86A152FG01-bullx B5xx system Hardware
Contents
1. SNMP version 1 default value 2 3 SNMP community default value public SNMP port default value is 161 SNMP timeout default value is 20 SSH connection timeout default value is 30s Output file name where stdout and stderr outputs are redirected Displays ALL the FRUs linked to the modules on which the domain is defined bullx B5xx system Hardware Management CLI Reference Guide 1 3 3 1 3 3 1 1 3 4 1 3 5 Usage bullx blade chassis Syntax bsmfru sh h m CMC H host u user p password o outfile 1 level Display FRUs Command bsmfru sh m CMC H 129 184 238 254 u root p pass FRU System Description FRU System Description CMB_Chassis ID 2 on MC 0x20 Board Mfg Date Sat Mar 14 11 57 00 2009 Board Mfg Sanmina SCI Board Product LCP chassis Board Serial E86C0910014 Board Part Number WP11011500 C Board Extra 0 Board Extra 0 Board Extra DVT Board Extra 0 Board Extra WP11011500 C Board Extra BULL Usage bullx blade servers Syntax bsmfru sh h m blade_CMC H host u user p password o outfile 1 level Usage Server using ipmidrv model Syntax bsmfru sh h m ipmidrv o outfile 1 level Chapter 1 CLI command for bullx blades 1 9 1 4 1 4 1 1 4 2 1 10 bsmFWupg bsmFWupg is used to upgrade using an external tool the firmware of Remote Management Modules Operations that can be done bsmFWupg a b
2. BMC user for NovaScale target servers using the ipmilan model bullx chassis bullx blades User for ssh connection to the HMC for PL servers Identity key file used to perform connection to the HMC with ssh ssh client configuration file used to perform non prompt connection to the HMC Directory where identity key file and ssh client configuration file are installed default value is etc ssh Type of events to list Valid values are console or hardware default value User password Authentication key for Express5800 servers Cipher suite ID to be used by lanplus interface default is 3 Blade name for Blade servers or managed system name CECname for PL servers SNMP version 1 default value 2 3 SNMP community default value is public for reading the log and private for clearing the log SNMP port default value is 161 Chapter 1 CLI command for bullx blades 1 45 T timeout SNMP timeout default value is 20 SSH connection timeout default value is 120s o outfile Output file to which stdout and stderr outputs are redirected c Clears the SEL for NovaScale servers using the ipmilan or ipmidrv model 1 46 bullx B5xx system Hardware Management CLI Reference Guide 1 10 3 1 10 4 1 10 5 Usage bullx blade chassis bsmlog is also used to clear the system log contents SEL on NovaScale and Evolutive Line Blade servers NovaScale servers using the ipmilan or ipmidrv model bullx
3. x tempLimit Options i policylD Policy ID x tempLimit Temperature Limit used as Policy Trigger value Command bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a setTempTrigger i 1 x 85 1 7 3 14 Set the Min and Max power consumption range The setNMPowerDrawrange action is used to set the Min and Max power consumption range Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a setNMPowerDrawRange n minPower N mawPower Options n minPower Minimum Power Draw in Watts N maxPower Maximum Power Draw in Watts Command Output 1 30 bullx B5xx system Hardware Management CLI Reference Guide 1 7 3 15 1 7 3 16 Get the Node Manager Power Statistics The getNMStatistics action is used to get the Node Manager Power Statistics Syntax bsmHWpm sh h 1l level m model H host u user p password o outfile z ME channel e ME address a getNMStatistics O mode i policyID Options O mode Specifies the type of statistics to be collected 1 global power statistics in Watts 2 global inlet temperature statistics in Celsius 17 per policy power statistics in Watts 18 per policy trigger statistics in Celsius i policylD This argument is mandatory only if mode argument is set to 17 or 18 Command bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a getNMStatistics O 1 Node Mana
4. 1 level m model H host u user p password o outfile M generation a getLan Options M generation Model generation For novascale NS4xxF2 model model generation must be F Command bsmHWpm sh m lanplus H 199 182 100 160 u root p bull M F a getLan Obtain the share type for the active Ethernet port used by the BMC The getActivLan action displays the share type for the active Ethernet port used by the BMC The possible value are dedicated shared shared with failover lom2 shared with failover all loms Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile M generation a getActiveLan Options M generation Model generation For novascale NS4xxF2 model model generation must be F Command bsmHWpm sh m lanplus H 199 182 100 160 u root p bull M F a getActiveLan 1 38 bullx B5xx system Hardware Management CLI Reference Guide 1 7 3 29 Get servers ethernet port s MAC addresses The getMac action is used to obtain the MAC addresses of the server Ethernet ports and in particular the BMC ones This action can be used only if an iDRAC card is present Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile M generation a getMac Options M generation Model generation For novascale NS4xxF2 model model generation must be F Command bsmHWpm sh m lanplus H 199 182 100 160 u root p bull M F
5. PET ACK timeout retry 25 Retries 3 IP address 129 182 6 22 MAC address 00 11 2 33 44 55 Status Enabled Alert policy table entry 2 Chapter 1 CLI command for bullx blades 1 19 1 6 47 1 20 Get information about the Platform Event Filter Table Command bsmHWinfocmd sh a get_pef_list m ipmilan H 129 182 6 151 u MWA p guest PEF table entry Status Version Sensor type Sensor number Event severity Event class Event trigger s Action Policy set PEF table entry Status PEF table entry Status Version Sensor type Sensor number Event severity Event class Event trigger s Action Policy set active 0x11 Any Any Warning Threshold 0x01 0x0081 lt LNC lt UNC Alert 1 2 inactive 3 active 0x11 Power Supply Any Critical Discrete Sensor specific Alert bullx B5xx system Hardware Management CLI Reference Guide 17 1 7 1 bsmHWpm The bsmHWpm command is available for servers with Manageability Engine This command is used to control power consumption of platform using power and thermal policies getPowerBudget setPowerBudget bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bsmHWpm sh bs
6. for CMM and Local Control Panel IBS for IB Switch blade panel ESM for Ethernet Switch Module panel UCM for Ultra capacitor Module bullx blade index bullx blade slot bullx chassis CMC IP address BMC user User password Cipher suite ID to be used by lanplus interface default is 3 Output file name where stdout and stderr outputs are redirected SNMP version 1 default value 2 3 SNMP community for SNMP writing SNMP port default value is 161 SNMP timeout default value is 20 bullx B5xx system Hardware Management CLI Reference Guide 1 8 2 Usage bullx blade chassis amp bullx blade servers Notes e For bullx chassis and blades if the B targetname option is not set then the B LCPCMM option is used Syntax bsmidentify sh h m CMC M hwmanager B targetname I index C value U community S SNMPv P port T timeout o outfile 1 8 3 Usage Server using ipmidrv model Syntax bsmidentify sh h m ipmidrv 1l level C value o outfile Chapter 1 CLI command for bullx blades 1 4 1 9 1 9 1 1 9 2 1 42 bsminfo bsminfo sh is used to direct to the standard output the configuration information specified in the i information parameter When the command is accepted the return code is O If the command fails the return code is 1 Notes e This command concerns NovaScale 5005 amp 6000 series servers and NovaScale servers using the ipmilan lanplus or
7. 1 42 WO INGIES StS tetas eat thy e ete sate he t cet a ake sae 1 42 1 9 2 Usage Server using ipmilan lanplus or ipmidrv model 1 42 ETO DSO at et Ne Let Rl hee et att ack tT oil A is Ae ek Bo oe ltt obese 1 44 ELOT NOES e bent a dees Seeded nie ected tea eth sete E ped de ee 1 44 1al O2 NOBUO Gras Bie cei arate oe reins E Bist me ee E ae ep ee sey cle 1 45 1 10 3 Usage bullx blade chassis annann annann ea hos ee AaSG Os 1 47 1 10 4 Usage bullx blade servers scat ok ate lee kateb hel ak ee tee 1 47 1 10 5 Usage Server using ipmidrv model 000 00 c cece eee eens 1 47 Vets Dsii Siti eae cetioniahe atari ta tel teoy sha med wre te sane eh nad keds Pesca ts 1 48 Val Alig Ophio ran aena ie CIR eC eR eR CUA T ees 1 48 Bit Oy AE OS clo ee ee Se ee Nee ee ee See Sere eae Meee ee Leet Se wee ree vere corer 1 48 1122 DsinPDWpOWer cs bons cast cag ec he a ok ea nae wae es 1 53 Klek Notes Pc a a a E A 1 53 Ll 2623 OPNONS drat sa ienei a Hae ee a Wee eee a a ea ae 1 53 TMZ NSS ain ped foc ate ech aceatont ai gic Sirk Ae A Rg TRO tae ON a a eA 1 54 12032 DSIIBOMWER E sleet Sy E oe aiaee eur ew eee ae ee een ee 1 57 klal NOtesiysz ctiaceapecent sacra matted Baits a Ae ae otha Speen fed AEE eld As 1 57 Le Si2 2 ODORS ise eka ace sociema ee hee dak Dean aha wae Aei 1 58 1 13 3 Usage bullx blade chassis ais nca dons netuok a ketene hoger hea aeeas 1 59 1 13 4 Usage bullx blade servers 44s
8. BIOS code This code is not lost when the computer is powered off ESB Ethernet Switch Board ESM Ethernet Switch Module Glossary g 3 F FC LGA Flip Chip Land Grid Array FDB Fan Distribution Board Flash EPROM Flash Erasable Programmable Read Only Memory A type of memory device that is used to store the system firmware code This code can be replaced by an updated code from a floppy disk but is not lost when the computer is powered off FPGA Field Programmable Gate Array FQDN Fully Qualified Domain Name FRU Field Replaceable Unit A component board module fan power supply etc that is replaced or added by Customer Service Engineers as a single entity G GPU Graphical Processing Unit GUI Graphical User Interface H HA High Availability Refers to a system or component that is continuously operational for a desirably long length of time Hardware The physical parts of a system including the keyboard monitor disk drives cables and circuit cards Hardware Partition A set of hardware components that can boot and run a Base OS image Hard Partitioning Ability to split a platform into a number of independent smaller hardware partitions or to merge multiple independent hardware partitions to form a single larger hardware partition HDD Hard Disk Drive HPC High Performance Computing HPC Cluster High Performance Computing Cluster A group of computers linked together to form a single
9. Cpu CPU concerned by the action number all synth default value Command to get a synthesis bsmOSpm sh m linux H 199 184 238 37 u root a getPolicy c synth CPUs 0 to 7 2000000 kHz 68 2560000 kHz 87 userspace or CPUs 0 1 2 4 5 6 7 2000000 kHz 68 2560000 kHz 87 userspace CPUs 3 2560000 kHz 87 2940000 kHz 100 userspace Command to get results for all CPUs bsmOSpm sh m linux H 199 184 238 37 u root a getPolicy c all 2000000 kHz 68 2560000 kHz 87 userspace 2000000 kHz 68 2560000 kHz 87 userspace CPU 0 2000000 kHz 68 2560000 kHz 87 userspace CPU 1 2000000 kHz 68 2560000 kHz 87 userspace CPU 2 2000000 kHz 68 2560000 kHz 87 userspace CPU 3 2000000 kHz 68 2560000 kHz 87 userspace CPU 4 2000000 kHz 68 2560000 kHz 87 userspace CPU 5 2000000 kHz 68 2560000 kHz 87 userspace 6 7 Command to get reults for one CPU bsmOSpm sh m linux H 199 184 238 37 u root a getPolicy c 5 Chapter 1 CLI command for bullx blades 1 49 1 11 2 2 Set the CPU governor and the frequency range The setPolicy action is used to set the CPU governor and to set the frequency range for all CPUs for the usespace governor Syntax bsmOSpm sh h 1l level m model H host u user o outfile I idfile d cfgdir C configfile
10. Firmware hubs and two scalability ports for access to O and coherent memory on other nodes through the FSS SNMP Simple Network Management Protocol SoC System on Chip Socket Central Processing Unit mutlticore interface Glossary g 9 SOL Serial Over LAN Mechanism that enables the input and output of the serial port of a managed system to be redirected via an IPMI session over IP SO DIMM Small Outline Dual In line Memory SR Scratch Register Internal registers of both the Tukwila processor and the O Hub used as scratch area SSD Solid State Drive SSH Secured Shell SSL Secure Socket Layer T TELNET TELecommunication NETwork Protocol used on the Internet or Local Area Networks to provide a bidirectional interactive communications facility Thread A thread or logical processor is the execution context within a single core and the software visibility of multithreading A single multithreaded processor contains two or more threads or logical processors Thresholding An Event filter criterion Thresholding is defined on a Count Time basis aimed at routing significant messages only Identical messages are counted and when the number of messages indicated in the Count field is reached within the period of time indicated in the Time field this message is selected for routing TKW TUKWILA Intel Itanium Processor 4 cores per socket TSM Ten Gigabit Ethernet Switch Module U UCM Ultra Capacitor
11. IPMITOOL configuration parameters e CYPHER_SUITE_ID this parameter specifies the authentication integrity and confidentiality algorithms used when connecting via the lanplus interface The default value is 3 e ME_CHANNEL this parameter specifies the destination channel for IPMI requests The default value is 0x06 e ME_ADDRESS this parameter specifies the IPMB address for ipmi requests The default value is Ox2c The parameters to change are in the bsmcli cfg custom sh tmpl file 1 Rename the file as shown so that it can be called by the BSM CLI scripts cd opt BSMHW bin mv bsmcli cfg custom sh tmpl bsmcli cfg custom sh 2 Edit the bsmcli cfg custom sh file modifying the values you want to change 3 Save the file Preface ix Chapter 1 This chapter describes Hardware Management CLI available for bullx blade systems CLI command for bullx blades bsmBladepower on page 1 2 bsmevent on page 1 6 bsmfru on page 1 7 bsmFWupg on page 1 10 bsmGetConfParam on page 1 15 bsmHWinfocmd on page 1 14 bsmHWpm on page 1 21 bsmidentify on page 1 40 bsminfo on page 1 42 bsmlog on page 1 44 bsmOSpm on page 1 48 bsmPDUpower on page 1 53 bsmpower on page 1 57 bsmreset on page 1 62 bsmsensor on page 1 63 bsmSetConfParam on page 1 66 bsmsol on page 1 67 Chapter 1 CLI command for bullx blades 1 1 1 1 1 2 bsmBladepower bsmBladepower sh is used to perform bullx blades POWER ON OFF operatio
12. Module V VMM Virtual Machine Monitor W WOL Wake On Lan A feature that provides the ability to remotely power on a system through a network connection g 10 bullx B5xx system Hardware Management CLI Reference Guide X XCSI Extended Common System Interface High speed pointto point Bull interface used to interconnect servers XCSI ports are located and managed in the BCS node controller XNC External Node Controller See BCS Y No entries Z No entries Glossary g 11 Bull Cedoc 357 avenue Patton BP 20845 49008 Angers Cedex 01 FRANCE REFERENCE 86 Al 52FG 01
13. by the state default is assert Address of the device generating the event default is the BMC address Cipher suite ID to be used by lanplus interface default is 3 Output file name to which stdout and stderr outputs are redirected Usage Server using ipmilan or lanplus model Syntax bsmevent sh h 1l level a action m model H host u user p password s sensorID b state e eventDir i i2csaAdr Y cipher o outfile Insert events attached to a sensor to the SEL repository The setEvent action is used to insert events attached to a sensor to the SEL repository Command bsmEvent sh m ipmilan H 129 182 6 151 u MWA p guest a setEvent s Rear Fan b ucr Finding sensor Rear Fan ok 0x0000 Pre Init Time stamp Fan 0200 40 Upper Critical going high 590100 bullx B5xx system Hardware Management CLI Reference Guide 1 3 bsmfru bsmfru displays the FRU contents using the standard output When the command is accepted the return code is O If the command fails the return code is 1 The FRU is displayed in stdout as follows lt fru tag gt lt fru content gt 1 3 1 Notes e Servers are identified by their DNS name or IP address H parameter Chapter 1 CLI command for bullx blades 1 7 1 3 2 1 8 Options h level H host D domain m model M hwmanager U user l idfile C configfile d cfgdir p password Y cipher B target
14. getPowerConsumptionHistory Options M generation Model generation For novascale NS4xxF2 model model generation must be F w unit Unit for the result returned Possible values are watt or btuphr Command for a novascale NS4xxF2 power consumption history in Watts bsmHWpm sh m lanplus H 199 182 100 160 u root p bull M F w watt a getPowerConsumptionHistory Power Consumption History Statistic Last Minute Last Hour Last Day Last Week Average Power Consumption Max Power Consumption Min Power Consumption ooo 333 ooo 333 ooo 333 ooo 333 Max Power Time Last Minute Last Hour Last Day Last Week Min Power Time Last Minute Last Hour Tue Apr 06 13 46 58 2010 Tue Apr 06 13 24 33 2010 Mon Apr 05 14 37 09 2010 Sat Apr 03 19 55 13 2010 Tue Apr 06 13 46 58 2010 Tue Apr 06 12 34 19 2010 Last Day Mon Apr 05 13 34 19 2010 Last Week Tue Apr 06 13 46 58 2010 1 36 bullx B5xx system Hardware Management CLI Reference Guide 1 7 3 25 Command for a novascale NS4xxF2 power consumption history in BTU h bsmHWpm sh m lanplus H 199 182 100 160 u root p bull M F w btuphr a getPowerConsumptionHistory Power Consumption History Statistic Last Minute Last Hour Last Day Last Week Average Power Consumption 549755813 BTU hr 549755813 BTU hr 549755813 BTU hr 549755813 BTU hr Max Power Consumption 549755813 BTU hr 2095944040 BTU hr 2095944040 BTU hr 1340029796 BTU hr Min Power Consumpti
15. ipmidrv model for hardware status and BMCinfo information Usage Server using ipmilan lanplus or ipmidrv model Syntax bsminfo sh h i information m ipmilan H host u user p password o outfile l level bsminfo sh h i information m lanplus H host u user p password o outfile l level Y cipher bsminfo sh h i information m ipmidrv o outfile 1l level Notes e Servers are identified by their DNS name or IP address H parameter Options h Displays command usage l Logs in syslog the successful completion of the command OK By default only FAILED completion is logged i information Information type Currently only hardwarestatus and BMCinfo information is available H host DNS name or target server IP address m model Target server model ipmilan lanplus ipmidrv u user BMC user p password User password Y cipher Cipher suite ID to be used by lanplus interface default is 3 o outtile Output file name to which stdout and stderr outputs are redirected te Hardware Component Level e option pron specified hardwarestatus Returns the power status ON OFF of the chassis BMCinfo Returns the BMC IPMI version FW revision Table 1 1 bsminfo options and parameters for NovaScale servers using ipmilan ipmidrv bullx B5xx system Hardware Management CLI Reference Guide 1 9 2 1 Display the chassis power status hardwarestatus is used to display chassis power st
16. m model H host x value u user p password Y cipher o outfile 1 level Options x value on chassis always powers up after AC main electicity is switched on or returns following an interruption off chassis always stays powered off after AC mains electricity is switched on power pushbutton or command required to power on system restore after AC main electricity is switched on or returns power is restored to the state that was in effect when AC main electricity was switched off or lost Command bsmSetConfParam sh m lanplus H 172 31 90 21 u super p pass a setPowerRestorePolicy x on 1 66 bullx B5xx system Hardware Management CLI Reference Guide 1 17 bsmsol The bsmsol command is used to establish a Serial Over Lan session 1 17 1 1 17 2 1 17 3 1 17 3 1 This command is available only for NovaScale servers using the ipmilan or lanplus model Notes e Enter to close the session e Only one Serial Over Lan session can be opened on a given target server e When the target server is a NovaScale 3005 with a BMC firmware including encryption the cipher suite parameter must be set to 3 Options h Displays command usage level Specifies the severity of the messages to be logged in syslog O no message is logged default 1 only the FAILED completion of the command is logged 3 FAILED and successful completion of the command are logged m model Target serve
17. min Power Limit value and less than the max Power Limit value returned by the getNMCapabilities action Command bsmHWpm sh m lanplus H 199 182 100 160 u root p bull a setPowerBudget x 350 Obtain global or individual policy Power Consumption Statistics The getPowerConsumption action is used to get global or per policy Power Consumption Statistics Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a getPowerConsumption i policyID Options i policylD This argument is used to obtain individual policy power consumption statistics Without this argument global power consumption statistics are returned Command bsmHWpm sh m lanplus H 199 182 100 160 u root p bull a getPowerConsumption Current consumption 167 Watts Minimum consumption 135 Watts Maximum consumption 511 Watts Average consumption 203 Watts Chapter 1 CLI command for bullx blades 1 23 1 7 3 4 Get Node Manager and firmware version numbers The getNMVersion action is used to get Node Manager and firmware version numbers Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a getNMVersion Command bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a getNMVersion Node Manager Version Manufacturers ID 0x000157 Intel Node Manager Version supported Node Manager 1 5 IPMI interf
18. notice indicates an action that could cause damage to a program device system or data Preface Vv Related Publications This list is not exhaustive Useful documentation is supplied on the Resource amp Documentation CD s delivered with your system You are strongly advised to refer carefully to this documentation before proceeding to configure use maintain or update your system vi Site Preparation Guide 86 Al 40FA explains how to prepare a Data Processing Center for Bull Systems in compliance with the standards in force This guide is intended for use by all personnel and trade representatives involved in the site preparation process bullx B500 blade system Installation Guide 86 Al 48FB explains how to install and start the system for the first time This guide is intended for use by qualified support personnel bullx B500 blade system Service Guide 86 A7 51FB explains how to service the system This guide is intended for use by qualified support personnel bullx blade system Chassis Hardware Console User s Guide 86 Al 50FB explains how to use the Chassis Hardware Console CHC to manage the system This guide is intended for use by blade system administrators and operators bullx B500 Blade Hardware Console User s Guide 86 Al 49FB explains how to use the bullx B500 compute blades This guide is intended for use by customer administrators and operators bullx B505 Blade Hardware Console User s Guide 86 Al 49FE exp
19. used by the BMC for Alert processing get_pef_list is used to get information about the Platform Event Filter Table used by the BMC for Alert processing When the command is accepted the return code is O If the command fails the return code is 1 Options h Displays command usage level Specifies the severity of the messages to be logged in syslog O no message is logged default 1 only the FAILED completion of the command is logged 3 FAILED and successful completion of the command are logged a param Type of information to be read bmc_info lan_print user_list get_lan_alert_dest get_pef list get_pef_policy H host DNS name or IP address of the target BMC m model Target server model nec ipmilan lanplus tiger u user BMC user name p password BMC user password Authentication key for Express5800 servers Y cipher Cipher suite ID to be used by lanplus interface default is 3 o outtile Output file name to which stdout and stderr outputs are redirected bullx B5xx system Hardware Management CLI Reference Guide 1 6 1 6 1 1 6 2 1 6 3 bsmGetConfParam bsmGetConfParam sh is used to obtain the values of various configuration parameters When the command is accepted the return code is O If the command fails the return code is 1 Notes e This command includes the following actions according to the server bsmGetConfParam a getPowerRestorePolicy bsmGetConfParam
20. 05 10 firmware version of ADM1069_ 3 A 9A 44 06 10 firmware version of ADM1069_ 3 A 9C 44 07 10 firmware version of ADM1069_ 3 A 9E 44 08 10 firmware version of ADM1069_ 3_B 9C 44 03 10 firmware version of ADM1069_3_B 9E 44 04 10 firmware version of ADM1062_4 A 28 20 01 10 firmware version of ADM1062_4 A 2A 20 02 10 BMC Firmware version 11 9 0 Build number 1146 Hardware ID 0x30 Firmware tag Final Edition 20110215 OEM bull Chapter 1 CLI command for bullx blades 1 13 1 5 1 5 1 1 14 bsmHWinfocmd bsmHWinfocmd is used to get various IPMI information such as BMC parameters LAN configuration parameters users list and Alerting parameters bsmHWinfocmd a bmc_info bsmHWinfocmd a lan_print bsmHWinfocmd a user_list bsmHWinfocmd a get_lan_alert_dest bsmHWinfocmd a get_pef policy bsmHWinfocmd a get_pef_list bmc_info is used to get IPMI information such as BMC Firmware revision Manufacturer BMC Device support lan_print is used to get the configuration parameters of the LAN channel used to access the BMC with an OutOfBand connection user_list is used to get information about the users configured for the LAN channel used to access the BMC with an OutOfBand connection get_lan_alert_dest is used to get information about the LAN alert destinations configured for the LAN channel used to access the BMC with an OutOfBand connection get_pef_policy is used to get information about the Alert Policy Table
21. 1 50 98 u ADMIN p ADMIN a getPowerLimit i 0 1 28 bullx B5xx system Hardware Management CLI Reference Guide 1 7 3 11 1 7 3 12 Set the Power Limit to be maintained on a policy ID The setPowerLimit action is used to set the Power Limit to be maintained for a policy ID Syntax bsmHWpm sh h 1l level m model H host u user p password o outfile z ME channel e ME address a setPowerLimit i policyID x powerLimit Options i policylD Policy ID x powerLimit Power Limit to be maintained Command bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a setPowerLimit i 1 x 365 Get the Inlet temperature The getTempTrigger action is used to get the Inlet temperature in Celsius that defines the Policy Trigger Limit for a policy ID Syntax bsmHWpm sh h 1l level m model H host u user p password o outfile z ME channel e ME address a getTempTrigger i policyID Options i policylD Policy ID Command bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a getTempTrigger i 0 Chapter 1 CLI command for bullx blades 1 29 1 7 3 13 Set Inlet temperature The setTempTrigger action is used to set Inlet temperature in Celsius that defines the Policy Trigger Limit for a policy ID Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a setTempTrigger i policyID
22. 1596000 kHz CPU 9 1596000 kHz CPU 10 1596000 kHz CPU 11 1596000 kHz CPU 12 1596000 kHz 54 2927000 kHz 100 8 54 2927000 kHz 100 8 54 2927000 kHz 100 8 CPU 0 1596000 kHz 54 2927000 kHz 100 CPU 1 1596000 kHz 54 2927000 kHz 100 8 CPU 2 1596000 kHz 54 2927000 kHz 100 8 CPU 3 1596000 kHz 54 2927000 kHz 100 8 CPU 4 1596000 kHz 54 2927000 kHz 100 8 CPU 5 1596000 kHz 54 2927000 kHz 100 CPU 6 1596000 kHz 54 2927000 kHz 100 7 8 54 2927000 kHz 100 8 54 2927000 kHz 100 8 54 2927000 kHz 100 8 CPU 14 1596000 kHz CPU 15 1596000 kHz 54 2927000 kHz 100 8 CPU 13 1596000 kHz 54 2927000 kHz 100 54 2927000 kHz 100 1 52 bullx B5xx system Hardware Management CLI Reference Guide 1 12 bsmPDUpower 1 12 1 1 12 2 The bsmPDUpower command is used for monitoring and the administration of Power Distribution Units PDUs This includes obtaining the total power consumption for all the outlets of the PDU and also the warning and critical consumption thresholds and for a PDU poweron poweroff of the PDU outlets and obtaining their status The command uses SNMP get and set requests to the SNMP agent of the PDU bsmPDUpower sh a on off bsmPDUpower sh a status bsmPDUpower sh a getPowerConsumption When the command is accepted the return code is O
23. 2 Chapter 1 CLI command for bullx blades 1 55 1 12 3 3 Get the power consumption The getPowerConsumption action is used to get the power consumption in Watts for all outlets of a PDU Syntax bsmPDUpower sh h 1 level m model H host o outfile a getPowerConsumption p SNMP port S SNMPv C community u user L seclevel A authPass P authPro X privPass x privPro T timeout Options p port SNMP port default value 161 S SNMPv SNMP version 1 default value 2c 3 C community SNMPv1 community default value public for getPowerConsumption action L seclevel SNMPv3 SecurityLevel noAuthNoPriv authNoPriv authPriv u user SNMPv3 user A authPass SNMPv3 authentication passphrase 15 to 32 ASCII characters P authPro SNMPv3 authentication protocol default value MD5 X privPass SNMPv3 privacy passphrase 15 to 32 ASCII characters different than authPass x privPro SNMPv3 privacy protocol default value DES T timeout SNMP timeout default value 30 seconds Command bsmPDUpower sh H 129 182 6 177 a getPowerConsumption m apc Or should be power 10 5000 7000 0 power consumption 10 high power level 5000 critical power level 7000 minimal consumption 0 Output OK Power OK 10 power 10 5000 7000 0 Output WARNING Power WARNING High power level detected 5500 power 5500 5000 7000 0 Output CRITICAL Power CRITICAL Critical po
24. 54 C write_com Display Power Status Command bsmpower sh a status m CMC M 129 184 238 254 Output Example Return Codes O Chassis power is ON 1 Chassis power is OFF Deep Standby Light Standby Command failed Chapter 1 CLI command for bullx blades 1 59 1 13 4 Usage bullx blade servers Notes e The bsmpower sh a status command displays system power ON OFF status System power ON OFF status represents the electrical status and not the functional status of the system For example a system may be powered ON but not RUNNING due to a BIOS initialization error Syntax bsmpower sh h q a action m blade _CMC H host u user p password o outfile 1 level 1 13 41 Power On Command bsmpower sh a on m blade_CMC H 129 184 238 110 u root p pass 1 13 42 Power Off Command bsmpower sh a off m blade_CMC H 129 184 238 110 u root p pass 1 13 43 Display Power Status Command bsmpower sh a status m blade_CMC H 129 184 238 110 u root p pass Output Example Return Codes oO Blade power is ON 1 Blade power is OFF Command failed 1 _ 1 60 bullx B5xx system Hardware Management CLI Reference Guide 1 13 5 Usage Server using ipmidrv model Notes e The bsmpower sh a status command displays system power ON OFF status System power ON OFF status represents the electrical status and not the functional status of the system For example a system may be
25. D pathdir a setPolicy g governor y freq_min x freq max Options g governor cpufreq governor Values available are userspace ondemand performance y freq_min minimum CPU frequency the governor may select only if userspace governor is specified The frequency may be specified in kHz or as a percent of the maximum frequency possible hardware limit x freq_max maximum CPU frequency the governor may select only if userspace governor is specified The frequency may be specified in kHz or as a percent of the maximum frequency possible hardware limit Command to set the CPU frequency governor to ondemand bsmOSpm sh m linux H 199 184 238 37 u root a setPolicy g ondemand OK CPUs 0 to 15 ondemand OK CPUs 0 to 15 2000000 kHz 68 2560000 kHz 87 userspace 1 50 bullx B5xx system Hardware Management CLI Reference Guide 1 11 2 3 1 11 2 4 Get the current frequency of one or all CPUs The getCurrentFreq action is used to get the current frequency of one or all CPUs Syntax bsmOSpm sh h l level m model H host u user o outfile I idfile d cfgdir C configfile D pathdir a getCurrentFreq c c cpu CPU concerned by the action number all synth default value Command to get a synthesis bsmOSpm sh m linux H 199 184 238 37 u root a getCurrentFreq c synth Command to get the frequency of CPU 6 bsmOSpm sh m linux H 199 184 238 37 u r
26. Hardware Management CLI Reference Guide D DES Data Encryption Standard DHCP Dynamic Host Configuration Protocol DMA Direct Memory Access Allows data to be sent directly from a component e g disk drive to the memory on the motherboard The microprocessor does not take part in data transfer enhanced system performance DNS Domain Name Server DSIB DSIBL Dummy System Interface Board The boards designed by Bull when there is not a BCS in the system E EEPROM Electrically Erasable Programmable Read Only Memory A type of memory device that stores password and configuration data EFI Extensible Firmware Interface A specification for a firmware OS interface EFI Shell Simple interactive user interface that allows EFI device drivers to be loaded EFI applications to be launched and operating systems to be booted In addition the EFI Shell provides a set of basic commands used to manage files and the system environment variables See Shell Embedded Management Controller Also known as BMC Baseboard Management Controller This controller embedded on the main system board provides out of band access to platform instrumentation sensors and effectors EMM Embedded Management Module Software embedded in the server module to implement management functions and accessible from the Hardware Console graphical interface EPROM Erasable Programmable Read Only Memory A type of memory device that is used to store the system
27. If the command fails the return code is 1 Notes e Actually only PDUs from APC are supported For APC metered rack PDUs only the getPowerConsumption action is available e The Firmware Revision of APC PDUs must be equal to or higher than v3 Options a action Action h Displays command usage m model PDU model apc H host DNS name or IP address of the PDU level Specifies the severity of the messages to be logged in syslog O no message is logged default 1 only the FAILED completion of the command is logged 3 FAILED and successful completion of the command are logged o outtile Output file name where stdout and stderr outputs are redirected arglist list of arguments specific to the action Chapter 1 CLI command for bullx blades 1 53 1 12 3 1 12 3 1 Usage Syntax bsmPDUpower sh h 1l level m model H host o outfile a action arglist Set on or off one or all outlets of a PDU The on and off actions are used to set on or off one or all outlets for a PDU Syntax bsmPDUpower sh h 1 level m model H host o outfile a on off p SNMP port S SNMPv C community u user L seclevel A authPass P authPro X privPass x privPro c outlet T timeout Options p port SNMP port default value 161 S SNMPv SNMP version 1 default value 2c 3 C community SNMPv1 community default value private pour actions on and off L seclevel S
28. NMPv3 SecurityLevel noAuthNoPriv authNoPriv authPriv u user SNMPv3 user A authPass SNMPv3 authentication passphrase 15 to 32 ASCII characters P authPro SNMPv3 authentication protocol default value MD5 X privPass SNMPv3 privacy passphrase 15 to 32 ASCII characters different than authPass x privPro SNMPv3 privacy protocol default value DES c outlet number or name of one outlet for a PDU default value all all outlets are switched on or off T timeout SNMP timeout default value 30 seconds Command to set all outlets off bsmPDUpower sh H 129 182 6 177 a off m apc S 3 L authPriv u user A authpass P md5 X privpass x des c all Outletl power Off 2 Outlet2 power Off 2 Outlet3 power Off 2 Outlet4 power Off 2 Outlet5 power Off 2 Outlet6 power Off 2 Outlet7 power Off 2 Outlet8 power Off 2 bsmPDUpower sh H 129 182 6 177 a on m apc S 3 L authPriv u user A authpass P md5 X privpass x des c 5 1 54 bullx B5xx system Hardware Management CLI Reference Guide 1 12 3 2 Get the status for one or all outlets of a PDU The status action is used to obtain the status for one or all outlets of a PDU Syntax bsmPDUpower sh h 1l level m model H host o outfile a status p SNMP port S SNMPv C community u user L seclevel A authPass P authPro X privPass x privPro c outlet T timeout O
29. Node Manager Policy Control Syntax bsmHWpm sh h 1l level m model H host u user p password o outfile z ME channel e ME address a endisNMPolicyControl f policyControl i policyID Options f policyControl i policylD Command Policy Control value 0 Global Disable Node Manager policy control 1 Global Enable Node Manager policy control 2 Per Domain Disable Node Manager policies for the specified domain domain 0 3 Per Domain Enable Node Manager policies for the specified domain domain 0 A Per Policy Disable Node Manager policy for the specified policy within domain domain 0 5 Per Policy Enable Node Manager policy for the specified policy within domain domain 0 This argument is mandatory if the policyControl argument is set to 4 or 5 bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a endisNMPolicyControl f 5 i 0 Chapter 1 CLI command for bullx blades 1 25 1 7 3 7 Get the Node Manager policy parameters The getNMPolicy action is used to get the Node Manager policy parameters Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a getNMPolicy i policyID Options i policylD Policy ID Command e To get the Node Manager policy parameters for a lanplus target server model enter bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a getNMPolicy i 0 Node Manager Polic
30. R ON POWERING ON SUSPENDED POWERING DOWN POWER DOWN FAILED TIMEOUT DURING POWER DOWN ON corresponds to server states DOMAIN HALTED POWERED ON LOADING BIOS BIOS READY STARTING EFI BIOS LOADING TIMEOUT RECOVERING BIOS TIMEOUT DURING START EFI RUNNING corresponds to server states EFI STARTED BOOTING OS RUNNING Appendix A Server ON OFF Status Codes A 1 Appendix B User Password Internal Authentication File Appendix B User Password Internal Authentication File B 1 B 1 User Password Authentication Most of the Hardware Management Commands need a user password authentication in order to access a target identified by the PAP manager specified by M hwmanager for NovaScale 5005 amp 6000 Series servers the platform manager specified by H host for NovaScale 4000 Series servers Express 5800 servers and NovaScale servers using the ipmilan model the FTP server site specified by S ftpserver for the bsmpamcmd command or any generic device identified by its IP address The password information used by the Hardware Management Commands may be either specified in the command or extracted from an authentication internal file if no password is specified in the command This internal authentication file contains the list of targets PAP managers platform managers FTP servers or generic devices identified by their role manager FTP server or device and their DNS name or IP address that can be accessed with de
31. _cmd sh a del u devuser D 129 182 3 3 Appendix B User Password Internal Authentication File B 7 B 2 2 5 B 8 Display the contents of the internal authentication file list is used to display the contents of the internal authentication file this means the list of targets that can be accessed with their user password details Syntax bsmcfg_auth_cmd sh a list Command bsmcfg_auth_cmd sh a list lt xml version 1 0 gt lt auth_entries gt lt auth_entry keyname HWMGR_mgr1 password CHdkMQ 3D 3D user usr1 gt lt auth_entry keyname HWMGR_mgr2 password d3h5 user usr2 gt lt auth_entry keyname FTPSRV_srvl password CHdkM0Q 3D 3D user usr1 gt lt auth_entry keyname DEV_ipaddr1 password ZGV2cHdk user devuser gt lt auth_entry keyname HWMGR_ password d3h6 user MWA2 gt lt auth_entries gt bullx B5xx system Hardware Management CLI Reference Guide Glossary This glossary may contain entries that are not relevant to your system A ABR Automatic BIOS Recovery ACPI Advanced Configuration and Power Interface An industry specification for the efficient handling of power consumption in desktop and mobile computers ACPI specifies how a computer s BIOS operating system and peripheral devices communicate with each other about power usage ADM1069 The ADM1069 Super Sequencer is a configurable supervisory sequencing device that offers a s
32. a getMac Output The output is as follows System LOMs NIC Number MAC Address 0 64 9 b8 cf 00 00 1 64 9 b8 d1 00 00 2 64 9 b8 d3 00 00 3 64 9 b8 d5 00 00 Chapter 1 Status Enabled Enabled Enabled Enabled CLI command for bullx blades 1 39 1 8 1 8 1 1 40 bsmidentify The bsmidentify command is used to identify physically a remote host via user visible lights or beeps for a defined interval This command is available for NovaScale servers using the ipmilan lanplus or ipmidrv model and for bullx chassis and blades Options h level m model H host C value B targetname index M hwmanager u user p password Y cipher o ouffile S SNMPv U community P port T timeout Displays command usage Specifies the severity of the messages to be logged in syslog O no message is logged default 1 only the FAILED completion of the command is logged 3 FAILED and successful completion of the command are logged Target server model ipmilan lanplus ipmidrv CMC DNS name or target server IP address Specifies the duration of identification in seconds This value may be set from O to 250 This value set to O stops the identification For bullx chassis and blades this parameter specifies the switching on 1 off O of the LED indicator of the component bullx blade name or bullx chassis component name Possible bullx chassis components are LCPCMM
33. a getTemperatureControlPoint bsmGetConfParam a getPrimaryNTP bsmGetConfParam a getSecondaryNTP Options h level a action m model H host u user p password Y cypher o ouffile Usage Syntax Displays command usage Specifies the severity of the messages to be logged by syslog O no message is logged default 1 only the FAILED completion of the command is logged 3 FAILED and successful completion of the command are logged Action getPowerRestorePolicy getlemperatureControlPoint getPrimaryNTP getSecondaryNTP available according to the server Target server model lanplus ipmilan BMC target IP address BMC user User password Cipher suite ID to be used by lanplus interface default is 3 Output file name to which stdout and stderr outputs are redirected bsmGetConfParam sh h l level a action m model H host u user p password Y cipher o outfile Chapter 1 CLI command for bullx blades 1 15 1 63 1 Get the power restore policy The getPowerRestorePolicy action is used to get the power restore policy On Off or Restore which is applied to the system after an AC power loss Syntax bsmGetConfParam sh h a getPowerRestorePolicy m model H host u user p password Y cipher o outfile 1 level Command bsmGetConfParam sh m lanplus H 172 31 90 21 u super p pass a getPowerRestorePolicy 1 16 bullx B5xx system Hardware Management CLI Ref
34. ace version Patch version binary encoded 0x00 IPMI interface version Major Firmware revision binary encoded 0x01 IPMI interface version Minir Firmware revision BCD encoded 0x04 1 7 3 5 Get Node Manager Capabilities The getNMCapabilities action is used to get Node Manager Capabilities Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a getNMCapabilities g policyTriggerType Options g policyTriggerlype Policy Trigger Type 0 No Policy Trigger 1 Inlet Temperature Policy Trigger Type Command bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a getNMCapabilities g 0 Node Manager Capabilities Manufacturers ID 0x000157 Intel Max Concurrent Settings 10 Max Power Thermal value to be settable as trigger or max Power Limit to be maintained if Policy trigger type is equal to 0 32767 Min Power Thermal value to be settable as trigger or min Power Limit to be maintained if Policy trigger type is equal to 0 1 Min Correction time 6000 ms Max Correction time 600000 ms Min Statistics Reporting Period 1 s Max statistics reporting Period 3600 s Domain limiting scope CPU power limiting IPMI interface version Minir Firmware revision BCD encoded 0x04 1 24 bullx B5xx system Hardware Management CLI Reference Guide 1 7 3 6 Enable Disable Node Manager Policy Control The endisNMPolicyControl action is used to Enable Disable
35. aces ooru E aaa E TE ea vii M delteguiremenis srrerererene piekne e EEE ENEAN ANERE NE EEEREN EEEREN REE viii ipmilan model con det bere sern ian bee a E A ES EE den bel ate E viii lanplus mod l sra itags ii iiai iaa aai Rea e a EE viii ESIC Model uepre rune e E E EE E E A EN E E EEE E viii OG NIE p rcrreriien i iea E a EN aed E A Ae viii blade CMC m del sracsesiiansa teieni ariaa a ia a i Ei viii IPMITOOL Configuration 22 20540 cece bine beat incest bias deet e a E AEA HE ix Chapter 1 CLI command for bullx blades 0c cece cence cence cee en cee eeeeceeee 1 1 1 1 bsmBladepower cetcpeee tee ede cece caret atone peat eaeNetensaceaaels 1 2 Tells Notes piace titi eh init a de at eee eed 1 2 Vole SORIGNE rigas iieii wesc eg htoneic tres ae ek eon E ES 1 3 LLES Usdge ea ey a ee Sn ee ey Se ey ee ee 1 4 1 2 DSMSVERE erneer ern nee E EE AE ANE E AE AAE EN E 1 6 2l OPTIONS eerecirrisi ited reri tesunee oe EEE E EEE a a ea ia 1 6 1 2 2 Usage Server using ipmilan or lanplus model 20 20005 1 6 1 3 DST oroe Ee E E E E E A E EA neater ate aiterd 1 7 kale NOIS saspe rmor aeaa EAEE eae AEN S 1 7 1 3 2 OPHONS ee beet cee biwd sade ster ed aa E EE E eae RGS 1 8 1 3 3 Usage bullx blade chassis s peccccnadnartndornaenrnn keacander ee aes 1 9 1 3 4 Usage bull blade servers sc werd ton ccheamieynagen tes here ieee 1 9 1 3 5 Usage Server using ipmidrv model 0 000 c cece eee 1 9 1 4 Demir VU carn peep onde
36. action H host m model bladelndex S SNMPv C community P port T timeout o outfile Displays command usage Specifies the severity of the messages to be logged in syslog O no message is logged default 1 FAILED completion only is logged 3 FAILED and SUCCESSFUL completion are logged Quiet option stops all outputs stdout sdterr or outfile if o option is specified Action on off soft awake asleep status restart Escala PL servers Action on off off_force status bullx chassis CMC IP address if model is blade CMC Target system model blade_CMC Blade index blade slot SNMP version 1 default value 2 3 SNMP community default value is public for the status action and private for the other actions SNMP port default value is 161 SNMP timeout default value is 20s SSH connection timeout default value is 30s Output file name to which stdout and stderr outputs are redirected Chapter 1 CLI command for bullx blades 1 3 1 1 3 Usage 1 1 3 1 Power On Command bsmBladepower sh a on m blade _CMC H 192 168 200 10 I 7 U community 1 1 3 2 Soft Power Off 1 1 3 3 Power Off Command bsmBladepower sh a off m blade_CMC H 192 168 200 10 I 7 U community 1 1 3 4 Soft Power Awake 1 1 3 5 Power Asleep 1 4 bullx B5xx system Hardware Management CLI Reference Guide 1 1 3 6 Display Power Status The user can check the server blade power
37. adecimal i e 0x01 for temperature or with the sensor type string i e Power Unit e s sensorid and t type parameters for m ipmilan model are exclusive e B bladename and c parameters for m blade model are exclusive Chapter 1 CLI command for bullx blades 1 63 1 15 2 1 64 Options h level y H host m model M hwmanager U user p password Y cipher C B bladename S SNMPv C community P port T timeout o ouffile s sensorid t type Displays command usage Specifies the severity of the messages to be logged in syslog O no message is logged default 1 only the FAILED completion of the command is logged 3 FAILED and successful completion of the command are logged Displays details of each sensor See output section below DNS name or target server IP address CMC IP address for bullx chassis or bullx blade IP address Target server model nec ipmilan lanplus tiger ipmidrv blade CMC blade_CMC NS and EL Blade server manager IP address SMU user on the target server for NovaScale 4000 series BMC user for NovaScale target servers using the ipmilan model bullx chassis bullx blades User password Authentication key for Express5800 servers Cipher suite ID to be used by lanplus interface default is 3 On blade servers used In order to get sensors of the blade chassis only On IPMI servers used in conjunction to v in order to
38. at allows the management of data centers BSM is capable of supporting many different types of servers BT Block Transfer One of the three standardized IPMI System interfaces used by system software for transferring IPMI messages to the BMC A per block handshake is used to transfer data higher performance C Chassis Hardware Console Graphical user interface used to access the management software embedded in the Chassis Management Module CHC See Chassis Hardware Console Clipping An Event filter criterion Clipping is defined on a Count Time basis aimed at routing a pre defined number of messages only Identical messages are counted and when the number of messages indicated in the Count field is reached within the period of time indicated in the Time field no other messages will be selected for routing CMB Chassis Management Board CMC A Corrected Memory Check condition is signaled when hardware corrects a machine check error or when a machine check abort condition is corrected by firmware See MCA CMC Chassis Management Controller CMM Chassis Management Module Core Core is the short name for the processor execution core implemented on a processor A core contains one or more threads logical processors CRU Customer Replaceable Unit A component board module fan power supply etc that is replaced or added by the End User as a single entity CSE Customer Service Engineer g 2 bullx B5xx system
39. atus info Notes e e option is ignored for the ipmilan model e H host and D domain parameters are not used ignored if present Command bsminfo sh i hardwarestatus m ipmilan H nsmaster u MWA p guest Output Command bsminfo sh i hardwarestatus m lanplus H nsmaster u MWA p guest Output 1 9 2 2 Display BMC information BMCinfo is used to display BMC information such as IPMI version firmware revision etc Command bsminfo sh i BMCinfo m ipmilan H 129 182 6 50 u MWA p guest Device ID i Device Revision Firmware Revision 3 26 IPMI Version Manufacturer ID Command bsminfo sh i BMCinfo m lanplus H 129 182 6 50 u MWA p guest Output Device ID Device Revision Firmware Revision 3 26 IPMI Version 7 Manufacturer ID Chapter 1 CLI command for bullx blades 1 43 1 10 bsmlog bsmlog is used to direct system log contents SEL to the standard output When the command is accepted the return code is O If the command fails the return code is 1 If v option is not specified the output format is lt rank gt lt record id gt lt local date gt lt local time gt lt event target gt lt severity gt lt event description gt If v option is specified one record is displayed by field on several rows according to the format lt label gt lt value gt 1 10 1 Notes e Servers are identified by their DNS name or IP address H parameter e n rang
40. bullx B5xx system Hardware Management CLI Reference Guide O O O O x REFERENCE 86 Al 52FG 01 bullx B5xx system Hardware Management CLI Reference Guide Hardware June 2011 BP 20845 49008 Angers Cedex 01 FRANCE REFERENCE 86 Al 52FG 01 The following copyright notice protects this book under Copyright laws which prohibit such actions as but not limited to copying distributing modifying and making derivative works Copyright Bull SAS 2011 Printed in France Trademarks and Acknowledgements We acknowledge the right of proprietors of trademarks mentioned in this manual All brand names and software and hardware product names are subject to trademark and or patent protection Quoting of brand and product names is for information purposes only and does not represent trademark misuse The information in this document is subject to change without notice Bull will not be liable for errors contained herein or for incidental or consequential damages in connection with the use of this material Table of Contents Prefab eo iiecheciy anew pane aue ener shite pee eae cin bold E bead aubene tue bealed v Intended Readers seripereertane ene Ee AE E AEN E E E E Highlighting amp acu tein dbo nkun nre e ate A E S E EE E EA tes v Related Publications serieriniiiaeeiaio taiete ike ad bike ede EE E yi Iniroduchion soserene eee ran A E A A E E vii Password specification sis errre ri loot
41. chassis and bullx blades Syntax bsmlog sh h v m CMC H host u user p password n range c o outfile 1 level Command to display the most recent SELs bsmlog sh n 2 m CMC H 129 184 238 254 u root p pass 2 0x011d 05 13 2009 17 35 55 0x80 Temperature IBSW_TEMP1 2000 06 Lower Non critical going low 501414 Deasserted 1 0x011c 05 13 2009 17 35 22 0x80 Temperature IBSW_TEMP1 2000 06 Lower Non critical going low 501314 Reading 19 lt Threshold 20 degrees C Usage bullx blade servers bsmlog is also used to clear the system log contents SEL on NovaScale and Evolutive Line Blade servers NovaScale servers using the ipmilan or ipmidrv model bullx chassis and bullx blades Syntax bsmlog sh h v m blade_CMC H host u user p password c n range o outfile 1 level Command TBC Usage Server using ipmidrv model bsmlog is also used to clear the system log contents SEL on NovaScale and Evolutive Line Blade servers NovaScale servers using the ipmilan or ipmidrv model bullx chassis and bullx blades Syntax bsmlog sh h v m ipmidrv n range o outfile 1l level c Chapter 1 CLI command for bullx blades 1 47 1 11 bsmOSpm The bsmOSpm command is used to control the CPU policy and frequency of platform via 1 11 1 1 11 2 1 48 cpufrequtils package When the command is accepted the return code is O If the com
42. computer Host Operating System The Operating System that is booted at initialization and that is a Virtual Machine Monitor VMM and a number of guest OS Hot Plugging The operation of adding a component without interrupting system activity g 4 bullx B5xx system Hardware Management CLI Reference Guide Hot Swapping The operation of removing and replacing a faulty component without interrupting system activity HT HyperThreading See Multi Threading 12C Intra Integrated Circuit The 12C Inter IC bus is a bi directional two wire serial bus that provides a communication link between integrated circuits ICs The I2C bus supports 7 bit and 10 bit address space devices and devices that operate under different voltages IB InfiniBand iBMC Integrated Baseboard Management Controller See Embedded Management Controller iCare The iCare Console insight Care is a web based administration application which provides tools for hardware unit maintenance ICH Input Output Hub Provides a connection point between various O components and Intel processors ICMB Intelligent Chassis Management Bus Name for the architecture specifications and protocols used to interconnect intelligent chassis via an RS 485 based serial bus for the purpose of platform management ILB ILBL I O Legacy Boards The Bull designed I O boards for the MESCA modules INCA INtegrated Cluster Architecture IOH Input Output Hub An Intel QPI agent tha
43. ddress a setMaxAllowedCPUTState s stateNumber Options s state Number T State number to be set from O to n 1 where n is the Number of T States returned with the getNumberOfCPUStates action available on the platform Command bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a setMaxAllowedCPUTState s 3 Get the maximum power the minimum power and the power budget cap The getPowerBudget action is used to get the maximum power the minimum power and the power budget cap in Watts or BTU h Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile M generation w unit a getPowerBudget Options M generation Model generation For novascale NS4xxF2 model model generation must be F w unit Unit in which is expressed the returned result Possible values are watt or btuphr Command for a Novascale NS4xxF2 result in Watt bsmHWpm sh m lanplus H 199 182 100 160 u root p bull a getPowerBudget M F w watt Maximum power 506 Watt Minimum power 139 Watt Power cap 506 Watt Command for a Novascale NS4xxF2 result in BTU hr bsmHWpm sh m lanplus H 199 182 100 160 u root p bull a getPowerBudget M F w btuphr Maximum power 2027224563 BTU hr Minimum power 309237645 BTU hr Power cap 2027224563 BTU hr Chapter 1 CLI command for bullx blades 1 33 1 7 3 22 Set the power budget cap The setPowerBudget action is used to set the power bud
44. dicated users passwords This file is created and managed using the bsmcfg_auth_cmd command The bsmcfg_auth_cmd command allows to e add an entry defined by user password target e delete an entry defined by user target e get the encoded password for an entry defined by user target e get the decoded password for an entry defined by user target e ist the entries The password information is stored in the authentication internal file as a base64 encoded string B 2 bullx B5xx system Hardware Management CLI Reference Guide B 2 B 2 1 B 2 2 bsmcfg_auth_cmd command bsmcfg_auth_cmd command manages the internal authentication file bsmcfg_auth_cmd sh bsmcfg_auth_cmd sh bsmcfg_auth_cmd sh bsmcfg_auth_cmd sh bsmcfg_auth_cmd sh Syntax bsmcfg_auth_cmd sh a add a getE a getD a del a list h a action M manager H manager S ftpserver D ipaddr u user p password When the command is accepted the return code is O If the command fails the return code is 1 Notes e M manager H manager D ipaddr and S ftpserver parameters are exclusive e For NovaScale servers using the ipmilan model it is possible to use the same user password authentication for all the servers available This can be done by setting un Options h a action M manager H manager S ftpserver D ipaddr u user p password as the manager parameter Displays command usage Ac
45. e ec cece cece eee eeeee B 1 B 1 User Password Authentication 0 0c ccc cence eect e eens B 2 B 2 bsmcfg_auth_cmd command s an annann neonne Cade ka abuse ees hae Abus B 3 B21 Notes eacvepaa aad VS eee is ya ei B 3 Be2e2 Options eA s eeeere gaa cece eet he nected tee Pant a edd yeah sete A E B 3 Glossary 5s csc sds oe LA a ec aero eS Crea ode DNS hae eee eed ened dead g 1 iv bullx B5xx system Hardware Management CLI Reference Guide Preface This guide describes the Hardware Management CLI Command Line Interface for bullx blade systems Note The Bull Support Web site may be consulted for product information documentation updates and service offers http support bull com Intended Readers This guide is intended for System Administrators and Operators in charge of managing systems locally and remotely and of writing server management batch scripts Highlighting The following highlighting conventions are used in this guide Bold Identifies the following e Interface objects such as menu names labels buttons and icons e File directory and path names e Keywords to which particular attention must be paid Italics Identifies references such as manuals or URLs monospace Identifies portions of program codes command lines or messages displayed in command windows lt gt Identifies parameters to be supplied by the user Commands entered by the user A WARNING A Warning
46. e is ignored if the c option is specified e By default the n range parameter is set to n 10 1 44 bullx B5xx system Hardware Management CLI Reference Guide 1 10 2 Options h level V n range e element H host m model M hwmanager U user I idfile C configfile d cfgdir t event_type p password Y cipher B targetname S SNMPv C community P port Displays command usage Specifies the severity of the messages to be logged in syslog O no message is logged default 1 only the FAILED completion of the command is logged 3 FAILED and successful completion of the command are logged Displays record details See below Range of records to be displayed May be specified as a number or as an interval n n displays the n most recent records n rl r2 displays records from r1 to r2 Events are displayed in chronological order beginning with the most recent ones Hardware element concerned in PAM PUID format DNS name or target server IP address CMC IP address for bullx chassis or bullx blade IP address Target server model fame nec ipmilan lanplus tiger ipmidrv blade HMC CMC blade_CMC DNS name or PAP Manager IP address NovaScale 5005 amp 6000 series or NS and EL Blade servers manager IP address or HMC IP address for PL servers PAP administrator for NovaScale 5005 amp 6000 series SMU user on the target server for NovaScale 4000 series
47. erence Guide 1 6 4 1 64 1 1 6 4 2 Usage Server using ipmilan or lanplus model Syntax bsmHWinfocmd sh h m ipmilan H host a param u user p password o outfile 1l level bsmHWinfocmd sh h m lanplus H host a param u user p password o outfile 1l level Y cipher Get IPMI information for a server using ipmilan Command bsmHWinfocmd sh a bmc_info m ipmilan H 129 182 6 151 u MWA p guest Device ID 34 Device revision Sel Firmware revision 0 18 IPMI version 2 0 Manufacturer name NEC Additionnal Device Support Sensor Device SDR Repository Device SEL Device FRU Inventory Device Get IPMI information for a server using lanplus Command bsmHWinfocmd sh a bmc_info m lanplus H 129 182 6 151 u MWA p guest Device ID 34 Device revision aoe Chapter 1 CLI command for bullx blades 1 17 1 643 1 644 1 18 Get configuration parameters of the LAN channel Command bsmHWinfocmd sh a lan_print m ipmilan H 129 182 6 151 u MWA p guest Set in Progress Set Complete Auth Type Support NONE MD2 MD5 PASSWORD Auth Type Enable Bo areleve IP Address Source Static Address IP Address 129 182 6 151 Subnet Mask 255 255 255 0 MAC Address 00 12 34 56 78 90 SNMP Community String public IP Header See BMC ARP Control So pilates Get information about users configured for the LAN channel Command bsmHWinfocmd sh a user_list m
48. generation For novascale NS4xxF2 model model generation must be F w unit Unit in which is expressed the returned result Possible values are watt or btuphr Command for a novascale NS4xxF2 power consumption value in Watts bsmHWpm sh m lanplus H 199 182 100 160 u root p bull M F w watt a getPowerConsumption Power consumption information System Board System Level Reading 140 W Warning threshold 917 W Failure threshold 966 W Amperage value 0 6 A Headroom Statistic Reading System Instantaneous Headroom 1264 W System Peak Headroom 1230 W Command for a novascale NS4xxF2 power consumption value in BTU h bsmHWpm sh m lanplus H 199 182 100 160 u root p bull M F w btuphr a getPowerConsumption Power consumption information System Board System Level Reading 477 BTU hr Warning threshold 3129 BTU hr Failure threshold 3296 BTU hr Amperage value 0 6 A Headroom Statistic Reading System Instantaneous Headroom 824633721 BTU hr System Peak Headroom 1889785610 BTU hr Chapter 1 CLI command for bullx blades 1 35 1 7 3 24 Get get the average and the peak power consumption history The getPowerConsumptionHistory action is used to get the average and the peak power consumption history in watts or BTU hr for the last minute last hour last day and the last week Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile M generation w unit a
49. ger Statistics Manufacturers ID 0x000157 Intel Current 683 Minimum 620 Maximum 752 Average 682 Timestamp 1285366705 Statistics Reporting Period 1 s domain Id 0 Measurement state Measurements in progress host CPU in SO state Reset the Node Manager Power Statistics The resetNMStatistics action is used to reset the Node Manager Power Statistics Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a resetNMStatistics O mode i policyID Options O mode Specifies the type of statistics to be reset O global statistics including power statistics and inlet temperature statistics 1 per policy statistics including power and trigger statistics i policylD This argument is mandatory only if mode argument is set to 1 Command e To reset the global Node Manager Power Statistics for a lanplus target server model enter bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a resetNMStatistics O 0 Chapter 1 CLI command for bullx blades 1 31 1 7 3 17 1 7 3 18 1 7 3 19 Get the number of P States and T States available on the target platform The getNumberOfCPUStates action is used to get the number of P States and T States available on the target platform Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a getNumberOfCPUStates Command bsmHWpm
50. get sensors information in a more compact form Blade name For Blade servers only SNMP version 1 default value 2 3 For Blade servers only SNMP community default value is public For Blade servers only SNMP port default value is 161 For Blade servers only SNMP timeout default value is 20 For Blade servers only Output file name to which stdout and stderr outputs are redirected un Specify a list of sensor s specified between quotes and separated by comma s to be read Process only sensors of the specified type as defined in IPMI specification Process only analog sensors of the type specified with type bullx B5xx system Hardware Management CLI Reference Guide 1 15 3 1 15 3 1 1 15 4 1 15 5 Usage bullx blade chassis Syntax bsmsensor sh h v m CMC H host u user p password o outfile l level s sensorid_list t type a c Display sensors Command bsmsensor sh m CMC H 129 184 238 254 u root p pass 0x00200001 CMB Temp 0x20 31 000 degrees C ok 0 000 10 000 20 000 40 000 50 000 60 000 0x00200006 IBSW_Templ 0x20 22 000 degrees C ok 0 000 10 000 20 000 40 000 50 000 60 000 0x00200009 FAN2A 0x20 12500 000 RPM ok 3200 000 6900 000 8000 000 17800 000 18400 000 19000 000 Usage bullx blade servers Syntax bsmsensor sh h v m blade CMC H host u user p pass
51. get cap in Watts BTU hr or as a percentage Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile M generation w unit a setPowerBudget x valu Options M generation Model generation For novascale NS4xxF2 model model generation must be F w unit Unit for the result returned Possible values are watt btuphr or percent x value Total Power Budget to be set This value must be greater than the min Power Limit value and less than the max Power Limit value returned with the getNMCapibilities action Command for a novascale NS4xxF2 result in Watts bsmHWpm sh m lanplus H 199 182 100 160 u root p bull a setPowerBudget x 350 M F w watt Command for a novascale NS4xxF2 result in BTU hr bsmHWpm sh m lanplus H 199 182 100 160 u root p bull a setPowerBudget x 350 M F w btuphr 1 34 bullx B5xx system Hardware Management CLI Reference Guide 1 7 3 23 Get warning threshold failure threshold system instantaneous headroom system peak headroom and instantaneous power consumption The getPowerConsumption action is used to get warning threshold failure threshold system instantaneous headroom and system peak headroom in watts or BTU h and also instantaneous power consumption in Ampere Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile M generation w unit a getPowerConsumption Options M generation Model
52. iet sity Oks de eevee WI 1 60 1 13 5 Usage Server using ipmidry model 2 5 2ccnspaycrscie estas dees 1 61 1A P SITESER Fee NS dac ae adres T rc aod Stee late ee Oe OR 1 62 Tad Adis NOIES faz ccdh a Saaresded iaaa OH SA AAR ID ATS IORI A 1 62 TTA 2 QORUONS niece carer OE etki Tak Baebes AFR RETA QA wee 1 62 1 14 3 Usage bullx blade servers css cy atone ca tuakodnvedeese aeduee ewes 1 62 PU nDSMSeMSOn ee ty tte thik cee Reet ted a RE de ee able 1 63 KISAT SC ge a 1 63 oie a OPON eae Ree Ste are Te eR es Ste ew ey a ee Nera Stee e ee iene 1 64 1 15 3 Usage bullx blade chassis t ccieMide tier ide Seat 1 65 1 15 4 Usage bullx blade servers 55505 hy bk bee Gh eet ky 1 65 1 15 5 Usage Server using ipmidrv model 0 0 00 cece eee eee ee 1 65 Ils bsmseiConi Params ar ote lere eth k eke ta ha thacne pee ee ae es 1 66 Tel OF Vic OP HONS esirin Seed Sot aR pantie a adil pech a oped Rich ane BR pelh 1 66 TAG 2 Usage paar aere a esac bal pachake area e E eee aphate an wen 1 66 NETH aS RSE atid Ge E ob eo ede ence Pe ea ee oe Eee 1 67 Vadose NOIES aise soe toca cacti eo ae eee toca en chase ego eh a crete de AS 1 67 Teel 723 OPON sien a ade BG te aod Dole eats aad ete Pn 1 67 al Pde HWSAGGra a Rake htt tea el teat ch oad tee ahi a a a e tere bathe cede tt 1 67 Appendix A Server ON OFF Status Codes 2c cece ccc eee e eect cee eeceeeeeees A 1 Appendix B User Password Internal Authentication Fil
53. ile to be used when activating a partition This argument is required unless the managed system is in the manufacturing default configuration User password or authentication key Managed system name SNMP version 1 default value 2 3 SNMP community default value is public for the status action and private for the on and off actions SNMP port default value is 161 SNMP timeout default value is 20s SSH connection timeout default value is 30s Output file name to which stdout and stderr outputs are redirected bullx B5xx system Hardware Management CLI Reference Guide 1 13 3 1 13 3 1 1 13 3 2 1 13 3 3 Usage bullx blade chassis Notes e In order to power on off a chassis the system executing bsmpower must be declared on the target server as a member of a SNMPv1 read write community The default read write community name used by bsmpower is private The bsmpower sh a status command displays system power ON OFF status System power ON OFF status represents the electrical status and not the functional status of the system For example a system may be powered ON but not RUNNING due to a BIOS initialization error Syntax bsmpower sh h q a action m CMC M hwmanager S SNMPv C community P port T timeout o outfile 1l level Power On Command bsmpower sh a on m CMC M 129 184 238 254 C write_com Power Off Command bsmpower sh a off m CMC M 129 184 238 2
54. ingle chip solution for supply monitoring and sequencing in multiple supply systems ARU Add Removeable Unit A hardware logical unit or a group of logical units that can be viewed handled by an Operating System or the BIOS or the Platform Management Software An ARU can be nested and is not necessarily separable from other ARUs An ARU is also known as a PMU ASR Automatic Server Restart ASIC Application Specific Integrated Circuit B Base Operating System The Operating System that is booted at initialization BCE Elementary calculation block BCEA ASIC elementary calculation block BCEF FPGA elementary calculation block BCS Bull Coherent Switch This is the Bull eXternal Node Controller providing SMP upgradeability up to 16 processors The BCS ensures global memory and cache coherence with optimized traffic and latencies in both IPF preferred and XPF preferred variants BHC See Blade Hardware Console BIOS Basic Input Output System A program stored in flash EPROM or ROM that controls the system startup process BIST Built In Self Test See POST Blade Hardware Console Graphical user interface used to access the management software embedded in the blade module Glossary g 1 BMC Baseboard Management Controller See Embedded Management Controller BOOTP Network protocol used by a network client to obtain an IP address from a configuration server BSM Bull System Manager A software package th
55. ipmilan H 129 182 6 151 u MWA p guest Channel Number 0x7 Maximum User Ids 4 Enabled User IDs 3 User ID 1 User name Fixed Name Yes Access Available call in callback Link Authentication enabled IPMI Messaging enabled Privilege Level ADMINISTRATOR User ID 2 User name MWA Fixed Name No Access Available call in callback Link Authentication enabled IPMI Messaging enabled Privilege Level ADMINISTRATOR bullx B5xx system Hardware Management CLI Reference Guide 1 645 Get information about LAN alert destinations for the LAN channel Command bsmHWinfocmd sh a get_lan_alert_dest m ipmilan H 129 182 6 151 u MWA p guest Alert Destination 0 Alert Acknowledge Unacknowledged Destination type PET Trap Retry Interval 0 Number of Retries 0 Alert Gateway Default Alert IP Address 0 0 0 0 Alert MAC Address 00 00 00 00 00 00 Alert Destination 1 Alert Acknowledge Unacknowledged Destination type PET Trap Retry Interval 25 Number of Retries 3 Alert Gateway Default Alert IP Address 129 182 6 22 Alert MAC Address 00 11 22 33 44 55 1 6 4 6 Get information about the Alert Policy Table Command bsmHWinfocmd sh a get_pef_policy m ipmilan H 129 182 6 151 u MWA p guest Alert policy table entry 1 Policy set zL Policy entry rule Try next entry Channel number 7 Channel medium 802 3 LAN Destination number 2 Alert destination type
56. is Management Module for NS Blade servers EL Blade servers bullx B series e SNMP requests to the SNMP agent of Power Distribution Units PDU e SSH connection to Harware Management Console HMC for Escala PL servers Escala PL servers remote management with HMC requires identity key files to be installed on the HMC the presence of a SSH client configuration file to perform non prompt ssh connection to the HMC locally key files and configuration file if any must be in the same directory Most of the commands may also use an InBand connection for local Hardware Management of NovaScale servers running Linux and managed via IPMI using the ipmidrv model Most of the commands may also use authentication file This is why the following packages have to be installed e perl XML LibXML e perl XML LibXML Common e perl XML SAX e perl XML NamespaceSupport There are installed in the the bin subdirectory of the BBMHW package install directory Default opt BSMHW bin Password specification All password arguments may be either specified by p password or extracted from the internal authentication file This file is created with the bsmcfg_auth_cmd sh command detailed in Appendix B Preface vii Model requirements The Hardware Management CLI is designed for range of server types as listed previously The protocol used to connect the target hosts is given via m model parameter Although very similar the some mode
57. lains how to use the bullx B505 accelerator blades This guide is intended for use by customer administrators and operators bullx B510 Blade Hardware Console User s Guide 86 Al 49FG explains how to use the bullx B510 dual nodes blades This guide is intended for use by customer administrators and operators Resource and Documentation CD contains the tools and documentation required to configure operate and maintain the equipment bullx B5xx system Hardware Management CLI Reference Guide Introduction The Hardware Management CLI provides an easy Command Line Interface CLI for local or remote hardware management and automation scripts It is designed for e NovaScale 3005 4000 5005 amp 9006 series NS R400 series NS T800 series Express 5800 servers bullx S series bullx B series bullx R series Blade servers and Escala Privilege Line servers e A32 or IA64 architectures e Linux systems ONLY The Hardware Management CLI uses both Out of Band and In Band connections to the target hosts The OutOf Band network protocols used for these connections are dependant on server type and are based on IPMloverLAN SNMP web services or SSH associated with identity key files for silent commands for examples e IPMloverLAN for NovaScale R400 amp T800 series ns bullion series bullx series and all servers using the ipmilan or lanplus model e PAM Web services for NovaScale 5005 amp 6000 series e SNMP requests to the Chass
58. ls have some mandatory arguments ipmilan model e Model used for Cool Cabinet Door and novascale server using IMPI e The user and password arguments are NOT mandatory e If p password IS NOT specified and u user IS specified the internal authentication file is searched for the password which may be there lanplus model e Model used for Cool Cabinet Door and the novascale server that uses IPMI e The user argument is mandatory e If p password is not specified the internal authentication file is searched for the password which may be there e IPMI connection is established with the lanplus interface using cipher suite IDs for authentication integrity and encryption algorithms The default cipher suite ID is 3 and specifies the RAKP HMAC SHA1 authentication HMAC SHA1 96 integrity and AES CBC 128 encryption algorithms ipmidrv model e Model used for the server with the ipmidrv driver e IPMI management of a local system requires the installation and configuration of the Linux OpenlPMI driver and the installation of the OpenIPMI library e The user password and host arguments MUST NOT be specified for local hardware management via IPMI CMC model e Model used for bullx chassis e None specific arguments blade_CMC model e Model used for bullx blade servers e None specific arguments viii bullx B5xx system Hardware Management CLI Reference Guide IPMITOOL Configuration It is possible to change some
59. mHWpm sh bsmHWpm sh a getPowerConsumption getNMVersion getNMCapabilities endisNMPolicyControl getNMPolicy setNMPolicy removeNMPolicy getPowerLimit setPowerLimit getTempTrigger setTempTrigger setNMPowerDrawRange getNMStatistics resetNMStatistics getNumberOfCPUStates getMaxAllowedCPUStates setMaxAllowedCPUPState setMaxAllowedCPUTState getPowerBudget M F setPowerBudget M F getPowerConsumption M F getPowerConsumptionHistory M F enablePower M F disablePower M F getLan M F getActiveLan M F When the command is accepted the return code is O If the command fails the return code is 1 Notes e This command only applies to servers that use the ipmilan or lanplus Model e For NovaScale servers whose name ends with an Fx the model generation argument is mandatory Chapter 1 CLI command for bullx blades 1 2 1 7 2 Options a action Action h Displays command usage m model Target server model lanplus ipmilan H host BMC target IP address level Specifies the severity of the messages to be logged in syslog O no message is logged default 1 only the FAILED completion of the command is logged 3 FAILED and successful completion of the command are logged u user BMC user p password User password Y cipher Cipher suite ID to be used by the lanplus interface default is 3 o outtile Output file name where stdout and stderr outpu
60. mand fails the return code is 1 Options a action h m model H host level u user C configfile l idfile d cfgdir D pathdir o outfile arglist Usage Syntax bsmOSpm sh h Action Displays command usage Remote host OS linux Remote target name or IP address Specifies the severity of the messages to be logged in syslog O no message is logged default 1 only the FAILED completion of the command is logged 3 FAILED and successful completion of the command are logged Username for remote connection via ssh Config file used for remote connection default is Identity file used for remote connection default is id_dsa Full path directory containing config file and_identity file Full path directory containing script bsnOSpm_local on remote host Output file name where stdout and stderr outputs are redirected List of arguments specific to the action l level m model H host u user o outfile I idfile d cfgdir C configfile D pathdir a action arglist bullx B5xx system Hardware Management CLI Reference Guide 1 11 2 1 Get the governor and the frequency range of one or all CPUs The getPolicy action is used to get the governor and the frequency range for one or all CPUs Syntax bsmOSpm sh h l level m model H host u user o outfile I idfile d cfgdir C configfile D pathdir a getPolicy c CPU Options c
61. ment that does not go through the OS or other software running on the main processors of the managed system OPMA Open Platform Management Architecture P PCI Peripheral Component Interconnect Bus architecture supporting high performance peripherals PCle PCI Express Latest standard in PCI expansion cards PDB Power Distribution Board Sub assembly of the Power Supply Module PDU Power Distribution Unit Power bus used for the connection of peripheral system components Platform Event A platform event is an event that originates directly from platform firmware BIOS or platform hardware independently of the state of the Operating System or System Mangement Hardware PEF Platform Event Filtering A feature in IPMI that enables the BMC to generate a selectable action e g power on off reset send Alert etc when a configurable event occurs on the management system PET The Platform Event Trap format is used for sending a platform event in an SNMP Trap See Platform Event Glossary g 7 PIROM The Processor Information ROM contains information about the specific processor in which it resides This information includes robust addressing headers to allow for flexible programming and forward compatibility core and L2 cache electrical specifications processor part and S spec numbers and a 64 bit processor number PMU Physically Manageable Unit A hardware logical unit or a group of logical units that can be viewed ha
62. n of the component bulloemupg upgrade the firmware of the component bulloemlisthw display the list of components which can be upgraded presently limited to module 0 Component name M module_id Module ID from O to 3 m model Target server model ipmilan lanplus ipmidrv If not present kcs driver will be used u user Administration login for the Remote Management Module p password Administration password for the Remote Management Module o outtile Output file name to which stdout and stderr outputs are redirected bullx B5xx system Hardware Management CLI Reference Guide 1 4 3 Usage NovaScale servers updated via kiratool Syntax bsmFWupg sh h t kiratool H host F fw_binfile u user p password D tooldir d fw_bindir o outfile Command to upgrade the firmware bsmFWupg sh t kiratool H 129 182 6 110 u super p pass F fw wub MESCB_010100_0026 bin Starting Firmware Upgrade Uploading Firmware File 09 SSeS S545 5554555 90 SSSSaSs S S555 5 100 kkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk Upload complete Flashing Firmware takes about lmin Successfully upgraded firmware Chapter 1 CLI command for bullx blades 1 11 1 4 4 Usage Bull servers updated via ipmitool bulloem extension Syntax bsmFWupg sh h t ipmitool H host F fw_binfile u user p password a action E component M module m model d fw_bindir o outfile 1 44 1 Display
63. name S SNMPv C community P port T timeout o ouffile e ALL Displays command usage Specifies the severity of the messages to be logged in syslog O no message is logged default 1 only the FAILED completion of the command is logged 3 FAILED and successful completion of the command are logged DNS name or target server IP address CMC IP address for bullx chassis or bullx blade IP address Target server domain name NovaScale 5005 amp 6000 series only Target server model fame nec ipmilan lanplus tiger ipmidrv blade HMC CMC blade_CMC DNS name or PAP Manager IP address NovaScale 5005 or 6000 series or NS and EL Blade server manager IP address or HMC IP address for PL servers PAP administrator for NovaScale 5005 or 6000 series SMU user on the target server for NovaScale 4000 series BMC user for NovaScale target servers using the ipmilan model bullx chassis bullx blades User for ssh connection to the HMC for PL servers Identity key file used to perform connection to the HMC with ssh ssh client configuration file used to perform non prompt connection to the HMC Directory where identity key file and ssh client configuration file are installed default value is etc ssh User password Authentication key for Express5800 servers Cipher suite ID to be used by lanplus interface default is 3 Blade name for Blade servers or managed system name CECname for PL servers
64. nce of two or more processors on a single chip Multi Threading The ability of a single processor core to provide software visibility similar to that of several cores and execute several threads in apparent to software simultaneity while using limited additional hardware resources with respect to a core without multithreading Depending on core design the instructions issued for execution by the core at a given cycle may be either Hyper Threading HT from a single thread switching to another thread upon occurrence of specific events e g cache misses or Simultaneous Multi Threading SMT from both threads MXB MXBC Memory and Xeon Board Memory and Xeon Board Controller g 6 bullx B5xx system Hardware Management CLI Reference Guide N Nehalem NEHALEM Intel Xeon Processor 8 cores per die NFS Network File System NIC Network Interface Controller NUMA Non Uniform Memory Access NVRAM Non Volatile Random Access Memory Off Lining See On lining OffLining On Lining Off Lining On lining and off lining are dynamic logical operations On lining is the non physical addition of an ARU to the running OS The on lined unit already exists in the configuration as an inactive unit present and connected Offlining is the non physical removal of an ARU from the running OS The off lined unit remains in the configuration as an inactive unit ready to be on lined OOB Out Of Band Access to system platform manage
65. ndled by an Operating System or the BIOS or the Platform Management Software A PMU can be nested and is not necessarily separable from other PMUs A PMU is also known as an ARU POST Power On Self Test Processor Each processor contains one or more dies in a single package Each die contains one or more cores Each core contains one or more threads logical processors Each processor is housed in a processor socket PSMI Power Supply Management Interface PSU Power Supply Unit Sub assembly of the Power Supply Module PSWB PCI SWitch Board PSWM PCI SWitch Module PWM Pulse Width Modulation Q QDR Quad Data Rate Communication signalling technique where data is transmitted at four points in the clock cycle QPI Quick Path Interconnect High speed point to point Intel interface used to interconnect processors and O Hubs and optionally node controllers BCS QSB Quad Switch Board QSFP Quad Small Form factor Pluggable Low power interconnect technology QSMB Quad Switch Module InfiniBand Switch R RADIUS Remote Authentication Dial In User Service RAS Reliability Availability Serviceability RMIl Reduced Media Independent Interface A standard that reduceds the number of signals pins required to connect an Ethernet chip to physical layer transceiver See MII g 8 bullx B5xx system Hardware Management CLI Reference Guide RTC Real Time Clock S SAS Serial Attached SCSI A data tran
66. ns and to check the power state by using the Chassis Controller Manager sh a bsmBladepower bsmBladepower bsmBladepower bsmBladepower bsmBladepower bsmBladepower sh sh sh sh sh a a a 4 a on off soft awake asleep status This command is asynchronous and returns the prompt before the end of command completion When the command is accepted the return code is O If the command fails the return code is 1 A power ON command on an already powered ON system and or a power OFF command on an already powered OFF system may return O command accepted Notes e In order to power on off a bullx blade the system running bsmBladepower must be declared on the target server as a member of a SNMPv1 read write community The default read write community name used by bsmBladepower is private e For the Power Off command to be taken into account on a remote host running Windows 2000 2003 Server the Shutdown Allow system to be shut down without having to log on security option must be enabled on the remote host To configure this security option a Click Start gt Run b In the Open box type gpedit msc and click OK c In the Group Policy window expand Computer Configuration Windows Settings Security Settings Local Policies Security Options d Set the Shutdown Security option to enabled bullx B5xx system Hardware Management CLI Reference Guide A Options h level a action a
67. on 549755813 BTU hr 549755813 BTU hr 549755813 BTU hr 549755813 BTU hr Max Power Time Last Minute Last Hour Last Day Last Week Min Power Time Last Minute Last Hour Tue Apr 06 13 47 58 2010 Tue Apr 06 13 24 33 2010 Mon Apr 05 14 37 09 2010 Sat Apr 03 19 55 13 2010 Tue Apr 06 13 47 58 2010 Tue Apr 06 12 34 19 2010 Last Day Mon Apr 05 13 34 19 2010 Last Week Tue Apr 06 13 47 58 2010 Enable power capping The enablePower action is used to enable power capping Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile M generation a enablePower Options M generation Model generation For novascale NS4xxF2 model model generation must be F Command bsmHWpm sh m lanplus H 199 182 100 160 u root p bull M F a enablePower Chapter 1 CLI command for bullx blades 1 37 1 7 3 26 1 7 3 27 1 7 3 28 Disable power capping The disablePower action is used to disable power capping Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile M generation a disablePower Options M generation Model generation For novascale NS4xxF2 model model generation must be F Command bsmHWpm sh m lanplus H 199 182 100 160 u root p bull M F a disablePower Get information about the share type for Ethernet port used by the BMC The getLan action displays the share type for the Ethernet port used by the BMC Syntax bsmHWpm sh h
68. oot a getCurrentFreq c 6 Set the current frequency for one or all CPUs The setCurrentFreq action is used to set the current frequency for one or all CPUs Syntax bsmOSpm sh h l level m model H host u user o outfile I idfile d cfgdir C configfile D pathdir a setCurrentFreq c CPU Options c Cpu CPU concerned by the action number all synth default value f freq CPU frequency to be set The userspace governor must have been set and loaded The frequency may be specified in kHz or as a percent of the maximum frequency possible hardware limit Command to set the frequency for all CPUs bsmOSpm sh m linux H 199 184 238 37 u root a setCurrentFreq f 2394000 c all Command to set the frequency for CPU 6 bsmOSpm sh m linux H 199 184 238 37 u root a setCurrentFreq f 2394000 c 6 Chapter 1 CLI command for bullx blades 1 5 1 11 2 5 Get the minimum and maximum CPU frequency allowed The getHWlimits action is used to obtain the minimum and maximum CPU frequency allowed Syntax bsmOSpm sh h 1l level m model H host u user o outfile I idfile d cfgdir C configfile D pathdir a getHWlimits c CPU Options c cpu CPU concerned by the action number all synth default value Command to get the frequency allowed for each CPU bsmOSpm sh m linux H 199 184 238 37 u root a getHWlimits c all 1596000 kHz
69. powered ON but not RUNNING due to a BIOS initialization error Syntax bsmpower sh h q a action m ipmidrv o outfile 1l level Chapter 1 CLI command for bullx blades 1 6 1 14 bsmreset 1 14 1 1 14 2 1 14 3 1 62 bsmreset sh is used to forcibly Power Reset a server When the command is accepted the return code is O If the command fails the return code is 1 If the server is not in the right state to perform the reset command an error is displayed Notes e Servers are identified by their DNS name or IP address H parameter Options h level q H host D domain m model M hwmanager U user p password Y cipher o ouffile Displays command usage Specifies the severity of the messages to be logged in syslog O no message is logged default 1 only the FAILED completion of the command is logged 3 FAILED and successful completion of the command are logged Quiet option stops all outputs stdout sdterr or outfile if o option is specified DNS name or target server IP address bullx blade IP address Target server domain name NovaScale 5005 and 6000 series only Target server model fame nec ipmilan lanplus tiger blade_CMC DNS name or PAP Manager IP address NovaScale 5005 amp 6000 series only PAP administrator for NovaScale 5005 amp 6000 series SMU user on the target server for NovaScale 4000 series BMC user for NovaScale
70. ptions p port SNMP port default value 161 S SNMPv SNMP version 1 default value 2c 3 C community SNMPv1 community default value public for status action L seclevel SNMPv3 SecurityLevel noAuthNoPriv authNoPriv authPriv u user SNMPv3 user A authPass SNMPv3 authentication passphrase 15 to 32 ASCII characters P authPro SNMPv3 authentication protocol default value MD5 X privPass SNMPv3 privacy passphrase 15 to 32 ASCII characters different than authPass x privPro SNMPVv3 privacy protocol default value DES c outlet number or name of one outlet of PDU default value all all outlets are switched on or off T timeout SNMP timeout default value 30 seconds Command to obtain the status for all outlets bsmPDUpower sh H 129 182 6 177 a status m apc S 3 L authPriv u user A authpass P md5 X privpass x des c all Power Distribution Unit 129 182 6 177 MODEL AP7922 Serial Nb 780904000484 Firm Rev v3 5 7 Outletl power Off 2 Outlet2 power Off 2 Outlet3 power Off 2 Outlet4 power Off 2 Outlet5 power On 1 Outlet6 power Off 2 Outlet7 power Off 2 Outlet8 power Off 2 Command to obtain the status for outlet 4 bsmPDUpower sh H 129 182 6 177 a status m apc S 1 C public c 4 Power Distribution Unit 129 182 6 177 MODEL AP7922 Serial Nb 780904000484 Firm Rev v3 5 7 Outlet4 power Off
71. r model ipmilan lanplus H host DNS name or target server IP address C crypt Cipher suite to be used by ipmilan model for lanplus encryption default value O means no encryption L priv Remote session privilege level ADMINISTRATOR default OPERATOR USER u user BMC user p password User password Y cipher Cipher suite ID to be used by lanplus interface default is 3 Usage Syntax bsmsol sh h m ipmilan H host u user p password 1l level C crypt L priv bsmsol sh h m lanplus H host u user p password l level L priv Y cipher Establish SOL session with ipmilan Command bsmsol sh m ipmilan H 129 182 6 50 u root p root SOL Session operational Use For help Shell gt Shell gt terminated ipmitool Chapter 1 CLI command for bullx blades 1 67 1 17 3 2 Establish SOL session with lanplus Command bsmsol sh m lanplus H 129 182 6 50 u root p root SOL Session operational Use For help Shell gt Shell gt terminated ipmitool 1 68 bullx B5xx system Hardware Management CLI Reference Guide Appendix A Server ON OFF Status Codes This appendix lists the interconnection between the ON RUNNING TRANSIENT OFF states returned by the bsmpower sh a status command and the server states OFF corresponds to server states INACTIVABLE INACTIVE TRANSIENT corresponds to server states POWERING ON POWERING ON FAILED TIMEOUT DURING POWE
72. re O no action 1 send alert 2 hard system shutdown via BMC T correctionTimeLimit Defines the max time in seconds in which the Node Manager must take corrective actions in order to bring the platform back within the specified power limit before taking the Exception Action r statisticsReportingPeriod Defines the Statistics Reporting Period in seconds Command bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a setNMPolicy i 0 g 0 x 380 c 0 T 500 r 20 Chapter 1 CLI command for bullx blades 1 27 1 7 3 9 Removes a Node Manager Policy The removeNMPolicy action is used to remove a Node Manager Policy Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a removeNMPolicy i policyID g policyTriggerType Options i policylD Policy ID g policyTriggerlype Policy Trigger Type 0 No Policy Trigger 1 Inlet Temperature Policy Trigger type Command bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a removeNMPolicy i 1 g 0 1 7 3 10 Get the Power Limit to be maintained on a policy ID The getPowerLimit action is used to get the Power Limit to be maintained for a policy ID Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a getPowerLimit i policyID Options i policylD Policy ID Command bsmHWpm sh m lanplus H 172 3
73. red on the target server as a member of a SNMPv1 read write community The default read write community name used by bsmpower is private Chapter 1 CLI command for bullx blades 1 57 1 13 2 1 58 Options h level a action a action H host D domain m model M hwmanager u user Y cipher idfile C configfile d cfgdir L Ipar f profilename p password B targetname S SNMPv C community P port T timeout o outfile Displays command usage Specifies the severity of the messages to be logged in syslog O no message is logged default 1 FAILED completion only is logged 3 FAILED and SUCCESSFUL completion are logged Quiet option stops all outputs stdout sdterr or outfile if the o option is specified Action on off off_force status restart The restart action is only available for Escala PL servers and logical partitions Action on off off_force status DNS name or target system IP address bullx blade IP address Target system domain name Target system model DNS name or Hardware Manager IP address User identification Cipher suite ID used by the lanplus interface default is 3 Identity key file for ssh connection ssh client configuration file for non prompt connection Directory in which the identity key file and ssh client configuration file are installed default value is etc ssh Logical partition name Name of the partition prof
74. sfer technology used to move data to and from computer storage devices such as hard drives and tape drives SATA Serial ATA A computer bus technology for connecting hard disks and other devices SEL System Event Log A record of system management events The information stored includes the name of the event the date and time the event occurred and event data Event data may include POST error codes that reflect hardware errors or software conflicts within the system A non volatile storage area into the BMC and associated interfaces for storing System platform Event information for later retrieval Server Hardware Console Graphical user interface used to access the management software embedded in the server module SHC See Server Hardware Console SIB SIBL System Interface Board The boards designed by BULL which contain the BCS Bull Coherent Switch Simultaneous Multi Threading See Multi Threading SMBIOS System Management BIOS SM BUS System Management Bus SMI System Management Interrupt SMP Symmetrical Multi Processor The processing of programs by multiple processors that share a common operating system and memory SMT Simultaneous Multi Threading SMTP Simple Mail Transfer Protocol SNC Scalable Node Controller The processor system bus interface and memory controller for the Intel870 chipset The SNC supports both the Itanium2 processors DDR SDRAM main memory a Firmware Hub Interface to support multiple
75. sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a getNumberOfCPUStates Number of P States available on the platform 9 Number of T States available on the platform 8 Get the maximum P State and T State The getMaxAllowedCPUStates action is used to get the maximum P State and T State Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a getMaxAllowedCPUStates Command bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a getMaxAllowedCPUStates Current maximum P State 5 Current maximum T State 4 Set the maximum P State The setMaxAllowedCPUPState action is used to set the current maximum P State Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a setMaxAllowedCPUPState s stateNumber Options s state Number P State number to be set from O to n 1 where n is the Number of P States returned with the getNumberOfCPUStates action available on the platform Command bsmHWpm sh m lanplus H 172 31 50 98 u ADMIN p ADMIN a setMaxAllowedCPUPState s 3 1 32 bullx B5xx system Hardware Management CLI Reference Guide 1 7 3 20 1 7 3 21 Set the current maximum T State The setMaxAllowedCPUTState action is used to set the current maximum T State Syntax bsmHWpm sh h 1l level m model H host u user p password o outfile z ME channel e ME a
76. state using the status option Note Power status represents the electrical status and not the functional status of the system For example a system may be powered ON but not RUNNING due to a BIOS initialization error Command bsmBladepower sh a status m blade_CMC H hwtest2 I 7 Output Command bsmBladepower sh a status m blade_CMC H hwtest2 I 7 Output Return Codes O Blade power is ON 1 Blade power is OFF OFF standby off standby on Command failed Chapter 1 CLI command for bullx blades 1 5 1 2 1 2 1 1 2 2 1 2 2 1 1 6 bsmevent bsmevent sh is used to add the events attached to a sensor to the SEL repository When the command is accepted the return code is O If the command fails the return code is 1 Options h level a action m model H host u user p password s sensorlD b state e eventDir i i2csaAdr Y cypher o outfile Displays command usage Specifies the severity of the messages to be logged in syslog O no message is logged default 1 only the FAILED completion of the command is logged 3 FAILED and successful completion of the command are logged Action setEvent Target server model lanplus ipmilan BMC target IP address BMC user User password Sensor identifier put between double quote State for the sensor identifier default is list Possible states are list Inr ler Inc unc ucr unr Direction taken
77. t handles I O requests for processors IPMB Intelligent Platform Management Bus Abbreviation for the architecture and protocol used to interconnect intelligent controllers via an 12C based serial bus for the purpose of platform management IPMI Intelligent Platform Management Interface A specification owned by Intel which describes mechanisms and devices to completely offload the task of managing system hardware from the primary CPU J JOEM JTAG Over Ethernet Module JTAG Joint Test Action Group K No entries Glossary g 5 L LAN Local Area Network LCD Liquid Crystal Display LCP Local Control Panel Module consisting of a controller a LCD color display a green and a blue LED and a Power ON button LDAP Lightweight Directory Access Protocol LED Light Emitting Diode Logical Partition When the Base Operating System is a Virtual Machine Monitor a logical partition is the software environment used to run a Guest Operating System Logical Processor See Thread M MAC Media Access Control MCA A Machine Check Abort exception occurs when an error condition has arisen that requires corrective action MESCA Multiple Environments on a Scalable Csi based Architecture MIB Management Interface Base MIMD Multiple Instruction Multiple Data MMX MultiMedia eXtensions MTB MTBC Memory and Tukwila Board Memory and Tukwila Board Controller MTBF Mean Time Between Failure Multicore Prese
78. target servers using the ipmilan model and for bullx blades User password Authentication key for Express5800 servers Cipher suite ID to be used by lanplus interface default is 3 Output file name to which stdout and stderr outputs are redirected Usage bullx blade servers Syntax bsmreset sh h q m blade_CMC H host u user p password o outfile 1l level bullx B5xx system Hardware Management CLI Reference Guide 1 15 bsmsensor bsmsensor is used to direct sensor values to the standard output This command is not available for NovaScale 5005 amp 6000 series servers When the command is accepted the return code is O If the command fails the return code is 1 The sensor values are displayed in stdout as follows lt sensor addr gt lt sensor id gt lt sensor value gt lt sensor unit gt lt status gt lt lower non recoverable gt lt lower critical gt lt lower non critical gt lt upper non critical gt lt upper critical gt lt supper non recoverable gt If the v option is specified one sensor is displayed per field over several rows depending on the format lt label gt lt value gt The fields and labels display may change according to servers and to sensors 1 15 1 Notes e Servers are identified by their DNS name or IP address H parameter e Sensor type see definition in IPMI specification may be specified either with the sensor type code in hex
79. the firmware version Command bsmFWupg sh t ipmitool a bulloemver H 129 182 6 110 u super p pass m ipmilan E LCP M 1 1 4 4 2 Upgrade BMC firmware Command bsmFWupg sh t ipmitool a bulloemupg H 129 182 6 110 u super p pass m ipmilan F fw_xxx bin E BMC 1 443 Display the list of the components that can be upgraded Command bsmFWupg sh t ipmitool a bulloemlisthw H 129 182 6 110 u super p pass m ipmilan MXBC ADM1069 4 A 98 ADM1069 4 A 9C ADM1069 3 B 98 ADM1069 3 B 9A Command bsmFWupg sh t ipmitool a bulloemlisthw H 129 182 6 110 MXBC ADM1069 4 A 98 ADM1069 4 A 9C ADM1069 3 B 98 ADM1069 3 B 9A 1 12 bullx B5xx system Hardware Management CLI Reference Guide 1 4 4 4 Display all firmware versions Command bsmFWupg sh t ipmitool a bulloemver H 129 182 6 110 u super p pass E all M 0 firmware version of LCP 20 firmware version of ILBC_BOOT A 4 4 0 01 00 firmware version of ILBC_FUNC B 4 5 0 F2 07 firmware version of o Er daa firmware version of ILBC B 4 5 0 F2 07 firmware version of MXBC C 4 F2 00 firmware version of ADM1069 4 A 98 12 01 10 firmware version of ADM1069 4 A 9A 12 02 10 firmware version of ADM1069 4 A 9C 12 03 10 firmware version of ADM1069 4 A 9E 12 04 10 firmware version of ADM1069 3_B_98 44 01 10 firmware version of ADM1069_3_B 9A 44 02 10 firmware version of ADM1069 3 A 98 44
80. tion on the internal authentication file add del getE getD list DNS name or PAP Manager IP address NovaScale 5005 and 6000 Series servers DNS name or platform Manager IP address NovaScale servers using the tiger nec or ipmilan model DNS name or FTP server IP address Generic Device IP address Manager or FTP server user Manager or FTP server user password Appendix B User Password Internal Authentication File B 3 B 2 2 1 Add a target add is used to add in the internal authentication file a target to the list of targets that can be accessed with a dedicated user password Syntax bsmcfg_auth_cmd sh a add u user p password M manager H manager S ftpserver D ipaddr Notes M or H or S or D parameter is mandatory Command to add a PAP Manager bsmcfg_auth_cmd sh a add u pap p pappwd M paptest2 Output Command to add a platform Manager bsmcfg_auth_cmd sh a add u MWA p mwapwd H 129 182 6 151 bsmcfg_auth_cmd sh a add u MWA2 p mwa2pwd H B 4 bullx B5xx system Hardware Management CLI Reference Guide B 2 2 2 Extract the encoded password getE is used to extract from the internal authentication file the encoded password needed to access a target with a dedicated user Syntax bsmcfg_auth_cmd sh a getE u user M manager H manager S ftpserver D ipaddr Note M or H or S or D parameter is mandatory Command to get the encoded pass
81. to eae oes eb ee dane E E 1 10 Vide NOES ines tect ney Aeaaen ee RAKE aa eae eae ee 1 10 144 2 OPHONS des deced anne aed evade hed aad highend dias tank peared es 1 10 1 4 3 Usage NovaScale servers updated via kiratool 0 20005 1 11 1 4 4 Usage Bull servers updated via ipmitool bulloem extension 1 12 1 5 bsmHWinfocmd 0 e cece e cece e bene eee eee eeeeneneees 1 14 ksl OPiONS eare be tiene tessa E aT Latif lates acca plo ee halal dss 1 14 1 6 bsmGetConfParam 4 n nnna nunnan babe end be abedwediakedabetabuieseewees 1 15 Een INOS ssc seb nee sanits Seta auld Mecatep gee ails Cade nae erage baatdeds 1 15 V0 2 OPOS 23424202 tanh Baer eer eae ee Senses 1 15 LOS NUSAGS 5 he cnet ate eke aah cae etn tee ee esate eek S 1 15 1 6 4 Usage Server using ipmilan or lanplus model 0002000 1 17 1 7 Dail Oil eree rasac inaa a a a a aa a EEE 1 21 Ll NOIES eoe e ee de ated eee 1 21 Z2 ODORS as paia see aE eer E A R E E 1 22 1 7 3 Usage Server using ipmilan or lanplus model 0020 00s 1 22 1 8 bsmidenhiiy oere eneren ems din ann att wane Seon ane E E EEEE ARRAN REN 1 40 Contents iii E E l Spent cannes fae we ha encine eevee ho wean pncu era ema ae 1 40 1 8 2 Usage bullx blade chassis amp bullx blade servers 00005 1 41 1 8 3 Usage Server using ipmidry model 25 04 2 chee es Rae eee ees 1 41 1 9 DSI sho enaa e AT E ee sid Gl tae hi ae AEs re Bt alt
82. ts are redirected M generation Model generation for NovaScale servers which name ends with an Fx model generation must be F z value Hexadecimal code of the manageability engine channel to reach default is 0x06 e value Hexadecimal code of the manageability engine address to reach default is Ox2c arglist List of arguments specific to the action 1 7 3 Usage Server using ipmilan or lanplus model Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile M generation a action arglist 1 7 3 1 Get the Total Power Budget The getPowerBudget action is used to get the Total Power Budget in Watts that is maintained by the Power Budget Control Service Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a getPowerBudget Command bsmHWpm sh m lanplus H 199 182 100 160 u root p bull a getPowerBudget Output 1 22 bullx B5xx system Hardware Management CLI Reference Guide 1 7 3 2 1 7 3 3 Set the Total Power Budget The setPowerBudget action is used to set the Total Power Budget in Watts that should be maintained by the Power Budget Control Service Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a setPowerBudget x value Options x value Total Power Budget to be set This value must be greater than the
83. ulloemver bsmFWupg a bulloemupg bsmFWupg a bulloemlisthw bulloemver display the component firmware version bulloemupg upgrade the the component firmware bulloemlisthw display the list of components which can be upgraded currently limited to module 0 This command is available only for ipmilan model NovaScale servers with Raritan Remote Management Modules that can be manipulated with the KiraTool command line tool and on Bull servers which use the bulloem command extension for ipmitool When the command is accepted the return code is O If the command fails the return code is 1 Notes e The KiraTool software that allows you to manipulate the module s firmware must be installed on the system running bsmFWupg sh Refer to the KiraToo User Manual for the installation procedure Options h Displays command usage D tooldir Installation directory of the KiraTool command line tool full path Default value is C Program files KiraTool for Windows and ust local bin for Linux F fw_binfile Name of the firmware binary file used during the upgrade d fw_bindir Directory where the firmware binary file is full path Default value is tmp H host DNS name or IP address to identify the module over the LAN t tool Command line tool kiratool ipmitool a action Action for a component identified by component_id on the E component_id module specified by module_id bulloemver display the firmware versio
84. wer level detected 7500 power 7500 5000 7000 0 1 56 bullx B5xx system Hardware Management CLI Reference Guide 1 13 bsmpower bsmpower sh is used to perform system POWER ON OFF and FORCE POWER OFF operations and to check the power state 1 13 1 bsmpower sh a bsmpower sh a bsmpower sh a bsmpower sh a on off off force status This command is asynchronous and returns the prompt before the end of command completion When the command is accepted the return code is O If the command fails the return code is 1 A power ON command on an already powered ON system and or a power OFF command on an already powered OFF system may return O command accepted An acknowledgement message is displayed in stdout except if the q option is specified Notes e For the Power Off command to be taken into account on a remote host running Windows 2000 2003 Server the Shutdown Allow system to be shut down without having to log on security option must be enabled on the remote host To configure this security option a Click Start gt Run b In the Open box type gpedit msc and click OK c In the Group Policy window expand Computer Configuration Windows Settings Security Settings Local Policies Security Options d Set the Shutdown Security option to enabled e Servers are identified by their DNS name or IP address H parameter e In order to power on off a chassis the system executing bsmpower must be decla
85. word o outfile 1l level s sensorid_list t type a c Usage Server using ipmidrv model Syntax bsmsensor sh h v m ipmidrv o outfile 1l level s sensorid_list t type a c Chapter 1 CLI command for bullx blades 1 65 1 16 bsmSetConfParam 1 16 1 1 16 2 1 16 2 1 bsmSetConfParam sh is used to set the values of various configuration parameters When the command is accepted the return code is O If the command fails the return code is 1 Options h Displays command usage level Specifies the severity of the messages to be logged in syslog O no message is logged default 1 only the FAILED completion of the command is logged 3 FAILED and successful completion of the command are logged a action Action setPowerRestorePolicy m model Target server model lanplus ipmilan H host BMC target IP address u user BMC user p password User password Y cypher Cipher suite ID to be used by lanplus interface default is 3 o outtile Output file name to which stdout and stderr outputs are redirected Usage Syntax bsmSetConfParam sh h l level a action m model H host u user p password Y cipher o outfile Set the power restore policy The setPowerRestorePolicy action is used to set the power restore policy On Off or Restore which will be apply to the system after an AC power loss Syntax bsmSetConfParam sh h a setPowerRestorePolicy
86. word to access a PAP Manager bsmcfg_auth_cmd sh a getE u pap M paptest2 Appendix B User Password Internal Authentication File B 5 B 2 2 3 Extract the password needed to access a target getD is used to extract from the internal authentication file the password needed to access a target for a user Syntax bsmcfg_auth_cmd sh a getD u user M manager H manager S ftpserver D ipaddr Notes M or H or S or D parameter is mandatory Command to get the password to access a PAP Manager bsmcfg_auth_cmd sh a getD u pap M paptest2 Command to get the password to access a platform Manager bsmcfg_auth_cmd sh a getD u MWA H 129 182 6 151 Command to get the password to access a generic device bsmcfg_auth_cmd sh a getD u devuser D 129 182 3 3 B 6 bullx B5xx system Hardware Management CLI Reference Guide B 2 2 4 Delete a target del is used to delete in the internal authentication file a target from the list of targets that can be accessed by a user Syntax bsmcfg_auth_cmd sh a del u user M manager H manager S ftpserver D ipaddr Notes M or H or S or D parameter is mandatory Command to delete a PAP Manager bsmcfg_auth_cmd sh a del u pap M paptest2 Command to delete a platform Manager bsmcfg_auth_cmd sh a del u MWA H 129 182 6 151 bsmcfg_auth_cmd sh a del u ftpuser S MyFtpServer Output Command to delete a generic device bsmcfg_auth
87. y Manufacturers ID 0x000157 Intel Domain Id 0 Policy enabled per Domain Node Manager policy control enabled Global Node Manager policy control enabled Policy Trigger Type No Policy Trigger Policy will maintain Power Limit Policy Type Power Control Policy Policy Exception Actions send alert disabled shutdown system disabled Power Limit 32767 Watts Print Correction Time Limit 600000 ms Policy Trigger Limit 32767 Statistics Reporting Period 30 s 1 26 bullx B5xx system Hardware Management CLI Reference Guide 1 7 3 8 Create or modify a Node Manager Policy The setNMPolicy action is used to create or modify a Node Manager Policy Syntax bsmHWpm sh h 1 level m model H host u user p password o outfile z ME channel e ME address a setNMPolicy i policyID g policyTriggerType x powerLimit G policyTriggerLimit c exceptionAction T correctionTimeLimit r statisticsReportingPeriod Options i policylD Policy ID g policyTriggerlype Policy Trigger Type 0 No Policy Trigger 1 Inlet Temperature Policy Trigger type x powerLimit Power Limit to be maintained G policyTriggerLimit Defines the Inlet temperature in Celsius to be used as Policy Trigger value This argument is mandatory only if the policy trigger type is set to c exceptionAction Defines the action to be taken if the maintained given policy power limit is exceeded over the Correction Time Limit Possible values a
Download Pdf Manuals
Related Search
Related Contents
Instruc 22292-037-901021.qxd Trust Audio-Video Station for iPod AV-8200Wi Plant Science Instrumentation GUÍA DEL USUARIO MODE D`EMPLOI 1. Lifetime warranty / Garantia vitalícia / Garantia de Guide d`utilisation User manual Manuel d`utilisation Manual de uso S\ \M Copyright © All rights reserved.