1. rated output unit voltage 125 250VAC 50 60HZ output unit rated current 10A Max total current load 16A 32A operation state 1 LED Master subordinative state 1 LED Output address temperature humidit Display P P y 3 LED address current load value 3 LED temperature humidity value Produc product size LxWxH X x88 8x44 4 mm Dimension mounting hole X according to the total length Temperature Working range 40 C 124 C temperature humidity Accuracy 1 C Response time 4s Technology Accuracy 5 RH humidity Requirement Response time 4s network port 1 RJ45 port 232 485 port 1 RJ45 port daisy chain port 1 RJ45 port software upgrade port 1 RJ45 port Control ports temperature humidity sensor port 3 RIIT port Smoke sensor port 1 RJ11 port waterlogging sensor port 1 RJ11 port door open close sensor port 2 RJII port spare sensor port 1 RJllport Current Load total current load Full scale 32A 16A Accuracy 1 2 26 Vertical PDU remote PDU User Manual Display Full scale 10A individual current load Technology Accuracy 1 1 8 Housing color black Installation bracket 1 set Normal network connection wire 2M blue 9 Accessories daisy chain connection wire 2M yellow user manual 1 set CD temperature humidity sensor Optional Smoke sensor 10 sensor Accessories door sensor waterlogging sensor Working working tempera
2. D Click New User to enter new user creating interface Creat a new user Wiser Mame Password Verify Password Liser Level Administrator Apply Reset Liser Manage Control Rights E Click Edit under Level to edit user s name and password F Click Edit under Control Rights to set user authorities G Click Remove to delete the corresponding user 14 Reset System Click Restart under the Main Guide Menu and click Restart on the WEB interface reset RPDU system 15 Logout System Click Logout under the Main Guide Menu and click Yes on the WEB interface logout RPDU system 5 RPDU Daisy chain Method amp Configuration 23 Vertical PDU remote PDU User Manual 1 Daisy chain Method A Firstly connect and configure one master RPDU and then subordinative RPDUs confirm the connection is correct When present RPDU is in subordinative state indicated with off M S Master RPDU indicator press RESET button for 12 seconds until M S indicator flashes Configuration about six times and when M S indicator is lighted present RPDU master RPDU is successfully configured When present RPDU is in master state indicated with on M S indicator Ge E press RESET button for 6 seconds until M S indicator flashes about three times and when M S indicator is off master RPDU is successfully Configuration
3. Users connect computer with the network through LAN and WAN then open IE and input the IP address of RPDU to access then can monitor control and manage the power supply of equipments connected to the RPDU a Default IP is 192 168 1 163 b Default User Name adm password adm c Recommended computer display resolution is 1024 768 2 SNMP monitoring Administrator can check the unnormal operation state of RPDU through the SNMP Simple Network Management Protocol system flat 4 HTML Interface HTML Interface includes three parts RPDU System Information Interface User Guide Menu and Main Controlling Interface RPDU System Information Interface including information of company logo company website the IP of current RPDU 12 Vertical PDU remote PDU User Manual User Guide Menu displaying user s login name and easy operated Web interface to access and guide user to finish operation quickly and conveniently As the below interface Current User adm Curent User Name Basic Sensor NPDU Configuration Network Threshold Value Alarm settings Alarm Logs Timer switch Advance System Infor Advanced Function Interface Main Controlling Interface on the right side of User Guide Menu is the main controlling interface and all the web page will be showed on this interface The default main page shows present RPDU information RPDU series No and version No individual output unit controlling menu total
4. NET Port of Master RPDU 3 Connect one end of attached network line to LINK port of Master RPDU the other end to one IN OUT port of the HUB 4 Connect one end of second network line to another IN OUT port of the HUB the other end to the SER port of first Subordinative RPDU then connect one end of third network line to another IN OUT port of the HUB the other end to the SER port of second Subordinative RPDU and 10 pieces RPDU at most can be connected together 5 Access to software control interface through IE web browser details please refers to Software Introduction 11 Software Updation Method A NPDU2S hex HEX z 32 KB 1 When Software Updation File is available and please save it in PC philips_flash_ut WinRAR ZIP kiaii 2 Open Software Updation File 2 058 KB then double click this file to install the software 3 Run the installed software the following Interface will come out CG LPC2000 Flash Utility PHILIPS LPC2000 Flash Utility v2 2 2 Flash Programming Erase Blank Communication SS 8 Connected To Port ER Blank Check Entire Device cOMt x Selected Sectors Execute Code Use Baud Rate eech Vv after Upload Start Sector zz 9600 v Erase Compare Flash Manual Reset pes ee RW Time Out sec 5 Device Use DTR RTS Device LPC21 31 Part pd Vv for Reset and Boot Loader Read XTAL Freq kHz fi 10592 Device ID Boot Loader pd Selection 4
5. Please insert one end of RJ45 connector of the Software Updation Line into the Portl of RPDU Vertical PDU remote PDU User Manual and the other end of DB9 connector into the RS232 port of PC Communication Connected To Port COM1 MM 5 Please choose the correct series port in and make other options according to the following illustration diagrams Flash Programming l 8 NPDUDS hex Filename lasal HEX we BEEE Bee i RS 32 KG 6 Click ES and add into dialo gue interface 7 Power on RPDU Read 8 Click Device ID and Read Part ID Successtully will come out to indicate reading successfully If not please check relevant connection line and communication port Erase 9 tick Dm and E ased LPC2000 Flash Successtully wil come out to indicate erased successfully If not please check relevant connection line and communication port Upload to Flash 5 10 Click and Executing Uploaded Code wil come out to indicate executing successfully If not please check relevant connection line and communication port 11 Power off RPDU 12 Then power on RPDU Display Board will show new version number to indicate successful software updation and then it can work normally Vil RPDU Software Introduction 1 Software Overview The software of RPDU is embedded applications software On the base of the monitoring and controlling technology of SNMP and integrating a variety of high tech as sen
6. controlling menu individual output unit name individual current load total current load of individual RPDU sensors monitor information of individual RPDU and other parameter configurations 1 Login Method A Run IE Internet Explorer and input the IP address of the RPDU then input the login name and password on Login Dialog Interface and finally click yes button to enter the HTML Interface of RPDU system B Users have three chances to login further wrong login name or password input the system will automatically login out the Login Dialog Interface users have to repeat operation step A 2 OUTLETS Controlling 13 Vertical PDU remote PDU User Manual Select Device NPDUL z _Refresh NPDU1 status NPDUZS B No Output Name Current Amps Output Status ON OFF Control 1 Output 1 0 0 NONE e 2 Output 2 0 0 e NONE e 3 Output 3 0 0 E NONE 7 4 Output 4 0 0 B NONE X 5 Output 5 0 0 e NONE 7 6 Output 6 0 0 E NONE e 7 Output 7 0 0 E NONE e 8 Output 8 0 0 NONE e 9 Output 9 0 0 E NONE 7 10 Output 10 0 0 Ei NONE 7 11 Output 11 0 0 NONE 7 12 Output 12 0 0 EN NONE v Total Current 0 0 Apply Cancel Global Control All Outlets NONE z Apply Cancel View Voltage and Energy A The above RPDU Controlling Interface can be accessed by clicking Device Control on User Guide Menu B Under the pull down menu of Select Device lists the names of daisy chained RPDU users can
7. 2 5 Daisy chain Method amp Configuration 0 0 0 0 ec ce cence cence ene eee e neta ene ne en eneeeneeee eae ee ed 13 6 FAQ and E e CG 24 Vi Operation EE 25 IX Performance amp Technical Parameter Table 25 X Quality Guarantee Policy 25 lt ice0 ica dees Re eg dE Ee SEENEN 27 Vertical PDU remote PDU User Manual I RPDU Introduction RPDU can monitor control and manage the power supply of electrical and electronic equipments in standard and non standard cabinets all over the world through LAN or WAN RPDU can be accessed by different connection methods to satisfy different requirements in different environment can be accessed through RJ45 interface in the LAN and WAN can be accessed through standard network management station II Function Description 1 Monitoring Function monitor the operation of present RPDU total current load individual current load not available for A series power on off state of individual output unit not available for A series temperature humidity state Smoke state waterlogging state door open close state through the display interface and knob on RPDU And also can monitor control and manage through LAN or WAN 2 Controlling Function not available for A series control the Power on off of output units Schedule the interval time of sequential power on off Setting Power On Off of output units 3 Original State Keeping Function not available for A series Keep the orig
8. F Product Modeloa Total Socket ou Quantity e g 24 finally displays Output Unit No and its corresponding current load value and at this point LED Operation Indicator will flash And Master RPDU is indicated with M S Indicator lighted on and Subordinative RPDU with M S Indicator off 2 Monitoring Current Load Temperature amp Humidity Monitoring corresponding current load value output unit by turning button No 1 select No 2 reset 3 Monitoring Waterlogging amp Smoke State 1 When waterlogging state is detected RPDU Display Board displays F2 and Alarm Buzzer rings at the same time 2 When Smoke state is detected RPDU Display Board displays Fl and Alarm Buzzer rings at the same time Vertical PDU remote PDU User Manual 4 Monitoring Operation Fault of output units When one output unit fails to work normally for example Al RPDU Display Board will display corresponding fault for example Al Err and Alarm Buzzer will ring at the same time 5 Monitoring and Alarming When Exceeds Preset Alarm Threshold Value 1 Alarm when the actual value of individual output unit current load total current load and temperature amp humidity are lower than preset limited min value For example when any of the above situation happens at output unit Al RPDU Display Board will alarm by displaying A 1 and Alarm Buzzer will ring to alter related administrator 2 Alarm when the actual value of individu
9. Network Information Configuration Current User adm e Network settings Basic e i NPDU Control Obtain an IP address automatically Sensor Use the following IP address NPDU Configuration A z IP v4 Address 192 168 1 181 Threshold Value Subnet Mask 259 259 259 0 Alarm settings Default Gateway 192 168 1 1 alee Primary DNS 202 96 128 86 gt Timer switch Secondary DNS 202 96 134 133 Advance System Infor The above network configuration interface is used to configure RPDU network information RPDU administrator can configure RPDU IP address subnet mask gateway address DNS A Default IP address by clicking Obtain an IP address automatically B Clicking Use the following IP address button to configure the network information Default IP Address 192 168 1 163 Default Subnet Mask 255 255 255 0 Default Gateway 192 168 1 1 RPDU IP address PC connected with LAW and other network devices can not be the same as PC IP address but RPDU IP address and PC IP address must be in the same network segment C Click Apply button then all the above settings will be saved Attention Power off RPDU to restart the configured information will be valid 6 Controlling Power on off Power on off controlling is according to the needs administrator sets the time that power on off 17 Vertical PDU remote PDU User Manual and the system will automatically control the power on off state of
10. Vertical PDU remote PDU User Manual RPDUV Vertical User Manual RPDU remote PDU also called as NPDU Network PDU Vertical PDU remote PDU User Manual Contents E E RE 3 I SBN CTO EE 3 PD a sn ble EE 4 IV Product Diagram and Exvplanatton 5 r EE E EEN 6 Vi REDU Hard ware Introduction joes sss creas ese ee een ome oo 6 Ls Powering on amp Self detection ee Ee gece Eege Ee Ee 6 2 Monitoring Current Load Temperature amp Humidity AAA 6 3 Monitoring Waterlogging amp Smoke State 6 A Monitoring Operation Baul trcrtsts cate e AA E A O Sos ved EEE S 7 5 Monitoring and Alarming when Exceeds Preset Alarm Threshold Value 00 cece eeeeeee ee eeeeee 7 6 Monitoring Self detected Information soeia RE EEEE EEEE EEEE EE 7 stopping Ee 7 8 Configuring Master Subordinative RPDU sssssessssseesssssserrrsssssrrrrrerssssrrrrererrssssrrrreresssssrrrrreersss 7 9 Daisy chain Connection Method 7 10 Radialized Connection Method 8 1d SOttware E E ele EN 9 VI RPDU Software Introduction ccccccceccecceeceeseeeseeseeeceeseeeceeseceeeeseceeeeseceseeaeeeseeeeeaeeeseaeeneeeaees 10 1 Software Overview ous face sensed cussed See dE AEN EE ee Eege Eeer 10 2 Software Function Descnppon 00sec cence nee ne ene eden cence ence eee naee ene eee ene ene ene EEE eniene esas 11 3 Accessing Method i arris cevsed ces ee NENNEN cove cus ENNER seve ede edaled sexe dE ENN EEN VNESENE KEEA NAN E AR Nd 12 4 HTME Interfaces ET 1
11. age such as FW No MAC hardware address storage size and operation time 20 Vertical PDU remote PDU User Manual Click Reset System Settings to reset to come into force and then it will be empty for all settings when logging in again so users need to input manually For example RPDU No and so on 10 HT TP SSL Configuration Information A HTTP Function Configuration HTTP protocol namely hypertext transport protocols is an object oriented protocol in application level HTTP protocol is so simple that operation program of HTTP server is smaller accordingly therefore communication speed is faster RPDU system adopts HTTP protocol to make the system management data communication and controlling more convenient and faster A Users click Web on User Guide Menu to open relative interface B Select Enable on the pull down menu of Server to enable HTTP function configuration C Input HTTP port number in the corresponding input interface of port D Click Apply to submit and save configuration B SSL Function Configuration Secure Socket Layers SSL used to ensure the safety of transport data when users access RPDU remotely SSL Makes the RPDU data system communication safer network management more convenient and safer A Click Enable under the drop down menu of Server to enable SSL function B Click Optional under the pull down menu of Secure Access to enable th
12. al output unit current load total current load temperature amp humidity are higher than preset limited max value For example when any of the above situation happens at output unit Al RPDU Display Board will alarm by displaying A 1 and Alarm Buzzer will ring to alter related administrator 6 Monitoring Self detected Information Turn OUTLET No 1 Button to display then press RESET Button and RPDU Display Board will sequentially displays RPDU Self detected Information for one minute 7 Stopping Present Alarming State When RPDU is alarming Outlet No 1 Button is not available for checking other information It needs to press RESET button to stop Alarm Function for one minute then other information can be checked But it still alarms after one minute unless operation fault is cleared 8 Configuring Master Subordinative RPDU Press RESET button for 10 13 seconds M S Indicator will light to indicate master RPDU Press RESET button for 5 8 seconds M S Indicator will off and it indicate Subordinative RPDU The calculation of time can see the RUN indicator T 2 seconds 9 Daisy chain Connection Method Vertical PDU remote PDU User Manual Please refer the following Diagram and Operation Steps Master subordinative 1 subordinative 2 subordinative 3 subordinative 4 WAN cable lt LAN cable gt the next subordinative 1 Each RPDU has exclusive Serial No different from others which have been appoint
13. ation is load current value exceeded Temperature Humidity value exceeded Smoke appears waterlogging happens or when cabinet door opens output units operate individual output unit fails to work normally sensors outputted or inputted 10 User Management user s authority can be configured 11 Access method can be accessed through web IE Accessing and controlling through Standard Network Management Protocal that is SNMP V1 V2 Accessing and controlling through the console of the commanding form that is Telnet SSH 12 System Support Supporting multi user operation and software updation MI Applicable Range Vertical PDU remote PDU User Manual 1 RPDU series products are specially made for standard and non standard server cabinet network cabinet etc 2 The socket quantity and socket standard of RPDU vertical mounted products can be made according to customer specific needs 3 RPDU series products are in compliance with the requirements of RoHS directive suitable for 110VAC and 220 VAC power supply and able to satisfy different customers requirements in different countries and areas IV Product Diagram and Explanation of next RPDU 1 18 Mounting Hole 2 Display Board display output address and corresponding current value 3 RUN Operation Indicator 4 M S Master Subordinative RPDU Indicator Master RPDU is indicated with lighted M S Indicator 5 OUTLET Nol used for locating s
14. click and choose to open the power controlling interface of target RPDU C Opened Interface will display the name version No and series No of present RPDU For example RPDUV B Series RPDUV B D Opened Interface will also display the name current value power on off state and corresponding control pull down menu of every output unit of target RPDU Users can click and choose ON OFF Reboot under pull down menu of individual unit and then click Apply button to control the output unit Users also can choose ON OFF Reboot under pull down menu of several relevant output units and then click Apply button to control the several output units at the same time E For quickly powering on powering off or rebooting all the output unit of target RPDU users can click and choose ON OFF Reboot under pull down menu of All Outlets and then click Apply F Total Current corresponds with the total current of all output units of RPDU G Total Voltage corresponds with the total voltage of all output units of RPDU H Energy Meter corresponds with the energy of every group of RPDU Fa Total Energy Meter correspond with the total energy of RPDU J It includes five pages As the below table separately No No of every output unit Output Name Name of every output unit 14 Vertical PDU remote PDU User Manual Current Am
15. configured B Input IP address of master RPDU IP address to open RPDU WEB system and then enter Device Configuration interface C Input Ethernet Address of daisy chain in RPDU Address No dialogue interface and configure the names of daisy chained RPDU in RPDU Name dialogue interface D Click Apply button to submit and save configurated information E Click Device Control on User Guide Menu to open RPDU Control Interface then click to choose target RPDU from select device pull down menu and if data information of opened target RPDU can be read successfully and this indicate the RPDU daisy chain connection is correct 2 Daisy chain Configuration A Confirm all the ethernet address of daisy chained RPDUs be exclusive different from each other B Give exclusive name to every single daisy chain RPDU to avoid confusion 6 FAQ and Solutions 1 Input RPDU IP and then press enter but can not see Login Dialogue Interface Solution Firstly configure and confirm RPDU IP and the PC IP connected with RPDU are in the same network segment Ping RPDU IP address to confirm network connection is in normal state 2 Input user name and password in Login Dialogue Interface but can not enter RPDU Web interface Solution Please confirm whether user name and password are correct and submit again 3 Entering into RPDU Web interface but can not read RPDU state Solution open Device Configuration to c
16. dicating the state with LED G Support reset function on individual output unit level and that on output unit group level H Support preseting the current load alarm threshold value of on individual output unit level on output unit group level and on the whole RPDU system level I Support detecting total voltage energy group and total energy J Support controlling the power on off state of individual output unit K Support reading log records and deleting function L Support keeping the original state of output units when reset M Support preseting the temperature humidity alarm threshold value N Support monitoring the state of temperature humidity Smoke water and door open sensors in the RPDU installed cabinet O Support sound e mail and SNMP alarm function 11 Vertical PDU remote PDU User Manual 2 Advanced Function Description A Support checking RPDU version No hardware address and other system information B Support HTTP SSL configuration information C Support Telnet SSH configuration information D Support SNMP network management function E Support updation on software system level F Support updation on hardware system level G Support Adding deleting users configuring users authorities modifying users information and other functions H Support resetting RPDU function I Support system exiting function 3 Accessing Methods 1 IE Internet Explorer Browser Access Method A
17. e unsafe HTTP and SSL encryption HTTP access Select Required only to enable SSL encryption connection interview C Click Apply button to submit and save configuration 11 SNMP Function Configuration RPDU support Simple Network management Protocol SNMP which enables administrator to use SNMP to search network information and control individual output units through network management system RPDU system has SNMP function which includes MIB I and MIB II and support remote power control function A Users click SNMP in User Guide Menu to open corresponding WEB interface B Select Enabled or Disabled in SNMP Agent pull down menu to confirm whether enable SNMP function 21 Vertical PDU remote PDU User Manual C Configure community string and input community string in the Get Community dialogue interface string length should be in the area of 1 24 characters D Configure SNMP calculagraph input one trap calculagraph value in the Error Trap Repeat Time frame trap calculagraph value should be between 1 65535 E Configure trap object input one IP address on Trap Destination dialogue interface and then click Apply button 12 Updation Method Upload Firmware by FTP Upload a new firmware or ROM image into flash A firmware image file must be called image din A ROM image file must be called rom Am sot rom bin or romzip bin Select Image Upload Administra
18. ed before leaving factory and can not be changed 2 Once Master RPDU is appointed and the others will automatically become Subordinative RPDU Up to 10 pieces of RPDU can be connected together 3 Connect one end of attached network line to LINK port of Master RPDU and the other end to SER Port of first Subordinative RPDU and then connect one end of network line to LINK port of first Subordinative RPDU and the other end to the SER Port of second Subordinative RPDU and goes on until all the RPDU 10 pieces at most are connected together 4 Connect one end of attached network line to net port of PC and the other end to NET Port of Master RPDU accessing through IE Details please refers to Software Introduction 10 Radialized Connection Method Please refer the following Diagram and Operation Steps master HUB WAN cable lt LAN cable gt H wx go See men mm mam mag mm e KEE i E p sch 4 Lt l the SER SER SER next subordinative LO m m ELI SER A K sch subordinative 1 subordinative 2 subordinative 3 subordinative 4 subordinative 5 1 Appoint one Master RPDU and the others automatically become Subordinative RPDU Up to 10 pieces of RPDU can be connected together Vertical PDU remote PDU User Manual 2 Connect one end of attached network line to net port of PC and the other end to
19. eshold value temperature humidity value will become red and flash to alarm E When Smoke state appears Smoke sensor value will become red YES and flash to alarm F When cabinet door is opened related door sensor value will become red OPEN and flash to alarm G When waterlogging happens related waterlogging sensor value will become red YES and flash to alarm 15 Vertical PDU remote PDU User Manual H Clicking Refresh button at any time to refresh the state and get updated information 4 RPDU Device Configuration Select Device NPDU1 Refresh SETAE aan NPDU1 status NPDU25 B Er Basic NPDU Control No Output Name Current Amps Output Status ON OFF Control Sensor lt NPDU Configuration 1 Output 1 0 0 e NONE Network 2 Output 2 0 0 KI NONE v Threshold Value 3 Output 3 0 0 e NONE v Alarm settings 4 Output 4 0 0 EN NONE X Alarm Logs 5 Output 5 0 0 D NONE v Ge 6 Output 6 0 0 a NONE gei 7 Output 7 0 0 Li NONE D System Infor DEUS HTTP 8 Output 8 0 0 EI NONE v Telnet SSH 9 Output 9 0 0 e NONE SNMP a 10 Output 10 0 0 H NONE X 7 Software upgrade 11 Output 11 0 0 amp NONE WEEE 12 Output 12 0 0 e NONE Reboot Total Current 0 0 Logout Apply Cancel Global Control All Outlets NONE e Apply Cancel View Voltage and Energy Total Voltage 215V Energy Meter 1 Not found Energy Meter 2 Not found Energy Meter3 Not found Energy Meter 4 N
20. heck whether RPDU address on Address No dialogue interface is correct refresh to read after confirming this address is the same as that of related RPDU 24 Vertical PDU remote PDU User Manual address If not the same please input correct RPDU address on Address No dialogue interface and then click Apply to save and read RPDU state again Vil Operation Steps 1 Horizontally fix RPDU 2 Connect temperature humidity waterlogging Smoke and door sensors correctly 3 Choose connection method according to specific requirements details please refer to chapter Six 4 Connect RPDU plug to AC power source then connect and configure master and subordinative RPDU and finally run IE browser to configure relevant parameter correctly IX Performance amp Technical Parameter Table Performance parameter Technical parameter rated input voltage 125 250VAC 50 60HZ input terminal type IEC60309 industrial standard plug IP44 1 Input cable specification 3x2 5mm 3x6 0mm cable length 2M Max input current 16A 32A socket standard IEC320 C13 C19 output unit quantity 12 16 20 24 Vertically installation 2 Output unit X LED display power on off state of individual output unit replaceable fuse fitting optional output unit safety protection Anti fall protection fitting 25 Vertical PDU remote PDU User Manual
21. inal state of each output unit when RPDU is reset 4 Alarm Threshold Value User Defined Function Preset the min amp max total current load value current load of individual output unit not available for A series and temperature humidity value 5 System Default Alarm Function Alarm when total current load is over preset value or individual output unit current load is over preset value not available for A series or individual Vertical PDU remote PDU User Manual output unit fails to work normally not available for A series or Smoke appears or waterlogging happens or when cabinet door opens 6 Multi alarm Functions Operation Indicator flashes Alarm Buzzer rings on RPDU control panel The current overload value is displayed and flashes on web browser Managing Interface and PC buzzer alarms Automatically send e mail to related administrator SNMP sends alarm information Automatic wireless access sends to administrator 7 Energy Measurement Automatically record total current consumption per unit time 8 Daisy chain Functions By using the methods of series connection or radicalized connection up to 10 pieces of RPDU including the Master RPDU can be connected together to be monitored and managed in front of one control interface 9 Event Log Record Recording and saving alarm information of present RPDU for Tracing and Collecting Attention Log record can be read only by sequence and the inform
22. ion a Click Alarm on User Guide Menu and then click Threshold Value to open relative web interface b Opening the corresponding HTML interface Choosing the daisy chained RPDU under pull down menu of the daisy chained device to enable to set current load alarm threshold value of RPDU c Input Max amp Min temperature humidity value it can t exceed the rating value d This interface detailed information is as following table Name sensor name Current Temperature current temperature sensor value Low limit minimal temperature sensor threshold High limit maximal temperature sensor threshold Current Humidity current humidity sensor value Low limit minimal humidity sensor threshold High limit maximal humidity sensor threshold e Click Apply button to submit and save the configured temperature humidity sensor information C Alarming Method Configuration Three alarming methods sound alarm and e mail alarm SNMP Traps a Configure Sound Alarm Method 19 Vertical PDU remote PDU User Manual Click Enabled Sound Prompt to enable sound alarm function when exceeding alarm threshold value alarm on PC of administrator of RPDU will ring to alarm related administrator Attention the web browser must support audio player b Configure E Mail Alarm Method Click Enabled E mail Prompt to enable e mail alarm function when exceeding alarm threshold value it will automatical
23. ly send e mail to preset e mail address a Setting DNS address on the Network Information Configuration interface b Activing the E mail settings c Setting E mail sever on the Alarm setting interface such as sever POP3 SMTP d Setting the user s name and password of the sender e Setting recipient s address f Setting time interval g Click Test and then press Apply to save Attention there must be network connection when the E mail is automatically sended c Configure SNMP Traps Alarm Method Administator can check the newest state information when RPDU goes wrong And SNMP can record and save unnormal state information Specific description please see No 11 8 Log record When it goes wrong with RPDU log will automatically record and save the unnormal state information and record alarming time and detailed description Specific functions and steps is are follows A Click and choose Alarms Logs under the Main Guide Menu and open WEB interface B Choose the daisy chained RPDU under pull down menu of the daisy chained device to check the log records of each RPDU C Choose First Previous Next to view the log records turning around pages D Choose the form as Txt Excel Web to export the log records E Click Clear all records to delete all log records 9 System Information Users can view all the system configuration information of RPDU through System Information p
24. ot found Energy Meter5 Not found Energy Meter6 Not found Total Energy Meter 126 8 KWH View sensor status Temperature Humidity 1 Temperature 38 C Humidity 42 Temperature Humidity 2 Temperature 30 C Humidity 67 Temperature Humidity 3 Temperature Not found Humidity Not found Door 1 Not found Door 2 Not found Smoke alarm NO The above RPDU Device Configuration Interface is mainly used to configure daisy chained RPDU s device add or modify the daisy chained device s name address interval time for sequential power on individual output unit s name and other information Specific operations are as follows A The corresponding pull down menu of Select Device will display the name of the present selected RPDU B Input the daisy chained RPDU No in the dialogue interfaces RPDU Address No The No is factory settings and exclusive value It can t be the same as other RPDUs No when daisy chained otherwise errors will be found C RPDU name dialogue interface is used to name daisy chained RPDUs For convenient management exclusive name for individual RPDU is recommended D 1 24 dialogue interfaces are used to name individual output unit E Sequence Interval dialogue interface input interval time value 0 255 which is used to check and modify the sequential power of the daisy chained RPDU F Click Apply button to save configured information 16 Vertical PDU remote PDU User Manual 5
25. output units according to the setting time A Users click and choose the Timing Control under the Main Guide Menu and then open the corresponding HTML interface B In the interface users choose the daisy chained RPDU under pull down menu of the daisy chained device to enable to control power on off sequentially of the RPDU C Local time displays the users local time correspondly RPDU Clock corresponds with the RPDU s date and time When the date and time is not the same as users local time users can click the setting button to check the RPDU s clock D The page is divided into 4 lines No Corresponding with the No of every output unit of RPDU Output Name Corresponding with the name of every output unit Corresponding with dialogue interface of the power on ON Timing yy mm dd time interval of every output unit Corresponding with dialogue interface of the power off OFF Timing yy mm dd time interval of every output unit E Users set the power on off time interval of every output unit of RPDU through the tips about time form under the page And then click the Apply button information of Set success comes out and users set it successfully F Choose Repeat setting successfully and then the RPDU will power on off according to the settings on schedule 7 Alarming Function and Configuration Exceeding value alarms includes total individual current load
26. pecific output unit address 1 8 way 6 OUTLET No 2 work with OUTLET No 1 to locate specific output unit address one push adds 8 ways or reduce 8 ports 7 RESET Used when configuring Master Subordinative RPDU and for refreshing RPDU operation state 8 Water Waterlogging Sensor Port 9 Smoke Smoke Sensor Port 10 Port2 Un appointed RS485 port 11 NET Port used for connectting RPDU to RJ45 port of PC HUB router or switcher and thus remotely control is available 12 SER Port used when daisy chain needed SER port connect to LINK port of former RPDU 13 LINK Port used when daisy chain needed LINK port connect to SER port 14 Port1 Port of uploading file for RPDU software Updation 5 Vertical PDU remote PDU User Manual 15 Doorl amp Door2 for connecting with door opening sensor 16 T H1 amp T H2 amp T H3 for connecting with temperature humidity sensor 17 Output Unit Address can carry up to 24 ways Of output unit NEMA 5 20R sockets V Installation Method Vertical Installation VI RPDU Hardware Introduction 1 Powering on amp Self detection Once the circuit is powered on RPDU will firstly self detected Alarm Buzzer will make a sound then LED Operation Indicator on RPDU function modular panel will light Display Board will 8 8 8 sequentially displays 8 8 8 indicating that LED in normal operation state Software Version e g i AbC 1 01 Baud Rate e g 9 600 Serial Number e g dE
27. ps The current load of every output unit The power on off state of every output unit indicates power Output Status ON OFF on indicates power off Control The on off button of the pull down menu of every output unit K Clicking View sensors status will open new interface for checking sensor monitor information of target RPDU 3 Sensor Monitoring Select Device NPDU1 si Refresh Sensor status with NPDU1 Temperature Humidity 1 Temperature 23 C Humidity 27 Temperature Humidity 2 Temperature 25 C Humidity 23 Temperature Humidity 3 Temperature 22 C Humidity 28 Door 1 Door 2 Smoke alarm NO Waterlogging NO Related Page Threshold value The above Sensor Monitoring Interface monitors the state of temperature humidity Smoke waterlogging and door open close of the cabinets in which installed RPDU When the temperature humidity values exceed alarm threshold value temperature humidity value will become red and flash to alarm A Sensor information includes Sensor name temperature humidity value state and relative data of Smoke water door open close B For sensor monitoring information of different RPDU users can select the pull down menu of daisy chained device and then choose every daisy chained RPDU through the interface C When there is no sensor connected or not connected correctly sensor state will be Not found D When the temperature humidity values exceed alarm thr
28. sor network node technologies It a remote intelligent controlling and managing system that is connected RPDU 10 Vertical PDU remote PDU User Manual Network Power Distribution Unit network devices in the cabinet to enable monitoring and controlling through network RPDU administor can monitor control and manage many pieces of electrical and electronic equipments in standard or non standard cabinets all over the world through LAN and WAN And supporting hardware sensor monitoring Temperature Humidity Sensor Door Open Close Sensor Waterogging Sensor and Smoke Sensor It provides very easy and friendly Web operation interface a system supporting mutiple user and it is compatible with various kinds of network connection 2 Software Function Description 1 Basic Function Description A Support IE Internet Explorer browser access method providing friendly operation interface supporting multi user B Support Network Configuration the parameters of IP subnet mask gateway and DNS can modified accordingly C Support remote monitoring controlling and managing through network D Support 10 pieces of RPDU daisy chained or radialized connected together to be centrally configured and managed in front of one operation interface E Support monitoring individual output unit current load and total current load F Support controlling the power on off state on individual output unit level and that on output unit group level and in
29. tor can upload a new version of RPDU system software to RPDU in the updation interface Updation Methods A Click Update in User Guide Menu to open new WEB page B Computer connecting with RPDU directly C Click Browse button to select the updated bin file and then click Upload to upload this file to the RPDU D Click Upload to upload the file to RPDU F After finishing upload must power off RPDU and reboot RPDU to complete the software updation 13 User Management Administrator can view users information and level on the User Management interface And Administrator can delete and edit user s information and authorities Common user user can only operate basic functions of RPDU system A Click User Manage in User Guide Menu to open corresponding WEB Interface B This Interface shows all user information of RPDU system user name user level user authorities detailed operation etc 22 Vertical PDU remote PDU User Manual C Details of user management interface information are as follows User Name User name Level include two level of use Administrator is senior user and the others are common user User Control Rights User authority editing click Edit to enter user authority editing interface click Edit to enter user information editing interface to edit user Action password user lever click Remove button to delete target users
30. ture 0 C 55 C 11 Environment relative humidity 10 90 12 RoHS yes X Quality Guarantee Policy Product Warranty Period is two years counted from the date of the purchase of the product During Warranty Period the seller s obligations for defective products limits to replacement repair on the buyer s place or returning back to factory for maintenance Generally buyers get maintenance free of charge within Warranty Period but certain fee will be charged if Warranty Period expires or for incorrect use The above Quality Guarantee Policy will not apply to below cases 1 Failure operation caused by incorrect or improper maintenance by the buyer 2 Failure operation caused by unauthorized change modification or abuse by the buyer 3 Failure operation due to use outside the stipulated physical environment scope by the buyer Guidelines for Factory Maintenance 1 Please make sure to use protective packaging hard box and note that transit damage is not included in the scope of maintenance 2 Please simply state product problems and operation procedures 27 Vertical PDU remote PDU User Manual 3 Please prepay freight cost and all the relevant customs duties and taxes 4 Please clearly state customer name address and a telephone number that can be reached whenever necessary 28
31. value Max amp Min value of temperature humidity When the current value of individual output unit and temperature humidity value exceed preset alarm threshold value alarm buzzer on RPDU panel will rings to alarm and at the same time relevant current overload value and temperature humidity sensors value will become red and flash to alarm Alarm Manners sound alarm and e mail alarm SNMP Traps A Current Load Alarming Function Configuration a Click Alarm on User Guide Menu and then click Threshold Value to open relative HTML interface 18 Vertical PDU remote PDU User Manual b Open the corresponding HTML interface Choose the daisy chained RPDU under pull down menu of the daisy chained device to enable to set current load alarm threshold value of RPDU c Input Max amp Min current load value it can t exceed the rating value d Interface detailed information is included in the below table NO Individual output unit number Output unit Name Individual output unit name Current Amps Individual output unit current load Overload Individual output unit max current load Low limit Individual output unit minimal current load value High limit Individual output unit maximal current load value e Total Current corresponds with the total current load alarm threshold value of RPDU f Click Apply button to submit and set successfully B Environment Alarming Function Configurat