Home
USER MANUAL
Contents
1. b Y B I Remove the plastic pad from Affix a sticker with the name cut to size on the white space Insert the pad back in the the keyboard module allocated to it keyboard module 07 gt CONNECTION DIAGRAM ale ne 230 V AC 50Hz D N F Electrical panel J 2x Sig 104 ORANGE ORANGE lt gt a Nonna e q a om A Bhin i 24 Panel OUTDOOR INDOOR gt eS F 5 Joe EAN Supply control unit Accumulator Optional ae Pa acc 2x05mm cable ORANGE ORANGE Doorbell Terminal Door Opening button Optional Direct current electromagnetic lock Optional Alternative current electromagnetic lock Optional Direct current DC Cable 2x0 75 mm Direct current electromagnetic lock DC Supply control unit The Supply control unit can supply a current of max 1A for the supply of the lock The tension of 14 V DC is present on thd LC terminal of the Supply control unit The connection of a lock actuating button from the interior of the building will be made at the BUT T and fara of the Supply control unit 5 1 Installation of the electromagnetic lock optional Alternative current AC Transformer 230V AC Alternative current electromagnetic lock AC Supply control unit e The Supply control unit can supply a current of max 1
2. AC network by connecting the two automatic 10A fuses installed on phase and null Optionally connect the accumulator to the ACC Jand ACC terminals of the Supply control unit Q PAY ATTENTION to the polarity of the accumulator Check the existence of the supply tensions with the values mentioned below at the terminals of the Supply control unit use a direct current voltmeter e Tensions measured at the terminals of the Supply control unit 13 8 14 3V DC e The tension Uv 13 5 14 3V DC is not used by the audio systems e Tensions measured at the terminals of the Outdoor panel and at the terminals of the Terminals GND min 12 V DC 09 6 3 Checking the functions and adjustments Check aN in the installation during the call and the communication and make sure that the GND supply tension is higher than 12 0V Check the functions of the Terminals and of the Outdoor panel call communication access audio monitoring The system is adjusted by the producer in what concerns the audio part for standard functioning conditions How to adjust the volume of the audio Terminal Through consecutive touches of the VOLUME key different audition levels are obtained OFF mute red LED MEDIUM white red LED MAXIMUM white LED After checking leave the Terminal on the open volume position white LED on 6 4 Troubleshooting Any intervention in the system will be made with the system disconnected from A
3. the 230VAC supply network the phase and null fuses are opened and from the accumulator the ACC terminal is disconnected Se Control unit The system functions S1 green correctly S2 green PROG Check the 10A fuses from The system does not Control unit the electrical panel and function supply Si Lack of tension from the 1 6A Fuse 1 from the 1 control unit without S2 the 230VAC network Supply control unit input accumulator PROG Check the continuity of the supply cables The system does not Control unit Short arcuitinthe Identify the spot of the 2 function supply S1 intermittent green system between 14V short circuit Remedy the control unit without 52 ni defect and turn the accumulator PROG system on Control unit S1 green S2 green PROG No CD connection Connect the CD to the Terminal at the terminals of the Terminal or check the z The CALL does TEE Terminal or CD continuity of the Poan functioning it does yo nee ee Horn VIRARO not take the call a me connection box to command the Terminal Terminal Outdoor panel Emits an error signal Control unit S1 green S2 green PROG intermittent red Terminal Short circuit between a 4 The CALL does The keyboard is the D Jand Remedy the short circuit not function functioning it does ae ae by case not take the call command Outdoor panel Emits an error signal Control unit The syst
4. 14 USM KIT APB 1F0 ENY
5. 15V DC or directly from the network 230V 50Hz DANGER OF ELECTRIC SHOCK and of the door phone system s destruction 4 3 Installation of the supply control unit DIN rail mounting i DIN rail o o rroo L CTRA SUPPLY CONTROL UNIT C v 50 A DO NOT UNFASTEN Th FETY UD frm Outpst 1 14V 2A d arany pat 2 14 05 Ad bo Wall mounting o o olay eo 3 fei A3 5 x 32 screw 2 pcs Protection lid 2 pcs B2 9 x 13 screw 4 pcs 05 140 7 130 0 Frontal view Lateral view Back view The accumulator will be connected to the terminals of the power supply after the commissioning of the system 4 4 Installation of the audio terminal Before starting A3 5 x 35 32 screw ri 4 pcs A lan A Cable retainers adapters aoao TN ee tl v 5 ISS 2 The terminal will be placed at 155 cm Cable length height recommended height from the wall 96 5 29 5 21 LA a N ba Frontal view Lateral view Back view 06 4 5 Installation of the Outdoor panel The Outdoor panel is installed at the entrance of the property or building on the body closest to the access door at a height of approx 1 7 m upper part from the
6. A for the supply of the lock 08 6 COMMISIONING OF THE SYSTEM EN 6 1 Description of the Supply control unit Th ly control unit includes e supply control unit includes S1 presence of tension at the 14VH GND terminals PROG mab S2 existence of tension programming pulton at thel Uv GND terminals The kit does not require programming This button is used only if you Protection lid for add additional Terminals connections or Panels to the system audio RED signaling O ELECTRA E X of PROG SUPPLY CONTROL UNIT Front lid defect within Input 230V 50Hz 0 4 A a c DO NOT UNFASTEN THE h 10 1 2 Output 1 14V 2 A d c S1 gta t e system i 8 4 Output 2 14V 0 5 A d c S2 AN ELECTRIC SHOCK TIME Lock timing adjustment Protection lid for connections 6 2 Checking the precision of the connections in the system and the connection of the supply control unit Check the precision of the connections in the system The i CD Signals are common to all components of the system Any short circuit between them leads to the non operation of the entire system With an ohmmeter check that there is no short circuit between any terminals anywhere in the system Make sure that the Torx screw of the Outdoor panel is completely screwed to prevent turning on the anti theft alarm Connect the Supply control unit to the 230 V
7. USER MANUAL KIT AUDIO DOOR PHONE basic 1 family L CTRA ooooo ELECTRA Harry Johnston A D00000000OOOC0OO00COOO000000000000000 00000000CCCOCC0C00COCO000000000000000 0000000CCCOCOCCCO0COCOC000000000000000 000000COCCCOCOC0CO00COCC000000000000000 O0000OOCOCOCOCOOCOCOC000000000000000 C00000000CCCOCOO0COCC000000000000000 basic e Call from the Outdoor panel s key Full duplex hands free audio communication e Command of the access gate door opening from the interior Terminal e Audio monitoring of the entrance of the property by the inhabitant e Optional 1 audio Terminal in parallel UTP CAT 5e AWG 24 cable required L CTRA 1 KIT COMPONENTS Outdoor panel Terminal Supply control unit 1 pc 1 pc 1 pc 238 x 144 x 53mm 170 x 96 x 30 mm 150 x 141 x 73 mm Z2 TECHNICAL FEATURES OF THE SYSTEM Audio communication Full duplex Data communication Digital Supply tension of the system supply of the control unit Maximum power expenditure from the 230 V AC network 230 V 10 50 Hz 0 4 AAC 2 1 Technical features of the outdoor audio panel Supply tension 12 0 14 3 V DC stabilized Keyboard TOUCH type permanently backlit Display of the inhabitant s name Backlit name space Aluminum profile painted in electrostatic field Case Secured glass screen 8 mm th
8. atic fuses of 10 A on phase and null The connection of the F and N terminals of the Supply control unit will be made through two isolated Cu wires with a section of 0 75mm7 ATTENTION During the installation connection of the Supply control unit at the 230 V 50Hz network and during service the safety fuses from the panel must be opened POWER OFF The connection of the Cu 0 75mm grounding wire between the grounding terminal of the electrical panel and the grounding terminal of the Supply control unit is MANDATORY IMPORTANT Before connecting the Supply control unit s supply fuses check the precision of the connections in the system Check both visually and by measurement with an ohmmeter IMPORTANT Install the protection lids of the Supply control unit s connections before connecting the 2 supply fuses 230V 50Hz PAY ATTENTION to the polarity of the terminals when connecting them to the Supply control unit of a buffer accumulator max 7 Ah The inversion of the terminals leads to the failure of the accumulator The installation and connection of the accumulator will be carried out by authorized personnel DO NOT TOUCH the wires exiting from the connectors and the terminals of the control supply unit Disconnect the fuses 10 A from the supply s phase and null of the Supply control unit ATTENTION Do not supply components of the installation separately Outdoor panel connection boxes Terminals etc at tensions higher than
9. em functions S1 red a The accumulator is in 5 supply control unit intermittent green ok i charging mode with accumulator S2 green PROG Control unit The system functions S1 red intermittent 6 Supply control unit green Defect accumulator or Change or recharge with accumulator 32 ee discharged the accumulator acoustic signal PROG Lack of tension from Check the 10A fuses from The system functions Control unit the 230V AC network the electrical panel and 7 supply control unit Si red The system functions the 1 6A Fuse 1 from the with accumulator 52 powered by the Supply control unit input PROG acc mualat r Check the continuity of the supply cables 7 USE 7 1 User safety instructions Do not hit the glass screen with hard objects If the front glass screen cracks DO NOT touch the product 11 7 2 Use of the audio Terminal 1 STAND BY At the first touch the keyboard is backlit and the Terminal may receive the following commands AUDIO MONITORING Monitoring duration 10s By touching this key you may listen to what goes on at the entrance in front of the Stand b a Outdoor panel Monitoring is not possible if another Terminal of the system is being called or is during communication VOLUMEADJUSTMENT OR TERMINAL TURNED OFF By successive touches of this key the 3 volume levels are passed through maximum white LED medium red white LED and turned off red LED T
10. ground protected from rain and sunrays 144 0 Before starting b TE 48 5 4 0 The Outdoor panel is installed at the entrance to the building on the 222 40 238 0 198 0 174 0 E T body closest to z the entrance door JWT A HEE STE S 1 i Frontal view Lateral view x Back view Torx Screw The frame i th maa of the case 3 F must be at the level of the wall s surface 20 cm 3 cable length Door phone cable Torx Screw for antitheft protection Antitheft protection 1 m 2 Torx Screw gt 0 Ll The Torx screw must be completely screwed Otherwise when the system is powered the panel emits a permanent acoustic signal This warning function is useful if an unauthorized person tries to open the Outdoor panel The alarm turns on immediately after one starts to unscrew the Torx The function is turned off during the programming of the panel s parameters Customization of the name display Tle R Q oa ooo 10 10 20 20 CE X 30 a CE X so EEEE 1 H 2
11. he red LED will remain permanently turned on until the key is pressed again 3 I3 2 CALL AND COMMUNICATION Call duration maximum 15 s 3calls basic Call ANSWER THE CALL Communication duration maximum 2 min The LED of the key blinks By touching the key communication is initiated The LED does not blink anymore Do not touch the key during communication END COMMUNICATION WITHOUTACCESS The second touch of the key ends communication without granting access and the Terminal returns to stand by mode LICIO Communication Z ACCESS ACCESS and END COMMUNICATION After the command the lock is unblocked for 1 10 s for the access of the visitors You cannot grant access without having a prior communication 12 7 53 Use ofthe Outdoor panel PS 1 STAND BY The key of the Outdoor panel and the inhabitant s name are permanently backlit 2 CALL AND COMMUNICATION Call duration maximum 15 s 3 calls Communication duration maximum 2 min Touch the Akey The call to the inhabitant is signaled acoustically You may end the call by pressing again the key If the inhabitant answers communication is initiated If access is granted the panel emits an acoustic signal and the lock remains unblocked for maximum 10 seconds If the inhabitant does not answer after a minute the panel returns to stand by mode 8 MAINTENANCE The outdoor panels mu
12. ick Mounting Flush Casing protection level IP P44 Operating temperature range 30 Cac 60 C E and storage temperature 33 C 455 C Dimensions 238 x 144 x 53mm Weight 1 3 kg 02 2 2 Technical features of the audio Terminal Supply tension 12 0 14 3 V DC stabilized TOUCH type 4 keys backlit on touch Keyboard Permanent RED signaling of the VOLUME key if the Terminal is turned off Audio adjustments Audio communication volume MAXIMUM LEVEL MEDIUM LEVEL TURNED OFF c ABS an Glass screen 3 mm thick Casing protection level IP IP31 Operating temperature range 0 C 45 C Range of transport and storage s temperatures II Ca tC Dimensions 171 x96 x 40 mm 2 3 Technical features of the Supply control unit Supply tension 230V 10 50Hz P ete GND 14V DC stabilised 2A DC enerate ower tensions power anes GND 14V DC stabilised 0 5A DC Vcam 12V DC stabilised 0 4 A DC On DIN rail TH 35 x 15 or 35 x 7 5 in compliance Surface with A3 5 x 32 plastic screws and 6mm pins Casing protection level IP IP31 Operating temperature range 0 C 45 C R ft t and st Ne ORE temperatures 03 5 BLOCK DIAGRAM OF THE SYSTEM All additional products are sold separately INDOOR ice Accumulator 9 12V 7Ah Optional OUTDOOR 2 Optional Electro
13. magnetic E lock DC AC S ee Supply control unit Terminal Panel Additional terminals in parallel optional 3 From the supply A control unit Main terminal Additional terminal 1 4 INSTALLATION Outdoor panel Supply control unit Audio Terminal UTP CAT5e AWG 24 cable for distances of maximum 70 m between the Outdoor panel and the Supply control unit and 250m between the Outdoor panel and the audio Terminal For distances greater than 250 m please request additional information from the producer Supply control unit gt Electromagnetic lock optional Flexible multistrand cable Cu 2 or 3 x 0 75 mm for distances of maximum 50 m or Cu 2 or 3 x 1 mm for distances of maximum 100 m Supply control unit gt 230 V AC network Flexible multistrand cable Cu 3 x 0 75 mm 4 2 Safety instructions for installation ATTENTION The installation the connection to the 230V 50 Hz network and the maintenance of the Supply control unit Supply control unit will only be carried out by authorized personnel The installation of the Supply control unit is recommended to be made within an electrical panel ATTENTION DO NOT UNFASTEN THE FRONT LID DANGER OF ELECTRIC SHOCK Only the protection lids of the connections can be unfastened ATTENTION It is mandatory for the supply of the Supply control unit from the 230 V 50Hz network to be made through two autom
14. st be kept away from corrosive substances lime or mechanical shocks The terminals must be kept away from water or any other liquids mechanical shocks fumes dusts etc The components of the system can be cleaned with a piece of soft cotton cloth The optional accumulator connected with the supply control unit will be replaced after the expiry of its life span The supply control unit ensures the accumulator s charging as long as the accumulator is not defect The state of the accumulator is indicated by the signals of the LED S1 and the acoustic warning in case of a defect 9 WARRANTY A three year warranty is granted from the purchase date on the basis of the proof of purchase and if the system was used according to the technical manual NO WARRANTY IS GRANTED for inappropriate installation and use A deliberate damaging theft arson natural disasters unauthorized interventions to the system the lack of protection of the system s components in case of renovation activities in the building The ELECTRA systems for residential buildings are produced in compliance with the EU standards and bear the CE conformity marking TO AUTHORIZED REPRESENTATIVE of ELECTRA S R L ELECTRA Building Communications GmbH Parkring 10 Liebenberggasse 7 1010 Wien Austria CE RoHS A Phone 43 1 516 33 3817 Fax 43 1 516 33 3000 office electra automation at Designed and Manufactured by ELECTRA Made in EU 11 20