Home
User manual Arc Pad 48 Integral RGBW wireless
Contents
1. Two slots 8 5mm wide in the fixture base serve for mounting on the non flammable flat surface ArcPad 48 Integral Wireless DMX RGBW 65 4 Ensure that the structure to which you are attaching the fixture is secure Caution Overhead installation requires experience Fixtures may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do not install the device and consult installation with an expert Warning The antenna must be instaled on the fixture to keep declared IP rating of the fixture 3 2 Connection to the mains Fixtures must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulation The ArcPad 48 Integral W is equiped with with a 5 cored power data cable The 3 cores serve for the power supply and next 2 shielded cores are intended for DMX connection The power cores are coloured according to the following table Core Plug Terminal Marking This device falls under class one and must be grounded The data cores DMX are coloured according to the table e ArcPad 48 Integral Wireless DMX RGBW The power cable is connected to a junction box as shown on the picture below Screws Cover Fixture Screws Power
2. Wireless DMX RGBW 8 Error and information messages t M Er Temperature measuring error The message informs you that the LED module temperature sensor is defective MA Er Master error The fixture is set as a master and DMX console is connected to the fixture 9 Technical specifications Power supply e Electronic auto ranging e Input voltage 100 240V AC 50 60 Hz e Fuse T 2 5A H e Power consumption Power Max power consumption Typical power consumption Ambient mode All LED channels at full 2 LED Channels at full Temperature Full mode 60W 60W 25 C Eco mode 40W 40W Optic amp Effects e Light source 48 Luxeon Rebel LEDs RGBW e Available optical systems 12 25 45 and 45 x 15 e RGBW colour mixing e Built in colour macros e Adjustable strobe sequences e White colour balance adjusting eLumen maintenance Channels Power Lio One LED Full mode 90 000 Two LED Full mode 85 000 Three LED Full mode 85 000 All LED Full mode 85 000 L7 70 maintenance of initial lumen output in hours Electronics e Control USITT DMX 512 RDM e DMX protocol modes 4 2 3 4 8 control channels e Operations modes DMX Stand alone Master Slave e Manual control of all effects via RUNIT WTX e 3 user editable programs each up to 68 steps Wireless DMX RDM module e Compliance with USITT DMX 512 1986 amp 1990 and 512 A e Full DMX fidelity and frame integrity 20 ArcPad 48 Integral Wireless DMX R
3. data cable Power data cable Junction box Insert flat tip screwdriver Junction box when inserting wire DMX z Power Signal x L Live Signal al N Neutral GND Signal ground PE Earth gt TT Ni Power data cable Junction Junction Junction sd box Power data cable box Power cable e DMX cable The junction box allows to connect several fixtures in a daisy chain of the power data cable Use the 3 x 1 5mm power cable to connect the first junction box with the mains and the power data cable for connecting fixtures each other Do not overload the supply line and the connecting leads The max number of connected fixtures in a daisy chain depends on the input voltage 29 fixtures at power supply 230V for power cable 3 x 1 5mm 14 fixtures at power supply 120V for power cable 3 x 1 5mm You have to take into account the the length of power data cable circuit breaker etc at projecting of the fixtures installation 3 3 Installation of the barn doors You can install the barn doors to better define illuminated surface To install the barn door module 1 Disconnect the fixture from the mains ArcPad 48 Integral Wireless DMX RGBW 2 Put the top edge of the barn doors module into the second groove on the top side of the ra
4. running the link procedure at DMX transmitter After linking the level of DMX signal 0 100 is displayed in the menu item r InF SPEC gt rAdl gt r InF To unlink the fixture from DMX transmitter The fixture can be unlinked from receiver via the menu item r UnL SPEC gt rAdl gt r UnL NOTE After connecting the fixture to the mains the fixture always receives wired DMX signal for first 6 seconds of its operation though the wireless DMX is active ArcPad 48 Integral Wireless DMX RGBW 4 ArcPad 48 Integral RGBCW DMX protocol CEN 1 1 Mode Channel BEBE Value Type of control Red LEDs 0 255 Red LEDs saturation control 0 100 proportional 2 2 2 Green LEDs 0 255 Green LEDs saturation control 0 100 proportional 3 3 3 Blue LEDs 0 255 Blue LEDs saturation control 0 100 proportional White LEDs 0 255 White LEDs saturation control 0 100 proportional Colour macros 255 values No function for DMX mode 4 White for DMX mode 1 step 1 15 White tones cool gt warm proportional 16 Blue Blue full Red Green White 0 step 17 55 Red 0 Green gt up Blue full White 0 proportional 56 Light Blue Red 0 Green full Blue full White 0 step 57 95 Red 0 Green full Blue gt down White 0 proportional 96 Green Red 0 Green full Blue 0 White 0 step 97 134 Red gt up Green full Blue 0 White 0 proportional 135 Yellow green Red full Green full Blue 0 White 0 step
5. runs in a loop 17 ArcPad 48 Integral Wireless DMX RGBW Edit Editing a program The fixture offers 3 freely editable programs EPG 1 EPG 3 each up to 68 steps Every program step includes a fade time the time taken by the step s channel status to reach the desired level and a step time the total time occupied by the step in the program E g If F tim 5 second and S tim 20 second effects will go to the desired position during 5 seconds and after that they will stay in this position for 15 seconds before going to the next prog step 1 1 Use the UP DOWN buttons to find St AL menu and press the ENTER button 2 Use the UP DOWN buttons to select Edit menu and press the ENTER button 3 Use the UP DOWN buttons to select a program you want to edit PrG 1 PrG 3 and press ENTER button 4 Use the UP DOWN buttons to select a desired program step St 01 St 68 and press ENTER button 5 Use the UP DOWN buttons to select a channel you want to edit and press the ENTER button List of editable items P End a total number of the program steps value 1 68 This value should be set before start Programming e g if you want to create program with 10 steps set P End 10 rEd1 a red LEDs saturation 0 255 GrE1 a green LEDs saturation 0 255 bLu1 a blue LEDs saturation 0 255 Whi1 Whi4 a white LEDs saturation 0 255 MACr colour macros 0 255 Stro a s
6. the unit near naked flames During the operation the housing becomes hot up to 80 C Refer servicing to qualified service personnel This fixture falls under protection class Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection Do not connect this fixture to a dimmer pack LED light emission Risk of eye injury Do not look straight at the fixture s LEDs during operation The intense light beam may damage your eyes Keep compustible materials at least 20 cm away from the fixture If the fixture has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature Avoid brute force when installing or operating the fixture The fixture was designed for outdoor use This fixture must not be used for underwater installation 3 ArcPad 48 Integral Wireless DMX RGBW When choosing the installation spot please make sure that the fixture is not exposed to extreme heat or dust Avoid using the unit in locations subject to possible impacts The fixture body never must be covered with cloth or other materials Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened Make sure that the area below the installation place is blocked when rigging derigging o
7. 136 174 Red full Green gt down Blue 0 White 0 proportional 175 Red Red full Green 0 Blue 0 White 0 step 176 214 Red full Green 0 Blue gt up White 0 proportional 215 Magenta Red full Green 0 Blue full White 0 step 216 254 Red gt down Green 0 Blue full White 0 proportional 255 Blue Red 0 Green 0 Blue full White 0 step Shutter Strobe 0 31 Shutter closed step 32 63 Shutter open step 64 95 Strobe effect from slow to fast proportional 96 127 Shutter open step 128 143 Opening pulses in sequences slow gt fast proportional 144 159 Closing pulses in sequences fast gt slow proportional 160 191 Shutter open step 192 223 Random strobe effects from slow to fast proportional 224 255 Shutter open step Dimmer 0 255 Dimmer intensity from 0 to 100 proportional Dimmer fine 0 255 Fine dimmer intensity from low to high proportional White LEDs lit proportionally when Red Green Blue LEDs are saturated together 10 ArcPad 48 Integral Wireless DMX RGBW 5 Control menu map Default settings Bold EA pe je DA CSI IS SLA F dim Cur t eT AS EC S AOS AENA rAd O int 30 60 100 turn C eE On Off 11 ArcPad 48 Integral Wireless DMX RGBW IO ee O pe eras EA OFF 1 255 min ArcPad 48 Integral Wireless DMX RGBW Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 PrG 3 SPEC 6 Fixture menu To browse the fix
8. 8 Integral Wireless DMX RGBW FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR ArcPad 48 Integral Save it for future reference This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the device Please consider that damages caused by manual modifications to the device are not subject to warranty 1 Safety instructions DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT Make sure that the available voltage is not higher than stated on the rear panel of the fixture This fixture should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supplied consult your authorized distributor or local power company Always disconnect the fixture from AC power before cleaning removing or installing the fuses or any part Do not overload wall outlets and extension cords as this can result in fire or electric shock Make sure that the power cord is never crimped or damaged by sharp edges Check the fixture and the power cord from time to time Do not install
9. ANOLIS ArcPad 48 Integral W RGBW USER MANUAL ArcPad 48 Integral Wireless DMX RGBW Table of contents 1 Safety INSTRU CLIONS onserer reiia aaa aaea a vce Duaten dite a e aae aa aaa Ee aeaea aKa EERE A aaa tae 3 2 Fixture exterior VIEW enced rer AR E EEA hae al oe hae ee el NEN ROO a 5 Stalin dd a e e i a Ee ee 5 BS LMOUNting the fixture tl di EE a a aaa e aa a a a aea tit 5 3 2 Connection tothe MAINS ecrini tarea a T AA A eer Ne a e 6 373 Installation of the barn dOOrs snis a ea a a E a a A E a Eae aa a e a e ea 7 3A SELLING AMA CONTO EEA AE E E E E EE E E Pi tad a GE a es 8 4 ArcPad 48 Integral RGBCW DMX protocol cocooconnocococnnononnonoonnnonononnnnnonnnnnnnonnnnonnnnonnnnnnnnnnnnnnnnnnnnnnannannnnnnnnnnncnnss 10 5x CONtrol MEAN A A A Re shes 11 6 FIXtUPE MENGE iced Bela ee had Ma ei Aes Ge Maas Mae AL dae ie 13 6 LEXUS ASS A A kad bier ened ditt ae ere ted hae Sucre tad Seta eaten 14 G2 FIXCUPE informationen sean A A a EEE aai A a 15 6 3 Persa A aa a iis sa aeaa aa tenaaa iae ees 15 6 4 Manual ModE A RO 16 62S Test SOQUEN CO Sii iaae entat a a i i A A AAA aa i A aa al 17 AS lo RS A eba a eiai aa E dab Rea Sen Gad has sag O e aeaa aa eaea aoa Naa 17 6 7 Special FUNCIONA a A A A A A EE T E i hee ete at 18 TARDM A A AA I EEEE AAA AAA A dnd 19 8 ECFOM ANG INFOFMATION MESAS oir A EEE a Ae A dos 20 Di Technical SOeCITICATIONS iais 20 10 Cleaning and MAINTENANCE ini A A A AA An date RG do 23 ArcPad 4
10. GBW e Auto sensing of DMX frame rate and frame size e lt 5ms DMX latency e Operational frequency range of 2402 2480 MHz e Producer LumenRadio Antenna e Max gain 5dBi Strobe e Strobe effect with variable speed max 20 flashes per second e Pre programmed random strobe pulse effects Dimmer e Smooth 16 bit dimming from O 100 Rigging e Via two slots in the fixture base Temperatures e Maximum ambient temperature 40 C e Maximum housing temperature 80 C Dimensions mm ArcPad 48 integral W 170 83 min 196max 69 3 147 2 21 ArcPad 48 Integral Wireless DMX RGBW Junction box Weight e3kg Protection factor e P 67 Connection e Data power cable e junction box Included items e 1x ArcPad 48 Integral W e 1x Junction box e 1x User manual e 1x Gasket of cable grommet M20 PF P N 1305 1388 Optional accessories e Barn doors module in silver colour No 10980090 e Eggcrate top hat module without lenses No 10980091 Note By reason of the fast moving development of LED technology newer products may have better light parameters than previous products 22 ArcPad 48 Integral Wireless DMX RGBW 10 Cleaning and maintenance DANGER Disconnect from the mains before starting any cleaning or maintenance work Rinse off loo
11. al OFF Fixture is permanently linked 1 255 Time from 1 255 minutes dF SE Default Settings The menu item sets all fixture parameters to the default factory values 6 4 Manual mode mom DIED Use this menu for control the fixture without connected DMX console PrE C Preset effects control Select this menu to call up preset positions of the channel effects Man C Manual effect control Select this menu to control all channels via buttons of the control board 16 ArcPad 48 Integral Wireless DMX RGBW To control fixture channels 1 Use the UP DOWN buttons to find Man C menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select desired effect channel List of control channels rEd1 red LEDs saturations GrE1 green LEDs saturations bLu1 blue LEDs saturations Whil white LEDs saturations MACr colour macros Stro a strobe shutter dimr a dimmer F dim a fine dimmer 4 Press the ENTER button and use the UP DOWN buttons to set value press the ENTER button to confirm it 6 5 Test sequences ESE CE Use this menu to run demo test sequences without an external controller which will show you some possibilities of using the ArcPad 48 Integral 6 6 Stand alone setting ELO ALI The fixtures on a data link are not connected to the controller but can execute pre set programs which can be different for every fixture St
12. and alone operation can be applied to the single fixture or to multiple fixtures operating synchronously Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master MASt and the rest as the slaves SLA Up to 32 fixtures can be connected in a master slave chain Only one fixture can be set as the master This option does not function at wireless operation Note Disconnect the fixtures from the DMX controller before master slave operating otherwise data collisions can occur and the fixtures will not work properly See the chapters Stand alone operation and Master slave connection Auto Automatic playback This function allows you to select the program which will be played after switching the fixture on Selected program will be played continuously in a loop 1 Use the UP DOWN buttons to find St AL menu Press the ENTER button Use the UP DOWN buttons to select Auto item Press the ENTER button Use the UP DOWN buttons to select desired program Press the ENTER button to confirm the choice OF OP a o PLAY Playing program By enter to this menu a complete overview of all programs is offered from which the program to be run can be selected 1 Use the UP DOWN buttons to find St AL menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select desired program 4 Press the ENTER button The selected program
13. diator detail A and the bottom edge into the second groove on the bottom side of the radiator and tighten four locking screws M2 to secure this barn doors module on the radiator barn doors Lens module Radiator 5 A Insert barn doors module into the second groove Radiator Radiator Lock the barn doors module with the screws Never close the barn doors during fixture operation 3 4 Setting and control For setting DMX address selecting DMX mode and for another settings you need either Robe Universal Interface WTX or the RDM Communicator Please see the Robe Universal Interface WTX or RDM Communicator user manuals to get more information about this products The way how to connect these interfaces to the DMX data link is figured below 1 Robe Universal Interface USB cable Control PC ArcPad 48 Integral W CT Robe Universal Interface WTX Power cable ArcPad 48 Integral Wireless DMX RGBW 2 RDM Communicator ArcPad 48 Integral RDM Communicator Power data cable Junction box Power DMX data cable DMX512 RDM protocol The fixture is equipped with the Lumen Radio CRMX module and antenna for receiving DMX signal CRMX module operates on the 2 4 GHz band To link the fixture with DMX transmitter The fixture can be only linked with the transmitter by
14. fixture as a master or slave 1 Use the UP DOWN buttons to find A001 menu Press the ENTER button Use the UP DOWN buttons to select MA SL item Press the ENTER button Use the UP DOWN buttons to select either master MASt or slave SLA Press the ENTER button to confirm the choice UU 00 Note After switching on the ArcPad 48 Integralwill automatically detect whether DMX 512 data is received or not If there is no data received at the DMX input the display will start to flash with actually set address 14 ArcPad 48 Integral Wireless DMX RGBW 6 2 Fixture information p a INFO Use this menu to read useful information about the fixture status To display desired information 1 Use the UP DOWN buttons to find the InFo menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select the required menu item 4 Press the ENTER button to confirm the choice Po ti Power On Time Use the menu item to read the number of operation hours for each LEDs operating mode FuLL Max light output from the fixture totL the function shows the total number of the operation hours in the FuLL mode since the ArcPad 48 Integral has been fabricated rESEt the function shows the number of the operation hours that the ArcPad 48 Integral has been powered on in the FuLL mode since the counter was last reset In order to reset this counter to O you have to press and hold the UP and DOWN buttons and at the
15. function has to be set on before adjusting a white balance C bAL White Colour Balance The menu gives access to the setting of the white balance To set white colour balance Use a DMX controller or the Man C menu to set all LEDs on max saturation Use the UP DOWN buttons to find the Pers menu Press the ENTER button Use the UP DOWN buttons to select the C bAL menu Press the ENTER button and the rEd item will appear on the display Press the ENTER button and use the UP DOWN buttons to set new max value for the red LEDs Press the ENTER button to confirm the choice Use the UP DOWN buttons to select next colour the GrEn Repeat steps 6 7 for this channel 10 Use the UP DOWN buttons to select the last colour the bLuE and repeat steps 6 7 for this colour a CONAN RWN LoAd Load of LEDs The menu allows to choose 2 different operating modes for fixture FuLL Maximum light output EcO The light output is decreased by 25 In Po Init effect positions Use this function to set all effects to the desired positions to which they will move after switching the fixture on if DMX is not being received Note If DMX mode 1 is selected only values set at items MACr macro and dinr dimmer will be accepted rAd t Unlink time Use this menu to set time after that the linked fixture will be unliked from the transmitter if the transmitter does not transmit DMX sign
16. ory Users should not change the setting uPd M Updating mode The menu item allows you to update software in the fixture via either serial or USB port of PC 18 ArcPad 48 Integral Wireless DMX RGBW 7 RDM This fixture is ready for RDM operation RDM Remote Device Management is a bi directional communications protocol for use in DMX512 control systems it is the new open standard for DMX512 device configuration and status monitoring The RDM protocol allows data packets to be inserted into a DMX512 data stream without adversely affecting existing non RDM equipment By using a special Start Code and by complying with the timing specifications for DMX512 the RDM protocol allows a console or dedicated RDM controller to send commands to and receive messages from specific moving lights RDM allows explicit commands to be sent to a device and responses to be received from it The list of commands for ArcPad 48 Integral is the following Parameter ID DISC_UNIQUE_BRANCH DISC_MUTE DISC_UN_MUTE DEVICE_INFO SUPPORTED_PARAMETERS SOFTWARE_VERSION_LABEL DMX_START_ADDRESS IDENTIFY_DEVICE DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL SENSOR_DEFINITION SENSOR_VALUE DISPLAY_LEVEL DEVICE_RESET DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION STATUS_MESSAGES STATUS_ID_DESCRIPTION DEVICE_HOURS Please see the Robe Universal Interface user manual for detail description of RDM operation 19 ArcPad 48 Integral
17. r servicing the fixture Do not block the front objective LEDs with any object when the fixture is under operation The fixture becomes very hot during operation Allow the fixture to cool approximately 30 minutes prior to manipulate with it Operate the fixture only after having familiarized with its functions Do not permit operation by persons not qualified for operating the fixture Most damages are the result of unprofessional operation Do not attempt to dismantle or modify the unit Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons Please use the original packaging if the fixture is to be transported If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock etc ArcPad 48 Integral Wireless DMX RGBW 2 Fixture exterior view 1 Lens array 2 Radiator 3 Base YA 4 Data Power cord 5 Antenna 3 Installation 3 1 Mounting the fixture The ArcPad 48 Integral can be arranged in any position orientation The ArcPpad 48 Integral s radiator with LEDs is mounted on an adjustable bracket for tilt adjustment into many positions
18. same time press the ENTER button EcO Economical mode totL the function shows the total number of the operation hours in the EcO mode since the ArcPad 48 Integral has been fabricated rESEt the function shows the number of the operation hours that the ArcPad 48 Integral has been powered on in the EcO mode since the counter was last reset In order to reset this counter to O you have to press and hold the UP and DOWN buttons and at the same time press the ENTER button DM In DMX values Select this function to read DMX values of each channel received by the fixture tEMP Fixture Temperatures Select this menu to read the temperatures of the fixture Cur t the current temperature of the fixture inside Hi tE the menu item shows the max temperatures of the fixture inside since the ArcPad 48 Integral has been fabricated rSEt the menu item shows the maximum temperatures of the fixture inside since the counter was last reset In order to reset this counter to O you have to press and hold the UP and DOWN buttons and at the same time press the ENTER button Note The ambient temperature should not exceed 40 C The temperatures can be displayed in either C or F units see option tEM U in the menu Pers VErS Software Versions Select this function to read the software version of the fixture processor 6 3 Personality oc us 5 Use this menu to modify the ArcPad 48 Integral operating beha
19. se dirt with low pressure water spray Wash the housing with a soft brush or sponge and a mild non abrasive washing detergent Rinse it There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by a qualified person Should you need any spare parts please use genuine parts Specifications are subject to change without notice November 13 2013 23 ArcPad 48 Integral Wireless DMX RGBW 24
20. trobe shutter 0 255 dimr a dimmer 0 255 F dim a fine dimmer 0 255 F tim a fade time 0 25 5 seconds S tim step time value 0 25 5 seconds COPY this item duplicates the current prog step to the next prog step The item P End is increased automatically 6 Use the UP DOWN buttons to set a DMX value of the channel and then press the ENTER button 7 Use the UP DOWN buttons to select next channel and press the ENTER button 8 After having set all channels in the current program step press the MODE button to go by one menu level back and select another program step 6 7 Special functions COcr A LL rdML Code This menu item shows the first part of the RDM identification code rd MH Code This menu item shows the second part of the RDM identification code rAdl Wireless DMX The menu serves for reading of the wireless operation status r InF Wireless DMX information The menu item shows level of received signal in If the fixture is not linked to the transmitter no LI is displayed r UnL Wireless DMX unlink The item serves for unlinking the fixture from transmitter Ad Effect Adjustment The menu allows calibration of each LEDs array dMH DMX Values The menu item enables to control all LEDs before calibrating each LEDs array CAL U Calibrating unit The menu serves for fine current calibration of LEDs during fixture burn in at a fact
21. ture menu use the Robe Universal Interface WTX RUNIT VTX Run the RDM network on your computer and click with the right button of the mouse on the fixture and select the Remote LED display option from the menu list as shown below Ready 13 ArcPad 48 Integral Wireless DMX RGBW The Remote LED Display window will appear Now you can fullly control the fixture using the UP Down Enter Escape and Reset buttons RDM network 10 12 Eile Scan Tools Options View Help Ge Fear E Es 2 DMX Network AA ON a Device UID 52 53 00 2d 00 a3 root device 3 F DMX512 Current Personality Mode 3 y Identify Device off Y 1 DMX Start Address 13 2 Y Device Label Noname Device Reset warm y 7 Remote LED Display Ready 6 1 Fixture Address On 1 ites Use this menu to set the DMX address of the fixture or set the fixture as a Master Slave dM Ad DMX addressing Select this submenu to set a DMX start address To set a DMX address 1 Use the UP DOWN buttons to find A001 menu Press the ENTER button Use the UP DOWN buttons to select desired start address Press the ENTER button to confirm the choice 2 90 MA SL Master slave addressing Select this submenu to set the fixture as a master or slave Option d AbL deactivates master slave setting This option does not function at wireless operation To set a
22. viour DM Pr DMX preset Select this menu item to set a desired DMX mode Please refer to the chapter DMX protocol for detail description of each DMX mode DMH DMX input Use the menu to select mode of receiving DMX signal DMH DMX signal is received by means of the standard DMX cable 15 ArcPad 48 Integral Wireless DMX RGBW rAd DMX signal is received by means of the inbuilt wireless module rAd o the fixture receives wireless DMX and sends the signal to its wired DMX output The fixture behaves as Wireless Wired adapter Note the option DMH I is available in fixtures with new electronics and a software version 3 0 and higher DiSP Display adjusting This function allows you to change the display settings d On this function allows you to keep the display on or to turn off automatically 2 minutes after last pressing any button on the control panel d Int select this function to adjust the display intensity 30 min 100 max turn select this function to turn the display by 180 tEM U Temperature Unit Use this menu in order to display the fixture temperatures in desired units C or F bALA Balance Use this menu item to enable On or disable Off the white balance which is set in the White colour balance menu below f this function is set off the ArcPad 48 Integral will use maximum values 255 of saturation for red green and blue colour This
Download Pdf Manuals
Related Search
Related Contents
INDICE DEL DOCUMENTO tv led color - Hyundai Electronics LevelOne 150Mbps Wireless High Power Outdoor USB Network Adapter IPCop-Installationshandbuch Samsung <span style="unicode-bidi: embed;">מקרר ארבע דלתות נפח 951 ליטר ברוטו/825 ליטר נטו מדחס אינוורטר </span> מדריך למשתמש Life Fitness CSX-01 User's Manual Fundex Games 8461-00-13 User's Manual Micro AdAptAdor WiFi USB Copyright © All rights reserved.
Failed to retrieve file