Home
        Instruction Manual
         Contents
1.    THE INDUSTRIAL NETWORK COMPANY    100 POE4  Unmanaged Industrial 4 Port  Mid Span POE PSE    User Manual  amp   Installation  Guide        Revised 2010 11 15        N IRON    THE INDUSTRIAL NETWORK COMPANY    Industrial 4 Port Mid Span POE PSE Installation Guide    100 POE4      N IRON       100 POE4 4         Revised 2010 11 15     Copyright     N TRON Corp   2008  820 S  University Blvd   Suite 4E  Mobile  AL USA 36609    All rights reserved  Reproduction  adaptation  or translation without prior written permission from N TRON  Corp  1s prohibited  except as allowed under copyright laws     Ethernet is a registered trademark of Xerox Corporation  All other product names  company names  logos  or other designations mentioned herein are trademarks of their respective owners     The information contained in this document is subject to change without notice  N TRON Corp  makes no  warranty of any kind with regard to this material  including  but not limited to  the implied warranties of  merchantability or fitness for a particular purpose  In no event shall N TRON Corp  be liable for any  incidental  special  indirect or consequential damages whatsoever included but not limited to lost profits  arising out of errors or omissions in this manual or the information contained herein     Contact Information      N TRON Corp    820 South University Blvd   Suite 4E   Mobile  AL 36609   TEL   251  342 2164  FAX   251  342 6353  Website  www n tron com    Email  N TRON_ Support  n tr
2.   OTHER HAZARDS  OR ACTS OF GOD     LIMITATION OF LIABILITY  TO THE FULL EXTENT ALLOWED BY LAW  N TRON ALSO EXCLUDES FOR ITSELF  AND ITS SUPPLIERS ANY LIABILITY  WHETHER BASED IN CONTRACT OR TORT  INCLUDING NEGLIGENCE    FOR INCIDENTAL  CONSEQUENTIAL  INDIRECT  SPECIAL  OR PUNITIVE DAMAGES OF ANY KIND  OR FOR  LOSS OF REVENUE OR PROFITS  LOSS OF BUSINESS  LOSS OF INFORMATION OR DATA  OR OTHER FINANCIAL  LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE  INSTALLATION  MAINTENANCE  USE   PERFORMANCE  FAILURE  OR INTERRUPTION OF ITS PRODUCTS  EVEN IF N TRON OR ITS AUTHORIZED  RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES  AND LIMITS ITS LIABILITY TO  REPAIR  REPLACEMENT  OR REFUND OF THE PURCHASE PRICE PAID  AT N TRON S OPTION  THIS DISCLAIMER  OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF  ITS ESSENTIAL PURPOSE     DISCLAIMER  Some countries  states  or provinces do not allow the exclusion or limitation of implied warranties or the  limitation of incidental or consequential damages for certain products supplied to consumers or the limitation of liability for  personal injury  so the above limitations and exclusions may be limited in their application to you  When the implied warranties  are not allowed to be excluded in their entirety  they will be limited to the duration of the applicable written warranty  This  warranty gives you specific legal rights which may vary depending on local law    GOVERNING LAW  This Limit
3.  polarity when installing power input cables  Reversing voltage  polarity can cause permanent damage to the unit and void the warranty      Revised 2010 11 15  4    HAZARDOUS LOCATION INSTALLATION REOUIREMENTS    1     This equipment is suitable for use in Class I  Div 2  Groups A  B  C  and D  or unclassified or non   hazardous locations only     WARNING  Explosion Hazard   Substitution of components may impair suitability for Class I   Division 2     WARNING  Explosion hazard  do not disconnect while the circuit is live or unless the area is known to be  non hazardous     WARNING  Explosion Hazard   Do not remove or replace the device unless power has been switched off  or the area is known to be non hazardous     Use 60 75  C rated Copper wire   0 22Nm  2 inch lbs Tightening torque for field installed connectors   WARNING  Install only in accordance with Local  amp  National Codes of Authorities Having Jurisdiction     Class I  Div 2 installations require that all devices connected to this product must be UL listed for the area in  which it is installed     WARNING  Damage may occur to the RJ 45 port of the powered device  PD   if the 100 POE4 is not  powered down before disconnecting the Cat5E cable      Revised 2010 11 15  5    Functional Overview    The 100 POE4 industrial 4 port Mid Span POE PSE is designed to provide power over Ethernet for POE  capable devices where running a power line is either not possible or not cost effective  This feature allows  an end user to
4.  power a POE camera  wireless access point  or any other POE capable device without the  need for running separate wires for power  This also allows the ability for a centralized battery backup for  all these devices     Key Features    Compact  space saving package  IEEE 802 3af Compliant  Four 10 100Base TX RJ 45 Ports  DATA IN   Four 10 100Base TX RJ 45 POE Ports  DATA  amp  POWER OUT   Unmanaged operation  Extended Environmental Specifications   40  C to 85  C Operating and Storage Temperature  Operating Humidity  10  to 90   Non Condensing   Full Wire Speed Communications  LED POE Status Indication  Power Fault Status LEDs  Up to 0 8 Gb s Maximum Throughput  Industry Standard 35mm DIN Rail Mounted Enclosure  Redundant power inputs  46 49 VDC   Supports up to 15 4Watts per channel  13 Watts at the Powered Device  PD     Hardened metal DIN Rail Enclosure        Revised 2010 11 15     PACKAGE CONTENTS    Please make sure the package contains the following items     1  100 POE4  2  Instruction Sheet    Contact your carrier if any items are damaged     UNPACKING    Remove all the equipment from the packaging  and store the packaging in a safe place  File any damage  claims with the carrier     CLEANING  Clean only with a damp cloth   INSTALLATION    Read the following warnings before beginning the installation     WARNING       Never install or work on electrical equipment or cabling during periods of lightning activity  Never connect  or disconnect power when hazardous gasse
5. E4    WARNING  Inserting the input plug while the 48VDC is applied may cause arcing  and damage  the input connector permanently     Verify the Power LED stays ON  GREEN     Note  Either V  or V2 can be connected to power for minimal operation  For redundant power  operation  V  and V2 plugs must be connected to separate DC Voltage sources  Use wire sizes of 20 10  gauge  The power cord should be limited to less than 10 meters in order to ensure optimum  performance    Recommended 48V DC Power Supplies  similar to     100 240VAC     N Tron NTPS 48 5  DC 48V 5A     Revised 2010 11 15  10    N TRON 100 POE4 MID SPAN POE GROUNDING TECHNIOUES    The grounding philosophy of any control system 1s an integral part of the design  N Tron switches are designed  to be grounded  but the user has been given the flexibility to float the switch when required  The best noise  immunity and emissions  i e  CE  are obtained when the N Tron switch chassis is connected to earth ground via  a drain wire  Some N Tron switches have metal din rail brackets that can ground the switch if the din rail is  grounded  In some cases  N Tron switches with metal brackets can be supplied with optional plastic brackets if  isolation is required     Users may run a drain wire  amp  lug from the screw provided on the back face of the  enclosure  In the event the provided grounding screw has been lost  care should  be taken to limit the penetration of the outer skin by less than 1 4   Failure to do  SO may cause i
6. e powered devices plugged into the 100 POE4     3  Verify that the POE light is on solid for the port in question   4  Verify cabling used between stations   The 100 POE4 15 a mid span PSE  not a POE switch    5  Verify that cabling is Category 3 or greater for 10Mbit Operation      Revised 2010 11 15  13    FCC STATEMENT    This product complies with Part 15 of the FCC A Rules    Operation is subject to the following conditions     1  This device may not cause harmful interference    2  This device must accept any interference received  including interference that may cause undesired  operation     NOTE  This equipment has been tested and found to comply with the limits for a Class A digital device   pursuant to Part 15 of the FCC Rules  These limits are designed to provide reasonable protection against  harmful interference in a residential installation  This equipment generates  uses  and can radiate radio  frequency energy and  if not installed and used in accordance with the instructions  may cause harmful  interference to radio communications  Operation of this device in a residential area is likely to cause  harmful interference in which case the user will be required to correct the interference at his own expense     INDUSTRY CANADA    This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment  Regulations  Operation is subject to the following two conditions   1  this device digital apparatus meets all  requirements of the Ca
7. ed Warranty shall be governed by the laws of the State of Delaware  U S A      Revised 2010 11 15     
8. ltitude     Network Media  10BaseT   100BaseT     Connectors  10 100BaseTX     3 5     8 89cm   1 489     3 78cm   3 53     8 96cm   0 7 Ibs   0 3 1kg   35mm    46 49 VDC   1 6 A   48 VDC  under full load    30 mA   48 VDC  under no load    27 Amp 1 5 ms   48VDC  under full load   24 Amp 1 5 ms   48VDC  under no load   Less than 100 mV   20 10 AWG     40  C to 85  C   40  C to 85  C  10  to 90   Non Condensing   0 to 10 000 ft      gt  Cat 3 Cable   gt  Cat 5 Cable    Eight  8  RJ45 TX Copper Ports    Recommended Minimum Wiring Clearance     Top  1   2 54 cm     Front  2     5 08 cm      Revised 2010 11 15     N TRON Limited Warranty    N TRON  Corp  warrants to the end user that this hardware product will be free from defects in workmanship and materials   under normal use and service  for the applicable warranty period from the date of purchase from N TRON or its authorized  reseller  If a product does not operate as warranted during the applicable warranty period  N TRON shall  at its option and  expense  repair the defective product or part  deliver to customer an eguivalent product or part to replace the defective item  or  refund to customer the purchase price paid for the defective product  All products that are replaced will become the property of  N TRON  Replacement products may be new or reconditioned  Any replaced or repaired product or part has a ninety  90  day  warranty or the remainder of the initial warranty period  whichever is longer  N TRON shall not be re
9. nadian Interference Causing Equipment Regulations  Operation is subject to the  following two conditions   1  this device may not cause harmful interference  and  2  this device must  accept any interference received  including interference that may cause undesired operation     Cet appareillage num  rique de la classe A r  pond a toutes les exigences de l interf  rence canadienne causant  des r  glements d   quipement  L op  ration est sujette aux deux conditions suivantes   1  ce dispositif peut ne  pas causer l interf  rence nocive  et  2  ce dispositif doit accepter n importe quelle interf  rence re  ue  y  compris l interference qui peut causer l op  ration peu d  sir  e      Revised 2010 11 15  14    Regulatory Approvals     Safety  UL Listed per ANSI ISA 12 12 01 2000  US and Canada  and is listed for use in Class I  Div 2  Groups  A  B  C  D  T4A    EMI  EN 61000 6 4  EN 55011   Class A  FCC Title 47  Part 15  Subpart B   Class A  ICES 003     Class A    EMS  EN 61000 6 2  IEC 61000 4 2  ESD   IEC 61000 4 3  RS   IEC 61000 4 4  EFT   IEC 61000 4 5  Surge   IEC 61000 4 6  Conducted Disturbances     Warranty  3 years from the date of purchase      Revised 2010 11 15  15    KEY SPECIFICATIONS    Physical  Height   Width   Depth   Weight   DIN Rail     Electrical   Input Voltage    Steady Input Current   Steady Input Current   Inrush Current     Input Ripple   Input Wire Size     Environmental  Operating Temperature   Storage Temperature   Operating Humidity   Operating A
10. on com     Revised 2010 11 15     GENERAL SAFETY WARNINGS    WARNING  Do not operate the equipment in the presence of flammable gasses or fumes  Operating  electrical equipment in such an environment constitutes a definite safety hazard     WARNING  Ifthe equipment is used in the manner not specified by N TRON Corp   the protection provided  by the equipment may be impaired     WARNING  Do not perform any services on the unit unless qualified to do so  Do not substitute  unauthorized parts or make unauthorized modifications to the unit     WARNING  Do not operate the unit with the end plates removed  as this could create a shock or fire  hazard     WARNING  Properly ground the unit before connecting anything else to the unit  Units not properly grounded  may result in a safety risk and could be hazardous and may void the warranty  See the grounding technique    section of this user manual for proper ways to ground the unit     WARNING  Do not operate the equipment in a manner not specified by this manual     ENVIRONMENTAL SAFETY WARNINGS       WARNING  Disconnect the power and allow to cool 5 minutes before touching     ELECTRICAL SAFETY WARNINGS       WARNING  Disconnect the power cable before removing the end plates   WARNING  Do not operate the unit with the end plates removed    WARNING  Do not work on equipment or cables during periods of lightning activity   WARNING  Do not perform any services on the unit unless qualified to do so     WARNING  Observe proper DC Voltage
11. ound   it is permissible to use fully shielded cables terminated to  chassis ground at both ends in systems void of low level analog signals      Revised 2010 11 15  11    RJ45 CONNECTOR CRIMP SPECIFICATIONS    Please reference the illustration below for your Cats cable specifications     0 232  0 005      5 89 0 1 27     CAT5e CABLE    EIA 568B    0 237  0 005   6 02 0 1 3     CATSe CABLE        Revised 2010 11 15        TYPICAL APPLICATION    Utility Power    Factory Switch    N TRON 7014Fx2  1 5 7 9          48VDC 48VDC  N TRON NITRON  5 Amp 5 Amp                LAN  Devices  Wireless   Devices       POE  Print Server       A sv NA Ji  Essl LF SF      Scanner                     Printer  ewe CAT5e Cable  CAT5e Cable with POE  amme 48VDC Power       Receiving POE  Dock RFID Reader e  Shipping  Dock  CONNECTING THE UNIT    For 10Base T ports  plug a Category 3  or greater  twisted pair cable into the RJ45 connector  For  100Base T ports  plug a Category 5  or greater  twisted pair cable into the RJ45 connector  Connect the  other end to the far end station  The total length of cable should not exceed 100 meters  Although power is  being applied to the Ethernet port  the power does not boost data on the lines     TROUBLESHOOTING  1  Make sure the     Power LED  is ON     2  Make sure you are supplying sufficient current for the 100 POE4 and all the powered devices plugged  into it  Note  The inrush current and steady state current is dependent on the power requirements  of th
12. replacement is provided and customer fails to return the original product to N TRON within fifteen  15  days after  shipment of the replacement  N TRON will charge customer for the replacement product  at list price     WARRANTIES EXCLUSIVE  IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE   CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR  REPLACEMENT  OR  REFUND OF THE PURCHASE PRICE PAID  AT N TRON S OPTION  TO THE FULL EXTENT ALLOWED BY LAW  THE  FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES   TERMS  OR CONDITIONS  EXPRESS OR IMPLIED  EITHER IN FACT OR BY OPERATION OF LAW  STATUTORY OR  OTHERWISE  INCLUDING WARRANTIES  TERMS  OR CONDITIONS OF MERCHANTABILITY  FITNESS FOR A  PARTICULAR PURPOSE  SATISFACTORY QUALITY  CORRESPONDENCE WITH DESCRIPTION  AND NON   INFRINGEMENT  ALL OF WHICH ARE EXPRESSLY DISCLAIMED  N TRON NEITHER ASSUMES NOR AUTHORIZES  ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE   INSTALLATION  MAINTENANCE OR USE OF ITS PRODUCTS  N TRON SHALL NOT BE LIABLE UNDER THIS  WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION  IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSON S MISUSE   NEGLECT  IMPROPER INSTALLATION OR TESTING  UNAUTHORIZED ATTEMPTS TO OPEN  REPAIR OR MODIFY  THE PRODUCT  OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE  OR BY ACCIDENT  FIRE   LIGHTNING  POWER CUTS OR OUTAGES
13. rreversible damage to the internal components of the switch     Note  Ensure the power supply is grounded properly before applying power to the  grounded switch  This may be verified by using a voltmeter to determine that  DRAIN WIRE WITH LUGS there is no voltage difference between the power supply   s negative output terminal  TO KNOWN GROUNDING POINT and the chassis grounding point of the switch     a NONMETALLIC DIN RAIL  MOUNT             As an alternative grounding method  both V  legs of the power input  connector are connected to chassis internally on the PCB  Connecting  a drain wire to earth ground from one of the V  terminal plugs as  shown here will ground the switch and the chassis  The power leads  from the power source should be limited to 3 meters or less in length         DRAIN WIRE WITH LUG  CONNECTING SWITCH CHASSIS  TO KNOWN GROUNDING POINT    If the use of shielded cables is required  it is generally recommended to only connect the shield at one end to  prevent ground loops and interfere with low level signals  i e  thermocouples  RTD  etc    Cat5e cables  manufactured to EIA 568A or 568B specifications are required for use with N Tron Switches     METALLIC NONMETALLIC  TT     SHIELDED PATCH CABLE  STP         tate  S       a  sae see   ee    Note  Strain relief boots not shown for clarity purposes   In the event all Catse patch cable distances are small  i e  All Ethernet devices are located the same local    cabinet and or referenced to the same earth gr
14. s are present      Revised 2010 11 15     DIN Rail Mounting    Install the unit in a standard DIN rail  Recess the unit to allow at least 2    of horizontal clearance for CATSe    cable bend radius            lt x       To install the unit to 35mm industrial DIN rail   place the top edge of the included mounting  bracket on the back of the unit against the DIN  rail at a 15   angle as shown  Rotate the bottom of  the unit to the back  away from you  until it  snaps into place            Revised 2010 11 15        To remove the unit from the 35mm industrial  DIN rail  place a flat head screwdriver into the  release clip found at the bottom of the unit  and  apply downward force on the clip until it  disengages from the bottom of the unit from the  DIN rail  Rotate the bottom of the unit towards  you and up at an approximate 15   upward angle  to completely remove the unit     Most N Tron    products are  designed to be mounted on industry  standard 35mm DIN rail  However   DIN rail mounting may not be  suitable for all applications  Our  Universal Rack Mount Kit  P N   URMK  may be used to mount the  100 POE4 enclosures to standard 19   racks as an option        FRONT PANEL    100 POE4 OO       From Top to Bottom       Power LED  V1 POE POE is being applied on the respective port with V1 as a valid source of power   V2 POE is being applied on the respective port with V2 as a valid source of power     LEDs  The table below describes the operating modes  Port LEDs are for power s
15. sponsible for any custom  software or firmware  configuration information  or memory data of customer contained in  stored on  or integrated with any  products returned to N TRON pursuant to any warranty     OBTAINING WARRANTY SERVICE  Customer must contact N TRON within the applicable warranty period to obtain  warranty service authorization  Dated proof of purchase from N TRON or its authorized reseller may be required  Products  returned to N TRON must be pre authorized by N TRON with a Return Material Authorization  RMA  number marked on the  outside of the package  and sent prepaid and packaged appropriately for safe shipment  Responsibility for loss or damage does not  transfer to N TRON until the returned item is received by N TRON  The repaired or replaced item will be shipped to the  customer  at N TRON   s expense  not later than thirty  30  days after N TRON receives the product  N TRON shall not be  responsible for any software  firmware  information  or memory date of customer contained in  stored on  or integrated with any  products returned to N TRON for repair  whether under warranty or not     ADVANCE REPLACEMENT OPTION  Upon registration  this product qualifies for advance replacement  A replacement  product will be shipped within three  3  days after verification by N TRON that the product is considered defective  The  shipment of advance replacement products is subject to local legal requirements and may not be available in all locations  When  an advance 
16. upply status only and  do NOT indicate link or activity      LED  O    Green Valid Power  46 54 VDC  is applied    Invalid Power   lt 46 VDC  is applied or Power Bus Fault detected    OFF No Power is applied to the device  POE is being applied on the respective port with V1 as a valid  source of power    Blinking   POE PD detected with improper power classification    a    POE    OFF POE is not being applied on the respective port from the V1 power  input    Green POE is being applied on the respective port with V2 as a valid  source of power  Blinking   POE PD detected with improper power classification    OFF POE is not being applied on the respective port from the V2 power  input    V2  POE       5   DO O  5         Note  Redundant power inputs will not balance the power load  Only load from one power supply is used  at a time      Revised 2010 11 15     APPLYING POWER  Top View     All     tt CHASSIS GROUND N    7 aa amen mmm on mm X            Negative GND Return   V     Positive 46 54VDC        Negative GND Return   V    Positive 46 54VDC     DETAIL Fi            Unscrew  amp  Remove the DC Voltage Input Plug from the top header    Install the DC Power Cables into the Plug  observing polarity on unit     Plug the Voltage Input Plug back into the top header    Tightening torque for the terminal block power plug is 0 22 Nm 0 162 Pound Foot    Turn the power on the wire    Note  It is only safe to turn the power on the wires after the wires have been secured to the  100 PO
    