1. Indications For Use  The PlumePen   Elite is designed for general electrosurgical  applications  including cutting and coagulation  and for removing smoke generated  by electrosurgery when used in conjunction with an effective smoke evacuation  system  The pencil enables the operator to remotely conduct an electrosurgical  current from the output connector of an electrosurgical unit to the operative site for  the desired surgical effect    Indications for Use for the PlumePen   Elite Integrated Smoke Evacuation Pencil  include    a  To remove smoke plume from the surgical site     b  To remotely conduct an electrosurgical current from the output connector of an  electrosurgical unit to the target tissue for the desired surgical effect     PlumePen      Elite    Surgical Plume Evacuation Pencil    If you have any questions or need any assistance with the set up  or use of the PlumePen   Elite Surgical Plume Evacuation Pencil  please contact Buffalo Filter   at    U S  toll free  800 343 2324   International  1 716 835 7000   Email  smoke info buffalofilter com    904162 RevB pdf    ee a     Figure 3    Plug the 3 prong power cord into the electrosurgical generator  of your choice   Figure 3   Confirm that all power settings on the  generator are appropriate for the procedure being performed   The electrosurgical generator   s intensity should be set as low   as isnecessary to achieve the desired effect  The PlumePen    Elite is a monopolar electrode  the use of a dispersive el
2. ectrode  is required to prevent burns injury to patient  Please refer to  electrosurgical generator user manual and dispersive electrode  instructions for use for additional instructions     Figure 2    Prior to connecting the PlumePen   Elite 3 prong  power cord to the electro surgical generator   ensure that the electrode blade  provided  is fully  inserted into the pencil by gently pressing it in  front of the PlumePen   Elite   Remove the plastic  shield from the blade and discard     Figure 1    Open product packaging and remove the  PlumePen   Elite Surgical Plume Evacuation  Pencil assembly  Connect the tubing provided  with the PlumePen   Elite to a smoke evacuation  system or other appropriate vacuum source   example shown   Figure 1   For connection and  operation to a specific smoke evacuation system   please refer to the specific instructions for use for  appropriate setup and use     Figure 6    To optimize the life of your smoke evacuation filter    it is recommended that a Buffalo Filter Surgical  Smoke Plume Evacuator be used in conjunction with  an EZLink    Automatic Activation Device  Model  EZLink0O1    Figure 6      Figure 5    The PlumePen   Elite has CUT and  COAG buttons located on the top of the  electrosurgical pencil body  The YELLOW  button is for cutting and the BLUE button is  for coagulation   Figure 5      Figure 4   The PlumePen   Elite is equipped with several key features for the    surgeon   s convenience  Above the electrode blade is a tra
3. ects  Current may be generated in conductive objects by direct    DO NOT activate the instrument when not in contact with target tissue  as this may cause contact with the active electrode  or by the active accessory being in close proximity    injuries due to capacitive coupling     PlumePen   Elite is designed and intended only to be used with an electrosurgical  generator that has been tested to the IEC 60601 standard  Please refer to generator to  ensure compatibility  PlumePen   Elite is not a fluid removal device  therefore  it should  not be used for such application     ASPIRATE fluid from the area before activating the instrument  Conductive fluids  e g    blood or saline  in direct contact with or in close proximity to an active electrode may         BUFFALO  Filter    5900 Genesee Street  Lancaster  NY 14086   U S  toll free 800 343 2324 International  1 716 835 7000  Fax  716 835 3414 Email  smoke info buffalofilter com  www buffalofilter com       to the conductive object     For single use only  Do not reuse  reprocess  or re sterilize  Reuse  reprocessing  or  re sterilization may compromise the structural integrity of the device and or lead to device  failure which in turn may result in patient injury  illness  or death     This single use product is not designed or validated to be reused  Reuse may cause a risk  of cross contamination or cause a malfunction as a result of the product being physically  damaged due to cleaning  disinfection  re sterilization  o
4. mePen Elite     If original blade is removed  visually confirm new blade is completely inserted and  secured before activating the pencil  Never force the blade into the pencil  Rotate the    INSPECT instruments and cables for damage prior to each use  especially pencil if the smoke tube is obstructing view of the insertion point     the insulation of laparoscopic endoscopic instruments  This may be done  visually under magnification or with a high voltage insulation testing  device  Insulation failures may result in burns or other injuries to the patient or operator     For procedures where visualization may be impaired  be alert of these potential hazards     e The electrode tip may remain hot enough to cause burns after the current has been  Sterility unless packaging is damaged or any seal is broken  Do not use electrosurgery de activated   in the presence of flammable anesthetics or other flammable gases  fluids  or objects   or in the presence of oxidizing agents  as fire may result  Place active accessories in a  holster or in a clean  dry  non conductive and highly visible area away from the patient  when not in use  Inadvertent contact with the patient may result in burns  Contact with    drapes or linens may cause a fire     Inadvertent activation or movement of the activated electrode outside of the field of  vision may result in injury to the patient     Localized burns to the patient or physician may result from electrical currents carried  through conductive obj
5. nslucent  plastic tube that can be positioned at varying lengths   Figure 4  to  most effectively capture surgical smoke plume as it is created     With the electrosurgical generator off and the electrode blade  cool  position this tube as near the point of the tissue interaction  as possible without obstructing the view of the target tissue   Keep the active electrodes clean  Build up of eschar may reduce  the instrument   s effectiveness  Do not activate the instrument  while cleaning  Injury to operating room personnel may result     The EZLink    will automatically turn the Buffalo Filter  Surgical Smoke Plume Evacuator on or turn it off  when either the CUT or COAG function is activated   de activated on the PlumePen   Elite   Contact Buffalo  Filter   for more details on the EZLink        After use  turn off smoke evacuation unit and  electrosurgical generator  Discard the entire  PlumePen   Elite assembly  Pencil  Blade   Tubing  and Power Cord  per facility protocol  for contaminated items     carry electrical current or heat away from target tissues  which may cause unintended  burns to the patient     CAUTION   DO NOT USE in patients who have electronic implants such as cardiac  pacemakers without first consulting a qualified professional  e g    cardiologist   A possible hazard exists because interference with the action  of the electronic implant may occur  or the implant may be damaged     Buffalo Filter recommends that the original blade be utilized with the Plu
6. r reuse        Do Not Use  Damaged    Single Use Only  Do Not Reuse    Do Not  er Resterilize    RX ony    cd us    Does Not  Contain Natural  Rubber Latex    STERILE R     PLP1001    REF PLP2001  PLP1501    PLP2501    CAUTION   Intended for use with a  maximum voltage of 10kV P P        
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
My Book Live User Manual  1 - KDDI  Formation de l`élève Cours 1 : Mesures et incertitudes Mode d`emploi  EasyView & e-Vision Manual  PHYSICS 3050 Electronics I Laboratory Manual Fall 2007  ACS BD Blender User Manual  Phantom 25 LED Wash  Sony VGN-FZ320E/B Marketing Specifications  PROBLÈME CAUSE PROBABLE SOLUTION Mauvaise adhésion de  Manual de usuario SSH    Copyright © All rights reserved. 