1. HATPEB t Q9 Temperature scale LED indicator SWITCH OFF EMERGENCY Indication of warming switched ON condition WARM O Control button Fig 1 External view of the thermostat TP 600 Regulation of the required warming temperature and switching OFF the thermostat is carried out by pushing of the button t One button push corresponds to one temperature step on the device scale Running over the scale values is recycled 18 19 20 21 22 23 24 25 26 27 C SWITCH OFF 18 19 20 21 General regulation range is 18 27 C At the shifting of the thermostat to its SWITCH OFF position heating sections are to be de energized but the device stays ON While in operation the device indicates on the front panel the following Actual ground temperature A corresponding value on the scale blinks green color In the event that an actual ground temperature falls outside the scale limits symbols lt lt temperature below 18 C and gt gt temperature above 27 C are blinking Required preset warm temperature A proper value on the scale blinks constantly Warming The WARM indicator gets red color when the thermostat applies voltage to heating sections Switching OFF The SWITCH OFF EMERGENCY indicator gets green color in case if user has switched OFF the warming system selecting SWITCH OFF on the temperature scale Alarm signaling While in operation the thermostat controls op
2. WARRANTY COUPON THERMOSTAT TP 600 Release date The thermostat TP 600 has been manufactured and tested according to TU 3428 725 68134775 2011 has passed the acceptance test and is certified disposable for service QCD stamp Seller stamp here Date of sale Seller signature Buyer signature CERTIFICATION Certificate of Conformity No MANUFACTURER Special Systems and Technologies LLC 141008 Proektiruemyj proezd 5274 build 7 Mytischi Moscow region RUSSIA Hot line 8 800 775 40 42 Ay THERMOSTAT TP 600 TO CONTROL THE GROUND WARMING SYSTEM GREEN BOX AGRO USER S MANUAL P3A 00038 02 N UM ec ME67 POCC RU ME67 B07980 CONTENTS Functional description cc cece cece cece ence tence 3 Technical data ee EE cia es ee Rd ae eee Delivery kit 2 ei dea RP OR e a eS t 4 Controls and indication cece eee eee ee eens 5 Temperature control 0 cece eee e ence e eee e eens 7 Installation of the thermostat cece cee e eee e eee ee 7 Warranty obligations sees 13 ero Emm 13 Warranty coupon cece cece Ime 16 Certification iia per eop dah dene adie ti eia 16 NOTES DEAR CUSTOMER Thank you for purchasing the thermostat TP 600 We are confident that our production will be equal to your expectations and ensure a fair yield FUNCTIONAL DESCRIPTION The thermostat TP 600 is designed to control electrical warming syst
3. for single core heating sections MOUNTING OF THE THERMOSTAT ENCLOSURE Remove a cover of the thermostat enclosure To do this turn four fixers on the cover in position 1 by using of a straight edge screwdriver slot of the fixer is to be in horizontal position thereafter the thermostat front panel with the mounted plate can be removed Fig 3 C o S f S e Q SS c3 Holes for fixing the enclosure to the wall e mp Terminals Thermostat enclosure Enclosure cover Fig 3 Enclosure and cover of the thermostat TEMPERATURE CONTROL At the ground warming till the temperature preset by user with the tolerance till 1 C above the preset the commutation relay of heating sections and the WARM indicator are switched OFF supply voltage of sections is de energized At decrease of ground temperature below the preset one with the tolerance till 1 C below the preset the commutation relay of sections is closed and switches the warming ON The WARM indicator is switched ON at that The process of switching ON OFF repeats itself cyclically to maintain the preset temperature Temperature regulation is performed by signals of the ground temperature sensor installed in soil INSTALALTION OF THE THERMOSTAT Installation and connection of the thermostat must be performed by a skilled electrician All the
4. connection works must be performed when supply voltage 220V is completely powered OFF A list of tools and materials necessary for installation Corrugated plastic tube of diameter not less than 16 mm a length depends on a place of the thermostat installation Standard plastic k nsl rd e box 6 Flat blade screwdriver Phase d b rnpof supply voltage PREPARING OF ELECTRICAL CONNECTIONS Lead a power wire into the place of coming out of installation wires of ground warming sections The wire with a cross section of not more than 2 5 mm can be connected to the thermostat Apply power tnjr ec to the wire find a phase power conductor by using of a phase d bai rmpand mark it Power off the supply voltage All the works on the thermostat installation are performed only when power voltage is off Attention We recommend to connect only one ground warming section to one thermostat in order that plant beds could be controlled separately by maintenance of temperature conditions best suited for each plant At the connection of several heating sections to one thermostat and accordingly to one temperature sensor overheating or an insufficient bed warming where temperature can not be measured by the sensor is possible because of various heat exchange conditions Connection of several heating sections to one thermostat is possible only when the section laying pitch is identical on different beds In this case a parallel connection o
5. d through the manufacturer s fault and if recommendations for installation and operation are followed The warranty doesn t cover thermostats with defects due to mechanical damages improper installation connection and breaching of the operation conditions provided for this device see User s Manual When asking for the warranty repair it is obligatory to provide the filled warranty coupon with the name of the article and the Seller s stamp CLAIMS If the defects are detected during the period of warranty service the Buyer is recommended to address request to the service centre of the manufacturer or its authorized representatives in regions 6 5 4 3 2 1 6 5 4 3 2 1 eoooloe jeooopoe phase neutra temperature phase neutral temperature 220 VAC sensor 220 VAC sensor C double core heating cable single core heating cable Fig 4 Diagram of the thermostat connection to 2 wire electric network earthing conductor gt of network Qo e external screw terminal earthing conductor of network 6 5 4 3 2 1 rm Q Q single core heating cable tt temperature sensor 2 Fig 5 Diagram of the thermostat connection to 3 wire electric network external screw terminal double core heating cable 12 CONTROLS AND INDICATION View of the thermostat front panel with controls and indication is shown in fig 1 BBIKI ABAPA
6. ems for ground under cover in greenhouses conservatories and other greenery chambers The thermostat ensures the maintenance of the ground temperature preset by user basing on data of the remote temperature sensor The device is equipped with a dust and waterproof enclosure with the ingress protection rating IP 56 The warming control is carried out by one button TECHNICAL DATA Power supply 220V Maximum load current 16A 3 5 kW Power consumption 450 mW Weight 350g Dimensions 140x135x65 mm Ingress protection rating Protection class IP56 ll Temperature sensor TSTO2 NTC 6 8 kOhm Length of the sensor installation wire 2m Allowable ambient temperature from 5 C to 45 C Allowable related air humidity 80 Temperature control limits from 18 C to 27 C DELIVERY KIT Thermostat TP 600 1 pcs Ground temperature sensor 1 pcs External screw terminal to connect earthing wire 1 pcs User s Manual 1 pcs O Packing box 1 pcs WARRANTY OBLIGATIONS The manufacturer guarantees compliance of the thermostat quality to the requirements of TU 3428 725 68134775 2011 if the transportation recommendations and installation and usage instructions are followed Warranty period for the product 24 months from the date of beginning of operations During the warranty period the Buyer has the right for repair or replacement of the unit when detecting failures occurre
7. erability of temperature sensors All the system parameters are controlled the same by the especial algorithm and at breaking down shorting overwarming they are to be diagnosed by the switching on the SWITCH OFF EMERGENCY indicator of red color 6 The thermostat is installed directly in a greenhouse on its rigid constructions Fix the thermostat enclosure by four screws though the holes 9 Pass electrical wires through appropriate gland entries of the enclosure supply leading wire to thermostat through top entry D16 big e wire from heating section through bottom entry D16 big wire from ground temperature sensor through bottom entry D9 small Perform the connection of wires to terminals of the thermostat board fig 4 for electrical networks without earthing fig 5 for electrical networks with earthing power cable to terminals L and N heating section to terminals Warm e the temperature sensor wire is connected to the thermostat by using of terminals Sensors installed on the board Upon completion of all necessary connections install the front panel of the thermostat into home place and turn all fixers in a clockwise direction in the 0 position slots of fixers in vertical position After the installation of the thermostat front panel the thermostat can be supplied with power voltage 220 V One bottom entry can be used for double core heating sections two entries
8. f several heating sections should be performed in an independent connection box and one wire should be laid out of this box in order to connect it to the thermostat diameter of the thermostat terminal screws allows to directly connect only one heating section It is necessary to make sure that total power of heating sections connected to the thermostat doesn t exceed 3500 W 8 INSTALLATION OF TEMPERATURE SENSOR Installation of the ground temperature sensor is performed at the stage of installation of ground warming sections The temperature sensor is to be placed into a corrugated plastic tube the bearing face of which is closed with a qc jd e plug preventing ground and moisture ingress inside The corrugated tube with the sensor inside is placed on the level of the laid heating cable between its loops equally spaced from them Another tube end with the installation wire inside is laid to the thermostat installation place Excesses of the tube and the installation wire are to be cut as needed Fig 2 LE ET PTI ES TET PSE MMT d Fig 2 Diagram of the temperature sensor installation