Home

Product User Manual

image

Contents

1. 1 OO CONTENT gt INDEX oo CONTENT gt Index SAFETY INSTRUCTIONS gt Standards to follow page 02 PACKAGE gt Inside package 2 03 OPERATOR gt Functionality page 2 gt Manual release page 03 B gt Technical Specifications page 04 O4 INSTALLATION gt Installation dimensions o4 B gt Installation steps gt Installation map pageo7 A 05 TROUBLESHOOTING gt Final consumers instructions page o8 A gt Instructions for specialized installers 8 06 COMPONENTS TEST gt Capacitors connection scheme page 9 07 MAINTENANCE gt Maintenance 9 08 CONTROL BOARD MC2 gt Connections Scheme 09 O1 A SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 4 ATTENTION gt To ensure the safety of people itis important that you read all the following instructions Incorrect installation or incorrect use of the product can cause physical injury and material damage gt Keep these instructions in a safe place for future reference gt This product was designed and produced strictly for the use indicated in this manual Any other use not expressly indicated here could compromise the good condition operation of the product and or be a source of danger gt ELECTROCELOS SA is not responsible for the improper use of t
2. gt CAPACITORS CONNECTION SCHEME To detect which components have problems on an automated system sometimes it is necessary to conduct tests using a direct connection to a 230VAC power supply For this it is necessary to merge a 8uF capacitor to make the operator to work In the diagram below is shown how this link should be made and how to merge the different wires of the components NOTES gt To perform these tests you don t need to remove operator from where it is installed because this way you can know if connected directly to power supply it will work correctly gt The order of wiring capacitor to motor wires is not important as long you connect one wire to Brown wire of motor and the other one to Black wire of motor gt Common wire should always be connected to power supply gt reverse motor direction just replace Black wire with Brown wire of the operator on the power supply 230V Power Supply Common Blue OPERATOR LINCE Earth wire Capacitor m O7 MAINTENANCE 4 gt Clean stainless steel arm gt With a cloth soaked in lubricant spray wipe any residue that accumulates on the operators stainless steel arm gt Apply a small amount of spray lubricant on the arm and using a dry cloth remove the excess leaving a homogeneous layer of lubricant over thearm gt Lubricate pins
3. SAt Supports Us OPERATOR FUNCTIONALITY 4 The operator LINCE is a product developed exclusively for the automatic opening of swing gates Besides being pratical safe and powerful this product has a new function incorpo rated so that you can transform motor to apply on right leaves to left leaves This allows greater flexibility in the use of each operator Middle part Upper part Lower part Motor disassembly and assembly process in orderto transform motor must be done as follows 01 Loosen the screws that secure the Lower Part to Middle Part 02 Remove Lower Part OPERATOR gt FUNCTIONALITY Loosen the screws of the Middle Part 04 Remove Middle Part L1 O5 Rotate Upper Part 180 06 Assemble operator by tightening all components with the screws 07 Full transformed operator lima Mataviine OPERATOR MANUAL RELEASE 4 Remove the plastic cap from the rear Information engraved on the unlock shaft end D Unlock B Lock 02 Insert Release key on the unlock Rotate key 180 in the direction shaft indicated in the figure to unlock di O4 Operator unlocked Note To l
4. gt Remove front and rear caps gt Place a small amount of lubricant on the holes that contains support pins gt Install caps on the respective holders gt Check motor supports gt Make sure that supports remain well fixed on the pillars and gate to ensure proper functioning of the equipment N All tests must be performed by qualified personnel due to serious danger These maintenance measures must be applied every year in order to insure associated with the misuse of electrical systems proper functioning of the automated system Mataviins Mataviins PROFESSIONAL PROFESSIONAL y 01 Jo sajqed pelq pue uMOoJq y yams 3sn Aem y UI SJOJOW euo Aue 4 31ON se pue uo u ea 18 ue aq 4snw y CONTROL BOARD MC2 _ o8 gt CONNECTIONS SCHEME 7 WOOD AD 51192030 1049341 1 35 93914 0 14030 N 40 4 sels Z 1070W Z 1030 N 101 Buluado 511815 1210101 1030 T 4010 Castanh
5. HORIZONTAL INSTALLATION DIMENSIONS 4 gt EXTERIOR OPENING Opening mechanical stopper Opening direction EXTERIOR Axis of rotation of the gate center of the door hinge Closing mechanical stopper Axis of rotation of the motor INTERIOR on the front support X Distance between the centers of the Axis of rotation of the holes on the supports from operator motor on the rear support Opening angle x Y gt LINCE300 95 130 a140 130a150 600 a 605 gt LINCE400 95 160 a200 120 a180 695 a 700 gt 95 160 a 300 120 a 280 900 a 905 LEGEND Dimension X Horizontal distance between hinge axis of the door and the rear axle of the motor Dimension Y Vertical distance between hinge axis of the door and the rear axle of the motor Dimension W Distance between axis of the motor brackets O5 B PROFESSIONAL INSTALLATION gt INSTALLATION STEPS Pay attention to installation dimensions mentioned on pages 04 B O5 A 1 Fixing rear support gt The Rear support must be fixed to the pillar or wall using dimensions provided in the preceding pages be fixed using screws with mechanical bushing or chemical welding process or one of your choice since it provides an appropriate support o2 Fixing front support gt The Front support should be fixed to the gate
6. respecting height dimensions and distance to the rear support This may be fixed by using screws welding process or to choose another long as it provides a secure proper support 03 Remove caps and pins from motor gt Before installing motor remove caps and pins from motor gt At the end of the installation put back plastic covers for a better visual finish of the operator INSTALLATION J INSTALLATION STEPS lt Install operator on the supports gt The operator must be placed on both supports the same time to avoid leaving the operator suspended by only one of the supports To make the task easier you should unlock the operator in order to be able to stretch retract arm easily see page 03 B to get the correct position for supports 05 Test movement gt Install the pins removed earlier on each place with a small amount of lubricant for less friction gt Move the door manually to see if the door opens and closes uniformly and correctly without any irregular friction during its entire travel This will ensure that operator is not subjected to problems during operation 06 Connecting operator to control board and configuring control devices gt With the operator installed connect it to control board for system configura tion see control board user manual Must also configure the desired control devices transmitters wa
7. he product or other use than that for which it was designed gt ELECTROCELOS SA is not responsible if safety standards were not taken into account when installing the equipment orfor any deformation that may occur to it gt ELECTROCELOS SA is not responsible for the safety and proper operation when using components not sold by them gt Do not make any modifications to the operator components and or their accessories gt Beffore installation unplug the automatism from the source of power gt The installer must inform the client how to handle the product in case of emergency and provide this manual to user gt Keep remote controls away from children to prevent the automated system from being activated involuntarily gt The customer shall not under any circumstances attempt to repair or tune the operator Must call qualified technician only gt Connect the automatism to a 230V plug with ground wire gt Operator for outdoor and indoor use O1 B O2 PACKAGE gt INSIDE PACKAGE In the package you will find the following components gt 2 Swing operators LINCE gt Control Board gt 02 4Channel transmitters gt 02 Front supports gt 02 Rear supports gt Capacitors 8uF gt Photocells gt User s manual gt 2 Release keys Transmitter Photocel s Rear sy v PDOrts Capaci tor 8uF Release keys Contro 2 01 board Fr
8. ll switch etc and other additional components such as antenna warning light key selector among others It is important to respect this installation order Otherwise it is not possible to ensure correct installation and operators may not work properly gt INSTALLATION MAP gt INTERIOR gt EXTERIOR gt LINCE gt EXTERIOR gt KEY gt WARNING gt ANTENNA gt CONTROL PHOTOCELLS PHOTOCELLS PHOTOCELLS SELECTOR LAMP BOARD LEGEND gt Connection cables e Mataviine d TROUBLESHOOTING gt FINAL CONSUMERS INSTRUCTIONS Anomaly gt Motor doesn t work atall Procedure gt Make sure you have 230V power supply connected to operator and if itis working properly Behavior gt Still not working Procedure II gt Consult a qualified MOTORLINE technician 1 gt Open control box and check if it has 230V power supply 2 gt Check input fuses INSTRUCTIONS FOR SPECIALIZED INSTALLERS lt Discovering the origin of the problem 3 gt Disconnect motors from control board and test them by connecting directly to power supply in order to find out if they have problems see page 9 4 gt If the motors work the problem is on the control board Pull it out and send it to our MOTORLINE technical services for diagnosis 5 gt If the motors doesn t work remove them from installation site a
9. nd send to our MOTORLINE technical services for diagnosis gt Motor doesn t move but makes noise gt Motor opens but doesn t close gt Unlock motor and move gate by hand to check for mechanical problems onthe gate Unlock motor and move gate by hand to closed position Lock motor s again and turn off power supply for 5 seconds Reconnect it and send order to open gate using transmit ter gt Encountered problems gt Consult an experienced gate expert 1 gt Check all motion axis and associated motion systems related problem with gate and operators pins hinges etc to find out what is the gt Gate moves easily gt Gate opened but didnt close again gt Consult a qualified MOTORLINE technician 1 gt Check if there is any obstacle in front of the photocells 2 gt Check if any of the control devices key selector push button video intercom etc ofthe gate are jammed and sending permanent signal to control unit 3 gt Consult a qualified MOTORLINE technician 1 gt Check capacitors testing operator with new capacitors 2 P If capacitors are not the problem disconnect motors from control board and test them MOTORLINE control boards have LEDs at easily allow to conclude which devices are with anomalies All safety devices LEDs DS in normal situations remain On All START circuits LEDs in normal situations remain Off If LEDs devices are no
10. o Castanho 3467 Fio Terra Fio Terra e oo 9 258 d d LAV 3802 oroni YSNYd 1
11. ock operator so it can work automatically must do it by turning the key anticlockwise OPERATOR gt TECHNICAL SPECIFICATIONS LINCE specifications are as follow gt Power Supply AC230V 50 60Hz AC230V 50 60HZ gt Power 180W 180W 180W gt Current 13 13A 13A gt RPM 1400 RPM 1400 RPM 1400 RPM gt Noise level 5odB 5odB lt 50dB gt Force 2300N 2300N 2300N gt Operating temperatures 25 C a 75 25 75 25 75 gt Thermal protection One 120 C 120 C gt Protection class IP54 1 54 1 54 gt Working frequence 25 25 25 gt Course 300mm 4oomm 600mm gt leaf lenght 2500mm 3ooomm LINCE 300 400 600 dimensions are the following 962mm n62mm 1562mm 175mm 647mm 747mm 947mm 159MM 104mm 4 INSTALLATION VERTICAL INSTALLATION DIMENSIONS 4 The operator LINCE must be installed with a small inclination to prevent water infiltration through the extension arm For this the front support must be fixed to the gate with a height lower than the height of the rear support See example below Dimension A Vertical distance from the floor to the top of the rear support Dimension B Vertical distance from the floor to the top of the front support Set dimension A this can be any size of your choice B Afteryou set dimen
12. sion A subtract 10mm to find dimension Example gt If the height of the rear bracket dimension is set at mm then the height of the front bracket dimension will be 590 mm assured the correct functioning and durability of the operators It is very important that these dimensions are respected Only this way can be It is also very important to have a levelled ground terrain INSTALLATION gt HORIZONTAL INSTALLATION DIMENSIONS On the Illustrated diagrams below and on the next page are the horizontal dimensions for the installation of the automated system INTERIOR OPENING Axis of rotation of the motor on the front bracket EXTERIOR Closing mechanical Axis of rotation of the gate stopper center of the door hinge Distance between the centers of the holes on the supports from operator Axis of rotation of the motor on the rear support Opening direction INTERIOR Opening mechanical stopper Opening angle X Y gt LINCE300 95 100 150 100 a 140 895 a 900 95 120 a180 120 a180 1095 alloo gt LINCE400 120 160 a180 1204140 1095 a 1100 95 350 120 a200 1495 a 1500 gt LINCE600 120 200 a 280 120 a200 1495 a 1500 It is very important that these dimensions are respected Only this way can be assured the correct functioning and durability of the operators O5 A INSTALLATION
13. t all On there is some security systems malfunction photocells safety edges etc If START circuits LEDs are turn On there is a control device sending permanent signal by connecting directly to power supply in order to find out if they have problems see page o9 A for diagnosis A SECURITY SYSTEMS Close with a shunt all safety systems the control board check manual of the control board in question If the automated system starts working normally check for the problematic device 2 gt Remove one shunt at a time until you find the malfunction device 3 Replace it for a functional device and check if the operator works correctly with all the other devices If you find another one defective follow the same steps until you find all the problems If the motors work the problem is from control board Pull it out and send it to our MOTORLINE technical services 4 gt If the motors doesn t work remove them from installation site and send to our MOTORLINE technical services for diagnosis B START SYSTEMS Disconnect all wires from START terminal input 2 gt If the LED turned Off try reconnecting one device at a time until you find the defective device NOTE In case procedures described in sections A and don t result remove control board and send to our technical services for diagnosis gt Motor doesnt make complete route gt Unlock motor and move gate b
14. y hand to check for mechanical problems on the gate gt Encountered problems gt Consult an experienced gate expert 1 gt Check all motion axis and associated motion systems related with gate and operators pins hinges etc to find out what is the problem gt Gate moves easily gt Consult a qualified MOTORLINE technician 1 gt Check capacitors testing with technical services for diagnosis 4 P If motors work well and move control unit and send it to gate at full force during the entire course the problem is from controller Set force using trimmer on the board Make a new working time programming giving suffient time for opening new capacitors 2 P If capacitors are not the problem disconnect motors from control board and test them by connecting directly to power supply in order to find out if they are faulty services 5 gt If this doesn t work remove MOTORLINE technical services NOTE Setting force of the controller should be sufficient to make the gate open and close without stopping but should stop with a little effort from a person In case of safety systems failure the gate shall never cause If the motors doesn t work remove them from installation Site and send to our MOTORLINE and closing with appropriate force see manual of the controller in question physical damaged to obstacles vehicles people etc O8 A OG COMPONENTS TEST

Download Pdf Manuals

image

Related Search

Related Contents

Nugget User Manual    AVH-P5180DVD  取扱い説明書DTC-N10~1000EXL  Etude de la qualité thermique du bassin des Dranses 2007-2008  JOF001EUP  Profitez des lunettes EDGE 1.1+ sur votre projecteur 3D  • CONCORD FUSION • CONCORD NEO _ D // GEEIGNETE BUGGY  3Com V7350 Network Card User Manual  Reindeer Technologies Pvt Ltd  