Home

AX022310

image

Contents

1. Global Electronic Solutions TECHNICAL DATASHEET TDAX022310 Dual Plug In Valve Controller SAE J1939 2 2 5A Outputs Programmable P N AX022310 Distribute your control functions directly onto the valve Features e Configurable for 1 or 2 outputs to drive hydraulic valves proportional 0 2 5A or on off 2 5A e Superimposed dither e Independent ramps 0 10 seconds to suit the application e Fully protected outputs e 12V 24Vdc nominal input power e 1 CAN port SAE J1939 for integration into the machine s CAN bus network e Rugged IP67 packaging e Integrated connectors to minimize wiring and reduce installation time e Compact Plug in style for valve coils having the molded in Deutsch IPD DT04 2P electrical connectors e User programmable functionality Axiomatic Electronic Assistant Applications The hydraulic valve controller is designed to meet the rugged demands of mobile equipment oil and gas equipment and heavy duty industrial machine applications It can be used for distributed control of the following e Flow or pressure control of single solenoid hydraulic valves e Control of dual solenoid hydraulic valves e Control of hydraulic fan drives e Transmission control for accurate low speed control of vehicles Ordering Part Numbers Dual Valve Controller SAE J1939 Plug In AX022310 Electronic Assistant AX070502 Mating Plug Kit AX070119 Description The Dual Output Plug In Valve Controller wit
2. ch IPD 19 5 mm Specifications are indicative and subject to change Actual performance will vary depending on the application and operating conditions Users should satisfy themselves that the product is suitable for use in the intended application All our products carry a limited warranty against defects in material and workmanship Please refer to our Warranty Application Approvals Limitations and Return Materials Process as described on www axiomatic com service html Form TDAX022310 01 23 15 TDAX022310
3. h SAE J1939 is designed for extremely versatile control of the two proportional outputs to directly drive coils or other loads from the machine s CAN bus Its flexible circuit design gives the user a wide range of configurable output types The sophisticated control algorithms allow the user to program the controller for a wide range of applications without the need for custom software The two universal outputs can be setup to drive proportional current up to 2 5A each hotshot digital current 2 5A proportional voltage up to supply proportional PWM or straight on off digital loads Both outputs are high side driven sourcing outputs A programmable controller the user can configure it for their application using the Axiomatic Electronic Assistant Its sophisticated control algorithms allow for open or closed loop drive of the proportional outputs It is integrated into the machine s CAN network of controllers All outputs and logical function blocks on the unit are inherently independent from one another but can be programmed to interact in a large number of ways In Europe In North America Axiomatic Technologies Oy Axiomatic Technologies Corporation H yt m ntie 6 5915 Wallace Street 33880 LEMPAALA Finland Mississauga ON Canada L4Z 1Z8 Tel 358 3 3595 600 Tel 1 905 602 9270 Fax 358 3 3595 660 Fax 1 905 602 9279 www axiomatic fi www axiomatic com Technical Specifications Power Supply Input Power Supply Input No
4. les and Termination Molded Enclosure integral connectors Polyester 15 glass Silicone seals 3 037 x 1 44 x 1 53 inches 77 1 x 36 6 x 38 8 mm L x W x H including integral connectors IP67 rating for the product assembly Random Vibration for vibration isolated cab mount components 16 hours axis 4 41 6 79 Grms 5 Hz 2000 Hz Modified Kurtosis 9 3 Parts of SAE J1445 MIL STD 202 IEC 60068 2 64 0 15 Ibs 0 068 kg Temperature Rating Connectors Electrical Pinout TDAX022310 Operating 40 to 85 C 40 to 185 F Storage 50 to 105 C 58 to 221 F 6 pin Integral Connector Deutsch IPD p n DT04 6P This plug mates to Deutsch IPD p n DT06 6S A mating plug kit is available P N AX070119 2 pin Integral Connector Deutsch IPD p n DT06 2S mates to valve coil with integral DT04 2P Connector not supplied _ L p a o ie 5 F mm hy r ks t j Wires should be of the appropriate gauge to meet requirements of applicable electrical codes and suit the specifications of the connector s Pin Description Notes gt S O 6 Solenoid Be Pin Description Notes o O Dimensional Drawing 2 257 in 780 in 57 3 mm 19 8 mm 1 660 in 1 575 in i 1 000 in 40 0 mm 1 441 in 25 4 mm 36 6 mm 2 132 in 54 2 mm 3 037 in molded in DT06 2S Deutsch IPD 879 in 1 526 in 22 3 mm 38 8 mm molded in DT04 6P Deuts
5. minal 12 24Vdc nominal 9 36 Vdc power supply range Protection Surge protection is provided Reverse polarity protection is provided Overvoltage protection up to 38V is provided Undervoltage hardware and software shutdown at 7 5V is provided Inputs 1 CAN port protocol SAE J1939 Outputs Output Type Two independent software controlled outputs User selectable output functions Half bridge outputs current sensing grounded load High side switch sourcing output 0 2 5A High Frequency Drive 25 kHz Refer to Figure 2 0 De rating Curve Output Functions User selectable from the following Proportional Current mA Proportional Voltage V Average output is based on power supply PWM Duty Cycle Configurable from 1 Hz to 25 kHz only if no current output types are selected Otherwise the default of 25 kHz is used Digital On Off Load supply voltage must not draw more than 2 5A gt Hotshot On Off Current PID Loop Factory calibrated Output Resolution Output Current mode 1mA resolution 2 full scale error and Accuracy Output Voltage mode 0 1V resolution 3 full scale error Output PWM D C mode 0 1 resolution 1 full scale error Dither 50 to 400 Hz 0 to 500 mA 0 20 of I max Both outputs use the same dither frequency Ramp Times Independent 0 10 seconds max to min Protection for Output Fully protected against short circuit to ground and short circuit to power supply rail Grounded shor
6. t circuit protection will engage at 4 5A 0 5A Unit will fail safe in the case of a short circuit condition and is self recovering when the short is removed Independence Fully independent Output GND Reference Two are provided De rating Curve for AX02231x Output Current vs Ambient Temperature 0 0 O N ui 32Vin 24Vin fr 12Vin gt 9Vin N O Ambient Temperature 2C oO uw Output Current mA Figure 2 0 De rating Curve based on both outputs on TDAX022310 2 General Specifications Quiescent Current 16 41 mA at 12 V Typical 11 74 mA at 24 V Typical STM32 32 bit 128 Kbyte program memory Control Logic User programmable functionality Refer to the User Manual for details Reflashing over CAN Provided Per SAE J1939 standard using Electronic Assistant 29 bit IDs 250 kbps baud rate 1 CAN port protocol SAE J1939 User Interface Packaging User configuration and diagnostics are provided with the Axiomatic Electronic Assistant p n AX070502 The Axiomatic Service Tool is a Windows based graphical user interface that allows easy configuration of the controller setpoints Set up of SAE J1939 Controller on a CAN Network Other CAN Modules and Termination Axiomatic Electronic Assistant Axiomatic Controller with CAN SAE J1939 CAN bus USB Cable Axiomatic Controller with CAN Axiomatic USB CAN AX070501 Axiomatic Controller Computer with CAN Other CAN Modu

Download Pdf Manuals