1. STEP 5 Push cable and switch housing into the hole firmly STEP 6 Diagram 5 Firmly connect the Plug amp Play connector to the steam generator connector B NOTE The connector is keyed and will only connect in one orientation DIAGRAM 5 26 mr steam stea tempo controls Installing the Remote Temperature Probe for Tempo amp Tempo Plus Controls en sts The Remote Temperature Probe is required when the TEMPO or TEMPO PLUS Controls are installed outside the steam room The Remote Temperature Probe P N MSTS is for use MJ with TEMPO and TEMPO PLUS Controls only Do not use any other controls Do not use any other temperature probe with the TEMPO and TEMPO PLUS controls Noncompatible products may result in an inoperative control and a hazardous condition Install the TEMPO or TEMPO PLUS Controls according to the installation and operation instructions supplied with the Controls Failure to do so may result in an inoperative control and a hazardous condi tion 1 Determine the location of the Remote Temperature Probe The Remote Temperature Probe must be installed 1 On a vertical surface 2 4 5 feet above the floor 3 Away from the steam head 4 Not exposed to direct steam emission The probe has an integral 30 cable Insure that the probe and or steam generator are located accord ingly Contact a Mr Steam technical service repre sentative if a longer cable is required Drill a 5 1
2. 6 No heating venting or air conditioning devices should be installed inside the steam room 7 Steam room construction information is available from the Tile Council of America Inc by purchasing the TCA Handbook for Ceramic Tile Installation Tel 864 646 8453 or www tileusa com 8 Windows that are part of the steamroom should be double paned 9 Try to limit steamroom ceiling height to 8 feet Exceeding 8 feet may require a higher rated steam generator PAR WARN UL KS The MS series of steam generators are for residential use only Commercial or other nonresidential applications void the warranty and may adversely affect product performance 1 Children under the age of 16 should not use the Steambath 2 Check with a physician before use of the Steambath if you are pregnant have a coronary condition are in poor health are being treated for any other medical condition or are using medication or drugs 3 Exit Steam Room immediately if you feel faint dizzy sleepy or otherwise uncomfortable 4 Do not use the Steambath if you have recently consumed alcohol 5 Condensation and moisture may cause the the Steambath floor and other surfaces to become slippery and dangerous Installation of non skid floor materials or the use of proper footwear is recommended at all times IMPORTANT Read the manual provided for use and safety information 2 mr ste am s K Installation Operation amp Maintenance Manual Locating the St
3. If the control times out not manually turned off then the previous user time and tem perature settings will be used when the steambath is used again PROG 1 and PROG 2 Feature PROG 1 and PROG 2 keys program and store preferred settings To program preferred settings Press a PROG1 or PROG2 key Enter the preferred time and temperature settings The TEMPO PLUS will store these settings To select PROG1 or PROG2 Press ON then press PROG or PROG2 The steambath will begin to operate at the stored settings 22 tempo controls DIAGRAM 1 DIAGRAM 3 DIAGRAM 4 mr steam steamthera py tempo controls Tempo Remote Wireless Remote Control Box Contents The TEMPO REMOTE Control operates all functions of the TEMPO PLUS TEMPO REMOTE Control Control from a maximum distance of about 15 feet It is for use inside the steam room and requires a direct line of sight with the TEMPO PLUS Control The TEMPO REMOTE does not operate with the TEMPO Control To operate the TEMPO REMOTE simply point it at the TEMPO PLUS Control and press the desired function Control Holder 2 Holder Screws User s Manual Dimensional Information for Tempo Remote 1 Programming the Code The TEMPO Remote control is supplied with two AAA batteries already installed If these batteries have been removed for more than 3 minutes or are discharged then the TEMPO Remote code must be re entered 1 Press SETUP key 3 While holding
4. TEMPO PLUS CONTACTOR ME Pd WHITE HH ff TEMPO EXT ze optional d M AUTOFLUSH ETE optional FEED CONTROL BOARD d SOLENOID ELEMENT VALVE POWER INPUT G I TRANSFORMER BLACK WHITE BLACK E E BLUE gt PURPLE GROUND HH Wiifrt TO PROBE gs AA A EH CONTACTOR mer B white HH il GRAY i E AUTOFLUSH optional WATER FEED CONTROL BOARD d SOLENOID ELEMENT VALVE mr ste am Installation Operation amp Maintenance Manual Three Phase Wiring Diagram with Tempo Plus Control Installation Instructions for Models MS Super 4T MS Super 5T and MS Super 6T 1 Install each unit as in a single installation as close to each other as possible 2 IMPORTANT Power must be disconnected at the main electrical supply Remove steam generator covers 3 Connect the TEMPO PLUS control to either unit per instructions supplied with the TEMPO PLUS control 4 Remove one knock out on each generator as shown Insert the ends of interconnecting cable provided PN 103904 through the knock outs as shown in diagram A page 4 Connect each end to the printed circuit board as shown 5 Connect separate plumbing and power supplies for each unit Wiring Diagram MS Super 4T MS Super 5T MS Super 6T Three Phase Models POWER INPUT LEGEND Al Diagrams 1 02 13 G FIELD Leal pack TRANSFORMER wye WIRING WIRING L s BLACK E E DARK i FACTORY PURPLE TO PROBE HH M Hl CABLE Dl TEMP
5. PROG 1 key 5 The indicator will shut off if the press CODE key for two sec code is correct and the setting was onds until the indicator lights successful If not the indicator will up Then release both keys flash twice Check the code and repeat the programming process if necessary 2 Press and hold PROG 1 key The indicator will flash NOTE The remote control will exit programming mode if any other keys but the numerical ones 1 2 3 4 are pressed 4 Enter the s digit Code No 11433 NOTE Delays longer than 10 sec onds between key presses automati cally cancels programming mode 23 mr steam steamthera py tempo controls Using the Tempo Remote To Control Your Tempo Plus with the Remote Control ON OFF SETUP PAUSE Turning Unit ON OFF Setting Temperature Set Point 1 Press ON OFF key to turn unit on Press the TEMP UP or TEMP DOWN key 2 Press ON OFF key a second time to turn unit off Setting Duration Time Press TIME UP or TIME DOWN key Pausing the Unit To Pause the Flow of Steam 1 Press PAUSE key NOTE The Timer continues to count down while in the PAUSE mode 2 Press PAUSE key a second time to resume the flow of steam Setting the Program Values To Set PROG 1 and PROG 2 1 Press PROG 1 or PROG 2 key 2 Press TEMP UP or TEMP DOWN key to set the desired temperature 3 Press TIME UP or TIME DOWN key to set the desired duration time mr steam steamthera py t
6. contacting hot surfaces such as steam outlet safety valve and the like 6 Connect separate plumbing and power supplies for each unit Replace covers with cover screws enlarged for illustrative Interconnecting Cable PN 103904 NOTE FOR ILLUSTRATIVE PURPOSES ONLY Units shown prior to plumbing and installation Diagram B Assembled and Installed MS Super 4T 5T 6T Typical Installation shown with Optional AutoFlush Provide unions as required to facilitate installation and disconnection of piping Secondary Unit E Optional AutoFlush see TEMPO PLUS Control Steam Heads AutoFlush Installation page 13 NOTE For illustrative purposes only Consult with qualified designer architect or contractor for steam room construction details mr steam Installation Plumbing All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable National and local codes Use unions on all pipe connections Use only brass piping or copper tubing as permitted by codes Do not use black galvanized or PVC pipe Water Supply NPT 1 Connect hot or cold water line Hot water line is preferable however hot water should not exceed 160 F 2 Provide a shut off valve in the water supply line upstream of the steambath generator 3 Do not overheat inlet solenoid valve with solder connections Overheating will damage parts 4 Flush inlet water line tho
7. or a plug at safety valve outlet DO NOT connect a shut off valve in steam supply pipe Enjoy AromaSteam essential oils by placing a drop or two into your AromaSteam steamhead as show n in the illustration Only use Mr Steam AromaSteam essential oils in a Mr Steam AromaSteam steamhead EYE Use essential oils with caution Essential oils are for external use only Keep out of reach of children Essential oils are highly con centrated and are potent substances and should not be applied directly to the skin as they can be irritants Use essential oils with caution NNER Place the drops into the Mr steam AromaSteam steamhead recess prior to turning on the steambath Do not place drops in a hot steam head as SERIOUS INJURY CAN RESULT IF YOU DO NOT FOLLOW THIS WARNINC ELT Start with one drop to gauge strength and suitability Limit to a maximum of a few drops during a steambathing session TUI Some people may find that the aroma makes them dizzy and the user should exit the steam bath IMMEDIATELY If skin irritation occurs stop using the oils immediately Remove any excess oil by washing in mild soap and water If ingested rinse mouth with water Administer water or milk to dilute Contact a physician immediately Tightly close containers when storing oils Keep away from sources of ignition AromaSteam 10ml bottle with integrated dropper Recess for essential oil Aromasteam steam head install p
8. 101289 9 3 07
9. 6 inch diameter hole in the wall as shown in Diagram 1 Do not oversize or undersize the hole Clean area thoroughly Remove the knock out from the steam generator jacket as shown in Diagram 2 Insert the remote temperature probe cable through the knock out and connect to the connector onthe steam generator printed circuit board marked TEMP PROBE as shown in Diagram 2 NOTE FOR ILLUSTRATIVE PURPOSES ONLY Consult with qualified designer architect or contractor for steam room construction details DRAWING NOT TO SCALE aad Le 7 ne DIAGRAM 1 Printed Circuit Board Component shown for illustrative purpose Pii No Temperature Probe EE NES Connection Knock Out xd Temperature Sensing Probe Ma S Probe Cable 30 feet MrSteam Steam Generator shown with cover removed and NOT installed DIAGRAM 2 27 mr steam tempo controls Installing the Remote Temperature Probe cont 5 Route the end of the temperature probe cable with the temperature probe through the wall into the steam room as shown in Diagram 3 IMPORTANT NOTE Do not strain staple pinch or otherwise damage the probe cable 6 With a minimal length of the cable exposed apply silicone provided to the hole in the wall as required to create a moisture seal as shown in Diagram 3 7 Push the temperature cable and bulb into hole as required to leave minimum 1 4 maximum 1 2 of the bulb exposed as shown
10. AutoFlush valve end B to the Drain Valve valve end A and B are indicated on bottom of AutoFlush Valve DO NOT REMOVE THE DRAIN VALVE Removal may cause equipment and property damage If there is not enough room for the valve an elbow and a short nipple not provided can be added Nipple copper or brass nipple 1 2 NPT x 3 1 2 or longer not supplied Drain Valve shown in the correct open position DO NOT REMOVE THIS DRAIN VALVE End B End 4 Open Drain Valve handle must be aligned with brass nipple as shown 5 Connect the AutoFlush cord connector to the two pin con nector C as shown JAR Warn UDKA Do not drain into a steam enclosure or any location where accidental contact with drain water may occur In the event of a power failure the Autoflush valve will open and dis charge hot water Steam Generator DO NOT TURN OR REMOVE THE DRAIN VALVE Sweat Fittings When using sweat fittings use only tin base solder with a melting point below 600 degrees F Do not overheat Ends of water supply tubing must be thoroughly cleaned for a minimum distance of 1 from ends Do not remove valve cover To Check Operation 1 Turn on Mr Steam and allow tank to fill with water see Mr Steam instruction manual 2 Turn off Mr Steam control Water should stay in tank 3 Turn off power at the panel box Water should discharge from tank 4 Turn on power at panel box 5 Repeat PROVIDE DRAIN PLUMB
11. HASE MS SUPER 1T MS SUPER 2T MS SUPER 3T TEMPO or Es TEMPO PLUS CONTROL fs TEMPO EXT optional AUTOFLUSH optional CONTROL BOARD HEATING SOLENOID ELEMENT VALVE TRANSFORMER WHITE THREE PHASE MS 65T MS 90T MS 150T MS 225T MS 300T MS 400T MS SUPER 1T MS SUPER 2T MS SUPER 3T TEMPO or E TEMPO PLUS CONTROL 3 TEMPO EXT optional 3 AUTOFLUSH optional CONTROL BOARD HEATING SOLENOID ELEMENT VALVE mr ste am Installation Operation amp Maintenance Manual Single Phase Wiring Diagram with Tempo Plus Controls Installation Instructions for Models MS Super 4T MS Super 5T and MS Super 6T 1 Install each unit as in a single installation as close to each other as possible 2 IMPORTANT Power must be disconnected at the main electrical supply Remove steam generator covers 3 Connect the TEMPO PLUS control to either unit per instructions supplied with the TEMPO PLUS control 4 Remove one knock out on each generator as shown Insert the ends of interconnecting cable provided PN 103904 through the knock outs as shown in diagram A page 4 Connect each end to the printed circuit board as shown 5 Connect separate plumbing and power supplies for each unit Wiring Diagram MS Super 4T MS Super 5T MS Super 6T Single Phase Models POWER INPUT l c FIELD TRANSFORMER Wyre O WIRING FACTORY WIRING PURPLE TO PROBE n CABLE oe BLUE 1 i
12. ING ACCORDING TO LOCAL CODES PLUMB AS REQUIRED FOR GRAVITY DRAIN SYSTEM 13 Drain Valve Nipple Arrow indicates correct direction of flow Plumb to Drain Line in accordance with Code UU AutoFlush y Plumb to Drain Line mr steam 3LCalIlIULI ICI dap Installation Operation amp Maintenance Manual Liquid Level Control Board Explaination of LED Indicators With TEMPO or TEMPO PLUS control OFF Dry 75 Min 5V Water level indicator LED is ON when no water is detected for more that 5 seconds OFF when water level is satisfactory For units with AutoFlush if more that two hours have elapsed since last usage and this LED is OFF it is indicative of an autoflush or water level probe circuit malfunction LED is ON when 75 minute time out feature is active 5 VDC indicator LED is ON when there is 208 240 Volt incoming power connected 24 Volt transformer secondary output and on board 5 Volt DC control power are present With TEMPO or TEMPO PLUS control ON HTR RLY WTR RLY FLUSH RLY HTR Liquid Level Control Board PN 103899 tho I shown without wiring Room temperature status indicator LED is ON when control is calling for heat OFF when temperature is satisfied or PAUSE button is engaged Water feed solenoid relay indicator LED is ON when relay is closed and sending 24 Volts to the water feed solenoid valve coil OFF when water level is satisfied and relay is open AutoFlush r
13. O PLUS CABLE TEMPO EXT S HH i optional optiona 4 li CONTROL BOARD HEATING SOLENOID ELEMENT VALVE m POWER INPUT Ll 12 13 G BLACK TRANSFORMER wire H DARK BLACK 3 m BLUE PURPLE i TO PROBE HH O O CABLE il m CABLE HH E Eb i B AUTOFLUSH optional WATER Oar FEED CONTROL BOARD HEATING SOLENOID VALVE ELEMENT 11 mr steam Installation Operation amp Maintenance Manual Optional Tandem Cable for connecting 2 5 steam generators in tandem POWER INPUT 3 4 OR 5 MR STEAM UNITS u 12 FIELD WIRING INED MASTER UNIT FACTORY ale E WIRING l 4 I xk av PLUG THIS END TO MASTER UNIT Ba ro PURPLE H n PROBE HH Bi Tempo Control ili E Tempo Pius Control HH i Tempo Ext iH E AutoFlush El ET UND WHITE LIGHT BLUE CONTACTOR H ro Ho ro 04 od Fo bo f WHITE GRAY WATER FEED SOLENOID CONTROL BOARD HEATING ELEMENT OPTIONAL TANDEM CABLE FOR 2 5 GENERATORS Length is 30 ft PN 103917 POWER INPUT ul 12 uo ME SECOND UNIT DARK BAK BLUE ill H PURPLE H i TO PROBE HE Ei li i i 3 AutoFlush TO THIRD UNIT TO FOURTH UNIT T TO FIFTH UNI
14. Residential Steambath Generator Systems Installation Operation amp Maintenance Manual mr steam steamtherapy Residential Steambath Generator Systems Installation Operation amp Maintenance Manual MODEL Serial No MODELS MS 65T MS goT MS 150T MS 225T MS 300T MS 400T MS SUPER 1T MS SUPER 2T MS SUPER 3T MS SUPER 4T MS SUPER 5T MS SUPER 6T IMPORTANT NOTE As you follow these instructions you will notice warning and caution sym bols This blocked information is important for the safe and efficient installation and operation of this generator These are types of potential hazards that may occur during this installation and operation WARNIN JN AUTION states a hazard may cause signals a situation where This highlights information serious injury or death if minor injury or product damage that is especially relevant to a precautions are not followed may occur if you do not follow problem free installation instructions All information in these instructions is based on the latest product information available at the time of publica tion Sussman Automatic Corporation reserves the right to make changes at any time without notice mr steam 43 20 34th Street 9410 S La Cienega Blvd Sussman Automatic Corp Long Island City NY 11101 Inglewood CA 90301 info mrsteam com Tel 1 800 76 STEAM Tel 1 800 72 STEAM www mrsteam com Fax 718 472 3256 Fax 310 216 2944 mr steam i Pn up C uS g LISTED M
15. Super IT MS Super 6T with AutoFlush shown with cover removed Power Block Power Supply Knock Out Liquid Level Probe Access Cover NOTE FOR ILLUSTRATIVE PURPOSES ONLY Some components may be omitted or altered for clarity Do not use for wiring repair or other purposes not related to component identification Heating Element zaf ye a OID ID B Stainless Steel Tank 16 We a TE JAT t p SR B n amus e 4 l j Liquid Level Control Board Data Plate requ with NOTE valve shown in open position as Transformer Water Feed Solenoid Plug and Play Connection see page 14 Water Feed Steam Outlet Safety Valve gt Water Feed Hose AutoFlush Valve optional Drain Line ired for operation autoflush mr steam Replacement Parts List Installation Operation amp Maintenance Manual Part No Description Product 99178 Drain Valve MS SuperaT Super 6T 99178MS Drain Valve MS 65T MS 4ooT 99297 Safety Valve 15PSI All models 100479 Water Feed Solenoid Valve w filter All models 100477 1 Transformer 24VAC All models 103899 Liquid Level Control Board All models 103904 Tandem Cable for 2 generators 12 ft All models 103917 Tandem Cable for up to 5 generators 30 ft All Models 103905 Cable for Tempo Control 30 ft All models 103922 Cable for Tempo C
16. T es CONTACTOR 8 vint o GRAY WATER FEED M SOLENOID CONTROL BOARD VALVE Initial Start Up and Checkout 1 Turn on control Follow specific instruction sheet provided with controls 2 Steam will begin to appear in 5 minutes at the steam head Steam will shut off when desired temperature is reached and will automatically resume when room temperature drops below set point 3 Steam will shut off automatically when control counts down to zero To shut steam off manually turn control OFF To clear steam from enclosure area turn shower on before opening door 4 If unit does not start and control does not turn ON control display does not light up then turn breaker off for 20 seconds and try again Optional Equipment Refer to specific instruction sheets for installation operation and maintenance of optional equipment and accessories such as TEMPO TEMPO PLUS TEMPO EXT MSTS Maintenance Mr Steam steambath generators require little maintenance Other than periodic draining maintenance procedures are minimal Every 2 months or more often in hard water areas the manual drain valve should be opened fully flushing out accumulated materials salts and other particles which are natural by products of boiling water NOTE Flush a minimum of five hours after the control has been turned off to insure that th
17. TEMPO or TEMPO PLUS control A The TEMPO EXT control functions as an external ON OFF switch for the TEMPO or TEMPO PLUS control Box Contents Tempo Ext Control 1 l A Vg User s Manual I ED Using the Tempo Ext Control This TEMPO EXT control functions as an ON OFF key of the TEMPO or TEMPO PLUS control of your system LED indicator will light up when the generator is ON Installing the Tempo Ext Control 3 XD Diagram 1 gar The TEMPO EXT has a 30 foot cable with a Plug amp Play connector at one PLUG amp PLAY end and an ON OFF switch at the other end Contact a Mr Steam technical CONNECTOR service representative if a longer cable is required STEP 1 Diagram 2 Drill a 7 8 inch diameter hole in a wall location outside the steam room Do not oversize or undersize the hole Route the cable from the wall to the steam generator Do not strain staple pinch or otherwise damage the control cable P DIAGRAM 2 STEP 3 Diagram 3 Remove and discard the peel off paper from the switch housing to expose the adhesive as shown in Diagram 4 ve So STEP 4 Diagram 4 Gr A Apply silicone provided with TEMPO or TEMPO PLUS control to the lt hole in the wall as required to create a moisture seal Apply silicone DIAGRAM 3 to the back of the switch as required to seal grout lines or as required for additional adhesion IMPORTANT Use care not to apply silicone to the adhesive gasket
18. a pause in steam flow is desired press the PAUSE key The display will flash while the control is in the PAUSE mode The timer will continue to countdown while in the PAUSE mode Setting the Time Duration Diagram 3 Press TIME key to set or display the remaining relaxation time The control is pre set and will display a TIME setting of 20 minutes default setting With the TIME displayed press the UP and DOWN keys Diagram 4 to set the desired duration time 2 60 minutes in two minute increments Set the steambathing duration according to personal preference however it is highly recommended to begin steambathing at a shorter duration to gauge comfort and safety levels The control will turn off when the relaxation period times out Setting the Temperature Press TEMP key to set the desired temperature or display the temperature setting The control is pre set and will display a temperature setting of 110 F default set ting With the temperature displayed press the UP and DOWN keys Diagram 4 to set the desired temperature 105 F to 120 F in one degree increments Set the steambathing temperature according to personal preference however it is highly recommended to begin steambathing at a low temperature setting to gauge comfort and safety levels Memory Feature If the control is turned off manually before it times out then the default settings of 20 minutes and 110 F will be used the next time the control is turned on
19. al size of the unit clearance for plumbing servicing and its distance from the steam room must all be consid ered before final installation IMPORTANT MrSteam units are intended to be operated with MrSteam TEMPO PLUS TEMPO TEMPO REMOTE and TEMPO EXT Controls only and are to be installed strictly in accordance with the specific instructions contained in this manu al and as supplied in the manuals provided with the controls ELECTRICAL SHOCK HAZARD MrSteam steam generators are connected to 240V line voltage and contain live electrical components All installation and service to be performed by qualified and licensed electricians and plumbers only Installation or service by unqualified persons may void the warranty Steam Room Guidelines 1 Steam room must be completely enclosed with full walls door floor and ceiling 2 It is recommended that a gasketed door is used for heat sealing and steam containment 3 If tile type or other smooth surfaced flooring is used provide suitable anti skid strips or equivalent to prevent user slipping and injury 4 Walls and ceilings must be constructed of water resistant non corrosive surface such as tile marble molded acrylic or other non porous material The ceiling should be sloped to prevent dripping of condensate If acrylic fiberglass or other non heat resistant materials are used as part of the steamroom enclosure see pg 6 Steamhead for additional details 5 Provide a floor drain
20. allation Instructions for Tempo amp r Tempo Plus IMPORTANT READ BEFORE LOCATING THE CONTROL DO NOT LOCATE THE CONTROL NEAR OR ABOVE THE STEAMHEAD AS THIS MAY CAUSE DIRECT STEAM EMISSION TO INTERFERE WITH STEAMROOM TEMPERATURE REGULATION BOX CONTENTS TEMPO or TEMPO PLUS Control Control Cable 30 ft Steam Head Tube of Silicon Sealant Owner s Manual The TEMPO and TEMPOJ Plus controls are 3 diameter and 7s deep Step I Determine the desired installation location of the control The TEMPO and TEMPO Plus controls are designed to be installed inside or outside the steam room as a matter of personal preference If the control is installed inside the steamroom the control must be located 4 5 feet above the floor i py DIAGRAM away from the steamhead and not exposed to direct steam emission AGRA on a vertical wall The control cable length is 30 feet Insure that the control and or steam generator are located accordingly Contact a Mr Steam technical service representative if a longer cable is required If the control is installed outside the steam room a Remote Temperature Probe Part Number MSTS must be installed inside the steam room Insure Mr Steam steam generator is TEMPO compatible and has a serial numbeR 355500 or higher IMPORTANT See installation instructions supplied with the tempera ture Probe before rough in or installation of the control Step 2 Make a one inch diamet
21. an and dry as required for good adhesion Apply silicone into the hole in the wall as required to create a moisture seal Hold the control with the LED display in the 12 o clock posi tion and press the control against the wall until the adhe sive sticks and holds firmly as shown in Diagram 5 IMPORTANT Two registration marks are provided to facilitate level installation The marks are located at the 3 o clock and 6 o clock positions on the back side of the con trol Use a level as required 20 DIAGRAM 3 DIAGRAM 4 DIAGRAM 5 mr steam steamthera py tempo controls Tempo Operating Instructions The TEMPO Control features programmable digital temperature control a fixed 60 minute duration ON OFF and PAUSE ON OFF Diagram 1 Press the ON OFF key to start or stop the flow of steam Steam will begin to flow a few minutes after the control is turned ON The duration required for the steamroom to reach steambathing tem peratures depends on the steamroom construction and steam generator specifications Steam may continue to flow for a short time after the control is turned OFF PAUSE feature Diagram 2 If a pause in steam flow is desired press the PAUSE key The display will flash while the control is in the PAUSE mode The timer will continue to countdown while in the PAUSE mode DIAGRAM 1 Setting the Temperature Diagram 3 The control is pre set and will display the temperature setting of 110F default se
22. appropriate model Visit www mrsteam com for sizing and selection calculators and additional information IMPORTANT The formula for selecting the steambath generator is a recommendation only Because of variables in construction these sizing instructions and specifications should be considered as guidelines only Mr Steam will review the model selected provided we receive complete information including working drawings specifications and pertinent electrical and construction details Otherwise the manufacturer disclaims responsibility for the sizing of a model selected Model No MS 65T MS goT MS 150T MS 225T MS 300T MS 400T MS Super 1T MS Super 2T MS Super 3T MS Super 4T MS Super 5T MS Super 6T Kw 4 5 75 8 5 10 12 15 20 24 30 Selection Chart Max Room Vol cu ft 65 100 175 250 325 375 475 575 675 875 1075 1275 Available Voltage 50 60 HZ 208V 1PH 240V 1PH 208V 1PH 240V 1PH 208V 1PH 240V 1PH 208V 1PH 240V 1PH 208V 1PH 240V 1PH 208V 1PH 240V 1PH 208V 1PH 240V 1PH 208V 1PH 240V 1PH 208V 1PH 240V 1PH 208V 1PH 240V 1PH 208V 1PH 240V 1PH 208V 1PH 240V 1PH Amps 22 19 24 21 29 25 36 32 41 36 44 38 49 42 58 50 73 63 97 84 116 100 145 125 15 Models MS TEMPO or 65T MS 4ooT are compatible with TEMPO PLUS Controls and include a matching AromaSteam steam head All SUPER Models supplied standard wit
23. below Steam Room Interior Diagram 3 PAR WARN ULES Insure a minimum of 1 4 of the temperature bulb is exposed to the air Failure to do so may result in an inoperative control and a hazardous condition The exposed area of the temperature bulb must be free ee of silicone or any materials that prevent direct exposure to the steam room air Failure to do so may interfere with the ability to sense temperature and may result in excessive steam room temperatures P Diagram 4 HEY RAA A h p n ee I V4 Minimum Go e Ss Yo Maximum TZIZ y HAHA SA e l l l Silicone Sealant J 7 INSTALLED REMOTE SECTIONAL VIEW TEMPERATURE PROBE 28 mr steam Sussman Automatic Corporation info mrsteam com www mrsteam com 43 20 34th Street 9410 S La Cienega Blvd Long Island City NY 11101 Inglewood CA 90301 Tel 718 937 4500 Fax 718 472 3256 Tel 310 216 6565 Fax 310 216 2944 2007 Sussman Automatic Corporation mr steam steamtherapy MR STEAM and des A LIFETIME OF PLEASURE ALLEGRO AROMAFLO AUTOFLUSH CLEAN STEAM EVER TIME MRSAUNA STEAM ON DEMAND STEAM HOME SUSSMAN SUSSMAN LIFESTYLE GROUP TEMPO TEMPO PLUS TEMPO REMOTE TEMPO EXT and WARMATOWEL are registered trademarks of Sussman Automatic Corporation AROMASTEAM CLUB THERAPY CHROMASTEAM Fi PLUS MUSICTHERAPY SAUNA ONE and STEAMTHERAPY are trademarks of Sussman Automatic Corporation PUR
24. e the portion that was in the wall the end to your mark Subtract Y from that dimension and select a brass nipple of that length to finish the installation STEP 5 Wrap teflon tape around the threads of the new nipple and screw the nipple into the steamhead Do not use wrenches or tools which would damage the steamhead s finish Wrap teflon tape around the threads of the nipple and screw the nipple and steamhead assembly you just made into the drop ear fitting in the wall The steamhead should be flush with the wall and the well must be facing up Oil Well Installation Operation amp Maintenance Manual 7 1 8 minimum clearance e required when Acrylic Shield is used See installation instructions provided with the Acrylic Shield Use Teflon or equal sealant on pipe threads s Steam Supply Pipe Apply with silicone or equal sealant as required for moisture seal End of pipe to be recessed lt lt 1 4 without Acrylic Shield 1 8 with Acrylic Shield STEP 3 STEP 4 mr steam Generator Diagram 4 Water Inlet Installation Operation amp Maintenance Manual w ES Control amp Accessory Connections p 1 I Optional AutoFlush I i i Manual Drain Valve I IMPORTANT NOTE Provide a minimum of 12 inches at both ends and top of the steam generator or as requi
25. e water has cooled Draining immediately after a steam cycle may expose PVC and other piping to high temperature water Check local codes The unit will refill automatically when the control is activated again In areas of hard water a Mr Steam autoflush system is recommended for generator longevity 12 mr steam stea Optional AutoFlush 3 Pin Connector for Tempo Ext 2 P Box Contents for A 9 Pin Connector for Tempo and AutoFlush Valve with Cord Tempo Plus Controls Installation instructions Operation Installation Operation amp Maintenance Manual in Connector utoFlush The optional AutoFlush feature automatically drains the Mr Steam system following each use The stainless steel tank is flushed and remains empty until the steam generator is used again A time delay about five hours allows the water to cool down before it drains resulting in a safe and gentle operation Installation Instructions 1 Disconnect all power supplied to the unit Steam Genel 2 Plumbing to be performed by a gualified licensed plumber and shall be in accordance with applicable National and Local Codes Unit drains by gravity A drain line that is lower than the AutoFlush assembly must be avail able The AutoFlush valve outlet is threaded 1 2 NPT Check plumbing code for receptor trap and vent reguirements Use copper or brass nipple 1 2 NPT x 3 1 2 or longer not supplied to connect
26. eam Generator Unit Select a location as near as practical to the steam room Typical locations include closet vanity cabinet heated attic or basement NOTE THE STANDARD LENGTH OF THE CABLE FOR CONNECTING THE CONTROL TO THE STEAM GENERATOR IS 30 FEET THE STEAM GENERATOR AND CONTROL MUST BE LOCATED ACCORDINGLY A 60 FOOT CABLE PN 103922 IS AVAILABLE AS A SPECIAL ORDER PART JAR WARN DA ITEMS 1 7 1 Do not install steambath generator or plumbing lines in unheated attic or any locations where water could freeze 2 Do not install steambath generator inside steam room 3 Do not install steambath generator outdoors or wherever environmental conditions may affect the safety and or performance of the generator 4 Do not install steambath generator near flammable or corrosive materials or chemicals such as gasoline paint thinners or the like Installation in areas having high concentrations of chlorine such as pool equipment room must be avoided 5 Install steambath generator on a solid and level surface Keyhole slots are provided for wall mounting Insure the steam generator is properly secured and level when mounting with keyhole slots 6 Install steambath generator in an upright position only 7 Steam line safety valve drain valve plumbing and steamheads become hot during operation and remain hot after shutdown for a period of time Provide appropriate protection including insulating plumbing lines Avoid plumbing runs and st
27. eamhead locations that can come in contact with bathers IMPORTANT ITEMS 8 12 8 Locate steambath generator within 25 feet of steam room g Install anti water hammer device as necessary 10 Provide a minimum of 12 inches at both ends and top of the steam generator or as required for servicing See page 7 11 Provide unions as required to facilitate installation and disconnection of piping 12 Mr Steam controls can be located inside the steam room or on the outside of the steam room See separate CONTROL INSTALLATION AND OPERATION INSTRUCTIONS for specific details If the controls are located outside the steamroom a remote sensor part number MSTS is required see pages 19 28 NOTE Mr Steam Generators inclusive of the Tempo series Controls are CE and UL listed UL listing is for operation of the Tempo controls in wet environments AN wARN ULES The MS series of steam generators are for residential use only Commercial or other non residential applications void the warranty and may adversely affect product performance Use only Mr Steam Tempo series controls Typical Mr Steam Installation i E T TEMPO or TEMPO PLUS Control See page 19 for installation information NOTE FOR ILLUSTRATIVE PURPOSES ONLY Consult with qualified designer architect or contractor for steam room construction details Control cable Field installed power supply F
28. ed licensed VOL CU FT 1 PH AWG electrician in accordance with National Electrlcal Code MS 65T 65 4 5 208 22 10 and local electrical code 240 19 12 MS 90T 100 5 0 208 24 10 up s HI 240 21 10 Power Wiring See Field Power Wiring Diagrams below MS 150T 175 6 0 208 29 10 1 Check power voltage Use 240V rated unit when supply 240 25 10 is greater than 208V Most homes have 240V 1PH MS 225T 250 7 5 208 36 8 service Use 208V rated unit for 208V power 240 32 8 2 Use minimum 9o C 300V rated insulated copper M5 300T 325 an 208 RE conductors only sized in accordance with National MS 400T 375 9 0 208 44 8 Electrical Code and local electrical code for the Amps 240 38 8 in Ampere Chart If allowed by codes NM cable may MS Super IT 475 10 0 208 48 8 require a larger wire size than as listed on the chart 240 42 8 3 Connect suitably sized equipment grounding wire to MS Super 2T 575 12 0 es 20 6 proline Sem man provide MS SuPER 3T 675 15 0 208 72 6 4 Install a separate circuit breaker between supply and 240 63 6 unit Provide a power supply disconnect within sight MS Super 4T 875 20 208 2x48 8 of the steam generator or one that is capable of being 240 2x42 8 locked in the open position MS Super 5T 1075 24 208 2x58 6 240 2x50 8 5 For single phase units use two wire supply source and MS Super 6T 1275 30 208 2x72 6 equipment grounding wire Neutral white wire is 240 2x63 6 not required See page 15 for room sizing MS Sup
29. elay indicator LED is ON when relay is closed and sending 24 Volts to AutoFlush valve motor closing valve Contactor relay indicator LED is ON when relay is closed and sending 24 Volts to the contactor coil This LED comes ON after LED s DRY amp RLY WTR go OFF E 00000 QOO000000 p p p t e SaaS 380ud dW3l Xnv Enlarged Detail of LED Indicators 14 mr steam Select Your Mr Steam Installation Operation amp Maintenance Manual 1 Measure the Length Width and Height in feet of steam shower or tub shower Multiply the Length x Width x Height to get the basic room volume in CUBIC FEET a a 2 Add 15 of a for each of the following design features that describe the steambath enclosure b Each exterior wall or uninsulated attic b or crawlspace above or below ceiling or floor c Tile on mud wall porcelain tile or glass tile d An extra glass panel in addition to the door e Marble bench f Each foot exceeding 8 ft height 3 If the interior wall construction material within the steam enclosure is natural marble stone shale glass block or concrete Add Boxes a through g to optain the total cubic feet required a n Copy the figure from box a to box g 8 TOTAL CUBIC FEET REQUIRED h Compare the total cubic feet required h to the specification chart below and select the
30. empo controls Battery Replacement Your remote control is powered by two AAA batteries NOTE Before you start it s important to note that you have only 3 minutes to change batteries if you want to retain codes recorded in the memory 1 Unscrew and remove bottom cap NOTE You can use a coin to unscrew cap 2 Insert new batteries making sure to match plus ends with the plus markings on the battery case 3 Replace cap ensure the waterproof gasket is correctly positioned After replacing batteries LED indicator will flash twice indicating that programmed codes are still in memory If LED indicator flashes 3 times it means that programmed code settings have been erased reenter the code per instructions on page 23 Installing the Tempo Remote Holder A holder is provided with the Tempo Remote Control as Q an optional convenience j Mount the holder in a location away from direct steam emission Secure the holder to a wall so the TEMPO REMOTE is oriented in the upright position as shown Determine if the two screws provided are suitable for the installation conditions 4 TEMPO REMOTE Use alternate hardware or use with plastic anchors as required by installation conditions Seal screw holes in the wall against moisture as required _ HOLDER 25 mr steam steamthera py tempo controls Tempo Ext Dimensional Information The TEMPO EXT control can only be used together with a
31. er 4T includes 2 MS Super 1T units MS Super 5T includes 2 MS Super 2T units MS Super 6T includes 2 MS Super 3T units TAII specifications shown are for 208V and 240V single phase Consult factory for other voltage specifications Provide a power supply disconnect within sight of the steam generator or one that is capable of being locked in the open position as permitted by code Field Power Wiring Models MS 65T MS 400T single phase wiring shown Ground Lug Ground TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS nt Contactor NOTE FOR ILLUSTRATIVE PURPOSES edam conduit an ings ONLY CONSULT WITH QUALIFIED omit for duh LICENSED ELECTRICIAN FOR ELECTRICAL INSTALLATION Models MS Super LT 6T single phase wiring shown L1 L2 GROUND TO BE FIELD WIRED Power block Ground Ground lug Fuse 5 I Fuse block E S fg ZE By Knock out S e Pam gt con ns Yeda omitted for clarity Y C Ge Ru 2 E ant mr ste am Installation Operation amp Maintenance Manual Wiring Diagrams LEG EN D Al diagrams __ __ FIELD WIRING POWER INPUT FACTORY WIRING ul l z BLACK ITE SINGLE PHASE MS 65T MS 90T MS 150T MS 225T MS 300T MS 400T AUTOFLUSH optional FEED HEATING SOLENOID ELEMENT VAVLE CONTROL BOARD POWER INPUT 1 SINGLE P
32. er hole in the desired control location Diagram 1 Do not oversize or undersize the hole Step 3 Route the control cable provided with the control from the wall cutout to the steam generator Locate the end marked GENERATOR END at the steam generator Connect the b sguare connector to the steam genera tor connector A as shown in Diagram 2 DIAGRAM 2 NOTE The connector is keyed IMPORTANT Do not strain staple pinch or otherwise damage the control cable Route cable as reguired to permit replacement 19 mr steam ste tempo controls Installation Instructions for Tempo amp Tempo Plus Step 4 Firmly connect the connector near the CONTROL END marking to the back of the control Turn on power to the steam generator and test the control to verify correct con nections Test per the instructions on page 21 Proceed with installation and verification of proper control function IMPORTANT Turn power to the steam generator OFF before installing the control Failure to turn the power off will result in an inoperable control Step 5 Remove amp discard peel off paper to expose adhesive liner as shown in Diagram 3 Step 6 Run a bead of silicone provided as shown to the C shaped groove as shown in Diagram 4 IMPORTANT Do not apply excessive amounts of silicone Do not apply silicone to any other parts of the control including the adhesive gasket Step 7 Insure the mounting surface is cle
33. er instructions on pg 6 Steam emission slot mr steam Installation Steam Head 72 NPT INSTALLER Because the steam head and direct steam emissions are very hot locate the steam head where incidental contact by bather with the steam head or direct steam emission cannot occur STEP 1 Locate steam head 6 12 inches above floor except for Tub shower enclosures install 6 inches above tub top edge For enclosures with acrylic or other non heat resistant flooring install Acrylic Shield Part Number MS 103938 STEP 2 Install steamhead with the oil well facing up as shown Hand tightening is sufficient when teflon or equal pipe thread seal ing compound is used IMPORTANT NOTE to preserve steam head finish do not use wrench or other tools to tighten Use no abrasive cleansers or chemicals Use only water with mild soap and a non abrasive sponge Consult with supplier of acrylic fiberglass and other non heat resistant enclosures for recommended steamhead location Use Acrylic Shield part number MS 103938 See instructions provided with steam shield STEP 3 Secure a bronze drop ear fitting to a header and run a 1 2 copper steamline from the steam generator to the drop ear fitting Install a temporary nipple 6 or longer in the drop ear fitting to locate the steamhead after the wall is finished STEP 4 After the wall has been finished mark on the nipple where the sur face of the wall is Remove the nipple and measur
34. fud C PUR 101289A Rev 9 3 07 eo Table of Contents Before Installing aos Sch aka uer d xb awe wy ee eats 2 SteamRoomGuidelines 2 Locating the Steam Generator Unit 25e eres 3 Typical Installation scales dam Sauce Deren Aba li 3 MS Super 4T 5T 6TTypicalinstallation A Installation Plumbing Water Supply Steam Outlet Drain Safety Valve 5 Using Aromasteam Essential Oils 5 Steam Head Installation 6 GeneratorDimensions 0 0 5 7 Electrical Specifications iii qoi b ik Baki 8 Field Power e sa SP e e e to esta NEME s reco eee seen 8 Wiring Diagrams Sos aos e aa ea ee aes 9 11 Optional Tandem Cable nnn okay a aya 12 Initial Start Up and Checkout oed 9 9 fik 12 Maintenance 0 000 12 OptionalAutoFlushSystem 13 Liquid Level Control Bodid c esos ascen 14 SelectYourMr StemModel 15 Replacement Parts Diagram isse RE hn 16 Replacement Parts Listes ive cakes Nat cn CR s 17 Tempo Controls General Information amp Carelips 18 SafetytrOperatinginformation 18 TEMPO amp TEMPO PLUS Installation instructions 19 20 TEMPO Operating Instructioris 2e ee rre me nena 21 TEMPO PLUS Operatinginstructions 22 TEMPO REMOTE Programming the Code s bp
35. h a TEMPO PLUS Control and a matching AromaSteam steam head MS SUPER 4T includes two MS SUPERAT steam generators two matchi MS SUPER generators two matchi MS SUPER generators two matchi and one TEMPO PLUS Control and ng AromaSteam steam heads 5T includes two MS SUPER 2T steam and one TEMPO PLUS Control and ng AromaSteam steam heads 6T includes two MS SUPER 3 steam and one TEMPO PLUS Control and ng AromaSteam steam heads MS 65T MS 4ooT weighs 47 lbs MS SUPER Call for ava and phases 1T MS SUPER3T weighs 7olbs ilability of additional voltages mr steam stea mthera Dy Installation Operation amp Maintenance Manual MS Regular Models MS65T MS400T with AutoFlush shown with cover removed Liqu NOTE FOR ILLUSTRATIVE PURPOSES ONLY Some components may be omitted or altered for clarity Do not use for wiring repair or other purposes not related to component identification Power Block Power Supply Knock Out id Level Probe Access Cover Heating Element Stainless Steel Tank Liquid Level Control Board Data Plate Transformer _ Water Feed Solenoid Water Feed __ J Plug and Play Connection see page 14 Water Feed Hose AutoFlush Valve optional NOTE valve shown in open position as required for operation with autoflush Drain Line MS Super Models MS
36. ield installed ield installe water supply pipe Pd IMPORTANT See page 19 i for steam head and control AA location information Field installed d el Steam generator e A _ Valve should be PX Provide unions as required to facilitate closed when AutoFlush installation and disconnect of piping is not installed feam Head shown with optional acrylic shield See page 6 for Steam Head Installation information in ARES x mr ste am s C ID Installation Operation amp Maintenance Manual MS Super 4T 5T 6T Typical Configuration Installation Instructions for Models Diagram A MS Super 4T MS Super 5T and MS Super 6T i Install each steam generator as in a single installation Printed Circuit Board Install generators as close as practical to each other Component shown not exceeding 12 feet The interconnecting cable length is purpose 12 feet 2 IMPORTANT NOTE Power must be disconnected at the main electrical supply Remove steam generator covers Retain screws and covers for reuse 3 Connect the TEMPO PLUS control to either unit per instructions supplied with the TEMPO PLUS control see pages 19 28 4 Remove one knock out on each generator as shown Insert the ends of interconnecting cable provided PN 103904 through the knock outs as shown in Diagram A Connect each end to the printed circuit board connector labeled TANDEM as shown 5 Prevent the interconnecting cable from
37. oa etes BY ge ane ene 23 Using the Remotes cos tbe tr RAM ekim 24 Pa sine th Unites renina a UR ran Oe qu 24 Setting Program Values gi yene ek ba wan ou eR e vl 24 Battery Replacement a tnd don and a aat Nd 25 Installing the Heldekes a AeA e a nl Ve Ear uos 25 TEMPO EXT Using the TEMPO EXT dua e ar GE Ade ee ra 26 InstallingtheTEMPO EXTcontrol 26 Installing the MSTS Remote Temperature Probe 27 28 mr steam gt mr ste am Installation Operation amp Maintenance Manual Before Installing IMPORTANT The following general information should be used in conjunction with consultations with your architect designer and contractor in determining all factors necessary in providing a suitable and safe steam room Read these instructions before installation or service Although this MS steambath generator has been fully qualified for ship ment by MrSteam the following must be reviewed for proper safe and enjoyable steam bathing Verify that the model and accessories are correct including incoming line voltage Insure steambath generator has been correctly sized for the steambath room Pay particular attention to room volume and construction If any questions please refer to MrSteam sizing guide enclosed see page 15 Marble or glass walls or ceilings or exterior walls ENLARGE the room s size requiring a generator larger than one based only on the room s cubic foot L x H x W volume The physic
38. ontrol 60 ft All models MSTS Remote Temperature Probe All models 100476 2 Contactor 50A 2 pole MS 65T 400T Single phase 99012 Contactor 50A 3 pole All 3 Phase models 103453 Contactor 50A 4 pole MS Super 1T Super 6T 100471 2 Probe Assembly All models 99096 MS Heating Element Gasket All models MS 103938 Acrylic Shield All Models 99314 Power Fuse 60A 250V MS Super 1T 6T Single phase 29041BMS Heating Element 4 5 KW 208V MS 65T 29041CMS Heating Element 4 5 KW 240V MS 65T 29051BMS Heating Element 5 KW 208V MS 9oT 29051CMS Heating Element 5 KW 240V MS 9oT 29061BMS Heating Element 6 KW 208V MS 150T 29061CMS Heating Element 6 KW 240V MS 150T 29071BMS Heating Element 7 5 KW 208V MS 225T 29071CMS Heating Element 7 5 KW 240V MS 225T 29081BMS Heating Element 8 5 KW 208V MS 300T 29081CMS Heating Element 8 5 KW 240V MS 300T 29091BMS Heating Element 9 KW 208V MS 4001 29091CMS Heating Element 9 KW 240V MS 4001 29101BMS Heating Element 10 KW 208V MS SUPERAT amp MS Super 4T 29101CMS Heating Element 10 KW 240V MS SUPERAT amp MS Super 4T 29121BMS Heating Element 12 KW 208V MS SUPER 2T amp MS Super 5T 29121CMS Heating Element 12 KW 240V MS SUPER 2T amp MS Super 5T 29151BMS Heating Element 15 KW 208V MS SUPER 3T amp MS Super 6T 29151CMS Heating Element 15 KW 240V MS SUPER 3T amp MS Super 6T 17 mr steam tempo Care Tips for all Controls 1 Use only mild soap and water on a soft cloth to clean the control 2 Do not use ab
39. po Ext control wiring inside con duit together with power lines or close to hot water or steam piping Doing so may result in an inoperative or hazardous installation Do not alter or modify Tempo Plus Tempo Tempo Ext or Tempo Remote controls Doing so may result in an inoperative or hazardous installation IMPORTANT NOTES Turn power to the steam generator OFF before installing the control Failure to turn the power off will result in an inoperable control If a Tempo Plus control is to be used with a Tempo Remote control the Tempo Plus must be in located for line of sight operation with the Tempo Remote control See the Tempo Remote operating instructions before installation of the Tempo Plus control Do not operate Tempo Plus Tempo Tempo Ext or Tempo Remote controls with other than a Mr Steam Tempo compatible steam generator Mr Steam residential steam generators with serial numbers lower than 355500 or any other brand of steam generator are not to be operated with TEMPO controls Doing so may result in an inoperative installation This document contains important safety operation and maintenance information Leave this document with the homeowner Do not discard this document Discontinue use of the steam generator or control if the steam generator is damaged or otherwise not functioning properly Doing so may result in an inoperative or hazardous installation 18 controls mr Steam s tempo controls Inst
40. rasive cleansers 3 If the decorative cover is damaged on the TEMPO or TEMPO PLUS call Mr Steam technical service for replacement parts Safety and Operating Information Turn power to the steam generator OFF before installing the control Failure to turn the power off will result in an inoperable control Do not install or use any Tempo Plus Tempo Tempo Ext or Tempo Remote controls without reading and understanding the Mr Steam steam generator Installation and Operation Manual PN 101289 Revision number 7 5 05 or higher Failure to read and understand these instructions may result in an inoperative or hazardous installa tion A peel and stick warning is provided with the Mr Steam steam generator Installation and Operation Manual Mr Steam strongly recommends that this warning be read and posted in a conspicuous location near the steam room Install the Tempo or Tempo Plus controls according to installation instructions Failure to install according to instructions will result in an inoperative control or hazardous overheating or inadequate heating of the steam room If a Tempo or Tempo Plus control is installed outside the steam room a Remote Temperature Probe PN MSTS must be installed inside the steam room per installation instructions sup plied with the Remote Temperature Probe Failure to install according to instructions will result in an inoperative control and overheating of the steamroom Do not route Tempo Plus Tempo Tem
41. red for servicing Alternately provide unions as required to facilitate installation and disconnection of the steam generator IMPORTANT NOTE The minimum clearance from combustible sur faces is zero all around IMPORTANT NOTE Do not rough in plumbing and electrical services based in the dimensional information provided Drawings are not to scale m ak 4 T J dnltr ce ce o esa F SE M G I Side View Showing Element Access Panel MS 65T MS 400T MS SUPER 1T 6T l A 51 2 140 71 4 184 B 83 4 210 10 254 i C 17 8 302 1234 2 310 I i D 143 4 375 18 3 4 466 i E 13 4 45 6 152 i F 17 8 48 24 2 64 i G 31 2 89 4 102 E H 5 127 6 152 l 63 4 171 77 8 200 J 33 4 45 13 8 35 K 141 2 368 193 4 502 L 24 2 64 23 8 60 M 6 152 63 8 162 NOTES TO AVOID EQUIPMENT DAMAGE DO NOT CONNECT POWER SUPPLY DIRECTLY TO ELEMENTS NOTE FOR ILLUSTRATIVE PURPOSES ONLY 1 M Optional AutoFlush 2 All units in inches MM 3 MS Super 4T includes 2 MS Super 1T units 4 MS Super 5T includes 2 MS Super 2T units 5 MS Super 6T includes 2 MS Super 3T units On 4 NON a mr ste am stea ciap Installation Operation amp Maintenance Manual Electrical AMPERE CHART MODEL NO MAX ROOM KW VOLTS AMPS WIRE SIZE All electrical wiring to be installed by a qualifi
42. roughly before making connection to unit 5 Strainer recommended upstream of feed water connection 6 For best performance water pressure should be 15 to 20 psig Reduce pressure as required if necessary 7 Provide anti water hammer device as required 8 As required by local codes install an approved backflow preventer Drain NPT NOTE A drain valve is provided to facilitate servicing Provide a drain line connection from steambath generator drain valve according to National and local Codes Check local plumbing code for receptor trap and vent requirements Unit drains by gravity Using Mr Steam Essential Oils Installation Operation amp Maintenance Manual Steam Outlet NPT 1 Do not install any valve in steam line Flow of steam must be unobstructed 2 Use 1 2 inch brass pipe or copper tubing from unit to steam head as permitted by codes 3 Insulate steam line using pipe insulation rated 250 F or higher 4 Pitch steam line 1 4 per foot towards steam head or steam genera tor to avoid valleys and trapping of condensate NOTE Running the steam line down and then up will create a steam trap blocking the flow of steam NOTE A 1 5 hole in the steamroom is required to mount the steamhead Safety Valve 34 NPT Where permitted by local codes provide an outlet plumbing connection for safety valve JAR War NING To insure proper and automatic safety valve operation DO NOT connect a shut off valve
43. tting Use the UP and DOWN keys to change the tempera ture setting from 105 F to 120 F in one degree increments Set the steambathing temperature according to personal preference however it is highly recommended to begin steambathing at a low tem perature setting to gauge comfort and safety levels Timer Feature When the control is turned ON a 60 minute time duration is initiated The control will turn off after 60 minutes unless the control is turned off manually Memory Feature If the control is turned off manually before 60 minutes then the default temperature of 110 F will be used the next time the control is DIAGRAM 2 turned on If the control times out at 60 minutes not manually turned off then the previous user temperature setting will be used when the steambath is used again DIAGRAM 3 21 mr steam steamtherapy Tempo Plus Operating Instructions The TEMPO Plus Control features programmable digital temperature control pro grammable time duration ON OFF and PAUSE and two personal settings storage ON OFF Diagram 1 Press the ON OFF key to start or stop the flow of steam Steam will begin to flow a few minutes after the control is turned ON The dura tion required for the steamroom to reach steambathing temperatures depends on the steamroom construction and steam generator specifications Steam may con tinue to flow for a short time after the control is turned OFF PAUSE Feature Diagram 2 If
Download Pdf Manuals
Related Search
Related Contents
MV-370 / MV-372 VoIP GSM Gateway User Manual PORTech Biacore X100 Plus Package 取扱説明書 INSTRUCTION MANUAL Manual del Usuario Casio Watch MA1106-EA User's Manual BA 2012 1 E BMB Hama 00118622 flat panel floorstand Philips Sonicare ProResults HX6012/02 brushhead Benefícios de uso Material necessário Cuidados Copyright © All rights reserved.