ART-L3 CURING LIGHT Pro Fiber Type User Manual
Contents
1. 10 20 second can be selected LED indicates the selected curing time Select curing mode by pressing the key M There are 3 modes Fast mode Pulse mode and Ramp mode can be choose Mode LED indicator indicates which curing mode was selected Adjust the optic fiber direction to suit different restoration position in mouth The optic fiber can be rotated by 360 Start curing Press the key S to activate the LED output Curing will be ended automatically or press key S again to end Press the key S to terminate the sleeping mode System Maintenance 1 Prevention of cross infection cleaning disinfection and storage It is mandatory that doctors need to wear sterilized gloves during these procedures at all time to avoid any possibilities of incomplete sterilization and or getting infected After use remove the optic fiber and eye protecting cap Clean and disinfect body with commercial alcohol based surface disinfecting solution Diirr FD 322 Henkel Incidin Liquid S amp M Mikrozid Liquid B Braun Meliseptol rapid Keep other solvents or flammable liquids as well as intense sources of heat away from the unit as they may damage its plastic housing Always safeguard charger Body against moisture as this may cause electrical short circuit or dangerous malfunction After each usage there will be saliva or other debris left on the light guide fiber and eye protecting cap it is necessary to clean the light guide fib
2. express written permission of BONART Co Ltd Product specifications as well as information presented in this manual are subject to change without prior notice PROPERTY OF BONART CO LTD ALL RIGHTS RESERVED ART is a registered trademark of BONART Co Ltd amp its affiliates Document No L3F1001 Rev 1 0 12 08 Printed in Taiwan R O C Operator Safety Please read carefully and completely before operating unit ENGLISH VERSION ART L3 LED CURING LIGHT Pro Only properly trained personnel are designated to use this system as described in this manual Only qualified personnel shall carry out any kinds of adjustment maintenance and repair of the equipment WARNING WARNING The intended use of ART L3 is for light curing only it is not suitable for work in full power more then 2 minutes continuously WARNING For continuous operation please wait for at least 30 seconds between each curing cycle WARNING Use only specified accessories Table of Contents NOTICE Copyright Operator Safety Contents Installation and Operations System Maintenance Specifications y A 11 Installation and Operations a oe Plug the optic fiber into the nozzle of the handpiece Attach the adaptor into the wall plug Attach the eye protecting cap to the tip of the optic fiber or put on blue light resistant goggles as a protection of user s eyes Adjust the curing time by pressing the key T Two timing
3. ART L3 CURING LIGHT Pro Fiber Type User Manual apal BONART CO LTD ECREP Jorgen Kruuse A S Marslev Byvej 35 DK 5290 Marslev Tel 909 594 8066 Denmark Fax 909 594 7266 Website http www bonartmed com Email sales bonartmed com COPYRIGHT 2008 12 BONART CO LTD NOTICE Please keep the contact points clean to avoid bad connection Power saving amp charging The ART L3 LED cordless Curing Light System is designed to automatically turn to sleep mode after the unit has been idle for a few minutes to be energy efficient J Insert the handpiece into the charging unit after use f l A N Do not operate Do not operate 20 second curing cycle for more than 3 times continuously to avoid LED from overheating AN Keep clean Check amp clean LED area after each use NOTE As an alternative option for user to use the system while in low battery Is to plug the power cord adapter to the system BONART Co Ltd owns all rights to this publication This publication should be used solely for the purpose of reference operation maintenance and repair of BONART equipment Not any part of this document may be reproduced or disseminated in any forms or any means for any other purpose In the event of inadvertent or deliberate publication BONART intends to enforce its rights to this manual under the copyright law No one may copy the materials presented in this manual without the
4. er and eye protecting cap with a supersonic cleaner first This can be done manually by scrubbing with a brush or by use of an ultrasonic cleaner with a solution of detergent and water After scrubbing The optic fiber and eye protecting cap should be rinsed thoroughly with water to remove all detergent and dried the rinsed light guide fiber and eye protecting cap and finally put the light guide fiber and eye protecting cap in a bag and then put it into a medical equipment autoclave and sterilize the fiber at 260 F 127 O for 30 minutes or as recommended by the manufacturer of the particular sterilizer used 2 Light output control Make sure that the optic fiber is clean and scratch free otherwise light output will be reduced and may be insufficient for proper curing of the material Control of light efficiency is recommended e g by using CureRite light intensity testing device The light intensity measured by CureRite testing device should exceed 1000 mW cm 3 Battery maintenance The battery needs approximately 2 hours to be fully recharged While the battery is recharging the indicator light will flash If fully charged the battery has a capacity of approximately 180 ten second cures approximately 30 minutes operating time Under most conditions of use the device only needs to be recharged 1 5 hours When battery is low the indicator light will come on and flash There should be approximately 80 ten second cures left in the reser
5. ved circuit to complete of the light curing treatment Light output is not reduced during this period After these 80 ten second cures the device will automatically switched off Caution To gain better performance of the battery the new battery must be fully charged for 2 5 hours 4 Charging method A 1 Plug in charging Stand 2 Insert the Handpiece into the charging stand refer Fig 3 B Plug in Handpiece refer Fig 2 9 Components 1 Light guide 2 Handpiece 3 Eyes protection cap 4 Power supply 5 Charger Specifications Power LED Curing Light Optical specifications wavelength 450 470nm Flux intensity 1000mW cm Min LED power consumption 3watt Equipment class Class II 0 Protection from electric shock Type BF a Operation environment Temperature 0 C 40 C Relative Humidity 10 90 non condensing Transport and storage conditions Temperature 0 C 60 C Relative Humidity 10 90 non condensing Atmospheric pressure 860 1060 hPa Power Adaptor Input 100 240VAC 50 60Hz 0 6A Output 5 0VDC 1 0A SW Max Battery Type Li ion Voltage DC 3 6V Capacity 700mAh Handpiece will operate approximately 30 minutes time starting upon complete recharging Time for battery recharge approximately 2 hours Autoclavable optic fiber light guide 8mm 1