Home

Split FTKV FTKC Series

image

Contents

1. Ti INVERTER FTKC20PVMV FTKC25PVMV FTKC35PVMV FTKC50NVMV FTKC60NVMV A New Kind of Cool Urusara puts the latest Japanese air conditioning technology at your fingertips offering a unique total comfort experience for any lifestyle Powerful year round cooling and dehumiditying are just the beginning Urusara 7 is also the world s first air conditioner to use next generation R 32 refrigerant Along with its many energy saving features this higher performance refrigerant gives Urusara unrivalled energy efficiency Features Redesigned air intake and heat exchanger World first humidity control technology Precision circulation airflow Reliable streamer discharge air purification Convenient automatic filter cleaning system Innovative design with Japanese aesthetic UrUSorga uw Daikin Air Conditioner Made in Japan Category Product Design 2013 Notes 1 This is for residential use wall mounted type air conditioners as of November 2012 when Daikin launched Urusara 7 the Japanese market 2 In January 2013 the 4 0 to 7 1 kW class models for the Japanese market received the Minister s Prize from Japan s Ministry of Economy Trade and Industry in the Fiscal 2012 Grand Prizes for Excellence in Energy Efficiency and Conservation 3 As of 1999 when Daikin launched Ururu Sarara in the Japanese market FI KJ Series Form Function Design sleek E
2. fee Weekly Timer ONOFF The Weekly Timer allows up to four actions to be programmed for each day of the week It is possible to schedule not only the on and off times but also the desired temperatures during these periods The copy function also makes the setting much easier and enables a daily programme to be repeated on other days as required This function is available for FTKV50 60 71 gt See pages 25 and 26 Night Set Mode Pressing the Off Timer button automatically selects Night Set Mode This function prevents excessive cooling for a pleasant sleep After 60 minutes the room temperature is raised by 0 5 C for cooling operation P See page 24 MIO eee i Cooling Set temp before e Off timer begins to operate A 60 min A Unit minutes Off timer turns on Off timer stops air conditioner Lifestyle Convenience Standby Electricity Saving Even when an air conditioner is not operating it requires standby power Q However thanks to this function the required standby power can be reduced This function is available for FTKV50 60 71 and FTKC50 60 gt See page 20 Econo Mode This mode limits maximum power consumption This improves operating efficiency and also prevents circuit breakers from being overloaded gt See page 20 Inverter Powerful Operation This function boosts cooling performance for 20 minute period It is convenient when the air conditioner is first turned on or it is nec
3. y Warning Ask a qualified installer or contractor to install this product Do not try to install the product yourself Improper installation can result in water or refrigerant leakage electrical shock fire or explosion e Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage electrical shock fire or explosion R ead the user s manual carefully before using this product The user s manual provides important safety instructions and warnings Be sure to follow these instructions and warnings If you have any enquiries please contact your local importer distributor and or retailer Cautions on product corrosion 1 Air conditioners should not be installed in areas where corrosive gases such as acid gas or alkaline gas are produced 2 If the outdoor unit is to be installed close to the sea shore direct exposure to the sea breeze should be avoided If you need to install the outdoor unit close to the sea shore contact your local distributor DAIKIN INDUSTRIES LT D T x e HEAD OFFICE Dal ly ph n phot Umeda Center Bldg 2 4 12 Nakazaki Nishi Kita ku Osaka 530 8323 Japan CONG TY CO PHAN VIET KIM e VAN PHONG CH NH Tang 14 15 toa nh Nam A 201 203 C ch Mang Thang 8 P 4 Q3 TP HCM
4. 4 400 14 000 FTKV50 60NVMV RKV50 60NVMV INVERTER FTKV50NVMV RKV50NVMV Cooling Capacity Btu h 17 700 5 800 20 500 5 0 FTKV60NVMV RKV60NVMV KW 6 0 1 9 7 0 Cooling Capacity Rated Btu h 20 500 6 500 23 900 FTKV71NVMV e RKV71NVMV Cooling Capacity INVERTER FTKV71NVMV RKV71NVMV kW 7 1 2 3 8 9 Btu h 24 200 7 800 30 400 Rated Min Max Lineup of Series FTKC Series n FTKC20 25 35PVMV Sm UU e RKC20 25 35PVMV INVERTER 13 Cooling Capacity Cooling Capacity E Cooling Capacity LA dil 7 FTKC20PVMV RKC20PVMV Rated Min Max kW 2 0 1 0 2 4 Btu h 6 800 3 400 8 200 FTKC25PVMV RKC25PVMV Rated Min Max kW 2 5 1 0 3 4 Btu h 8 500 3 400 11 600 FTKC35PVMV RKC35PVMV Rated Min Max kW 3 5 1 3 4 1 Btu h 11 900 4 400 14 000 i FTKC50NVMV RKCB0NVMV i kW 5 2 1 6 5 9 pg Cooling Capacity it _ Btu h 17 700 5 500 20 100 FTKC50 60NVMV Ji FTKC60NVMV RKC60NVMV kW 6 0 1 8 6 9 Cooling Capacity it l Min Max Btu h 20 500 6 100 23 500 2 d i RKC50 60NVMV INVE
5. Tel 08 62 504 888 Fax 08 62 504 999 e CHI NH NH H N I Tang 12 t a nh Ocean Park Tower 1 Dao Duy Anh Quan B ng a H N i Tel 04 35 657 677 _ Fax 04 35 657 688 e CHI NH NH D NANG Mi n ph cu c cu c goi Tang 12 L A2 1 Dudng 30 4 P H a Cu ng Hai Chau TP Da Nang Tel 0511 362 4250 Fax 0511 362 4251 www daikin com vn e Specifications designs and other content appearing in this brochure are current as of March 2015 but subject to change without notice All rights reserved Printed in Vietnam 11 13 001 VK Split Type Air Conditioners 7 412809 32 Urusara 7 FTKJ Series FTKV Series FTKC Series FTKJ Series PCRVN1447A E Urusara 7 Lineup of DC Inverter Air Conditio ners with R 32 Refrigerant Our cutting edge technologies and use of advanced R 32 refrigerant provide Daikin is the sole manufacturer to produce both air conditioning equipment and refrigerants worldwide enhanced comfort while reducing the impact on climate change 2 0 kW Class 2 5 kW Class 3 5 kW Class 5 0 kW Class 6 0 kW Class 7 1 kW Class Urusara 7 INVERTER FTXZ25NVMV FTXZ35NVMV FTXZ50NVMV FTKJ Series INVERTER FTKJ25NVMVW white FTKJ35NVMVW white FTKJ50NVMVW white FTKJ25NVMVS silver FTKJ35NVMVS silver FTKJ50NVMVS silver FTKV Series i 127 i 125 INVERTER FTKV25NVMV FTKV35NVMV FTKV5ONVMV FTKV60NVMV FTKV71NVMV Series
6. It has now adapted this high efficiency motor for the swing compressors in its residential use systems _ Magnetic power Rapid switching Electromagnet Hepelling power Embedding high strength neodymium magnets in the shaft turns the entire centre of the motor into a powerful magnet By rapidly switching the poles of this electromagnet the Reluctance DC motor is able to produce even greater speed and power High COPs of 3 45 to 4 63 The FTKV series achieves COPs of 3 80 to 4 63 and the FTKC series 3 45 to 4 00 thanks to Daikin s DC Inverter control and combined energy saving technologies The FTKV series have received Vietnam s 5 Star Energy Label which is the country s highest energy efficiency rating for inverter type air conditioners The FTKC series have received Vietnam s 5 Star Energy Label What Is COP An air conditioner s COP coefficient of performance indicates how efficiently Capacity W the unit uses energy A higher COP means greater energy efficiency It also means lower electricity consumption and of course lower power bills Power consumption W The Next Generation Refrigerant R 32 As the sole worldwide manufacturer of both air conditioning equip ment and refrigerants Daikin is continuously researching refrigerants as well as new technologies that can save energy consumption for air conditioners Use of the refrigerants with a lower impact on global warming is urgently
7. controller 2 Unified On Off controller 3 Schedule timer 4 Interface adaptor for DIII NET use Note 1 Interface adaptor for use KRP928BB2S is also required for each indoor unit Central remote controller Unified On Off controller Schedule timer DCS302CA61 DCS301BA61 DST301BA61 FTKC50 60 KRC72A KRP413AB1S RKC50 60 KPW945A4 FTKC50 60 DCS302CA61 DCS301BA61 DST301BA61 KRP928BB2S 38
8. modern appearance which blends easily with any interior decor 32 Wireless Remote Controller FTKV25 35 On and Off switch Selects fan speed Auto Fan Speed and Indoor Unit Quiet Operation Inverter Powerful Operation Selects operation mode Cooling Dry and Fan Only Outdoor Unit Quiet Operation 24 Hour Off Timer and 6 Night Set Mode Cancels timers FTKV50 60 71 On and Off switch Selects fan speed S Auto Fan Speed and Indoor Unit Quiet Operation amp Inverter Powerful Operation Selects operation mode Cooling Dry and Fan Only Comfort Airflow Mode and Intelligent Eye Starts and completes settings Deactivates reactivates or deletes Weekly Timer settings Goes back 24 Hour Off Timer and Night Set Mode Cancels timers 10 33 The backlit LCD allows easy operation in the dark Sets room temperature Econo Mode Sets vertical airflow direction Vertical Auto Swing Intelligent Eye Selects time 24 Hour On Timer Sets clock The backlit LCD allows easy operation in the dark Sets room temperature Econo Mode and Outdoor Unit Quiet Operation Sets vertical airflow direction Vertical Auto Swing 1 and 3D Airflow Sets horizontal airflow direction Horizontal Auto Swing 7 and 3D Airflow Copies settings Goes next Selects timer mode setting Significant number day time and temperature 24
9. red Sensors Intelligent Eye Intelligent Eye prevents energy wastage by using its infrared sensors to detect human movement in a room If there is no movement for 20 minutes it automatically adjusts the set temperature by approximately 2 C Once Intelligent Eye is turned on it operates E automatically without any further setting This function is available for FTKV series Intelligent Eye Intelligent Eye indicator sensor U U T If Intelligent Eye detects no movement for 20 minutes it adjusts the set temperature by approximately 2 C When a person enters the room it automatically returns the temperature to the set level 19 his function limits the maximum power consumption It helps to reduce power usage if the cooling load is high for example at startup or during large gatherings and periods of direct sunshine Normal operation Econo Mode Power consumption ime Maximum capacity decreases during Econo Mode requiring more time to reach the set temperature Standby Electricity Saving Electrical appliances still use a surprising amount of power even when they are waiting in standby mode Recognising this Daikin has developed the Standby Electricity Saving function to reduce this hidden power consumption This function is available for FTKV50 60 71 and FTKC50 60 20 21 Choice of Wide Hange of Airfl
10. required because climate change has been one of global critical issues Daikin has now adopted R 32 This next genera tion refrigerant does not deplete the ozone layer and lower impact on global warming H 32 Features 1 Zero ozone layer depletion 2 Low global warming potential 3 Increased energy efficiency 4 Less impact on global warming Notes 1 Values are based on in house simulations Electricity Consumption after One Year of Operation 58 energy saving 1 132 kWh Non inverter type Inverter type Compared to non inverter models Urusara 7 cuts power consumption by up to 58 This helps to reduce electricity bills for the user and also decreases CO2 emissions caused by power generation 2 Daikin s achievement was recognised by the Institute of Electrical Engineers of Japan at the 54th Academic Promotion and Technical Development Awards in 1998 3 Test method In house simulation based on the principles of JIS C9612B 1 6 5 for inverter models and JIS C9612B 1 6 4 for non inverter models Test inverter model 3 5 KW class model of Urusara 7 for the Thailand market rated COP 5 00 COP in the partial load region 6 39 Test non inverter model 3 5 kW class Daikin non inverter model for the Thailand market COP 3 45 Test location Bedroom of 24 m Test conditions Annual average outdoor temperature in Bangkok Test period 9 hours of operation from 10 00 p m to 7 00 a m ess Wasted Energy with Infra
11. 28BB25 RKV71 KKP945A4 36 Specifications for FIKC Series Indoor unit FTKC20PVMV FTKC25PVMV FTKC35PVMV FTKC50NVMV FTKC60NVMV mode Outdoor unit RKC20PVMV RKC25PVMV RKC35PVMV RKCSONVMV RKCGONVMV Rated kW 2 0 1 0 2 4 2 5 1 0 3 4 3 5 1 3 4 1 5 2 1 6 5 9 6 0 1 8 6 9 Capacity 6 800 8 500 11 900 17 700 20 500 Min Max Btu h 3 400 8 200 3 400 11 600 4 400 14 000 5 500 20 100 6 100 23 500 Power supply 1 phase 220 240 V 50 Hz 1 phase 220 230 V 60 Hz Running current A 2 6 d d 4 5 6 7 8 0 Power consumption Rated W 500 700 990 1 445 1 740 COP W W 4 00 3 57 3 54 3 60 3 45 Indoor unit FTKC20PVMV FTKC25PVMV FTKC35PVMV FTKC5ONVMV FTKC60NVMV Front panel colour shiny pure white Airflow rate H m min cfm 9 0 318 9 3 324 14 3 504 15 4 544 Fan speed 5 Steps quiet and automatic Sound pressure levels H L SL dB A 38 25 22 39 26 22 42 32 29 44 34 31 Dimensions HxWxD mm 283 x 770 x 203 290 x 1 050 x 237 Machine weight kg 0 12 Outdoor unit RKC20PVMV RKC25PVMV RKC35PVMV RKC50NVMV RKC60NVMV Casing colour Ivory white Type Hermetically sealed swing type Motor output W 441 641 913 1 300 R 32 Charge kg 05 07 12 Sound pressure levels H SL dB A 46 4T 49 48 44 92 46 Dimensions HxWxD mm 550 x 658 x 275 35 x 825 x 300 Machine weight kg 23 22 26 43 Operation range CDB 19 4 to 46 Piping Liquid 96 4 Gas mm 09 5 012 7 Drain 916 0 918 0 Max piping length m 15 30 M
12. 71NVMV 2 400 1 5 22 49 770 x 900 x 320 60 015 9 Options for FTKV Series Indoor Unit No 1 5 room centralised controller 2 Wiring adaptor for time clock remote controller Normal open pulse contact normal open contact 3 Titanium apatite photocatalytic air purifying filter A Remote controller loss prevention with chain Notes 1 A wiring adaptor KRP413AB1S is also required for each indoor unit 2 The time clock and other devices should be obtained locally 3 The filter is a standard accessory Titanium apatite photocatalytic 5 room centralised controller KRC72A air purifying filter KAF970A46 Outdoor Unit No ltem 1 Air direction adjustment grille 2 Drain plug Note 1 One set includes five pieces for five units Air direction adjustment grille KPW945A4 Control System No Item 1 Central remote controller 2 Unified On Off controller 3 schedule timer 4 Interface adaptor for DIII NET use q 3 RKV25 35 KPW937A4 b wwe Drain plug KKP937A4 Note 1 Interface adaptor for use KRP928BB2S is also required for each indoor unit Central remote controller DCS302CA61 DCS301BA61 Unified On Off controller Schedule timer DST301BA61 FTKV25 35 50 60 71 KRC72A KRP413AB1S KAF970A46 KKF910A4 f Remote controller loss prevention with chain A4 RKV50 60 KPW945A4 KKP937A4 FTKV25 35 50 60 71 DCS302CA61 DCS301BA61 DST301BA61 KRP9
13. D mm 295 x 798 x 370 P1 1 Lineup of FTKV Series Outdoor unit RXZ25 RXZ35 RXZ50 1 3 Lineup of FTKC Series P23 Quiet Nights in Your Neighbourhood Dimensions HxWxD mm 595 x 795 x 300 See the Urusara 7 catalogue for details 4 P P1 S Inverter Advantages P25 Set and Forget On Off Operation AK X a FTKJ Series 25 35 white B FTKJ25 35 50 silver Model name FTKJ25 white FTKJ35 white FTKJ5O white Indoor unit FTKJ25 silver FTKJ35 silver FTKJ50 silver Outdoor unit RKJ25 RKJ35 RKJ50 kW 2 5 1 2 3 4 3 5 1 3 4 1 5 2 1 7 5 5 p Cooling capacity Rated Min Max aw Btu h 8 500 4 100 11 600 11 900 4 400 14 000 17 00 5 800 18 800 P1 7 DC Inverter Advantages P2 Photocatalytic Air Purifying Power consumption Rated Ww 520 855 1 450 Indoor unit FTKJ25 white FTKJ35 white FTKJ50 white Function List of FTKV and FTKC Series P29 FTKJ25 silver FTKJ35 silver FTKJ50 silver Functions P31 B Specifications and Options for FTKV Series P35 Outdoor unit RKJ25 RKJ35 RKJ50 P19 Less Wasted Energy with Infrared Sensors Specifications and Options for FTKC Series P37 Dimensions HxWxD mm 550 x 765 x 205 735 x 825 x 300 See the FTKJ series catalogue for details FTKV Series It s Time for DC Inverter Inverter air condi
14. Hour On Timer Sets clock FTKC20 25 35 Sets room temperature Econo Mode Inverter Powerful Operation Selects operation mode Cooling Dry and Fan Only 4 Comfort Airflow Mode 24 Hour On Timer 24 Hour Off Timer and Night Set Mode FTKC50 60 Sets room temperature Econo Mode Inverter Powerful Operation Selects operation mode Cooling Dry and Fan Only Outdoor Unit Quiet Operation 24 Hour On Timer 24 Hour Off Timer and KA Night Set Mode On and Off switch Selects fan speed Auto Fan Speed and Indoor Unit Quiet Operation Sets vertical airflow direction Vertical Auto Swing Cancels timer Selects time Resets settings Sets clock On and Off switch Selects fan speed Auto Fan Speed and Indoor Unit Quiet Operation Sets vertical airflow direction Vertical Auto Swing Cancels timer Selects time Resets settings Sets clock 34 35 Specifications for FTKV Series Model name Capacity Power supply Running current Power consumption COP Indoor unit Front panel colour Airflow rate Fan speed Sound pressure levels Dimensions Machine weight Outdoor unit Casing colour Compressor Refrigerant Sound pressure levels Dimensions Machine weight Operation range Piping connection Max piping length Max level difference Indoor unit Outdoor unit Rated Min Max Rated H H L SL HxWxD kW Btu h W W m min cf
15. RTER gt 15 Inverter Advantages Less Temperature Flu Not cool TOO More Energy Saving than Non Inverter Inverters are devices which are able to vary their capacity by adjusting operating frequency Inverter air conditioners do this by altering the power supply frequency of their compressors In contrast non inverter air conditioners have a fixed capacity and can only control the indoor temperature by starting or stopping their COmpressors otart Number of rotations Controls rotation according to required power Inverter Large loss of electricity Non inverter Time Inverter systems can cut energy consumption compared to non inverter models This helps to reduce household power bills and also lowers CO2 emissions caused by electricity generation Set temp ctuation Inverter type Inverter air conditioners operate at maximum capacity as soon as they start up This burst of increased power allows them to reach the set temperature more quickly Energy Saving As the set temperature is reached inverter operation adjusts to low capacity to maintain the room temperature This precise control makes inverter models more energy efficient than non inverters which must repeatedly start or stop their compressors Non inverter type Diagram shows cooling operation Comfortable Inverter systems finely adjust their capacity according to the air conditioning load minimis ing t
16. The flat panel can also be easily removed for more thorough cleaning Comfort Control Indoor Unit Quiet Operation Indoor unit operating sound pressure levels can be decreased from the Low setting fan speed using the wireless remote controller gt See page 23 Outdoor Unit Quiet Operation Outdoor unit operating sound pressure levels can be decreased from the rated operation sound using the wireless remote controller This function is not available for RKC20 25 35 See page 23 EYE Intelligent Eye e Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room When there is no movement for 20 minutes it adjusts the temperature by approximately 2 C for energy savings This function is available for FTKV series gt See 19 Top view Side view 7m gt Programme Dry Function The microprocessor works to eliminate humidity while maintaining the most consistent temperature possible It automatically controls the temperature and fan speed Auto Fan Speed The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature 9 Timers 24 Hour On Off Timer This timer can start or stop the air conditioner within a 24 hour period It can be preset in 10 minute steps by pressing the On Off Timer button on the wireless remote controller The On Timer and Off Timer can be used in combination d
17. anced photocatalytic material with great adsorption power While a filters micron level fibres trap dust titanium apatite effectively adsorbs and decomposes bacteria The photocatalyst is activated simply by exposure to light This filter delivers consistent performance for approximately three years if it is washed with water once every six months This filter is not a medical device Benefits such as the adsorption and decomposition of bacteria are only effective for substances which are directly attached to the Titanium Apatite Photocatalytic Air Purifying Filter Anti Corrosion Treatment of Outdoor Heat Exchanger Fins he outdoor units heat exchanger fins are processed using a special anti corrosion treatment The surface is covered with a thin acrylic resin layer to provide enhanced resis tance to acid rain and salt corrosion Cross section of anti corrosion treated fin Hydrophilic film Aluminium Corrosion resistant acrylic resin n Heat exchanger Note 1 This practical application of titanium apatite was a world first Announced in September 2003 at the 3rd International Workshop on the Utilization and Commercialization of Photocatalytic Systems Coatings for Clean Surfaces Water and Air Purification 28 Function List of FIKV and Series Indoor Unit Models Functions DC Inverter Control ZTF Power Airflow Dual Flaps Mg ed Power Airflow Flap Wel Wide Angle L
18. ax level difference 12 20 Note The above values are based on operation with a 220 V 50 Hz power supply Measurement conditions 1 Cooling capacity is based on indoor temp 27 CDB 19 CWB outdoor temp 35 CDB piping length 7 5 m 2 Sound pressure levels are based on the temperature conditions 1 above These are anechoic conversion values These values are normally somewhat higher during actual operation as a result of ambient conditions 37 Options for Series Indoor Unit No Item FTKC20 25 35 1 5 room centralised controller 2 Wiring adaptor for time clock remote controller Normal open pulse contact normal open contact 3 Titanium apatite photocatalytic air purifying filter 4 Remote controller loss prevention with chain Notes 1 A wiring adaptor KRP413AB1S is also required for each indoor unit 2 The time clock and other devices should be obtained locally 3 The filter is a standard accessory 3 KAF970A46 KKF917A4 m Ub v 39 Cu 5 room centralised controller Titanium apatite photocatalytic Remote controller loss KRC72A air purifying filter prevention with chain KAF970A46 KKF917A4 Outdoor Unit No Item RKC20 25 35 1 Air direction adjustment grille KPW937B4 2 Drain plug D KKP937A4 Note 1 One set includes five pieces for five units F a C3 eee Air direction adjustment grille Drain plug KPW945A4 KKP937A4 Control System No ltem FTKC20 25 35 1 Central remote
19. ective operation no matter where the indoor unit is placed in a room gt See page 22 iN Vertical Auto Swing up and down d This function automatically moves the flaps up and down to distribute air across a room S Horizontal Auto Swing left and right Horizontal Auto Swing automatically moves the louvers to the left and right to cover a room with cool air This function is available for FTKV50 60 71 0 3D Airflow This function combines Vertical and Horizontal Auto Swing to circulate a cloud of cool air right to the corners of even large spaces The flaps and louvers swing in turn This function is available for FTKV50 60 71 gt See page 21 S e eA Comfort Airflow Mode This function prevents uncomfortable drafts from blowing directly on to the nam body To prevent drafts the flap moves upward during cooling operation This function is available for FTKV50 60 71 and FTKC20 25 35 gt See page 22 Cleanliness Titanium Apatite Photocatalytic Air Purifying Filter This filter contains the advanced photocatalytic material titanium apatite While the filter s micron level fibres trap dust this photocatalyst adsorbs and decomposes bacteria The filter can be used for up to three years with proper maintenance gt See pages 27 and 28 Wipe Clean Flat Panel Ea The flat panel design can be cleaned with only the single pass of a cloth across its smooth surface
20. eration when you go to bed z Bedroom Monday to Friday Programme 1 Programme 2 On Off 10 30 p m 2 00 a m Even if you go to bed at 11 00 p m the air conditioner will operate before 30 minutes to help you fall into a comfort able sleep Even if you go to will operate for into a comforta the night preve catching a chill bed at 11 00 p m the air conditioner another three hours to help you fall ble sleep Stopping operation during nts overcooling and saves you from Programme 3 Programme 4 On Off 6 00 a m 7 00 a m If you set the Weekly Timer 30 minutes before your wake up time you can avoid the hot and humid morning air and enjoy a pleasantly cool room as you get up The Weekly Timer will automatically stop operation when you leave home 26 Photocatalytic Air Purifying Air filter catches dust Titanium Apatite Photocatalytic Air Purifying Filter Effect of Titanium Apatite Photocatalyst Adsorbs Removes g Light Odours Bacteria Titanium Apatite Photocatalyst A Titanium Apatite Photocatalytic Air Purifying Filter Photocatalytic air purifying is a deodorising and antibacterial technology Daikin was the first to apply this advance to the air purifying filters used in air conditioners Daikin s success has led manufacturers in various industries to adopt the technology for antibacterial products Titanium apatite is an adv
21. essary to change the room temperature quickly gt See page 22 S Wireless Remote Controller with Backlight 9 The backlit LCD allows easy operation in the dark Frequently used functions are conveniently located on the front of the controller This function is available for FTKV series Indoor Unit On Off Switch The unit can be conveniently started by hand if the wireless remote controller is misplaced or its batteries are not charged Worry Free Auto Restart after Power Failure The air conditioner memorises the settings for operation mode cooling dry and fan only airflow temperature etc and automatically returns to them when power is restored after a power failure 7 Self Diagnosis with Digital Display SELF Malfunction codes are shown on the digital display panel of the wireless Y remote controller for fast and easy maintenance SC Anti Corrosion Treatment of Outdoor IO Heat Exchanger Fins The outdoor unit s heat exchanger fins are processed using a special anti corrosion treatment The surface is covered with a thin acrylic resin layer to enhance the fins resistance to acid rain and salt corrosion gt See page 28 Cross section of anti corrosion treated fin 7 Hydrophilic film Aluminium Corrosion resistant acrylic resin Heat exchanger fin Smile Curve The series features Daikin s new smile curve design for the front panel The smile curve creates a stylish
22. he difference between the set temperature and room temperature This ensures higher comfort levels than with non inverter systems 17 DC Inverter Advantages DC Inverter Control DC Inverter is Daikin s term for an inverter air conditioner equipped with a DC motor These motors use magnets to generate rotation making them more efficient than AC motors Daikin has fitted its advanced DC motors for compressors and fan motors with powerful neodymium magnets to achieve even greater efficiency It calls these devices Reluctance DC motors Reluctance DC motor CO More than AC motor 20 Reluctance DC motors are more efficient in the low frequency range commonly used by air conditioner compressors They are capable of improving efficiency by approximately 2096 Motor efficiency 96 N O 30 60 90 120 Rotational speed rps Swing Compressor With its smooth rotation the swing compressor significantly decreases friction and vibration It also eliminates the leakage of refrigerant gas during compression These advantages provide quiet and efficient operation Reluctance DC Motor for Compressors Reluctance DC motor Neodymium magnet The compressor is one of an air conditioners core components and its performance is directly linked to the motor Daikin was the first to successfully use a Reluctance DC motor with a scroll compressor in commercial use air conditioners
23. le not only the On and Off times but also to set temperatures Once you set up the Weekly Timer the air conditioner operates each day without controller input The Weekly Timer synchronises the air conditioner with your family s schedule greatly improving comfort in your home This function is available for the FTKV50 60 71 Controller Buttons and Copy Function You can set up the Weekly Timer using the wireless remote controller The copy function also enables a daily programme to be repeated on other days as required This makes it even easier to set the timer Deactivates reactivates or deletes Starts and completes settings Goes back Copies settings Goes next Selects timer mode setting significant number day time and temperature Living room Monday to Friday Programme 1 Programme 2 On Off 6 00 a m 8 00 a m If you set the Weekly Timer 30 minutes before your The Weekly Tim wake up time you can avoid the hot and humid morning after you leave air and enjoy a pleasantly cool room as you get up forget about the er will automatically stop operation home on a busy morning You can air conditioner Programme 3 Programme 4 On Off 6 00 p m 11 00 p m If you set the Weekly Timer an hour before you arrive home you can enjoy a wave of cool air aS soon as you step through the door The Weekly Timer will automatically stop op
24. m dB A mm kg Type Motor output W Type Charge kg H SL dB A HxWxD mm kg CDB Liquid Gas mm Drain m FTKV25NVMV RKV25NVMV 2 5 1 2 3 4 8 500 4 100 11 600 FTKV35NVMV FTKV50NVMV FTKV60NVMV RKV35NVMV RKV50NVMV RKVGONVMV 3 5 1 3 4 1 5 2 1 7 6 0 6 0 1 9 7 0 11 900 17 700 20 500 4 400 14 000 5 800 20 500 6 500 23 900 1 phase 220 240 V 50 Hz 1 phase 220 230 V 60 Hz NE 44 6 0 7A 540 910 1 300 1 580 4 63 3 85 4 00 3 80 FTKV25NVMV FTKV35NVMV FTKV50NVMV FTKV60NVMV Pure white 7 8 275 8 0 282 14 3 504 15 4 544 5 Steps quiet and automatic 37 25 22 38 26 23 43 34 31 45 35 32 283 x 800 x 195 290 x 1 050 x 250 9 12 RKV25NVMV RKV35NVMV RKV50NVMV RKV60NVMV Ivory white Hermetically sealed swing type 800 1 300 R 32 0 9 1 2 46 43 47 44 48 44 92 46 590 x 765 x 285 735 x 825 x 300 34 43 19 4 to 46 6 4 09 5 012 7 218 0 20 30 15 20 Note The above values are based on operation with a 220 V 50 Hz power supply Measurement conditions 1 Cooling capacity is based on indoor temp 27 CDB 19 CWB outdoor temp 35 CDB piping length 7 5 m 2 Sound pressure levels are based on the temperature conditions 1 above These are anechoic conversion values These values are normally somewhat higher during actual operation as a result of ambient conditions FTKV71NVMV RKV71NVMV 7 1 2 3 8 9 24 200 7 800 30 400 9 3 2 000 9 99 FTKV71NVMV 18 2 643 46 37 33 340 x 1 050 x 248 14 RKV
25. on This function circulates air to every part of a room for uniform cooling of even large spaces To start 3D Airflow push both the Vertical and Horizontal Auto Swing buttons The flaps and louvers swing in turn This function is available for the FTKV50 60 71 Comfort Airflow Mode Comfort Airflow Mode prevents uncomfortable drafts from blowing directly on to a person s body During cooling operation the flap moves upward to prevent cold drafts This function is available for FTKV50 60 71 and 20 25 35 The flaps and louvers swing in turn expanding the comfort zone 22 23 Quiet Nights in Your Neighbo urhood Indoor Unit Quiet Operation The FTKV and FTKC series give you a choice FTKV25 of 5 step Quiet or Automatic settings for the fan speed The Quiet setting selects Indoor Unit Quiet Operation which decreases the sound pressure level by 3 dB A below the Low setting This wide range of settings allows you to precisely control the fan speed according to your needs For example the Quiet function will help you to sleep more comfort ably at night The sound pressure level is just Fan speeds Sound pressure levels High H 37 dB A Low L 25 dB A v 3 dB A amp Quiet SL 22 dB A Auto SL L M H oo Q Q 22 dB A for the FTKV25 and FTKC25 Fan speed ou EE High Sound pressure level Outdoor Unit Quiet Operation This function dec
26. ouvers ANGLE 01 Vertical Auto Swing up and down 7 Horizontal Auto Swing left and right Comfortable Airflow lt 3D Airflow Le Comfort Airflow Mode Indoor Unit Quiet Operation E Intelligent Eye m Programme Dry Function Auto Fan Speed otandby Electricity Saving Econo Mode Inverter Powerful Operation Wireless Remote Controller with Backlight 7 Indoor Unit On Off Switch Comfort Control Lifestyle Convenience z Titanium Apatite Photocatalytic Air Purifying Filter Cleanliness Wipe Clean Flat Panel 24 Hour On Off Timer wo Weekly Timer Night Set Mode Auto Restart after Power Failure SELF self Diagnosis with Digital Display Timers Worry Free Outdoor Unit Models Functions Comfort Control Outdoor Unit Quiet Operation Worry Free Anti Corrosion Treatment of Outdoor Heat Exchanger Fins 29 FTKC20 25 35 RKC20 25 35 31 Functions Comfortable Airflow zzz Power Airflow Dual Flaps The Power Airflow Dual Flaps can flatten out during cooling operation to DUAL deliver cool air to the corners of a room This function is available for FTKV series and FTKC50 60 gt See page 21 Power Airflow Flap The Power Airflow Flap flattens out during cooling operation to deliver cool air to the corners of a room This function is available for FTKC20 25 35 Wide Angle Louvers The Wide Angle Louvers provide wide airflow coverage for eff
27. ow Patterns Power Airflow Dual Flaps Wide Angle Louvers The Power Airflow Dual Flaps flatten out during cooling operation to deliver air to every part of a room Select The Wide Angle Louvers provide effective airflow coverage no matter where the ing the low angle sends air right to the corners while choosing the high angle spreads air around the centre indoor unit is placed in a room The louvers deliver cool air right to the corners of This function is available for the FTKV series and FTKC50 60 any space The FTKV50 60 71 be adjusted directly For FTKC20 25 35 the Power Airflow Flap is available from the wireless remote controller Other units can be set manually The louvers cover even a spacious room The angles of the louvers can be freely adjusted according to where people are in the room If the indoor unit is not positioned in the centre of the wall the louvers can be set to the left or right When you choose the low angle cool air slides off to reach the corners of the room Inverter Powerful Operation 20 Inverter Powerful Operation boosts airflow to maxi minutes mum volume for a 20 minute period This function is convenient for quickly adjusting the indoor temperature to the set temperature After 20 minutes the unit automatically returns to its previ ous settings 3D Airflow 3D Airflow combines Vertical and Horizontal Auto Swing to reduce indoor temperature fluctuati
28. reases the sound pressure level by 3 to 6 dB A below the rated operation It provides a sound pressure level of 43 dB A for the RKV25 Capacity may decrease when Outdoor Unit Quiet Operation is selected This function is not available for RKC20 25 35 Each decrease in airflow volume reduces the sound pressure level RKV25 Operations Sound pressure levels Rated 46 dB A v dB y Quiet SL 43 dB A 22 dB A is so quiet you can even hear whispers Indoor unit Outdoor unit Rustling of leaves Pendulum of a wall clock Ps 4 0 hy 5 0 Library Normal office Night Set Mode Pressing the Off timer button automatically selects Night Set Mode This function prevents excessive cooling for a pleasant Sleep One hour after the Off timer button is pressed the room temperature is raised by 0 5 C Set temp before l Cooling Off timer begins to operate e Time i A 60 minutes A Off timer turns on Off timer stops air conditioner Cooling operation Room temperature is raised by 0 5 C after 60 minutes Notes 1 This value is for operation at 220 V 50 Hz 2 Based on Examples of Sound Pressure Levels Ministry of the Environment Japan November 2002 24 25 set and Forget On Off Opera tion Weekly Timer The Weekly Timer allows up to four actions to be programmed for each day of the week It is possible to schedu
29. tioners are well known for their precise control In fact their outstanding efficiency can cut energy bills compared to non inverter models This precision also means greater comfort plus full power at the touch of a button With its strong environmental commitment Daikin has been using its market leading position to promote inverter systems worldwide DC Inverter models feature advanced DC motors These motors use high power magnets to generate rotation giving them greater efficiency than AC motors Features Improved performance over non inverter models Optimal control with Intelligent Eye and Econo Mode Advanced comfort features including 3D Airflow Greater convenience with weekly scheduling Titanium Apatite Photocatalytic Air Purifying Filter su FTKV25 35 H5 Smile Curve The FTKC series features Daikin s new smile curve design for the front panel mm The smile curve creates a stylish modern appearance which blends easily with any interior decor FTKC20 25 35 4 Smile Curve 11 Lineup of FTI KV Series FTKV Series FTKV25 35NVMV e RKV25 35NVMV INVERTER D FTKV25NVMV RKV25NVMV Cooling Capacity Min Max Btu h 8 500 4 100 11 600 FTKV35NVMV RKV35NVMV Rated KW 3 5 1 3 4 1 Cooling Capacity Min MaX Btu h 11 900
30. uropiean style of FTKJ series proves once again that design is everything Yet this elegant body also houses cutting edge smart technology which provides outstanding comfort and performance in any situation he series also delivers Daikin s well known energy efficiency thanks to features such as its redesigned swing compressors This versatile system truly is a total solution for designers architects and home owners alike Energy saving COP of 3 59 to 4 81 otylish finish in eye pleasing colours Wide selection of comfort technologies Whisper quiet sound level Remote control from mobile devices White Silver German Design Award red award 2014 SPECIAL i MENTION 2015 winner Urusara Contents of FTKV and Series Model name Indoor unit FTXZ25 REXZ35 FTXZ50 Outdoor unit RXZ25 RXZ35 RXZ50 Rated kW 2 45 0 6 3 9 3 45 0 6 5 3 4 95 0 6 5 8 1 Cooling Min Max Btu h 8 400 2 000 13 300 11 800 2 000 18 100 16 900 2 000 19 800 Capacity Rated kW 3 6 0 6 7 5 5 0 0 6 9 0 6 3 0 6 9 4 Bub Btu h 12 300 2 000 25 600 17 100 2 000 30 700 21 500 2 000 32 100 Ma be o bs PO its Time for DC Inverter P21 Cooling Rated 430 110 880 680 110 1 330 1 150 110 1 600 Power consumption Min Max Heating 620 100 2 010 1 000 100 2530 1 410 100 2 640 Indoor unit FTXZ25 EIXZ35 FTXZ50 Dimensions HxWx

Download Pdf Manuals

image

Related Search

Related Contents

KORG MS2000  Geopolitique_version finale  LISTE DES TITRES DISPONIBLES - Bibliothèque de l`INSA de Rouen  JVC 0809DTSMDTJEIN User's Manual  SPEEDLINK Sensor Bar for Wii™  Untitled - CableOrganizer.com  Descarga  TAP100 User Manual  

Copyright © All rights reserved.