Home
PoE Industrial Ethernet Extender IVC
Contents
1. 2 Tighten the wire clamp screws for preventing the wires from loosing 3 5 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires the PoE Industrial Ethernet Extender will detect the fault status of the power failure and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts 1 The wire gauge for the terminal block should be in the range between 12 24 AWG 2 Alarm relay circuit accepts up to 30V max 3A currents 21 _ 3 6 Mounting Installation This section describes how to install the PoE Industrial Ethernet Extender and make connection to it Please read the following topics and perform the procedures in the order being presented In the installation steps below this Manual use IGS 801 PLANET 8 Port Industrial Gigabit Switch as the example However the steps for PLANET Industrial Switch amp Industrial Media Converter are similar 3 6 1 Install DIN Rail Mounting The DIN Rail is screwed on the PoE Industrial Ethernet Extender when out of factory Please refer to following figures to hang the PoE Industrial Ethernet Extender on track Step 1 Lightly press the button of DIN Rail into the track 1322 Step 2 Check the DIN Rail is tightly on th
2. _ VDS i rx PoE IP Camera i O PoE IP Camera IVC 2004PT PoE Wireless AP PoE IP Phone BNC 2 4km RJ 11 1 4km Figure 3 2 IVC 2004PT BNC and RJ 11 Connection With 4 PoE in line power interfaces the PoE Industrial Ethernet Extender can build a power central controlled IP phone system IP camera system AP group for the enterprise For instance 4 camera AP can be easily installed around the corner in the company for surveillance demands or build a wireless roaming environment in the offices Without the power socket limitation it makes the installation of cameras or WLAN AP more easily and efficiently 17 1 Data Power PoE IP Camera Q Power Line DC Telephone wire Ww 2 4GHz 802 11n IVC 2004PT DIN Rail Power Supply PoE VoIP ATA I T 05 299 E o 27 3 4A Phone PoE VoIP Phone PoE Wireless AP Datac Power Figure 3 3 IVC 2004PT PoE Connection IVC 2004PT temperature range is from 40 to 75 Degree C which can handle any harsh environment and places It also compatibles with PLANET IVC 2002 VC 201A and VC 202A Without spend extra cost to deploy a new local Internet in apartment hotel campus and hospitality environment It can use the original network structure to re deploy with our latest product PLANET IVC 2004PT For example MC 700 MC 1500 and MC 1500R chassis with VC 201A and VC 202A inside and set it as CPE Custom
3. DC for Non PoE Devices Redundant power with polarity reverse protection function Power Consumption Dissipation 66 4 Watts 226BTU Max PoE 5 64 Watts 19 24BTU Non PoE Installation Standard Conformance DIN Rail Kit and Wall Mount Ear Stability testing IEC60068 2 32 Free Fall IEC60068 2 27 Shock IEC60068 2 6 Vibration Operating Temperature 40 75 C Storage Temperature 40 85 C Operating Humidity 10 to 90 relative humidity non condensing Storage Humidity 10 to 90 relative humidity non condensing Regulation Compliance FCC Part 15 Class A CE Standards Compliance IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE 802 3af Power over Ethernet IEEE 802 3x Full Duplex Pause frame Flow Control ITU T e G 997 1 e G 993 1 VDSL e G 993 2 VDSL2 Profile 17a 1 BNC and RJ 11 mode must switch to the same position for Master and Slave Otherwise it may cause unstable 2 The actual data rate will vary on the quality of the copper wire and environment factors 3 If power source is lower than 48V DC the 802 3af PoE function will not be activated However it will not influence the VDSL2 and 4 ports TP operation 2 Hardware Description m IVC 2004PT The IVC 2004PT provides 4 RJ 45 with PoE 1 RJ 11 and 1 BNC port for network line connection The 4 RJ 45 ports with two different running speeds 10Mbps and 100Mbps It wi
4. representative established within the EU Authorized representative established within the EU if applicable Company Name Planet Technology Corp Company Address 11F No 96 Min Chuan Road Hsin Tien Taipei Taiwan R O C Person responsible for making this declaration Name Surname Kent Kang Position Title Product Manager f feng Taiwan 22 Oct 2010 Place Date Legal Signature PLANET TECHNOLOGY CORPORATION e mail sales planet com tw http www planet com tw 11F No 96 Min Chuan Road Hsin Tien Taipei Taiwan R O C Tel 886 2 2219 9518 Fax 886 2 2219 9528
5. A Max 15 4 Watts Output PoE Pin Assignment 1 2 3 6 10Base T 2 pair UTP Cat 3 4 5 up to 100m 328ft Ethernet e 100Base TX 2 pair UTP Cat 5 5e 6 up to 100m 328ft Cabling Twisted pair telephone wires AWG24 or better Xo up to 1 HM BNC 50 ohm RG58A U RG58C U RG58 U and 75 ohm RG6 Distance 2 4km Asymmetric Mode VDSL RJ 11 BNC 200m gt 99 63Mbps 400m gt 91 48Mbps 600m gt 71 32Mbps 800m gt 53 18Mbps 200m gt 99 65Mbps 400m gt 99 64Mbps 600m gt 97 59Mbps 800m 94 51Mbps Performance Down Stream Up Stream 1000m 38 8Mbps 1200m 33 5Mbps 1400m 28 2Mbps 1000m 84 45Mbps 1200m 73 37Mbps 1400m 61 28Mbps 1600m 54 20Mbps 1800m 48 13Mbps 2000m 39 9Mbps 2200m 35 6Mbps 2400m 31 4Mbps Symmetric Mode VDSL RJ 11 BNC 200m 91 99Mbps 400m 74 79Mbps 600m 54 51Mbps 800m 38 34Mbps 1000m 27 21Mbps 1200m 24 15Mbps 1400m 21 10Mbps 200m gt 95 99Mbps 400m 92 97Mbps 600m 81 82Mbps 800m 71 70Mbps 1000m 60 57Mbps 1200m 50 44Mbps 1400m 42 33Mbps 1600m 37 27Mbps 1800m 29 22Mbps 2000m 23 21Mbps 2200m 19 17Mbps 2400m 19 13Mbps Vv V Vv 9 1 Dimensions H x W x D 135mm x 87 8mm x 50mm Weight 631g Power Requirement 48V DC for PoE Devices 12 36V
6. PoE Industrial Ethernet Extender IVC 2004PT User s Manual Trademarks Copyright PLANET Technology Corp 2011 Contents subject to revision without prior notice PLANET is a registered trademark of PLANET Technology Corp The information in this manual is subject to change without notice All other trademarks belong to their respective owners Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications and makes no warranty and representation either implied or expressed with respect to the quality performance merchantability or fitness for a particular purpose PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is subject to change without notice and does not represent a commitment on the part of PLANET PLANET assumes no responsibility for any inaccuracies that may be contained in this User s Manual PLANET makes no commitment to update or keep current the information in this User s Manual and reserves the right to make improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incomplete we would appreciate your comments and suggestions FCC Warning This equipment has been tested and
7. e PoE Industrial Ethernet Extender consists one terminal block connector within two DC power inputs Figure 2 2 shows the upper panel of the PoE Industrial Ethernet Extender 0000000000000 0000000000000 0000000000000 0000000000000 oon nooooo OO0oooccoo 0000 OO 0000 Vi Vi p V2 Vie Input p L pcasv PWRI Faut PWR2 Figure 2 2 PoE Industrial Ethernet Extender Upper Panel 3 Installation 3 1 Install PoE Industrial Ethernet Extender IVC 2004PT The PoE Industrial Ethernet Extender does not require any software configuration Users can immediately use any feature of this product simply by attached the cables and plug power on There is some key limitation on the PoE Industrial Ethernet Extender Please check the following items IVC 2004PT The device is used for Point to Point connection only Master device to Slave device and has equipped with one RJ 11 and one BNC connector for VDSL2 network connection Telephone Wire Depending on the quality of telephone line the maximum distances of RJ 11 segment is 1 4km 4593ft with AWG 24 telephone wires Coaxial Depending on the quality of coaxial cable the maximum distance of BNC segment is 2 4km 7874ft with 5C type of coaxial cable The link distances and performance will vary on the quality of telephone wire and coaxial cable 15 1 3 2 IVC 2004PT BNC RJ 11 Proper Connection PLANET PoE Indu
8. e track Step 3 Please refer to following procedures to remove the PoE Industrial Ethernet Extender from the track Step 4 Lightly press the button of DIN Rail for remove it from track 23 1 3 6 2 Wall Mount Plate Mounting To install the PoE Industrial Ethernet Extender on the wall please follows the instructions described below Step 1 Remove the DIN Rail from the PoE Industrial Ethernet Extender loose the screws to remove the DIN Rail Step 2 Place the wall mount plate on the rear panel of the PoE Industrial Ethernet Extender Step 3 Use the screws to screw the wall mount plate on the PoE Industrial Ethernet Extender Step 4 Use the hook holes at the corners of the wall mount plate to hang the PoE Industrial Ethernet Extender on the wall Step 5 To remove the wall mount plate reverse steps above 4 Troubleshooting SYMPTOM VDSL LNK LED does not light after wire is connected to the VDSL port CHECKPOINT 1 Verify the length of the wires connected between two IVC 2004PT extenders not more than 2 4km for BNC and 1 4km for RJ 11 connections Please also try to adjust the DIP switch of IVC 2004PT to other SNR mode 2 Please note that you must use one IVC 2004PT with Master mode and the other IVC 2004PT with Slave mode SYMPTOM TP LED does not light after cable is connected to the port CHECKPOINT 1 Verify you are using the Cat 5 5e or 6 cables with RJ 45 connector to con
9. er Premises Equipment mode which placed in the wiring center MDF room On the other hand connects an IVC 2004PT extender with Master mode by using telephone line or coaxial cable 100Base TX UTP with PoE 100Base TX UTP sm VDSL Coaxial Cable mm VDSL2 Telephone Wire Figure 3 4 IVC 2004PT Application Topology When deciding where to put the IVC 2004PT then you must ensure It is accessible and cables can be connected easily Cabling is away from sources of electrical noise such as radios transmitters and power lines and fluorescent lighting fixtures Avoid the Water or moisture to reach the IVC 2004PT Air Flow around the unit and through the vents in the side of the case is not restricted company recommend that you provide a minimum of 25mm inch clearance To prolong the operational life of your units Do not place objects on top of any unit or stack 19 1 3 4 Wiring the Power Inputs The 6 contact terminal block connector on the top panel of PoE Industrial Ethernet Extender is used for two DC redundant powers input Please follow the steps below to insert the power wire 1 Insert positive negative DC power wires into the contacts 1 and 2 for POWER 1 or 5 and 6 for POWER 2 OOOOOOO0 OOOOOOO Vi Vie yy V2 V2 Input L 1 pcasv PWR1 Fault PWR2 Vi Vi V2 V2 Must input 48V DC power source to make PoE function workable
10. found to comply with the regulations for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WEEE Warning To avoid the potential effects on the environment and human K health as a result of the presence of hazardous substances in iai electrical and electronic equipment end users of electrical and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately Revision PoE Industrial Ethernet Extender User s Manual For Model IVC 2004PT Rev 1 1 January 2011 Part No 2350 AH0350 001 Table Of Contents TREFOAUCUON eer T 5 WD CHECK IStaieatusedscccdctirsdasnssaceacne xci ors esel 5 1 2 Ethernet over VDSL2 Br
11. idge Description ssssssssessrsresersesreree 5 1 3 Cile m 7 1 4 SpecificallOns iecore sesta ene i anaa SDN FEL EE 8 Hardware DescriptiOn nite cire reete Deere a R Renee a 11 2 1 Front Panel cse trist paexichedar sea EUR UON TA En 11 2 1 1 LED indicators for IVC 2004PT souise ieda 12 2 1 2 DIP Switch Indication eee edes aE 13 2 2 The Upper Panel orto inre struere wesenivndencatersademmehcesienss 14 Installation 155 eon rinnova hana ea Era a Ir su Ino n 43 snes sevens o bunken 15 3 1 Install PoE Industrial Ethernet Extender IVC 2004PT 15 3 2 IVC 2004PT BNC RJ 11 Proper Connection 16 3 3 IVC 2004PT Application Connection sssssesessssssresesererenenao 17 3 4 Wiring the Power InpUts 0 ee rores ren e ped ra ana o 20 3 5 Wiring the Fault Alarm Contact seeee 21 3 6 MOUNTING Install tion isu usmmagfasnmeeeie tettet 22 3 6 1 Install DIN Rail MOUNTING sissies idua 22 3 6 2 Wall Mount Plate Mounting eee 24 TROUDIGSHOOUNG ER 25 1 Introduction 1 1 Checklist Check the contents of your package for following parts The PoE Industrial Ethernet Extender x1 User s Manual x1 DIN Rail Kit Wall Mount Kit If any of these items are missing or damaged please contact your dealer immediately if possible retain the carton including the original packing material and use them against to repack the product in case there is a need to retu
12. ll distinguish the speed of incoming connection automatically This section describes the hardware features of the PoE Industrial Ethernet Extender For easier control of the PoE Industrial Ethernet Extender familiarize yourself with its display indicators and ports Front panel illustrations in this chapter display the unit LED indicators Before connecting any network device to the PoE Industrial Ethernet Extender read this chapter carefully 2 1 Front Panel The units front panel provides a simple interface monitoring the PoE Industrial Ethernet Extender E IVC 2004PT Front Panel 4 IVC 2004PT Figure 2 1 IVC 2004PT Front Panel 2 1 1 LED indicators for IVC 2004PT On the front panel of rich diagnostic LEDs provide the operating status of individual port E System LED Color Function P1 Green Light Indicate the power 1 has power P2 Green Light Indicate the power 2 has power FAULT Green Light Indicate the either power 1 or power 2 has no power B VDSL BNC LED Color Function Light Indicate that the VDSL link is established ACT Green Indicate that the VDSL link is actively Blink sending or receiving data over that port Light Indicate that the VDSL link is established Fast Indicate that the VDSL link is at training Sync Green Blink status about 10 seconds Slow i Indicate that the VDSL link is at idle status Blink Indicate the VDSL B
13. nder by designated frequency bands for the transmis sion of upstream and downstream signals User has the ability to select fixed band plan When Symmetric is selected that provides better downstream performance when Asymmetric is selected that provides better upstream performance 27 1 Q PLANET Networking amp Communication EC Declaration of Conformi For the following equipment Type of Product Industrial Ethernet Extender with 4 Port PoE 1 BNC RJ 11 4 Port 10 100TX PoE 17a Profile 40 75 DegreeC Model Number IVC 2004PT Produced by Manufacturer s Name Planet Technology Corp Manufacturer s Address 11F No 96 Min Chuan Road Hsin Tien Taipei Taiwan R O C is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on 2004 108 EC For the evaluation regarding the EMC the following standards were applied Emission EN 55022 Class A 2006 Harmonic EN 61000 3 2 2006 Flicker EN 61000 3 3 1995 A1 2001 A2 2005 Immunity EN 55024 1998 A1 2001 A2 2003 ESD IEC 61000 4 2 2001 RS IEC 61000 4 3 2008 EFT Burst IEC 61000 4 4 2004 Surge IEC 61000 4 5 2005 CS IEC 61000 4 6 2008 Magnetic Field IEC 61000 4 8 2001 Voltage Disp IEC 61000 4 11 2004 Responsible for marking this declaration if the X Manufacturer O Authorized
14. nect to the port 2 If your device like LAN card supports Auto Negotiation please try to modify at a fixed speed of your device by manually 3 Check the extender and the connected device s power are ON 4 Check the cables are firmly seated in its connectors in the switch and in the associated device 5 Check the connecting cables are good 6 Check the power adapter is functional including the connecting device SYMPTOM VDSL sometimes will re chain and unstable CHECKPOINT 1 Verify what connection type of the cable is using BNC or RJ 11 cable 2 Check the Master CO and Slave CPE DIP 2 are switch to the same and correct mode 25 1 5 FAQ Q1 A1 Q2 A2 Q3 A3 Q4 A4 Q5 A5 What is the IVC 2004PT power input 48V DC for PoE function and 12 to 36V DC for Non PoE function What is VDSL2 VDSL2 Very High Bit Rate Digital Subscriber Line 2 G 993 2 is the newest and most advanced standard of xDSL broadband wire line communications Designed to support the wide deployment of Triple Play services such as voice data high definition television HDTV and inter active gaming VDSL2 enable operators and carrier to gradually flexibly and cost efficiently upgrade exiting xDSL infrastructure What is the best distance for IVC 2004PT In order to guarantee the stability and better quality of network so we would suggest the distance within 1 4 kilometer is the best f
15. oE Industrial Ethernet Extender with IP 30 Aluminum metal shape for easily deployment in Heavy Industrial demanding environments PLANET PoE Industrial Ethernet Extender provides a lower cost replacement and smooth migration for existing Long Reach Ethernet LRE networks The cable specifications of the connection are listed as following 10Base T Category 3 4 or 5 UTP 100Base TX Category 5 5e or 6 UTP Ethernet over VDSL2 Twisted pair Telephone Wires Ethernet over VDSL2 Coaxial Cable Slave device CPE must connect to Master device CO through the telephone wire or coaxial cable It is not allow connecting like Master to Master or Slave to Slave To define the IVC 2004PT to Master or Slave please refer to section 2 1 2 for more detail 1 3 Key Features The PoE Industrial Ethernet Extender provides the following key features 4 x Ports IEEE 802 3af Power over Ethernet Standard Each of PoE port provides 15 4 Watts Compatible with IVC 2002 VC 201A and VC 202A 17a Profile Cost effective VDSL2 Master Slave bridge solution via DIP Switch e Selectable BNC and RJ 11 mode for the data transmission 40 to 75 Degree C operating temperature Redundant Power Design 12V 48V DC redundant power with polarity reverse protect function IP 30 Aluminum metal case Protection Defines Asymmetric Band Plan 998 and Symmetric band plans for the transmission of Upstream and D
16. or RJ 11 Connecting and 2 4 kilometer for BNC Connecting What is the best data rate for IVC 2004PT Link Type amp RJ 11 Telephone Wire BNC Coaxial Cable Distance DIP Mode 200m 1400m 200m 2400m Asymmetric 99 63Mbps 28 2Mbps 99 65Mbps 31 4Mbps Symmetric 91 99Mbps 21 10Mbps 95 99Mbps 19 13Mbps Can IVC 2004PT compatible with VC 201A VC 202A YES IVC 2004PT profile 17a and VC 201A VC 202A profile 17a are base on ITU T G 993 2 VDSL2 with same Profiles so far they are compatible with each other Q6 A6 Q7 A7 What is SNR and what s the effect In analog and digital communications Signal to Noise Ratio often written SNR is a measure of signal strength relative to back ground noise The ratio is usually measured in decibels dB In digital communications the SNR will probably cause a reduction in data speed because of frequent errors that require the source transmitting computer or terminal to resend some packets of data SNR measures the quality of a transmission channel over a network channel The greater the ratio the easier it is to identify and subsequently isolate and eliminate the source of noise Generally speaking the higher SNR value gets better line quality but lower performance What is band plan and what s the effect VDSL2 defines multiple band plans and configuration modes profiles to allow asymmetric and symmetric services in the same bi
17. ownstream signals Complies with IEEE 802 3 IEEE 802 3u and IEEE 802 3x standards DMT Discrete Multi Tone line coding Half Duplex Back Pressure and IEEE 802 3x Full Duplex Pause Frame Flow Control Support up to 1536 bytes packet size 802 1Q VLAN tag transparent Integrated address look up engine support 2K absolute MAC addresses VDSL2 Stand Alone transceiver for simple bridge modem application Selectable Target Band Plan and Target SNR Margin Support extensive LED indicators for network diagnostics DIN Rail and Wall Mount Design 74 1 4 Specifications Product IVC 2004PT Hardware Specification 10 100 Base TX 4 x RJ 45 Auto Negotiation and Auto MDI MDI X PoE 4 x PoE Port1 Port4 Ports 1 x RJ 11 female Phone Jack yest 1 x BNC female connector DIP Switch 4 position DIP switch Functionality t Master Slave mode select Selectable BNC and RJ 11 mode Selectable target Band Plan Selectable target SNR mode Encoding VDSL DMT ITU T G 997 1 ITU T G 993 1 VDSL ITU T G 993 2 VDSL2 Profile 17a Support LED Indicators P1 Green P2 Green Fault Green Master Green and Slave Green ACT Green Sync Green PoE Orange Power Over PoE Standard IEEE 802 3af Power over Ethernet PSE PoE Type End Span EOS 48V DC power input source Input FOE NEC 48V DC Per Port 350m
18. ridge is running at Master Green Light Mastermode Indicate the VDSL Bridge is running at Slave Green Light Stave node m 10 100Base TX with PoE Port LED Color Function Light Indicate that the port is link up LNK Indicate that the Extender is actively ACT Green Blink sending or receiving data over that port Off Indicate that the port is link down PoE Indicate the port is providing 48V DC In Use Orange Light in line power 1 4 ports 2 1 2 DIP Switch Indication The PoE Industrial Ethernet Extender provides 4 selective transmission modes By switching the transmission modes you can obtain a best transmission mode to suit with phone line or BNC quality of distance connectivity The following is the summary table of transmission setting bandwidth and distance extensibility tested for AWG 24 0 5mm twisted pair without noise and cross talk DIP Switch DIP 1 DIP 2 DIP 3 DIP 4 Function Mode Link Type Band Plan SNR OFF Master RJ 11 Symm 9dB ON default Slave BNC Asymm 6dB W Master Salve Master Central Office the Master device mode usually the Master device will be located at the data center of ISP or enter prise to link to the backbone Slave Customer Premises Equipment the Slave device mode usually the Slave device will be located at branch office home or remote side as the long reach data receiver The Sla
19. rn it to us for repair 1 2 Ethernet over VDSL2 Bridge Description PLANET s state of the art Ethernet over VDSL2 products are based on two core networking technologies Ethernet and VDSL2 Very high data rate Digital Subscriber Line 2 This technology offers the absolute fastest possible data transmission speeds over existing copper telephone lines or coaxial cables without the need for rewiring The IVC 2004PT PoE Industrial Ethernet Extender has a switching architecture with 4 PoE of RJ 45 10 100Mbps ports and Asymmetric or Symmetric Ethernet over VDSL port Asymmetric means upstream and downstream rate are not the same and Symmetric means upstream and downstream rate are similar the VDSL port can be RJ 11 or BNC Connector The IVC 2004PT can set to Master or Slave mode via a DIP switch When IVC 2004PT RJ 11 is connected with other IVC 2004PT device the performance will up to 99 63Mbps for asymmetric data rate within 200m and up to 28 2Mbps at 1 4km The IVC 2004PT BNC performance is up to 99 65Mbps for asymmetric data rate within 200m and up to 31 4Mbps at 2 4km This capability is ideal for use as an Ethernet extender for your existing Ethernet network 5 F With 4 PoE interfaces the IVC 2004PT will be the ideal for small business and workgroups requiring to deploy the PoE for the wireless access points IP based surveillance camera or IP phones in any places easily efficiently and cost effective The IVC 2004PT P
20. strial Ethernet Extender has a DIP switch which can adjust to be Master or Slave mode Connection of two PLANET PoE Industrial Ethernet Extenders one must be Master CO mode and the other one must be Slave CPE mode Please refer to the following Figure 3 1 chart PoE Industrial Ethernet Extender does not allow connecting BNC and RJ 11 at the same time Coaxial Cable Connections 2 4km Max DIP 2 must switch to the BNC mode PoE IP camera 4 No Connection gt gt Rl RJ 45 Connections 100m 328ft Max LI Ethernet Switch RJ 45 Connections 100m 328ft Max Master IVC 2004PT Slave IVC 2002 PoE IP camera mu Telephone Wire Connections 1 4km Max Ethernet Switch DIP 2 must switch to the RJ 11 mode RJ 45 Connections 100m 328ft Max RJ 45 Connections 100m 328ft Max Master IVC 2004PT Slave IVC 2002 gr VDSU Coaxial Cable RdEHE VDSL Telephone Wire 9 1 1 1 1 100Base TX UTP with PoE 1 1 100Base TX UTP Figure 3 1 Industrial Ethernet Extender BNC and RJ 11 Connection Chart 316 3 3 IVC 2004PT Application Connection Two PoE Industrial Ethernet Extenders could be used to link two different Area networks Through the normal telephone line or coaxial cable it could setup 99 63Mbps RJ 11 or 99 65Mbps BNC asymmetric backbone B 100Base TX UTP with PoE 100Base TX UTP m
21. ve also can be connected to the PC IP Camera or Wireless Access Point When the PoE Industrial Ethernet Extender operates at Slave mode the DIP switch 2 3 and 4 are no function W Link Type BNC mode allows IVC 2004PT to connect and data transfer by using BNC cable RJ 11 mode allows IVC 2004PT to connect and data transfer by using Telephone Wire 13 1 E Band Plan User can switch the Band Plan either Symmetric or Asymmetric by their own When Symmetric is selected that provides better upstream performance when Asymmetric is selected that provides better downstream performance Refer to table above for details E Target SNR Signal Noise Ratio Margin When fixed SNR margin is selected the system will maintain the SNR margin at 9 dB across all usable loop length 1 By default setting the four DIP switch at ON Link type both of IVC 2004PT must switch to the position and operate as Slave For operate as Master please adjust the DIP 1 switch to OFF position Adjust other DIP switch setting to fill different network application demand same position otherwise it may cause unstable For example if want to connect both of IVC 2004PT through BNC cable the Master CO and Slave CPE must switch the DIP 2 at BNC mode Please power off the PoE Industrial Ethernet Extender before making any transmission mode adjustment 2 2 The Upper Panel The upper panel of th
Download Pdf Manuals
Related Search
Related Contents
S-Stage KIT(88cc)取扱説明書 User Manual - Covera for Wi-Fi site survey and coverage simulation Transmitter Calibration 必要書類 1 申請書 様式第1号 2 明細書 案内図も併用 3 収支精算書 4 FOX - RF2 プレート式熱交換器 取扱説明書 biggest s2s Manual Cobra Digital PR230VP User's Manual Installation Instructions – SAS & Evap Kit Mod. 04005 Copyright © All rights reserved.
Failed to retrieve file