Home

BioWin 3

image

Contents

1. Your BioWin lease will expire in X days Contact EnviroSim to renew your lease now Your lease will expire in the specified number of days Your BioWin lease was successfully updated The lease code that you entered was accepted by BioWin and your lease date has been updated Your BioWin lease was successfully updated An updated version is available The lease code that you entered was accepted by BioWin and your lease date has been updated A newer version of the BioWin software is available Code appears to be mistyped please check The code that you entered is incorrect for the key that you are using or has been mistyped Program file appears corrupted The BioWin executable file appears to be corrupt please contact EnviroSim Purchased version BioWin Code entered for older version The activation code entered is only valid for the version of BioWin purchased Hardlock key search information If your If your system has difficulty in finding the Hardlock key there are a number of environment variables that can be used to address these difficulties The environment variables allow you to specifically use the port on which the key is installed change the network search options and control retries and timeouts The section Setting Environment Variables in the document hlendusersmanual_en pdf located in the MANUAL directory on the installation CD ROM describes the use of env
2. ates precipitation Fe Precipitation Modified Vesi Status Steady state solution SRT days 61 84 Ready to simulate 20 0 C 1 0 hours Current alarms 0 e Cyclone elements Two new process flowsheet elements have been added to BioWin for the simulation of cyclone separation processes an ISS cyclone and a Dewatering DW cyclone These units are used in Cannibal type systems for preferential removal of inorganic suspended solids ISS which are present in the influent and that accumulate in the mixed liquor In practice the underflow from a cyclone typically is in the range of 20 to 40 percent of the unit input flow but the underflow is directed onto an inclined belt the objective is to largely dewater the underflow leaving behind mainly grit with a high ISS content For each cyclone element the user specifies the flow split by adjusting the flow split the user can modify the solids of the so called grit 1 With the ISS cyclone the user specifies the capture of inert suspended solids ISS The concentrations of other particulate components are the same in the overflow and underflow 2 In Cannibal type applications the cyclone is used in conjunction with dewatering With the Dewatering DW cyclone the user specifies the percent solids capture and the additional capture of ISS Adjusting the two capture rates allows the user to modify the VSS TSS composition of the grit The two cyclone
3. Denitrification by heterotrophs ordinary heterotrophic organisms OHOs phosphorus accumulating organisms PAOs or methanol utilizing heterotrophs methylotrophs is modeled as a two step process with conversion of nitrate to nitrite and then nitrogen gas Modeling the growth of Anammox bacteria autotrophic organisms that combine ammonia and nitrite to form nitrogen gas without the addition of organic substrate For further details review the Sidestream chapter Usability Enhancements A number of features have been added to BioWin to streamline ease of use Version 3 1 new features Upgraded simplified and more consistent dialogs for setting up parameter plots Improved table displays with options to show element specific variables for different element types concentrations and or mass rates as well as column totals New tables replace aeration tables with the added ability to show and sum aeration details for different element types Ability to duplicate Album pages including charts and series tables and element info displays but excluding any functions Flow option of gal d for small flow elements in U S customary units Auto save BioWin files while you are working on them in addition to dynamic simulation intermediate files Function series that allows a BioWin series to be multiplied by a constant Function periods can be specified as time intervals rather than number of points Ability to monitor plot SBR liquid dep
4. and then double click the following folders in sequence Program Files EnviroSim BioWin 3 Images Click the OK button 8 Click Close to shut the Advanced dialog box and then click Close to shut the Tools Customize dialog box 9 Shut down BioWin and then restart Everything should now be working fine Appendix 2 Hardlock information General The Aladdin Hardlock End User s Manual is in the document hlendusersmanual_en pdf which is located in the MANUAL directory on the installation CD ROM The document hlendusersmanual_en pdf contains detailed information about the Hardlock module installations procedures and trouble shooting information If you have purchased a server version of the software the document also describes the HL Server and utility software Hardlock USB key status information Hardlock USB is equipped with an LED display which shows the status of the protection module LED display Status LED does not light The module is not recognized Possible reasons No driver no USB support module not functioning LED flashes at approx 2 Hz The module is recognized but not initialized correctly Possible reasons Memory defective module not encoded as a Hardlock module module not functioning LED lights up The module is recognized and initialized correctly If your USB key LED is steadily lit then the hardware should be functioning correctly and it is like that your
5. content Bicarbonate C Composite samples Carbonaceous OUR Carbonate Dissolved N2 gas production rate E Unionized ortho P C Surface plot Nisenlved M nae ntadiction rate nar r HPNA Elements Selected elements E Elements Bioreactor COD Influent E Effluent E Model clarifier H Sludge E Splitter Plot selected K A Some of the additions changes and upgrades in BioWin 3 1 are listed here A number of the features added to BioWin Version 3 0 are also listed as a reminder to users Linking to BioWin Controller BW Controller is a separate Windows application which links to a BioWin configuration and allows specification of a range of process control features commonly employed in wastewater treatment systems Start BW Controller To start click on the Start BW Controller button at the right on the toolbar in BioWin to link the control application to the BioWin configuration BW Controller includes its own Help and Tutorials Model Additions and Enhancements The additions to the Full Plant Edition of BioWin are significant advances in modeling of wastewater treatment plants BioWin tracks more organic and inorganic components than any other simulator and allows a complete mass balance for recycled sidestreams and supernatants The integrated process model in BioWin works for any environmental condition whether in aerated or unaerated activated sludge tanks fermenters sidestream reactors or digesters This allows s
6. having a hardcopy may be easier for the initial step After you install there is a document called TUTEXAM PDF in the MISC subdirectory of the BIOWIN directory Alternatively look on the CD in the MANUAL directory Appendix 1 Potential Technical Installation Issues Potential Issue 1 Error Message during Installation Failed to start a service in the Service Control Manager Database When running the BioWin installation program or the hardlock installation program hldrv32 exe users may get the error Failed to start a service in the Service Control Manager Database Please visit FAQ on the EnviroSim website http www envirosim com support fag php faq14 where you can dowload the files needed to resolve this issue Potential Issue 2 Hardlock Issues in Windows A small number of users have experienced problems accessing the Hardlock key In cases where this has occurred the following procedure resolved the problem The search for the Hardlock key needs to be expanded To accomplish this one of the following environmental variables needs to be set SET HL_SEARCH 278i 378i 3BCi or SET HL_SEARCH 278e 378e 3BCe i is for bi directional port and e is for ECP EPP ports Also the HL_SEARCH variable directs the Hardlock software to search the local port instead of the local port and the network for a Hardlock To set these environmental variables in Windows 2000 follow the procedure listed below 1 Click Star
7. problem is not related to the installation of your key BioWin Hardlock key messages BioWin error message Possible reasons Error Unable to find Key 1 The key is not plugged in or could not be found HARDLOCK VXD or HARDLOCK SYS OR 2 The key driver software is not properly installed All network licenses in use 3 If you have a server version of the software then either the Hardlock server cannot be found or all the licenses are in use Error Network error 1 If you do not have the server version then key cannot be found 2 If you have a server version of the software then an error in network operation remote was detected This may occur for example if no protocol such as IPX or NetBios is loaded in the local client system Error Accessing required driver A required driver cannot be opened The problem is usually that the driver is not installed Error Too many users The maximum number of users has been reached Error Invalid environment settings The specified environment variable for the API search sequence contains only incorrect entries Error Version mismatch HLVDD DLL During communication the system determined that the HL Server or an installed Hardlock driver is not compatible with the API version being used BioWin Lease Messages Possible Reasons LEASE EXPIRED Your lease period has come to an end contact EnviroSim for a lease renewal
8. McMaster Innovation Park 114A 175 Longwood Road South Hamilton Ontario Canada L8P OA1 P 905 481 2607 EnviroSim F 905 481 2610 ASSOCIATES LTD www enviroSim com Installing BioWin 1 Older Versions of BioWin BioWin 3 1 will be installed as an upgrade to BioWin 3 That is it will install over the top of your existing BioWin 3 installation Please note that this upgrade will not affect older BioWin versions BioWin 2 2 and earlier which are separate applications this means that users can keep their older BioWin 2 2 and earlier copies of BioWin 2 Installation Do NOT plug the Hardlock Aladdin key into your computer until the installation is complete You must have Administrator privileges to install the software e Insert the CD into the CD drive Installation should start automatically If installation does not begin after several seconds e Click START and select Run e Type D BW30SETUP exe if your CD drive is another letter replace D with that letter Click OK to start installation e Follow the instructions on the screen 3 Hardlock After installation and every time you want to run BioWin you must plug the Hardlock Aladdin key into your PC Different types of keys that may ship with your copy of BioWin are shown below Different types of Hardlock keys from left to right Network version parallel port key plugs into parallel port standard parallel port key plugs into parallel port U
9. SB key plugs into USB port and PCMCIA key plugs into PCMCIA slot The Hardlock USB is equipped with an LED which shows the status of the protection module If you are using the USB key and after you plug the Hardlock Aladdin key into the USB port the LED does not light up or if it flashes see the section Hardlock USB key status information in Appendix 2 Lease Activation Code When you first run BioWin after installing you will be prompted to enter a Lease Activation Code This is located on a sticker on the back of the CD case Type the code in and press the Apply Lease Code button note that the code is NOT case sensitive A common error is pressing the OK button instead of the Apply Lease Code button Help BioWin employs the latest in Help delivery technology HTML help This launches with a look and feel consistent with Microsoft Office products For tips on using this effectively look in the Help under the Getting Help in BioWin chapter Manual BioWin does not ship with a printed manual However if you want to print the manual it has been shipped as an Adobe PDF This document can be found on your PC in the MISC subdirectory of the BIOWIN directory which in turn is probably a subdirectory of PROGRAM FILES ENVIROSIM directory depending on where you installed Getting started A good starting point is to print out the Tutorials chapter and use this to get familiar with BioWin It s all in the Help but
10. e series and from a separate tab Improvements have also been made to the interface for setting up tables Previously there were separate options for setting up tables of flows concentrations mass rates and aeration details These have now been merged into a single Table editor and concentrations and mass rates can be shown in the same table A facility to totalize columns in tables also has been added r 7 M Add parameters for plotting i aq tll Time series Current value Special Functions Imported General plot Combined State variables Selected variables Alkalinity a Non polyP heterotrophs A Filtered Carbonaceous BOD Anoxic methanol utilizers Filtered COD Ammonia oxidizing biomass Filtered TKN Nitrite oxidizing biomass Nitrite Nitrate Anaerobic ammonia oxidizers Particulate COD PolyP heteratrophs Particulate TKN Propionic acetogens pH Acetoclastic methanogens Soluble PO4 P Hydrogenotrophic methanogel Total Carbonaceous BOD Endogenous products Total COD Slowly bio COD part Total inorganic N Slowly bio COD colloid Total inorganic suspended solids X Part inert COD Element specific Water chemistry Duplicates of aerators a pH A of diffusers lonized ammonium Plat Type Actual DO sat cone Unionized ammonia Concentration flows Air flow rate diffuser Nitrous acid Air supply rate Nitrite i C Mass rates Ammonia content Total dissolved CO2 Carbon dioxide
11. eamless integration of the processes in the whole plant A few Version 3 1 highlights e MBR element A new process flowsheet element has been added for membrane bioreactors MBRs The MBR unit shown below has two output streams one for permeate and one for mixed liquor from the MBR tank wastage or recycle to upstream reactors The user specifies either the number of membrane modules with editable membrane area and displaced volume per module or the packing density membrane area per unit tank volume for coarse bubble aeration Default aeration parameters are set to values typical File Edit Tools Project iew Simulate Help DB S SIRMHB av eo a s ie Main Configure J Calculators Influent Ee gt gt Hy m Name MBR Type Membrane bioreactor HRT 34 hours S_NHx 0 23 mgN L i Volume 19350 m _NO3 28 31 moN L I Area 63 48 m2 S_NO2 0 05 mgN L Depth 305 m SP04 7 26 mgP L of Cassettes 10 00 cassetes vss 6276 mgvSS L Membrane displaced volume 16 90 m TSS 9281 mgTSS L Membrane suface area 15168 00 m2 ap T mo p Packing density 78 39 m2 m3 Membrane fius 1 22 Lim2she Mined liquor fow 757 mad our 47 55 moD L tr OTR 851 kg hr Qottgas dy 230365 m3 hr Power dissipation Mech mixing 5 00 W m Airflow 110 78 W m Velocity gradient 349 35 EE Model options BisWinAS AD model Builder model Oxygen modeling pH calculation pH limitation inAS St
12. eeds to initialize certain settings This tells you how to resolve this problem this assumes you have accepted the default file location settings during the installation if you installed to YourDirectory instead of Program Files then substitute YourDirectory in the instructions below 1 Choose the Tools Customize menu command and click on the File locations tab Ignore any errors that BioWin gives you while you do this 2 Click on Data files and click the Modify location button Double click on the C folder icon and then double click the following folders in sequence Program Files EnviroSim BioWin 3 Data Click the OK button 3 Click on Album pages and click the Modify location button Double click on the C folder icon and then double click the following folders in sequence Program Files EnviroSim BioWin 3 Templates Click the OK button 4 Click on Chart files and click the Modify location button Double click on the C folder icon and then double click the following folders in sequence Program Files EnviroSim BioWin 3 Misc Click the OK button 5 Now click on the Advanced button Click on Binary files and click the Modify location button Double click on the C folder icon and then double click the following folders in sequence Program Files EnviroSim BioWin 3 Application Click the OK button 7 Click on Flowsheet image files and click the Modify location button Double click on the C folder icon
13. elements can be used to achieve the same results namely a flow of grit with a certain VSS TSS composition The ISS cyclone element is provided for users who wish to simulate cyclone operation without dewatering of the underflow e FastSBR Sequencing Batch Reactors SBRs enjoy a wide application in wastewater treatment and BioWin offers a quasi two dimensional approach that is able to simulate situations where quiescent settling is disrupted by flow conditions All this modeling strength comes at a cost more complex and time consuming simulations particularly since the dynamic nature of SBRs means that steady state solution techniques are not appropriate Modeling of the settling phase is particularly intensive because the concentrations of the many particulate components may change slightly as a result of reactions but the settling rate is a function of TSS concentration a composite of many particulates Version 3 1 introduces a fast approximate technique that can allow you to get reasonably close to the solution fast and then turn on the more rigorous modeling to refine your simulations or to ensure that the approximate method reasonable accurately represent the full model Many of the competitors only offer only a 1 dimensional approximate technique In Version 3 1 the settling phase in an SBR can be modeled at three different levels of complexity 1 Reactive BioWin considers all state variables all biological and chemical reaction
14. ironment variables Created by process engineers for process engineers New Developments in BioWin The latest version of BioWin provides a host of additions and improvements to enhance your wastewater treatment plant simulations The main additions to Version 3 1 in terms of modeling capacity are e MBR element e Microscreen element e Two cyclone elements ISS cyclone and Dewatering cyclone e Fast SBR model e IWA naming as an option Version 3 1 includes many usability improvements in addition to the model extensions Examples include the facility to specify flows in units of gallons per day useful for specifying small flows for say chemical addition inputs when the selected unit basis is US units automated file backup simplified editing of pipe properties the facility to duplicate pages in the Album by right clicking on the page tab and many more One significant usability improvement is the new interface for adding charts in the Album Previously when one selected the Add Chart function the resulting dialog had 11 tabs for example Time Series Multi Time Series Mass rates etc The new dialog shown below has been simplified considerably and features have been added The dialog now only has 6 tabs and there is more uniformity between the Time series and Current value tabs In each case plots of flows concentrations or mass rates are generated from one dialog Previously mass rate plots could only be generated for tim
15. ruvite amp Ca Phosphates precipitation Fe Precipitation Modified Vesi Status Steady state solution SRT days 2333 Ready to simulate 200 1 0 hous Curent alarms 0 J Microscreen element A new process flowsheet element has been added for microscreens Units with mesh sizes of say 200 to 300 microns are used in Cannibal type systems for screening a portion of the RAS flow see example configuration below Experience indicates that these units preferentially screen out unbiodegradable inert particulate VSS XI from the mixed liquor The user specifies the flow split for the unit by adjusting the flow split the user can modify the solids of the so called trash The user also specifies the percent solids capture and the additional capture of volatile particulate inerts trash fE BioWin Simulator File Edit Tools Project View Simulate Help OSS SKB A vyol Als ioe Adjusting the two capture rates allows the user to modify the VSS TSS composition of the Configure Calculators Main Influent Aerobic Effluent Interchange Microscreen ISS Cyclone m Name Trash Type Sludge Flow TSS VSS as of TSS Nas of TSS Pas of TSS pH TSS VSS FZ Model options BioWin AS AD model Builder model Oxygen modeling pH calculation pH limitation in AS Struvite amp Ca Phosph 247 m3 d 354 95 76 6 38 200 668 875 57 kg d 838 42 kg d
16. s as well as pH in all cells during the settling periods 2 Non reactive BioWin still considers all state variables and includes pH calculations however BioWin ignores biological and kinetic chemical reactions during the settling phase 3 Fast BioWin consider only solids settling equations in all cells during settling modes e IWA naming convention BioWin 3 1 now allows a third state variable naming convention the IWA naming option displays names according to the IWA draft specification This option is selected through the Tools Customize menu Version 3 highlights e Development of a sophisticated biofilm model This has been implemented initially only for Media Bioreactors that is activated sludge suspended growth reactors that contain a free floating carrier media for biofilm growth e g integrated fixed film activated sludge IFAS and moving bed bioreactor MBBR systems The Media Bioreactor module also can be used to configure reasonable representations for other biofilm systems such as trickling filters biological aerated filters and tertiary denitrification filters For further details on the biofilm model review the Biofilm chapter Modeling nitrification as a two step process that is conversion of ammonia to nitrite NO2 mediated by ammonia oxidizing bacteria AOBs and conversion of nitrite to nitrate NO3 mediated by nitrite oxidizing bacteria NOBs For further details review the Sidestream chapter
17. t Settings Control Panel Double click the System icon Click the Advanced tab Click the Environment Variables button Ye eI In the User variables for user currently logged on this computer e g administrator section click the New button 6 Inthe Variable Name text edit box type SET HL_SEARCH In the Variable Value text edit box type 278i 378i 3BCi or 278e 378e 3BCe depending on the type of ports that you have We recommend that you consult your IT staff if you are unsure of this information Potential Issue 3 Device Drivers When running the BioWin installation program or the hardlock installation program hldrv32 exe am getting the error Failed to start a service in the Service Control Manager Database It is possible that the device drivers installed on your machine are out of date Download the latest drivers here http www envirosim com BWUN ver 2_1 sa hli hl_devdr exe Save the file hl_devdr exe to a location of your choice Double click on hl_devdr exe and follow the wizard that will guide you through the whole process Potential Issue 4 Running for the first time on Windows NT 2000 only do this if you have problems You may encounter a problem with initially running BioWin on machines with Windows NT 2000 This tells you how to resolve the problem When you first start BioWin you may get an Error Opening File this is because BioWin is unable to locate the desktop file that it n
18. th and sludge blanket height Simplified rates window display Improved dynamic simulation speed Features added in Version 3 In ideal separation devices point settlers dewatering units and ideal clarifiers a schedule can be defined to specify time varying percentage removals Oxygen transfer calculations are based on diffuser submergence rather than tank depth When setting up charts in the Album the list of variables that can be plotted is very extensive These have been grouped in separate category lists state variables combined variables water chemistry variables commonly plotted variables This simplifies selecting variables to plot Improved numerical solution techniques and more simulation method options The facility to plot profiles of variable concentrations through layers in the biofilm in Media Bioreactors Itineraries are now completely independent of the constant value Additional alarms to alert the user to unusual conditions Thread process priority management for BioWin users The ability to specify project start time from the project info dialog box Improved grid snap methods Oxygen transfer through the surface in anoxic zones Improved fly by panels The facility to include exclude media from media reactors

Download Pdf Manuals

image

Related Search

Related Contents

Appunti EUCIP IT ADMINISTRATOR Modulo 1 PC Hardware  main manual  KV-32DS60U  おかげさまで エコシリーズ 累計300万個 出荷!!  Jena SQUID System  termotronica energie rinnovabili thermotronique énergies  SAS to SAS/SATA JBOD Subsystem User Manual  Garmin echoMAP 71sv Installation Instructions  Model 6036・6035  Powermax45 Pressure Sensor Cable Replacement  