Home
User manual - Wassermann Dental
Contents
1. its intended application Servicing and repairs should be carried out only by authorised specialists bi Make sure that the equipment is connected to the correct power source SES WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 1 4 Your user manual Configuring and operating this equipment requires precise knowledge and observance of the instructions in this user manual The equipment is designed only for its intended application 1 5 Responsibility for operation and damage The responsibility for operating the unit lies exclusively with the owner or user if the said unit is incorrectly serviced maintained or altered by persons not employed by an authorized dealer or if the unit is used in a manner contrary to its specified purpose The unit must be maintained and operated in accordance with this user manual Wassermann Dental Maschinen GmbH is not responsible for damage arising from the non observance of these instructions Guarantee and responsibility provisions contained in the sales and supply conditions of Wassermann Dental Maschinen GmbH are not extended by these instructions Product responsibility lapses if the equipment is altered by bi unauthorised third parties or if non original parts are installed Use only original WASSERMANN replacement parts 1 6 Authorised users The owner of the equipment must ensure that any users have been provided with the user manual and that they have read and understo
2. AS Hessen eier 4 2 Care and MAINTENANCE cciececcccee cec cence ndweccwscirendecdvencwecdvendveccveccwactweccuencueces 5 en NR NU E 5 2 2 A E 5 3 USE e ANON emu Hmm RE 6 4 Before Vou start aacra eaa bod ee LER FER e EE Ce ERR Fe ER LER RF Fe d 6 43 UNPACKING TRANSPORT anne 6 BE Eh e E E E ee A N 7 4 3 GEREENT 7 5 Installing the brush spindles uuuu0000000000000nnnnn nn nn nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 7 G SUPE UP E 8 T Troubleshooting REN 8 Fol TECHNICAL yy MEE EP 9 7 2 ACCESSORIES AND SPARE PARTS nn geseet du ex ea Een dU nn id 9 HS JBEBAIBSG ooi metit tte toten c DEI ts 10 CEA S ICT IC MTM 10 9 EC CONFORMITY CERTIFICATE eeeeeeeeeneee nennen nennen nennt nnne 11 E WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 1 For your safety 1 1 Correct use of this product This polisher is used for polishing dental appliances Its integrated suction system guarantees optimum performance 1 2 Safety symbols used in this manual Warning This is a warning of risk situations and dangers Failure to observe this warning could be life threatening These warnings must be observed il Information This symbol draws your attention to specific features which must be observed 1 3 Safety guidelines Configuring and operating this equipment requires precise knowledge and observance of the instructions in this user manual The equipment is designed only for
3. User manual Polisher WP EX 3000 with speed regulator Fig WP EX 3000 C WASSERMANN DENTAL MASCHINEN GMBH is WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor Dear customer Thank you for choosing a product from the Wassermann range Wassermann dental equipment incorporates the highest standards of quality and the latest technology In order to enjoy maximum performance and years of trouble free operation please read this user manual carefully before you start work and operate the unit according to the recommended guidelines Please ensure that all personnel operating the equipment have read and understood this user manual Keep this user manual on hand for ready reference Company address Wassermann Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Germany Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 e mail info wassermann dental com URL http www wassermann dental com s WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor lt 2 TL ot MOIEN nuniiseida condis iiis esrb inekhdet use vbdwt boniblsdUde idet obs bfEie ie oor dedi Mir 3 ld CORRECT USE OF THIS PRODUCT ces cuoc ee ai eo cob ren decid ote 3 1 2 SAFETY SYMBOLS USED IN THIS MANUALE 3 159 SABEN GUIDELINES SH BEREIT n afta RM at 3 1 4 YOUR USER MANUAL EE 4 1 5 RESPONSIBILITY FOR OPERATION AND DAMAGE eene enne 4 1 6 ZAUTHORISED SERS
4. and a powerful suction unit Shaft ends have 9mm long standard tapers for mounting the brush spindles The polishing troughs are made of soft rubber and are easily removable despite the screw in suction feet 4 Before you start 4 1 Unpacking Transport Open the cartons remove the packing materials and carefully lift out the instrument and accessories Check that the accessories are correct Place the instrument on a firm level surface When transporting the instrument use appropriate packing materials to avoid accidental damage il Locate the operating instructions and read them carefully When unpacking it is important to identify any accidental transport damage If necessary draw up an immediate status report SC WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 4 2 Contents 146994 152022 152025 592012 610015 WP EX 3000 polisher Right brush spindle Left brush spindle Cable with right angle plug 2 x microfine dust filter bag installed 4 3 Location storage The polisher location is very important when it comes to workplace safety even if itis only to be set up there for a short period The room should be dry well ventilated and vibration free An even temperature and wooden supports also help The polisher should not be stored out of doors 5 Installing the brush spindles The nuts must first be removed before you install the brush spindles Use a cloth to ensure t
5. aused by improper use external mechanical causes transport damage or interference with the unit by unauthorized persons Ze WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 9 EC CONFORMITY CERTIFICATE in accordance with 73 23 EWG low voltage guidelines modified by 93 68 EWG and 89 336 EWG EMV guidelines and 89 392 EWG Machinery guidelines with modifications Manufacturer WASSERMANN Product description Polisher for dental Dental Maschinen GmbH applications Rudorffweg 15 17 D 21031 Hamburg Model WP EX 3000 polisher 146994 Applicable EN 61010 1 1993 A2 1995 standards EN 60335 2 54 03 97 EN 50081 1 EN 50082 1 DIN 45635 1 Hiermit wird bestatigt dass die oben bezeichnete Maschine den genannten EG Richtlinien entspricht Diese Erklarung wird ungiltig falls die Maschine ohne unsere Zustimmung verandert wird This is to confirm that the above mentioned machine complies with the described EC rules This declaration becomes invalid if the machine is modified without our approval Cette machine est conforme aux normes en vigueur de la Communit Europ ene Cet avis est nul et non avenant si cette machine est modifi e sans notre accord Esta maquina anteriormente mencionada cumple con los limites requeridos por el reglamento EC Ahora bien esta declaraci n quedar invalidada en caso de realizar modificaciones al aparato sin nuestra aprobaci n Hiermee wordt bevestigd dat bovengenoemde machine voldo
6. et aan de voorgeschreven EU normen Deze verklaring verliest geldigheid als er zonder onze uitdrukkelijke toestemming wijzigen aan de machine worden aangebracht Place date Hamburg 10 April 2003 Company stamp Signature Mid M RE Wilfried Wassermann Managing Director D L Ih WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor WASSERMANN DENTAL MASCHINEN WASSERMANN Dental Maschinen GmbH Rudorffweg 15 17 D 21031 Hamburg Tel 49 0 40 730 926 0 Fax 49 0 40 730 37 24 e mail info wassermann dental com Internet http www wassermann dental com
7. hat the shaft ends are free of grease and then remount the nuts Use compressed air to remove any dust and dirt from the brush spindles Then install the spindles as marked L z left and R z right Fix the spindles in place by tapping lightly on the tip of the taper using a hammer and a plastic block Do not use force as this could damage the bearings and void the warranty When the motor is on the spindles must run true If they do not repeat the installation process s WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor The instrument must be at room temperature before you start it Connect the polisher to the power supply Turn on main switch green rocker switch Use the selector to set the motor speed The speed can even be adjusted during operation using the arrow keys Yellow key Blower ON OFF Use green key for Start Stop Dre DE E e 7 Troubleshooting Correcting Errors Fault Likely cause Likely solution Spindles do not stay in Spindles too Use light hammer taps to fix spindles in place loose place Spindles cannot be Spindles located Contact our Service department undone too firmly on tapers Little to no suction Filter bag full Replace filter bag Bearing noise Faulty bearing Contact our Service department If the above recommendations do not solve the problem contact your dental depot or our Service department u WASSERMANN DENTAL MASCHINEN Die Bas
8. is f r Ihr Labor 7 1 Technical data Voltage 230V 50Hz Power consumption 3 7 A 850W Output 500 W Suction capacity 970 m2 h Weight 51 kg Width 645 mm Depth 545 mm Height 475 mm il Polisher noise emission lt 70db A il We reserve the right to make technical changes 7 2 Accessories and spare parts Accessories 155022 Right brush spindle 155025 Left brush spindle 611011 Spare filter bag 1 set 2 pieces Spare parts 152022 Right brush spindle 152025 Left brush spindle 152043 125 mm right brush spindle 152044 125 mm left brush spindle 152049 1 6 mm drill chuck 152056 Right ceramic holder 152057 Left ceramic holder Ss WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 7 3 Repairs Servicing or repairs to the unit must only be carried out by trained technicians Only original Wassermann spares are to be used Responsibility for the product is voided if altered by unauthorised persons or if inappropriate components are installed 8 Warranty The warranty period for our equipment is 12 months If faults occur within the warranty period contact your dental depot or get in touch directly with our Service department The WP EX 3000 polisher should only be operated in perfect condition If faults occur which could harm operators or third parties the unit should not be used until it has been fixed The warranty does not cover damage c
9. od its contents before operating the equipment D Ensure that this user manual is accessible at all times and has been read and understood CR WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 2 Care and maintenance 2 1 Maintenance Always disconnect the power cable before undertaking N cleaning or maintenance The model plate must always be legible and should not be removed The equipment should be cleaned at regular intervals to ensure trouble free operation It requires only normal cleaning sponge damp cloth mild detergent Do not use chemical additives Always ensure that the nuts in the holes for the brush spindles remain clean Be especially careful when polishing with pumice stone When undoing the nuts remember that the left side has a right hand thread and the right side a left hand thread 2 2 Care Remove external dirt from time to time with some form of cold il cleaner Use only cold cleaners to avoid damaging the paintwork or removing the lettering Recommended A151 universal cleaner ups WASSERMANN DENTAL MASCHINEN Die Basis f r Ihr Labor 3 Use Application The WP EX 3000 polisher has a well tried efficient maintenance free single phase AC motor induction motor which runs at speeds adjustable from 750 rpm to 1500 rpm in 250 steps and from 1500 rpm to 6000 rpm in 500 steps It has low noise completely maintenance free bearings The WP EX 3000 also comes with a light
Download Pdf Manuals
Related Search
Related Contents
Manuel d`instruction Perm OM 11-02 ABUS FU8220 siren Elkay ERS1-1D User's Manual Hasselblad 203 FE Instruction Manual PB Heat Gas/Oil Boilers Boiler User Manual LOGOLINE 500 B 70.6001.0 Betriebsanleitung Copyright © All rights reserved.
Failed to retrieve file