1. CopE 39 FAMILY disables the family O Read the desired family code Q Read a check digit selection CHECK DIGIT TABLE Standard Code 39 no check digit control s check digit control Full ASCII Code 39 and transmission ax MN check digit control without transmission The pharmaceutical codes below are part of the Code 39 family but have no check digit selections Code CIP39 French pharmaceutical code Code 32 Italian pharmaceutical code 73 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VA CODE SELECTION VAN CODE LENGTH optional The code length selection is valid for the entire Code 39 family Read the code 4 numbers for the code length where set code length First 2 digits minimum code length Second 2 digits maximum code length The maximum code length is 99 characters The minimum code length must always be less than or equal to the maximum Examples 0199 variable from 1 to 99 digits in the code 1010 10 digit code length only 74 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration CODE SELECTION CopE 128 FAMILY disables the family D Read the desired family code C
2. 11 USB PARAMETERS Handshaking Ack Nack Protocol Inter character Delay Rx Timeout Serial Trigger Lock Keyboard Nationality Inter character Delay Inter code Delay u u Control Character Emulation u 18 RS232 PARAMETERS 19 Baud Rate Stop Bits Pla dshaki Qu a aaa qaa Ack Nack Protocol neesseessersssessssesseveseersserssersssressreseressersssernssenserssersssesssesssseesserssersee Inter character Delay Rx Timeout1 Serial Trigger LOCK WEDGE PARAMETERS Keyboard Nationality u U u Caps LOCKa amp s dd Caps Lock Auto Recognition IBM AT compatible only Num koga Inter character Delay Inter code Delay oreste reete etre cipe eae Control Character Emulation eee u uuu uuu Keyboard Setting PEN EMULATION Operating Mode Minimum Output 35 Conversion to Code 39 u 36 Overflow Output Level Idle Level Inter Block Delay 38 Delfi TECHNOLOGIES DATA WI v
3. OR match character I 13 Read the match character from the HEX table Range of characters 01 FE OR field length 157 Read two numbers the range 01 to 99 to define the field length OR this is the last field variable length III AND Field 3 Terminators no field terminators 1 field terminator 2 field terminators Read the field terminator character s from the HEX table Valid range of characters for all readers 01 FE For readers using Wedge interface all values from 9C to FE send the Space character 96 Delfi TECHNOLOGIES Exit and Save Configuration ADVANCED FORMATTING DEFINE FIELD 4 BY EITHER field separator I P Read the field separator character from the HEX table Range of characters 01 FE discard separator include separator OR match character MP Read the match character from the HEX table Range of characters 01 FE OR field length MP Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length III AND Field 4 Terminators no field terminators 1 field terminator 2 field te
4. For readers using Wedge interface all values from 9C to FE send the Space character DEFINE FIELD 2 BY 94 Delfi TECHNOLOGIES Exit and Save Configuration ADVANCED FORMATTING Il II EITHER field separator I Qm Read the field separator character from the HEX table Range of characters 01 FE discard separator include separator OR match character Qm Read the match character from the HEX table Range of characters 01 FE OR field length 157 Read two numbers the range 01 to 99 to define the field length OR this is the last field variable length i III AND Field 2 Terminators no field terminators 1 field terminator 2 field terminators Read the field terminator character s from the HEX table Valid range of characters for all readers 01 FE For readers using Wedge interface all values from 9C to FE send the Space character DEFINE FIELD 3 BY EITHER acacia 95 Delfi TECHNOLOGIES Exit and Save Configuration ADVANCED FORMATTING II field separator NP Read the field separator character from the HEX table Range of characters 01 FE discard separator include separator
5. end Format 4 definition 102 Enter Configuration enable enable enable enable ADVANCED FORMATTING Delfi TECHNOLOGIES Exit and Save Configuration Enable Advanced Format no Advanced Formats enabled Advanced Format 1 disable Advanced Format 2 disable Advanced Format 3 disable Advanced Format 4 disable No Match Result clear data no transmission transmit data using standard format 103 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration ADvaNceD Formattinc FN This selection determines the action to be taken when codes read do not conform to the advanced format requisites no match e Codesnot matching can be ignored cleared from memory and not transmitted e Codes not matching be transmitted using the Standard formatting Headers Code Length Code ID Terminators 104 Delfi TECHNOLOGIES REFERENCES 4 REFERENCES 4 1 05 AND RS232 PARAMETERS 4 1 1 Handshaking Hardware handshaking RTS CTS The RTS line is activated by the decoder before transmitting a character Transmission is possible only if the CTS line controlled by the Host is active Signals at EIA levels RIS TX _ L L Transmitted data Transmitted data CTS Host busy
6. delay disabled CONTROL CHARACTER EMULATION CTRL Shift Key CTRL Key 30 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VALLA WEDGE VAN KEYBOARD SETTING ALPHANUMERIC KEYBOARD SETTING The reader can be used with terminals or PCs with various keyboard types and nationalities through a simple keyboard setting procedure The type of computer or terminal must be selected before activating the keyboard setting command Keyboard setting consists of communicating to the reader how to send data corresponding to the keyboard used in the application The keys must be set in a specific order Press and release a key to set it Some characters may require more than one key pressed simultaneously during normal use refer to the manual of your PC or terminal for keyboard use The exact sequence must be indicated to the reader in this case pressing and releasing the different keys Example If one has to press the Shift and 4 keys simultaneously on the keyboard to transmit the character to the video to set the press and release Shift then press and release 4 Each pressed and released key must generate an acoustic signal on the reader otherwise repress the key Never press more than one key at the same time even if this corresponds to the normal use of your keyboard Press Backspace to correct a wrong key entry In th
7. CODE LENGTH TX code length not transmitted code length transmitted in variable digit format code length transmitted in fixed 4 digit format The code length is transmitted in the message after the Headers and Code Identifier characters The code length is calculated after performing any field adjustment operations 48 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration DATA FORMAT CHARACTER REPLACEMENT disable character replacement This parameter allows up to three characters to be replaced from the barcode read These substitutions are stored in memory To define each character replacement Read one of the following character replacement codes first character replacement second character replacement third character replacement From the Code Identifier Table in Appendix B read the Code Identifier for the desired code family 0 character replacement will be effective for all code families From the Hex Numeric Table read two characters corresponding to the Hex value 00 FE which identifies the character to be replaced From the Hex Numeric Table read two characters corresponding to the Hex value 00 FE which identifies the new character to replace FF the character to be replaced will be substituted wi
8. Rx TIMEOUT timeout control in reception from Host Read 2 numbers from the table where 00 TIMEOUT disabled 01 99 TIMEOUT from 1 to 9 9 seconds rx timeout 5 seconds See par 4 1 4 for details SERIAL TRIGGER LOCK disabled enable and select characters TANT Read 2 characters from the Hex Numeric table in the range 00 FE where First Character enables device trigger Second Character inhibits device trigger until the first character is received again 15 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VALLA USB KBD VAN KEYBOARD NATIONALITY Not Available for USB KBD ALT MODE Interface This parameter default value is restored through the Interface Selection code and not Restore Default Belgian English French German Italian Japanese Spanish Swedish USA FIFO disable enable See par 4 1 3 for details 16 Delfi TECHNOLOGIES Exit and Save Configuration Enter Configuration VETA USB KBD INTER CHARACTER DELAY delay between characters transmitted to Host Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 milliseconds delay disabled INTER CODE DELAY delay between codes transmitted to Hos
9. no check digit control Type C check digit control check digit transmitted Type C check digit control check digit not transmitted Type K check digit control check digit transmitted Type K check digit control check digit not transmitted C and K check digit control check digits transmitted C and Type K check digit control check digits not transmitted 83 TECHNOLOGIES Enter Configuration Exit and Save Configuration CODE SELECTION DALI CODE 16K disables the code Code 16K To read stacked codes simply move the reader over the code so that each line of the code is scanned CODE 49 disables the code Code 49 To read stacked codes simply move the reader over the code so that each line of the code is scanned 84 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration CODE SELECTION RSS CODES disables the family DISABLE CODE ENABLE CODE disable RSS Expanded Linear and Stacked enable RSS Expanded Linear and Stacked disable RSS Limited enable RSS Limited disable RSS 14 Linear and Stacked enable RSS 14 Linear and Stacked read
10. 4 5 DECODING PARAMETERS These parameters are intended to enhance the decoding capability of the reader for particular applications Used incorrectly they can degrade the reading performance or increase the possibility of a decoding error CAUTION 114 Delfi TECHNOLOGIES REFERENCES 4 5 1 Ink Spread The ink spread parameter allows the decoding of codes which are not perfectly printed because the page texture tends to absorb the ink 4 5 2 Overflow Control The overflow control parameter can be disabled when decoding codes printed on small surfaces which don t allow the use of an overflow space This command does not effect code families 2 5 Code 128 and Code 93 4 5 3 Interdigit Control The interdigit control parameter verifies the interdigit spacing for code families Code 39 and Codabar 115 Delfi TECHNOLOGIES DELFISCAN C80 4 6 CONFIGURATION EDITING COMMANDS The following commands carry out their specific function and then exit the configuration environment Command Description Restore system default configuration see the relative Quick Reference Manual for default settings Transmit the Software release This command is not effective with the Pen emulation interface Transmit the device configuration ASCII format This command is not effective with the Pen emulation interface 116 Delfi TECHNOLOGIES REFERENCES 4
11. TECHNOLOGIES REFERENCES 4 9 FIRMWARE UPGRADES Device firmware upgrades can be performed using the DL Sm rtSet external Downloader utility tool from your PC either through RS232 or USB communications The procedure for downloading is described in the DL Sm rtSet User s Manual and in the Help window A special case occurs when using USB communications to upgrade devices without button trigger Procedure For devices WITHOUT button trigger Launch the Downloader tool from the DL Sm rtSet folder on your PC Connect the device to the PC via USB interface Read the code given below to emulate the trigger press Trigger Press The device will automatically be reset Proceed with the firmware upgrade see the DL Sm rtSet User s Manual for details 119 Delfi DELFISCAN C80 A HOST CONFIGURATION STRINGS In this section we provide a description of how to modify the device configuration using serial strings sent from the Host This method requires either the RS232 or USB COM interface The device configuration can be changed by receiving commands from the Host through the serial interface When this method is used the programming sequence format is the following Command CR Carriage return character 0D Hex EL and Save configuration Character sequence in following tables Enter configu ration environment Example Multiple command programming sequence Action
12. match code length Read the above code two numbers the range 01 to 99 for the exact code length OR any code length 91 Delfi TECHNOLOGIES Exit and Save Configuration ADVANCED FORMATTING 4 Match with Predefined Characters no match match with 1 character match with a 2 character string match with a 3 character string match with a 4 character string EF After selecting the predefined match code read the character s from the HEX table Range of characters 01 FE Example Match code with the 2 character predefined string Match with a 2 character string ved position of first character in predefined string 1 HI Read the above code two numbers in the range 01 to 99 representing the character position in the code where the first character of the predefined string must be found Read 00 if the match string can be found in any character position 92 Delfi TECHNOLOGIES Exit and Save Configuration ADVANCED FORMATTING II Divide Code into Fields divide code into fields Read one number in the range 1 to 5 to divide the code into fields 6 Define Code Fields define code fields Each code field length can be set by either a defining a field separator character to be found in the code itself In this case you can ch
13. For all systems the correct USB driver for the default USB KBD interface is included in the Host Operating System and will either be loaded automatically or will be suggested by the O S and should therefore be selected from the dialog box the first time only If the Host supplies sufficient power to the reader the start up phase ends correctly the LED stops blinking and the reader emits the beep OK signal If the Host does not supply sufficient power to the reader a dialog box will appear on the Host and the reader will be blocked LED continues blinking In this case disconnect the USB device cable at the Host LED stops blinking connect and power up an external supply to the USB device cable then reconnect the USB device cable to the Host and close the dialog box The reader emits the beep OK signal You can now read codes At this point you can read the USB interface configuration code according to your application Load drivers from the O S if requested When configuring the USB COM interface the relevant files and drivers must be installed from the USB Device Installation software which can be downloaded from the web site http www delfi com The reader is ready DELFISCAN C80 FirstStart Up Connect deviceto LEDblinks Host with USB cable ka Load drivers ifrequested Does a dialog Disconnect reader at box appear LED off Host asking whether Bus poweris fficient7 Connect extemal powersupply to cab
14. GO AIMING SYSTEM 1 e Read the Enter Configuration code ONCE available at the top of each page 2 e Read configuration codes from the desired groups Read the code and follow the procedure given Default value 3 Read the Exit and Save Configuration code ONCE available at the top of each page 54 Delfi TECHNOLOGIES HAND HELD OPERATION hardware trigger O software trigger HII always on automatic hardware trigger ready default value for devices with trigger default value for devices without trigger only for CCD readers with trigger only for CCD readers For Automatic Hand Held or Stand Operation the Safety Time parameter is forced to no code consecutive reading 00 See par 4 4 1 for details STAND OPERATION ONLY Devices with Stand Recognition Beep hardware trigger software trigger always on automatic See par 4 4 1 for details 55 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VE READING PARAMETERS VAN HARDWARE TRIGGER SIGNAL ONLY Devices with Button Trigger trigger active level trigger active pulse See par 4 4 2 for details TRIGGER OFF TIMEOUT ONLY Devices with Button Trigger trigger off timeout Read 2 numbers the rang
15. CK99 CL00 CL99 Serial Trigger Lock CRO CR1ab Keyboard nationality Belgian FJ7 not for USB KBD ALT MODE English FJ4 French FJ2 German FJ3 Italian FJ1 Spanish FJ6 FIFO Delays Control Character Emulation CTRL Shift Key 7 Foo Cre Key For 4 a Hex value of the ASCII character from 00 to FE enabling the device trigger b Hex value of the ASCII character from 00 to FE disabling the device trigger Delfi TECHNOLOGIES HOST CONFIGURATION STRINGS DESCRIPTION Baud rate STRING CD1 CD2 CD3 CD4 CD5 CD6 CD7 CD8 CC0 CC1 CC2 CA0 CA1 A2 w e Data bits Stop bits a Handshaking disable RTS CTS XON XOFF RTS always ON ACK NACK Protocol disable enable FIFO disable C enable EC1 Serial Trigger Lock m m m Q NI m a Hex value of the ASCII character from 00 to FE enabling the device trigger b Hex value of the ASCII character from 00 to FE disabling the device trigger 123 Delfi TECHNOLOGIES DELFISCAN C80 Gate gt gt gt y Keyboard nationality Belgian o 2 Ei Fenn es mn em Spanish pe Swedish ms Ha C Japanese EMATcompatibleonly Caps Lock aplokON mi mo Caps Lock Auto Recognition dube mo IBM AT compatible only enable mm Num Lock STE Control Character Emulation CTRL Shift Key Fo Ctrl Key
16. Code Identifier etre s ahua ER RR M saa aa RE RR Custom Code Identifier T ermi at ry a S Naads Special Keys Field Adjustment Field Adjustment Character Code Length Tx Character Replacement POWER ei 51 Sep 52 Sleep State USB 5 5 52 Enter Sleep Timeout Sandes READING PARAMETERS 54 Hand Held Operation isaserasereseeessersseerssersseessersserssersssessseessereseeesserssersssrenssessersseens Stand Operation uumnasenersqnedinkinniieitui dradd Hardware Trigger Signal Trigger off TimeoOUt uci censeat ciet cao e ig Hr Reads per Cycle SEMSVANDICS Beeper Length Good Read Spot Duration Stand Recognition Automatic Operation Aiming Light Alming DECODING PARAMETERS Ink Spread eee Overflow Control Interdigit Control Decoding Safety Puzzle 50 Plessey Telepen Dealer a as
17. enabe o Br Aiming System Bo 300ms 500ms i sec 127 Delfi TECHNOLOGIES DELFISCAN C80 DECODING PARAMETERS Ink spread disable Ao fenable Overflow control diable Aw fenable Interdigit control disable jenble Av Decoding Safety oneread EDO woreads hreereads ffourreads PuzzleSolver disable Au enable CODE SELECTION DESCRIPTION STRING DISABLE ALL FAMILY CODES AZ0 EAN UPC disable EAN UPC family AA0 EAN 8 EAN 13 UPC A UPC E without ADD ON with ADD ON with and without ADD ON EAN 8 EAN 13 without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5 UPC A UPC E without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5 EAN 8 check digit transmission disable EAN 13 check digit transmission disable UPC A check digit transmission disable UPC E check digit transmission disable conversions UPCEto UPCA UPCEto EAN 13 UPCA to EAN 13 EAN 8 to EAN 13 Delfi lp TECHNOLOGIES HOST CONFIGURATION STRINGS CODE SELECTION continued DESCRIPTION STRING ISBN Conversion codes enable ISBN APT enable ISSN AP enable ISBN and ISSN AP3 Code 39 disable Code 39 family Standard nochekdgicuo check digit controland Wansmission check digit control without transmission ABI3 F
18. s L Carriage return character 0D Hex Exit and save new configuration Matrix 2 5 3 bars no check digit variable length code from 1 to 32 characters Beepertone1 Beeper low intensity Enter configuration environment Each configuration parameter setting removes the condition previously active for that parameter The device buffer can contain about 400 characters If your programming string goes over this value you must split it into separate groups and send each group dfter a delay of at least 3 seconds to give the reader time to empty the buffer and interpret the commands SERIAL CONFIGURATION STRINGS TECHNOLOGIES Delfi TECHNOLOGIES HOST CONFIGURATION STRINGS ENTER EXIT CONFIGURATION COMMANDS DESCRIPTION STRING Enter Configuration Exit and Save Configuration Restore Default Transmit Software Release not for PEN emulation Transmit Configuration not for PEN emulation INTERFACE SELECTION DESCRIPTION STRING USB USB KBD uno USB KBD ALT MODE uao USB KBD APPLE uno USB COM uao USB IBM Table Top USB IBM Hand Held uan RS232 Standard ICL Mode Fujitsu Nixdorf Mode A WEDGE Keyboard Type for IBM Terminals 31xx typewriter Ed for Apple ADB Bus CP513 PEN EMULATION 121 Delfi TECHNOLOGIES DELFISCAN C80 STRING Handshaking CE0 CE1 CE2 CE3 ACK NACK Protocol FIFO ECO EC1 CK00
19. 17 40 63 7 18 41 0 64 19 42 E 65 V 20 43 F 66 21 0 67 22 1 45 H 68 underscore 23 2 46 1 69 24 3 47 J 70 4 25 4 48 71 26 5 49 L 72 27 6 50 M 73 74 DEL 32 Delfi TECHNOLOGIES PEN EMULATION OPERATING MODE MINIMUM OUTPUT PULSE CONVERSION TO CODE 39 OVERFLOW OUTPUT LEVEL IDLE LEVEL INTER BLOCK DELAY 1 e Read the Enter Configuration code ONCE available at the top of each 2 e Read configuration codes from the desired groups Default value 3 Read the Exit and Save Configuration code ONCE available at the top of each page 33 Delfi TECHNOLOGIES PEN EMULATION The operating mode parameters are complete commands and do not require reading the Enter and Exit configuration codes OPERATING MODE interpret mode Interprets commands without sending them to the decoder transparent mode Sends commands to the decoder without interpreting them 34 Delfi lp TECHNOLOGIES MINIMUM OUTPUT PULSE high resolution code emulation 200 us 400 us 600 us 800 us 1ms 1 2 ms e emulation See par 4 2 1 for details 35 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VALLA PEN EMULATION VAN CONVERSION TO CODE 39 gt disable conversion to Code
20. Delta IBM Code 11 Code 16K Code 49 and RSS Codes 4 2 3 Overflow This parameter generates a white space before the first bar and after the last bar of the code The selections are as follows narrow space 10 times the minimum output pulse medium space 20 times the minimum output pulse wide space 30 times the minimum output pulse 107 1 1 TECHNOLOGIES DELFISCAN C80 4 2 4 Output and Idle Levels The following state diagrams describe the different output and idle level combinations for Pen emulation idle bar OUTPUT Normal black space IDLE Normal P white barcode output OUTPUT Normal par idle space IDLE Inverted barcode output gt OUTPUT Inverted SHOES idle bar IDLE Normal barcode output gt OUTPUT Inverted idle space IDLE Inverted barcode output Output and Idle Levels 4 2 5 Inter Block Delay For the PEN Emulation interface data are sent to the Host in fixed size blocks of 20 characters each The inter block delay parameter allows setting a delay between each block sent to the Host 108 Delfi TECHNOLOGIES REFERENCES DATA FORMAT 4 2 6 Header Terminator Selection The header terminator selection is not affected by the reading of the restore default code In fact header and terminator default values depend on the interface selection RS232 and USB COM no header terminator CR LF WEDGE and USB KBD
21. RTS CTS handshaking Software handshaking XON XOFF During transmission if the Host sends the XOFF character 13 Hex the decoder interrupts the transmission with a maximum delay of one character and only resumes when the XON character 11 Hex is received Transmitted data Transmitted data x L XON Host busy Host ready XON XOFF handshaking 105 1 1 TECHNOLOGIES DELFISCAN C80 4 1 2 ACK NACK Protocol This parameter sets a transmission protocol in which the Host responds to the reader after every code transmitted The Host sends an ACK character 06 HEX in the case of good reception or the NACK character 15 HEX requesting re transmission in the case of bad reception If the reader does not receive an ACK or NACK transmission is ended after the RX Timeout see par 4 1 4 Selection of the ACK NACK protocol automatically disables FIFO buffering see par 4 1 3 4 1 3 FIFO This parameter determines whether data barcodes are buffered on a First In First Out basis allowing faster data collection in certain cases for example when using slow baud rates and or hardware handshaking If the FIFO buffering is enabled codes are collected and sent out on the serial line in the order of acquisition Several hundred characters can be collected buffer full after which the reader signals an error and discards any further codes until the transmission is restored If
22. code says Delfi TECHNOLOGIES se 84 Colega 84 RSS GOGS 85 ADVANCED FORMATTING Concatenation Advanced Formatting 4 j A HOST CONFIGURATION STRINGS B CODE IDENTIFIER TABLE Delfi TECHNOLOGIES CONFIGURATION METHODS Reading Configuration Barcodes If you wish to change the default settings this manual provides complete configuration of your reader in an easy way To configure your reader 1 Open the folded page in Appendix with the hex numeric table and keep it open during the device configuration 2 Read the Enter Configuration code ONCE available at the top of each page of configuration 3 Modify the desired parameters in one or more sections following the procedures given for each group 4 Read the Exit and Save Configuration code ONCE available at the top of each page of configuration Reference notes describing the operation of the more complex parameters are given in chapter 4 Using DL SmartSet DL Sm rtSet is a Windows based utility program providing a quick and user friendly configuration method via the RS232 or USB COM interfaces It also allows upgrading the software of the connected device see the DL Sm rtSet User s Manual for more details Copy Command A previously configured reader Master
23. second character replacement EO2afg third character replacement ASCII character d a number from the Hex Numeric Table g values representing an ASCII character e f a ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 40 d a number in the range 01 32 from the Hex Numeric Table e Hex value from 00 to FE f Hex value of the character to be replaced from 00 to FE g Hex value of the new character to insert from 00 to FE FF replace with no new character remove character POWER SAVE DESCRIPTION STRING Scan Rate BTO BTI BT2 BQO Sleep State USB Suspend Enter Sleep Timeout 100 ms BR00 BR99 Delfi lp TECHNOLOGIES HOST CONFIGURATION STRINGS READING PARAMETERS Hand Held Operation fwaewgge mo hardware trigger sa mtmaic Awason ee hardwaretiggerready sa Stand Operation ofwaewgge em hardware trigger mtomaic Bua Hardware Trigger Signal trigger active level PT ER Reads per Cycle Beeper Intensity beeper off lowintensity O medium intensity BG Bo Beeper Tone pone tone2 2 toned BH3 Beeper Type MEN m Beeper Length Good Read Spot Duration disable short BV medium 2 long Stand Recognition Beep pembe Ba Automatic Operation Aiming Light
24. 2 4600 135 70 Stockholm 3370 Vikersund Tel 45 70 222 555 Tel 46 8 742 20 55 Tel 47 32 78 12 11 Fax 45 70 222 666 Fax 46 8 742 21 56 Fax 45 70 222 666 www delfi com info delfi com 2009 Delfi Technologies A S All rights reserved 07 09
25. 4 keys simultaneously on the keyboard to transmit the character S to the video to set the S press and release Shift then press and release 4 Each pressed and released key must generate an acoustic signal on the reader otherwise repress the key Never press more than one key at the same time even if this corresponds to the normal use of your keyboard Press Backspace to correct a wrong key entry In this case the reader emits 2 beeps Note CAPS LOCK and NUM LOCK must be off before starting the keyboard setting procedure SHIFT must be repressed for each character and cannot be substituted by CAPS LOCK 110 Delfi Enter Configuration Exit and Save Configuration Set Custom Extended Header Terminator Keys Read the code above e Ifthe first 4 KEYS Shift Alt Ctrl and Backspace are not available on your keyboard you can only substitute them with keys not used or substitute them with each other e 5 to 28 must be defined Press the desired keys in the following order The reader signals the end of the procedure with 2 beeps indicating the keys have been registered CUSTOM EXTENDED KEYBOARD SETTING TABLE a TECHNOLOGIES Delfi TECHNOLOGIES DELFISCAN C80 4 3 POWER SAVE 4 3 1 Sleep State USB Suspend When using standard devices this mode allows the P in the reader to enter a Sleep state for minimum power
26. Ack Nack protocol FIFO Inter character delay Rx timeout Serial trigger lock USB KBD Keyboard nationality FIFO Inter character delay Inter code delay Control character emulation USB IBM No parameter selection required 1 e Readthe Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and follow the procedure given Default value 3 Read the Exit and Save Configuration code ONCE available at the top of each page 12 Delfi TECHNOLOGIES Exit and Save Configuration Enter Configuration USB COM HANDSHAKING disable hardware RTS CTS software XON XOFF RTS always ON See par 4 1 1 for details ACK NACK PROTOCOL disable enable See par 4 1 2 for details FIFO disable enable 13 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VTA USB COM HE See par 4 1 3 for details INTER CHARACTER DELAY delay between characters transmitted to Host Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 milliseconds delay disabled 14 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration USB COM
27. Character Fixed Field 9 Field Transmission number of fields to transmit Read number the range 1 to 7 for the number of fields to transmit Include only fields to transmitted 100 Delfi Exit and Save Configuration ADVANCED FORMATTING II Field Order Transmission Read the codes corresponding to the fields to transmit in the order in which they are to be transmitted A field can be transmitted more than once See example field 1 field 2 field 3 field 4 field 5 additional field 1 additional field 2 Example The barcode is divided into 3 defined fields plus 1 additional fixed field Transmit in the order Field 2 Additional Field 1 Field 1 Field 2 Number of Fields to Transmit Field 2 Additional Field 1 Field 1 Field 2 II Im 10 Standard Formatting do not apply standard formatting apply standard formatting After performing Advanced Formatting on the barcode read Standard Formatting Headers Code Length Code ID Terminators can be applied to the message to be transmitted 11 End Format Definition end Format 1 definition 101 TECHNOLOGIES Delfi TECHNOLOGIES Exit and Save Configuration ADVANCED FORMATTING II end Format 2 definition end Format 3 definition
28. IN TRANSMISSION The start stop character case selections below are valid for the entire Codabar family transmit start stop characters in lower case transmit start stop characters in upper case 78 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration CODE SELECTION MSI disables the family Enable the code by selecting one of the check digit selections no check digit control MOD10 check digit control no check digit transmission MOD10 check digit control check digit transmission MOD11 MOD10 check digit control no check digit transmission MOD11 MOD10 check digit control check digit transmission MOD10 MOD10 check digit control no check digit transmission MOD10 MOD10 check digit control check digit transmission 79 TECHNOLOGIES Enter Configuration Exit and Save Configuration CODE SELECTION PLESSEY disables the family Enable the code by selecting one of the check digit selections Standard Plessey no check digit control check digit control check digit transmitted check digit control check digit not transmitted Anker Plessey no chec
29. SELECTION CODABAR FAMILY disables the family D Read the desired equality control code Read start stop transmission selection START STOP CHARACTER TRANSMISSION Standard Codabar start stop character equality control no transmission Standard Codabar start stop equality control transmission The Codabar ABC code below uses a fixed start stop character transmission selection Codabar ABC no start stop character equality control but transmission 77 TECHNOLOGIES Enter Configuration Exit and Save Configuration CODE SELECTION Codabar Forced Concatenation enable Codabar ABC with forced concatenation non start stop character equality control but transmission CODE LENGTH optional The code length selection is valid for the entire Codabar family Read the code 4 numbers for the code length where set code length First 2 digits minimum code length Second 2 digits maximum code length The maximum code length is 99 characters The minimum code length must always be less than or equal to the maximum Examples 0199 variable from 1 to 99 digits in the code 1010 10 digit code length only START STOP CHARACTER CASE
30. available at the top of each page 2 e Read configuration codes from the desired groups Default value 3 Read the Exit and Save Configuration code ONCE available at the top of each page 62 IU TECHNOLOGIES Enter Configuration Exit and Save Configuration SPREAD disable enable See par 4 5 1 for details OVERFLOW CONTROL disable enable See par 4 5 2 for details 63 IU TECHNOLOGIES Enter Configuration Exit and Save Configuration pecopinGPARAMETERS H INTERDIGIT CONTROL disable enable See par 4 5 3 for details DECODING SAFETY one read decoding safety disabled two reads three reads four reads Required number of good reads before accepting code 64 IU TECHNOLOGIES Enter Configuration Exit and Save Configuration DECODING parameters NI PUZZLE SOLVER disable enable In the case of damaged or poorly printed codes this parameter allows reading multiple parts of the single code to reconstruct it To read codes using this technology simply move the reader over the code so that each line of the code is scanned Conditions This parameter is only valid for the following codes EAN8 EAN 13 UP
31. code ONCE available at the top of each page 39 Delfi TECHNOLOGIES DATA FORMAT CODE IDENTIFIER TABLE CODE AIMSTANDARD DATALOGICSTANDARD Custom 2 5 interleaved N 2 5 industrial 2 5normal5 bars 0 Jsmatix3bas py 0 PANG a S a EAN 10 PG EANBWIh2ADDON 18 1 JEANSwithSADDON 16 JEAN 13 with2 ADDON ge Pb EAN 13 with5 ADDON 12 JUPCAwith2ADDON JUPCAwithSADDON JUPCEwith2ADDON 8 JUPCEwithSADDON 1 code39 Ay v Code 39FullAscH 1 4 CODABAR 8 ABCCODABAR 1 65 code128 JCy 7 EN128 1 87118 1 code93 24 21 32 1 272 Plessey Standard 1 Po Plessey Anker Teepen Detam coden 1 code16k_ K0 Co j j a 2 RSSExpandedlinearandStaced 10 RSS 14LinearandStacked 120 40 Delfi TECHNOLOGIES DATA FORMAT AIM standard identifiers are not defined for all codes the X identifier is assigned to the code for which the standard is not defined The y value depends on the selected options check digit tested or not check digit tx or not etc e When customizing the Datalogic Standa
32. consumption This command is only valid when hardware trigger type is selected Before entering Sleep mode the following are verified e coming from Host e data being transmitted to Host e Enter Sleep Timeout ended see par 4 3 2 It is possible to exit Sleep mode either by pressing the button trigger or by inserting the reader into the Stand only for devices with Stand Recognition Beep Enabling the Sleep State USB Suspend implements Standby mode for CCD devices see par 4 3 3 When using USB devices this mode allows the device to manage Selective Suspend conditions generated by the Host Operating System in which optimizing low power consumption ex Windows Stand by It is possible to exit the Suspend mode either from the Host ex moving the mouse during Stand by or through the barcode reader The latter called Remote Wakeup makes the device wake up the Host restoring the communication Remote Wakeup is possible either by pressing the button trigger or by putting the reader into the stand only for devices with Stand Recognition Beep 4 3 2 Enter Sleep Timeout For readers that have the Sleep state enabled this timeout determines when the reader will enter this state 4 3 3 Standby only for CCD devices If this command is enabled part of the CCD circuitry shuts down Standby in order to optimize low power consumption when not reading When the trigger is pressed this circuitry powers up Thi
33. control NT _ but transmission Codabar ABC forced concatenation AD232 code length start stop character case in lower case ADAO transmission uppercase Code 128 disable Code 128 famiy T m enable Code 128 control without transmission of checkdigt an enable EAN 128 control without transmission of check digt addGSbeforeCode aiae mae hrs emalesPrin ai disable Code 93 family AKO enable Code 93 control without transmission of check digit AX disablethefamiy ya nochek MOD10 with MODI MODIOnow MODIOMODIOnow fa ar xxxx ASCII numbers that define the code length where e First 2 digits minimum acceptable code length e Second 2 digits maximum acceptable code length The minimum code length must always be less than or equal to the maximum The maximum code lengths are 99 characters Examples 0132 variable length from 1 to 32 digits in the code 1010 10 digit code length only Delfi lp TECHNOLOGIES HOST CONFIGURATION STRINGS CODE SELECTION continued DESCRIPTION STRING Plessey disable the family Standard no check Standard check with tx Standard check no tx Anker no check Anker check with tx Anker check no tx Telepen disable the family Numeric no check Numeric check with t
34. l Delta IBM Telepen 16 11 Code 49 RSS Expanded Linear and Stacked 133 DELFISCAN C80 Delfi TECHNOLOGIES RSS Limited RSS 14 Linear and Stacked Delfi TECHNOLOGIES C HEX AND NUMERIC TABLE CHARACTER TO HEX CONVERSION TABLE 80 a AA D5 81 lt AB D6 5 82 D7 ENTER 83 AD 0 D8 TAB 84 AE D9 F1 85 AF DA F2 86 BO DB F3 87 t B1 DC F4 88 2 B2 Y DD F5 89 2 B3 b DE F6 8A B4 B DF F7 8B B5 EO F8 8C q B6 E1 F9 8D B7 E2 F10 B8 F11 8F B9 E4 F12 90 BA E5 HOME 91 gt BB E6 END 92 1 4 BC E7 Pg UP 93 BD E8 Pg Down 94 E9 95 BF EA v 96 A C0 EB lt 97 C1 i EC gt 98 2 ED ESC 99 C3 i EE CTRL Right 9 C4 i EF 9B C5 6 FO 9 C6 f F1 9D 5 2 2 9 C8 6 F3 Y 9F C9 F4 NBSP A0 CA 6 F5 A1 CB F6 A2 i cc F7 A3 CD 0 F8 n 4 1 F9 X A5 i CF FA A6 DO FB 8 A7 N D1 FC A8 D2 y FD A9 D3 Reserved FE D4 Reserved FF 135 Delfi HEX AND NUMERIC TABLE HL Hi Delfi TECHNOLOGIES Denmark Sweden Norway Galoche Alle 1 Solkraftsv gen 25 Rugdetrekket
35. no fixed field 1 character fixed field 2 fixed field P AVA 3 character fixed field P 4 character fixed field 5 character fixed field 6 character fixed field P After selecting one of the Additional Fixed Field codes read the corresponding character s from the HEX table Range of characters 01 FE For readers using Wedge interface all values from 9C to FE send the Space character Example 4 Character Fixed Field 8 Second Additional Fixed Field 4D 41 49 MAIN no fixed field 99 Delfi TECHNOLOGIES Exit and Save Configuration ADVANCED FORMATTING II 1 character fixed field P OLE ITI 2 character fixed field P 3 character fixed field 4 character fixed field JULI T 5 character fixed field 6 character fixed field After selecting one of the Additional Fixed Field codes read the corresponding character s from the HEX table Range of characters 01 FE For readers using Wedge interface all values from 9C to FE send the Space character Example 3
36. 39 Transmits codes in their original format enable conversion to Code 39 Converts codes read into Code 39 format See par 4 2 2 for details OVERFLOW narrow medium wide See par 4 2 3 for details 36 Delfi TECHNOLOGIES OUTPUT LEVEL normal white logic level 0 inverted white logic level 1 See par 4 2 4 for details IDLE LEVEL normal black level inverted white level See par 4 2 4 for details 37 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VALLA PEN EMULATION VAN INTER BLOCK DELAY delay between character blocks transmitted to Host Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 9 9 seconds delay disabled See par 4 2 5 for details 38 Delfi TECHNOLOGIES DATA FORMAT NOT FOR PEN INTERFACES CODE IDENTIFIER CUSTOM CODE IDENTIFIER HEADER TERMINATOR FIELD ADJUSTMENT FIELD ADJ CHARACTER CODE LENGTH TX CHARACTER REPLACEMENT 00000000 1 e Read the Enter Configuration code ONCE available at the top of each page 2 e Read configuration codes from the desired groups Read the code and follow the procedure given Default value 3 Read the Exit and Save Configuration
37. 7 CONFIGURATION COPY COMMAND Procedure Connect the master correctly configured reader and the slave reader to be configured together through two RS232 serial interface cables and external power supply Accessory cables and power supply are available from your Delfi distributor to provide this connection RS232 Cables CAB363 amp CAB364 or CAB320 amp CAB328 Power Supply PG5 Using the slave device read the Restore Default barcode and then the RS232 interface barcode from par 2 1 2 of this manual or from the Quick Reference Manual With the master device read the Configuration Copy barcode below Copy Configuration The configuration will be copied from the master to the slave device The slave device signals the end of the procedure with a series of beeps Note The master device can be configured for any interface 117 Delfi TECHNOLOGIES DELFISCAN C80 4 8 DEFAULT PARAMETERS FOR POS SYSTEMS The default values for the RS232 and Data Format parameters for POS systems are listed in the following table MEE NIXDORF Mode A FUJITSU ICL Mode Party Odd Noe Even Data Bits 8 8 8 Stop Bis 7 12 70 c 3 j 1 Field Adjustment Not Transmitted The table below lists all the Code Identifiers available for POS systems FF C code length Code 39 C code length N code length JUCC EAN 128 O O MSI Plessey Code 11 118 Delfi
38. 9 bits STOP BITS 1 stop bit 2 stop bits 21 Enter Configuration 85232 HANDSHAKING disable hardware RTS CTS software XON XOFF RTS always ON See par 4 1 1 for details ACK NACK PROTOCOL disable enable See par 4 1 2 for details 22 Delfi TECHNOLOGIES Exit and Save Configuration Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration 85232 FIFO disable enable See par 4 1 3 for details 23 Delfi TECHNOLOGIES Enter Configuration 24 Exit and Save Configuration RS232 VGA INTER CHARACTER DELAY delay between characters transmitted to Host Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 milliseconds delay disabled Rx TIMEOUT timeout control in reception from Host Read 2 numbers from the table where 00 TIMEOUT disabled 01 99 TIMEOUT from 1 to 9 9 seconds rx timeout 5 seconds See par 4 1 4 for details Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration 85232 TN SERIAL TRIGGER LOCK disabled enable and select characters 1 Read 2 characters from the Hex Numeric tab
39. CA without Add on without Add on without Add on Code 128 Code 39 For Code 39 Check digit control without transmission is forced PuzzleSolver is disabled when code ISBT 128 is enabled 65 Delfi TECHNOLOGIES CODE SELECTION EAN UPC FAMILY 2 5 FAMILY CODE 39 FAMILY CODE 128 FAMILY CODABAR FAMILY CODE 93 MSI PLESSEY TELEPEN DELTA IBM CopE 11 CopE 16K CODE 49 RSS CODES 1 e Read the Enter Configuration code ONCE available at the top of each page 2 e Read configuration codes from the desired groups Read the code and follow the procedure given Default value 3 Read the Exit and Save Configuration code ONCE available at the top of each page 66 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration CODE SELECTION DISABLES ALL CODE FAMILIES The reader allows up to 5 code selections This does not limit the number of CODES enabled to 5 as it depends on the code family SINGLE SELECTIONS ONE combination code from the EAN family ONE code from the 2 5 family Example 5 code selections 1 2 5 Interleaved 2 5 Industrial Code 128 EAN 128 Code 39 Full ASCII Code 32 UPC A UPC E EE MEE In this section all SINGLE code selections are underlined and in bold 67 TECHNOLOG
40. Delfi DelfiScan C80 Programming Manual Delfi TECHNOLOGIES Delfi Technologies A S Galoche Alle 1 DK 4600 Kage Denmark Telephone 45 70 222 555 Fax 45 70 222 666 An Unpublished Work All rights reserved No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written per mission of Delfi Technologies A S Owners of Delfi products are hereby granted a non exclusive revocable license to reproduce and transmit this documentation for the purchaser s own internal business purposes Purchaser shall not remove or alter any proprietary notices including copyright notices contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation Electronic versions may either be downloadable from the Delfi website www delfi com or provided on appropriate media Disclaimer Delfi has taken reasonable measures to provide information in this manual that is complete and accurate however Delfi reserves the right to change any specification at any time without prior notice Delfi TECHNOLOGIES CONTENTS 1 INTRODUCTION esneenesvesvvenensvnsnesnesnnnsnesnennesnnnnensnnnnennnsennenesnesnessnsnnneneneesenee 1 2 0 3 3 2 1 21
41. FO 2 so STRING Minimum output pulse Output evel iie leve PN Overflow Delfi TECHNOLOGIES HOST CONFIGURATION STRINGS DATA FORMAT NOT FOR PEN EMULATION INTERFACES DESCRIPTION STRING Code Identifier disable EBO Datalogicstandard fem Custom EB3 CwstomCodeldender made Headers nohede onechader O ao three characters EA03xxx four characters five characters seven characters Terminators noterminator Emo twocharacters Emax three characters five characters Emso six characters EAl66o a ASCII character b cx values representing an ASCII character a ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 40 b Hex value of the first Custom Code Identifier character from 00 to FE FF disable Code Identifier c Hex value of the second Custom Code Identifier character from 00 to FE FF disable second character of Custom Code Identifier x Hex value from 00 to FE Code Length Tx ummied Field Adjustment ded eo fO Metadon right deletion Ed 125 Delfi TECHNOLOGIES DELFISCAN C80 mamn Ted FieldAdjustmentCharacter Character Replacement disable characterreplacement Eoo
42. IES Enter Configuration Exit and Save Configuration CODE SELECTION EAN UPC FAMILY disable the family Read the desired family code Note Since the EAN UPC without ADD ON code selection is enabled by default to correctly enable another selection first disable the family EAN 8 EAN 13 UPC A UPC E with and without ADD ON WITHOUT ADD ON EAN 8 EAN 13 UPC A UPCE EAN 8 EAN 13 UPC A UPCE 68 TECHNOLOGIES Enter Configuration Exit and Save Configuration JE CODE SELECTION WITH ADD ON 2 AND 5 EAN 8 EAN 13 UPC A UPCE EAN 8 EAN 13 UPC A UPCE WITH ADD ON 2 ONLY EAN 8 EAN 13 UPC A UPCE WITH ADD ON 5 ONLY EAN 8 EAN 13 UPC A UPCE 69 TECHNOLOGIES Enter Configuration Exit and Save Configuration CODE SELECTION EAN UPC CHECK DIGIT TX SELECTIONS For each code type in this family you can choose to transmit the check digit or not CHECK DIGIT TRANSMISSION NO CHECK DIGIT TRANSMISSION EAN8 EAN 8 EAN 13 EAN 13 UPCA UPCA UPCE UPCE 70 Enter Configuration CODE SELECTION CONVERSION OPTIONS UPC Eto UPC A conversion UPC E to EAN 13 conversion UPC A to EAN 13 conversion EAN 8to EAN 13 conversion Enable only ISBN conversion Enable
43. aracter terminator MUNNEN seven character terminator x MA eight character terminator After selecting one of the desired Header codes read the character s from the HEX table Valid characters are in the range 00 FE Example two character terminator 0D Terminator CR LF For more details see par 4 2 6 SPECIAL KEYS Available only for Wedge IBM AT PS 2 and USB KBD Interfaces 45 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VA DATA FORMAT VAN It is necessary to define each Special Key by following the procedure given in par Fejl Henvisningskilde ikke fundet Select one or more of the following Special Keys according to your needs Special Key 1 Special Key 2 Special Key 3 Special Key 4 Special Key 5 46 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration DATA FORMAT FIELD ADJUSTMENT disable field adjustment Field adjustment allows a number of characters n to be added to or subtracted from the barcode read The adjustment can be different for each enabled code type To define the field adjustment O Read the enable field adjustment code enable field adjustment axe ill Select the cod
44. ation code ONCE available at the top of each page 51 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration POWER SAVE SCAN RATE CCD Readers ONLY quarter half maximum A lower scan rate reduces power consumption but can lengthen reading response time SLEEP STATE USB SUSPEND ONLY Devices with Button Trigger disable enable See par 4 3 1 for details ENTER SLEEP TIMEOUT ONLY Devices with Button Trigger enter sleep timeout d Read 2 numbers in the range 00 99 00 Enter Sleep state immediately 01 99 corresponds to a max 9 9 sec delay before entering the Sleep state See par 4 3 2 for details 52 Enter Configuration VA POWER SAVE STANDBY ONLY for CCD Devices disable optimize for reading speed enable optimize for low power consumption See par 4 3 3 for details Delfi TECHNOLOGIES Exit and Save Configuration 53 Delfi TECHNOLOGIES READING PARAMETERS HAND HELD OPERATION STAND OPERATION TRIGGER SIGNAL TRIGGER OFF TIMEOUT FLASH MODE READS PER CYCLE SAFETY TIME BEEPERINTENSITY BEEPER TONE BEEPER TYPE BEEPER LENGTH GOOD READ SPOT DURATION STAND RECOGNITION BEEP AUTOMATIC OPERATION AIMING LIGHT O
45. ault settings refer to par 4 8 2 1 3 Wedge Interface Selection Read the restore default code then read the interface selection code for your application RESTORE DEFAULT WEDGE INTERFACE IBM AT or PS 2 PCs IBM XT Delfi TECHNOLOGIES DELFISCAN C80 PC Notebook IBM SURE1 IBM Terminal 3153 WEDGE INTERFACE CONTINUED IBM Terminals 31xx 32xx 34xx 37xx To select the interface for these IBM Terminals read the correct KEY TRANSMISSION code Select the KEYBOARD TYPE if necessary default advanced keyboard KEY TRANSMISSION MODE make only keyboard make break keyboard KEYBOARD TYPE advanced keyboard typewriter keyboard ALT MODE The following interface selection allows barcodes sent to the PC to be interpreted correctly independently from the Keyboard Nationality used You do not need to make a Keyboard Nationality selection default Num Lock Unchanged Make sure the Num Lock key on your keyboard is ON IBM AT ALT mode Delfi TECHNOLOGIES INITIAL SETUP PC Notebook ALT mode WEDGE INTERFACE CONTINUED WYSE TERMINALS ANSI Keyboard PC Keyboard ASCII Keyboard VT220 style Keyboard DIGITAL TERMINALS VT2xx VT3xx VT4xx APPLE APPLE ADB Bus 2 1 4 Pen Emulation Interface Selection Read the restore default code then read th
46. correctly HHHH loading error reading or writing error in the non volatile long tones memory HLHL Hardware error in EEPROM OFF No beeper performed when illuminator line is kept high at power on READER CONFIGURATION READER DATA ENTRY OFF OFF ready to read a code only the Beeper Intensity command can modify these signals 1 the data entry good read tone is user configurable with all the Beeper commands in the Reading Parameters section Delfi TECHNOLOGIES INITIAL SETUP 2 INITIAL SETUP 2 1 INTERFACE SELECTION Follow the procedure to configure the interface required by your application e USB Interface e RS232Interface e Wedge Interface Emulation Interface 2 1 1 USB Interface Configuration The USB interface is compatible with Windows 98 and later Mac OS 8 0 and later IBM POS for Windows 4690 Operating System The USB interface is compatible with Windows 98 and later IBM POS for Windows Mac OS 8 0 and later 4690 Operating System START UP As with all USB devices upon connection the Host performs several checks by communicating with the USB device During this phase the LED on the device blinks and normal operations are suspended Two basic conditions must be met before the USB device is ready to read codes the correct USB driver must be loaded and sufficient power must be supplied to the reader
47. device can be used to send its configuration directly to other readers of the same type The particular procedure for each device is given in par 4 7 Sending Configuration Strings from Host An alternative configuration method is provided in Appendix A using the RS232 or USB interfaces This method is particularly useful when many devices need to be configured with the same settings Batch files containing the desired parameter settings can be prepared to configure devices quickly and easily vi Delfi TECHNOLOGIES INTRODUCTION 1 INTRODUCTION This manual provides all the necessary information for complete software configuration of DelfiScan C80 Your reader contains a built in decoder and multi standard interface It is designed for use in a wide variety of applications and environments including commercial office automation retail and light industrial applications where large quantities of information need to be collected rapidly easily and reliably It has several status indicator functions which are described in the next paragraph Delfi TECHNOLOGIES DELFISCAN C80 1 1 STATUSINDICATORS Several status indicators are available depending on the type of reader LEDs Beeper and Good Read Spot for CCD Long Range readers only They signal several operating conditions which are described in the tables below high tone L low tone READER START UP we LLLL Parameters loaded
48. dix code length Read a number in the range 01 99 from the Hex Numeric Table 3 Concatenation Result Code ID use code 2 ID Since you can concatenate codes from different families you must select the Code ID character of the resulting code The Code ID character will be sent in the output message only if it is enabled according to the Code Identifier selection Datalogic AIM or Custom use code 1 ID 4 Concatenation Timeout timeout 1 JULII Read two numbers in the range 00 to 99 00 no timeout 01 99 timeout from 1 to 99 seconds Define the timeout which determines the valid waiting period between the two codes in order to accept concatenation If the timeout expires the resulting action will be based on the following selection 5 Transmission after Timeout no code transmitted after timeout only code 1 transmitted if read after timeout 88 Delfi TECHNOLOGIES Exit and Save Configuration ADVANCED FORMATTING II only code 2 transmitted if read after timeout either code 1 or code 2 transmitted after timeout 89 Delfi TECHNOLOGIES ADVANCED FORMATTING ADVANCED FORMATTING Advanced formatting has been designed to offer you complete flexibility in changing the format of barcode data before transmitting it to the host system This formatting will be performed when the barcode da
49. e 00 99 00 disables the trigger off timeout 01 99 corresponds to max 99 sec delay after the trigger press to allow the reader to turn off automatically trigger off timeout disabled See par 4 4 3 for details 56 Enter Configuration II III READING PARAMETERS FLAsH MopE FLASH ON duration FLASH OFF duration Read 2 numbers in the range 01 99 01 to 99 from 1 to 9 9 seconds Flash ON 1 sec Flash OFF 0 6 sec READS PER CYCLE one read per cycle multiple reads per cycle See par 4 4 4 for details Delfi TECHNOLOGIES Exit and Save Configuration 57 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration JE READING PARAMETERS SAFETY TIME safety time Limits same code consecutive reading Read 2 numbers in the range 00 99 00 no same code consecutive reading until reader is removed no decoding for at least 400 ms 01 99 timeout from 1 to 9 9 seconds before a consecutive read on same code safety time 0 5 sec See par 4 4 5 for details BEEPER INTENSITY beeper off low intensity medium intensity high intensity This sets the beeper OFF for data entry while for all other beeper signals it has the meaning very low intensity The Beeper Intensi
50. e Pen Emulation interface selection code RESTORE DEFAULT Delfi DELFISCAN C80 PEN EMULATION Delfi TECHNOLOGIES CONFIGURATION 3 CONFIGURATION gt Once your reader is setup you can change the default parameters to meet your application needs Refer to chapter 2 for initial configuration in order to set the default values and select the interface for your application In this manual the configuration parameters are divided into logical groups making it easy to find the desired function based on its reference group The first four groups are for Standard Interface parameter configuration USB e RS232 e WEDGE PEN EMULATION The following parameter groups are common to all interface applications DATA FORMAT parameters regard the messages sent to the Host system for all interfaces except Pen Emulation POWER SAVE manages overall current consumption in the reading device READING PARAMETERS control various operating modes and indicator status functioning DECODING PARAMETERS maintain correct barcode decoding in certain special reading conditions CODE SELECTION parameters allow configuration of a personalized mix of codes code families and their options ADVANCED FORMATTING PARAMETERS allow code concatenation and advanced formatting of messages towards the Host It cannot be used with Pen Emulation 11 Delfi TECHNOLOGIES USB PARAMETERS USB COM Handshaking
51. e type from the Code Identifier Table in Appendix Select the type of adjustment to perform right addition left addition right deletion left deletion Read a number in the range 01 32 from the Hex Numeric Table to define how many characters to add or delete Conditions e Adjustment is only performed on the barcode data the Code Identifier and Code Length Transmission fields are not modified by the field adjustment parameter e Ifthe field setting would subtract more characters than exist in the barcode the subtraction will take place only to code length 0 e You can set up to a maximum of 10 different field adjustments on the same barcode family or on different barcode families Example To add 4 characters to the right of Standard Code 39 Codes enable field adjustment Code 39 right addition FIELD ADJUSTMENT CHARACTER 04 D Read the field adjustment character code field adjustment character eC Read the hexadecimal value corresponding to the character you want to use for field adjustment Valid characters are in the range 00 FE 47 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VA DATA FORMAT Example To define the field adjustment character A field adjustment character read lt
52. fter the desired period of time 4 4 4 Reads per Cycle In general a reading cycle corresponds to the ON OFF times of a device The resulting effects of this parameter on code reading depend on other related configuration conditions Here are the definitions of ON and OFF times e For readers using the software trigger parameter FLASH MODE a reading cycle corresponds to the flash on flash off times Code reading takes place during the flash on time e For readers using the hardware trigger parameter a reading cycle corresponds to trigger press ON one of the following OFF events trigger release for trigger active level a second trigger press for trigger active pulse trigger off timeout see par 4 4 3 113 Delfi TECHNOLOGIES DELFISCAN C80 When one read per cycle is selected the device decodes only one code during the ON period and immediately turns the reader OFF It is only possible to read another code when the next ON time occurs In multiple reads per cycle the ON period is extended so that the device can continue decoding codes until an OFF event occurs For software trigger mode the flash on period is immediately reset after each read and therefore extended If another code is decoded before the reset flash on period expires it is again reset and the effect is that the device remains ON decoding codes until the flash on or timeout period expires The Safety Time parameter should be used i
53. ifier s Code 39 e NI 43 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VA DATA FORMAT VAN HEADER no header one character header z MNT two character header UMN three character header four character header z MAN five character header six character header seven character header z eight character header HUNNEN After selecting one of the desired Header codes read the character s from the HEX table Valid characters are in the range 00 FE Example four character hea For more details see par 4 2 6 der 41 42 43 44 Header ABCD 44 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration DATA FORMAT TERMINATOR no terminator HMM AT one character terminator 2587 two character terminator za MAN three character terminator a four character terminator MUNN five character terminator za six ch
54. is case the reader emits 2 beeps Note CAPS LOCK and NUM LOCK must be off before starting the keyboard setting procedure SHIFT must be repressed for each character and cannot be substituted by CAPS LOCK setting the alohanumeric keyboard d Read the code above Press the keys shown in the following table according to their numerical order 31 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VA WEDGE Some characters may be missing as this depends the type keyboard these are generally particular characters relative to the various national symbologies In this case e first 4 characters Shift Alt Ctrl and Backspace can only be substituted with keys not used or substituted with each other e characters can be substituted with other single symbols e g SPACE even if not included in the barcode set used e characters be substituted with others corresponding to your keyboard The reader signals the end of the procedure with 2 beeps indicating the keys have been registered 01 Shift 02 Alt 03 Ctrl 04 Backspace 05 SPACE 28 7 51 N 06 29 8 52 0 07 30 9 53 P 08 31 54 Q 09 32 55 R 10 96 33 56 5 11 34 57 12 35 gt 58 U 13 36 59 V 14 37 09 60 W 15 38 A 61 X 16 4 39 B 62 Y
55. k digit control check digit control check digit transmitted check digit control check digit not transmitted 80 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration CODE SELECTION TELEPEN disables the family Enable the code by selecting one of the check digit selections Numeric Telepen no check digit control check digit control check digit transmitted check digit control check digit not transmitted Alphanumeric Telepen no check digit control check digit control check digit transmitted check digit control check digit not transmitted 81 TECHNOLOGIES Enter Configuration Exit and Save Configuration CODE SELECTION DELTA IBM disables the family Enable the code by selecting one of the check digit selections no check digit control Type 1 check digit control Type 2 check digit control 82 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration CODE SELECTION CopE 11 disables the family Enable the code by selecting one of the check digit selections
56. le NO and power up LEDoff BEEPOK Reconnect reader Select desired USB BEEPOK cable to Host and interface code close dialog box Load drivers ifre queste d Read test codes Readeris READY Delfi TECHNOLOGIES Delfi TECHNOLOGIES INITIAL SETUP Successive start ups will automatically recognize the previously loaded drivers If external power is used verify that external power is already supplied Successive Start Ups Connect device to Host with USB cable LED links Does a dialog boxappear asking whether Bus power is ufficientz Conn ect external power supply to cable NO andpower up LED off BEEP OK Reconnect reader BEEP OK cable to Host and close dialog box Readtest codes Reader isREADY Delfi TECHNOLOGIES DELFISCAN C80 USB INTERFACE USB KBD USB KBD ALT MODE USB KBD APPLE USB COM USB IBM Table Top USB IBM Hand Held When configuring USB COM the relevant files and drivers must be installed from the USB Device Installation software which can be downloaded from the web site see http www delfi com 2 1 2 RS232 Interface Selection Read the restore default code then read the interface selection code for your application RESTORE DEFAULT Delfi TECHNOLOGIES INITIAL SETUP RS232 INTERFACE Standard POS SYSTEMS Nixdorf Mode A Fujitsu ICL Mode For POS system def
57. le in the range 00 FE where First Character enables device trigger Second Character inhibits device trigger until the first character is received again 25 Delfi TECHNOLOGIES WEDGE PARAMETERS KEYBOARD NATIONALITY CAPS LOCK CAPS LOCK AUTO RECOGNITION Num Lock INTER CHARACTER DELAY INTER CODE DELAY CONTROL CHARACTER EMULATION KEYBOARD SETTING 1 Readthe Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups a Read the code and follow the procedure given Default value 3 Read the Exit and Save Configuration code ONCE available at the top of each page 26 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VA WEDGE VAN KEYBOARD NATIONALITY This parameter default value is restored through the Interface Selection code and not Restore Default Belgian English French German Italian Spanish Swedish USA The Japanese Keyboard Nationality selection is valid only for IBM AT compatible PCs Japanese 27 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VALLA WEDGE VAN CAPS LOCK caps lock OFF caps lock ON Select the appropriate code to match your keyboard caps lock statu
58. n this case to avoid unwanted multiple reading of the same code see par 4 4 5 4 4 5 Safety Time Safety time prevents the device from immediately decoding the same code more than once Same code consecutive reading can be disabled requiring the reader to be removed from the code no decoding for at least 400 ms or a timeout can be set up to 9 9 seconds before the decoder will accept the same code Reading is immediate if the code changes For Automatic Hand Held or Stand Operation the Safety Time parameter is forced to no code consecutive reading 00 The safety time parameter is not applicable when reading stacked codes or when setting one read per cycle in hardware trigger operating mode since these settings require voluntary action by the user 4 4 6 Automatic Operation Aiming Light This parameter is valid for CCD long range devices in Automatic Hand Held or Stand Operation and allows an aiming light to be continuously emitted in front of the reader to facilitate the positioning of the barcode to be read 4 4 7 Aiming System This parameter is valid for laser readers and provides a programmable H timeout for the aiming system If enabled the scan line emitted from the reading window is preceded by a red spot which must illuminate the code center to get the best reading performance see figure Once the defined timeout is reached the red spot disappears and is followed by the scan line to start the code scanning 2
59. no header terminator ENTER WEDGE ALT MODE and USB KBD ALT MODE no header terminator CR These default values are always restored through the reading of the relative interface selection code see chapter 2 For the WEDGE interface the following extended keyboard values can also be configured EXTENDED KEYBOARD TO HEX CONVERSION TABLE AT IBM 31xx 32xx Wyse IBM3153 34xx 37xx Digital APPLE ADB 33 ENTER ENTER FIELD EXIT RETURN 84 C Ri CTRL CTRL igh Space For all readers using Wedge interface all values from 9C to FE send the Space character 109 1 1 TECHNOLOGIES DELFISCAN C80 4 2 7 Set Custom Extended Header Terminator Keys The extended Header Terminator keys for Wedge Interface users can be customized by defining them through a simple keyboard setting procedure For example the Numeric Keypad keys can be set for use as Headers or Terminators by substituting the default extended keys using this procedure The type of computer or terminal must be selected before activating the keyboard setting command Press and release a key to set it Some characters may require more than one key pressed simultaneously during normal use refer to the manual of your PC or terminal for keyboard use The exact sequence must be indicated to the reader in this case pressing and releasing the different keys Example If one has to press the Shift and
60. ode 128 control without transmission of check digit EAN 128 control without transmission of check digit Transmit GS Before Code Code EAN 128 uses the ASCII GS character to separate a variable length code field from the next code field This character can also be transmitted before the code disable enable If the GS character has been modified in the Character Replacement parameter the new character is affected by this command ISBT 128 Enabling ISBT 128 automatically disables Puzzle Solver CODE LENGTH optional The code length selection is valid for the entire Code 128 family 75 TECHNOLOGIES Enter Configuration Exit and Save Configuration lll CODE SELECTION set code length Read the code 4 numbers for the code length where First 2 digits minimum code length Second 2 digits maximum code length The maximum code length is 99 characters The minimum code length must always be less than or equal to the maximum Examples 0199 variable from 1 to 99 digits in the code 1010 10 digit code length only The length is calculated on the output string CopE 93 disables the code Code 93 control without transmission of check digit 76 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration CODE
61. only ISSN conversion Enable both ISBN and ISSN conversion Disable both ISBN and ISSN conversion Delfi TECHNOLOGIES Exit and Save Configuration 71 TECHNOLOGIES Enter Configuration CODE SELECTION Exit and Save Configuration 2 5 FAMILY disables the family D Read the desired family code Interleaved 2 5 Normal 2 5 5 Bars Industrial 2 5 IATA Matrix 2 5 3 Bars The pharmaceutical code below is part of the 2 5 family but has no check digit or code length selections Code CIP HR French pharmaceutical code 72 Q Read a check digit selection CHECK DIGIT TABLE no check digit control check digit control and transmission check digit control without transmission Read 4 numbers for the code length where First 2 digits minimum code length Second 2 digits maximum code length The maximum code is 99 characters length The minimum code length must always be less than or equal to the maximum Examples 0199 the code 1010 10 digit code length only variable from 1 to 99 digits in Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration CODE SELECTION
62. oose to discard the code separator character or include it as the last character of the field ORBY b defining a match character to be found consecutively repeated in the code itself In this case the field ends with the first character that does not match ORBY C specifying a specific character length up to the maximum of 99 characters ORBY d selecting the last field as variable length if any You must define the same number of fields as selected in step 5 including fields that will not be transmitted 93 Delfi TECHNOLOGIES Exit and Save Configuration ADVANCED FORMATTING II DEFINE FIELD 1 BY EITHER field separator P Read the field separator character from the HEX table Range of characters 01 FE discard separator include separator OR match character 187 Read the match character from the HEX table Range of characters 01 FE OR field length P Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length i III AND Field 1 Terminators no field terminators 1 field terminator 2 field terminators Read the field terminator character s from the HEX table Valid range of characters for all readers 01 FE
63. rd code identifiers 1 or 2 identifier characters can be defined for each code type If only 1 identifier character is required the second character must be selected as FF disabled e The code identifier can be singly disabled for any code by simply selecting FF as the first identifier character e Write in the Custom character identifiers in the table above for your records 41 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration DATA FORMAT DALI CODE IDENTIFIER disable Datalogic standard AIM standard custom 42 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration DATA FORMAT CUSTOM CODE IDENTIFIER define custom code identifier s Read the above code Code Identifiers default to Datalogic standard see table on previous page Select the code type from the code table in Appendix for the identifier you want to change You can define 1 or 2 identifier characters for each code type If only 1 identifier character is required the second character must be selected as FF disabled Read the hexadecimal value corresponding to the character s you want to define as identifiers for the code selected in step valid characters are in the range 00 FD Example To define Code 39 Code Identifier define custom code ident
64. rminators 97 Delfi TECHNOLOGIES Exit and Save Configuration ADVANCED FORMATTING II Read the field terminator character s from the table Valid range of characters for all readers 01 FE For readers using Wedge interface all values from 9C to FE send the Space character DEFINE FIELD 5 BY EITHER field separator P Read the field separator character from the HEX table Range of characters 01 FE discard separator include separator OR match character NP Read the match character from the HEX table Range of characters 01 FE OR field length 13 Read two numbers the range 01 to 99 to define the field length OR this is the last field variable length AND Field 5 Terminators no field terminators 1 field terminator 2 field terminators Read the field terminator character s from the HEX table 98 Delfi TECHNOLOGIES Exit and Save Configuration ADVANCED FORMATTING II For readers using Wedge interface all values from 9 to FE send the Space character Valid range of characters for all readers 01 FE 7 First Additional Fixed Field
65. s Note Caps lock manual configuration is ignored when Caps Lock Auto Recognition is enabled For PC Notebook interface selections the caps lock status is automatically recognized therefore this command is not necessary CAPS LocK AUTO RECOGNITION IBM AT COMPATIBLE ONLY disable enable 28 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VALLA WEDGE VAN Num Lock toggle num lock num lock unchanged This selection is used together with the Alt Mode interface selection for AT or Notebook PCs It changes the way the Alt Mode procedure is executed therefore it should be set as follows e if your keyboard Num Lock is normally on use num lock unchanged e if your keyboard Num Lock is normally off use toggle num lock In this way the device will execute the Alt Mode procedure correctly for your application INTER CHARACTER DELAY delay between characters transmitted to Host Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 milliseconds delay disabled INTER CODE DELAY delay between codes transmitted to Host zd Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 seconds 29 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VA WEDGE VAN
66. s mode causes a minor delay before the reader is ready 112 Delfi TECHNOLOGIES REFERENCES 4 4 READING PARAMETERS 4 4 1 Hand Held and Stand Operation These parameter groups allow setting different reading modes for Hand Held Operation and Stand Operation e SoftwareTrigger the reader is set in FLASH MODE Code reading takes place during the flash on time e Hardware Trigger the code reading is started with a trigger press ON e Hardware Trigger Ready the illuminator is switched ON when the reader sees a code It functions as a pointer aiming at the code to be read The reading phase starts only when the trigger is pressed In this mode the reader is automatically set to trigger active level and one read per cycle parameters Only for Hand Held Operation e Automatic the illuminator is switched ON when the reader sees a code The reading phase starts automatically e Always ON the illuminator laser is always ON and the reader always ready for code reading 4 42 Hardware Trigger Signal This parameter determines how the reader ON state is controlled for readers with button trigger when Hardware Trigger is selected e trigger level the reader goes ON when the trigger is pressed and goes OFF when it is released e trigger pulse the reader goes ON at the first trigger press and goes OFF only at a second press 4 4 5 Trigger Off Timeout When this timeout is selected the reader turns OFF automatically a
67. t Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 seconds delay disabled 17 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VALLA USB KBD VAN CONTROL CHARACTER EMULATION Shift Key CTRL Key 18 Delfi TECHNOLOGIES RS232 PARAMETERS BAUD RATE PARITY DATA BITS STOP BITS HANDSHAKING ACK NACK PROTOCOL FIFO INTER CHARACTER DELAY TIMEOUT SERIAL TRIGGER LOCK 09 09 09 1 e Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and follow the procedure given Default value 3 Read the Exit and Save Configuration code ONCE available at the top of each page 19 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration RS232 VGA BAUD RATE 300 baud 600 1200 baud 2400 baud 4800 baud III 9600 baud 19200 baud 38400 20 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VALLA RS232 VAN PARITY none even parity odd parity DATA BITS 7 bits 8 bits
68. ta meets certain criteria which you will define in the following procedure Up to 4 advanced code management formats can be defined and saved in memory For each format you must complete the entire configuration procedure Read the Enter Configuration Command Step 1 Begin Format Definition 1 2 3 0r4 Steps 2 4 Define Match Code Conditions Step 5 Divide Code into Fields Step 6 Define Code Fields Steps 7 8 Add up to 2 Additional Fields Step 9 Define Field Transmission Step10 Apply or Not Standard Message Formatting L Step11 End Format Definition 1 2 3 or4 YES Define another NO Enable Advanced Formats 1 2 3 4 l L Define No Match Result I Read the Exitand Save Configuration Command 90 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration s ADvaNceDFormarrinc 1 Begin Format Definition begin Format 1 definition a begin Format 2 definition begin Format 3 definition begin Format 4 definition 2 Match Code match code type Read the above code the code type to match from the Code Identifier Table Appendix any code type 3 Match Code Length
69. th no character that is it will be removed from the code 49 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration DATA FORMAT TDI LLL Example The following strings define 1 First Character Replacement substitution in Code 39 barcodes of all occurrences of the 0 character with the 1 character 2 Second Character Replacement substitution in Code 39 barcodes of all occurrences of the A character with the B character first character replacement Code 39 ASCII characters corresponding to ASCII characters corresponding to the HEX value for character 0 the HEX value for character 1 t 30 31 For Code 39 codes containing the string 0123 the contents transmitted will be 1123 second character Code 39 ASCII characters corresponding to ASCII characters corresponding to replacement the HEX value for character A the HEX value for character B For Code 39 codes containing the string ABCD the contents transmitted will be BBCD 41 42 50 Delfi TECHNOLOGIES POWER SAVE SCAN RATE SLEEP STATE USB SUSPEND ENTER SLEEP TIMEOUT STANDBY 1 e Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and follow the procedure given Default value 3 Read the Exit and Save Configur
70. the FIFO buffering is disabled each code must be transmitted before another one can be read 4 14 RXTimeout When the RS232 interface is selected the Host can be used to configure the device by sending it command strings see appendix A This parameter can be used to automatically end data reception from the Host after the specified period of time If no character is received from the Host after the timeout expires any incomplete string any string not terminated by lt CR gt is flushed from the device buffer 106 Delfi TECHNOLOGIES REFERENCES 4 2 PEN PARAMETERS 4 2 1 Minimum Output Pulse This parameter sets the duration of the output pulse corresponding to the narrowest element in the barcode In this way the code resolution is controlled by the signal sent to the decoder independently of the physical resolution of the code read The shortest pulse 200 us corresponds to high resolution code emulation and therefore shorter transfer speed to the decoder for decoders able to work on high resolution codes Likewise longer pulses correspond to low resolution code emulation and therefore a longer transfer time to the decoder 4 2 2 Conversion to Code 39 When using these readers it is possible to convert all codes to Code 39 By disabling this option the decoded codes will be transmitted in their original format except for the following codes which are ALWAYS converted into Code 39 format MSI Plessey Telepen
71. the stacked version of these codes simply move the reader over the code so that each line the code is scanned 85 Delfi TECHNOLOGIES ADVANCED FORMATTING CONCATENATION ADVANCED FORMATTING Please follow the setup procedure carefully for these parameters 1 e Read the Enter Configuration code ONCE available at the top of page 2 e Read configuration codes precisely following the numbered procedure given Read the code and follow the procedure given Default value 3 e Read the Exit and Save Configuration code ONCE available at the top of page 86 Delfi Exit and Save Configuration Enter Configuration ADVANCED FORMATTING CONCATENATION disable enable Permits the concatenation of two codes defined by code type and length It is possible to set a timeout for the second code reading and to define code transmission if the timeout expires The order of transmission is CODE 1 CODE 2 Define Concatenation 1 Code 1 code ID 1 Read the code type from the Code Identifier Table beginning Appendix code length Read a number in the range 01 99 from the Hex Numeric Table 87 TECHNOLOGIES Delfi TECHNOLOGIES Exit and Save Configuration ADVANCED FORMATTING 2 Code 2 code ID Read the code type from the Code Identifier Table beginning Appen
72. ty parameter is effective for all operating conditions described in par 1 1 58 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VE READING PARAMETERS VAN BEEPER TONE tone 1 tone 2 tone 3 tone 4 monotone bitonal BEEPER LENGTH long short Goop READ SPOT DURATION CCD Long Range Readers ONLY disable short 59 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VETA READING PARAMETERS VGA medium lon g STAND RECOGNITION BEEP ONLY Readers with Stand Recognition disable enable 60 Delfi TECHNOLOGIES Enter Configuration Exit and Save Configuration VE READING PARAMETERS VAN AUTOMATIC OPERATION IMING LIGHT CCD Long Range Readers ONLY disable enable See par 4 4 6 for details AIMING SYSTEM Laser Readers ONLY disable 300 ms 500 ms 1 5 See par 4 4 7 for details 61 Delfi TECHNOLOGIES DECODING PARAMETERS INK SPREAD OVERFLOW CONTROL INTERDIGIT CONTROL DECODING SAFETY PUZZLE SOLVER AN Before changing these parameter values read the descriptions in par 4 5 CAUTION 1 e Read the Enter Configuration code ONCE
73. ull ASCII nocheckdigitcontrol check digit control and transmission 22 check digit control without transmission AB2 cs gt Code32 A code length AB xxxx disable Code 2 5 family A Interleaved 2 5 no check digit control 11 check digit control transmission AC1 check digit control without transmission AC13xxxx Normal 2 5 5 bars no check digit control AC21x check digit control and transmission 22 check digit control without transmission 23 Industrial 2 5 IATA check digit control 1 check digit control transmission AC3 check digit control without transmission AC33x Matrix 2 5 3 bars no check digit control 41 check digit control and transmission ACA check digit control without transmission CIP HR A XXXX ASCII numbers that define the code length where First 2 digits minimum acceptable code length e Second 2 digits maximum acceptable code length The minimum code length must always be less than or equal to the maximum The maximum code lengths are 99 characters Examples 0132 variable length from 1 to 32 digits in the code 1010 10 digit code length only 129 Delfi TECHNOLOGIES DELFISCAN C80 CODE SELECTION continued DESCRIPTION STRING Codabar disable Codabar family Apo nor transmission pee but transmission but no transmission start stop character equality
74. x Numeric check no tx Alpha no check Alpha check with tx Alpha check no tx Delta IBM disable the family Type 1 check Type 2 check Code 11 disable the family no check Type C with tx AG21 Type C no tx AG22 Type K with tx AG31 Type K no tx AG32 Type C and K with tx AG41 Type C and K no tx AG42 Code 16K disable AJO Code 49 disable AM0 AQ0 RSS Codes disable the family disable RSS Expanded Linear and Stacked enable RSS Expanded Linear and Stacked disable RSS Limited enable RSS Limited disable RSS 14 Linear and Stacked enable RSS 14 Linear and Stacked B CODE IDENTIFIER TABLE 2 5 Interleaved 2 5 Industrial 131 Delfi TECHNOLOGIES DELFISCAN C80 JUL 2 5 normal 5 bars 2 5 matrix 3 bars 8 13 III UPCA UPCE HL EAN 8 with 2 ADD ON EAN 8 with 5 ADD ON ATL EAN 13 with 2 ADD ON EAN 13 with 5 ADD ON UPCA with 2 ADD ON UPC A with 5 ADD HAN UPC E with 2 ADD ON UPCE with 5 ADD ON Code 39 MUNIN Code 39 Full ASCII LLL CODABAR Delfi TECHNOLOGIES CODABAR 128 128 Ill ISBT 128 CIP HR HE CIP 39 32 Code 93 MSI MUU Plessey Standard Plessey