Home
DP2XX Series Displays Technical Information Manual
Contents
1. P200 135 Suggested mounting procedure callouts Callout Description 1 Hole for panel mounting Gasket seal area Panel thickness 2 to 5 mm 0 079 to 0 197 in Panel seal Panel bracket aA unt PP wl N Four screws Mounting screw placement P200 134 L1026202 Rev BA May 2014 27 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX installation and start up Fastening Caution e Use of non recommended screws may cause damage to housing e Excessive torque force may cause damage to housing Maximum torque 0 9 Nm e Reassembly with self tapping screws may damage existing threads in housing Fastening procedure mm in A o O O 101 20 0 30 3 98 0 01 A aste Fl C ig Y AS y le 106 2 0 3 4 18 0 01 P200 131 Fastening procedure callouts Callout Description 1 Fastening hole depth 11 mm 0 43 in May be threaded M3 and used with standard screws 28 L1026202 R
2. Pin9 Not used Not used DIN AIN DIN AIN DIN AIN CAN Low Pin 10 Multi Input Multi Input Multi Input Multi Input Multi Input Pin 11 Multi Input Multi Input Multi Input Multi Input Multi Input Pin 12 Buzzer Out Buzzer Out Buzzer Out Buzzer Out Buzzer Out Multifunction inputs include the following software configurable inputs DIN AIN FreqIN Rheo 4 20mAIN Model type DP250 05 01 05 05 00 DP250 06 01 04 05 01 DP250 06 01 05 05 01 DP250 01 01 04 05 02 DP250 01 01 05 05 02 Model 11077443 11060816 11077444 11091448 11094414 number Pin1 Power Ground Power Ground Power Ground Power Ground Power Ground Pin2 Power Supply Power Supply Power Supply Power Supply Power Supply Pin3 CAN 0 High CAN 0 High CAN 0 High CAN 0 High CAN 0 High Pin 4 CAN 0 Low CAN 0 Low CAN 0 Low CAN 0 Low CAN 0 Low Pin5 A CAN Shield AIN CAN Shield AIN CAN Shield AIN CAN Shield AIN CAN Shield Pin 6 DIN AIN RedCAN 0 High RedCAN 0 High DIN AIN DIN AIN Pin7 DIN AIN RedCAN 0 Low RedCAN 0 Low DIN AIN DIN AIN Pin 8 DIN AIN 5V REFOUT DIN AIN 5V REFOUT DIN AIN 5V REFOUT DIN AIN DIN AIN CAN 1 High CAN 1 High CAN 1 High Pin 9 DIN AIN DIN AIN DIN AIN DIN AIN DIN AIN CAN 1 Low CAN 1 Low CAN 1 Low Pin 10 Multi Input Multi Input Multi Input Multi Input Multi Input Pin 11 Multi Input Multi Input Multi Input Multi Input Multi input Pin 12 Buzzer out
3. Rev BA May 2014 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX model variants DP210 model variants continued DP211 model variants Real Time Clock RTC Yes Yes Low Temp 40 C 40 F 40 C 40 F Functionality LTF Flash 2MB 2MB Application key No Yes Application log 2MB 2MB USB USB device in front USB device in front Ingress Protection IP IP 54 IP 54 ratingt Mounting bracket Yes Yes User manual No No Buzzer output Yes Yes Engine Information No Yes Control EIC software RedCAN relays No No Installation manual Yes Yes Multifunction inputs include the following software configurable inputs DIN AIN FreqIN Rheo 4 20mAIN t The USB cover must be in place for full IP 54 protection DP210 models are recommended for in cab use only DP211 model variants Model type DP211 04 01 02 04 01 DP211 04 01 03 04 01 Model number 11134226 11134227 Screen size 96 5 mm 3 8 in 96 5 mm 3 8 in Inputs outputs 2 CAN i 2 CAN 2 Multi 2 Multi Real Time Clock RTC Yes Yes Low Temp 40 C 40 F 40 C 40 F Functionality LTF Flash 2MB 2MB Application key Yes Yes Application log 2MB 2MB Control EIC software USB USB device in front USB device in front Ingress Protection IP IP 54 IP 54 rating Mounting bracket Yes Yes User manual No No Buzzer output Yes
4. 1 GUIDE Software User Manual Operation Manual 10100824 Technical Information TI A TI is comprehensive information for engineering and service personnel to reference Data Sheet DS A DS is summarized information and parameters that are unique to a specific model API Specifications API An API is specifications for programming variable settings API specifications are the definitive source of information regarding pin characteristics PLUS 1 GUIDE Software User Manual This user operation manual OM details information regarding the PLUS 1 GUIDE software tool set that is used to build PLUS 1 applications This OM covers the following broad topics How to use the GUIDE graphical application development tool to create machine applications How to configure module input and output parameters How to configure module input and output parameters How to download GUIDE applications to target PLUS 1 hardware modules How to upload and download tuning parameters How to use the PLUS 1 service tool Latest version of technical literature Up to date technical literature is available at www powersolutions danfoss com 4 L1026202 Rev BA May 2014 Denpi Technical Information PLUS 1 Mobile Machine Displays DP2XX Series User liability and safety statements OEM responsibility The OEM of a machine or vehicle in which Danfoss products are installed has the full responsibility for all conseque
5. Buzzer out Buzzer out Buzzer out Buzzer out Multifunction inputs include the following software configurable inputs DIN AIN FreqIN Rheo 4 20mAIN USB mini b connector 12345 P200 129 Pin assignments Pin1 Vbus Pin 2 D L1026202 Rev BA May 2014 15 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX connectors Pin assignments continued Pin 3 D Pin4 NC Pin5 GND USB functionality is intended only for use with the PLUS 1 GUIDE Service Tool application USB use is supported in PLUS 1 GUIDE Service Tool versions 4 0 and later Binder Series 702 USB connector ONO oy P200 130 Pin assignments Pin1 USB Device Vbus output Pin2 USB Device D Pin3 USB Device D Pin 4 USB Device GND Pin5 Not Used Pin 6 Not Used Pin 7 Not Used Pin 8 Not Used 16 L1026202 Rev BA May 2014 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX input output types and specifications Input types e Digital or Analog DIN AIN e Multifunction Digital or Analog or Frequency or Rhelostat or 4 20 mA Din AIN FreqIN Rheo 4 20 mAIN Analog or Temperature or Rheostat AIN Temp Rheo e Fixed Range Analog or CAN shield AIN CAN shield Each PLUS 1 Module input pin supports one of the above functional types For pins with multiple functions input configurations are use
6. PLUS 1 controller 12 Sensor lines should be twisted about one turn every 10 cm 4 in 13 It is better to use wire harness anchors that will allow wires to float with respect to the machine rather than rigid anchors 14 Electronic modules should be grounded to a dedicated conductor of sufficient size that is connected to the battery ng guidelines Remove electronic components from the machine before any arc welding The following is recommended when welding on a machine equipped with electronic components L1026202 Rev BA May 2014 29 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX installation and start up Limiting crosstalk Visibility and viewing radius e Turn the engine off e Disconnect the negative battery cable from the battery e Do not use electronic components to ground the welder e Clamp the ground cable for the welder to the component that will be welded as close as possible to the weld Due to the general characteristics of the grayscale DP2XX series graphical display the display may contain faint shadow like images This is called crosstalk a common occurrence in LCD displays Crosstoalk is a result of pixel interference due to the constraints of the LCD design Crosstalk is very pattern dependent It may or may not occur it is dependent on the actual images used and the placement of the images within the display If multiple grayscale images are used ens
7. Yes Engine Information No Yes L1026202 Rev BA May 2014 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX model variants DP211 model variants continued RedCAN relays No No Installation manual Yes Yes Multifunction inputs include the following software configurable inputs DIN AIN FreqIN Rheo 4 20mAIN t The USB cover must be in place for full IP 54 protection DP211 models are recommended for in cab use only DP250 model variants DP250 model variants Model type DP250 00 00 04 00 00 DP250 00 01 05 00 00 DP250 01 01 04 05 00 DP250 01 01 05 05 00 DP250 05 01 04 05 00 Model number 11080686 11075899 11075900 11077442 11060814 Screen size 88 9 mm 3 5 in 88 9 mm 3 5 in 88 9 mm 3 5 in 88 9 mm 3 5 in 88 9 mm 3 5 in Inputs outputs 1 CAN port 1 CAN 1 CAN 1 CAN 2 CAN 2 Multi 2 Multi 4 DIN AIN 4 DIN AIN 2 DIN AIN 2 Multi 2 Multi 2 Multi or 1 CAN 4 DIN AIN 2 Multi Real Time Clock No Yes Yes Yes Yes RTC Low Temp 20 C 4 F 30 C 22 F 30 C 22 F 30 C 22 F 30 C 22 F Functionality LTC Flash 16MB 16MB 16MB 16MB 16MB Application key No Yes No Yes No Application log No No 16MB 16MB 16MB USB No No No No No Ingress IP 67 IP 67 IP 67 IP 67 IP 67 Protection IP rating Mounting bracket Yes Yes Yes Yes Yes User manual No Yes No Yes No Buzzer output Yes Yes Y
8. current A 2 Short circuit current peak A 8 Saturation voltage V 1 At1A Current measurement A 0 2 Current measurement mA 60 OA error 75 TA CAN DP200 DP210 DP211 Description Unit Minimum Maximum Typical Comment Available Baud rates kbps 0 01 100 111 111 With 120 O termination 125 250 500 1000 Maximum input V 0 36 voltage range L1026202 Rev BA May 2014 21 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX input output types and specifications CAN RedCAN DP250 Description Unit Minimum Maximum Typical Comment Available Baud rates kbps 0 01 100 111 111 With 120 O termination 125 250 500 1000 Maximum input V 0 70 voltage range 22 L1026202 Rev BA May 2014 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX ratings Electronic components environmental testing criteria Climate environment Description Applicable standard Comment Storage temperature EC 60068 2 1 test Ab IEC 60068 2 2 test Bb Operating temperature EC 60068 2 1 test Ab IEC 60068 2 2 test Bd Thermal cycle EC 60068 2 2 test Na IEC 60068 2 38 partial Humidity EC 60068 2 78 IEC 60068 2 30 test Db Damp heat steady state and cyclic Degree of protection EC 60529 Chemical e
9. multifunction inputs Code Description 00 1 CAN port 01 1 CAN port 4 DIN AIN 02 1 RedCAN port 03 1 RedCAN port 2 DIN AIN 04 2 CAN ports 05 User configurable 2 CAN 2 DIN AIN or 1 CAN port 4 DIN AIN 06 User configurable 1 RedCAN port 1 CAN port or 1 RedCAN port 2 2 DIN AIN C Real Time Clock RTC Low Temperature Functionality LTF Code Description 00 No RTC and LTF 01 RTC and LTF D Flash memory application key allows download of Danfoss proprietary applications and blocks Code Description 02 2MB without application key 03 2MB with application key 04 16MB without application key 05 16MB with application key 6 L1026202 Rev BA May 2014 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX overview E Application log Code Description 00 None 04 2MB 05 16MB F USB port type Code Description 00 None 01 USB device in front 02 USB device in rear L1026202 Rev BA May 2014 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX model variants DP200 model variants DP200 model variants Model type DP200 00 00 02 00 DP200 00 01 03 00 DP200 01 01 02 00 DP200 01 01 03 00 DP200 04 01 02 00 DP200 04 01 03 00 00 00 00 00 00 00 Model number 1010
10. 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed All trademarks in this material are property of the respective companies Danfoss and the Danfoss logotype are trademarks of Danfoss A S All rights reserved L1026202 Rev BA May 2014 www danfoss com Danfoss A S 2014
11. 7021 10107380 10106883 10107381 10107022 10107382 Screen size 96 5 mm 3 8 in 96 5 mm 3 8 in 96 5 mm 3 8 in 96 5 mm 3 8 in 96 5 mm 3 8 in 96 5 mm 3 8 in Inputs outputs 1 CAN 1 CAN 1 CAN 1 CAN 2 CAN 2 CAN 2 Multi 2 Multi 4 DIN AIN 4 DIN AIN 2 Multi 2 Multi 2 Multi 2 Multi Real Time No Yes Yes Yes Yes Yes Clock RTC Low Temp 20 C 4 F 40 C 40 F 40 C 40 F 40 C 40 F 40 C 40 F 40 C 40 F Functionality LTF Flash 2MB 2MB 2MB 2MB 2MB 2MB Application No Yes No Yes No Yes key Application No No No No No No log USB No No No No No No Ingress IP 67 IP 67 IP 67 IP 67 IP 67 IP 67 Protection IP rating Mounting Yes Yes Yes Yes Yes Yes bracket User manual No Yes CD No No No No Buzzer output Yes Yes Yes Yes Yes Yes Engine No Yes No Yes No Yes Information Control EIC software RedCAN relays No No No No No No Installation Yes Yes Yes Yes Yes Yes manual Multifunction inputs include the following software configurable inputs DIN AIN FreqIN Rheo 4 20mAIN DP210 model variants discontinued article DP210 model variants discontinued article replaced by DP211 see DP211 model variants on page 9 DP210 model variants Model type DP210 04 01 02 04 01 DP210 04 01 03 04 01 Model number 10106884 10107383 Screen size 96 5 mm 3 8 in 96 5 mm 3 8 in Inputs outputs 2 CAN i 2 CAN 2 Multi 2 Multi L1026202
12. DP2XX input output types and specifications Multifunction input ranges Resistance input Description Unit Minimum Maximum Typical Comment Resistance range kQ 0 10 Input resistance kQ 1 33 Pull up to 5 V Resistance error Q 1 R 0kQ 201 R 10kO Current input Description Unit Minimum Maximum Typical Comment Current range 0 25 DP200 and DP210 Shut off at 28 mA DP211 and DP250 Shut off at 50 mA Input resistance Q 100 2 0 V at 20 mA input current Current error mA 0 1 lin OmA 33 08 lin 20 mA There can be problems with overload when using these inputs together with some sensors When some sensors are powered up a significant amount of current is used to charge capacitors in the sensor This causes the internal protection circuitry to disconnect and give status overload The overload status cannot be reset from the display software This is due to the fact that the protection circuit is done in hardware and once disconnected it is continually in overload To recover the current input needs to be disconnected or grounded The protection circuit is for preventing terminal damage to the resistor which is used to measure the current The DP2XX buzzer output which is an NPN output can be used to ground the current input and create a reset of the overload situation This output needs to be extern
13. Mobile Machine Displays DP2XX Series DP2XX input output types and specifications Low level analog input Description Unit Minimum Maximum Typical Comment Voltage range V 0 5 5 Input resistance kQ 233 No pullup down 14 With pull up to 5 V 14 Pull down to ground 73 With pull up and pull down to 5 V Analog voltage error mV 7 Uin 0V 107 Vin 5V Bandwidth kHz 12 High level multifunction inputs High level digital input Description Unit Minimum Maximum Typical Comment Voltage range V 0 70 Input resistance kQ 105 No pullup down 13 With pull up to 5 V 13 Pull down to ground 7 With pull up and pull down to 5 V Programmable low V 0 70 threshold voltage Programmable high V 0 70 threshold voltage Rise time us 10 Fall time us 10 High level analog input Description Unit Minimum Maximum Typical Comment Voltage range V 0 70 Input resistance kQ 105 No pullup down 13 With pull up to 5 V 13 Pull down to ground 7 With pull up and pull down to 5 V Analog voltage error mV 100 Uin 0V 300 mV Uin x 3 4 2700 Uin 70V Bandwidth kHz 13 L1026202 Rev BA May 2014 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series
14. Pare Technical Information PLUS 1 Mobile Machine Displays DP2XX Series powersolutions danfoss com Hi Technical Information PLUS 1 Mobile Machine Displays DP2XX Series Revision history Table of revisions Date Changed Rev May 2014 Converted to Danfoss layout DITA CMS Various updates BA March 2010 First edition AA L1026202 Rev BA May 2014 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series Contents DP2XX literature references Technical Information TIGE Ee eg GE GR ee Ek Ee Ee ee Ge en eg ee ee ee Ge see 4 Data Sheet DS 4 N der te ie ee Go EE Ee 4 PLUS 1 GUIDE Software User Manual c cscsssssssssssssssssesssessesssessssssesssessesssesssessssssesssesssessssssessscssecsscsasesssessessscssecssesasesssesseess 4 Latest version of technical literature sesse ee ee ee ee ee ER eek ee ee ee eek eek ee ee ER ee eek ee ek eek ee gee ek ee eek 4 User liability and safety statements ld VEG een lol EE EE EE EE EE EE 5 DP2XX overview PLUS 1 Mobile Machine DisplayS sssccsssscssssssccssscsssssesssseccsseessnsscesatecssnsesecusecssnseessnecesuseessnsesesuecssnsesecnsecesaeeessneeeenseesse 6 Productnamind converiti issie eg Se Eg Ek ak GR ER Rg n ei ER ee Ge eon ede GER ek eg GEE 6 DP2XX model variants DP200 mOCel HE DRR OE EE EE RE EE N OE 8 DP210 model variants discontinued article ecsssscccsseccssesecsseeccssssess
15. aes 23 Supply voltage maximum current FAthNGS csseesccccsssessecsssessecessnessecssseesecssssecsessssecsessssssesesssnscsessnssecssessseeessenseesesensseeeesees 23 Ingress Protection IP rating on seen seek ek ee eek Ge Reen Ge Roe dek ee ee eR ee Gee ee Roe GER Geek Gee Ge ee Gee ee Bee 25 DP2XX installation and start up DIMENSIONS EE N N A leke ia ie EE N RE EE N ETT Fastening EO RE EE EE Display operation guidelines Recommended machine wiring QUIdeliNeS sssccssseccssecsssessccssecsseeesssteccssseecssnesesssecsssuseccssecsssseeessuecessueecssueeesnseesssueenses 29 Electronic components welding guidelines 1 29 Limiting crosstalk 30 Visibility and viewing radiuz 30 Display faulty application reCOVETY sssscssssccsnsscssssecssseesssnsecssssesssusecsssecessusecssuecessuesessecssuesssuecssnsesesueessueeessneessenecssneees 30 L1026202 Rev BA May 2014 3 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX literature references Reference literature Literature title Literature type Literature number DP2XX Series PLUS 1 Mobile Machine Displays Technical Information L1026202 DP200 Series PLUS 1 Mobile Machine Displays Data Sheet 11025041 DP210 Series PLUS 1 Mobile Machine Displays Data Sheet 11041319 DP211 Series PLUS 1 Mobile Machine Displays Data Sheet L1426132 DP250 Series PLUS 1 Mobile Machine Displays Data Sheet L1026137 PLUS
16. ally wired to the current sensor input The buzzer output cannot be used for anything else when used for reset of overload on current sensor input Frequency input Description Unit Minimum Maximum Typical Comment Frequency range kHz 0 10 Positive duty input Description Unit Minimum Maximum Typical Comment Positive duty cycle 0 01 100 range Count input Description Unit Minimum Maximum Typical Comment Count range Count s 0 65536 Ouad count input Description Unit Minimum Maximum Typical Comment Count range Count s 0 3276 8 20 L1026202 Rev BA May 2014 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX input output types and specifications CAN Shield and analog 5 V only inputs ranges Alarm output CAN RedCAN communication CAN Shield Description Unit Minimum Maximum Typical Comment Input impedance 1uFH1O Analog input 5 V only Description Unit Minimum Maximum Typical Comment Voltage range V 0 5 5 Input resistance kQ 233 Analog voltage error mV 7 Uin 0V 20 mV Uin x 1 6 107 Uin 5V Bandwidth kHz 2 8 Alarm output Description Unit Minimum Maximum Comment Current A 0 1 Short circuit
17. erse polarity protection DC supply current circuit board mA 215 380 Ubat 9V only 130 219 UBat 14V 70 121 UBat 28V 40 75 Ubat 63V Heater W 3 6 when on DP250 heater current consumption is 5 at 0 C 32 F temperature dependent 10 at 40 C 40 F Power supply interruption without ms 30 34 According to ISO 7637 2 rebooting 35 36 55 46 140 100 Load dump protection 28V systems V 200 According to ISO 7637 2 pulses cycle time 100 s criteria C 3 ms 200 ms 10 Auto heater shut off CCF Auto over temp protection heater shuts off when not needed 5 V reference output V Minimum 4 75 Maximum 5 25 5 V reference output Description Unit Minimum Maximum Output voltage V 4 75 5 25 Output current A 0 5 Output short circuit A 1 Short circuit protection V 0 70 USB input output parameters Description Unit Minimum Typical Maximum Comment 2 0 full speed Mbit s 12 Vbus input voltage Volt 75 5 25 Vbus input resistance kQ 3 6 47 Short circuit protection oo V 0 70 damage Vbus output voltage 75 5 25 Vbus output current 5 Vbus short current 1 24 L1026202 Rev BA May 2014 Pat Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX ratings Ingress Protection IP rating DP2XX displays except USB in front model carry a full Ingress Protecion rating of IP 67 only if the rear USB matin
18. es Yes Yes Engine No Yes No Yes No Information Control EIC software RedCAN relays No No No No No Multifunction inputs include the following software configurable inputs DIN AIN FreqIN Rheo 4 20mAIN DP250 model variants Model DP250 05 01 05 05 00 DP250 06 01 04 05 01 DP250 06 01 05 05 01 DP250 01 01 04 05 02 DP250 01 01 05 05 02 Part number 11077443 11060816 11077444 11091448 11094414 Screen size 88 9 mm 3 5 in 88 9 mm 3 5 in 88 9 mm 3 5 in 88 9 mm 3 5 in 88 9 mm 3 5 in 10 L1026202 Rev BA May 2014 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX model variants DP250 model variants continued Inputs outputs 2 CAN 1 RedCAN 1 RedCAN 1 CAN port 1 CAN port 2 DIN AIN 1 CAN 1 CAN 2 Multi 2 Multi 2 Multi 2 Multi 2 Multi 4 DIN AIN 4 DIN AIN or or or 1 CAN 1 RedCAN 1 RedCAN 4 DIN AIN 2 DIN AIN 2 DIN AIN 2 Multi 2 Multi 2 Multi Real Time Clock Yes Yes Yes Yes Yes RTC Low Temp 30 C 22 F 30 C 22 F 30 C 22 F 30 C 22 F 30 C 22 F Functionality LTF Flash 16MB 16MB 16MB 16MB 16MB Application key Yes No Yes No Yes Application log 16MB 16MB 16MB 16MB 16MB USB No USB device in front USB device in front USB device in rear USB device in rear Ingress IP 67 IP 54 IP 54 IP 67 IP 67 Protection IP rating Mounti
19. ev BA May 2014 Para Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX installation and start up Display operation guidelines e Disconnect your machine s battery power before connecting power and signal cables to the display e Before doing any electrical welding on your machine disconnect all power and signal cable cables connected to the display e Donot exceed the display power supply voltage ratings Using higher voltages may damage the display and can create a fire or electrical shock hazard Donot use or store the display where flammable gases or chemicals are present Using or storing the display where flammable gases or chemicals are present may cause an explosion e Software configures the keypad buttons on the display Do not use these buttons to implement critical safety features Use separate mechanical switches to implement critical safety features such as emergency stops e Design systems that use the display so that a communication error or failure between the display and other units cannot cause a malfunction that might injure people or damage material e The protective glass over the display screen will break if hit with a hard or heavy object Install the display to reduce the possibility of it being hit by hard or heavy objects Storing or operating a display in an environment that exceeds the display specified temperature or humidity rating may damage the display Always clea
20. g connector or seal plug is in place DP2XX displays with a front mini USB option carry a full Ingress Protecion rating of IP 54 only if the USB mating connector or seal plug cover is in place L1026202 Rev BA May 2014 25 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX installation and start up Dimensions mm in 41 50 1 63 32 50 1 27 I 4 Paces H 7 mm N 57 00 2 08 a 109 00 4 33 y y 25 00 0 98 113 00 4 52 gt 1 34 00 1 33 Callout Callout Description 1 Universal Serial Bus USB Mounting Caution Oversized panel cutouts may jeopardize product IP rating Caution Excessive screw torque force can cause damage to housing Maximum torque 0 9 Nm 26 L1026202 Rev BA May 2014 P200132 Denpi Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX installation and start up Suggested mounting procedure mm in Le 115 9 4 56 gt g ____105 5 0 7 4 15 0 02 os le 82 4 3 24 gt ry A 111 4 4 39 EP 100 5 0 7 Z 3 96 0 03
21. hine Displays DP2XX Series DP2XX input output types and specifications High digital analog inputs High level digital input Description Unit Minimum Maximum Typical Comment Voltage range V 0 70 Input resistance kQ 105 No pullup down 13 With pull up to 5 V 13 Pull down to ground 7 With pull up and pull down to 5 V Programmable low V 0 70 threshold voltage Programmable high V 0 70 threshold voltage Rise time us 10 Fall time HS 10 High level analog input Description Unit Minimum Maximum Typical Comment Voltage range V 0 70 Input resistance kQ 105 No pullup down 13 With pull up to 5 V 13 Pull down to ground 7 With pull up and pull down to 5 V Analog voltage error mV 100 Uin 0V 300 mV Uin x 3 4 2700 Uin 70V Bandwidth kHz 13 Low level multifunction inputs Low level digital input Description Unit Minimum Maximum Typical Comment Voltage range V 0 5 5 Input resistance kQ 233 No pullup down 14 With pull up to 5 V 14 Pull down to ground 7 3 With pull up and pull down to 5 V Programmable low V 0 5 5 threshold voltage Programmable high V 0 55 threshold voltage Rise time us 10 18 L1026202 Rev BA May 2014 Technical Information PLUS 1
22. ile Hydraulics Steering Go to www powersolutions danfoss com for further product information e Electrohydraulics e Hydraulic Power Steering Wherever off highway vehicles are at work so is Danfoss e Integrated Systems We offer expert worldwide support for our customers ensuring the best possible solutions for outstanding performance And with an extensive network of Global Service Partners we also provide e Joysticks and Control Handles Microcontrollers and Please contact the Danfoss Power Solution representative nearest you Software Open Circuit Axial Piston Pumps Orbital Motors e PLUS 1 GUIDE Proportional Valves Sensors Steering Transit Mixer Drives Comatrol www comatrol com Local address Schwarzmiiller Inverter www schwarzmueller inverter com Turolla www turollaocg com Valmova www valmova com Hydro Gear www hydro gear com Daikin Sauer Danfoss www daikin sauer danfoss com Danfoss Danfoss Power Solutions US Company Power Solutions GmbH amp Co OHG 2800 East 13th Street Krokamp 35 Ames IA 50010 USA D 24539 Neum nster Germany Phone 1 515 239 6000 Phone 49 4321 871 0 comprehensive global service for all of our components Power Solutions ApS Nordborgvej 81 DK 6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New District Shanghai China 201206 Phone 86
23. ion PLUS 1 Mobile Machine Displays DP2XX Series DP2XX connectors DP200 connectors Pin assignments Deutsch DTM06 12 connector a NO O O NO O wO OO KO 0 WMO 5 NO oo 2200B Model type DP200 00 00 02 00 DP200 00 01 03 00 DP200 01 01 02 00 DP200 01 01 03 00 DP200 04 01 02 00 DP200 04 01 03 00 00 00 00 00 00 00 Model number 10107021 10107380 10106883 10107381 10107022 10107382 Pin1 Power Ground Power Ground Power Ground Power Ground Power Ground Power Ground O Pin2 Power Supply Power Supply Power Supply Power Supply Power Supply Power Supply Pin3 CAN 0 High CAN 0 High CAN 0 High CAN 0 High CAN 0 High CAN 0 High Pin4 CAN 0 Low CAN 0 Low CAN 0 Low CAN 0 Low CAN 0 Low CAN 0 Low Pin5 AIN AIN AIN AIN AIN AIN CAN Shield CAN Shield CAN Shield CAN Shield CAN Shield CAN Shield Pin6 not used not used DIN AIN DIN AIN not used not used Pin7 not used not used DIN AIN DIN AIN not used not used Pin 8 not used not used DIN AIN DIN AIN CAN 1 High CAN 1 High Pin9 not used not used DIN AIN DIN AIN CAN 1 Low CAN 1 Low Pin 10 Multi input Multi input Multi input Multi input Multi input Multi input Pin 11 Multi input Multi input Multi input Multi input Multi input Multi input Pin 12 Buzzer out Buzzer out Buzzer out Buzzer out Buzzer out Buzzer out Multifunction inputs incl
24. n the display with a soft damp cloth Use a mild dishwashing detergent as needed To avoid scratching and discoloring the display do not use abrasive pads scouring powders or solvents such as alcohol benzene or paint thinner e Danfoss graphical displays are not user serviceable Return the display to the factory in case of failure Recommended machine wiring guidelines Electronic components weldi 1 All wires must be protected from mechanical abuse Wires should be run in flexible metal or plastic conduits 2 Use 85 C 185 F wire with abrasion resistant insulation 105 C 221 F wire should be considered near hot surfaces 3 Use a wire size that is appropriate for the module connector 4 Separate high current wires such as solenoids lights alternators or fuel pumps from sensor and other noise sensitive input wires 5 Run wires along the inside of or close to metal machine surfaces where possible This simulates a shield which will minimize the effects of EMI RFI radiation 6 Do not run wires near sharp metal corners Consider running wires through a grommet when rounding a corner 7 Do not run wires near hot machine members 8 Provide strain relief for all wires 9 Avoid running wires near moving or vibrating components 10 Avoid long unsupported wire spans 11 All analog sensors should be powered by the sensor power source from the PLUS 1 controller and ground returned to the sensor ground pin on the
25. nces that might occur Danfoss has no responsibility for any consequences direct or indirect caused by failures or malfunctions e Danfoss has no responsibility for any accidents caused by incorrectly mounted or maintained equipment Danfoss does not assume any responsibility for Danfoss products being incorrectly applied or the system being programmed in a manner that jeopardizes safety e All safety critical systems shall include an emergency stop to switch off the main supply voltage for the outputs of the electronic control system All safety critical components shall be installed in sucha way that the main supply voltage can be switched off at any time The emergency stop must be easily accessible to the operator L1026202 Rev BA May 2014 5 Devt Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX overview PLUS 1 Mobile Machine Displays PLUS 1 Mobile Machine Displays are designed to provide flexible expandable powerful and cost effective total machine management system displays for a wide variety of vehicle applications Product naming convention DP2XX model code bel TOCO LOLOL This is not a variant configurator A Model name Code Description DP200 Grayscale graphical display DP210 Grayscale graphical display with USB DP211 Grayscale graphical display with USB DP250 Color graphical display B Inputs ouputs all models have two
26. ng bracket Yes Yes Yes Yes Yes User manual Yes No Yes No No Buzzer output Yes Yes Yes Yes Yes Engine Yes No Yes No Yes Information Control EIC software RedCAN relays No Yes Yes No No Multifunction inputs include the following software configurable inputs Related products Connector bag assemblies DIN AIN FreqIN Rheo 4 20mAIN 10102025 Deutsch Mating Connector Bag Assembly solid 20 24 AWG 10100944 Deutsch Mating Connector Bag Assembly stamped 16 20 AWG 10103497 Binder Connector and Cable Kit Series 702 Connection tools 10100744 Deutsch stamped contacts terminal crimp tool size 20 10100745 Deutsch solid contacts terminal crimp tool Mounting kits 10107354 Mounting hardware kit for DP200 DP250 without USB DP250 with USB in rear L1026202 Rev BA May 2014 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX model variants Mounting kits continued 10107264 Mounting hardware kit for DP210 DP211 DP250 with USB in front 11079236 Optional panel mounting kit for All models Software 10101000 PLUS 1 GUIDE Application Software Including Service Tool and Screen Editor Online J1939 CAN EIC Engine Monitor Software Requires a model with Application Key See Product naming convention on page 6 for model codes 12 L1026202 Rev BA May 2014 Technical Informat
27. nvironment Description Applicable standard Comment Salt mist IEC 60068 2 58 test Kb Chemical resistance ISO 16750 5 Mechanical environment Description Applicable standard Comment Vibration IEC 60068 2 6 test Fc IEC6008 2 64 test Fh Bump IEC 60068 2 29 test Eb Shock IEC 60068 2 27 test Ea Free fall IEC 60068 2 32 test Ed Electrical electromagnetic Description Applicable standard Comment EMC emission SO 13766 SAE J1113 13 Electromagnetic compatibility for earth moving machinery EMC immunity SO 13766 Electromagnetic compatibility for earth moving machinery Electrostatic discharge EN 60 1 000 4 2 Auto electrical transients ISO 7637 2 ISO 7637 3 Short circuit protection Danfoss test Inputs and outputs survive continuous short circuit Normal function resumes when short is removed Reversed polarity Danfoss test Survives reverse polarity at supply voltage protection for at least five minutes Supply voltage maximum current ratings DP2XX graphical displays are designed to operate with a nominal 9 to 63 Vdc power supply with reverse polarity protection L1026202 Rev BA May 2014 23 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX ratings Supply voltage Description Unit DP200 DP210 DP250 Comment DP211 DC supply voltage Volt 9 to 36 9 to 63 With rev
28. owing software configurable inputs DIN AIN FreqIN Rheo 4 20mAIN USB mini b connector 12345 P200 129 Pin assignments Pin1 Vbus Pin 2 D Pin 3 D Pin 4 NC Pin5 GND USB functionality is intended only for use with the PLUS 1 GUIDE Service Tool application USB use is supported in PLUS 1 GUIDE Service Tool versions 4 0 and later Deutsch DTM06 12 connector O NO O wO OO AO 0 vO O O 12 1 NO o0 i 2200B Model type DP250 00 00 04 00 00 DP250 00 01 05 00 00 DP250 01 01 04 05 00 DP250 01 01 05 05 00 DP250 05 01 04 05 00 Model number 11080686 11075899 11075900 110770442 11060814 Pin 1 Power Ground Power Ground Power Ground Power Ground Power Ground Pin2 Power Supply Power Supply Power Supply Power Supply Power Supply Pin3 CAN 0 High CAN 0 High CAN 0 High CAN 0 High CAN 0 High Pin4 CAN 0 Low CAN 0 Low CAN 0 Low CAN 0 Low CAN 0 Low 14 L1026202 Rev BA May 2014 Para Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX connectors Pin assignments continued Pin5 AIN CAN Shield AIN CAN Shield AIN CAN Shield AIN CAN Shield AIN CAN Shield Pin6 Not used Not used DIN AIN DIN AIN DIG AIN Pin7 Not used Not used DIN AIN DIN AIN DIG AIN Pin 8 Not used Not used DIN AIN DIN AIN DIN AIN 5V REFOUT CAN High
29. procedure 30 L1026202 Rev BA May 2014 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX installation and start up 1 Connect the USB cable to the PC and the unit 2 Start the service tool and select the display as the communication gateway 3 Depress the leftmost and the rightmost push button before the unit is powered af N Ne 4 Apply power to the unit with the push buttons depressed Q LRU G P200 136 P200 137 5 Release the push buttons when the LED above the USB receptacle is lit The unit will now stay to execute the boot loader and allow the application program to be replaced P200 138 L1026202 Rev BA May 2014 31 Products we offer Danfoss Power Solutions is a global manufacturer and supplier of high quality hydraulic and electronic components We specialize in providing state of the art technology and solutions that Bent Axis Motors excel in the harsh operating conditions of the mobile off highway market Building on our extensive Closed Circuit Axial Piston Pumps and Motors applications expertise we work closely with our customers to ensure exceptional performance for a broad range of off highway vehicles We help OEMs around the world speed up system development reduce costs and bring vehicles to e Displays market faster Electrohydraulic Power Danfoss Your Strongest Partner in Mob
30. r programmable using PLUS 1 GUIDE templates The DP2XX series graphical displays do not have a Real Time Operating System RTOS Do not use the display as the master control for any type of safety critical control or closed loop control system Frequency inputs are managed by the operating system Avoid using these inputs for any type of Safety Critical closed loop control as the accuracy may be affected by processor load DP2XX displays should only be used for non safety critical related functions Low level digital analog inputs Low level digital input Description Unit Minimum Maximum Typical Comment Voltage range V 0 5 5 Input resistance kQ 233 No pullup down 14 With pull up to 5 V 14 Pull down to ground 73 With pull up and pull down to 5 V Programmable low V 0 5 5 threshold voltage Programmable high V 0 5 5 threshold voltage Rise time us 10 Fall time us 10 Low level analog input Description Unit Minimum Maximum Typical Comment Voltage range V 0 5 5 Input resistance kQ 233 No pullup down 14 With pull up to 5 V 14 Pull down to ground 73 With pull up and pull down to 5 V Analog voltage error mV 20 Uin 0V 107 UVin 5V Bandwidth kHz 12 L1026202 Rev BA May 2014 17 Technical Information PLUS 1 Mobile Mac
31. sessesseccsnecesssecssascessuesesnseessaseessuecssneeesnseessaseessae 8 BERE nee AE ED OR EN DE EE N 9 DP250 model variant sessscsssccsssssccssssssssescssneccssuseccsussessseesssusecssnscessuecessuseessusecsssscessuecsssuseccsseeessusesssuseessasecesueeessneceesusecesneessne 10 Related PrOCUCES EE N EE ER EEN 11 DP2XX connectors BP keel gie RE AE 13 DP210 and DP211 COMMECTOSS cssssscccsssccssssccsseccssseecessesecssecsssuseccsnecssssscsssucessusesssuseessuecessusecsssecessueessuscessasecesusecssneeessaseessnees 13 Died Ta el N EE EE EE EE EE N N GENRES RAAY 14 DP2XX input output types and specifications BUDE LY RE EA AR EE EE EE 17 Low level digital analog RT OR 17 High Gig ital AMalOgiMPUts c ssccscssscsssesstascessecsneszsensasseasnenasseoeststcessnvaddseeedsauseasurnnsseqedGanubesevadssenedsasszevnensseczod ausdenciaissenedgasasonguadaee 18 Low level multifunction NT 18 High level multifunction INPUTS eeecsssesccsseeccssesccsseeccsseecssseecsssscesssecsssuscecsuscessueesssuscessuecsssusecssueceesueeessneesssueesssueessseessauseesse 19 Multifunction input ranges CAN Shield and analog 5 V only inputs rarnges sesecssssccssseessseecsssseccsnsecesneesssueccsuecessuseessneceesueeessueeeesueecssuseccaneesennseeses 21 Alarm Te IT CAN RedCAN communication DP2XX ratings Electronic components environmental testing Criteria seeecssssccsssescsseecesssecssnssesssecsssuseecsseecesseeessuecessueecsentecesseesss
32. ude the following software configurable inputs DIN AIN FreqIN Rheo 4 20mAIN Above pinouts are for device pins Use care when wiring mating connector DP210 and DP211 connectors Deutsch DTM06 12 connector G 23739 O OO OO O 1211109 87 2200B Pin Assignments Model type DP210 04 01 02 04 01 DP210 04 01 03 04 01 DP211 04 01 02 04 01 DP211 04 01 03 04 01 Model 10106884 10107383 11134226 11134227 number Pin1 Power Ground Power Ground Power Ground Power Ground Pin 2 Power Supply Power Supply Power Supply Power Supply Pin3 CAN 0 High CAN 0 High CAN 0 High CAN 0 High L1026202 Rev BA May 2014 Technical Information PLUS 1 Mobile Machine Displays DP2XX Series DP2XX connectors DP250 connectors Pin assignments Pin Assignments continued Pin4 CAN 0 Low CAN 0 Low CAN 0 Low CAN 0 Low Pin5 AIN CAN Shield AIN CAN Shield AIN CAN Shield AIN CAN Shield Pin6 Not used Not used Not used Not used Pin 7 Not used Not used Not used Not used Pin 8 CAN 1 High CAN 1 High CAN 1 High CAN 1 High Pin 9 CAN 1 Low CAN 1 Low CAN 1 Low CAN 1 Low Pin 10 Multi Input Multi Input Multi Input Multi Input Pin 11 Multi Input Multi Input Multi Input Multi Input Pin 12 Buzzer Out Buzzer Out Buzzer Out Buzzer Out Multifunction inputs include the foll
33. ure that they are as small as possible and not placed in the same vertical position Also try to avoid using both black and white and grayscale images in the same vertical position Contrast and backlight controls can be used in some cases to help counteract crosstalk ghosting If there are bright lines in dark area the contrast is set too low Adjust backlight intensity to enhance visibility Due to the display nature of the TFT LCD screen the optimal viewing angle for the DP2XX series graphical display is at a maximum radius of 45 from either side of the screen Optimal viewing angle 45 P200 133 Display faulty application recovery The boot loader is always executed when the unit is powered The boot loader checks if the application has the completely downloaded flag set and in that case starts to execute it after a delay of 200 ms The delay gives an opportunity for the PLUS 1 Guide Service Tool to prevent the call to the application This allows a non functional application to be replaced by the boot loader This recovery function is activated by the Communication gt Recover ECU menu in the PLUS 1 Guide Service Tool USB communication requires more time than 200 ms to be established The units with USB have a function to force a recovery mode entry when the USB channel is used To force a recovery follow this