Home

Axos Series

image

Contents

1. Oty 1 Mains Cable Oty 1 User Manual Oty 1 Certificate of Calibration OPTIONS AND ACCESSORIES FP EFT 32M FP EFT 100M2 IPAA FP SURGE 32A 3 Phase CDN EFT Burst 32 A 690 V 3 Phase CDN EFT Burst 100 A 690 V Capacitive Coupling Clamp for EFT Burst Automatic 3 Phase CDN Surge 32 A 690 V FP SURGE 100M2 3 Phase CDN Surge 32A 690 V TW 8 Telecom Wave Modul 10 700us PCD 121 Symmetrical Data amp Control Line Coupler PCD 126A Asymmetrical Data amp Control Line Coupler DEC 5 Symmetrical Data amp Control Line Decoupler DEC 6 Symmetrical Data amp Control Line Decoupler DEC 7 Asymmetrical Data amp Control Line Decoupler DIP 116 Automatic Dips Transformer 16 A 40 70 8096 MSURGE A Magnetic Field Test IEC EN 61000 4 9 VTM 15000 Isolation Test 1 2 50 us up to 10 kV VTM 15000 05 Isolation Test 1 2 50 us up to 10 kV 0 5J PDP 8000 HV Differential Probe 1000 1 for Surge CP 101 Current Probe Model for Surge ES External Emergency Stop Switch P12 WL External Warning Lamp P12 only with AXOS Telecom Wave Test System 2490850 2490800 2490810 2490830 2490840 2490820 2490850 2490170 2495860 2491300 2490700 2490180 4700915 2498010 2498030 2490141 2490151 2490161 2490410 2490441 2499960 2499692 2499911 2499931 4700751 4700750 UP Expandable Test Systems S 19 rA MIN Rm NEU L1 D Lm 7 7 L5 OPTIONS AND ACCESSORIES Surge Key Code Key Code for Surge extension AXOS 4700911 EFT Bur
2. ELTE RR ES OVERVIEW FEATURES amp BENEFITS Easy to operate with manual and automated test modes software as sisted test preparation pre defined test routines and visual aided test setups Economic amp Efficient Touch screen guarantees reduction of time and effort Experience and know how at a reasonable price Safe and reliable operation by using safety interlock warning lamp and emergency stop functions Voltage and current monitoring of surge impulses and EUT power provides valuable feedback to the test engineer Automatic generation of test report including test parameters test setup and test result APPLICATIONS Compliance amp pre compliance testing of electrical products CE marking Product development and debugging Compliance testing of telecom and wireless devices Overtesting in combination with external Telecom Wave Modul TW8 additional antenna coil MSURGE A required external voltage dips transformer DIP 116 required STANDARDS B EC EN 61000 4 4 EFT Burst W IEC EN 61000 4 5 Surge Edition 2 amp 3 1 2 50us 8 20us m IEC EN 61000 4 5 Surge 10 700us m IEC EN 61000 4 9 Magnetic Field m IEC EN 61000 4 11 AC Dips and Interrupts B IEC EN 61000 4 12 Ring Wave m IEC EN 61000 4 29 DC Dips and Interrupts m IEC EN 61000 6 1 Generic Residential m IEC EN 61000 6 2 Generic Industrial B IEC EN 60335 1 Household m IEC EN 60601 1 Medical B EC EN 60950 m EN 5
3. EN 61000 4 11 AXOS EFT BurstTest System Article no 2490830 Surge 1 2 50ys 8 20us IEC EN 61000 4 5 Telecom Wave 10 700us IEC EN 61000 4 5 amp ITU Ring Wave IEEE C62 41 Voltage Dips IEC EN 61000 4 11 Magnetic Field IEC EN 61000 4 9 Expandable Test Systems Z REAPER NAE a ho y suuba MEE x05 a Axos i g Ring Wave Test System u Telecom Wave System c a g j Article no 2490820 n a oa Article no 2490850 a2 THT 1 Surgei2 50gs 8 20 T i Surge 1 2 50ys 8 20us Lu IEC EN 61000 4 5 LU IEC EN 61000 4 5 Telecom Wave 10 700us IEC EN 61000 4 5 amp ITU Ring Wave IEEE C62 41 EFT Burst EFT Burst IEC EN 61000 4 4 IEC EN 61000 4 4 Voltage Dips Voltage Dips IEC EN 61000 4 11 IEC EN 61000 4 11 Magnetic Field Magnetic Field IEC EN 61000 4 9 IEC EN 61000 4 9 Activated by default Optionally available by activation via key code in combination with external Telecom Wave Modul TW8 external voltage dips transformer DIP 116 required agditional antenna coil MSURGE A required 18 AXOS SERIES UE wx mS uu ee mum SCOPE OF SUPPLY OPTIONS amp ACCESSORIES SCOPE OF SUPPLY AXOS Compact Immunity Test System AXOS Surge Test System AKOS EFT Burst Test System AXOS Voltage Dips Test System AXOS Ring Wave Test System AXOS Telecom Wave Test System Oty 1 Immunity Test System AXOS Oty 1 Telecom Wave Modul TS 8 10 700us
4. above the requirements of the standards Together with the ability of changing test parameters during test AXOS is not only the ideal product for compliance and pre compliance testing it is useful for monitoring amp debugging function during design phase as well A wide range of cost efficient and user friendly coupling decoupling networks for power lines as well as for symmetrical and asymmetrical data and signal lines are available as options T E eam E AXOS front view AXOS rear view Expandable Test Systems Z 3 MERERI PPAR RR a Seem OVERVIEW FEATURES amp BENEFITS Easy to operate with manual and auto mated test modes software assisted test preparation pre defined test rou tines and visual aided test setups Economic amp Efficient Touch screen guarantees reduction of time and effort Experience and know how at a reasonable price Safe and reliable operation by using safety interlock warning lamp and emergency stop functions Voltage and current monitoring of surge impulses and EUT power pro vides valuable feedback to the test engineer Automatic generation of test report including test parameters test setup and test result APPLICATIONS Compliance amp pre compliance testing of electrical products CE marking Product development and debugging Compliance testing of telecom and wireless devices STANDARDS m EC EN 61000 4 4 EFT Burst B IEC EN 61000 4 5 Surge Ed
5. ns 15 4100 ns at 1 000 Ohm Burst mode normal continuous Integrated single 264V AC 16A real random phase coupling 220V DC 10A decoupling network Expandable Test Systems AZ BARRE 2 REA II m A E7700 00 CEU ho y UNI ri IEC EN 61000 4 5 EDITION 2 amp UPCOMING EDITION 3 SURGE COMBINATION WAVE Output voltage 0 2 5 0 kV 10 Output current 0 1 2 5 kA 10 Voltage rise time 1 2 us 30 Current rise time 8 us 20 Voltage duration 50 us 20 Current duration 20 us 20 Polarity postive negative Integrated single 264 V AC 16A alternate phase CDN 220V DC 10A Output impedance 2 Ohm Phase sync 0 359 with 1 steps or Impulse trigger automatic 2 s 100 min asynchronous mode manual Counter preselect 1 1 000 infinite external trigger input Counter 100 000 Peak voltage BNC output 1000 1 Peak current BNC output 1 kA V monitor display 3 digits monitor display 3 digits IEC EN 61000 4 11 EDITION 2 AND IEC EN 61000 4 29 DIPS amp INTERRUPTS Max voltage 264 V AC DC Interrupt time 0 5 period 800 peri ods 100 us 1000 minutes Max current 16A AC DC continuous Interval time 1 period 800 periods 20A for bs synch 23Afor3s 100 us 1000 minutes 40Afor3s asynch gt 500A inrush current Trigger automatic Test time 1 s 1000 minutes manual infinite external trigger input Interrupt 096 Phase sync 0 359 16 40 50 dip level 0 99 with external 60 Hz voltage source asynchronous
6. 5000 05 PDP 8000 CP 101 ES WL Calibration Surge Key Code EFT Burst Key Code Dips Key Code 3 Phase CDN EFT Burst 32 A 690 V 3 Phase CDN EFT Burst 100A 690 V Capacitive Coupling Clamp for EFT Burst Automatic 3 Phase CDN Surge 32A 690 V 3 Phase CDN Surge 32A 690 V Symmetrical Data amp Control Line Coupler Asymmetrical Data amp Control Line Coupler Symmetrical Data amp Control Line Decoupler Symmetrical Data amp Control Line Decoupler Asymmetrical Data amp Control Line Decoupler Automatic Dips Transformer 16 A 40 70 8096 Magnetic Field Test IEC EN 61000 4 9 Isolation Test 1 2 50 us up to 10 kV Isolation Test 1 2 50 us up to 10 kV 0 5J HV Differential Probe 1000 1 for Surge Current Probe Model for Surge External Emergency Stop Switch P12 External Warning Lamp P12 Accredited Calibration AKOS Key Code for Surge extension AKOS Key Code for EFT Burst extension AKOS Key Code for Voltage Dips extension AKOS 2490170 2495860 2491300 2490700 2490180 2498010 2498030 2490141 2490151 2490161 2490410 2490441 2499960 2499692 2499911 2499931 4700751 4700750 2490420 4700814 4700815 4700816 12 AXOS SERIES E m ee um orm AX0S EXPANDABLE TEST SYSTEM extus 2 The new AKOS expandable test system integrates all of the best features of several stand alone test systems into one single economic solution It can be individually combined either with 7 kV Sur
7. 5024 m IEEE C62 41 B ITU K 20 K 21 K 44 K 45 14 AXOS SERIES TECHNICAL DATA AXOS GENERAL DATA Control power 85V 264V Dimensions 22 6U 50 60 Hz W x H x D 45 x 27 x 50 cm User test storage unlimited Weight 30 kg Remote interface Ethernet RJ45 USB for USB memory stick Display 7 800x480 24 bit AUX interface D sub 37p for external with touch screen CDN external trans former etc External trigger 5DVTTL Synch input BNC 10 V 264 V AC input L Trigger output 5VITL External start stop 5VTTL starts stops input predefined test se quence EUT failed input 5VTTL Analog output 0 10V for use with external options Warning lamp 2x24V 1ADC Safety circuit stops the test when output unlocked IEC EN 61000 4 4 EDITION 2 amp 3 EFT BURST Output voltage 0 2 5 0 kV 10 at Spike frequency 1Hz 1MHz coaxial output Polarity pos neg alternate Burst duration 10us 1s Output impedance 50 Ohms Burst period 1ms 10s Rise time 5 ns x3096 Test time 1 s 1000 minutes Impulse duration 50 ns 30 at 50 Trigger automatic manual Ohm external trigger input 50 ns 15 100 ns at 1000 Ohm Burst mode normal continuous Integrated single 264V AC 16A real random phase coupling 220V DC 10A decoupling network IEC EN 61000 4 5 EDITION 2 amp UPCOMING EDITION 3 SURGE COMBINATION WAVE Output voltage 0 2 70 kV 10 Output current 0 1 3 5 kA 10 Voltage rise time 1 2 us 30 Current rise time 8
8. HAEPELY GM SERIES ANUS EXPANDABLE TEST SYSTEMS RING WAVE TELECOM WAVE SERVICES EFT BURST l VOLTAGE DIPS MAGNETIC FIELD extus P 4 ae O F aus Je e mmc o A Pr e i e EX am EE H 4 A 0666 ee m 7 vago axas gog A oS in kh EE l cego amp a p a NI www haefely com 9 Haefely is a subsidiary High Voltage C Test Business precision of Hubbell Incorporated swiss made abad HAEFELY EE 2 AXOS SERIES EMC IS ALL ABOUT STANDARDS HAEFELY COVERS THEM IN JUST ONE SINGLE BOX The standards are you really familiar with all of them Whether people talk about generic standards or product specific standards stipulated by law or demanded from the manufacturer HAEFELY has integrated all of them Take benefit from the most modern and easy to use conducted immunity test system ever built Welcome to the AXOS series Indoor applicances Domestic White goods Brown goods Household Lightning devices Portable tools Home automation Outdoor applicances Renewable energy Solar panels Windmills Turbines Inverters Infrastructure Industrial Robotics Welding machines Packing machines Production lines Laboratory equipment Telecom Outdoor lines Repeater Switching stations Data concentrators Telecommunication centers Medical Monitoring Scanning Analysing Pumps Implan
9. al operation IEC EN 61000 4 11 Voltage Dips and Interrupts Voltage failures occur following switching operations short circuits response of fuses and when running up heavy loads The quality of the electrical power supply is increasingly becoming a central topic of discussion The interference sources in the mains caused by electronic power control with non linear components e g thyristors are used more frequently in domestic appliances such as hotplates heating units washing machines television sets economy lamps PCs and industrial systems with speed controlled drives IEC EN 61000 4 9 Pulsed Magnetic Field Under normal operating conditions an AC current generates a steady magnetic field so that equipment such as monitors close to AC power lines could suffer interference Under fault conditions a sudden high current level can result in a short duration ma gnetic field Lightning strokes or short circuit fault currents in the power network can generate high level short duration magnetic fields 4 AXOS SERIES RING WAVE TELECOM WAVE m 78H EERE THE STANDARDS IEC EN 61000 4 12 Ring Wave IEEE C62 41 Ring waves are used to simulate lightning or switching effects in domestic single or three phase supplies within an adequately protected building The waveform has similar characteristics in both open and short circuit conditions The ring wave is characterised as a bipolar damped oscillat
10. ge Combination Wave 7 kV Ring Wave 7 kV Telecom Wave 5 kV EFT Burst or Dips amp Interrupts along with an integrated single phase coupling decoupling network This allows quick and completely automated testing to the most common IEC EN ANSI ITU IEEE and UL standards The AXOS can either be operated via front panel by large colour graphic interface or remotely from the PC The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable even for less frequently users Numerous additional functions such as external start stop function allows easy integration of the test system also in customer specific test environments All the test parameters can be varied in a broad range wide above the requirements of the standards Together with the ability of changing test parameters during test AXOS is not only the ideal product for compliance and pre compliance testing it is useful for monitoring amp debugging function during design phase as well A wide range of cost efficient and user friendly coupling decoupling networks for power lines as well as for symmetrical and asymmetrical data and signal lines are available as options s m g BENE A wu 5 4 ti eara lt 2892 s YA e A G m wai _ ba AXOS front view AXOS rear view external Telecom Wave Modul TW8 required Expandable Test Systems Z 8 ILL 00 Lt
11. ing wave IEC EN 61000 4 5 Telecom Wave 10 700ys ITU K 20 K 21 K 44 K 45 Telecommunication networks and lines are often disposed to lightning strikes and their associated effects All telecommunication systems linked with lines in Expandable Test Systems S 5 DA AR RR mW WEEIL E Zee THE MODULAR CONCEPT Welcome to the unique design and concept of modularity designed by HAEFELY HAEFELY is recognizing an increasing interest in testing departments to configure the required functions in compact immunity test systems more flexible than ever For that reason HAEFELY designed a unique concept of modularity which eviscerates large additional investments for customers in the future Moreover constantly reduced product development times call for powerful easy to operate and ready to use conducted immunity test systems which can be expanded in a multitude of different test applications Customer requirements particularly in the telecommunications and industrial electronics sector emphasize a test system s ac curacy and modularity thus clearly pointing to easy to expand T amp M equipment that is favourably priced and suitable for most of industries The new AXOS series has been tailored to exactly meet these requirements offering special cost advantages forT amp M applications in the development production and servicing of telecommunications components as well as safety and industrial electro nics All AXOS test systems c
12. ition 2 amp 3 m JEC EN 61000 4 9 Imp Magnetic Field B IEC EN 61000 4 11 AC Dips and Interrupts B IEC EN 61000 4 29 DC Dips and Interrupts m JEC EN 61000 6 1 Generic Residential m IEC EN 61000 6 2 Generic Industrial B IEC EN 60335 1 Household B IEC EN 60601 1 Medical E and many more INDUSTRIES B Industrial B Residential E Components B Medical m Renewable energy B Telecom Bc co wm m ma Tm T AXOS SERIES TECHNICAL DATA AXOS GENERAL DATA Control power 85 V 264V Dimensions 19 4U 50 60 Hz WxHxD 45 x 18 x 49 cm User test storage unlimited Weight 25 kg Remote interface Ethernet RJ45 USB for USB memory stick Display 7 800x480 24 bit AUX interface D sub 37p for external with touch screen CDN external trans former etc External trigger 5DVTTL Synch input BNC 10 V 264 V AC input a Trigger output 5VTTL External start stop 5VTTL starts stops input predefined test se quence EUT failed input 5VTTL Analog output 0 10 V for use with external options Warning lamp 2x24V 1ADC Safety circuit stops the test when output unlocked IEC EN 61000 4 4 EDITION 2 amp 3 EFT BURST Output voltage 0 2 5 0 kV 10 Spike frequency 1 Hz 1 MHz at coaxial output Polarity pos neg alternate Burst duration 10 us 1s Output impedance 50 Ohm Burst period 1ms 10s Rise time 5 ns 30 Test time 1 s 1 000 minutes Impulse duration 50 ns 30 at Trigger automatic manual 50 Ohm external trigger input 50
13. mode RMS voltage BNC output 100 1 RMS current BNC output 10 A V monitor display 4 digits monitor display 4 digits 10 AXOS SERIES OVERVIEW OF AXOS SERIES AXOS CompactTest System Article no 2490400 AXOS EFT BurstTest System Article no 2490402 Surge 1 2 50ys 8 20us IEC EN 61000 4 5 Voltage Dips IEC EN 61000 4 11 Magnetic Field IEC EN 61000 4 9 4 Activated by default Optionally available by activation via key code external voltage dips transformer DIP 116 required additional antenna coil MSURGE A required E E m mum PER AXOS Surge Test System Article no 2490401 EFT Burst IEC EN 61000 4 4 Voltage Dips IEC EN 61000 4 11 AXOS Dips Test System Article no 2490403 Surge 1 2 50ys 8 20us IEC EN 61000 4 5 EFT Burst IEC EN 61000 4 4 Magnetic Field IEC EN 61000 4 9 Expandable Test Systems Z yy TEE PELLIT mcm NW WAA EE E a a SCOPE OF SUPPLY OPTIONS amp ACCESSORIES SCOPE OF SUPPLY AXOS Compact Immunity Test System 2490400 AXOS Surge Test System 2490401 AXOS EFT Burst Test System 2490402 AXOS Voltage Dips Test System 2490403 Oty 1 Immunity Test System AKOS Oty 1 Mains Cable Oty 1 User Manual Oty 1 Certificate of Calibration OPTIONS AND ACCESSORIES FP EFT 32M FP EFT 100M2 IPAA FP SURGE 32A FP SURGE 100M2 PCD 121 PCD 126A DEC 5 DEC 6 DEC 7 DIP 116 MSURGE A VTM 15000 VTM 1
14. ome equipped with all the hardware needed for instant upgrades by only entering optional key codes into the licence code manager of the unit After entering the key code s the additional test functionalities like Surge Combination Wave Ring Wave Telecom Wave EFT Burst or Voltage Dips and Interrupts become available immediately No direct intervention has to be done by the user at all License Manager of the AXOS series 6 AXOS SERIES TE wm mS E FH um o UP AXOS EXPANDABLE TEST SYSTEM gxus The new AXOS expandable test system integrates all of the best features of several stand alone test systems into one single economic solution It can be individually combined either with 5 kV Surge Combination Wave 5 kV EFT Burst Dips amp Interrupts along with an integrated single phase coupling decoupling network This allows quick and completely automated testing to the most common IEC EN ANSI IEEE and UL standards The AXOS can either be operated via front panel by large colour graphic interface or remotely from the PC The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable even for less fre quently users Numerous additional functions such as external start stop function allows easy integration of the test system also in customer specific test environments All the test parameters can be varied in a broad range wide
15. rush current Trigger automatic Test time 1 s 1000 minutes manual infinite external trigger input Interrupt 096 Phase sync 0 359 16 40 50 60 Hz dip level 096 9996 with external asynchronous mode voltage source RMS voltage BNC output 100 1 RMS current BNC output 10 A V monitor display 4 digits monitor display 4 digits IEC EN 61000 4 12 AND IEEE C62 41 Ring Wave Max voltage 0 2 7 0 kV 1096 Repetition rate Upto 30 pulses min Frequency 100 kHz Polarity Positive negative alternate Rise time OC 0 5 us Floating output Max 460V AC Rise time SC 1 us Phase sync 1 accuracy Impedance 12 Ohm 30 Ohm Damping rate 60 of previous peak 16 AXOS SERIES OVERVIEW OF AXOS SERIES AXOS CompactTest System Article no 2490800 a m ow ow Telecom Wave 10 700us IEC EN 61000 4 5 amp ITU AXOS Dips Test System Article no 2490840 3 Surge 1 2 50us 8 20us HE IEC EN 61000 4 5 Telecom Wave 10 700us IEC EN 61000 4 5 amp ITU Ring Wave IEEE C62 41 EFT Burst IEC EN 61000 4 4 Magnetic Field IEC EN 61000 4 9 in combination with external Telecom Wave Modul TW8 external voltage dips transformer DIP 116 required additional antenna coil MSURGE A required Urm a AXOS Surge Test System Article no 2490810 Telecom Wave 10 700us IEC EN 61000 4 5 amp ITU Ring Wave IEEE C62 41 EFT Burst IEC EN 61000 4 4 Voltage Dips IEC
16. st Key Code Key Code for EFT Burst extension AXOS 4700912 Ring Wave Key Code Key Code for Ring Wave extension AXOS 4700913 Dips Key Code Key Code for Voltage Dips extension AXOS 4700914 VALUE ADDED SERVICES B Pre amp After Sales Support SERVICES B Application Support E Commissioning BW Warranty Extension B Calibration accredited amp factory B Training and Seminars B Rental units l y ii nn M E ina i hk 1 Ul n m XT ii iui E T nm pm i n 1 i ili nn rung MI p T ya MU T MEI D Headquarters China Sales amp Service Office North American Office Haefely Test AG HAEFELY Representative Office Hipotronics Inc Birsstrasse 300 8 1 602 Fortune Street Haefely EMC Division 4052 Basel No 67 Chaoyang Road Chaoyang District 1650 Route 22 Switzerland Beijing China 100025 Brewster NY 10509 41 61 373 41 11 86 10 8578 8099 1 845 279 3644 x amp 41 61 373 49 12 amp 486 10 8578 9908 amp 1 845 279 2467 7 emcsales haefely com 7 sales haefely com cn i emcsales 9 hubbell haefely com 2 gt
17. ts Transportation Automotive Motorcycles Trucks Electric vehicles Charging stations IT Computers Printers Modems Hubs Phones Servers Defense Component testing Communications Vehicles Aircrafts Satellites Expandable Test Systems 1 RT REEL A SURGE EFT BURST VOLTAGE DIPS THE STANDARDS IEC EN 61000 4 5 Surge Combination Wave 1 2 50ys 8 20yus Surge events can be generated by lightning phenomena switching transients or the activation of protection devices in the power distribution system A surge itself is influenced by the propagation path taken so that impulses from the same event may have different forms depending upon where a measurement is taken Combination Wave Generators CWG simulate a surge event in power lines close to or within buildings Mostly the disturbances are tolerable because they are single events IEC EN 61000 4 4 Electric Fast Transients EFT Burst Industrial measurement and control equipment nearly always use conventional control units containing relays or other electro mechanical switching devices Fluorescent lamp ballast units insufficiently suppressed motors hair dryers vacuum cleaners drills etc are found everywhere in the public power supply All of these are primarily inductive loads which generate interference when switched on or off EFT events can cause microprocessor units to malfunction or reset with corresponding disruption to norm
18. us 20 Voltage duration 50 us 20 Current duration 20 us 20 Polarity pos neg alternate Integrated single 264V AC 16A Output impedance 2 Ohms phase CDN 220V DC 10A Phase sync 0 359 with 1 steps Impulse trigger automatic 2 s 100 min or asynchronous manual mode external trigger input Counter preselect 1 1000 infinite Counter 100000 Peak voltage BNC output 1000 1 Peak current BNC output 1 kA V monitor display 3 digits monitor display 3 digits Expandable Immunity Test Systems S 15 MAREA AE WALA II 323 mE NI i1 mE XAR Br IEC EN 61000 4 5 Telecom Wave ITU K 20 K 21 K 44 K 45 Max voltage 0 2 70 kV 10 Source 15 Ohm impedance 40 Ohm coupling 40 Ohm gas arresters Front time OC 10 us 30 Outputs 1 x 15 Ohm direct 4 x 40 Ohm direct 4 x 40 Ohm gas arresters Decay time OC 700 us x 2096 Impulse output Banana connector Undershoot OC 30 Impulse input HV connector Front time SC 5 us 20 Transitions V Polarity Decay time SC 320 us 20 Number of 1 10 000 events Undershoot SC lt 30 Repetition rate upto 30 min Polarity Positive negative Weight 10 kg alternate IEC EN 61000 4 11 EDITION 2 AND IEC EN 61000 4 29 DIPS amp INTERRUPTS Max voltage 264 V AC DC Interrupt time 0 5 period 800 periods 100 us 1000 minutes Max current 16A AC DC continuous Interval time 1 period 800 periods 20A for bs synch 23A for 3s 100 us 1000 minutes 40 A for 3s asynch gt 500 A in