Home
        RC-200 Owner`s Manual
         Contents
1.  the Remote  Control is turned ON  all the circuitry inside the inverter becomes fully alive and  the AC output is made available  In this condition  even when no load is being  supplied  or  if a load is connected but has been switched OFF   the inverter  draws a small amount of current from the batteries to keep the circuitry alive  and is ready to deliver the required power on demand  This is called the    idle  current    or the    no load current draw     When the inverter is turned OFF using  this Remote Control  some control circuitry is still alive in the inverter and will  require very small current draw  Hence  when the load is not required to be  operated  turn OFF the ON OFF Switch on the inverter to prevent unnecessary  current drain from the battery     SECTION 6   SPECIFICATIONS                            MODEL NUMBERS OF PST 1500 12  PST 1500 24   COMPATIBLE INVERTERS PST 2000 12  PST 2000 24   CABLE SET Over connections  Length   5 metres 16 5  OPERATING TEMPERATURE RANGE 0 to 40  C  32  F to 104  F   DIMENSIONS  L X W X D  110 x 65 x 24 7 mm   4 33 x 2 56 x 0 97 in  Weight  Without cable   with cable  85 gm  256 gm  0 04 Ib   0 12 Ib       NOTE  Specifications are subject to change without notice    6   SAMLEX AMERICA INC     SECTION 7   WARRANTY    2 YEAR LIMITED WARRANTY    RC 200 Remote Control manufactured by Samlex America  Inc   the     Warrantor   is warranted to be free from defects in workmanship and  materials under normal use and service  The warr
2. CD   Light 3  9 LCD   Data 2  10 LCD   Ground 1   1  As shown in Figure 2   2  Mirror image of Remote Control Jack due to crossed over  rolled over connection of conductors     SAMLEX AMERICA INC    5    SECTION 4   INSTALLATION  Please refer to Fig  1  The Remote Control can be flush mounted on a wall or a  panel by making a suitable cut out to accommodate the projection in the back     Connect one end of the cable set to the RJ 50 Modular Jack  7  at the back and  the Remote and the other end to the RJ 50 Modular Jack on the inverter  Ensure  that the connection is firm and the tab on the plug securely locks in the jack     SECTION 5   OPERATION    Please refer to Fig 1  Please also refer to the Owner s Manual of the inverter  for associated details  NOTE  For the Remote Control to operate  the ON OFF Switch  on the inverter is required to be in ON condition to activate the control circuitry for the  Remote Control  Switch on the inverter first with the help of the Power ON OFF Switch on  the inverter  The output of the inverter can now be switched OFF ON by pressing the ON   OFF Push Button  1     See under headings    LCD Display    and    LED Display    above for information  on the operating conditions  Read the Owner s Manual of the inverter for  troubleshooting of abnormal conditions indicated by the LEDs     No Load Current Draw   As stated above  the ON OFF Switch on the inverter is required to be in ON  condition for the Remote to operate  When the ON OFF switch on
3. anty period is 2 years for the  United States and Canada  and is in effect from the date of purchase by the  user  the    Purchaser         Warranty outside of the United States and Canada is limited to 6 months  For a  warranty claim  the Purchaser should contact the place of purchase to obtain a  Return Authorization Number     The defective part or unit should be returned at the Purchaser s expense to the  authorized location  A written statement describing the nature of the defect   the date of purchase  the place of purchase  and the Purchaser s name  address  and telephone number should also be included     If upon the Warrantor   s examination  the defect proves to be the result of  defective material or workmanship  the equipment will be repaired or replaced  at the Warrantor    s option without charge  and returned to the Purchaser at  the Warrantor   s expense   Contiguous US and Canada only     No refund of the purchase price will be granted to the Purchaser  unless the  Warrantor is unable to remedy the defect after having a reasonable number  of opportunities to do so  Warranty service shall be performed only by the  Warrantor  Any attempt to remedy the defect by anyone other than the  Warrantor shall render this warranty void  There shall be no warranty for  defects or damages caused by faulty installation or hook up  abuse or misuse  of the equipment including exposure to excessive heat  salt or fresh water  spray  or water immersion     No other express warran
4. ghted when the inverter is in ON  condition  When the inverter is in OFF condition  this LED will not be lighted  This  LED shows that DC input is available to the inverter and that the input section of the  inverter is operating normally     Red LED  4  marked OVER LOAD  When lighted  it indicates that the AC output of the  inverter has been shut down due to over load     Red LED  5  marked OVER TEMP  When lighted  it indicates that the AC output of the  inverter has been shut down due to over temperature    Pinout of RJ 50 Modular Jack  The pinout of the RJ 50 Modular Jack  7  at the back of the unit is given at Fig     2 below   kcn      Toggle   Avec     Ground for LEDs  Vee   LED   Power ON     LED   Over Temp     LED   Over Load     LCD  Light  LCD   Data   LCD   Ground    12345678910    Soenavawne    Fig  2 Remote Control RC 200   Pinout of Modular Jack RJ 50    The standard numbering system of the pins of a Modular Jack  when looking into  the Jack  is from left to right  As the conductors of the cable are cross connected   rolled over   the pinouts at the Modular Jack in the inverter will be a mirror image  of the pinout of the Modular Jack in the Remote Control as shown in table below                                                     Pinout of Modular Jack on Pinout of Modular  the Remote Control    Signal Jack on the inverter    1 Toggle 10  2 Avcc 9  3 Ground for LEDs 8  4 Vcc 7  5 LED      POWER ON    6  6 LED      OVER TEMP    5  7 LED      OVER LOAD    4  8 L
5. output current in A           Active AC output power in Watts  W        Apparent Output AC Power in Volt    SAMLEX AMERICA INC    3    Amps  VA  and    Power Factor  PF    will not be displayed  will be displayed as    0       This is necessary because at power output  lt  2 5W  the noise on the output side  may be comparable to the low value of the load and the logic may not be able   to differentiate noise from load and hence  may display wrong values for these  parameters    Power Saving   Sleep Mode in the LCD Display   To save power  the LCD display will remain ON for 3 minutes from the time the  Display Push Button  2  is pressed and will then switch OFF into Sleep Mode  To  wake up  press the Display Push Button  2       amp     samlexpower         o  o DISPLAY 9        A  gt  Hz    gt  W gt  VA PF      EE   o e 8         ety gi EA   a    mooeLrc20  5   6        110         Pure  Sine Wave                E aan       Front View    Overall Depth  25 5            n    R2                            98                i  80  gt   i    Back View       LEGEND     Power ON OFF Push Button   TEF   Push Button to Change Display Screen  NOTE  All dimensions in mm     LCD Screen   LED     Overload   LED     Over Temp        LED     Power        RJ 50 Modular Jack    NOW awn             Fig  1 Remote Control RC 200   Layout and Dimensional Drawing    4   SAMLEX AMERICA INC     LED Display   The following LED displays are available      Green LED  6  marked POWER  This LED will be li
6. samlexpower    Remote Owner s   Please read this   manual BEFORE  Control for Manual operating your  Inverter RC 200 Remote    Control    RC 200    OWNER S MANUAL      SECTION 1   Safety denem A dnetee tenn 3  SECTION 2   Descipion T persans e te aster stee ete eect eee 3  SECTION 3   Layout of Controls  Indications    amp  Dimensional Drawings              cecccccseceseseeeeseseeeeseseesestecescaeeeetaeeeees 3  SECTION 4   Installation  copse erir a 6  SECTION 5        o  1 614  0     RNC ceererrerre meer seerr N ere peeret ere 6  SECTION 6   SOeCIICAHONS 25 2 058  2c  tedden ki eles 6  SECTION 7   Warranty  ccizniscaijecs tetova pests ante E E EE i EE 7    DETAILED PRODUCT INFORMATION   For a complete user manual including specifications  application notes   installation instructions  trouble shooting and more  please visit the  web page for this product on samlexamerica com  Product page can  be found using the    search by model    field     2   SAMLEX AMERICA INC     SECTION 1  SAFETY    Before using this Remote Control  please follow the Safety Instructions given in  the Owner s Manual for the inverter     SECTION 2   DESCRIPTION  RC 200 is a wired Remote Control that is compatible with the following series  of Inverters  PST 1500 12  PST 1500 24  and PST 2000 12  PST 2000 24     It is used to switch ON and switch OFF the inverter from a remote location  It  also displays the operational status using LCD display and colored LEDs  It is  provided with 5 Metres   16 5 Fee
7. t of connecting cable set with RJ 50 Modular  Plugs  10P10C   The conductors of the cable set have crossed over  rolled over   connections on the two RJ 50 plugs     SECTION 3   LAYOUT OF CONTROLS  INDICATIONS    amp  DIMENSIONAL DRAWING  Fig  1  page 4  shows the layout of controls and indications and dimensional  drawing     ON OFF Control  ON OFF Push Button  1  is used to switch ON and switch OFF the inverter  Every  time the ON OFF Push Button is pressed  a beep will be heard     LCD Display  LCD screen  3  is used to display the following 6 output parameters in a se   quential loop as given below     The screen changes to show the successive parameter in a sequential  manner every time the    Display Push Button     2  is pressed  Sequence is   Screen1 2 3 4 5 6 1 2 3       1  AC output voltage in Volts  V   2  AC output current in Amps  A   3  AC output frequency in Hertz  Hz   4 Active AC output power in Watts  W   The display is limited to a   range of 2 5W   3500W   5  Apparent Output Power in Volt Amps  VA   6  Power Factor  PF  When the inverter is switched ON using the ON OFF Push Button  1   the LCD    screen displays information as follows       It takes 2 to 6 sec for booting   initialization  During this time  all the above  6 parameters will be displayed as    0        If the load is  gt  2 5W  all the above 6 parameters will be available for display after  end of booting   initialization period     If the AC output power is less than 2 5W  parameters    AC 
8. ty is hereby given and there are no warranties which  extend beyond those described herein  This warranty is expressly in lieu of   any other expressed or implied warranties  including any implied warranty of  merchantability  fitness for the ordinary purposes for which such goods are  used  or fitness for a particular purpose  or any other obligations on the part of  the Warrantor or its employees and representatives     There shall be no responsibility or liability whatsoever on the part of the  Warrantor or its employees and representatives for injury to any persons  or  damage to person or persons  or damage to property  or loss of income or  profit  or any other consequential or resulting damage which may be claimed  to have been incurred through the use or sale of the equipment  including  any possible failure of malfunction of the equipment  or part thereof  The  Warrantor assumes no liability for incidental or consequential damages of any  kind     Samlex America Inc   the    Warrantor      www samlexamerica com SAMLEX AMERICA INC    7    Contact  Information  Toll Free Numbers    Ph  800 561 5885  Fax  888 814 5210    Local Numbers  Ph  604 525 3836  Fax  604 525 5221    Website  www samlexamerica com    USA Shipping Warehouse  Kent WA    Canadian Shipping Warehouse  Delta BC    Email purchase orders to  orders samlexamerica com    A    samlexamerica       
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  三菱電機株式会社 中津川製作所  L80 Tape Library Manuale dell`utente  〈取扱説明書〉 A B C - 株式会社リッチェル ペット用品  [ 富士ドライケム プラズマフィルター PF ] ≫PDF  Siig eSATA II ExpressCard RAID  Tahiti X - AVSIM Online  User manual  Sony DCR-TRV730 Camcorder User Manual  VM0808    Copyright © All rights reserved. 
   Failed to retrieve file