Home

Orville - How to build a remote control unit

image

Contents

1. COL 0 40100Qb 0 Oscillator 440 3 COL 0 40a0001 401000b oscillator parms osc 5 NUM 0 40b0001 40a0001 freq 3 Lz freq 440 00001 0 20000 0 099991 SET 2 40d0001 4020001 waveform s waveform 0 sine 3 NUM 0 40c0001 4020001 duty cy le 3 1f duty 50 0 100 0 099991 NUM 0 40f0001 40a0001 J vel 3M Db level 20 96 000004 20 0 099991 NUM 0 4100001 40a006 1 offset 3 4f o offset 0 1 1 0 000092 COL 0 4030001 401000b sweep parameters sweep 4 NUM 0 4050001 4030001 rate 3 1f Hz swp rate 1 0 1000 0 099991 SET 2 4060001 4030001 waveform s swp wave 0 sine 8 NUM 4070001 4030001 duty cycle 3 1f BI swp duty 50 0 100 NUM 0 4080001 4030001 amount 3 1f swp amt 0 0 20000 0 099991 COL e 4020004 401000b info info 7 L INF 0 4020002 4020004 s text General purpose oscillator On loading H INF 0 4020066 4020004 s text it is set to a 440 Hz sine wave for H INF 0 40200ca 4020004 s text tuning Mono out Allows addition of an H INF 0 402012e 4020004 s text offset and modulation Output will clip H INF 0 4020192 4020004 s text above 12dB Aliasing will be audible H INF 0 40201f6 4020004 s text on triangular and square waves at 4 I
2. AMETERS_DUMP message which is the entire parameter tree for the requested value This can be large and take several seconds to send Intelligent use of the flags to send only such data as is needed will significantly speed up operation The representation for the userobject data is as described above with each object terminated by a CR LF Example SYSEXC_PARAMETERS_WANT 401000b 0 a parameter tree for the preset in DSP A might return the following data COL 0 401000b 401000b Oscillator 440 3 COL 0 40a0001 401000b oscillator parms osc 5 NUM 0 40b0001 40a0001 freq 3 1f Hz freq 440 00001 0 20000 0 099991 SET 2 40d0001 40a0001 waveform s waveform 0 sine 3 sine triangle square NUM 0 40c0001 40a0001 duty cycle 3 1f duty 50 0 100 0 099991 NUM 0 40f0001 40a0001 level 3 1f Db level 20 96 000004 20 0 099991 NUM 0 4100001 40a0001 offset 3 4f offset 0 1 1 0 000092 COL 0 4030001 401000b sweep parameters sweep 4 NUM 0 4050001 4030001 rate 3 1f Hz swp rate 1 0 1000 0 099991 SET 2 4060001 4030001 waveform s swp wave 0 sine 8 sine triangle square peak warp sin warp tri half sin half peak NUM 0 4070001 4030001 duty cycle 3 1f swp duty 50 0 100 0 099991 NUM 0 4080001 4030001 amount 3 1f swp amt 0 0 20000 0 099991 COL e 4020004 401000b info info 7 INF 0 4020002 4020004 s text General purpose oscillator On loading etc etc etc userobj lwp Page 7 of 9 njr Monda
3. How to build a remote control unit for the Eventide Orville This document describes the use of the MIDI Sysex protocols offered by the Eventide Orville which are suitable for a PC or Mac based remote control system Be aware that actual computer programming may be required to make use of them These protocols may also be offered on future Eventide audio products and are in general independent of software versions The text below refers often to Orville but should be taken to apply to any of the supported systems They are currently supported by the following Eventide Products Orville V2 705 or later DSP7000 7500 4000B all Eclipse V1 1 or later i The Orville operating system is made up of userobjects These may for example display a value give the function of a push button or act as a menu page Userobjects have the following features ii Each one is identified by a unique ID number known as the key ii They usually contain some data in various formats iv Each one contains a statement which is a C type format string to be used in displaying their data This may be empty v Each one contains a tag which can be used as a label for buttons This may be empty vi There are a number of different types of userobject See below for detailed information vii A userobject of a particular type also has a subtype This can usually be ignored viii Some userobjects are read only or constant these display inform
4. NF 0 402025a 4020004 s text higher frequencies userobj lwp Page 4 of 9 njr Monday October 01 2001 How to build a remote control unit for the Eventide Orville Orville may be accessed via its root object which has a key value of 0 This is a collection containing the roots of the tree for each main mode for example PROGRAM SETUP etc The contents of the tree may vary between different products and software versions but as long as it is reloaded each time it is accessed everything will stay in step Here is an example of the contents of the main root collection i COL 0 401000b 0 Oscillator 440 3 ii COL 0 8010007 0 Clrmtn s NemWhipper NWhip 6 ii COL 0 10010000 0 setup functions setup d iv 80 10040000 0 v COL 0 10020000 0 program functions program 9 vi COL 0 10030000 0 level functions level 4 vii COL 0 10030500 0 bypass functions bypass 4 The key to keys A key is a 32 bit unique ID value Its top 4 bits D28 31 are zero fora PARAMETER key The next 2 bits D26 27 tell you if a PARAMETER key is for DSP A 01 or DSP B 1 In Eclipse the modulator block is DSP C 11 i i1 are the PARAMETER trees for the A and B machines Note the double quotes in ii while the apparent double quotes in i are in fact a pair of single quotes as a place mark for the absent tag Gii is the SETUP tree iv is an undocumented type and should be ignored v is the tree for the PR
5. OGRAM functions vi gives access to the LEVEL functions vii is the BYPASS root The above ordering and contents should not be assumed but should be scanned every time communication is established between the remote control and the Orville For example a product where the BYPASS button acts directly DSP7000 rather than via a menu as on Orville might have a trigger rather than a collection at that point userobj lwp Page 5 of 9 njr Monday October 01 2001 How to build a remote control unit for the Eventide Orville MIDI Sysex message formats The format of the messages described in this section is as follows OxFO EVENTIDE H4000 lt id gt lt message_code gt lt message data gt OxF7 the OxFO and OxF7 are standard MIDI for system exclusive and end of system exclusive All other bytes have d7 set to 0 define EVENTIDE 0x1C define H4000 0x70 lt id gt is the device id number If this is zero all Orvilles will listen to the message lt message_code gt is a byte determining the message function For the purposes of this document its can be one of Message Response SYSEXC_PARAMETERS_WANT SYSEXC_PARAMETERS_DUMP SYSEXC_VALUE_PUT SYSEXC_VALUE_ DUMP SYSEXC_OBJECTINFO_WANT SYSEXC_OBJECTINFO_DUMP All the above messages have one or more ascii parameters with spaces between them They are described in detail below Their parameters may be one of the following lt key gt lt long gt
6. ation without allowing it to be changed for example the sample rate of an incoming signal some userobjects are write only these are triggers which act as push button switches ix Most userobjects contain a number of attributes which give further information necessary for their use Userobject Types i Collection COL A collection acts as a container for two or more userobjects Beyond this it has no data If the tag is blank it implies that this userobject is not intended to be displayed it will serve the function of ganging either multiple controls to bind them together or multiple menu pages to create a stacked menu See the Orville User Manual for explanation of these terms If the tag is non blank it means that the collection should be viewed as a menu page with its contained userobjects displayed upon the page In this instance the statement might be used as a title for the menu page Each object contained in the collection is known as a subobject A subobject refers to their container as their parent userobj lwp Page 1 of 9 njr Monday October 01 2001 How to build a remote control unit for the Eventide Orville ui iii iv v vi Attributes the number of subobjects in the collection Representation COL lt subtype gt lt key gt lt parent key gt lt statement gt lt tag gt lt number subobjects gt Number NUM A number userobject contains a floating point numeric val
7. key value hexadecimal assumed lt long gt ascii hexadecimal number with leading zeros suppressed lt float gt ascii floating point value with leading and non significant trailing zeros and decimal points suppressed Example 1 0 is sent as 1 lt string gt ascii text string If the first character is a single or double quote this is the start and end delimiter otherwise the delimiter is a space No string may contain all three of single quote double quote space Here is an example of the SYSEX message you would send to set the value of an object with a key value of 0x1000 to 3 4 P Tego mst 34 ASCID a A A FO EN 01 2D 31 30 30 30 n 2E 34 F7 H4000 ISYSEXC VALUE PUT SPACE userobj lwp Page 6 of 9 njr Monday October 01 2001 How to build a remote control unit for the Eventide Orville SYSEXC_PARAMETERS_ WANT lt key gt lt flags gt lt key gt is the key value for the object whose parameters are desired lt flags gt is a bitmapped value which optionally reduces the amount of information that is sent It may have the following values lt not present gt 0 no effect 1 make the returned value for the number of members for each COLLECTION zero i e do not return the members 2 make the returned value for the number of strings for each SET zero i e do not return the strings The response to this message is a SYSEXC_PAR
8. onday October 01 2001 How to build a remote control unit for the Eventide Orville SYSEXC_VALUE_PUT lt key gt lt value gt This message receives the key for a single object and returns a SYSEXC_VALUE_DUMP message If lt value gt is present it will be written to the userobject and should be of a suitable type for the object SET should be a lt long gt being the index for the desired string NUM should be a lt float gt STR should be a lt string gt TRG can be anything it is ignored the act of writing causes the trigger to occur COL CON INF can not be written to it will have no effect The returned SYSEXC_VALUE_ DUMP will be of the form lt key gt lt float gt for a NUM lt key gt lt long gt lt string gt for a SET lt value gt will be the current index lt key gt lt string gt for an INF lt key gt lt float gt for a CON lt key gt only for a TRG or a COL This message can be used to find the current value of an object without changing it simply by not sending a value userobj lwp Page 9 of 9 njr Monday October 01 2001
9. t contains a number of text strings one of which is selected at any given time Thus its data is the index of the selected string which can be read or written userobj lwp Page 2 of 9 njr Monday October 01 2001 How to build a remote control unit for the Eventide Orville Attributes number of strings value of each string value of selected string Representation SET lt subtype gt lt key gt lt parent key gt lt statement gt lt tag gt lt current index gt lt selected string gt lt number of strings gt lt string text gt userobj lwp Page 3 of 9 njr Monday October 01 2001 How to build a remote control unit for the Eventide Orville Userobject trees The userobjects in the Orville are arranged as a tree with collections acting as the branching points Consider for example the PARAMETER display of the preset below consisting of three menu pages each one of which is shown The drawing below shows the tree structure and the contributions made by data and attributes of the various userobjects to the Orville screens The entire user interface of the fa Oscil lator 440 ai Oscillator 440_ info A a offset 0 0000 General purpose oscillator On loading waveform sine waveform sine it is set to a 440 fiz sine wave for duty cycle 50 0 duty cycle 50 0 tuning Hono out Allows addition of an level 20 0 Db amount 0 0 x offset and modulation Output will clip ose a inte See A
10. ue The user can both read and write this value Attributes the maximum and minimum values and the resolution which is the amount the value should be increased or decreased for each click of a wheel or button Representation NUM lt subtype gt lt key gt lt parent key gt lt statement gt lt tag gt lt current value gt lt minimum gt lt maximum gt lt resolution gt String STR A string userobject contains a text value The user can both read and write this value Attributes none Representation STR lt subtype gt lt key gt lt parent key gt lt statement gt lt tag gt lt current value gt Constant CON A constant userobject contains a floating point numeric value The user can only read this value it cannot be changed directly Note that a constant value may change as a result of changes to other userobjects or as a result of changes in the system s state Attributes none Representation CON lt subtype gt lt key gt lt parent key gt lt statement gt lt tag gt lt current value gt Information INF An information userobject contains a text value The user can only read this value it cannot be changed directly An information value will not usually changes as a result of changes to other userobjects Attributes none Representation INF lt subtype gt lt key gt lt parent key gt lt statement gt lt tag gt lt current value gt Set SET A set userobjec
11. y October 01 2001 How to build a remote control unit for the Eventide Orville SYSEXC_OBJECTINFO_WANT lt key gt lt flags gt This message receives the key for a single object and returns a SYSEXC_OBJECTINFO_DUMP message It differs from SYSEXC_PARAMETERS_ WANT in that if the key is fora COLLECTION only the members of the COLLECTION will be sent members of nested COLLECTION will not be sent Examples SYSEXC_OBJECTINFO_WANT 0 COL 00 0 ORVILLE ROOT OBJECT ORVILLE 7 COL 0 401000b 0 Oscillator 440 0 COL 0 801000b 0 16mm Projector 0 COL 0 10010000 0 setup functions setup 0 8 0 10040000 0 unknown type ignore COL 0 10020000 0 program functions program 0 COL 0 10030000 0 level functions level 0 COL 0 10030500 0 bypass functions bypass 0 SYSEXC_OBJECTINFO_WANT 01 COL 00 0 ORVILLE ROOT OBJECT ORVILLE no members of collection SYSEXC_OBJECTINFO_WANT 40a0001 2 COL 0 40a0001 40a0001 oscillator parms osc 5 NUM 0 40b0001 40a0001 freq 3 1f Hz freq 440 00001 0 20000 0 099991 SET 2 40d0001 40a0001 waveform s waveform 0 sine amp no strings in set NUM 0 40c0001 40a0001 duty cycle 3 1f duty 50 0 100 0 099991 NUM 0 40f0001 40a0001 level 3 1f Db level 20 96 000004 20 0 099991 NUM 0 4100001 40a0001 offset 3 4f offset 0 1 1 0 000092 SYSEXC_OBJECTINFO_WANT 40d0001 SET 2 40d0001 40d0001 waveform s waveform 0 sine 3 sine triangle square userobj lwp Page 8 of 9 njr M

Download Pdf Manuals