1. Se ek Ree 5 URINE a BHO nd sd RENE PN IDEO E nio FR ADD QE Eno ACTED IR V RR 6 BHUPS SEODBIBE noneodipdenamd Dead Cri DOOR E OE an 6 BSS Orentatl liusscineniiadb Ru KEEN NERVE a 6 Drawing Pontio Mares titties 7 Designing the Bri Se oed R ia Fin da o Nien 8 Spacer Tool Settings on Bridges cere reor renun n run n uuu uuuuuu nua u Rau an aRSRSRER ERR SRSRSRRRERERERSRSRES 9 Rotatin SNCS PIANC iesuuiaeci i Fu ERRARE C Kn i RN RV M RR Mu Rr RERO RR 9 Evaluating the Connectors osscitiaiiwiieiaihisii iii KR RC nw nM b REM RAE 10 Milling Center CHANGES uisscikadviia vaa swE QU EV GEEK a CA AVR rd 11 New Icon for a Parked Job e erreur eua u nua nauuuuuuuuauuuuuuauaRauRRSRRSERRSSSSESERSESSSEREESSSESEREERSSEREERERERNS 11 Zirlux FC2 Mill Maintenance 1c correr rr rr rr enun unu n uana u nuu uuuuuuuuuua n na RSRSRRRERERESERERRRRSRSRSRENENS 11 Elux FCA Stale FAC COR saiia aariaa EM MR VERE RR R ERR RA 11 New Documentation Available correre rer eren aua n unu u nuu uuuuuua n RR RRSRSRRRERERESERERERESESRSRERERERES 12 Customer Support 800 537 6070 3 Bridges Bridge cases are unique in that they are designed as individual teeth and milled as one unit This document assumes familiarity with multiple restoration cases and other intermediate to advanced topics Refer to your User Manual for more
2. Bridges Dear ECO Community Members Everyone at EAD is excited to bring you the latest version of our EAD Dentist system software This version 4 6 software update is a direct response to your requests hope you ll agree that it provides even more capabilities and practical opportunities to use your EAD system for greater satisfaction for you your team and your patients Your 4 6 update features bridges Scanning designing and milling bridges chairside Plus new materials are coming out over the upcoming weeks to be able to take advantage of the advanced software solutions including Telio CAD from Ivoclar Vivadent long term provisional block in 40 and 55 mm sizes new sizes of IPS e max 16 mm longer anteriors and 32 mm anterior bridges and Zirlux FC2 a full contour zirconia single unit for now bridge block in the works Zirconia restorations require additional hardware sintering oven for final processing but your Henry Schein Zahn and lvoclar Vivadent representatives can inform you of the options Enjoy your EAD 4 6 experience Gary Severance DDS Chief Marketing Officer EAD Technologies 2 E4D CAD CAM System Version 4 6 EDU1079 A Table of Contents BIOS uicissim wai tibl Ra M mc ww drin Mn uM TURCA Rei DR 4 BGS Peal acl Ol ne dE DO edd bibi DRE RENE ODE nea ietnnseaeraar nts iat 4 Updated Block Recommendation Ch arT 1 ecce eere ee er uu uuuuuuuuuuauuuauauaRaRRRRRRRRERSERSESESESESESESSESESERERER 4
3. e pontic s E4D CAD CAM System Version 4 6 EDU1079 A When you rotate the model you will notice that the pontics have a solid base and are raised above the gumline 0 75 mm The gingival aspect of the pontic follows the contours of the edentulous tissue and can be adjusted utilizing the design tools Note If you are unsure whether the bridge will fit in the desired material block skip ahead to the Mill tab and verify that it does not say Please reorient the restoration to fit or try a different material Verify and or change your material selection in Settings then try moving the sprue position Once you are satisfied that the bridge fits in the block return to the Design tab to finish designing your bridge 6 Follow the normal design workflow except for the interproximal contacts 4 Adjust the interproximal contacts that touch unprepped teeth to the same contact strength that you normally use The contacts of the bridge teeth will be fused together to form the bridge so the actual contact strength is not a concern but the contact should be heavy enough to ensure a proper connection 8 When you are satisfied with your designs click the Mill tab Spacer Tool Settings on Bridges The default Spacer Tool settings are different on bridges to account for the larger Path of Insertion The normal maximum for the spacer is 0 20 mm On bridge cases the spacer defaults to 0 20 mm and can be increased to 0 30 mm A la
4. information Bridge Preparation Ensure the preparations for the abutment teeth are not angled in different directions If one is pointed towards the lingual and one towards the buccal there may be problems with path of insertion and overmilling Cantilever and Maryland bridges are not supported Updated Block Recommendation Chart Subject to Availability New IPS e max block for longer anteriors 16 mm and an anterior bridge block 32 mm Telio CAD blocks are intended for long term provisional restorations maximum wear of 12 months 40 and 55 mm Zirlux FC2 is full contour zirconia that can be milled with the E4D Milling Center Zirconia requires a sintering oven Individual restoration 20 mm and bridge block 55 mm release date pending Restoration P Anterior Anterior Posterior Inlay Material p full crown veneer full crown Onlay tae Bridges Paradigm Provisional E MZ100 Only Lava Ultimate IPS Empress CAD HT IPS Empress CAD LT IPS Empress CAD Multi IPS e max Anteriors CAD HT Only IPS e max Anteriors CAD LT IPS max CAD Impulse Telio CAD lIvoclar Vivadent Zirlux FC2 Burn Qut Blocks For cast or pr ssed indications only BOB EE Primary C Secondary 1 With manufacturer indication indication caution 4 E4D CAD CAM System Version 4 6 EDU1079 A Bridge Setup Tab A bridge is made up of two or more restorations that are connected On the Setup tab selec
5. lice Plane icon displays the mm area Minimum required thickness Zirlux FC2 9 mm o Telio CAD 12 mm o IPS e max 16 mm 7 Click View Model to activate it 8 Click the Gingival View Control arrow to view the model from underneath 9 Look for internal hangups blue seen through the stone model on the axial walls or occlusal surface Blue around the margin is expected due to the margin ramp If there are any hangups adjustments need to be made to the Spacer on the Design tab Call Customer Support for help on your first few cases of hangups on Bridges 10 E4D CAD CAM System Version 4 6 EDU1079 A Milling Center Changes New Icon for a Parked Job The Parked Job feature was introduced in Version 4 5 In this update a new icon has been added to indicate that a job has been saved When a job is interrupted by an error message or a manual cancellation of the job it is saved in Parked Job Only the most recent job is available in Parked Job EE When a job has been saved an icon will appear in the corner to notify you 1 To restart the interrupted job touch Parked Job Jobs interrupted by a power failure are not parked Pending Jobs lt no jobs gt Milling Jobs Parked Job X Finished Jobs Calibration Jobs Do NOT insert a new block for a Parked Job A new block will result in broken tools To restart the job with a new block use Pending Jobs louch Select Reinser
6. multiple restoration case Scan the prepped teeth the edentulous area and two or more unprepped neighbors to aid in design and alignment Bridge Orientation Set the Orientation for each tooth tab Good model alignment will aid Autogenesis with the design and is important for the bridge s Path of Insertion 6 E4D CAD CAM System Version 4 6 EDU1079 A Drawing Pontic Margins Draw a margin for each tooth in the bridge 1 Click the tooth number tab for each abutment and draw the margin on the selected tooth An edentulous space does not technically have a margin The margin is drawn to aid the design process 2 Click Trace and designate the position and extension of the base of the pontic on the gingival tissue to fit the appropriate contour EE am Ur es Do not go too far down the curve of the gingival tissue or you may not be able to fit the bridge in the block Customer Support 800 537 6070 Designing the Bridge With any multiples case it is generally best to start the Autogenesis process on a tooth with an existing neighbor In a bridge case that means starting with the abutments 1 Rotate to evaluate the position of the preview library tooth In this example the preview tooth is high because the system is attempting to match the height of the higher mesial data This may result in a distorted initial proposal T 3 Click Apply 4 Repeat these steps for the other abutment 5 Repeat these steps for th
7. rger default margin ramp of 1 mm is used to aid in stability Rotating Slice Plane The Slice Plane can now be rotated Place the center of the Slice Plane approximately where you want it and then hold down the Ctrl key while moving the mouse to rotate Customer Support 800 537 6070 9 Evaluating the Bridge It is important to evaluate the connections on the bridge and look for possible hangups The sprue will be on the mesial or distal side of the bridge 1 Click View Model to hide the model 2 Click Sim When the Simulation is run the connections between the teeth are displayed 3 Click Slice Plane twice When Slice Plane is activated on a bridge mill simulation the system measures the slice width If the slice is thinner than the material guidelines the slice displays as red It is important to slice the simulation through the thinnest part of the connectors yellow lines in the examples Posterior cases tend to have wider contacts with smaller embrasures and are unlikely to be thin Anterior cases have smaller contacts and larger embrasures Any thin area should be evaluated 4 Move the Slice Plane to a connector If the Slice Plane needs to be rotated to slice through the thinnest part hold down the Ctrl key while moving the mouse to rotate 5 Rotate the model to view the slice 6 If the slice is red adjust your embrasures and or contacts and try the simulation again Note that when the model is hidden the S
8. t each tooth on the anatomical model that is part of the bridge For each tooth you must select the restoration type 1 Select each tooth that is part of the bridge the abutment s and the pontic s 2 Select the Restoration Type for each tooth In the example below Tooth 19 is a Pontic and the abutment teeth are Crowns 3 Click Link The cursor changes to a chain symbol 4 Click the mesial and distal teeth of the bridge After each end of the bridge is selected the teeth turn purple The teeth are now designated as a bridge 5 Select the first tooth in the bridge and designate the Library Material and Shade The material and shade is duplicated on the other teeth in the bridge when you click on them 6 Select the remaining teeth in the bridge and designate the Library Library must be chosen for each restoration before you can continue to the Scan Tab Note If Library Material and Shade are chosen before linking the bridge The software will replace the Material and Shade of the remaining restorations with that of the highest tooth number after the link Multiple bridges can be created on the same arch Repeat the steps above to create another bridge Customer Support 800 537 6070 Unlinking a Bridge If there is an error in how the bridge was linked click Unlink and click on any teeth of the bridge in question Bridge Scanning The scanning procedure for a bridge is the same as that for a
9. t the partially milled block if it had been removed Follow the on screen instructions The milling restarts from where it was cancelled Zirlux FC2 Mill Maintenance It is necessary to clean the mill and change the water before milling Zirlux FC2 If the zirconia is contaminated with other materials it will turn green when sintered Cleaning after milling is recommended because the zirconia acts as a thickening agent with the water Zirlux FC2 Scale Factor See the manufacturer s Instructions for Use provided with the Zirlux FC2 blocks for processing instructions Zirconia shrinks in the sintering oven There are numbers on the side of the box that the blocks come in You must keep this box with the blocks Do not mix blocks from different boxes Each box can have a different amount of shrinkage The Milling Center asks for the Scale Factor before a Zirlux FC2 is milled The system will increase the size of the restoration according to this number This means you cannot test the fit of the restoration before sintering Customer Support 800 537 6070 11 New Documentation Available New documentation and new videos are available on the ECO Members page of www e4d com resources Questions Call E4D Customer Support 800 537 6070 www e4d com or e mail customersupport e4d com Copyright 2013 All rights reserved 12 E4D CAD CAM System Version 4 6 EDU1079 A