 9 Test of the PLC inputs and outputs 3 7 9 1 SPSI Read the PLC inputs With the command SPSI the nine PLC inputs ca
81. curve TREND gt display of the trend limits with window Readout of present value With the AEFK command the display selection when setting up the window can be queried Current curve reference curve trend curve Host sends lt Address gt sr lt STX gt AEFK lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 What is displayed in the window setup menu MESS gt display of the current measurement curve REF gt display of the reference curve TREND gt display of the trend limits with window 143 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 10 4 4 AEHF switch on off envelopes display in the window setup menu Input of a new value With the AEFH command envelopes display in the window setup menu can be switched on or off If envelope is not activated then envelope display cannot be switched on Host sends lt Address gt sr lt STX gt AEFH P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn P1 Envelope display in window setup menu 0 gt envelope is not displayed 1 gt envelope is displayed Readout of present value With the AEFH command it can be queried whether envelope display in the window setup menu is switched on or off
82. d The instrument enters the initial state and waits for new commands The timeout for Timer B is set to 5 seconds 22 BA_9310 Vxxx0_EN_2015 03 05 doc m 2 4 2 Information about the command descriptions In the following command examples only connection establishment with fast selection is described Selection with response can obviously also be used It is recommended that before each command sequence an lt EOT gt is sent to the 9310 This clears the receive buffers so that no previously sent characters e g sent during interface initialization can cause an erroneous command interpretation Meaning of the symbol syntax used in the following examples Address lt STX gt 0x02 ETX 0x03 lt ENQ gt 0x05 lt ACK gt 0x06 lt NAK gt 0x15 LF Ox0A lt EOT gt 0x04 lt NUL gt 0x00 lt S gt 0x20 gt device address 00 99 gt Start of Text gt End of Text gt Enquiry gt Acknowlege gt Not Acknowlege gt Line Feed gt End Of Transmission gt NUL sign gt Space A Caution Important notes e Only the commands described in this operating manual should be used Use of undocumented commands can cause incorrect unit operation No commas can occur within a parameter A point is used in floating point numbers The number of parameters must always be adhered to Command transfer must take exclusively in upper or lower case 23 BA_9310 Vxxx0_EN_2015 03 05 doc um 3 I
83. d waits for polling M start polling INT 3 oo po ENQS AG Gl M clear answer string t u el EM initialize variable char to anything but ETX har STX EM read from serial interface until ETX and add to answer string HILE char lt gt ETXS char INPUT 1 3 ant ant char WEND REM ID string received send ACK PRINT 3 ACK REM Printing INFO on PC sreen PRINT Device 0 answers ant REM Reading EOT from 9310 ant ant INPUT 1 3 REM new char should be an EOT IF ant lt gt EOT THEN PRINT Comunication error not EOT received but ant PRINT Program has ended successfully END 19 burster BA_9310 Vxxx0_EN_2015 03 05 doc With a data set of more than 7500 byte the data packet must become fragmented divided see example The DIGIFORCE 9310 supports coded more burster internally and unencrypted UDP frames this can be configured in the equipment default is coded and not coded 2 3 10 Construction and fragmentation of Ethernet UDP frames Telegram format from 9310 to host Format with data answer to xxxx command lt STX gt Key Identifier Status Number Data End sign gt Block Check Format without data error or no xxxx command lt STX gt Key Identifier Status Number End Sign gt Block Check STX 0x02 Key 0 message is not coded 1 message is coded Identifier continuous number 1 999 ASCII 9310 answers with the sa
84. doc lian KYMI Transfer values from unit to host in an optimized manner With this command the minimum Y values normalized integer values values corrected by the zero point without taking into account the gradient of the reference curve can be transferred from the unit to the host The first value is transferred as an absolute value all other values are transferred as a difference from the preceding value If more that two sequential difference values are the same then these are no transferred individually but rather in the following form M lt factor gt lt difference value gt M is the marker that indicates that this is not a single difference value It is followed by a factor that indicates the number of sequential difference values that are the same The character separates factor and difference value It is followed by the difference value The parameter separator between the individual values is the comma 20 values are always transferred then a LF is transferred After host acknowledgement with ACK the next 20 value pairs are transferred and so on Querying continues until there are no more available measurements If the last block has less than 20 difference values then transfer is terminated early If there are no more available values then an EOT is sent in response to the ACK acknowledgement There may be up to 4000 values Thus there may be up to 200 blocks The host must previously have retrieved the number of
85. dress gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P4 P5 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Strain gage yes or no 1 gt Strain gage 0 gt no strain gage but standard signal P2 Input terminal voltage 2 5V gt 2 5V input voltage 5V___ gt 5V input voltage P3 Sensitivity in mV V Floating point numbers e g 1 498 P4 End value of sensor Floating point numbers e g 150 0 P5 Used range of sensor how great are Floating point numbers e g 125 0 the maximum sensor forces that occur in the given application 71 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 3 7 YPIE Set the range for Piezo sensor Setting of the present value With the command YPIE the input range of the PIEZO input can be selected This command is available only with the PIEZO option Host sends Address sr STX YPIE P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Input range 1NC gt Inputrange 1nC 2NC gt Inputrange 2nC 5NC gt Inputrange 5nC 10NC gt Inputrange 10nC 20NC gt Inputrange 20nC 50NC gt Input range 50nC 100NC gt Input range 100 nC 200NC gt Input range 200 nC 400NC gt Input range 400 nC Readout of the present value With the command YPIE the present input range can be read out H
86. dress gt sr lt STX gt FILX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Critical frequency of the X channel AUS gt Filter off filter 5Hz gt Filter with fy 5Hz 10Hz gt Filter with fg 10Hz 25Hz gt Filter with fy 25Hz 50Hz gt Filter with fg 50Hz 100Hz gt Filter with fy 100Hz 200Hz gt Filter with fy 200Hz 400Hz gt Filter with fy 400Hz 74 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 3 10 FILY Filter Y Input of a new value With the command FILY the filter on the Y channel can be activated This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt FILY P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Critical frequency of the Y channel AUS gt Filter off filter 5Hz gt Filter with fy 5Hz 10Hz gt Filter with fg 10Hz 25Hz gt Filter with fg 25Hz 50Hz gt Filter with f j 50Hz 100Hz gt Filter with fy 100Hz 200Hz gt Filter with fy 200Hz 400Hz gt Filter with fy 400Hz Readout of the present value With the command FIL Y the present setting for the filter o
87. ds lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P40 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt STX gt P41 P42 P43 P80 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter P1 P4000 Y mean values of the reference Hex values without 0 curve termination 139 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 10 3 12 RACC calculate envelope RACC After the reference curve has been completely received from the host the RACC command can be used to start calculation of the envelope Completely mean values the following commands must previously have been implemented RXWE or KXWE RYMI or KYMI RYMA or KYMA RYTR or KYTR RANZ Host sends lt Address gt sr lt STX gt RACC lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt There are no parameters or question form 140 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 10 4 Selecting the display from the setup menu 3 3 10 4 1 AEHK display selection in the envelopes setup menu Input of a new value With the AEHK command the display selection when setting up the envelope can be set Current curve reference curve trend curve If trend is not activated then display of the trend curve is not possible If envelope is not active then display of reference and trend curves is not possible Host sends lt Address gt sr lt STX
88. ds lt Address gt sr lt STX gt DMSY P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Y channel range DMS type 0 gt 2 5 mV range 1 gt 5mvV 2 gt 10 mV 3 gt 25 mV 4 gt 50 mV 5 gt 100 mV 6 25V Readout of present value With the commmand DMSY the current Y channel range can be read out Host sends lt Address gt sr lt STX gt DMSY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Y channel range DMS type 0 gt 2 5 mV range 1 gt 5mvV 2 gt 10 mV 3 gt 25 mV 4 gt 50 mV 5 gt 100 mV 6 gt 5V 167 BA_9310 Vxxx0_EN_2015 03 05 doc 3 7 4 PIEY Setting of Y channel range Piezo type This command is only vaild if the Test mode is active Input of a new value With the command PIEY the Y channel range of the Piezo amplifier can be set for test reason Host sends lt Address gt sr lt STX gt PIEY P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Y channel range Piezo type 0 5 1nC range 1 gt 2nC 2 2 5nC 3 gt 10nC 4 gt 20
89. e delta Y minimum values of the reference curve are transferred from the unit to the host 40 values are always transferred at the same time After polling these first 40 values are transferred Once the host has confirmed receipt with lt ACK gt the next 40 values are transferred This continues until all values have been transferred When all values have been transferred the unit answers with lt EOT gt following the lt ACK gt Full 40 value containing blocks are always transferred The last block of 40 is padded with dummies There may be up to 4000 values Thus there may be up to 100 blocks The host must previously have retrieved the number of values using the RANZ command Host sends lt Address gt sr lt STX gt R Y MI lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P40 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt STX gt P41 P42 P43 P80 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter P1 P4000 Delta Y minimum values of the reference Hex values without 0 curve termination 137 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 10 3 10 RYMA delta Y maximum value of the reference curve RYMA Values from host to unit With this command the delta Y maximum values of the reference curve are transferred from the host t
90. e is thus a maximum of 200 blocks The block number therefore gives the number of blocks which each contain 20 values Full 20 value containing blocks must always be transferred However the unit only considers values up until the number of values has been reached In the last block any of the 20 values which remain unfilled can be padded with dummies The number of values must therefore be transferred prior to this command using the command RANZ Host sends lt Address gt sr lt STX gt KYWE P1 P2 P21 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Block number Integer value 1 to 200 P2 P21 Y difference values of the reference Hex values without 0 curve termination 151 BA_9310 Vxxx0_EN_2015 03 05 doc lian KYWE Transfer values from unit to host in an optimized manner With this command the Y mean values normalized integer values values corrected by the zero point without taking into account the gradient of the reference curve can be transferred from the unit to the host The first value is transferred as an absolute value all other values are transferred as a difference from the preceding value If more that two sequential difference values are the same then these are no transferred individually but rather in the following form M lt factor gt lt difference value gt M is the marker that indicates that this is not a single difference value It is follow
91. e values are the same then these are no transferred individually but rather in the following form M lt factor gt lt difference value gt M is the marker that indicates that this is not a single difference value It is followed by a factor that indicates the number of sequential difference values that are the same The character separates factor and difference value It is followed by the difference value The parameter separator between the individual values is the comma 20 values are always transferred then a LF is transferred After host acknowledgement with ACK the next 20 value pairs are transferred and so on Querying continues until there are no more available measurements If the last block has less than 20 difference values then transfer is terminated early If there are no more available values then an EOT is sent in response to the ACK acknowledgement There may be up to 4000 values Thus there may be up to 200 blocks The host must previously have retrieved the number of values using the RANZ command The host must calculate the absolute values from the difference values with the exception of the 1st value Absolute value n absolute value n 1 difference value n The transferred difference values and the absolute values calculated from them are normalized integer values 16 bit These values are used with the gradient values which are retrieved using the KRVA command to calculate the floating point values
92. ead out Host sends lt Address gt sr lt STX gt TRAX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Value P1 Transmitter supply for channel X 0 gt Supply is switched OFF 1 gt Supply is switched ON 161 BA_9310 Vxxx0_EN_2015 03 05 doc 3 5 2 TRAY Transmitter supply Y channel Input of a new value With the command TRAY The transmitter supply of channel Y can be switched Host sends lt Address gt sr lt STX gt TRAY P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Value P1 Transmitter supply for channel Y 0 gt OFF 1 gt ON Readout of present value With the command TRAY the present status of the transmitter supply can be read out Host sends lt Address gt sr lt STX gt TRAY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Value P1 Transmitter supply for channel Y 0 gt Supply is switched OFF 1 gt Supply is switched ON 162 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 6 Error status 3 6 1 FSTA Error s
93. ed by a factor that indicates the number of sequential difference values that are the same The character separates factor and difference value It is followed by the difference value The parameter separator between the individual values is the comma 20 values are always transferred then a LF is transferred After host acknowledgement with ACK the next 20 value pairs are transferred and so on Querying continues until there are no more available measurements If the last block has less than 20 difference values then transfer is terminated early If there are no more available values then an EOT is sent in response to the ACK acknowledgement There may be up to 4000 values Thus there may be up to 200 blocks The host must previously have retrieved the number of values using the RANZ command The host must calculate the absolute values from the difference values with the exception of the 1st value Absolute value n absolute value n 1 difference value n The transferred difference values and the absolute values calculated from them are normalized integer values 16 bit These values are used with the gradient values which are retrieved using the KRVA command to calculate the floating point values in their respective units Floating point value Normalized absolute value gradient Host sends lt Address gt sr lt STX gt K YWE lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends
94. eld bus INTERNX gt Start Stop controlled by internal threshold value X channel 96 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 6 7 STSP Start Stop internal Input of a new value With the command STSP the Start Stop values for internal start X can be entered This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt STSP P1 P2 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Internal start X Floating point numbers without unit P2 Internal stop X Floating point numbers without unit Readout of the present value With the command STSP the present Start Stop values can be read out Host sends lt Address gt sr lt STX gt STSP lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Internal start X Floating point numbers without unit P2 Internal stop X Floating point numbers without unit 97 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 6 8 STAR PLC Tare function With the command STAR the PLC tare function can be configured or read out Configure PLC tare function Host sends lt Addres
95. ence curve KYMI Transfer values from host to unit in an optimized manner With this command the delta Y minimum values normalized integer values values corrected by the zero point without taking into account the gradient of the reference curve can be transferred from the host to the unit The values are transferred in hexadecimal format without 0 termination to save time The first value is transferred as an absolute value all other values are transferred as a difference from the preceding value The difference values are transferred in blocks of up to 20 values parameters 2 to 21 Parameter 1 is the block number With a maximum of 4000 values there is thus a maximum of 200 blocks The block number therefore gives the number of blocks which each contain 20 values Full 20 value containing blocks must always be transferred However the unit only considers values up until the number of values has been reached In the last block any of the 20 values which remain unfilled can be padded with dummies The number of values must therefore be transferred prior to this command using the command RANZ Host sends lt Address gt sr lt STX gt KYMI P1 P2 P21 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P2 P21 Difference values of the delta Y minimum values of the Hex values without 0 reference curve termination 157 BA_9310 Vxxx0_EN_2015 03 05
96. es sense only if window evaluation is set as type of evaluation There can be only one window of the types block and online each If a window of the same type already exists the device answers with NAK This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt FTYP P1 P2 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Window number 1 3 P2 Window type AUS gt Window is switched off DURCH Window is a pass through type BLOCK gt Window is a block type ONLINE gt Window is an online type Readout of the present value With the command FTYP the window type can be read out Host sends lt Address gt sr lt STX gt FTYP P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P2 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Window number 1 9 P2 Window type AUS gt Window is switched off DURCH gt Window is a pass through type BLOCK gt Window is a block type ONLINE gt Window is an online type 99 BA_9310 Vxxx0_EN_2015 03 05 doc ian 3 3 7 1 2 FGRZ Window borders Input of a new value With the command FGRZ the border
97. f 0 gt Envelope is switched off 1 Envelope is switched on 122 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 10 2 2 HDEY Envelope delta Y value Input of a new value With the HDEY command the delta Y value of the envelope can be set Host sends DIGIFORCE answers Host sends Meaning of parameter Pn lt Address gt sr lt STX gt HDEY P1 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Envelope delta Y value Floating point number without unit Readout of present value With the HDEY command the delta Y value of the envelope can be queried Host sends DIGIFORCE answers Host sends Host sends DIGIFORCE answers Host sends DIGIFORCE answers Meaning of parameter Pn lt Address gt sr lt STX gt HDEY lt ETX gt lt BCC gt lt ACK gt lt EOT gt lt Address gt po lt ENQ gt lt STX gt P1 lt ETX gt lt BCC gt lt ACK gt lt EOT gt P1 Current delta Y value of the envelope Floating point number with Y unit 123 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 10 2 3 HXGR Envelope X limits Input of a new value With the HXGR command Xmin and Xmax values of the envelope can be set Host sends lt Address gt sr lt STX gt HXGR P1 P2 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Xmin limit of the envelope Floating point number without unit Xmax limit of the envelope Floating point number without unit Query value With the HXG
98. gradient of the reference curve can be transferred from the unit to the host The first value is transferred as an absolute value all other values are transferred as a difference from the preceding value If more that two sequential difference values are the same then these are no transferred individually but rather in the following form M lt factor gt lt difference value gt M is the marker that indicates that this is not a single difference value It is followed by a factor that indicates the number of sequential difference values that are the same The character separates factor and difference value It is followed by the difference value The parameter separator between the individual values is the comma 20 values are always transferred then a LF is transferred After host acknowledgement with ACK the next 20 value pairs are transferred and so on Querying continues until there are no more available measurements If the last block has less than 20 difference values then transfer is terminated early If there are no more available values then an EOT is sent in response to the ACK acknowledgement There may be up to 4000 values Thus there may be up to 200 blocks The host must previously have retrieved the number of values using the RANZ command The host must calculate the absolute values from the difference values with the exception of the 1st value Absolute value n absolute value n 1 difference value n The tr
99. gt Meaning of parameter Pn Parameter Meaning Value P1 Auto Scaling 1 gt Switch on Auto Scaling 0 gt Switch off Auto Scaling 61 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 1 7 Scar Manual Scaling of Measurement curve Input of a new value With the command SCAL the graphical display limitations can be set manually This command can only be sent when Auto Scaling is switched off This input is valid only for the present Measurement program Host sends lt Address gt sr lt STX gt SCAL P1 P2 P3 P4 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Lower display limit X Floating point number without unit P2 Upper display limit X Floating point number without unit P3 Lower display limit Y Floating point number without unit P4 Upper display limit Y Floating point number without unit Readout of the present value With the command SCAL the present manual scale values can be read out Host sends lt Address gt sr lt STX gt SCAL lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P4 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Lower display limit X Floating point number without uni
100. gt 22 Readout of the present value With the command EINX the configured unit for X channel can be read out Host sends lt Address gt sr lt STX gt EINX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Unit X channel 0 gt user defined 12 gt mm 22 0 66 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 3 2 EINY Unit Y Input of a new value With the command EIN Y the unit for Measurement channel Y can be entered This input is valid only for the present Measurement program Host sends lt Address gt sr lt STX gt EINY P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Unit Y channel 0 gt user defined 19 N 2 gt kN 32 Nm Readout of present value With the command EINY the configured unit for Y channel can be read out Host sends lt Address gt sr lt STX gt EINY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn
101. gt Host sends Blockcheck ON lt STX gt info lt LF gt lt ETX gt lt BCC gt here BCC B8hex 9310 answers lt ACK gt Acknowledge from 9310 Host sends lt EOT gt The host controller unaddresses the device in order to start a polling sequence immediately Host sends 00po lt ENQ gt The 9310 with address 0 is requested to send all existing responses If block check is OFF 9310 answers lt STX gt V200101 lt NUL gt SN123456 lt NUL gt 09 03 2001 lt NUL gt lt LF gt lt ETX gt If block check is ON 9310 answers lt STX gt V200101 lt NUL gt SN123456 lt NUL gt 09 03 2001 lt NUL gt lt LF gt lt ETX gt lt BCC gt here BCC CEhex This is the correct response to the info command Host sends lt ACK gt The controller has received the response and accepted it Does the 9310 have other queries saved for which a response can now be sent 9310 answers lt EOT gt No This ends the communication sequence and the 9310 has unaddressed itself 14 BA_9310 Vxxx0_EN_2015 03 05 doc e 2 3 8 2 Communication with Fast Selection sample Host sends lt EOT gt to make sure that any existing connections are terminated and the 9310 receive buffer is cleared Host sends O0Osr lt STX gt info lt LF gt lt ETX gt Command sequence The 9310 with address 0 is to be addressed and the info command is to be executed 9310 answers lt ACK gt The 9310 signals that it accepts the addressing and recognizes and has understood the
102. he command INVX the present status of the X channel inverting can be read out Host sends lt Address gt sr lt STX gt INVX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Inverting X channel 1 gt Inverting switched on 0 gt Inverting switched off 76 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 3 12 INVY Inverting Y channel Input of a new value With the command INVY the inverting of the Y channel can be switched on and off If the device is readjusted or if the adjustment values are loaded from the EEPROM the inverting is switched off automatically This is valid also for a default adjustment in case of loss of memory This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt INVY P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Inverting Y channel 1 gt Inverting switched on 0 gt Inverting switched off Readout of the present value With the command INVY the present status of Y channel inverting can be read out Host sends lt Address gt sr lt STX gt INVY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt
103. i 2a INEO Info lines cr ete emen Seta e alee E 33 Bx 2 6202 STAN c Otfatlomnurber c a eo ec ema eee tiit M eie eec 33 3 2 J ECD Contrast 5e5 o csimumbetitsiui eut MI hin i M Ae AAE EM eA od 34 324395217 CDK DGD contrast 2t are ir ttum etti tto es 34 TUN QUI IBCuPjUo MP 35 3 2941 SPRA Menu langu age cerent tenerte tagen Rae Erde ERR enden aee tad Run EE Er 35 3 2 5 RS232 rniterface uie d ger E ge ede el reg ee delega vg dede ege age 35 BA_9310 Vxxx0_EN_2015 03 05 doc 3 2 6 332 3x2 3 2 3 2 7 3 2 8 3 2 9 3 2 3 2 10 3 2 Su 3 2 11 35 23 323 Duis 3 2 12 SZ 3 2 13 S425 3 2 14 3 2 3 2 15 Ethernet Interface Eus E eee em nds IPEX IP address Gateway address subnet mask and UDP Port PORT UDP port number esi ea 1 iecit cede tear voe ze dete due de dau a Roe du a IPVE Software version of the Ethernet modul seen COMM coded uncoded Ethernet communication eseeeee HOST Host IP addresses access restriction seeeseeene BUID 9310 device identifiers sssssessseseenennmnnnnnnn nnne MAST Ethernet host can reserve a DIGIFORCE 9310 eene SBROEIBUSRIOITa B Cra d arm son S Rud Toric bnt zu E iem REI 7 7 7 4 9 1 1 1 a 1 1 st 2 z3 PBAD PROFIBUS address sse enne nnn nn sns eni
104. iders values up until the number of values has been reached In the last block any of the 20 values which remain unfilled can be padded with dummies The number of values must therefore be transferred prior to this command using the command RANZ Host sends lt Address gt sr lt STX gt RYTR P1 P2 P21 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Block number Integer value 1 to 200 P2 P21 Y mean values of the reference Hex values without 0 curve termination RYTR Values from unit to host With this command the Y mean values normalized value values corrected by the zero point of the reference curve can be transferred from the unit to the host 40 values are always transferred at the same time After polling these first 40 values are transferred Once the host has confirmed receipt with lt ACK gt the next 40 values are transferred This continues until all values have been transferred When all values have been transferred the unit answers with lt EOT gt following the lt ACK gt Full 40 value containing blocks are always transferred The last block of 40 is padded with dummies There may be up to 4000 values Thus there may be up to 100 blocks The host must previously have retrieved the number of values using the RANZ command Host sends lt Address gt sr lt STX gt RYTR lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sen
105. indow entry can be defined The exit is always on the right for an Online window no matter how the setup is done For the block window type the exit is not relevant This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt FAUS P1 P2 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Window number 1 3 P2 Side of exit LINKS gt Exit to left RECHTS Exit to right OBEN gt Exit to top UNTEN gt Exit to bottom EGAL gt Exit side does not matter Readout of the present value With the command FAUS the side set for window exit can be read out Host sends lt Address gt sr lt STX gt FAUS P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P2 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Window number 1 3 P2 Side of exit LINKS gt Exit to left RECHTS gt Exit to right OBEN gt Exit to top UNTEN gt Exit to bottom EGAL gt Exit side does not matter 102 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 7 2 Switch points 3 3 7 2 1 SCHA Switch point 1 Input of a new value With the command SCHA the first Online swit
106. info command Host sends lt EOT gt The host controller unaddresses the device in order to start a polling sequence immediately Host sends 00po lt ENQ gt The 9310 with address 0 is requested to send all existing responses 9310 answers lt STX gt V200101 lt NUL gt SN123456 lt NUL gt 09 03 2001 lt NUL gt lt LF gt lt ETX gt This is the correct response to the info command Host sends lt ACK gt The controller has received the response and accepted it Does the 9310 have other queries saved for which a response can now be sent 9310 replies with lt EOT gt No This ends the communication sequence and the 9310 has unaddressed itself 15 BA_9310 Vxxx0_EN_2015 03 05 doc 2 3 9 Qbasic sample Read out of the DIGIFROCE 9310 Info String Compiler Version Quick Basic 4 5 2 3 9 1 Communication with Selection with response burster C R NAKS CHR 21 REM ck ck Ck ck Sk ck KKK KKK KKK KK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KK KKK KKK KKK KKK ko Sk kv ko kv ko ko ko REM k k k REM 9310_1 bas Developped by MN Li KE REM Communication Prog language Qbasic 1 1 KN REM exe File created with QB 4 5 EA REM with selection with KA REM response date 13 03 2000 05 05 2003 REM example ask for ID string ae REM k k k REM kkkkxkxkxkxkxkxkxkxkxkxkxkxkxkxkxkxkxkkxkxkxkxkxkxkxkxkxkxkkxkxkxkxkxkxkxkxkxkxkkkxkxkxkxkxkxkxkxkxkkkxkxkxkxkxkxkxkxkxkkkxkxk xx xx REM 1 Definition of ASCII Control
107. ion or relinquishes its master status to a secondary station and assumes slave status to receive data A connection between two secondary stations is not allowed The control station monitors the connection continuously 2 3 1 Establishing a connection Before a connection is established the control station has master status and none of the secondary stations have slave status The connection can be established in two different ways 1 Selection with response In this case device addressing and command sending do not take place in the same communications step This method is useful when you want to send several commands to the same device and then retrieve the responses to these commands in one go See communication example at the end of this chapter or 2 Fast Selection In this case addressing is combined with the command This saves a communications step if you want to exchange data with several devices via RS485 see communications example at the end of this chapter When establishing a connection the control station can either 1 specify a slave station in order to set up a connection i e send a command to the addressed slave or 2 carry out polling to grant master status to a secondary station i e request a response to a previously sent command and hence assign the transmit right to the slave 10 BA_9310 Vxxx0_EN_2015 03 05 doc ad 2 3 2 Selection with response The control station sends a selectio
108. ion protocol oreet ret dete ate Erotic e Pagus tuer ca chase aspe pate aeaa 10 2 3 1 Establishing a connectlon ct tee e n bem eec be eiie 10 2 3 2 Selection with response sssssssssssssssssssseseseereernn eren a E nnn n nene T e seen einn 11 2 3 3 Fast Selections rite teh E etc ta ter wade RN ace at Cum oh aude ce 11 2 3 4 Polling o oni tnnt tet e ead uiuat ciun ree cafe Nea 12 2 3 5 D ata tr nsfer 5 Lea ee n ett oie udo i Tate cu utah et NN e 12 2 3 6 Terminating a Cohrnection 4 Itt eai I e i Ue e eins 12 2 3 7 Command SEELUCIEG eo temo ot e et d t 13 2 3 7 1 Commands without parameters ccccccceceeeeeeeeceeceeeeeeesecaeaeceeeeeseseceueaeeeeeeeeeteeaees 13 2 3 7 2 Commands with parameters sss enne nnns 13 2 3 7 3 Strukture of an answer on a aaaa command 0 ccceceeeeeecececeeeeeeeteceneaeeeeeeeeetenaees 13 2 3 8 Examples of the communication sequence ssssssssssseeeeeeeeeeen nene 14 2 3 8 1 Communication Selection with response sample sss 14 2 3 8 2 Communication with Fast Selection sample sse 15 2 3 9 GQbasic sample 2 ER tet ent dv t orte de tu tu tado 16 2 3 9 1 Communication with Selection with response sssssssssssseeeee 16 2 3 9 2 Communication with Fast Selection sss 18 2 3 10 Construction and fragmentation of Ethernet UDP frames sse 20 24
109. l is started Only then the calibration data is taken over During calculation the data is being checked If this check has a negative outcome the device sends a NAK and does not take over the calibration The command has no further parameters An envelope will be corrected with the new calibration value if available This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt DOHY lt ETX gt lt BCC gt DIGIFORCE anwers lt ACK gt Host sends lt EOT gt 83 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 4 Zero signal 3 3 4 1 XORG Originally zero signal X channel Readout of the present value With the command XORG the originally zero signal of channel X can be read out Host sends lt Address gt sr lt STX gt XORG lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning value P1 Zero signal channel X Float value 3 3 4 YORG Originally zero signal Y channel Readout of the present value With the command YORG the originally zero signal of channel Y can be read out Host sends Address sr STX YORG ETX sBCC DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX
110. l range DMS type ssssseeeemm 167 3 7 4 PIEY Setting of Y channel range Piezo type 168 3 7 5 SPEI Setting of the Y channel supply DMS type sseeeem e 169 3 7 6 POTB Adjustment of the potential connection for strain gauge supply 170 3 7 7 UINT Internal voltage values eene ene enne 171 3 7 8 ROHW A D converter and voltage values sese eme 172 3 7 9 Test of the PLC inputs and outputs essssssssssssseseeenenene eene nennen 173 3 7 9 1 SPSI Read the PLC inputs ssssssssssssssesseseeenene nene eterne 173 3 7 9 2 SPSO Set the PLC outputs a e aeaa ea ar a raaa aaee raaa aa a a E aaa a nnne 173 3 7 10 ALED Test of the warning LED v oe ireira AEEA aE KE E nennen nemen 174 3 7 11 RESE Test of the RESET BUON ioiei iro e A E nennen nnne nnns 174 BA_9310 Vxxx0_EN_2015 03 05 doc had 1 Revision History Status description 28 02 2007 KS EthernetUDP protocol included 18 08 2006 KS envelope commands inserted 2 chapter Seral communication inserted chapter Testmode inserted new commands to manage the ethernet interface inserted BA_9310 Vxxx0_EN_2015 03 05 doc e 2 Serial communication The PC Software Digicontrol 9310 for device configuration backup and data recording is available Ordering code 9310 P10x The software is available in two versions The P101 version is for device configuration
111. lock of 20 is padded with dummies There may be up to 4000 values Thus there may be up to 200 blocks The host must previously have retrieved the number of values using the RANZ command Host sends lt Address gt sr lt STX gt R YSU lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P20 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt STX gt P21 P22 P23 P40 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 P4000 Y cumulative values of the Hex values without 0 reference curve termination 135 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 10 3 8 RXWE X values of the reference curve RXWE Values from host to unit With this command the X values normalized values values corrected by the zero point of the reference curve can be transferred from the host to the unit The X values are transferred in blocks of up to 20 values parameters 2 to 21 Parameter 1 is the block number With a maximum of 4000 values there is thus a maximum of 200 blocks The block number therefore gives the number of blocks which each contain 20 values Full 20 value containing blocks must always be transferred However the unit only considers values up until the number of values has been reached In the last block any of the 20 values which remain unfilled ca
112. lt BCC gt lt ACK gt lt EOT gt Parameter Meaning Value P1 Input range Readout of the present value 5V gt SV input range 7 LOV 10V input range With the command XNOR the present channel setting of the X channel resp standard signal can be read out Host sends DIGIFORCE answers Host sends Host sends DIGIFORCE answers Host sends DIGIFORCE answers Meaning of parameter Pn lt Address gt sr lt STX gt XNOR lt ETX gt lt BCC gt lt ACK gt lt EOT gt lt Address gt po lt ENQ gt lt STX gt P1 P2 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Parameter Meaning Value P1 Potentiometer yes or no 1 gt Potentiometer 0 gt no Potentiometer but standard signal Parameter Meaning Value P2 Input range 5V gt SV input range 7 10V 10V input range 69 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 3 5 YNOR Channel setting Y standard signal Input of a new value With the command YNOR the sensor channel Y can be set to standard signal This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt YNOR lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Readout of the present value With the command YNOR the present channel setting of the Y channel resp standard signal can be read out Host sends lt Address gt sr lt STX gt YNOR lt ETX gt
113. lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning value P1 X channel 0 gt X channel not in overrange overrange 1 gt X channel in overrange P2 Y channel 0 gt Y channel not in overrange overrange 1 gt Y channel in overrange 107 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 9 1 3 AKRV General curve data With the command AKRV the general curve data can be read out There are two ways to read out the curve data first of all all general curve data can be requested at once secondly the general curve data can be requested separately Readout of general curve data Here the command AKRV is called without parameter Host sends DIGIFORCE answers Host sends Host sends DIGIFORCE answers Host sends DIGIFORCE answers Meaning of parameter Pn lt Address gt sr lt STX gt AKRV lt ETX gt lt BCC gt lt ACK gt lt EOT gt lt Address gt po lt ENQ gt lt STX gt P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Parameter Meaning Value P1 Smallest force X coordinate Floating point number with unit P2 Smallest force Y coordinate Floating point number with unit P3 Greatest force X coordinate Floating point number with unit P4 Greatest force Y coordinate Floating point number with unit P5 Smallest displacement X coordinate Floating poin
114. lues are transferred as a difference from the preceding value The difference values are transferred in blocks of up to 20 values parameters 2 to 21 Parameter 1 is the block number With a maximum of 4000 values there is thus a maximum of 200 blocks The block number therefore gives the number of blocks which each contain 20 values Full 20 value containing blocks must always be transferred However the unit only considers values up until the number of values has been reached In the last block any of the 20 values which remain unfilled can be padded with dummies The number of values must therefore be transferred prior to this command using the command RANZ Host sends lt Address gt sr lt STX gt KXWE P1 P2 P21 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Block number Integer value 1 to 200 P2 P21 X difference values of the reference Hex values without 0 curve termination 149 BA_9310 Vxxx0_EN_2015 03 05 doc lian KXWE Transfer values from unit to host in an optimized manner With this command the X values normalized values only corrected by the zero point without taking into account the gradient of the reference curve can be transferred from the unit to the host in a time optimized manner The first value is transferred as an absolute value all other values are transferred as a difference from the preceding value If more that two sequential differenc
115. mand TCNT the NOK counter of the trend limit can be set Host sends lt Address gt sr lt STX gt TCNT P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Trend limit violated NOK counter Readout of present value With the command TCNT the NOK counter of the trend limit can be read out The command is only valid if the envelope is active Host sends lt Address gt sr lt STX gt TCNT lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Trend limit violated NOK counter 118 BA_9310 Vxxx0_EN_2015 03 05 doc With the HSTX command the envelope NOK statistic can be queried This relates to the NOK fraction in percent of the envelope relative to the total NOK evaluations 3 3 10 1 4 HSTX Envelope NOK statistic Host sends lt Address gt sr lt STX gt HSTX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter P1 NOK percentage of the envelope Positive integer with sign 3 3 10 1 5 HNIO Envelope NOK X Y Coordinate With the HNIO command
116. me number as received Status 0 OK NAK not used Timeout on serial interface STX not identified Identifier not valid ETX not identified Checksum error no answer unknown error measurement active illegal Host IP address static Not coded message received Not guilty key number Device is blocked by another master MAST command No fragmentation or count of the first fragmentation 20 identity number of fragmentation Data User data in ASCII format End sign ETX 0x03 or ENQ 0x05 with fragmentation Block Check 1 Byte Checksum all Bytes after STX including ETX ENQ are XOR combined Omocou doo ocomsomNwza2 Number 20 No fragmentation necessary data packet lt 7500 Byte lt STX gt Key Identifier Status 0 Data lt ETX gt lt Block Check gt Number 0 means no fragmentation End sign is ETX no fragmentation With fragmentation example data packet 18000 Byte 1st fragment lt STX gt Key Identifier Status 0 Data 1 7500 lt ENQ gt lt Block Check gt 2nd fragment lt STX gt Key Identifier Status 1 Data 7501 15000 lt ENQ gt lt Block Check gt 3rd fragment lt STX gt Key Identifier Status 2 Data 1 7500 lt ETX gt lt Block Check gt UDP frame format from HOST to DIGIFORCE 9310 lt STX gt Key Identifier Data End Sign gt Block Check STX 0x02 Key 0 message is not coded 1 message is coded Identifier continuous number 1 999 ASCII Data User data in ASCII format
117. ment programs can be read out Host sends lt Address gt sr lt STX gt PRNR lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Measurement program number 0 7 56 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 1 2 PNAM Program name Input of a new value With the command PNAM the name for the present Measurement program can be given Choosing a name does not select a new Measurement program The same name could be given to multiple programs Host sends lt Address gt sr lt STX gt PNAM P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of paramter Pn Parameter Meaning Value P1 Measurement program name Character chain of max 12 figures Readout of the present value With the command PNAM the name of the present Measurement program can be read out Host sends lt Address gt sr lt STX gt PNAM lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of paramter Pn Parameter Meaning Value Measurement program name Char
118. meter Meaning Value P1 Reference value for sensor test Y Floating point numbers without unit 90 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 6 Setting of measurement function 3 3 6 1 MFKT Measurement function Input of a new value With the command MFKT the measurement function for the present program can be transferred Host sends lt Address gt sr lt STX gt MFKT P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Measurement function Y F X gt Meas funct y f x Y F XT gt Meas funct y ft Y F T gt Meas funct y f Readout of the present value With the command MFKT the present measurement function can be read out Host sends lt Address gt sr lt STX gt MFKT lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Measurement function Y F X gt Meas funct y f x Y F XT gt Meas funct y fx t Y F T gt Meas funct y fw 91 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 6 2 RAST Sampling rate Input of a new value With the command RAST the value for the sampling rate can be entered It needs to be decided if itis a
119. meter Pn Reducing factor Integer value between 1 and 20 Readout of present value With the MRED command the current reducing value can be queried Description see over for the form of the command Host sends lt Address gt sr lt STX gt MRED lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Reducing factor Integer value between 1 and 20 146 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 4 1 2 KURX optimized transfer of the X values of the measurement curve With the KURX the X values of the measurement curve can be read in a time optimized manner The measurements are transferred in hexadecimal format without 0 termination to save time The first value is transferred as an absolute value all other values are transferred as a difference from the preceding value If more that two sequential difference values are the same then these are no transferred individually but rather in the following form M lt factor gt lt difference value gt M is the marker that indicates that this is not a single difference value It is followed by a factor that indicates the number of sequential difference values that are the same The character separates factor and difference value It is followed by the difference value The p
120. n be padded with dummies The number of values must therefore be transferred prior to this command using the command RANZ Host sends lt Address gt sr lt STX gt RXWE P1 P2 P21 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Block number Integer value 1 to 200 P2 P21 X values of the reference curve Hex values without 0 termination RXWE Values from unit to host With this command the X values normalized values values corrected by the zero point of the reference curve can be transferred from the unit to the host 40 values are always transferred at the same time After polling these first 40 values are transferred Once the host has confirmed receipt with lt ACK gt the next 40 values are transferred This continues until all values have been transferred When all values have been transferred the unit answers with lt EOT gt following the lt ACK gt Full 40 value containing blocks are always transferred The last block of 40 is padded with dummies There may be up to 4000 values Thus there may be up to 100 blocks The host must previously have retrieved the number of values using the RANZ command Host sends lt Address gt sr lt STX gt RXWE lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P40 lt ETX gt lt BCC gt Host sends lt ACK gt DIG
121. n be read out Host sends lt Address gt sr lt STX gt SPSI lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Bitcoded PLC inputs Short value in hex 0 to 1F Bit number Signal name of the PLC input 0 AUTO 1 I PROG2 2 I PROG1 3 I PROGO 4 I STROBE 5 I SENSOR TEST 6 I RESET STAT 7 I TARA Y 8 I START 3 7 9 2 SPSO Set the PLC outputs This command is only vaild if the Test mode is active With the command SPSO the twelve PLC outputs can be read out Host sends lt Address gt sr lt STX gt SPSO P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Bitcoded PLC outputs Short value in hex 0 to FFF O MESS AKTIV Bit number Signal name of the PLC input O PROG2 O PROG1 O PROGO O STROBE O IO S TEST O S2 O S1 O NIO ONL O NIO O IO 2J d o 14Ooj O1 AI IVIN o o O READY 173 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 7 10 ALED Test of the warning LED This command is only vaild if the Test mode is active Input of a new value With the command ALED the w
122. n channel Y can be read out Host sends lt Address gt sr lt STX gt FILY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Critical frequency of the Y channel AUS gt Filter off filter 5Hz gt Filter with fy 5Hz 10Hz gt Filter with f jZ10Hz 25Hz gt Filter with fg 25Hz 50Hz gt Filter with f j 50Hz 100Hz gt Filter with fy 100Hz 200Hz gt Filter with fy 200Hz 400Hz gt Filter with fg 400Hz 75 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 3 11 INVX Inverting X channel Input of a new value With the command INVX the inverting of the X channel can be switched on and off If the device is readjusted or if the adjustment values are loaded from the EEPROM the inverting is switched off automatically This is valid also for a default adjustment in case of loss of memory This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt INVX P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Inverting X channel 1 gt Inverting switched on 0 gt Inverting switched off Readout of the present value With t
123. n nnn nennen PBUE PROFIBUS Control scene nnne eene nn nne nennen PRIN Digital Inputs seo o dre E E E E C RR RE DRE ERR RED NRR PMEM Einstellen der Messmen Anwahl bei Profibusverkehr ecdg e ERN 3 2 8 1 RSET Otart Reset one t atv e e e Toe E de Drev De ede de eee dus Block Meas temlent uter ecosistema od s 0 2 REDY Release READY Signal eeceeeeseieeee netten ettet ee Administration of Measurement programs sssesseeeeeneeeme nennen Lsd 1 2 LIES DEFA Default Initializing of all Measurement programs eene DEFP Default Initializing of discrete Measurement programs ssss CMPR Copy a Measurement program sssssseeeeeneeene eene OK NOK graphical display esee eene nennen nnne nnns 2 1 INGR Selection OK NOK graphical display Choose Measurement men sreci a E A a e Ea a a 3 i MENU Choose Measurement menu ccccccceeeeccsseeceseseeecessaeeeceesauueeeeeeeseesaueeeeeeanes EIBH ETSO ETE 4 1 UPDA Control LCD update sihes nedi a e i iaai eaaa ei aade iaaii snnt nnn B rster Logo activation c n et da a A ae 3 2 15 1 LOGO Burser EOgo xen Ice T A N AN 3 9 Program specific SetU De rini anode a Sae Eaa a aa E aaa E a aaea General programm settings ssssssssssseneeeee eene ennemis
124. n supervisory sequence The selection supervisory sequence is used to initialize the 9310 as a slave so that it is subsequently possible to send commands to it The prefix calls up a single secondary station lt ENQ gt defines the end of the selection supervisory sequence The selection supervisory sequence of the 9310 has the following format lt Address gt sr lt ENQ gt e lt Address gt device address decimally 0 99 e Sr ASCII string s und r lt ENQ gt ASCII code ENQ A secondary station that recognizes its selection supervisory sequence assumes slave status and sends one of two responses 1 If the station is ready to receive data it sends lt ACK gt On receiving this response the master station initiates data transfer 2 If the station is not ready to receive data it sends lt NAK gt On receiving this response the master station can attempt call up the same station again If the master station receives an invalid response or none at all it can attempt to address the same station again or end the transmission 2 3 3 Fast Selection Instead of selection with response the master station can send a selection supervisory sequence without lt ENQ gt This will designate a secondary station as the slave station It then initiates data transfer directly without waiting for the acknowledge response from the secondary station The fast selection supervisory sequence of the 9310 has the following format lt Addre
125. nC 5 gt 50nC 6 gt 100 nC 7 gt 200 nC 8 gt 400 nC Readout of present value With the command PIEY the current Y channel range of the Piezo amplifier can be read out Host sends lt Address gt sr lt STX gt PIEY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 Y channel range Piezo type 1 nC range 2 nC 5 nC 10 nC 20 nC 50 nC 100 nC 200 nC 400 nC 0 100 amp QN oO VVVVVVNNN 168 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 7 5 SPEI Setting of the Y channel supply DMS type This command is only vaild if the Test mode is active Input of a new value With the command SPEI the Y channel supply can be set for test reason Host sends lt Address gt sr lt STX gt SPEI P1 lt ETX gt lt BCC gt DIGIFORCE answers ACK Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Y channel supply DMS type 0 gt 2 5V 1 gt 5V Readout of present value With the command SPEI the current Y channel supply can be read out Host sends lt Address gt sr lt STX gt SPEI lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 l
126. nd MERG the short form of the evaluation result can be read out If no measurement is present pieces counter 0 the device answers with the respective counter number but gives out a NOK signal If one input channel is overdriven the evaluation result is NOK see OVER command This input is valid only for the present measurement program Host sends DIGIFORCE answers Host sends Host sends DIGIFORCE answers Host sends DIGIFORCE answers Meaning of parameter Pn lt Address gt sr lt STX gt MERG lt ETX gt lt BCC gt lt ACK gt lt EOT gt lt Address gt po lt ENQ gt lt STX gt P1 P2 P3 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Parameter Meaning Value P1 Pieces counter 0 27 P2 NOK counter 0 27 P3 Total result NOK gt Evaluation result not as per specs OK gt Evaluation result in good order NOT gt Evaluation result NOK as result of passing the trend limiting with actice clinch point monitoring 106 BA_9310 Vxxx0_EN_2015 03 05 doc Ww 3 3 9 4 OVER Overrange of channel X Y With the command OVER The overrange status of both channel can be read out If one of the channel is in overrange the evaluation of the vurve is set NOK Host sends lt Address gt sr lt STX gt OVER lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3
127. nds DIGIFORCE answers Host sends Host sends DIGIFORCE answers Host sends DIGIFORCE answers Meaning of parameter Pn lt Address gt sr lt STX gt LCDK lt ETX gt lt BCC gt lt ACK gt lt EOT gt lt Address gt po lt ENQ gt lt STX gt P1 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Parameter P1 Meaning LCD contrast Value Number from 0 min to 10 max 34 BA_9310 Vxxx0_EN_2015 03 05 doc Me 3 2 4 Menu language 3 2 4 1 SPRA Menu language Input of a new value With the command SPRA a new menu language can be chosen Host sends lt Address gt sr lt STX gt SPRA P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Menu language DEUTSCH gt Menu language German ENGLISCH gt Menu language English FRANZOESISCH Menu language French Readout of the present value With the command SPRA the present menu language can be read out Host sends lt Address gt sr lt STX gt SPRA lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Menu language DEUTSCH gt Menu language German ENGLISCH g
128. no restriction active Host sends lt Address gt sr lt STX gt HOST P1 P2 P3 P4 P5 P6 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter meaning value P1 IP 1 access restriction 0 gt access not possible 1 gt access possible P2 Host IP address 1 Long 32 Bit HEXFORMAT P3 IP 2 access restriction 0 gt access not possible 1 gt access possible P4 Host IP address 2 Long 32 Bit HEXFORMAT P5 IP 3 access restriction 0 gt access not possible 1 gt access possible P6 Host IP address 3 Long 32 Bit HEXFORMAT Readout of the present value With the command HOST The status of the Host IP restriction can be read out Host sends lt Address gt sr lt STX gt HOST lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P4 P5 P6 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter meaning value P1 IP 1 access restriction 0 gt access not possible 1 gt access possible P2 Host IP address 1 Long 32 Bit HEXFORMAT P3 IP 2 access restriction 0 gt access not possible 1 gt access possible P4 Host IP address 2 Long 32 Bit HEXFORMAT P5 IP 3 access restriction 0 gt access not possible 1 gt access possible P6 Host IP address 3 Long 32
129. nterface commands 3 1 Comman Comands 3 1 1 Default Calibration 3 1 1 1 LGRK Load default calibration With the command LGRK the default calibration from EEPROM is loaded into the 9310 buffered RAM Host sends lt Address gt sr lt STX gt LGRK lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt 24 BA_9310 Vxxx0_EN_2015 03 05 doc Me 3 1 2 Informationen for PC software DIGICONTROL 3 1 2 1 DIGI DIGICONTROL specific device properties With the command DIGI the host can read out specific information about the device software Host sends lt Address gt sr lt STX gt DIGI lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE antswers lt STX gt P1 P2 P3 P3 P5 P6 P7 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Version of the sensor hardware Bito 0 DMS standard BitO 1 Piezo hex unsigned short P2 Version of the communikation 0x0 standard RS232 485 hardware BitO0 1 PROFIBUS available Bit1 0 RS485 Bit1 1 Ethernet Bit2 0 display device Bit2 1 Blackbox unsigned short P3 Counter an software changes with On every change of the 9310 influence on serial communication software with influence on serial communication this value is incremented The value starts on version V200208 with 0 decimally unsigned
130. o the unit The delta Y maximum values are transferred in blocks of up to 20 values parameters 2 to 21 Parameter 1 is the block number With a maximum of 4000 values there is thus a maximum of 200 blocks The block number therefore gives the number of blocks which each contain 20 values Full 20 value containing blocks must always be transferred However the unit only considers values up until the number of values has been reached In the last block any of the 20 values which remain unfilled can be padded with dummies The number of values must therefore be transferred prior to this command using the command RANZ Host sends lt Address gt sr lt STX gt RYMA P1 P2 P21 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Block number Integer value 1 to 200 P2 P21 Delta Y maximum values of the reference Hex values without 0 curve termination RYMA Values from unit to host With this command the delta Y maximum values of the reference curve are transferred from the unit to the host 40 values are always transferred at the same time After polling these first 40 values are transferred Once the host has confirmed receipt with lt ACK gt the next 40 values are transferred This continues until all values have been transferred When all values have been transferred the unit answers with lt EOT gt following the lt ACK gt Full 40 value containing blocks are always transferred
131. ocks of up to 20 values parameters 2 to 21 Parameter 1 is the block number With a maximum of 4000 values there 1s thus a maximum of 200 blocks The block number therefore gives the number of blocks which each contain 20 values Full 20 value containing blocks must always be transferred However the unit only considers values up until the number of values has been reached In the last block any of the 20 values which remain unfilled can be padded with dummies The number of values must therefore be transferred prior to this command using the command RANZ Host sends lt Address gt sr lt STX gt RYSU P1 P2 P21 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Meaning Block number Integer value 1 to 200 P2 P21 Y cumulative values of the Hex values without 0 reference curve termination RYSU Values from unit to host With this command the average Y values normalized values values corrected by the zero point of the reference curve can be transferred from the unit to the host 20 values are always transferred at the same time After polling these first 20 values are transferred Once the host has confirmed receipt with lt ACK gt the next 20 values are transferred This continues until all values have been transferred When all values have been transferred the unit answers with lt EOT gt following the lt ACK gt Full 20 value blocks are always transferred The last b
132. oint numbers with unit e g 1 234N Readout of the present value With the command TRGP the present trigger point can be read out Host sends lt Address gt sr lt STX gt TRGP lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 trigger point Floating point numbers with unit e g 1 234N 94 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 6 5 UKPT Turning Point Input of a new value With the command UKPT the turning point can be defined Up to this point the curve is displayed and evaluated This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt UKPT P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Turning point XMAX gt Turning point at maximum displacement YMAX gt Turning point at maximum force Readout of the present value With the command UKPT the present turning point can be read out Host sends lt Address gt sr lt STX gt UKPT lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt
133. on for this channel has been calculated DOKX DOKY This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt KALY P1 P2 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 lower calibration value Y channel Floating point number P2 upper calibration value Y channel Floating point number Readout of the present value With the command KALY the present calibration values can be read out Host sends lt Address gt sr lt STX gt KALY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 lower calibration value Y channel Floating point number P2 upper calibration value Y channel Floating point number 81 BA_9310 Vxxx0_EN_2015 03 05 doc Ww 3 3 3 17 MKLX Measure calibration value X channel With the command MKLX the calibration values for the X channel can be measured It must be indicated which calibration value is to be measured The entered values however are only taken over after a new calibration for this channel has been calculated DOKX DOKY This input is valid only for the present measurement program Host sends
134. ope can be reset to its teach in value when trend tracking is switched on The command is only valid if the clinch function is switched on Host sends lt Address gt sr lt STX gt RESH lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt No parameter no query form 128 BA_9310 Vxxx0_EN_2015 03 05 doc Ww 3 3 10 3 Envelope setup 3 3 10 3 1 HEIN Setup envelope new modify Input of a new value With the HEIN command the operating mode for setting up the envelope can be set new modify Host sends lt Address gt sr lt STX gt HEIN P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn P1 Type of envelope setup NEW gt new envelope is set up MODIFY gt envelope is modified Readout of present value With the HEIN command the operating mode for setting up the envelope can be queried new modify Host sends lt Address gt sr lt STX gt HEIN lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 Type of envelope setup NEW gt new envelope is set up MODIFY gt envelope is modified 129 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 10 3 2 HEBE Type of confirmation when setting up the envelope always once Input of a ne
135. or test X can be read out Host sends lt Address gt sr lt STX gt STTX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Tolerance value for sensor test X Floating point numbers without unit 87 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 5 4 STTY Tolerance sensor test Y Input of a new value With the command STTX the tolerance value for sensor test X can be entered The value is given in the present X unit This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt STTY P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Tolerance value for sensor test Y Floating point numbers without unit Readout of the present value With the command STTY the present tolerance value for sensor test Y can be read out Host sends lt Address gt sr lt STX gt STTY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Par
136. or the sensor test Y During the sensor test this value must be met within the indicated tolerances This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt SETY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Readout of the present value With the command SETY the presently measured sensor test value for Y channel can be read out Host sends lt Address gt sr lt STX gt SETY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 Value for sensor test Y Floating point number with unit e g 11 2345mm 86 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 5 3 STTX Tolerance sensor test X Input of a new value With the command STTX the tolerance value for sensor test X can be entered The value is given in the present X unit This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt STTX P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Tolerance value for sensor test X Floating point numbers without unit Readout of the present value With the command STTX the present tolerance value for sens
137. ost sends lt Address gt sr lt STX gt YPIE lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Input range 1NC gt Inputrange 1nC 2NC gt Inputrange 2nC 5NC gt Inputrange 5nC 10NC gt Input range 10nC 20NC gt Input range 20nC 50NC gt Input range 50 nC 100NC gt Input range 100 nC 200NC gt Input range 200 nC 400NC gt Input range 400 nC 72 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 3 8 PIKZ Short circuit for the Piezo amplifier close and open Input of a new value The command PIKZ is valid only for the piezo version of the DIGIFORCE PIKZ value 1 must be send to unload the charging amplifier and close the Piezo input after every measurement Before you START the next measurement you have to send the PIKZ command with the value 0 open Host sends lt Adress gt sr lt STX gt PIKZ P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Piezo input charging amplifier 1 gt closed 0 gt open only while the measurement is running Readout the present status of the charging amplifier open or close With the command PIKZ you can readout the pre
138. ost sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Window 1 NOK counter Window 2 NOK counter Window 3 NOK counter 111 BA_9310 Vxxx0_EN_2015 03 05 doc With the command FEAU the coordinates for window entry exit of any one window can be read out for the last measurement If no measurement has been effected pieces counter 0 the device answers with NAK 3 3 9 3 3 FEAU Window Entry Exit Host sends lt Address gt sr lt STX gt FEAU P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P2 P3 P4 P5 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Window number 14 3 P2 Window entry X coordinate Floating point number with unit P3 Window entry Y coordinate Floating point number with unit P4 Window exit X coordinate Floating point number with unit for block window block value X P5 Window exit Y coordinate Floating point number with unit for block window block value Y 112 BA_9310 Vxxx0_EN_2015 03 05 doc With the command FALL the summery of the single commands FERG FSTX and FEAU Can be read out with one command 3 3 9 2 4 FALL Re
139. ow entry Input of a new value With the command FEIN the side for window entry can be defined The entry for an Online window is always on the left side no matter how the setup is done This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt FEIN P1 P2 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Window number 1 3 P2 Side of entry LINKS gt Entry on left RECHTS gt Entry on right OBEN gt Entry on top UNTEN gt Entry on bottom EGAL Entry does not matter Readout of the present value With the command FEIN the side of entry to the window can be read out Host sends lt Address gt sr lt STX gt FEIN P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P2 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Window number 1 3 P2 Side of entry LINKS gt Entry on left RECHTS gt Entry on right OBEN gt Entry on top UNTEN gt Entry on bottom EGAL gt Entry side does not matter 101 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 7 1 4 FAUS Window exit Input of a new value With the command FAUS the side for w
140. r test X can be read out Host sends Address sr STX STWX ETX sBCC DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Reference value for sensor test X Floating point numbers without unit 89 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 5 7 STWY Reference value for sensor test channel Y Input of a new value With the command STW Y the reference value for the sensor test Y can be entered The value is given in the present X unit This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt STWY P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Reference value for sensor test Y Floating point numbers without unit Readout of the present value With the command STW X the present reference value for sensor test Y can be read out Host sends lt Address gt sr lt STX gt STWY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Para
141. recorded the NAK is returned and the bit 0x0400 is set in the error status register Host sends DIGIFORCE answers Host sends Host sends DIGIFORCE answers Host sends DIGIFORCE answers Meaning of parameter Pn lt Address gt sr lt STX gt FERG lt ETX gt lt BCC gt lt ACK gt lt EOT gt lt Address gt po lt ENQ gt lt STX gt P1 P2 P3 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Parameter Meaning Value P1 Result window 1 NOK Window was not in specs OK gt Window was in specs OFF gt Window was not activated P2 Result window 2 NOK gt Window was not in specs OK gt Window was in specs OFF Window was not activated P3 Result window 3 NOK gt Window was not in specs OK gt Window was in specs OFF gt Window was not activated 110 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 9 3 FCNT Window NOK counter Input of a new value With the command FCNT the window NOK counter can be set Host sends lt Address gt sr lt STX gt FCNT P1 P2 P3 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Window 1 NOK counter Window 2 NOK counter Window 3 NOK counter Readout of present value With the command FCNT the window NOK counter can be read out Host sends lt Address gt sr lt STX gt FCNT lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt H
142. resent READY Mode can be read out Host sends lt Address gt sr lt STX gt RDYM lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Ready Mode 0 gt READY Mode normal 1 gt READY Mode PC controlled 3 2 10 2 REDY Release READY Signal With the command REDY the READY Signal can be released This command makes sense only when the READY Mode PC controlled is active Host sends lt Address gt sr lt STX gt REDY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt 50 BA_9310 Vxxx0_EN_2015 03 05 doc 3 2 11 Administration of Measurement programs 3 2 11 1 DEFA Default Initializing of all Measurement programs With the command DEFA all seven Measurement programs are initialized with Default values All entries are erased Host sends DIGIFORCE answers lt ACK gt Host sends lt EOT gt lt Address gt sr lt STX gt DEFA lt ETX gt lt BCC gt 3 2 11 2 DEFP Default Initializing of discrete Measurement programs With the command DEFP a discrete Measurement program is initialized with es MeRprogramm mit Default Werten initialisiert Alle Eingaben in diesem Programm werden gel scht Host sends DIGIFORCE answers lt ACK gt Host
143. rrr tote Sand FE ER Saa E aE a cn nc Oaa A aa 103 3 3 8 During Meas tremont einen aaa E tet ee ien lad qe catt aid db uen aad qu 105 3 3 8 1 MSTA Status of Measurement sessi 105 3 3 9 Output of Measurement results sssssssssssssseseeeeneeee eene nennen nennen 106 3 3 9 1 SMOPE TORN ios essits TED ML E 106 3 3 9 2 WINdOW TESUITS ic 5 it reete ertt Phe eter ted ert enu eer t bete dosti ttawel t 110 3 3 9 3 SUAtiStiCS 2 oi eren edd ett eet oa Neen ute 114 3 3 9 4 Measurement CUrVe 2 enint Reo eot ie LR Hotte oes ud es 115 SES BI aho oe E 117 3 3 104 Eval ationres ult uote eem deceret ie decade ise RE 117 3 3 10 2 Configuration of the envelope sssssessseeeeene eene 122 3 3 10 3 Envelope Setup eR Eee o ER S CEREREM E HER RS RE 129 3 3 10 4 Selecting the display from the setup menu sssssee eee 141 3 3 41 Remaining blade thickness RBD Plate pack thickness BPD sssssss 145 3 4 Commands optimized in respect of transfer time eeeeseseseeeseeeee 146 3 4 1 Transfer of the measurement curve ccccceceeeseeeeeeeceeeeeeeeeeeeeeeceeeeeeseeeseseseseeeseseseeeeeeeses 146 3 4 1 1 MRED Gormirnand 2 2 tee eeu acd 146 3 4 1 2 KURX optimized transfer of the X values of the measurement curve 147 3 4 1 3 KURY optimized transfer of the Y values of the measurement curve
144. s gt sr lt STX gt STAR P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 PLC tare function X Only tare X is started Y Only tare Y is started X Y gt Tare X and Y are started Read out an already configured PLC tare function Host sends lt Address gt sr lt STX gt STAR lt ET X gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Valke P1 PLC tare function X Only tare X is started Y Only tare Y is started X Y Tare X and Y are started 3 3 6 9 TARA Start Function via interface With the command TARA the tare X or Y can be started via the serial interface Host sends lt Address gt sr lt STX gt TARA P1 P2 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Tare X or Y Xo Tare X Y gt Tare Y P2 Start or take back tare 1 Start tare function 0 Take back tare function 98 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 7 Evaluation 3 3 7 1 Window 3 3 7 1 1 FTYP Type of window Input of a new value With the command FT YP the type of evaluation window can be defined The input mak
145. s resp the position of the evaluation windows can be transferred The upper window borders have to be greater than the lower borders This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt FGRZ P1 P2 P3 P4 P5 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Window number 1 3 P2 Window border Xmin Floating point number without unit P2 Window border Xmax Floating point number without unit P2 Window border Ymin Floating point number without unit P2 Window border Ymax Floating point number without unit Readout of the present value With the command FGRZ the present window borders can be read out Host sends lt Address gt sr lt STX gt FGRZ P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P2 P3 P4 P5 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Window number 1 3 P2 Window border Xmin Floating point number without unit P2 Window border Xmax Floating point number without unit P2 Window border Ymin Floating point number without unit P2 Window border Ymax Floating point number without unit 100 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 7 4 5 FEIN Wind
146. s transferred then a LF is transferred After host acknowledgement with ACK the next 10 value pairs are transferred and so on Querying continues until there are no more available measurements If the last block has less than 10 difference values then transfer is terminated early If there are no more available values then an EOT is sent in response to the ACK acknowledgement There may be up to 4000 values Thus there may be up to 400 blocks The host must previously have retrieved the number of values using the RANZ command The host must calculate the absolute values from the difference values with the exception of the 1st value Absolute value n absolute value n 1 difference value n The transferred difference values and the absolute values calculated from them are normalized integer values 16 bit These values are used with the gradient values which are retrieved using the KRVA command to calculate the floating point values in their respective units Floating point value Normalized absolute value gradient Host sends lt Address gt sr lt STX gt K YSU lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P10 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt STX gt P11 P12 P13 P20 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parame
147. sent status open or close of the charging amplifier The command PIKZ is valid only for the piezo version of the DIGIFORCE Host sends lt Address gt sr lt STX gt PIKZ lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Piezo input charging amplifier 1 gt closed unloading 0 gt open only while the measurement is running 73 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 3 9 FILX Filter X Input of a new value With the command FILX the filter on the X channel can be activated This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt FILX P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Critical frequency of the X channel AUS gt Filter off filter 5Hz gt Filter with fy 5Hz 10Hz gt Filter with fg 10Hz 25Hz gt Filter with fg 25Hz 50Hz gt Filter with f j 50Hz 100Hz gt Filter with fy 100Hz 200Hz gt Filter with fy 200Hz 400Hz gt Filter with fy 400Hz Readout of the present value With the command FIL X the present settings for channel X can be read out Host sends lt Ad
148. ss gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter meaning value P1 DIGIFORCE error code Error code bit coded Error code Bit 6 5 4 3 Bit 7 0 N e to Nonvolatile data are cleared in RAM EEPROM can not be programmed Calibration data are cleared Hardware error Bit7 4 0 not used 164 BA_9310 Vxxx0_EN_2015 03 05 doc Ww 3 7 Testmode 3 7 1 TEST Testmode On Off Input of a new value With the command TEST the test mode can be switched on or off In normal operation the test mode have to be switched off To use the following test commands BERX DMSY PIEY SPEI POTB SPSO ALED you have to switch the test mode on While switching off the test mode the original device settings are available again Host sends lt Address gt sr lt STX gt TEST P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Testmode 1 gt set testmode on 0 gt set testmode off Readout of present value With the command TEST The current status of testmode can be read out Host sends lt Address gt sr lt STX gt TEST lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers
149. ss gt sr lt STX gt command lt ETX gt lt BCC gt lt ETX gt ASCII code ETX lt BCC gt optionally Blockcheck see Chapter 2 3 5 Daten bertragung e lt Address gt device address decimally 0 99 e Sr ASCII string s und r e lt STX gt ASCII code STX e Befehl command sequence e e 11 BA_9310 Vxxx0_EN_2015 03 05 doc e 2 3 4 Polling The control station sends a polling supervisory sequence The polling supervisory sequence is used to retrieve requested data from the 9310 The prefix selects a single station lt ENQ gt defines the end of the Polling supervisory sequence The Polling Supervisory Sequence of DIGIFORCE 9310 has the following structure lt Address gt po lt ENQ gt e Address hexadezimal device address 0 99 e po ASCII string p und o e lt ENQ gt ASCII code ENQ A secondary station that recognizes its polling supervisory sequence responds using one of two options 1 If the station has data ready to send it starts the data transfer The control station assumes slave status 2 If the station has no data ready to send it sends lt EOT gt which terminates its master status The master status returns to the control station If the control station receives an invalid response or none at all it terminates the connection by sending lt EOT gt 2 3 5 Data transfer After establishing the connection data is transferred in accordance with the rules of subcategory A4 The master st
150. ss than 20 difference values then transfer is terminated early If there are no more available values then an EOT is sent in response to the ACK acknowledgement There may be up to 4000 values Thus there may be up to 200 blocks The host must previously have retrieved the number of values using the RANZ command The host must calculate the absolute values from the difference values with the exception of the 1st value Absolute value n absolute value n 1 difference value n The transferred difference values and the absolute values calculated from them are normalized integer values 16 bit These values are used with the gradient values which are retrieved using the KRVA command to calculate the floating point values in their respective units Floating point value Normalized absolute value gradient Host sends lt Address gt sr lt STX gt K YTR lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P20 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt STX gt P21 P22 P23 P40 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 P4000 Y difference values of the reference Hex values without 0 curve termination 156 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 4 2 5 KYMI optimized transfer of the delta Y minimum values of the refer
151. t Menu language English FRANZOESISCH Menu language French 3 2 5 RS232 interface Settings of the RS232 interface cannot be done via the RS232 interface 35 BA_9310 Vxxx0_EN_2015 03 05 doc un 3 2 6 Ethernet Interface 3 2 6 1 IPEX IP address Gateway address subnet mask and UDP Port Input of a new value With the command IPEX IP address Gateway address subnet mask and UDP port can be set The settings are only valid if the srial number of the commad is the same as the device Host sends lt Address gt sr lt STX gt IPEX P1 P2 P3 P4 P5 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Serial number of the DIGIFORCE 9310 Figure chain with length 10 e g 1234567890 IP address Long 32 Bit HEXFORMAT Subnet mask Long 32 Bit HEXFORMAT Gateway address Long 32 Bit HEXFORMAT Integer 16bit decimally Readout of the present value With the command IPEX IP address Gateway address subnet mask and UDP port can be read out Host sends lt Address gt sr lt STX gt IPEX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE anwers lt STX gt P1 P2 P3 P4 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn IP Adaress Long 32 Bit HEXFORMAT Subnet mask Long 32 Bit HEXFOR
152. t P2 Upper display limit X Floating point number without unit P3 Lower display limit Y Floating point number without unit P4 Upper display limit Y Floating point number without unit 62 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 1 8 NIOA NOK display in percent absolute Input of a new value With the command NIOA the display of NOK measurements can be switched to show the absolute NOK quantity or the percentage of NOK parts in relation to the total number of measurements in the M4 measurement menu This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt NIOA P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 NOK display PROZ gt Display in percentage ABS _ gt Display in absolute figures Readout of the present value With the command NIOA the present status of the NOK display can be read out Host sends lt Address gt sr lt STX gt NIOA lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 NOK display PROZ 2 Display in percentage ABS gt Display in absolute figures 63 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 2
153. t Trend limit of the envelope has not been reached 1 gt Trend limit of the envelope has not been reached p window trend limit reached 0 Trend limit is not reached or online window is off 1 gt Trend limit of the online window has not been reached Block window trend limit reached 0 Trend limit has not been reached or block window is off 1 Trend limit of the block window has been reached 120 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 10 1 7 TSTX Trend limit reaches NOK statistic With the TSTX command the trend limit reached NOK statistic can be queried This relates to the NOK fraction in percent of the trend limit reached relative to the total NOK evaluations The trend limit reached statistic only functions if clinch function is activated and trend is switched on Host sends lt Address gt sr lt STX gt TSTX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 NOK percentage if trend limit reached Positive integer with sign 3 3 10 1 8 TNIO trend limit reached NOK X Y coordinate With the TNIO command the X Y coordinate can be retrieved at which in the NOK case the trend limit has been crossed The command is only valid if the envelope is activated clinch function is activated
154. t BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt 3 3 3 20 DOHX Execute calibration on X channel with envelope correction With the command DOHX a calculation of calibration data for the X channel is started Only then the calibration data is taken over During calculation the data is being checked If this check has a negative outcome the device sends a NAK and does not take over the calibration The command has no further parameters An envelope will be corrected with the new calibration value if available This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt DOHX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt 82 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 3 21 DOKY Execute calibration on Y channel With the command DOKY a calculation of calibration data for the Y channel is started Only then the calibration data is taken over During calculation the data is being checked If this check has a negative outcome the device sends a NAK and does not take over the calibration The command has no further parameters This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt DOKY lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt 3 3 3 22 DOHY Execute calibration on Y channel with envelope correction With the command DOHY a calculation of calibration data for the Y channe
155. t ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Y channel supply DMS type 0 gt 2 5 V 1 gt 5V 169 BA_9310 Vxxx0_EN_2015 03 05 doc len 3 7 6 POTB Adjustment of the potential connection for strain gauge supply This command is only vaild if the Test mode is active Input of a new value The potential connection of the strain gauge supply is set using the POTB command Host sends lt Address gt sr lt STX gt POTB P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Potential connection of strain gauge 0 gt internal supply 1 gt external source Readout of present value The potential connection of the DMS supply is retrieved using the POTB command Host sends lt Address gt sr lt STX gt POTB lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Potential connection of strain gauge 0 gt internal supply 1 gt external source 170 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 7 7 UINT Internal voltage values Readout of present value With the
156. t number with unit P6 Smallest displacement Y coordinate Floating point number with unit P7 Greatest displacement X coordinate Floating point number with unit P8 Greatest displacement Y coordinate Floating point number with unit P9 Last point X coordinate Floating point number with unit P10 Last point Y coordinate Floating point number with unit P11 First point X coordinate Floating point number with unit P12 First point Y coordinate Floating point number with unit Readout of single general curve data With the command AKRV the general curve data is read out with request parameters Host sends lt Address gt sr lt STX gt AKRV P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P2 P3 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning P1 Desired value Value YMIN gt Smallest force YMAX gt Greatest force XMIN gt Smallest displacement XMAX gt Greatest displacement LAST gt Last point FIRST gt First point Floating point number with unit Floating point number with unit P2 Requested value X coordinate P3 Requested value Y coordinate 108 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 9 1 4 MALL Common curve data With the command MALL a summery of all curve and evaluation res
157. tatus The command FSTA can read out the fault status on the serial interface The reason for the last transferred NAK might be indicated here The fault status is bit coded i e multiple bits can be set simultaneously Host sends lt Address gt sr lt STX gt FSTA lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 0x0001 PREFIX address error 0x0002 Enquiry received in Slave Mode 0x0004 Block check error 0x0008 Commando error 0x0010 Parameter Fehler 0x0020 Timeout Receive Timer 0x0040 Timeout Response Timer 0x0080 Unvalid or sign 0x0100 Unvalid configuration 0x0200 Scale error 0x0400 No valid measurement can be found 0x0800 A D changer overdriven 0x1000 EEPROM reading error during loading of basic calibration 0x2000 Overdriven by scaling Ox4000 The transfer of a measurement curve was cancelled by a start of a new measurement 0x8000 Unvalid envelope borders 163 BA_9310 Vxxx0_EN_2015 03 05 doc Ww 3 6 2 ERRO Read out of device error status Readout of present value With the command ERRO The DIGIFORCE error status can be read out Host sends lt Address gt sr lt STX gt ERRO lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Addre
158. ter Pn P1 P4000 Difference Y cumulative values of the Hex values without 0 reference curve termination 154 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 4 2 4 KYTR optimized transfer of the Y mean value values of the reference curve non tracked values If trend is activated this relates to the non tracked values KYTR Transfer values from host to unit in an optimized manner With this command the Y mean values normalized integer values values corrected by the zero point without taking into account the gradient of the reference curve can be transferred from the host to the unit The values are transferred in hexadecimal format without 0 termination to save time The first value is transferred as an absolute value all other values are transferred as a difference from the preceding value The difference values are transferred in blocks of up to 20 values parameters 2 to 21 Parameter 1 is the block number With a maximum of 4000 values there is thus a maximum of 200 blocks The block number therefore gives the number of blocks which each contain 20 values Full 20 value containing blocks must always be transferred However the unit only considers values up until the number of values has been reached In the last block any of the 20 values which remain unfilled can be padded with dummies The number of values must therefore be transferred prior to this command using the command RANZ Host sends lt Address gt sr lt STX gt KY
159. the X Y coordinate can be retrieved at which in the NOK case the envelope has been crossed The command is only valid if the envelope is activated Host sends lt Address gt sr lt STX gt HNIO lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 X coordinate of the point where the envelope has Floating point number been crossed with X unit P2 Y coordinate of the point where the envelope has Floating point number been crossed with Y unit 119 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 10 1 6 TGRZ Trend limit reached With the TGRZ command the result of trend tracking can be retrieved Has the trend limit been reached and where Through the envelope the online window or the block window The command in only allowed if trend tracking is activated If the online or the block window is off then a 0 is returned Host sends lt Address gt sr lt STX gt TGRZ lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn parameter Meaning Value Ere fee trend limit reached 0 g
160. tion result of the envelope can be read out Host sends lt Address gt sr lt STX gt HERG lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn P1 Envelope evaluation result NOK gt envelope was violated OK 2 data within envelope curve band OFF gt envelope not active 3 3 10 1 2 HCNT Envelope NOK counter Input of a new value With the command HCNT the NOK counter of the envelope evaluation can be set Host sends lt Address gt sr lt STX gt HCNT P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Envelope NOK counter Readout of present value With the command HCNT the NOK counter of the envelope evaluation can be read out The command is only valid if the envelope is active Host sends lt Address gt sr lt STX gt HCNT lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Envelope NOK counter 117 BA_9310 Vxxx0_EN_2015 03 05 doc fen 3 3 10 1 3 TCNT Ternd limit violated NOK counter Input of a new value With the com
161. transferred from the host to the unit The values are transferred in hexadecimal format without 0 termination to save time The first value is transferred as an absolute value all other values are transferred as a difference from the preceding value The difference values are transferred in blocks of up to 20 values parameters 2 to 21 Parameter 1 is the block number With a maximum of 4000 values there is thus a maximum of 200 blocks The block number therefore gives the number of blocks which each contain 20 values Full 20 value containing blocks must always be transferred However the unit only considers values up until the number of values has been reached In the last block any of the 20 values which remain unfilled can be padded with dummies The number of values must therefore be transferred prior to this command using the command RANZ Host sends lt Address gt sr lt STX gt K YMA P1 P2 P21 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Block number Integer value 1 to 200 P2 P21 Difference values of the delta Y maximum values of the Hex values without 0 reference curve termination 159 BA_9310 Vxxx0_EN_2015 03 05 doc lian KYMA Transfer values from unit to host in an optimized manner With this command the maximum Y values normalized integer values values corrected by the zero point without taking into account the
162. ues X Input of a new value With the command KALX the calibration values for the X channel can be transferred The entered values however are only taken over after a new calibration for this channel has been calculated DOKX DOKY This input is valid only for the present measurement program Host sends lt Address gt sr lt STX gt KALX P1 P2 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 lower calibration value X channel Floating point number P2 upper calibration value X channel Floating point number Readout of the present value With the command KALX the present calibration values can be read out Host sends lt Address gt sr lt STX gt KALX lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 lower calibration value X channel Floating point number P2 upper calibration value X channel Floating point number 80 BA_9310 Vxxx0_EN_2015 03 05 doc lian 3 3 3 16 KALY Calibration values Y Input of a new value With the command KALY the calibration values for the Y channel can be transferred The entered values however are only taken over after a new calibrati
163. ults can be read out Single parts can be ead with the commands MERG AKRV and KRVA Host sends lt Address gt sr lt STX gt MALL lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 P2 P3 P25 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Parameter Meaning jvaue Unit X Axis Character chain with 4 figures MX axis zero point of X values float m maon o oO Pe KY axis gradient of Y values float P8 Pieces counter 0 2 P9 NOK counter P10 Total result NOK gt Evaluation result not as per specs OK gt Evaluation result in good order NOT gt Evaluation result NOK as result of passing the trend limiting with actice clinch point monitoring 1 gt X channel in overrange ME channel overrange 0 gt Y channel noti in overrange Ms 0 gt Max number of values not reached max number of values reached 1 gt Max number of values is reached 109 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 9 2 Window results 3 3 9 2 1 FERG Window result With the command FERG the results of the single windows can be requested The data refers to the last measurement If no measurement has been done since last reset then all active windows are displayed with NOK result If no measurement values have been
164. ute TRIG gt Reference Trigger Only channel X and if Trigger is active 104 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 8 During Measurement 3 3 8 1 MSTA Status of Measurement With the command MSTA the present Measurement status can be read out This input is valid only for the present measurement program Host sends DIGIFORCE answers Host sends Host sends DIGIFORCE answers Host sends DIGIFORCE answers Meaning of parameter Pn lt Address gt sr lt STX gt MSTA lt ETX gt lt BCC gt lt ACK gt lt EOT gt lt Address gt po lt ENQ gt lt STX gt P1 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Parameter P1 Meaning Value Status of 0 gt Since last reset no measurement was started Measurement 1 gt Present measurement results have been read out 2 gt Present measurement no results have yet been read out 105 BA_9310 Vxxx0_EN_2015 03 05 doc 3 3 9 Output of Measurement results 3 3 9 1 Short form 3 3 9 1 1 MERG Measurement result Input of a new value With the command MERG The pieces counter and NOK counter can be set for backup Host sends DIGIFORCE answers Host sends Meaning of parameter Pn lt Address gt sr lt STX gt MERG P1 P2 lt ETX gt lt BCC gt lt ACK gt lt EOT gt Parameter Meaing Value P1 Pieces counter 0 2 P2 NOK counter 0 27 Readout of present value With the comma
165. w value With the HEBE command the confirmation when setting up the envelope can be set once always Host sends lt Address gt sr lt STX gt HEBE P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Confirmation type when setting up the ALWAYS gt Confirm after each curve envelope ONCE gt confirm once at end Readout of present value With the HEBE command the confirmation when setting up the envelope can be queried once always Host sends lt Address gt sr lt STX gt HEBE lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn Value P1 Confirmation type when setting up the ALWAYS gt Confirm after each curve envelope ONCE gt confirm once at end 130 BA_9310 Vxxx0_EN_2015 03 05 doc ian 3 3 10 3 3 HARE number of reference curves when setting up the envelope Input of a new value With the HARE command the number of reference curves used when setting up the envelope can be set Host sends lt Address gt sr lt STX gt HARE P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Number of reference curves when setting up the envelope Valid
166. with other hosts Host sends lt Address gt sr lt STX gt MAST P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn P1 Time units in 100ms to reserve the 9310 0 gt device not reserved 20 gt time units in 100ms unsigned long e g a value of 10 reserve the device 1 second Note Within the running time the host have to send a new MAST command to ensure that the device is blocked for other hosts 43 BA_9310 Vxxx0_EN_2015 03 05 doc um 3 2 7 PROFIBUS interface 3 2 7 1 PBAD PROFIBUS address This command only exists in the instrument if the option PROFIBUS DP is installed If this is not the case the request will be answered by NAK Input of a new value With the command PBAD the new PROFIBUS address can be entered Host sends lt Address gt sr lt STX gt PBAD P1 lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Meaning of parameter Pn Parameter Meaning Value P1 Address for PROFIBUS interface 0 127 Readout of present value With the command PBAD the present PROFIBUS address can be read out Host sends lt Address gt sr lt S TX gt PBAD lt ETX gt lt BCC gt DIGIFORCE answers lt ACK gt Host sends lt EOT gt Host sends lt Address gt po lt ENQ gt DIGIFORCE answers lt STX gt P1 lt ETX gt lt BCC gt Host sends lt ACK gt DIGIFORCE answers lt EOT gt Meaning of parameter Pn
167. zo sensor sssssssseeeeenm eene PIKZ Short circuit for the Piezo amplifier close and open ssesssss ETEK FROT A ie esset hesouniteuneaneimte mue PREY OEHOE Y i meth th CO e Ret E Et RR ORT E ERR se ith INVX Inverting X channel ssssessseseeeeeneen menn mene nemen nnne nnns INVY Inverting Y Channel ccccceseeenceteeeeneesseceneeteneeeeesseeeneeteeeentesseneneeteeeennes SKAX SCalarvalues X ron i re E e E REPRE p UH d ns BA_9310 Vxxx0_EN_2015 03 05 doc uu SoOed3qeL4 SKAY Scalarvalule 4 ici et et c e d tht 79 323632155 KALX Galibration Values X niet en ta dno eer feet 80 3 3 3 16 KALY Calibration values Y esee een 81 3 3 3 17 MKLX Measure calibration value X channel essen 82 3 3 3 18 MKLY Measure calibration value Y channel eeeeeseseeeeeeees 82 3 3 3 19 DOKX Execute calibration on X channel eese 82 3 3 3 20 DOHX Execute calibration on X channel with envelope correction 82 3 3 3 21 DOKY Execute calibration on Y channel eese 83 3 3 3 22 DOHY Execute calibration on Y channel with envelope correction 83 3 3 4 Zero sighal eei ID eaves othe a ee Geant MD dd 84 3 3 4 1 XORG Originally zero signal X channel essseene emen 84 3 3 4 2 YORG Originally zero signal Y

Download Pdf Manuals

image

Related Search

Related Contents

Notice - Factorydirect  XScan 3  HP External USB DVD RW Drive  Execução Física  La série d`huiles moteur pour les poids lourds pour une  Samsung MAX-L47 Manual de Usuario  Grafiprint laminates LAMGLOW - grafityp selfadhesive products  Gisowatt 60008BYI  Bedienungsanleitung Mode d`emploi Istruzioni per l`uso Operating  印刷用(PDF) - アライドテレシス  