Home
        ТР 600 - sst
         Contents
1.     HATPEB    t                   Q9 Temperature scale     LED indicator   SWITCH OFF EMERGENCY       Indication of warming switched ON condition  WARM   O Control button    Fig  1  External view of the thermostat TP 600    Regulation of the required warming temperature and  switching OFF the thermostat is carried out by pushing of  the button t         One button push corresponds to one  temperature step on the device scale     Running over the scale values is recycled   18 19 20 21 22 23 24 25 26 27  C   SWITCH OFF  18 19 20 21      General regulation range is 18 27  C     At the shifting of the thermostat to its  SWITCH OFF  position   heating sections are to be de energized but the device stays  ON     While in operation  the device indicates on the front panel  the following     Actual ground temperature   A corresponding value on the scale blinks green color  In the event that an  actual ground temperature falls outside the scale limits  symbols      lt  lt     temperature below 18  C  and    gt  gt     temperature above 27  C    are blinking     Required preset warm temperature  A proper value on the scale blinks constantly     Warming  The  WARM  indicator gets red color when the thermostat applies  voltage to heating sections     Switching OFF   The  SWITCH OFF EMERGENCY   indicator gets green color in case if  user has switched OFF the warming system selecting  SWITCH OFF   on the temperature scale     Alarm signaling   While in operation  the thermostat controls op
2.    WARRANTY COUPON    THERMOSTAT TP 600    Release date         The thermostat TP 600 has been manufactured and tested  according to TU 3428 725 68134775 2011 has passed the  acceptance test and is certified disposable for service     QCD stamp Seller stamp here    Date of sale Seller signature       Buyer signature       CERTIFICATION    Certificate of Conformity No        MANUFACTURER   Special Systems and Technologies   LLC  141008 Proektiruemyj proezd 5274  build  7  Mytischi  Moscow region  RUSSIA  Hot line  8  800  775 40 42    Ay    THERMOSTAT    TP 600    TO CONTROL THE GROUND WARMING SYSTEM  GREEN BOX AGRO    USER S  MANUAL    P3A 00038 02 N UM     ec  ME67  POCC RU ME67 B07980    CONTENTS    Functional description              cc cece cece cece ence tence 3    Technical data  ee EE cia es ee Rd ae eee    Delivery kit  2 ei dea RP OR e a eS t    4  Controls and indication                  cece eee eee ee eens 5  Temperature control            0  cece eee e ence e eee e eens 7  Installation of the thermostat                cece cee e eee e eee ee 7  Warranty obligations           sees 13  ero  Emm 13  Warranty coupon           cece cece Ime 16    Certification   iia per eop dah dene adie ti eia 16    NOTES    DEAR CUSTOMER     Thank you for purchasing the thermostat TP 600   We are confident that our production will be equal  to your expectations and ensure a fair yield     FUNCTIONAL DESCRIPTION    The thermostat TP 600 is designed to control electrical  warming syst
3.  for single core heating sections     MOUNTING OF THE THERMOSTAT ENCLOSURE    Remove a cover of the thermostat enclosure  To do this  turn  four fixers on the cover in position  1  by using of a straight   edge screwdriver  slot of the fixer is to be in horizontal  position   thereafter the thermostat front panel with the    mounted plate can be removed  Fig  3                                 C     o     S f S  e    Q  SS   c3                                                                                 Holes for fixing the enclosure to the wall    e mp       Terminals    Thermostat enclosure     Enclosure cover    Fig  3  Enclosure and cover of the thermostat    TEMPERATURE CONTROL    At the ground warming till the temperature preset by user   with the tolerance till  1  C above the preset  the commutation  relay of heating sections and the  WARM   indicator are  switched OFF  supply voltage of sections is de energized     At decrease of ground temperature below the preset one   with the tolerance till  1  C below the preset  the  commutation relay of sections is closed and switches the  warming ON  The  WARM  indicator is switched ON at that   The process of switching ON OFF repeats itself cyclically to  maintain the preset temperature     Temperature regulation is performed by signals of the ground  temperature sensor installed in soil     INSTALALTION OF THE THERMOSTAT    Installation and connection of the thermostat must be  performed by a skilled electrician  All the 
4. connection works  must be performed when supply voltage 220V is  completely powered OFF     A list of tools and materials necessary for  installation        Corrugated plastic tube of diameter not less than 16 mm   a length depends on a place of the thermostat installation       Standard plastic k nsl rd e box  6 Flat blade screwdriver      Phase d b   rnpof supply voltage    PREPARING OF ELECTRICAL CONNECTIONS    Lead a power wire into the place of coming out of installation  wires of ground warming sections  The wire with a cross section  of not more than 2 5 mm can be connected to the thermostat     Apply power tnjr ec to the wire  find a phase power conductor  by using of a phase d bai rmpand mark it     Power off the supply voltage  All the works on the thermostat  installation are performed only when power voltage is off     Attention  We recommend to connect only one ground  warming section to one thermostat in order that plant  beds could be controlled separately by maintenance of  temperature conditions best suited for each plant    At the connection of several heating sections to one  thermostat and accordingly to one temperature sensor   overheating or an insufficient bed warming  where  temperature can not be measured by the sensor  is  possible because of various heat exchange conditions   Connection of several heating sections to one thermostat  is possible only when the section laying pitch is identical  on different beds    In this case a parallel connection o
5. d  through the manufacturer s fault and if recommendations for  installation and operation are followed     The warranty doesn t cover thermostats with defects due to  mechanical damages  improper installation  connection and  breaching of the operation conditions provided for this device   see User s Manual      When asking for the warranty repair it is obligatory to  provide the filled warranty coupon with the name of the  article and the Seller s stamp    CLAIMS    If the defects are detected during the period of warranty  service  the Buyer is recommended to address request to the  service centre of the manufacturer or its authorized  representatives in regions     6 5 4 3 2 1 6 5 4 3 2 1    eoooloe  jeooopoe                                        phase neutra temperature phase neutral temperature  220 VAC sensor 220 VAC sensor             C    double core heating cable    single core heating cable    Fig  4  Diagram of the thermostat connection to 2 wire electric network                      earthing  conductor  gt   of network Qo  e  external    screw  terminal  earthing  conductor  of network  6 5 4 3          2 1   rm   Q Q single core heating cable  tt    temperature  sensor    2    Fig 5  Diagram of the thermostat connection to 3 wire electric network    external  screw  terminal                      double core heating cable    12       CONTROLS AND INDICATION  View of the thermostat front panel with controls and indication  is shown in fig  1           BBIKI ABAPA
6. ems for ground under cover  in greenhouses   conservatories and other greenery chambers     The thermostat ensures the maintenance of the ground  temperature preset by user basing on data of the remote  temperature sensor     The device is equipped with a dust  and waterproof enclosure  with the ingress protection rating IP 56     The warming control is carried out by one button    TECHNICAL DATA                   Power supply 220V   Maximum load current 16A  3 5 kW   Power consumption 450 mW   Weight 350g  Dimensions 140x135x65 mm       Ingress protection rating       Protection class    IP56  ll       Temperature sensor  TSTO2     NTC 6 8 kOhm       Length of the sensor installation wire    2m       Allowable ambient temperature    from  5  C to  45  C                   Allowable related air humidity 80    Temperature control limits from  18  C to  27  C  DELIVERY KIT     Thermostat TP 600 1 pcs    Ground temperature sensor 1 pcs     External screw terminal to connect earthing wire 1 pcs     User s Manual 1 pcs  O Packing box 1 pcs    WARRANTY OBLIGATIONS    The manufacturer guarantees compliance of the thermostat  quality to the requirements of TU 3428 725 68134775 2011  if the transportation recommendations and installation and  usage instructions are followed     Warranty period for the product   24 months  from the date of beginning of operations     During the warranty period the Buyer has the right for repair  or replacement of the unit when detecting failures occurre
7. erability of temperature  sensors  All the system parameters are controlled the same by the  especial algorithm and at breaking down  shorting  overwarming they  are to be diagnosed by the switching on the  SWITCH OFF EMERGENCY   indicator of red color     6    The thermostat is installed directly in a greenhouse on its rigid  constructions  Fix the thermostat enclosure by four screws  though the holes 9     Pass electrical wires through appropriate gland entries of the  enclosure       supply leading wire to thermostat   through top entry  D16  big     e wire from heating section   through bottom entry D16   big        wire from ground temperature sensor   through bottom  entry D9  small     Perform the connection of wires to terminals of the   thermostat board  fig  4     for electrical networks without   earthing  fig  5     for electrical networks with earthing       power cable   to terminals  L  and  N       heating section   to terminals  Warm      e the temperature sensor wire is connected to the thermostat  by using of terminals  Sensors  installed on the board     Upon completion of all necessary connections  install the front  panel of the thermostat into home place and turn all fixers in a  clockwise direction in the  0  position  slots of fixers in vertical  position      After the installation of the thermostat front panel  the  thermostat can be supplied with power voltage 220 V       One bottom entry can be used for double core heating sections   two entries  
8. f several heating  sections should be performed in an independent connection  box and one wire should be laid out of this box in order to  connect it to the thermostat  diameter of the thermostat  terminal screws allows to directly connect only one heating  section      It is necessary to make sure that total power of heating  sections  connected to the thermostat  doesn t exceed    3500 W   8    INSTALLATION OF TEMPERATURE SENSOR    Installation of the ground temperature sensor is performed at  the stage of installation of ground warming sections  The  temperature sensor is to be placed into a corrugated plastic  tube  the bearing face of which is closed with a qc jd e plug  preventing ground and moisture ingress inside    The corrugated tube with the sensor inside is placed on the  level of the laid heating cable between its loops equally spaced  from them  Another tube end with the installation wire inside is  laid to the thermostat installation place  Excesses of the tube  and the installation wire are to be cut as needed  Fig  2                  LE ET PTI ES TET PSE    MMT    d                   Fig  2  Diagram of the temperature sensor installation    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Manual - Wavekrom  Speco Technologies CVC-190 User's Manual  Bedienungsanleitung Luftgekühlter Dieselmotor  施工 ・ 取扱説明書  DAMTEC® standard  NAVIGON 72 Easy  Aeneon DDR2 533Mhz 1024Mb  Usuario Autentia - I-Med  Osciloscopios de la serie 1000B de Keysight Guía del usuario  pBAsi-hU6 Pur DNA    Copyright © All rights reserved. 