Home

Power Outlet User Manual

image

Contents

1. B board e Do not use any strong chemical or washing to cleanse the device e Do not use any coloring materials on any removable parts which my cause poor connections and may keep the device from function properly All the above applies to the purchased products battery and other packaged items If any unusable or damaged items are found please return the product to your nearest authorized repairing center Important Notice Under any circumstances without Netvox written approval copy or redistribute any parts of this document is strongly prohibited Netvox adhere to product development policy and therefore reserve the right to change and or add contents to this document without any further notice Under any circumstances or matters Netvox is not responsible for data or revenue loss or any indirect additional loss that may arise from special cases or any sudden obligations This documentation is provided according to the product at the time of purchase Netvox do not inherent any responsibility and promise or guarantee of the reliability of the document contents this applies but not limited to market piloting or real use case purposes or otherwise it is legally stated Netvox reserve the right to change and or add contents to this document without any further notice
2. devices to the network This is particularly useful when coordinator is not within the coverage area By default the router does not allow permit to join function in normal operation You would need to enable this feature by simply hold press the binding key on Z805 the indicator light will blink the permit join is enabled and the device is joined Please note that the maximum waiting to join period is 60 seconds blinks 60 times Repeat the process if you missed the 60 seconds period Restore to factory setting Z805 is capable of storing and saving includes network routing information If you wish to remove Z805 from an exited network you would need to clear the saved routing information to join to a new network by simply reset the device to restore to the factory setting Remove Z805 from the power socket use a pin and hold on to the binding key While doing so plug Z805 back to the power socket to give power then release the pin Now the device is restored to the factory setting and is ready to join to a new network End user specification At the time of power recovery from power outage by default the device remains turned off at the output This may sometimes cause inconvenience to the user finding the fridge isn t functioning after the power recovery Netvox offers End User requirement before shipment that means we can change the default output position to which you want it whether power stays on off or remember you previous status in t
3. elays of control data between devices with only a fraction of energy use which denoted for highly transmission efficiency Note Wireless communication in some real use cases can be limited by the signal blockage Please consult your service provider or place of purchase setting up the Z805 and network Here are the summarized steps 1 Powering on the device 2 Join it into the existed network Note when successfully joined we strongly suggest you to allow 1 minute performing self calibration on the meter before it is ready to take load This is particular important for correct reading 3 Bind the device with other device where applicable i e bind it with a ZigBee switch for wireless control 4 When it is bind with a controlling device it is then ready to be used 5 Power current consumption monitoring Step 1 Power on the device To connect the device to the power source wire the live wire labeled L IN and the neutral N to the 100 240V AC To control your unit connect your appliances or machine to the L OUT and N Step 2 Join the network When Z805 is powered it will search for an existed network and will ask to join the network of the same channel automatically If it is within a coordinator or other router coverage area it is permitted to join The LED indicator on the Z805 will flash A non flashing solid light indicates success join otherwise the indicator stays dark Step 3 Binding Z805 can be bou
4. he time of power recovery we can make it to suit different home appliance for you Just let us know in the time of your order Device attributes description Z805 uses attribute of current voltage or power and is presented by their Cluster ID and Attribute ID These are Netvox defined parameters There are four attributes under Cluster ID 0x0702 namely the current attribute OxEO0O the voltage attribute OxE001 the power attribute OxE002 and the energy attribute OxE003 The realization of on or off control commands are basically the On Off Toggle commands specified in Home Automation Profile The attribute format is given bellow Cluster ID 0x0702 Current Attribute Attribute ID OxEO00 Name MainsCurrent Type Unsigned 16 bits Integer Range 0xO000 OxFFFF Access Read Only Default 0x0000 Voltage Attribute Attribute ID OxEO001 Name MainsVoltage Type Unsigned 16 bits Integer Range 0x0000 OxFFFF Access Read Only Default 0x0000 Power Attribute Attribute ID OxEO002 Name MainsPower Type Unsigned 16 bits Integer Range 0x0000 OxFFFF Access Read Only Default 0x0000 Energy Attribute Attribute ID 0xE003 Name MainsEnergy Type Unsigned 32 bits Integer Range 0x00000000 0xFFFFFFFF Access Read Only Default 0x00000000 Units something you want to know 1 For monitoring accuracy please allow Z805 to do one minute of self calibration Self calibration is performed immediately it is joined into a new network Re
5. member to perform factory restore when join into a new network 2 While performing binding or matching make sure no loads are attached to Z805 3 This device involved high AC voltage and may cause hazard to the user We strongly suggest you to use a non conductive pin to do reset Any conductive material such as paper clipper is strongly not encouraged Important Maintenance Instructions As the device is not water proof it is recommended to keep the device in a dry place Liquid and heavy moisture contains minerals that may oxidize the electronic circuitry In case of liquid spill please leave the device to completely dry before storing or using e Do not use or store the device in a dusty area Dust may cause electronic parts to destroy e Do not use or store the device in an over heated place Store in a hotter temperature than the suggested maximum temperature may shorten the life span of the device and may damage the battery and causing the housing to deform e Do not use or store the device in a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that is higher in temperature This can severely damage the PCB board and circuitry This may shorten the life soan of the device damage the battery and cause the housing to deform e Do not throw or strongly vibrate the device This may damage connectivity of the electronic parts and other sensitive components on the PC
6. nd with a ZigBee enabled Home Automation on off switch Netvox Z501 for wirelessly control within the network coverage area Binding operation note make sure the cable near S1 should not be connected To send out the binding request press the bind key for 3 seconds the indicator light flashes once Now quickly do the same to the other device you wish to bind with If binding failed the light indicator on Z805 will blink 10 times The light is normal when binding is successful Step 4 How Z805 is controlled A switch control device that is bound to Z805 may sent on or off command when you press a on or off button the contact of the relay in the Z805 would either closed or open the circuit Z805 can also be controlled by a manual switch attached on the S1 cable Step 5 Match Connect S1 cable hold and press the binding key for 3 seconds the indicator flashes once to send out Match request to the air The indicator flashes 6 times if successful Step 6 Power Current consumption monitoring When the load is attached to Z805 and is up running the embedded meter monitors the supplied voltage and current consumption for Z805UI or load power and overall power consumption over time for Z805 PE Z805 reports the readings to the matched display device periodically and the user can watch the readings on the application software on the host computer Permit to join Z805 is featured to be a router in the network It permits join other
7. netvoyx ZigBee Power Socket with Energy Consumption Monitoring Power Outlet User Manual Model Z805PE for Power amp Energy Z805UI for Voltage amp Current Energy Consumption Monitoring Series Power Outlet Other Netvox related devices Switch controller Power amp Energy Z805PE e Simple controller Z501 series Voltage amp Current Z805UI e Multiple Scene controller Z503 e Wall switch ZB02 series e Light sensor Z301B e Full application software ZiG Butler Figure Z805PE amp Z805U Introduction Z805 is a power socket device with power consumption monitoring feature In the network Z805 functions as a router device in the network which permit join other devices to the network The device can be bind with a ZigBee enabled on off remote device to control It can be switch on or off the appliance attached to it upon receipt of a control command It can also be done manually from the switch Netvox has its proprietary energy management system such as ZIG BUTLER software to view power or current consumption ZigBee is a short range wireless transmission technology which defined for a minimum complexity low power consumption low data rate cost effective wireless solution ZigBee lies in between wireless markup technology and Bluetooth ZigBee is based on IEEE802 15 4 standard the mutual co ordination between thousands of sensors to exchange data Sensor to sensor or node to node communication is achieved through r

Download Pdf Manuals

image

Related Search

Related Contents

Guide de dépannage  Manual Disponível - Metalúrgica Siemsen  Models: DF-F8007b & DF-F8008w  Rommelsbacher CT 2215/IN hob  Home Decorators Collection 32196 Installation Guide  Ashly NE 4200.25 User's Manual  questionnaire de l`ISU sur les programmes d`enseignement nationaux  

Copyright © All rights reserved.
Failed to retrieve file